Expansion & Deflection Fittings. SOLUTIONS for the Construction Industry

Similar documents
Service Entrance Cable Fittings

DESIGN GUIDELINES WIRING AND CONDUITS PAGE 1 of 7

Electrical Metallic Tubing (EMT) Fittings

Electrical Metallic Tubing (EMT) Fittings

1-1/2 LB FM7 CND BD ELECTRO ZINC PLATED DICHROMATE EPOXY POWDER COATED

IRON CONDUIT BODIES 5-5/16 (135) 6-9/16 (167) 7-9/16 (192) 8-7/16 (214) 10-3/8 (264) 12-3/8 (314) 15-5/8 (397) 15-5/8 (397)

ALUMINUM OR MALLEABLE IRON CONDUIT BODIES

I-2 Unions, Sealing Fittings, Flexible Couplings, Elbows, Drain/Breather, Close-Up Plugs: Explosionproof UNILETS for Use with Threaded Metal Conduit

Cable Terminators COMMERCIAL AND INDUSTRIAL FITTINGS: RIGID AND IMC CONDUIT FITTINGS. Applications

Mogul Conduit Bodies, Covers and Gaskets For Rigid Conduit and IMC

Material/Finish Aluminum Copper-free aluminum (less than 4/10 of 1%) Electrostatically applied powder coating


Specifications Electrical Metallic Tubing (EMT)

Specifications Rigid Metal Conduit / PVC Coated Rigid Metal Conduit

ALUMINUM OR IRON CONDUIT BODIES

Red Dot. Rigid Fittings. Table of Contents

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

T&B Fittings. Industrial Fittings. Rigid Metal Conduit Fittings. Specifications Rigid Metal Conduit/PVC Coated Rigid Metal Conduit

1. Hangers and supports for electrical equipment and systems.

DMS CONDUIT EFFECTIVE DATE: APRIL

3. Intermediate metal conduit (IMC). 4. Electric metallic tubing (EMT). 5. Flexible metal conduit (FLEX). 6. Polyvinyl chloride conduit (PVC).

Design Standard Conduit for Electrical Systems

E-Z-Ground Grounding Systems. Ground Wire Size. Water Pipe Size. 1/2 in /4 in. 2 in /2 in. 3-1/2 in TB

Meter Connection Products: Overview

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION HVAC PIPES AND TUBES

Amphenol PT, SP, MS/PT Proprietary/MIL-C-26482, Series 1 solder type

Liquidtight Flexible Metal Conduit Fittings For Control and Power Cable Applications. * U.L. and CSA not applicable.

GLENWOOD PLACE 2 MAR 2015

ELECTRICAL CONTRACTORS THE UNIVERSITY OF TENNESSEE KNOXVILLE, TENNESSEE SECTION PAGE 1 SECTION SUPPORTING DEVICES

DIVISION 26 RACEWAYS AND BOXES FOR ELECTRICAL SYSTEMS PART 1 - GENERAL RELATED DOCUMENTS

1510 RACEWAY AND BOXES FOR ELECTRICAL SYSTEMS

A. Product Data: For surface pathways, wireways and fittings, floor boxes, hinged-cover enclosures, and cabinets.

SECTION (Master Template Final-05) ELECTRICAL BOXES. A. Provide boxes for electrical equipment and wiring devices as follows:

1. Hangers and supports for electrical equipment and systems. 2. Construction requirements for concrete bases.

SECTION GROUNDING AND BONDING

TUFF-SEAL RSF SERIES ALUMINUM CORD GRIPS. Toll Free Fax RSF Series Aluminum Flat Cable Cord Grips G 16

SECTION A. Underwriters Laboratories, Inc., listed and NEC approved

SECTION GROUNDING AND BONDING FOR ELECTRICAL SYSTEMS

SECTION RACEWAYS

NORTHWESTERN UNIVERSITY PROJECT NAME JOB #

Youngstown State University

REA LISTED. Throughout the catalog you will notice blue highlighted items. These are the most frequently ordered BURNDY Products.

SECTION RACEWAY AND BOXES FOR ELECTRICAL SYSTEMS

Section 2 Index PAGE 2-I. Metal Sheath and Ceramic Thermocouple Assemblies. AccuTru Sensor Technologies 2-1. Spring Loaded Hex Nipple w/ Head 2-2

SECTION VIBRATION AND SEISMIC CONTROLS FOR HVAC PIPING AND EQUIPMENT

EXBLT Series for Harsh and Hazardous Environments

W A R R A N T Y. CSA standard B51 certified. Inspected and tested by the Technical Standards and Safety Authority of Canada.

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

AMFICO AMERICAN FITTINGS. Use ONE Fitting on ALL Conduits. It s EMT, It s Rigid, It s IMC, It s UL Approved, It s Steel, It s American.

Multijacketed Tubing, Single-Jacketed Tubing, and Insulated Tubing

SECTION HANGERS AND SUPPORTS FOR PLUMBING

Standard Tube & Pipe Adapters

B. Provide a complete conduit system with associated couplings, connectors, and fittings.

Amphenol RF- SMA Connector Series

Features: Single-Gang Two-Gang Three-Gang Four-Gang Hubless Receptacles. Compliance: CSA Listed. B Index. February Master Index. Cat. No.

2. Fittings shall be threaded and finished similar to conduit. Threadless fittings shall not be used.

12/21/2018 WHAT S NEW SINCE What's New Since SPEC BOOK 2018 SPEC BOOK 2018 SPEC BOOK WHAT S NEW SINCE 2014

DIVISION 26 - ELECTRICAL Section Conduit for Electrical Systems 1. GENERAL 1.1 WORK INCLUDES

SECTION CHAIN LINK FENCING

SECTION ELECTRICAL SYSTEM RACEWAY and BOXES

Class 125S/200WOG Bronze Gate Valve Non-Rising Stem, Threaded Ends Testing: BS EN 12288, BS 5154, BS EN Working Pressure: PN16

This product specification is written according to the Construction Specifications Institute MasterFormat, 2014 Update.

SECTION VIBRATION CONTROLS FOR HVAC PIPING AND EQUIPMENT

SECTION B. Product Data: Provide manufacturer's standard details and installation instructions.

Duraflex and Megaflex can be tested under simulated operating conditions prior to shipment. Environmental Test Chamber. In-house X-Ray Capabilities

INDUSTRIAL TEMPERATURE SENSORS

CONDUITS AND FITTINGS

is Central. Gas Water & Waste Water Energy Industrial Your One-Stop Source State-of-the art manufacturing

Thermal Solutions Worldwide SECTION C. Industrial Thermocouples and RTDs. Straight Thermocouples Assemblies with Metal Protection Tubes C-5

Pipe. Valves. Fittings. Fasteners. Tube and Tube Fittings. And Much More

SECTION VIBRATION CONTROLS FOR PLUMBING PIPING AND EQUIPMENT

WIRING METHODS CHAPTER 38

SECTION CONDUITS AND BACKBOXES FOR COMMUNICATIONS SYSTEMS

STANDARD COAXIAL CONNECTORS

maximum mechanical protection

Raceway and Boxes for Electrical Systems Page 1 of 7

CHAPTER 11 CONDUITS AND FITTINGS

94110 Vacuum Vent. Features. Vacuum Vent. Less need for special materials in corrosive and extreme temperature

TUFF-SEAL RSSS SERIES STAINLESS STEEL CORD GRIPS. Toll Free Fax

SERVICES CHAPTER 35. wire. For all other installations, the rating of the ungrounded conductors shall be not less than 60 amperes.

AccuTru ExL High Temperature Thermocouples

TUFF-SEAL RSR SERIES ALUMINUM CORD GRIPS. Toll Free Fax RSR Series Straight Aluminum Cord Grips G 1

SMA SERIES COAXIAL CONNECTORS

SECTION GROUNDING AND BONDING FOR ELECTRONIC SAFETY AND SECURITY

PRODUCT CATALOG STAINLESS STEEL CONDUIT & FITTINGS ALL STAINLESS STEEL ALL IN STOCK

SECTION CONDUIT AND FITTINGS

SECTION PART 1 GENERAL

This product specification is written according to the Construction Specifications Institute MasterFormat, 2014 Update.

CONSTRUCTION SPECIFICATION FOR GROUNDING

BASIC ELECTRICAL MATERIALS AND METHODS

YF /8" YF /2" YF /4"

Flange Insulation Sets

CONDUIT ACCESSORIES AND FIXINGS

MGO INSULATED THERMOCOUPLES INDEX

Superior Backshell, Wire Protection and Accessories

Anaconda SEALTITE. When you say SEALTITE, there is only one: ANACONDA. Index FLEXIBLE CONDUIT TYPES 4-5. ANAMET Electrical, Inc.

1071 Cast Steel Globe Steam Stop Valve (Flanged)

t y p e V S A S E W A G E P U M P

SECTION BASIC FIRE SUPPRESSION MATERIALS AND METHODS. A. Section includes pipe, fittings, valves, and connections for sprinkler systems.

Extended-Frequency SMA Connectors

Transcription:

Expansion & Deflection Fittings SOLUTIONS for the Construction Industry

TTINGS FI ST D LO C AF/AF8 SERIES e st d, in M a c h e d, As d in D e s i g n e d, b le the Casted Body with NPT hub size se m Ca EXPANSION FITTINGS USA Galvanized Washer Tinned Copper Braid Type A Phenolic Insulating Bushing End Coupling Teflon Water Tight Packaging 2

AF/AF8 SERIES S T D LO C EXPANSION FITTINGS LISTED File E22699 AF8-75 AF-75 AF/AF8 Series Expansion Fittings are for use with IMC or rigid conduit installations. The AF/AF8 Series prevents damage of the electrical installations typically used in buildings and bridges by compensating linear movement due to temperature fluctuation or structural movement. This series provides up to a maximum 4 and 8 conduit movement (2 and 4 in either direction). For applications involving IMC, a 15 minimum length of rigid conduit should be used entering the expansion fitting due to the slightly smaller O.D. of the IMC. Conduit body is casted from a durable and natural corrosive resistant ZA12 zinc alloy Relies on tinned braided copper external bonding jumper (AJ Series Jumper) per NEC 250.98 Includes phenolic insulating bushing Contains PTFE synthetic fiber reinforced gasket with steel washer Tinned braided copper ring Rain, water and concretetight EXPANSION FITTINGS 4 CONDUIT MOVEMENT BONDING JUMPER HUB SIZE CATALOG # MAX. DIA. (A) LENGTH (B) CATALOG # 1/2 AF-50 2 6-1/4 AJ-5075-14 3/4 AF-75 2-1/4 6-3/8 AJ-5075-14 1 AF-100 2-5/8 6-5/8 AJ-100125-14 1-1/4 AF-125 3-1/8 6-5/8 AJ-100125-14 1-1/2 AF-150 3-1/2 6-5/8 AJ-150200-14 2 AF-200 4 7-1/8 AJ-150200-14 2-1/2 AF-250 4-1/2 7-1/2 AJ-250300-14 3 AF-300 5-3/8 8-1/8 AJ-250300-14 3-1/2 AF-350 6 8-1/2 AJ-350400-14 4 AF-400 6-5/8 8-5/8 AJ-350400-14 5 AF-500 8 9-1/2 AJ-500600-14 8 CONDUIT MOVEMENT BONDING JUMPER 1/2 AF8-50 2 10-1/4 AJ-5075-24 3/4 AF8-75 2-1/4 10-3/8 AJ-5075-24 1 AF8-100 5-5/8 10-5/8 AJ-100125-24 1-1/4 AF8-125 3-1/8 10-5/8 AJ-100125-24 1-1/2 AF8-150 3-1/2 10-5/8 AJ-150200-24 2 AF8-200 4 11-1/8 AJ-150200-24 2-1/2 AF8-250 4-1/2 11-1/2 AJ-250300-24 3 AF8-300 5-3/8 12-1/8 AJ-250300-24 3-1/2 AF8-350 6 12-1/4 AJ-350400-24 4 AF8-400 6-5/8 12-3/8 AJ-350400-24 5 AF8-500 8 11-1/8 AJ-500600-24 Add suffixes to the following for ordering logic: ZA12 (zinc Alloy) standard Hot Dipped Galvanized AF-50EG Aluminum AF-50AL Polyolefin Coated AF-50GG B A 3

D T S LO C DF SERIES DEFLECTION EXPANSION FITTINGS Conduit Designed, Casted, Machined, Assembled in the 316 Stainless Steel Screws USA Internal Tinned Copper Braid 316 Stainless Steel Bands Synthetic Silicone Molded Rubber Casted End Coupling 4

DF SERIES S T D LO C DEFLECTION EXPANSION FITTINGS LISTED File E22699 DF-100 DF Series Deflection Fittings compensate any directional movement between two conduit joints. These fittings can withstand sporadic vibrations channeled by rotating equipment or vehicular traffic. The DF Series allows for a ¾ contraction and extension movement as well as a 30 angular deflection to any direction and still maintain its structural integrity. Durable cast ZA12 (zinc alloy) end couplings for use with rigid or IMC conduit Stainless steel lap bands for superior corrosion resistance and to ensure fastened strength Silicone rubber sleeve for high UV and environmental corrosion resistance Tinned braided copper grounding straps for electrical continuity Rain, water and concretetight Add suffixes to the following for ordering logic: ZA12 (zinc Alloy) standard Hot Dipped Galvanized DF-50EG Aluminum DF-50AL Polyolefin Coated DF-50GG Angular Movement Axial Compression Axial Extension Lateral or Parallel Deflection DEFLECTION DF HUB SIZE CATALOG # MAX. DIA. (A) LENGTH (B) 1/2 DF-50 2-1/4 6-3/4 3/4 DF-75 2-1/2 6-3/4 1 DF-100 2-3/4 7 1-1/4 DF-125 3-1/8 7-1/4 1-1/2 DF-150 3-1/8 7-1/4 2 DF-200 3-7/8 8-1/8 2-1/2 DF-250 4-3/8 8-1/2 3 DF-300 5 8-1/2 3-1/2 DF-350 5-3/4 9-1/4 4 DF-400 6-1/4 9-1/4 5 DF-500 7-1/4 9-3/8 6 DF-600 8-1/4 9-3/8 B A 5

D T S LO C DF SERIES DEFLECTION EXPANSION FITTINGS LISTED File E22699 DF-75GG DF Series Coated Deflection Fittings compensate any directional movement between two conduit joints. The Polyolefin coat adds additional corrosion resistance in applications where abnormal environmental conditions exist. These fittings can withstand sporadic vibrations channeled by rotating equipment or vehicular traffic. DF fittings allow for a ¾ contraction and extension movement as well as a 30 angular deflection to any direction and still maintain its structural integrity. 40 mil Polyolefin exterior coating Durable cast ZA12 (zinc alloy) end couplings for use with rigid or IMC conduit Stainless steel lap bands for superior corrosion resistance and to ensure fastened strength Silicone rubber sleeve for high UV and environmental corrosion resistance Tinned braided copper grounding straps for electrical continuity Rain, water and concretetight Angular Movement Axial Compression Axial Extension Lateral or Parallel Deflection Conduit DEFLECTION DF HUB SIZE CATALOG # MAX. DIA. LENGTH 1/2 DF-50 2-1/4 6-3/4 3/4 DF-75 2-1/2 6-3/4 1 DF-100 2-3/4 7 1-1/4 DF-125 3-1/8 7-1/4 1-1/2 DF-150 3-1/8 7-1/4 2 DF-200 3-7/8 8-1/8 2-1/2 DF-250 4-3/8 8-1/2 3 DF-300 5 8-1/2 3-1/2 DF-350 5-3/4 9-1/4 4 DF-400 6-1/4 9-1/4 5 DF-500 7-1/4 9-3/8 6 DF-600 8-1/4 9-3/8 316 Stainless Steel Screws Internal Tinned Copper Braid Specifications Contains no VOCs and no halogens Sealing boots for conduits Field Repairable Add suffixes to the following for ordering logic: ZA12 (zinc Alloy) standard Hot Dipped Galvanized DF-50EG Aluminum DF-50AL Polyolefin Coated DF-50GG A 316 Stainless Steel Bands B Synthetic Silicone Molded Rubber Casted End Coupling 6

AF/AF8 SERIES S T D LO C EXPANSION FITTINGS LISTED File E22699 AF-75GG AF/AF8 Series Coated Expansion Fittings are for use with IMC or rigid conduit installations. The polyolefin coat adds additional corrosion resistance in applications where abnormal environmental conditions exist. This series still prevents damage of the electrical installations typically used in buildings and bridges by compensating linear movement due to temperature fluctuation or structural movement. This series provides up to a maximum 4 and 8 conduit movement (2 and 4 in either direction). For applications involving IMC, a 15 minimum length of rigid conduit should be used entering the expansion fitting due to the slightly smaller O.D. of the IMC. B A 40 mil polyolefin exterior coating Conduit body is cast from durable and naturally corrosive resistant ZA12 alloy Relies on tinned braided copper external bonding jumper (AJ Series) per NEC 250.98 Includes phenolic insulating bushing Contains PTFE synthetic fiber reinforced gasket with steel washer to help maintain a strong seal Tinned braided copper ring Rain, water and concretetight Specifications Contains no VOCs and no halogens Sealing boots for conduits Field Repairable Add suffixes to the following for ordering logic: ZA12 (zinc Alloy) standard Hot Dipped Galvanized AF-50EG Aluminum AF-50AL Polyolefin Coated AF-50GG EXPANSION FITTINGS 4 CONDUIT MOVEMENT BONDING JUMPER HUB SIZE CATALOG # MAX. DIA. (A) LENGTH (B) CATALOG # 1/2 AF-50GG 2 6-1/4 AJ-5075-14 3/4 AF-75GG 2-1/4 6-3/8 AJ-5075-14 1 AF-100GG 2-5/8 6-5/8 AJ-100125-14 1-1/4 AF-125GG 3-1/8 6-5/8 AJ-100125-14 1-1/2 AF-150GG 3-1/2 6-5/8 AJ-150200-14 2 AF-200GG 4 7-1/8 AJ-150200-14 2-1/2 AF-250GG 4-1/2 7-1/2 AJ-250300-14 3 AF-300GG 5-3/8 8-1/8 AJ-250300-14 3-1/2 AF-350GG 6 8-1/2 AJ-350400-14 4 AF-400GG 6-5/8 8-5/8 AJ-350400-14 5 AF-500GG 8 9-1/2 AJ-500600-14 8 CONDUIT MOVEMENT BONDING JUMPER 1/2 AF8-50GG 2 10-1/4 AJ-5075-24 3/4 AF8-75GG 2-1/4 10-3/8 AJ-5075-24 1 AF8-100GG 5-5/8 10-5/8 AJ-100125-24 1-1/4 AF8-125GG 3-1/8 10-5/8 AJ-100125-24 1-1/2 AF8-150GG 3-1/2 10-5/8 AJ-150200-24 2 AF8-200GG 4 11-1/8 AJ-150200-24 2-1/2 AF8-250GG 4-1/2 11-1/2 AJ-250300-24 3 AF8-300GG 5-3/8 12-1/8 AJ-250300-24 3-1/2 AF8-350GG 6 12-1/4 AJ-350400-24 4 AF8-400GG 6-5/8 12-3/8 AJ-350400-24 5 AF8-500GG 8 11-1/8 AJ-500600-24 7

D T S LO C TAF SERIES EXPANSION FITTINGS LISTED File E22699 TAF-75 TAF Series Expansion Fittings compensate for linear movement between two conduit joints in runs of EMT (electrical magnetic tubing) conduit. This series provides up to a maximum 4 conduit movement (2 in either direction). Aids in preventing damaged conduit runs caused by temperature fluctuations and structural variations by assisting in movement. TAF Series conduit body, cast from durable and naturally corrosive resistant ZA12 alloy, contains the following:»» Phenolic insulating bushing»» PTFE synthetic fiber reinforced gasket with steel washer»» Tinned braided copper ring Includes 8 steel conduit nipple Two steel EMT conduit connectors Relies on tinned braided copper external bonding jumper (AJ Series) Concretetight TAF SERIES EMT EXPANSION FITTINGS HUB SIZE CATALOG # BONDING JUMPER CAT. # 1/2 TAF-50 AJ-5075-24 3/4 TAF-75 AJ-5075-24 1 TAF-100 AJ-100125-24 1-1/4 TAF-125 AJ-100125-24 1-1/2 TAF-150 AJ-150200-24 2 TAF-200 AJ-150200-24 2-1/2 TAF-250 AJ-250300-24 3 TAF-300 AJ-250300-24 3-1/2 TAF-350 AJ-350400-24 4 TAF-400 AJ-350400-24 Add suffixes to the following for ordering logic: ZA12 (zinc Alloy) standard Aluminum TAF-50AL 8

AJ/AJE SERIES S T D LO C BONDING JUMPERS LISTED File E22699 & E44925 AJ Type AJ Type Type AJ is used for bonding two rigid, EMT or IMC steel/aluminum conduits together to ensure the required electrical conductivity between raceways. Type AJE is used for bonding conduit to flat surfaces, such as boxes to ensure the required electrical conductivity between raceways. Clamps and U-Bolts are electro-galvanized Sizes Braid lengths listed are measured fully extended AJ SERIES BONDING JUMPERS 14 CATALOG # TRADE SIZE (IN) AJ-5075-14 1/2 and 3/4 AJ-100125-14 1 and 1-1/4 AJ-150200-14 1-1/2 and 2 AJ-250300-14 2-1/2 and 3 AJ-350400-14 3-1/2 and 4 AJ-500600-14 5 and 6 AJE SERIES BONDING JUMPERS 16 CATALOG # TRADE SIZE (IN) AJE-5075-16 1/2 and 3/4 AJE-100125-16 1 and 1-1/4 AJE-150200-16 1-1/2 and 2 AJE-250300-16 2-1/2 and 3 AJE-350400-16 3-1/2 and 4 AJE-500600-16 5 and 6 AJ SERIES BONDING JUMPERS 24 CATALOG # TRADE SIZE (IN) AJ-5075-24 1/2 and 3/4 AJ-100125-24 1 and 1-1/4 AJ-150200-24 1-1/2 and 2 AJ-250300-24 2-1/2 and 3 AJ-350400-24 3-1/2 and 4 AJ-500600-24 5 and 6 AJE SERIES BONDING JUMPERS 24 CATALOG # TRADE SIZE (IN) AJE-5075-24 1/2 and 3/4 AJE-100125-24 1 and 1-1/4 AJE-150200-24 1-1/2 and 2 AJE-250300-24 2-1/2 and 3 AJE-350400-24 3-1/2 and 4 AJE-500600-24 5 and 6 9

D T S LO C AFDF COMBO SERIES EXPANSION COMBO FITTING LISTED File E22699 AFDF-75 AFDF Series Expansion/Deflection Combo Fittings compensates for linear and 3/4 level movement in any direction between two conduit joints in runs of IMC or rigid conduit. AFDF Series combines the DF style fitting with the AF style fitting for an additional 4 movement (2 in either direction) when the 3/4 linear movement in the DF is not enough. Helps prevent damaged conduit runs caused by temperature fluctuations and structural variations by assisting in movement. AF Series Conduit body is casted from durable and naturally corrosive resistant ZA12 zinc alloy Includes tinned braided copper external bonding jumper (AJE Series) Includes phenolic insulating bushing PTFE Teflon reinforced gasket with steel washer Fittings are assembled with malleable, ductile iron or steel nipple Rain, water and concretetight DF Series Durable casted ZA12 zinc alloy end couplings with standard tapered threads for rigid or IMC conduit Stainless steel lap bands for superior corrosion resistance and to ensure fastened strength Silicone Rubber sleeve for high UV and environmental corrosion resistance Tinned braided copper grounding straps for electrical continuity Rain, water and concretetight AFDF COMBINATION DEFLECTION/EXPANSION HUB SIZE CATALOG # MAX. DIA. (A) EST. LENGTH (B) 1/2 AFDF-50 2-1/4 15 3/4 AFDF-75 2-1/2 15-1/8 1 AFDF-100 2-3/4 15-5/8 1-1/4 AFDF-125 3-1/8 15-7/8 1-1/2 AFDF-150 3-1/2 15-7/8 2 AFDF-200 4 17-1/4 2-1/2 AFDF-250 4-1/2 18 3 AFDF-300 5-1/8 18-5/8 3-1/2 AFDF-350 6 19-3/4 4 AFDF-400 6-5/8 20 5 AFDF-500 8 21 Add suffixes to the following for ordering logic: ZA12 (zinc alloy) standard Hot Dipped Galvanized AFDF-50EG Aluminum AFDF-50AL Polyolefin Coated AFDF-50GG B A 10

KILLARK FITTINGS FITTINGS FITTINGS UNF/UNY SERIES H A Z H A Z LO C LO C EXPANSION CONDUIT UNIONS UNFS Type Female/Female UNFL Type Female/Female Class I, Div. 1 & 2, Groups C,D Class I, Zone 1, Groups IIB, IIA Class II, Div. 1 & 2, Groups E,F,G Class III UL Standards 886 and 1203 CSA Standard C22.2 No. 30 Mil Spec: MIL-F28675 UNYS Type Male/Female UNYL Type Male/Female File No. E 10514 Certified File No. LR11716 UNFS & UNYS Standard Length UNFL & UNYL Long Length Application To provide for slight expansion and contraction of conduit runs To retrofit sections of conduit runs Tapered threaded hubs (NPT) for rigid conduit and IMC Telescoping components allows conduit to be inserted between fixed threaded hubs Internal zinc plated carbon steel spring with dichromate dip assures positive grounding Close tolerance of mating parts eliminates passage of flame Compact diameter allows use where conduit is closely spaced Available in standard and long style, male and female version Body/Sleeve Steel/Zinc Electroplate Grounding Spring Zinc plated carbon steel spring/natural Finish FEMALE SHORT DIMENSIONS CATALOG HUB SIZE NUMBER MAXIMUM MAXIMUM MALE THREAD DIAMETER C LENGTH A LENGTH B LENGTH D UNFS1 1/2 3.34 (85) 2.84 (72) 1.19 (30) - UNFS2 3/4 3.53 (90) 2.97 (75) 1.44 (37) - UNFS3 1 3.69 (94) 3.08 (78) 1.69 (43) - FEMALE LONG DIMENSIONS CATALOG HUB SIZE NUMBER MAXIMUM MAXIMUM MALE THREAD DIAMETER C LENGTH A LENGTH B LENGTH D UNFL1 1/2 4.34 (110) 3.34 (85) 1.19 (30) - UNFL2 3/4 4.53 (115) 3.47 (88) 1.44 (37) - UNFL3 1 4.69 (119) 3.58 (91) 1.69 (43) - MALE SHORT DIMENSIONS CATALOG HUB SIZE NUMBER MAXIMUM MAXIMUM MALE THREAD DIAMETER C LENGTH A LENGTH B LENGTH D UNYS1 1/2 3.48 (88) 2.97 (75) 1.19 (30).875 (22) UNYS2 3/4 3.60 (91) 3.03 (77) 1.44 (37).875 (22) UNYS3 1 3.93 (100) 3.15 (80) 1.69 (43) 1.100 (28) MALE LONG DIMENSIONS CATALOG HUB SIZE NUMBER MAXIMUM MAXIMUM MALE THREAD DIAMETER C LENGTH A LENGTH B LENGTH D UNYL1 1/2 4.48 (114) 3.48 (88) 1.19 (30).875 (22) UNYL2 3/4 4.60 (117) 3.53 (90) 1.44 (37).875 (22) UNYL3 1 4.75 (121) 3.65 (93) 1.69 (43) 1.100 (28) Dimensions UNFS UNFL UNYS UNYL 11

Other Fittings from Killark ALUMINUM CABLE CONNECTORS Designed for use with jacketed interlocked, continuously corrugated and welded armor cable. Install where it is essential to provide positive grounding to the cable and for a Type 3,4 connection. MC 360 armor grounding spring is reuseable. Robust threads and world class seal enables easy installation with minimal torque required. Design meets and exceeds third party requirements for cable retention. Provides sealing back nut plus inner o-ring seal to prevent moisture ingress to the cable armor and enclosure. Copper free aluminum construction for hostile, corrosive and certain hazardous locations Entry thread sizes 1/2 through 4 ALUMINUM OR MALLEABLE IRON CONDUIT BODIES C Type To provide access to conductors for pulling, splicing, and maintenance. Threaded for rigid conduit and IMC. Tapered threaded hubs (NPT) Raintight when used with gasketed covers Interchangeable with competitive products Stainless steel screws on stamped and cast covers Available in both copper free aluminum and malleable iron 9 hub configurations E Type HKSB-AFAF8 04-18 Killark, 2018 Hubbell Killark 3940 Dr. Martin Luther King Drive St. Louis, MO 63113 Phone: (314) 531-0460 Fax: (314) 531-7164 www.hubbell-killark.com