Investigation of Photovoltaic Self-sufficiency for a Residential Building in Canada

Similar documents
Solar Power. Technical Aspects and Environmental Impacts. 6 th March 2011 Sustainable Energy Options (UAU212F) - University of Iceland

SOLAR ENGINEERING OF THERMAL PROCESSES

A Case Study on the Daylighting and Thermal Effects of Fixed and Motorized Light Louvers

Energy Simulation And Optimized Retrofit Practices Applied To A Real Dwelling

ANALYSIS AND MITIGATION OF THERMAL EFFECTS ON A LARGE FACADE-MOUNTED PV ARRAY

COMPARISON OF ENERGY USE INDICATORS OF A NON-RESIDENTIAL PASSIVE HOUSE WITH ASHRAE 90.1 BUDGET BUILDING

The Role of Roof Shapes in Design of Green Building Systems (Case Study: Iran, Tehran)

Digging Deeper SOLAR ENERGY. Forms of Solar Energy

Performance analysis of a PV driven heat pump system during a heating season in high latitude countries

THERMAL ANALYSIS OF A FACADE-MOUNTED PV ARRAY

Compactness ratio : 1.2. Openings ratio : 26% (thermic envelope / inhabitable area) Smaller is better 1.9 = bad < 0.8 = good

Transient Performance Analysis of a Model Building Integrated with a Trombe-Wall

SOLAR PHOTOVOLTAIC ENERGY

THE IMPORTANCE OF THERMAL MASS IN PREDICTIVE CONTROL CASE STUDY: A ZONE WITH FLOOR HEATING AND A CHILLED BEAM

AR No. # - Install Photovoltaic Array

Feasibilty of Wind-Solar Hybrid System for Cleveland, Ohio, USA

Long-term monitoring and smart heat pumps for nzeb

Fact sheet. Photovoltaic systems. Why consider photovoltaics?

AR No. # - Solar Thermal

A study for an optimization of a hybrid renewable energy system as a part of decentralized power supply

Performance Analysis of PV Solar Power System

SOLAR PHOTOVOLTAICS Part 1

DETERMINING THE OPTIMUM ORIENTATION OF A GREENHOUSE ON THE BASIS OF THE TOTAL SOLAR RADIATION AVAILABILITY

Available online at ScienceDirect. Energy Procedia 91 (2016 )

Investigating the Shading Impact of Rail on the Energy Output of a PV System in Hong Kong

Environmental concerns/reduce carbon emissions Save money on electric bills General interest in new technologies Increase in building value

Thermal Performance of Solar Heating System with Water Floor

FUNDAMENTALS OF SOLAR ENERGY

Solar Energy Technologies

Solar Energy Modeling for Residential Applications

ANNUAL ENERGY PERFORMANCE OF SOLAR THERMAL SYSTEMS IN BRAŞOV, ROMANIA

Applications of ECOTECT and HEED in building energy analysis - Case study: A typical tube house in Hanoi

An enhancement of the daylighting from side-window using two-section venetian blind

Zero Energy Home (ZEH) Project

Introduction of Heat Insulation Solar Glass

Some Performance Results and Lessons Learned from EQuilibriumTM Housing Monitoring Avalon Discovery 3

A Linear Data-Driven System Identification Methodology for an Active/Passive Solar Thermal Storage System and Application to a Solar House

JOTUN Cool Shades. Impact of the TSR Value on the Users Comfort and the Energy Performance of Buildings. ai³ Werner Jager

Performance Evaluation of an Integrated Hybrid Photovoltaic/Thermal (PV/T) Greenhouse

Effects of Fixed and Motorized Window Louvers on the Daylighting and Thermal Performance of Open-Plan Office Buildings

Achieving the nearly zero energy building concept - A study based on practical experience

FEASIBILITY OF LOW-RISE NET-ZERO ENERGY HOUSES FOR TORONTO

Conversion Design of Solar Houses from Active to Passive

Photovoltaic. - it is the main energy source of the planet since its inception 4 billion years ago and another 4 billion years it will be

AN EFFECTIVE STUDY ON PERFORMANCE ANALYSIS OF GRID CONNECTED PV SYSTEM

Comparison of Experimental and Theoretical Output Power of Grid Connected Photovoltaic System in Super Mega Factory

Consumer Energy Tax Credit

Student Modeling Competition

AR No. # Solar Thermal. Assessment Recommendation Savings Summary Source. Cost Savings Natural Gas. $984 * 1 MMBtu = 1,000,000 Btu

PASSIVE HEATING STRATEGIES. Ball State Architecture ENVIRONMENTAL SYSTEMS 1 Grondzik 1. Natural Solar

Chapter 7. Passive Solar Contents

Advanced Design and Building Information Modeling February. Would you like to develop a BIM model of this project? no

BUILDING DESIGN AND THERMAL INERTIA: WHEN, WHY, WHERE

The effect of shading design and control on building cooling demand

Optimization of Thermosiphon Solar Water Heating systems working in a Mediterranean Environment of Cyprus

Passive Strategies and Low-Carbon Technologies: Evaluating the Energy Performance and Thermal Comfort of a Passive House Design

Field Observation of Cooling Energy Savings Due to High-Reflectance Paints

BY HARNESSING THE POWER OF THE SUN WE ARE ABLE TO PRODUCE HOT WATER AND ELECTRICITY FROM AN INEXHAUSTIBLE SOURCE WITHOUT ADDING TO THE CARBON LEVELS

St Loyes Extra Care Facility PHPP Pre-Assessment Report

COMPARISON OF THERMAL PERFORMANCE OF DIFFERENT WALL STRUCTURES

Solar-Assisted Space Heating of a Highly Insulated Energy Efficient House

Rooftop Solar PV System Designers and Installers. Training Curriculum. APEC Secretariat

Case study of increasing photovoltaic energy solar fraction in a conventional office building in northern latitudes

Demonstration of Load Shifting and Peak Load Reduction with Control of Building Thermal Mass

Effect of Building Shape And Neighborhood Design On Solar Potential And Energy Performance

White Paper ENVELOPE-FIRST APPROACH TO NET-ZERO ENERGY BUILDINGS

Green Star Design & As Built Submission Template

An Investigation of Energy Efficient and Sustainable Heating Systems for Buildings: Combining Photovoltaics with Heat Pump

UT Zero-Energy House Layer House University of Tennessee, Knoxville Arc 572 I Spring 2008

BUILDING INTEGRATION OF RENEWABLE ENERGY SYSTEMS TOWARDS ZERO OR NEARLY ZERO ENERGY BUILDINGS

Analysis of Heat Gain in Computer Laboratory and Excellent Centre by using CLTD/CLF/SCL Method

A Strategic Study of Energy Efficient and Hybrid Energy System Options for a Multi-family Building in Korea

Solar Heating in Commercial Buildings

The REOSE Solar Panel Hause. Team ReGen

A STUDY ON DESIGN OPTIMIZATION OF A NEAR NET-ZERO ENERGY HOUSE

Homesol Passive House Design Process

Figure 1: Uncovered and covered PVT collectors

SIZING, POSITIONING AND AIR DUCTING ANALYSIS FOR SOLAR-BASED CAR VENTILATOR

Thermal Control in Buildings by John Straube (updated )

STEADY STATE AND DYNAMIC THERMOPHYSICAL PARAMETERS OF TRANSPARENT BUILDING COMPONENTS

DESIGN AND MODELING THE Φ-F

Adaption of the passive house concept in northern Sweden - a case study of performance

The Elithis Tower is an experimental and demonstration. Elithis Tower in Dijon, France. nzeb case studies

USE OF NET ZERO ENERGY SOLUTION SETS FOR THE REDESIGN OF THE REUNION ISLAND ENERPOS BUILDING IN CHRISTCHURCH

Performance of a Solar Heating System with Photovoltaic Thermal Hybrid Collectors and Heat Pump

OKO House by YOUMEHESHE architects

Jamie Shipley Senior Advisor Ontario Region Research and Information Transfer

Nearly Zero Energy Building in Lecco Modern technological building compared to an ancient Villa

Residential buildings retrofit: the role of solar technologies

Available online at ScienceDirect. Procedia Engineering 105 (2015 )

Assessing the energy performance of modern glass facade systems

171: An urban office designed for the southern Brazilian climate

Lecture 3: Utilization of Passive Solar Technology

THERMAL MASS IMPACT ON ENERGY PERFORMANCE OF A LOW, MEDIUM, AND HEAVY MASS BUILDING IN BELGRADE

Solar Cooling Technologies for Southern Climates - A System Comparison

Question # 1: Write true or false with correcting the wrong statement

What is Sustainable Design?

ASSESSMENT AND DESIGN OF ROOFTOP SOLAR PV SYSTEM. Click to begin

ScienceDirect ENERGY EFFICIENT REFURBISHMENT TOWARDS NEARLY ZERO ENERGY HOUSES, FOR THE MEDITERRANEAN REGION

Simulation Studies on Performance of Solar Cooling System in UAE Conditions

Transcription:

OPEN ACCESS www. wsforum.org Article Investigation of Photovoltaic Self-sufficiency for a Residential Building in Canada Mostafa Mehrtash 1, Stephané Hallé 1, Yvan Dutil 1, * and Daniel Rousse 1 1 Industrial research chair in technologies of energy and energy efficiency, École de Technologie Supérieure, 1100, rue Notre-Dame Ouest, Montréal (Qc) Canada, H3C 1K3 2 Full Affiliation / Address (M_address) E-Mails: mostafa@t3e.info; stephane.halle@etsmtl.ca; yvan@t3e.info; daniel@t3e.info; * Author to whom correspondence should be addressed; Tel.: +1-418-653-2910 Received: / Accepted: / Published: Abstract: In this study, the self sufficiency of a photovoltaic (PV) system installed on roof of a single story home is investigated for the particularly severe weather conditions of Canada. Since the local climate presents large daily and yearly temperature fluctuations, in addition to the presence of snow, drizzle and freezing rain, the design of renewable energy systems is very challenging. This research presents the investigation of both passive and active solar designs for a Canadian house. Self and transfer admittances of all surfaces were calculated. Furthermore, the zone admittance matrix has been derived for three different harmonics of weather inputs. The explicit finite difference model is used to calculate the temperature of the all nodes which are considered. Further, the equations resulted from the finite difference model are solved by MathCAD. The passive response of the house shows around 20 C difference between room-air and ambient average temperature in a winter day. The second part of this study includes the simulation of the PV system and house s energy consumption that was carried out by use of PVSOL. Consequently, by making a comparison between total consumption of the house and the electricity production by PV system, the self sufficiency of a PV system was evaluated. This system is theoretically self-sufficient since the designed PV system provides 70 kwh in a sunny winter day when the maximum required energy for the building is 30 kwh approximately. Keywords: solar energy; photovoltaic (PV); passive design; active design; self-sufficiency.

2 1. Introduction Nowadays, one of the most significant necessities in the world is energy. Due to limited fossil fuel resources, renewable energies have been become an appropriate solution. Solar energy has the largest potential among all renewable energy resources. The available solar energy available on Earth s surface is 36000 billion watts (3.6 10 4 TW ave ) when the wind energy resource base is 72TW ave, geothermal energy resource base is 9.7 TW ave, and the human energy use is 58TW ave [1]. Conversion of the solar irradiation on earth s surface with 100% efficiency, make possibility to provide energy for the world by using 1/1000 th of the earth s dry surface [2]. In recent years, solar energy has become an increasingly important source of renewable energy and it is expected to expand in the near future. Solar energy possess many advantages such as: no need for fossil fuels, has no moving parts to wear out, is not polluting in operation, is adaptable for on-site installation, is easy to maintain, and can be easily combined with other renewable energy sources. Photovoltaic (PV) technology plays a key role in producing electricity directly from the solar irradiation, with an efficiency of 10-20% approximately. Photovoltaic technology has advanced considerably in recent years. Several buildings that use only solar energy as their energy resource have been built and the two main technologies used were solar thermal collectors (STC) and PV. In Canada, buildings account for about 31% (17% residential) of Canada s energy consumption, for about 50% of its electricity consumption, and produce 28% of its greenhouse gases (GHG) emissions [3]. High energy consumption of buildings increases the interest in passive design [4]. Passive solar building is a qualitative term describing a building which utilizes solar gains to reduce heating and cooling loads based on natural energy flows. Unlike the active design, the passive design doesn t involve the use of mechanical or electrical devices. Passive design helps to provide a comfortable internal environment by using the local climatic conditions. The annual solar energy incident on the roof of a house far exceeds its total energy consumption. The first principle of passive solar design is absorbing and transmitting the maximum amount of radiation to the interior space of the building in winter time. Reduction of heat losses, shading controls, and utilization of natural ventilation are other passive solar design principles. However, if passive and active solar designs are used together, building efficiencies would be improved. In the active design part, designers use mechanical and electrical devices for heating, cooling and ventilating the building. PV systems, solar thermal collectors, and solar water heaters are main technologies to use solar energy in buildings. In this study, PV modules provide energy for an efficient residential building as the main source of energy for electric appliances. This paper is organized as follows. Section 1 has already introduced the passive and active solar designs. Section 2 explains the building physical characteristics and orientations. Section 3 describes the thermal analysis of the building. Section 4 presents our active solar design and its analyses. Finally, Section 5 demonstrates the self-sufficiency of a PV system for an efficient residential building in Canada. 2. Building Characteristics The analyzed building is a single story house with a basement and it is located in Montreal. This is a south facing house with a pitched roof. The aspect ratio (the ratio of length to width) of the building is 1.3, which is the optimal ratio to use solar radiation to heat the building. Walls are made up of gypsum board and insulation. The thermal mass (a concrete slab with 20 cm thickness) has been used in the floor to store the heat produced by solar radiation and also preventing overheating and decreasing the temperature fluctuations. Triple glazed windows with low emissivity coatings were utilized, since they have a high thermal resistance and solar heat gain coefficient. According to the literature, the yearly optimal angle to absorb the maximum amount of solar radiation by PV modules is equal to the local

3 latitude at low latitude locations, and up to 14 less than latitude at high latitudes [5]. In our case, a 45 slope pitched roof has been selected for installing PV modules, since the Montréal s latitude is 45.5. The main parameters of the house are shown in table 1. Table 1. Main physical parameters of the building Physical Parameter value Floor area, m 2 130 Total wall area, m 2 111.25 Internal height, m 3 South facing windows area, m 2 (10% of floor area) 14 Door area, m 2 3 Total west, north, and east facing windows area, m 2 9 Slope of the pitched roof, degrees 45 Roof area, m 2 2 91.91 The south facing windows have been selected with the optimum area (10% of floor area) to allow more solar radiation to enter the house in winter and to be stored in thermal mass. Two large area windows are used instead of many small area windows to minimize the heat loss through windows frames. The north facing windows have been used only to provide day lighting. This model has been studied for weather conditions of a typical winter day. 3. Thermal Analysis of the Building The input parameters for thermal analyses of building are: building dimensions, location of the building (latitude of 45 ), building orientation, thermal resistances, heat transfer coefficients, day number, ground reflectance, and basement temperature assumed 16 C. The calculations have been done by MathCAD. Thermal resistances of all components of the house were calculated and the results are shown in table 2. Table 2. R-value of house's components R-value of the windows, m 2 K/W 0.738 R-value of the door, m 2 K/W 1.2 R-value of the walls, m 2 K/W 3.482 R-value of the floor, m 2 K/W 1.388 Then, the thermal network of the house was plotted and used for calculation of nodes temperatures by using an explicit finite difference model. The energy balance equation is applied at each node and solved repeatedly at each time step for the period of simulation to find the temperature fluctuations. The outside temperature was modeled by a Fourier series. By using the admittance model, the admittances of all walls and windows were calculated and finally the total zone admittance matrix, shown as equation 1 analyzedfor the mean term and three different harmonics of the weather inputs were derived. Note that the first component of this matrix (Yz 0 ) is the total U-value of the house [6].

G(W/m 2 ) 4 (1) The incident solar radiation on each surface of the house was calculated. Direct, diffuse, and reflected radiations were considered. Hottel s clear sky model was employed to find the solar radiation on different surfaces of the house and also the ground reflected radiation. The correlation of Liu and Jordan was employed to find the diffuse component of radiation on different surfaces [7]. The hourly clearness index was employed for the assumed day (February 1 st ). The clearness index is the ratio of total horizontal solar radiation measured on the ground and the total horizontal solar radiation at the top of the atmosphere; it shows the cloudiness intensity of the sky [7]. After calculation of the incident solar radiation on exterior surfaces, transmitted solar radiation to the interior surfaces was calculated. It has been assumed that 70% of incoming solar radiation to the interior zone through windows is absorbed by the floor and the remainder by other surfaces in proportion to their areas. Figure 1 shows the transmitted solar radiation flux to the interior zone [8]. As it is shown, the main part of transmitted solar radiation comes from the south windows. The east windows transmit radiation only in the morning. In contrast, the west windows transmit radiation in the afternoon. The north windows transmit a negligible amount of radiation and only provide day lighting. Figure 1. Transmitted solar radiation flux by different surfaces 400 350 300 250 200 150 100 50 South Window West Window North Window East Window 0 0 5 10 15 20 25 Time(Hour) Furthermore, the passive response of the building (without using auxiliary heating) was found as it is shown in graph 2. The room air temperature fluctuation chart has almost the same shape as the ambient temperature but with lower amplitude. In the afternoon, diminution of both ambient temperature and solar irradiance led to lower room air temperature; however, the reduction rate of the room air temperature is considerably less (only 63%) than the external temperature.

Temprature (C) Figure 2. Passive response of the house 5 10 5 0-5 Room Air Temprature Ambient Temprature -10-15 -20 0 5 10 15 20 25 Time(Hour) 4. Active Solar Design The second element of design studied is active solar design. The simulation was carried out by PVSOL. As the first step, the consumption of a regular Canadian house was estimated. High efficiency electrical appliances were utilized to maximize energy savings. Mechanical and electrical devices are used for heating, cooling, and ventilating the inside environment of the house. The electrical appliances and their consumptions are listed in table 3. The total load is about 30 kwh/day. Table 3. Appliances used in proposed house appliance quantity power (W) Hours of use (h) Total load(wh/day) LED lights 12 10 4 480 Refrigerator & Freezer 1 800 8 6400 TV 1 150 3 450 Kitchen stove 1 1200 3 3600 CD player 1 20 1 20 Dish washer 1 1000 1 1000 Computer 1 200 4 800 Clothes washer & drier 1 2500 0.1 250 HVAC 1 1000 6 6000 Water pump Water heater 1 1 1000 1000 3 6 3000 6000 other appliances......... 2000 Total 30,000 Forty two Si Monocrystalline PV panels with efficiency of 16.2% and output power of 310 W from Canadian solar Inc. were utilized. Panels were installed on the roof tilted at 45. The output power of PV system is 13 kwp. There are many possible conditions to connect PV panels to each other. In this proposed design, the optimal condition has been selected according to the I-V characteristics of modules and inverters and to create more efficient system. The optimal configuration for the panels connections was selected: seven panels were connected in series and the two series connected in parallel. The same was done for the other two inverters. Furthermore, inverters best matched with the system were selected. Three 4.60 kw inverters were proposed for this system. Using a smaller number of inverters with high power is more efficient than using more inverters with low power. Simulation predicts 13.2% PV array efficiency, 94.5% inverter efficiency, and 12.5% overall efficiency of the system. The assumed day (February 1 st ) is completely clear. The PV array irradiation

6 and energy produced by PV array are shown in figure 3. The total PV array irradiation on a clear day is 510 kwh and the total electricity produced by PV array is 70 kwh. Figure 3. PV array irradiation and energy production Heat dissipated by the electric appliance will suffice to heat the house to a confortable temperature. If needed, the HVAC system can provide additional heating. 5. Conclusions Passive and active solar designs optimizations are performed in this study. Passive solar design principles were employed and the following analyses show that the average room air temperature of the designed building without using auxiliary heating is 4 C when the average of ambient temperature is -15 C on a winter day. High level insulation, using thermal mass, and applying the passive solar design principles allow this difference between ambient and room air temperature. The total consumption from electrical appliances in the house is a 30 kwh/day. A total of 42 PV modules installed on the house s roof provide the electricity. The total power of the designed PV system is 13 kwp. Results from simulation predict an electricity production of 70 kwh on February 1 st. Therefore, this production is enough to fulfill 30 kw.hr consumed by electrical appliances. Surplus could be stored in batteries or feed into the grid. Surpluses are large enough to insure that the house would have a net zero consumption over a year. However, autonomous operation is not granted as the energy storage needed for a long sequence of cloudy days in winter would be quite large. This raises this important question: Is this environmentally sound? The study demonstrates that Net Zero Energy operation could be achieved under Canadian winter conditions. However, a large amount of resources is used for the additional insulation and the fabrication of the solar panels and associated electrical system. Maybe, these would have been used better in the production of energy from other renewable sources (ex: wind, hydro), than trying to save the same amount of energy. Conflict of Interest Authors have no conflict of interest to declare. References and Notes

7 1. International Energy Outlook 2011, (IEA) 2. Ray, K. L. Photovoltaic Cell Efficiency at Elevated Temperatures, B. Sc. Thesis, Massachusetts Institute of Technology, USA, June 2010 3. Finch, G.; Burnnet, E.; Knowles, W. Energy Consumption in Mild and High Rise Residential Buildings in British Columbia, Proceedings from the 12 th Canadian Conference on Building Science and Technology, Montreal, Quebec, Canada, May 2009. 4. Rabah, K. Development of Energy-efficient Passive Solar Building Design in Nicosia Cyprus. Renewable Energy 2005, 30, 937-956. 5. Li, Z.; Liu, X.; Tang, R. Optical Performance of Vertical Single-axis Tracked Solar Panels. Renewable Energy 2011, 36, 64-68. 6. Athienitis, A. K. In Building Thermal Analysis, 2nd ed.; MathSoft Inc., Boston, USA, 1994. 7. Duffie, J. A.; Beckman, W. A. In Solar Engineering of Thermal Processes, 3rd ed.; John Wiley & Sons Inc., New Jersey, USA, 1994; pp. 60-89. 8. Helou, I. Thermal Model and Analysis of Two Zone Passive Solar House, Master of Applied Science Thesis, Concordia University, Montreal, Canada, September 2003. 2011 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/3.0/).