*Nominal values are to be used as guidelines only; this is not a product specification and does not indicate minimum or maximum values.

Similar documents
HDPE Conduit Specification 2011

HDPE Innerduct and Conduit. Power and Telecom.

Composite Production Systems Global Poly Linepipe

FUSIBLE PVC PIPE SYSTEMS Fusible C-900 Fusible C-905 FPVC

Experience and a History in Construction Products

SPECIFICATION FOR DUCT, HDPE Main Mini & Micro-Ducts

Ducts and Microducts HDPE PIPES FOR FIBER OPTIC & CABLE PROTECTION

Summary of Substantive Changes between the 2015a and 2017 editions of ASTM F876 Crosslinked Polyethylene (PEX) Tubing

CATALOG INNERDUCT & CUSTOM ARMOR PRODUCT CATALOG. CPID Protect-N-Duct Innerduct Single Kortech HDPE Solid Wall Accessories A PART OF

GUIDE TO SPECIFYING HDPE CONDUIT TN-50

TECHNICAL BULLETIN SPECIFICATIONS FOR MICRODUCT AND FUTUREPATH

SECTION GS10300 UNDERGROUND TRENCHING AND EXCAVATION CONSIDERATIONS

For domestic water and chilled water applications Texas A&M University requires minimum of SDR11 and meeting the following minimum specifications:

TECHNICAL SPECIFICATION FOR OPTICAL FIBER CABLE

TECHNICAL SPECIFICATION FOR OPTICAL FIBER CABLE

GUIDE TO SPECIFYING HDPE CONDUIT TN-50

SECTION HIGH DENSITY POLYETHYLENE PIPE AND FITTINGS

APPENDIX C TECHNICAL SPECIFICATIONS HIGH DENSITY POLYETHYLENE (HDPE) PIPE AND FITTINGS

DRISCOPLEX 6500 MDPE PIPE and FITTINGS DATA SHEET


OHIO UNIVERSAL MARKING STANDARDS APWA COLORS or

U.S. Department of Transportation Pipeline and Hazardous Materials Safety Administration Plastic Pipe

Model Specifications for Sclairpipe High Density Polyethylene (HDPE) Pipe

Ohio Utilities Protection Service Safety Presentation

MERIFLEX PE PRESSURE PIPES DATA SHEET

MUNICIPEX WATER SERVICE LINE TESTED. TRUSTED. CHOSEN BY PROFESSIONALS. Automotive Industry

PTFE Thread Sealant Tape Special Service Colors

Why Use PolyPipe? Quality Assurance in Product Design and Materials

15 kv EPR Insulated, Jacketed, URD Cable

Screen & 3-Season Porches

SPECIFICATION for ISCO HDPE DUAL CONTAINMENT PIPE

Plastic Pipe and Fittings Association ASTM D2239, D3035, D2737

PO Box 1081 Monticello, MN Ph Fax

SPECIAL SPECIFICATION 6623 Multi-Duct Conduit System

TWD (Flat / Multi Duct)

SECTION 200 SANITARY SEWER MATERIAL SPECIFICATIONS

The Miss Utility process begins when a locate request is received by the Virginia Utility Protection Service, more commonly known as Miss Utility.

Uniform Color Code and Marking Guidelines

ENGINEERED SOLUTIONS INNERFLOW INSTALLATION GUIDE

Specifications for SWC #110: Pipe, Pipe Liner, & Liner Installation

CIPP REFERENCE SPECIFICATION

PIPE REHABILITATION. Comply with Division 1 - General Provisions and Covenants, as well as the following:

Tubing & Fittings. Section H

SAPPCO DAMMAM FACTORY

DRISCOPLEX 6500 Series

Sclairpipe VERSATILE HIGH DENSITY POLYETHYLENE PIPE

*** Supercedes: BECO E and COM , , & ***

GENERAL SPECIFICATION FOR THE REHABILITATION OF SEWERS USING THE THERMOFORM (PVC) PIPE LINING SYSTEM

Kaf-Tech Product Specification

Shinn Thon UK Ltd 1 st Floor, 223 Dalton Road, Barrow in Furness, Cumbria. LA14 1PQ Tel: Fax:

Article number: Sheath marking ACE - TKF LTC-S RP 24x SM G.657.A1 6x4 A-DQ(ZN)B2Y {Batch} {Year} {Length}

IDENTIFICATION DEPOT, INC. 101 Fairway Drive Washington, NC PHONE FAX

Contents. dimensions and weights external loads deflection and testing installation...17

This product specification is written according to the Construction Specifications Institute MasterFormat, 2014 Update.

O Coaxial/Fiber/Microduct Hybrid Buried Cable. Serves businesses in a new commercial serving area. Mitigates future cost of fiber installation

Installation Guide BLUE904 PEX MUNICIPAL WATER SERVICE TUBING. We Build Tough Products for Tough Environments

WESTERN UNDERGROUND COMMITTEE GUIDE 2.14 (2.14/01/0990)

MaxCell Technical Manual. Design Parameters 4G Product Line

SECTION 8 SEPARATION OF LINES

This product specification is written according to the Construction Specifications Institute MasterFormat, 2014 Update.

PE Pressure Pipe POLYETHYLENE TO 1000MM DIAMETER

PE100 Pipes. Applications. Presented By: Khaled Al-Bani Technical Marketing HDPE Polymers SBU

Parflex/Atlantic. Fluoropolymer Tubing Products. Catalog 4150/USA March 2003 revised Sept. 2003

ELECTRICAL & TELECOMMUNICATIONS DUCTING & CONDUIT PVC & POLYETHYLENE SYSTEMS

HDPE HDPE. Factory PRESSURE PIPING SYSTEM DRAINAGE & SEWERAGE PIPING CABLE DUCT & SUB DUCT. Since 2002 HDPE. for Sewerage Storm Water System HDPE

SECTION HIGH DENSITY POLYETHYLENE PIPE AND FITTINGS (PRESSURE PIPE)

EVALUATION SUBJECT: VIEGA LLC S PUREFLOW PLUMBING SYSTEM

GUIDANCE MEMO NO : GUIDANCE CRITERIA FOR THE SEPARATION OF WATER MAINS AND NON-POTABLE PIPELINES

HDPE HDPE. Factory PRESSURE PIPING SYSTEM DRAINAGE & SEWERAGE PIPING CABLE DUCT & SUB DUCT. Since 2002 HDPE. for Sewerage Storm Water System HDPE

Standard Specification for Poly(Vinyl Chloride) (PVC) Pressure-Rated Pipe (SDR Series) 1

LANE ENTERPRISES, INC. STANDARDS & SPECIFICATIONS

COD. (Corrugated Optic Duct)

TECHNICAL SHEET. Printline Versaprofiles GEOPERFORMX V2 pipe is identified with permanent marking and sequential footage numbering every two (2) feet.

TECHNO GROUP TECHNO PLAST. TECHNO PLAST : Pipe Extrusion manufacturer. TECHNO FIT : Injection moulding manufacturer

DRISCOPLEX 5300 SERIES CLIMATE GUARD SYSTEMS

SUB WATER DEPARTMENT STANDARD CONSTRUCTION SPECIFICATIONS TABLE OF CONTENTS SECTION POLYETHYLENE PRESSURE PIPE

PERFORMANCE PIPE DRISCOPLEX 4000/4100 Pipe Water and Wastewater Piping Systems

Independent certification of your products & services. 2.2 Relevant Standards 1. SCOPE

TOTAL CAPABILITIES IN THE PIPELINE INDUSTRY. UTILITY TECHNOLOGIES INTERNATIONAL CORPORATION Cincinnati Columbus West Jefferson

C900/RJ. CertainTeed. PVC Pipe. with CertainTeed s proven Certa-Lok restrained joint system. Directional Drilling

10.0 Storm Sewer Systems

Multijacketed Tubing, Single-Jacketed Tubing, and Insulated Tubing

PATHWAYS MAKE IT POSSIBLE MDU MULTIPLE DWELLING UNIT

SECTION HORIZONTAL DIRECTIONAL DRILLING

SINGLE-WALL DRAINAGE PIPE (SWP) TECHNICAL DATA

CEDAR RAPIDS METROPOLITAN AREA STANDARD SPECIFICATIONS FOR PUBLIC IMPROVEMENTS May 2014 SECTION SEWER LINERS

SRPE AASHTO Specifications.

DRAINAGE PIPE PRODUCT CATALOGUE

Arctic Insulation & Manufacturing The Pre-Insulated Pipe People

Shrink-Kon Thin Wall Heat Shrinkable Tubing

Vikimatic MultiCell Conduit Systems

PVC. System Specifications TABLE 1 TABLE 2

Increasing Importance of Rapid Crack Propagation (RCP) for Gas Piping Applications - Industry Status

DUCTILE IRON PIPE AND FITTINGS

Special Specification 6016 Intelligent Transportation System (ITS) Multi-Duct Conduit

Wiring Ducts. Features. Applications. Ordering Information

C900/RJ. CertainTeed. PVC Pipe. with CertainTeed s proven Certa-Lok restrained joint system. Directional Drilling

SECTION 7 SEPARATION OF WATER MAINS AND SANITARY SEWERS

Telephone Duct Type B

PLASTIC FITTINGS Avenue Edmonton, AB Canada T6E 5Z7. Toll Free: Phone: (780) Fax: (780)

Transcription:

UNITED POLY SYSTEMS C O N D U I T Applications include: Installation: T e l e c o m, E n e r g y, D O T, E t c. E x i s t i n g C o n d u i t, P l o w, D i r e c t B u r i a l, H D D ( H o r i z o n t a l D i r e c t i o n a l D r i l l i n g ) Property Range or Minimum Requirement Units Cell Class Test Method Density 0.941-0.955 g/cc 3 ASTM D 792 or 1505 Melt Index a <0.25-0.40 g/10 minutes 3or4 ASTM D 1238 Flexural Modulus 110,000-160,000 Psi 4or5 ASTM D 790 Tensile Strength 3000-4000 Psi 4or5 ASTM D 638 Environmental Stress Crack Resistance b F20>192 Hours (condition C) 3or4 ASTM D 1693 HDB Not Defined 0,1,2,3,or 4 ASTM D2837 *Nominal values are to be used as guidelines only; this is not a product specification and does not indicate minimum or maximum values.

Print line The duct product shall be sequentially marked and identified along its outer length in contrasting color. The print interval shall be every two feet and shall include the following: MANUFACTURER'S NAME: United Poly Systems PRODUCT SIZE/SDR PRODUCTION CODE (Date, Location, Period) SPECIFICATION LENGTH OF CONDUIT (in feet) on reel Optional custom print lines are available and may include customer name, project name, application etc. Minimum Order Quantities Minimum order quantities are as follows: Size (in) Color Minimum (ft) ¾ Any 2500 1 Any 2500 1 ¼ Orange or Black 2000 1 ¼ Other 3000 1 ½ Orange or Black 1500 1 ½ Other 2500 2 Orange or Black 1000 2 Other 2000 2 ½ Orange or Black 2500 2 ½ Other 5000 3 Orange or Black 1000 3 Other 2000 4 Orange or Black 500 4 Other 750 Ducts larger than 4 diameter offered in black or w/stripes only 5 1000 6 900 8 560 10 560 12 480 14 560 16 480

Reel Dimensions Standard dimensions for United Poly Systems reels are as follows: All reels come in a standard 48 width unless otherwise requested by customer. Standard common reel diameters are 48, 66, 72, 83 96, 102, 114 and 120. Segmented reels are also available in 2-way, 3-way or 4-way configurations. United Poly Systems does not currently parallel wrap duct. ¾ and 1 size ducts are wrapped to a preferred diameter reel size of 48, 66 or 72. 6 duct is offered on 450 120 reels or in coils of 500 United Poly Systems will not coil 4 schedule 40 HDPE pipe due to the potential for compromise of product integrity. Options Straight longitudinal internal ribbing is available for all pipes 2 and below. o UNIFORM STRAIGHT INTERNAL RIBS SPANNING THE LENGTH OF THE PIPE Optional custom print lines are available and may include customer name, project name, application, lightning bolt etc. Pull tape is offered in a number of tensile strengths. United Poly Systems standard pull tape is an 1130# strength, while other options include strengths from 200# to 2500#. Segmented reels are available in 2-way, 3-way or 4-way configurations. United Poly Systems does not currently parallel wrap duct. A number of colors and stripes are offered to customize the product to the customer s needs. United Poly Systems offers orange, blue, black, red, gray, white, green, yellow, terracotta, violet, brown, lilac, and custom colors upon customer s request. Custom colors available upon request

Coil Sizes Standard coil lengths are as follows: Size (in) Standard Coil Footages (ft) Quantity per pallet Coil ID(in) Coil Width (in) ¾ 500 1000 8 30 10 20 1 500 1000 7 5 30 11 20 1 ¼ 500 1000 5 3 30 16 29.5 1 ½ 500 1000 8 6 51-51 13.5 16 2 500 1000 1500 2000 7 4 3 3 51 51 51-51 14 22.5 28 32 3 500-1000 4 2 69.5 69.5 23.5 45 4 500 600 800 3 2 2 2 69.5 70 69.5 31 48 49 5 500 2 84 50 6 450 2 84 50 Internal Ribbing United Poly Systems is proud to offer HDPE duct with longitudinal internal ribbing for ¾ to 2 diameters. Ribbed duct offers a way to maximize the distance cable may be pulled and jetted into conduit. The internal ribs help to reduce the coefficient of friction within that particular pipe. Air may flow more readily around the cable and contact with the wall of the duct is reduced thereby reducing friction and simplifying instillation. Inside ribbed duct is available up to 6 diameter conduit. Ribbed conduit is offered on segmented reels with or without any of our pre-installed pull tape options and can be manufactured in any solid color or striping. Custom colors available upon request

Notes Ovality of 2 inch and smaller conduit shall not exceed 7% off the coil. Coiled conduit larger than 2 inch through 3 inch IPS shall not exceed 10%. Ovality in coiled 4 inch and greater diameter conduit and casing is largely a packaging condition where greater than 15% ovality shall be corrected in the field by processing the roundable conduit through re-rounding and straightening equipment during installation. Straight lengths of conduit shall have ovality of 5% or less. PPI. HDPE Solid Wall Conduit Model Specification Power and Communications Conduit and Casing. Tech. no. MS-5. 2008. HDPE conduit will ovalize when it is coiled, and after a period of time,will set into the coiled state. A residual curve is normal for all coiled HDPE duct products. Since larger duct is coiled into a relatively tighter bending radius, residual curvature and ovality is greater for larger diameters. Some couplers may be affected by ovalized duct, along with installations where cable-fill ratios reach near capacity, or where larger diameter cables are being placed. Residual curvature and ovality may be corrected in the field by running the entire coil through rerounding and straightening equipment during installation. Schedule 40 HDPE conduit through 3 has a wall thickness greater than SDR 15.5. Schedule 40 HDPE conduits in diameters above 3 and Schedule 80 in 6 have wall thickness ranges that are less than SDR 15.5. United Poly Systems will not offer these sizes in continuous coils to preserve pipe integrity and limit ovality. All HDPE pipes produced under ASTM D3035, F714, D2447, D2239 and D2737 specifications are suitable for the transport of liquids, including water, fluid chemicals, effluents, municipal sewage, etc. The user should consult with the HDPE pipe manufacturer to determine whether the composition of the liquid material being transported is compatible with polyethylene pipe so as not to affect the service life below limits acceptable to the user. PPI. Resistance of Solid Wall Polyethylene Pipe to a Sanitary Sewage Environment. Tech. no. 15. 2009.

Pressure Rating (psig) Comparison Between PE 4710 and PE 3408 for Water Applications DR 9 DR 11 DR 13.5 DR 17 PE 4710 252 202 161 126 PE 3408 200 160 128 100 RECOMMENDED COLOR CODE This color code is only intended for solid wall pipe used outside of buildings Color or Stripe Color Red Orange Solid Wall Piping Application Electric power lines, cable, conduit, and lighting cables Telecommunication, alarm or signal lines, cables, or conduit The recommended color code provided in this document is consistent with the American Public Works Association (APWA) Uniform Color Code. Yellow Green Blue Violet(Purple) Fuel gas (methane or propane), oil, petroleum, steam, or gaseous materials Sewers and drain lines Potable water Reclaimed water, irrigation, and slurry lines