The Effects of Tempered Glass with Low Iron Oxide (Fe 2 O 3 ) Content on the Efficiency of Solar Air Heater

Similar documents
An Experimental Investigation of the Energy and Exergy Efficiency of Extended Surface Solar Air Heaters

Exergy analysis of a flat plate solar collector

Solar Flat Plate Thermal Collector

Experimental Studies on a Solar Assisted Heat Pump Working with R22: An Exergy Point of View

Feasibility study of a roof top Solar room heater

Experimental investigation of single-phase and twophase closed thermosyphon solar water heater systems

SOLAR DESALINATION AUGMENTED WITH EVACUATED-TUBE COLLECTOR

International Journal of Mechanical & Mechatronics Engineering IJMME-IJENS Vol:16 No:05 14

EXPERIMENTAL INVESTIGATION OF SOLAR AIR COLLECTOR BY COMPARING GLASS WOOL AND FOAM AS AN INSULATION MATERIAL

Thermal Analysis of Solar Flat Plate Collector

Chapter 7. Passive Solar Contents

Calculation and Fabrication of a Solar Flat Plate Collector Efficiency using Mild Steel as Absorber Plate

Thermodynamics Analysis of a Forced Convection Solar Air Heater Using Artificial Neural Network

Advances in Engineering Research, volume 103 Proceedings of the 3rd International Conference on Material Engineering and Application (ICMEA 2016)

Experimental Investigation of SAHs Solar Dryers with Zigzag Aluminum Cans

2. Inclined solar panel basin solar still in passive and active. mode

Collector Efficiency of the Double-Pass Solar Air Collectors with Fins

International Journal of Engineering Research & Science (IJOER) ISSN: [ ] [Vol-2, Issue-6, June- 2016]

Evaluation of efficiency and collector time constant of a solar flat plate collector

International Journal of Mechanical Civil and Control Engineering. Vol. 1, Issue. 3, June 2015 ISSN (Online):

An Experimental Study on Evacuated Tube Solar Collector for Heating of Air in India Avadhesh Yadav, V.K. Bajpai

Observation of Liquid-filled Window without Presence of Liquid in Test Chamber

ENHANCEMENT OF GRANITE STONE FLAT PLATE COLLECTOR EFFICIENCY USING MULTIPLE COVERS

Design Considerations for Flat Plate Solar Water Heater System

Performance Testing of A Parabolic Trough Collector Array

Effect of Distance between Double Glazing on the Performance of a Solar Thermal Collector Control

Design of Experiment for Solar Water Heater Performance Analysis

DEVELOPMENT OF A SOLAR COLLECTOR/SOLAR WATER HEATING SYSTEM TEST CENTER IN IRAN

COMPARATIVE STUDIES ON THERMAL EFFICIENCY OF SINGLE AND DOUBLE GLAZED FLAT PLATE SOLAR WATER HEATER

Thermodynamic optimisation of an open air solar thermal Brayton cycle with fixed temperature constraints

Numerical Study on the Characteristics of a Specially Designed Rectangular Tube Absorber Photovoltaic Thermal Collector (PVT)

SUMMARY AND CONCLUSION

Research Article Experimental Study of Thermal Performance of One-Ended Evacuated Tubes for Producing Hot Air

CHAPTER - 3. Exergy Analysis of Solar Heating Devices

Energy and Exergy Analysis of Evacuated Tubes Solar Air Collector With Micro- Heat Pipes Arrays (MHPA)

Experimental Study of the Double-Pass Solar Air Collector With Staggered Fins

Optimization of Thermosiphon Solar Water Heating systems working in a Mediterranean Environment of Cyprus

Guidance page for practical work 1: modeling of a thermodynamic solar plant

Performance Evaluation of Solar Assisted Heat Pump Water Heating System

OPTIMIZATION OF PARAMETERS FOR HEAT RECOVERY STEAM GENERATOR (HRSG) IN COMBINED CYCLE PLANTS

Performance Evaluation of an Integrated Hybrid Photovoltaic/Thermal (PV/T) Greenhouse

A STUDY ON PERFORMANCE OF SOLAR SEAWATER DISTILLATION SYSTEM WITH AN AUXILIARY HEAT SOURCE FROM SOLAR COLLECTOR

DESIGN AND MODELING THE Φ-F

Performance Evaluation of Molten Salt Cavity Tubular Solar Central Receiver for Future Integration with Existing Power Plants in Iraq

Thermal performance evaluation of an integrated photovoltaic thermal-phase change material system using Taguchi method

THE EFFECT OF USING SMALL CYLINDRICAL ALUMINUM PIECES AS A PACKING MATERIAL ON THE DOUBLE PIPE HEAT EXCHANGER PERFORMANCE

EXPERIMENTAL DEVELOPMENT TO DETERMINE TIME CONSTANT FOR POLYMER COLLECTOR

AR No. # - Solar Thermal

ASSESSMENT OF R290 AS A POSSIBLE ALTERNATIVE TO R22 IN DIRECT EXPANSION SOLAR ASSISTED HEAT PUMPS

Exergetic Analysis and Optimisation of a Parabolic Dish Collector for Low Power Application

Thermal Performance and Cost to Produce 90 C-Hot Water of Solar Thermal Collector and Hybrid Photovoltaic Thermal (PVT) Collector Systems

COMPARISON OF THERMAL PERFORMANCE OF DIFFERENT WALL STRUCTURES

DESIGN AND EXPERIMENT OF PARABOLIC TROUGH COLLECTOR WITH NORTH-SOUTH ORIENTATION

Solar distillation is one

Performance Evaluation of Flat Plate Solar Collector (Model Te39) In Bauchi

Nanoparticles Enhanced Phase Change Material (NPCM) as Heat Storage in Solar Still Application for Productivity Enhancement

EXERGETIC ANALYSIS OF SOLAR AIDED COAL FIRED (210MW) THERMAL POWER PLANT

SOLAR WATER HEATING SYSTEM PERFORMANCE CHARACTERISTICS AT 40 0 C COLLECTOR TILT ANGLE USING HALOGEN BULB UNDER DIFFERENT RADIATION INTENSITY

EXPERIMENTAL STUDY ON SOLAR HEATING BY NATURAL HEAT CONVECTION AND RADIATION

Available online Journal of Scientific and Engineering Research, 2017, 4(1): Research Article

THERMAL AND ELECTRICAL PERFORMANCES OF A NEW KIND AIR COOLED PHOTOVOLTAIC THERMAL SYSTEM FOR BUILDING APPLICATION

Transient Performance Analysis of a Model Building Integrated with a Trombe-Wall

Experimental Investigation of Heat Transfer Enhancement of a Double Pipe Heat Exchanger with Helical Fins in the Annulus Side

WATER BASED PHOTOVOLTAIC THERMAL (PVT) COLLECTOR WITH SPIRAL FLOW ABSORBER: AN ENERGY AND EXERGY EVALUATION

Performance Analysis of Sea Water Solar Still To Produce Fresh Water and Salt Using Flat Plate Collectors

Solar Water Heater with Rotating Reflectors and Light Dependent Resistor (LDR)

Heat Transfer Analysis Collector

Efficiencies of flat plate solar collectors at different flow rates

Feasibilty of Wind-Solar Hybrid System for Cleveland, Ohio, USA

Study of Performance of Solar Photovoltaic Thermal Collector at Different Temperatures

Fabrication and Experimental Investigation of PCM Capsules Integrated in Solar Air Heater

MODELING THERMODYNAMIC ANALYSIS AND SIMULATION OF ORGANIC RANKINE CYCLE USING GEOTHERMAL ENERGY AS HEAT SOURCE

Renewable Energy Technology MJ2411

PERFORMANCE STUDY OF SOLAR STILLS WITH VARIOUS ABSORBING MATERIALS AND A SENSIBLE HEAT STORAGE MEDIUM

Experiment Study & Analysis of Solar Air Heater With Offset Fin.

Research Article. An Experimental Study of a Single Surface Solar Water Distiller

High Quality. UniPlate. Solar Collectors ENERGY SYSTEMS. Solartechnik Prüfung Forschung

Estimate the size of the solar and hydro power resources in kw. [5 Marks]

Design, construction and evaluation of a system of forced solar water heating.

BASIC EUROPEAN GLAZED COLLECTORS & SOLAR DOMESTIC

A SIMULATION OF THE THERMAL STORAGE PERFORMANCE OF THE METAL FIN EMBEDDED CONCRETE

CAE 331/513 Building Science Fall 2017

Performance Study of Solar Air Heater with Baffled Duct

Conversion Design of Solar Houses from Active to Passive

Performance Improvement of Shallow Solar Pond using Nanoparticles

Economical and Environmental Effects of Thermal Insulation Thickness in Four Different Climatic Regions of Turkey

Case Study of Performance of Hybrid Solar Photovoltaic- Thermal Water Heating System in Sokoto, Nigeria

EXERGY AND ENERGY ANALYSIS OF PHOTOVOLTAIC THERMAL (PVT)WITH AND WITHOUT FINS COLLECTOR

PERFORMANCE EVALUTION OF LIQUID FLAT PLATE COLLECTOR BY COMPARING THE NORMAL WATER WITH NaCl SOLUTION AS A WORKING FLUID

A Solar Wall System Utilized in Rural Houses of Northeast China

Thermodynamic analysis of a direct expansion solar assisted heat pump water heater

Performance Improvement in Solar Evacuated Glass Tube Collector

Experimental Analyses on Parabolic Solar Collector at Various Operating Conditions

COMPARATIVE ANALYSES OF TWO IMPROVED CO 2 COMBINED COOLING, HEATING, AND POWER SYSTEMS DRIVEN BY SOLAR ENERGY

Comparative study of parabolic trough collector through MWCNT/H 2 o nanofluid and water

System Cooling of Outdoor Wi-Fi Antenna

Performance enhancement of solar air collectors applied for drying processes

Design and Experiments of a Solar Low-temperature Hot Water Floor Radiant. Heating System 1

TECHNICAL AND ENVIRONMENTAL EVALUATION OF HEAT TRANSFER FLUIDS USED IN SOLAR POWER TOWERS

Solar-biomass drying system for para rubber sheet

Transcription:

International Journal of Engineering Research and Development e-issn: 2278-067X, p-issn: 2278-800X, www.ijerd.com Volume 11, Issue 03 (March 2015), PP.66-72 The Effects of Tempered Glass with Low Iron Oxide (Fe 2 O 3 ) Content on the Efficiency of Solar Air Heater Yusuf Bilgiç 1, Cengiz Yıldız 2 1 Ph.D Research Assistant, Department of Mechanical Engineering, Fırat University, 23119, Elazig, Turkey 2 Professor, Department of Mechanical Engineering, Fırat University, 23119, Elazig, Turkey Abstract:- In this study, the effect of glass cover on the energy and exergy efficiencies of conventional type solar air heater was investigated experimentally. Classic and tempered low iron glass were used as a glass cover. Two of collectors whose dimensions are 900x1900x170mm 3 were used in the experiments. The experiments were conducted at the air flow rates of 0.02, 0.03, 0.04 and 0.05 kg/s. Energy and exergy efficiencies were evaluated regarding to experimental results. As a result of the experiments, it was found that energy efficiency of the collector equipped with tempered glass with low iron oxide content increases by an amount of 4.5%- 5.3%. In case of exergy efficiency, an increase was also observed between 0.4 and 0.82 percent. Keywords:- Solar energy, Solar air heater, Tempered Glass I. INTRODUCTION Solar air heaters consist of four parts: transparent cover, absorber surface, and insulation and collector case. The fundamental function of the transparent cover is to prevent heat loss via convection. In addition, it also prevents the collector from harmful external conditions. Various transparent materials are used for the transparent cover. Glass is the most common among these different materials. The ratio of sunlight that can pass through glass is %80-90. Whereas the remaining %10-20 is reflected back. The reason for reflection is the amount of iron oxide (Fe 2 O 3 ) in the glass. Hence, a low iron oxide amount is desired in glass. Another property that is desired in glass is resistance against external factors and thermal stress. Hence, tempering process is applied to glass in order to increase its strength [1]. Kurtbaş and Durmuş [2] have carried out the energy and exergy analyses of a solar air heater. They have used four different types of collectors in their study. They have worked with two different flow rates of 0.028 kg/sec and 0.012 kg/sec. Maximum efficiency was determined for traditional type collector as %16. Whereas maximum efficiency for Type-3 was determined as %67. Esen [3] has experimentally examined the energy and exergy analyses of 4 types of double flow collectors. Type-1 of these collectors has been used without any obstruction whereas different types of obstructions have been used in the other 3. Uçar and İnallı [4] have carried out the energy and exergy analyses of 5 types of collectors in their study. They have determined that the highest irreversibility ratio was that of the conventional type collector with 0.236 kw and that the exergy loss was %64.38. Whereas they have also determined that the lowest exergy loss was %43.91 for the collector with a 2 o inclined absorber surface. Akpınar and Koçyiğit [5] have carried out the exergy and thermal analyses of four different collector types. They have manufactured 3 collectors by placing the fins differently. Whereas the fourth collector was a conventional type collector. They have determined the 1st Law efficiency in Type-II in this study as %82 maximum and the 2nd Law efficiency as %44 maximum. Gill et.al. [6], have examined a low cost solar air heater experimentally and they have also carried out a cost analysis. They have used three types of collectors with double glass, single glass and one filled with iron shavings. They have observed that the efficiencies of single glass, double glass and bed type collectors in winter season with an air flow rate of 0.02 m 3 /s vary as %30.29, %45.05 and %71.68. Alta et.al. [7] have carried out the experimental thermal analyses for double glass finless collector (Type-I), double glass and finned (Type-II) and finned (Type-III) collectors. They have determined that the efficiencies of Type-II and Type-III to be greater than that of Type-I; the highest irreversibility ratio was determined in Type-I, whereas the lowest irreversibility ratio was determined in Type-II. Löf and French [8] have examined the strength of solar collectors with tempered glass covers against hail. Hey have stated that the largest area in the studied region covered 540 m2 with panels for which 700 tempered glass covers have been used. They have observed that only 7 of panels were broken after the hail and that 2 of the 54 panels with untempered glass have been broken. The effect of glass cover on efficiency has been examined in this study. Energy and exergy efficiencies of the collectors have been calculated according to the acquired results. 66

II. EXPERIMENTAL SET UP The solar air heaters used have dimensions of 900x1900x170 mm. The bottom and side sections have been insulated with 50 mm thick glass wool. The interior of the collector has been painted matte black. A 4 mm classic window glass has been used in one of the collectors as glass cover, whereas 4 mm tempered glass with low iron oxide content (TGLIO) has been used in the other. The iron oxide content of the used TGLIO is less than %0.02. Whereas in normal glass (NG) this ratio is about %10. Fig.1 shows the schematic diagram of the solar air heater with TGLIO that was used in the experiments. A 1800 rev/min radial fan with 0.75 kw power that has a maximum air flow rate of 1.8 kg/s has been used to provide air movement in the collectors. ABB brand ACS-150 model 0.75 kw inverter has been used to control the fan speed. The measurement devices used in the experimental setup and their properties have been given in Table I. Fig.1 : Experimental setup. a) Schematic, b)photography Table.I: The measurement devices used in the experimental setup Parameter Measuring Devices Brand, Model Sensitivity Error Solar Solarmetre Kipp&Zonen 5-20 <20 W/m 2 Radiation CMP3 µv/w/m² Temperat ure Digital Thermometer Elimko E-680 0,01 o C ±0,1 o C Air Hot Wire CEM DT-8880 0,01 m/s ±%1 Velocity Anemometer Wind Velocity Thermo Anemometer Prova AVM-07 0,01 m/s ±%3 The experimental setup was assembled on the terrace floor of Department of Mechanical Engineering (Fırat University, Elazığ). The heaters were placed facing south at an angle of 38 degrees. The experiments were carried out between the hours of 08:00-18:00. The measurements were taken with one hour intervals. III. THERMAL ANALYSIS Energy efficiency can be calculated as the ratio of the available heat to the solar radiation on the collector [2,3,4,5]. 67

Q mc ( T T ) (1) c p o i Qc en (2) ( IA ) C mc p ( To Ti ) en (3) ( IA ) C According to these assumptions, the energy and exergy equalities of the system are as below [2,3,4,5]. E i E o (4) Ex i Ex o Ex (5.a) Ex heat Ex work Ex mass, i Ex mass, o Ex (5.b) General exergy equality can be expressed as below using Eq. (5.b). 1 T e Q s W m ii m oo Ex T (6) s The input (ψ i ) and output specific exergy (ψ o ) can be written as such; h h T S S i i e e i e (7) h h T S S o o e e o e (8) If Equation (7) and (8) are placed inside equation (6); 1 T e Q s m ho hi Te So Si Ex (9) T s Is obtained. The solar energy absorbed by the absorber surface is as follows: Q I A s c The enthalpy and entropy changes of the air in the collector; h cp T f, o T (11) f, i T fo, P s c ln R ln o p (12) T fi, P i When Equations (10),(11) and (12) are placed in equation (9) T T, 1 e fo P I A mc T, T, mc T ln mrt ln o c p f o f i p e e Ex T T s fi, P i (13) Is obtained. Exergy loss (irreversibility) can be calculated as below: Ex T e S gen (14) Dimensionless exergy loss [2,3,4,5]; Ex Ex D Qc (15) Is thus obtained. Whereas exergy efficiency [2,3,4,5] is expressed as; (10) 68

1 ex The Effects of Tempered Glass with Low Iron Oxide (Fe 2 O 3 ) Content on the Efficiency of Solar Air Heater TS e gen 1 Te / Ts Q (16) s IV. RESULTS AND DISCUSSION In this study, the effect of classical glass and low iron content tempered glass as transparent cover for solar air heaters on energy and exergy efficiencies have been experimentally examined. 2 collectors were used in the experiments. The experiments were carried out with air flow rates of 0.02 kg/sec, 0.03 kg/sec, 0.04 kg/sec and 0.05 kg/sec during the dates of 31.08.2012 and 07.09.2012 at the city of Elazığ in Turkey under equal weather conditions. The experiments were repeated for two days for all flow rates. Fig.2 shows the average radiation values for the 8 days during which the experiment was carried out. The radiation value was measured as 285 W/m 2 at 08:00 in the morning as 832 W/m 2 at13:00 and as 61 W/m 2 at 18:00. Fig.2: The solar radiation as a function of day times Fig.3 shows the change in time of the available heat amount that has been calculated using Eq. (1). The highest available heat was obtained in the heater in which TGLIO was used at m=0.06 kg/s. The available heat varies between 30,5 J/s and 498,9 J/s for this case. Whereas the average available heat is 321 J/s. The lowest available heat was observed in the heater in which NC was used at a flow rate of m=0.02 kg/s. The available heat varies between 24.5 J/s and 335 J/s for this case. The average available heat has been determined as 217 J/s. Fig.3: The useful heat rate as a function of day times 69

Fig.4 shows the change in time of the energy efficiencies that have been calculated using Eq (3). Similar to available heat, energy efficiency was also observed to be highest in the heater with TGLIO at a flow rate of m=0.05 kg/s. The average energy efficiency for this case was %43.5. Whereas energy efficiency average was determined as %38.2 in the heater with NC at a flow rate of m=0.05 kg/s. The lowest energy efficiency was calculated as %29.3 on average at a flow rate of m=0.02 kg/s. The average efficiency was determined as % 33.8 in the TGLIO used solar heater at the same flow rate as. Fig.4: The energy efficiency as a function of day times The change with time in exergy efficiency calculated using Eq (16) has been shown in Fig.5. The source temperature used in the calculation (Ts) is the temperature of the absorber surface. The highest exergy efficiency was observed in the heater with TGLIO at a flow rate of m=0.02 kg/s. The average exergy efficiency for this case was %6.95. Whereas the average exergy efficiency for the heater with NC at this flow rate was % 6.13. It has been observed that the exergy efficiency was lowest with a value of % 4.1 in the heater with NC at an air flow rate of m=0.05 kg/s. Whereas the efficiency was observed as % 4.5 in the heater with TGLIO. Fig.5: The energy efficiency as a function of day times 70

Dimensionless exergy ratio was calculated using Eq (15). According to the acquired results, Fig.6 shows the change in dimensionless exergy ratio with time for each flow rate. The lowest dimensionless exergy ratio was observed in the heater with TGLIO at an air flow rate of m=0.05 kg /s. The dimensionless exergy ratio average for this case was determined as 0.1924. Whereas the highest dimensionless exergy ratio average was calculated as 0.2325 in the heater with NC at an air flow rate of m=0.02 kg/s. Fig.6: The dimensionless exergy ratio as a function of day times Experimental results put forth that low iron content tempered glass is more efficient thermally in comparison with normal glass. Another property of TGLIO is that it shatters into tiny pieces upon breaking. The status of the glasses dropped to a concrete floor from a height of 3 meters has been shown in Fig.7. Fig.7: Normal and Tempered glass shards V. CONCLUSIONS In this study, the effects of classical glass and low iron content tempered glass as transparent covers in solar air heaters on energy and exergy efficiencies have been examined experimentally. As a result of the experiments, it was found that energy efficiency of the collector equipped with tempered glass with low iron oxide content increases by an amount of 4.5%-5.3%. In case of exergy efficiency, an increase was also observed between 0.4 and 0.82 percent. It was observed that the available heat, energy efficiency and exergy efficiency of heaters with TGLIO were higher. The main reason for this is that the radiation reflecting from the glass covers decreases as the ironoxide (Fe 2 O 3 ) amount decreases. In addition, tempered glass is more resistant to external weather conditions in comparison with normal glass. Another feature of TGLIO is that the glasses do not break as blocks upon impact. This glass shatters into tiny pieces. This is important in terms of safety. 71

NOMENCLATURE A Surface are (m 2 ) Cp Specific heat (J/kg K) E Energy rate (W) Ex Exergy rate (W) Ex D Dimensionless exergy loss (dimensionless) Ex Rate of irreversibility (W) h Enthalpy (J/kg) I Solar radiation (W/m2) m Mass flow rate (kg/s) P Fluid pressure (Pa) R Universal gas constant (J/kg K) Useful heat rate (W) Q c Q s Incident energy in the collector area (W) s Entropy (J/kg K) S gen Entropy generation rate (W/kg K) T Temperature ( o C) W α η en η ex τα ψ Work rate or power (W) Absorptivity (dimensionless) Energetic efficiency (dimensionless) Exergetic efficiency (dimensionless) Effective transmission (dimensionless) Specific exergy (J/kg) A. SUBSCRIPTS a Air c Collector e Environment f Fluid i Inlet o Outlet gen Generation ACKNOWLEDGEMENT Authors would like to thank The Scientific Research Project Unit of Firat University (MF-11-37) for the financial support REFERENCES [1] Uyarel, A., Y., & Öz,E.,S., Güneş Enerjisi ve Uygulamaları., 2nd ed., Birsen Yayınevi, Ankara, Turkey, 1988. [2] İ.,Kurtbaş, A., Durmuş, Efficiency and Exergy Analysis of A New Solar Air Heater, Renewable Energy,vol.29, pp.1489 1501,2004. [3] H.,Esen, Experimental Energy and Exergy Analysis of A Double-Flow Solar Air Heater Having Different Obstacles on Absorber Plates, Building and Environment, vol.43, pp.1046 1054,2008. [4] A.Ucar, and M. İnallı, Thermal and Exergy Analysis of Solar Air Collectors With Passive Augmentation Techniques, International Communications in Heat and Mass Transfer, vol.33, pp.1281 1290, 2006. [5] E.K.Akpınar and F. Koçyiğit, Energy and Exergy Analysis of A New Flat-Plate Solar Air Heater Having Different Obstacles on Absorber Plates, Applied Energy, vol.87, pp.3438 3450,2010. [6] R.,S., Gill, S.,Sukhmeet and P.S.,Parm, Low Cost Solar Air Heater, Energy Conversion and Management, vol.57, pp.131 142, 2012. [7] D.Alta, E.Bilgili, C.Ertekin and O. Yaldız, Experimental İnvestigation of Three Different Solar Air Heaters: Energy and Exergy Analyses, Applied Energy, vol.87, pp.2953 2973,2010. [8] G. O.G. Löf and R. R. French, Hail resistance of solar collectors with tempered glass covers, Solar Energy, vol.25-6, pp.555-561, 1980. 72