March, 2017 Nova Scotia On-site Sewage Disposal Systems Standard revisions effective May 1, Appendix C Falling head permeameter

Similar documents
NS On-site Sewage Disposal Systems Technical Guidelines: Summary of Changes January 2013

INYO COUNTY ENVIRONMENTAL HEALTH SERVICES RESIDENTIAL ONSITE SEWAGE TREATMENT AND DISPOSAL GUIDE

APPENDIX E SELECTION EXAMPLE

Common Septic System Installation Mistakes

Geotextile Sand Filter

Holding tank Interceptor Leaching Leaching bed Leaching bed fill Loading rate Pail privy Percolation time Portable privy Potable Pressurized

NORTH CAROLINA DEPARTMENT OF HEALTH AND HUMAN SERVICES DIVISION OF PUBLIC HEALTH ENVIRONMENTAL HEALTH SECTION ON-SITE WATER PROTECTION BRANCH

ON-SITE SEWAGE CONTRACTOR EXAMINATION STUDY GUIDE

Commonwealth of Massachusetts City/Town of Septic System Installation Checklist

Sewage System Installation Proposal

THIS IS A COURTESY COPY OF THIS RULE. ALL OF THE DEPARTMENT S RULES ARE COMPILED IN TITLE 7 OF THE NEW JERSEY ADMINISTRATIVE CODE.

ON-SITE SEWAGE PERMITTING PROCESS

Wastewater treatment for single houses. D. O Dowd

Unit 1 - Introduction, Testing Criteria, and Design Criteria 1-1 Introduction 1-2 Testing Criteria Requirements 1-3 System Design Requirements

GRAYWATER STANDARD PLAN For Simple Residential System

AS/NZS 1547:2012 and AS/NZS 1547:2000 On-site Domestic Wastewater Management CONTENTS COMPARISON [PART A: AS/NZS 1547:2012 LISTED ORDER]

AS/NZS 1547:2012 and AS/NZS 1547:2000 On-site Domestic Wastewater Management CONTENTS COMPARISON [PART B: AS/NZS 1547:2000 LISTED ORDER]

Unit 1 - Alternate Peat Based Systems In Pennsylvania Unit 2 - Alternate Peat Based System Option 1 Unit 3 - Alternate Peat Based System Option 2

City of Vineland Health Department 640 E. Wood Street, Vineland, NJ (856) (ph.) / (856) (fax)

Water Quality Control Division Engineering Section On-site Wastewater Treatment Systems

APPENDIX B SAND MOUND

I. Preconstruction Meeting and Site Preparation Date: Inspector: A. MDE Certified Installer Name

Complex Sewage Disposal Course 2017

The exam is enclosed with this correspondence. This test emphasizes standard requirements for installing gravity-fed septic systems.

The exam is enclosed with this correspondence. This test emphasizes standard requirements for installing gravity-fed septic systems.

Woodford County Health Department 1831 S. Main Street, Eureka, IL Phone: (309) Fax: (309)

GUIDELINES FOR SEPTIC SYSTEM DESIGN

NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES DIVISION OF ENVIRONMENTAL HEALTH ON-SITE WATER PROTECTION SECTION

BURLINGTON COUNTY HEALTH DEPARTMENT 15 PIONEER BOULEVARD, WESTAMPTON PO BOX 6000 MOUNT HOLLY, NEW JERSEY 08060

APPENDIX 5 On Site Sewage Treatment and Disposal 1. Site Requirements

Commonwealth of Pennsylvania Department of Environmental Protection (DEP) Bureau of Water Standards and Facility Regulation Harrisburg, PA

GRAY WATER SYSTEMS FOR RESIDENTIAL BUILDINGS

Manual - Part 2 - Materials

Schedule 2A: Sewage System Information

GRAYWATER SYSTEMS FOR RESIDENTIAL BUILDINGS

On-Site Wastewater Disposal Site Assessment, Subsoil Investigation and Site Evaluation Checklist

GRAY WATER RECYCLING SYSTEMS

NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES DIVISION OF ENVIRONMENTAL HEALTH ON-SITE WASTEWATER SECTION

PARK COUNTY STAFF REPORT On-Site Wastewater Treatment System Regulation Update Public Hearing. Sheila Cross, Director of Development Services

Work Sheet #6 Assessing the Risk of Groundwater Contamination from Household Wastewater Treatment

130A-343. Approval of on-site subsurface wastewater systems. (a) Definitions. As used in this section: (1) "Accepted wastewater dispersal system"

GUIDELINES FOR INSTALLATION OF ON-SITE SEWAGE SYSTEMS

REQUIRED SEPTIC DRAWINGS

Klickitat County. On-Site Sewage System. Construction Manual

Section 9: Sand Mounds. 9. Sand Mounds

Sewage System Inspection Requirements and Reporting Form Rondeau Provincial Park Cottage Lot Program

CERTIFYING DRAINLAYER

Private Sewage Systems Standard of Practice Proposed Revisions

PROCEDURES FOR APPLICATION FOR APPROVAL OF PRIVATE SEWAGE DISPOSAL SYSTEM CONSTRUCTION. January 1, An Interim Document

Sewage System Inspection Requirements and Reporting Form Algonquin Provincial Park Cottage Lot Program

San Joaquin County. Residential Onsite Systems Bulletin

Mono County Health Department Construction Guide for Residential and Commercial On-Site Sewage Treatment & Disposal System I.

INSTALLING A SEPTIC SYSTEM IN LIVINGSTON COUNTY LIVINGSTON COUNTY PUBLIC HEALTH DEPARTMENT 310 TORRANCE AVENUE PONTIAC, IL /

Sewage Permit Process Backgrounder and Guide

GRAY WATER SYSTEMS (Reference California Plumbing Code Chapter 16 and 16A) Revised: 6/11/14

APPENDIX A LOW PRESSURE DOSED SAND FILTERS

EVALUATION OF GRAVELLESS PIPE SYSTEMS FOR ONSITE WASTEWATER TREATMENT ACROSS MINNESOTA

REGISTRATION EXAMINATION, NOVEMBER 2012 LICENSED DRAINLAYER QUESTION AND ANSWER BOOKLET. Time allowed THREE hours

DRIP EMITTER SYSTEM STUDY GUIDE

For use by Principal Authority. A. Project information Building number, street name Unit number Lot/con.

Geotextile Sand Filter

PART 8 SEWAGE SYSTEMS. Section 8.1. General Scope Application Limitations

Design Solutions: Dealing With New Code Issues

City of Malibu Stuart Ranch Road Malibu, California Phone (310) Fax (310)

SUPPLEMENT EXISTING SEPTIC SYSTEM INSPECTION REPORT WHO IS QUALIFIED TO PERFORM AN INSPECTION?

Section 8: Amended Soil Mounds. 8. Amended Soil Mounds

EXISTING SEPTIC SYSTEM INSPECTION REPORT CONNECTICUT RECOMMENDED MINIMUM

AOWA:Basic Installer Course 1

City of Malibu Stuart Ranch Road Malibu, California Phone (310) Fax (310)

COMMONWEALTH OF MASSACHUSETTS EXECUTIVE OFFICE OF ENVIRONMENTAL AFFAIRS DEPARTMENT OF ENVIRONMENTAL PROTECTION

CERTIFICATE OF APPROVED REGISTRATION J. T. BAKER CHEMICAL COMPANY. Sanitary Landfill. Harmony Township. Warren 2110B

Contactor & Recharger Septic Chambers

Producer Statement. Design: On-Site Effluent Disposal Systems (AS/NZS 1547:2012)

WHAT TO CONSIDER IN CHOOSING A SYSTEM

***NO SEPTIC SYSTEM EXCAVATION WITHOUT AN APPROVED PERMIT IN POSSESSION****

SEWAGE SYSTEM PERMIT GUIDELINES

Massachusetts Design & Installation Manual

Contact Information Owner s Name Home Phone Cell Phone Mailing Address City Zip Code

Section 8 Minimum Horizontal and Vertical Setback Distances

CERTIFYING DRAINLAYER

Contact Information Owner s Name Home Phone Cell Phone Mailing Address City Zip Code

Prestige Home Inspection LLC Propery Inspection Report Cover Page

Land Use Office, PO Box 197, 6683 County Road 13, Conejos CO Phone #: Fax:

Application for a Sewage System Permit

Source of Pollution or Groundwater Solution?

Name: Company: Address: Telephone: PEI Cert. #

PRODUCER STATEMENT SYSTEMS (T.P.58) DESIGN: ON-SITE EFFLUENT DISPOSAL

Alteration/Expansion or Change in Use Alteration/Malfunctioning System Deviation from Standards Repairs to Existing System

ACCESS RISERS & EFFLUENT FILTER

Pump Tank and Pretreatment Inspection & Troubleshooting. Sara Heger University of Minnesota

FILED 11/01/2017 2:05 PM ARCHIVES DIVISION SECRETARY OF STATE

Permeable Pavement Facilities and Surfaces

TABLE 1 OAR MINIMUM SEPARATION DISTANCES

Indiana Standards for Secondary Treatment Systems. Table of Contents

Private Sewage Permit Application

CONNECTICUT PUBLIC HEALTH CODE. On-site Sewage Disposal Regulations and Technical Standards for Subsurface Sewage Disposal Systems

CHAPTER IX RULES AND REGULATIONS FOR GRINDER PUMPS. A. "Department" means Concord Township Sewer Department.

Wetlands Application. Constructed Wetlands

PERC-RITE DRIP DISPERSAL DESIGN GUIDE FOR SEPTIC TANK OR ADVANCED TREATMENT EFFLUENT MASSACHUSETTS

Section 10 Design Criteria: Components

Transcription:

Table of contents Appendix C Detailed Cross drawings Appendix D Falling head permeameter Appendix C Falling head permeameter Appendix D Detailed Cross drawings Reduce confusion related to appendix C labeling. Contour trenches are C1, C2, C3 and were previously Appendix C, this created some confusion. 1 &2 (1) This Standard describes the minimum requirements for selection, design, and installation of an on-site sewage disposal system or its parts. (2) The repair or alteration of an existing on-site sewage disposal system must be carried out by a certified installer in accordance with this Standard. (1) This Standard applies only to the requirements for an on site sewage system which handles sewage that is composed primarily of human waste and grey water from bathrooms, sinks and kitchens but not does include any significant volume of wastewater from an industrial source. (2) This Standard describes the minimum requirements for selection, design, installation, repair and alteration of an on site sewage disposal system, or its parts. This change clarifies the applicability of the Standard that does not include industrial wastewater. Any on-site sewage system for the treatment of industrial wastewater would require an approval from NSE. 2 (1) Relies on definition of adverse effect in Act. Addition of definition (matches Act) "adverse effect" means an effect that impairs or damages the environment or changes the environment in a manner that negatively affects aspects of human health; Clarifies wording related to a malfunctioning system. 1

2 (1) Building sewer line defined Building sewer line definition removed Building sewer line is not considered part of the on-site sewage system as it is captured under the Building Code Regulations and National Plumbing Code. This change will clarify the scope of the Standard. 2 (1) Terms were not previously defined distribution trench means the highly porous section of a system that is level, typically consists of aggregate surrounding perforated pipe, or arch-shaped chambers, and spreads effluent from a septic tank or ATU across the length of the disposal field; impervious geomembrane means a very low permeability synthetic liner or barrier intended for use within subsurface soils to control fluid migration; malfunction means a release of untreated or partially treated sewage that causes or may cause an adverse effect; selected system means a system chosen according to the specifications in Appendix A of the Standard; soil effective depth means the depth of Improves clarity and intent of existing wording throughout the Standard. 2

unsaturated permeable soil beneath the organic layer minus the depth of soil required to prevent saturation above the invert distribution pipe; 3 (1) residential applications The term applications was replaced with use throughout the Standard Clarifies intent and confusion related to applications for approval Table 1 Table 2 Addition of terms base flow and additional flow and text additional flow can only be used in addition to base flow. Addition of 0.6 m vertical clearance requirement for a distribution trench receiving treated effluent from an Advanced Treatment Units (ATUs). Addition of descriptors (water-tight and nonwater-tight portion of system) and more inclusive list of system components. Clarifies intent of flow determination for selected systems Applies consistency to all approved ATUs: some ATUs were granted permission for reduced vertical clearance previously, this change will treat all ATUs the same. Improves clarity and applicability of clearance distance requirements. 4(2) Addition of reference to ATU in description of where clearance distances are measured from. Improves clarity. 4(3) Water tight, impervious membrane Reference to system components Changed to water-tight & impervious geomembrane Reference to system components changed to water-tight portion of system. Improves consistency, clarity and intent. 3

5(5)a..examine at least one test pit Addition of, at the proposed distribution trench location Improves clarity and intent. Table 3 Errors in hydraulic conductivity ranges Errors corrected Improves clarity. 5(6)b..total soil depth requirements Addition of reference to term D as required by system selection tables. Improves clarity. 5(8) NA A professional engineer must do one of the following: (a) select or design a system that uses a soil type with a permeability class of Acceptable as set out in Table 3; (b) design a system that uses a soil type with a permeability class of Low as set out in Table 3 if the system meets the requirements of the section of this Standard titled Advanced on-site sewage treatment technologies. 8 & 9 The riser cover must be a minimum of 100 mm above deleted Riser must meet all of the following; Addition of Allows professional engineer to use their own judgement and expertise related to soils used in system design. Clarifies intent and addresses complaints from industry and 4

finished grade and installed so that the area around the cover is graded to divert surface drainage. 8(d) it must be visible to provide ease of location. The riser cover must be at or above finished grade and installed so that the area around the cover is graded to divert surface drainage. landowners related to requirement of riser 100mm (4 ) above finished grade. Table 4 Table 4 & S. 11 No design requirements for septic tank capacity for systems with high flows (greater than 5 bedrooms not captured by Table 4) 11 added, Septic tanks for uses not listed in Table 4 must have a minimum capacity of at least 2 times the average daily flow. Clarifies intent, standard design requirement for system design. Covers situations not captured by Table 4. 19 20 An effluent chamber must have sufficient discharge capacity to distribute effluent over the entire length of the distribution trench and fill the distribution pipe during each dose. An effluent chamber must have sufficient discharge capacity to spread effluent equally over the length of the distribution trench during each dose. Minor wording revisions to improve clarity and intent. & 20 & 21 A pressure-fed system must have a dosing frequency of at least two times per day. A pressure-fed system must be selected or designed to have a dosing frequency of at least two times per day. 21 NA A pump chamber must provide liquid storage capacity equal to one day s flow. deleted, relies on Table 5 for selected systems. Allows professional engineer to design a system with various pump chamber capacities to meet site specific needs. 5

Table 5 Added to table title, for selected systems Clarifies applicability of Table 5 for selected systems only, allows professional engineer some design flexibility. 29 NA Building sewer line section deleted, relies on Building Code Regulations & National Plumbing Code requirements. Clarifies applicability of Standard 30 29 (1) Crushed rock or gravel in a distribution and interceptor trench must be washed, screened, and free of fine material. (2) Ninety-eight percent by weight of the crushed rock or gravel in a distribution and interceptor trench must be able to pass through a 35 mm screen and unable to pass through a 12 mm screen. Term washed was changed to clean. Reference to interceptor was deleted. Clarifies intent and allows qualified person or professional engineer to specify any aggregate for the interceptor trench (aggregate is not required to meet distribution trench specifications). Figure 1 Error in angle of hole reference Error was fixed to consistently reference 60 from invert Improves consistency and clarity 38 37..reference to Figure 1 related to Addition of reference to vent holes as illustrated Improves clarity 6

hole spacing in Figure 1. 40 39 Maximum particle size of 10mm Changed to 25mm as intention is to reflect absolute max particle size. Relies more on subsections (2) & (3) related to the hydraulic conductivity of the sand as determined by the falling head permeameter test. 43 42 An interceptor trench must meet all of the following: (a) it must be at least 300 mm in width and filled with aggregate that conforms to the requirements of 30 of this Standard; Reference to aggregate specifications removed to align with previous revision. Saves existing sand manufacturers time and money by allowing them to continue using same equipment provided sand passes permeameter test. Clarifies intent and applicability of Standard. Allows flexibility in aggregate used in interceptor trench. 44 & 45 43 & 44 Impervious liner Changed to impervious geomembrane to be consistent with previous wording. Improves consistency, clarity and intent. 46 45 impervious liner referred to in 45. must meet all of Sub-section (a) deleted Relies on definition of impervious geomembrane and improves clarity. 7

the following.. (a) it must be a 20 mil HDPE or LDPE geomembrane with all seams overlapped a minimum of 0.3 m with an appropriate sealant between the overlap; (a) it must be installed along the bottom of the interceptor trench; (b) it must be installed up the entire vertical face of the downslope side of the trench. (b) it must be installed along the bottom of the interceptor trench; (c) it must be installed up the vertical face of the downslope side of the trench 52(2) 51(2)..lowest hydraulic conductivity Changed to lowest acceptable hydraulic conductivity Improves clarity and intent. 61 NA Flow equalization must be included as part of the ATU or be incorporated into the system design. NA 73 Clause missing related to design flow associated with a malfunction replacement removed as most ATUs include flow equalization if required. Addition of If it is not possible to meet clearance distances specified in 4, system design capacity must be less than or equal to the design Relies more on professional engineer designing the system and the ATU design manual specifications. Clarifies intention that if a professional engineer is designing a malfunction replacement system and is unable to maintain all clearance distance 8

system. capacity associated with the existing conditions. requirements, that an increase in design flow would not be permitted under the notification process (in previous technical guideline). 75 74 A professional engineer must consider site specific conditions and incorporate protective measures in the system design to ensure that the repair or replacement will not cause an adverse effect to the environment or human health. A professional engineer must consider site specific conditions and incorporate protective measures in the system design to ensure that the repair or replacement will not increase the risk of an adverse effect. Simplifies language and clarifies intent related to risk of adverse effect. Appendix C-5 through C-9 Appendix D-5 through D-9 Minimum depth of sand below distribution trench missing. Addition of -600mm min depth of sand below distribution trench reference in cross section diagrams for C3 and Mounds. Clarifies intent and previous requirement from technical guidelines. 9