SYSTEM W-H 1100 Wall cladding Metal product
:::: 3 WALL CLADDING SYSTEM W-H 1100 APPLICATION AREA n Acoustic element n Cladding or covering element n Architectural room-design element n Combination of different requirements BENEFITS n Certified system n Small offset distance n Space saving n Light-weight type n Simple installation (alignment) and disassembling n Standard subconstruction n Versatile application n Cost efficient and fast to install n For extensive acoustic requirements MAINTENANCE AND ENVIRONMENT Wall claddings by Armstrong are highly attractive interiordesign elements. They are washable, making them easy to clean. Armstrong s dirt-repelling powder coating has proven itself to be a hard-wearing surface finish for many decades. The solvent-free production process also makes our wall claddings innocuous from an ecological and health-related viewpoint. QUALITY AND SERVICE Armstrong s production facilities guarantee optimal capacity and the remarkably flexible production of wall claddings. Efficiently-organised processes, continuous quality management and a global network of subsidiaries and distribution partners ensure orders are delivered on time. PROJECT: Learning Commons Building - Manchester University (UK) :::::::: ARCHITECT: Sheppard Robson PROJECT: University of Texas at San Antonio, Multidisciplinary Studies Building :::::::: ARCHITECT: Alvidrez Architecture Inc., San Antonio, TX
:::: 5 SPECIFICATION STANDARD PERFORATION PATTERNS CLEANING System Panels Material Coating System wall cladding system W-H 1100 hook-on, without visible fasteners offset distance standard 60 +17/-8 mm suspension at the vertical sides of the panel Galvanized steel sheet 1.0 mm (aluminium on request) Powder coating on the visible side in RAL or NCS Dust should be removed from the painted surface by wiping with a clean soft cloth. More stubborn marks should be removed with a mild household detergent in warm water. Excessive use of water should be avoided. The use of abrasive cleaners or scrubbing of the painted surface is not recommended. Execution Joints Rectangular panels square edged with standard notch for W-H 1100 Standard black gasket and spacers 5 mm at the horizontal and vertical sides of the panel Rd 1522 Rg 2516 COLOUR The W system series is available in all the colours of the RAL and NCS palette. Special metallic finishes can even be offered on request. Perforation Inlay Dimension According to the perforation overview Standard with black acoustic fleece (further inlays on request) Panel length 600-3000 mm Panel width 275-1000 mm Subconstruction fixed with wall anchors to raw wall, unevenness of the raw wall can so be absorbed by the wall anchors CHOICE OF PANEL TYPE - 1300 mm type A panel dimension upright - 2500 mm type B - 3000 mm type C panel alignment special sizes reclined panel dimension - 3000 mm type D special sizes ACOUSTIC PERFORMANCE The acoustic effect of wall cladding systems is often of central importance. Smooth walls will reflect sound while perforated ones tend to be sound absorbent, depending on their design. We recommend the use of black acoustic fleece as a sound-absorbing inlay with acoustic mat for our wall claddings. Reverberation times, and consequently the sound level, can be reduced considerably in this way. Functional, intelligently-designed acoustic solutions characterise every Armstrong wall cladding: noise is absorbed where it could be distracting, while speech and sound is directed to where it is desired. Whatever your needs for the acoustic properties of a room, Armstrong wall claddings will satisfy your expectations. Detailed information will be given by your Armstrong adviser. HUMIDITY EXPOSURE Not greater than 70% RH @ 16-23 C for long term exposure. Not greater than 95% RH for short term exposure during building site installation. QUALITY STANDARD Armstrong is a certified EN ISO 9001:2008 Quality Assured Manufacturer. All wall cladding and grid items are manufactured to tolerances and quality standards as Armstrong ceilings. Where differences exists between this and any expressed or implied architectural specificaitons or requirements then Armstrong s manufacturing standards will prevail unless stated otherwise. ENVIRONMENTAL Our metal panels have an average of up to 30% recycling content. Our European manufacturing plants are certified to: EN ISO 9001:2008 ISO 14001:2004 + Cor. 1:2009. Armstrong is a member of TAIM (Technical Association of Industrial Metal Ceilings). execution type A01 - A10 execution type B01 - B10 execution type C01 - C10 on request execution type D01 - D10 on request SERVICES INTEGRATION Metal panels can be supplied with factory produced cut outs and apertures for the integration of building services equipment.
6 :::: OVERVIEW AND CONSTRUCTION standard execution one single line upright one single line reclined one single panel Panels type A01 - A10 length A: min. 600 / max. 1300 mm width B: min. 275 / max. 1000 mm standard execution one single line upright one single line reclined one single panel Panels type B01 - B10 length A: min. 1301 / max. 2500 mm width B: min. 275 / max. 1000 mm standard execution one single line upright one single line reclined one single panel Panels type C01 - C10 length A: min. 2501 / max. 3000 mm width B: min. 275 / max. 1000 mm standard execution one single line upright Panels type D01 - D10 length A: min. 600 / max. 3000 mm width B: min. 275 / max. 1000 mm one single line reclined one single panel PROJECT: Learning Commons Building - Manchester University (UK) :::::::: ARCHITECT: Sheppard Robson
:::: 9 PERSPECTIVE VIEW Detail A connector for gasket 5 mm black along and across connector for C-wall profile 8 x self drilling screw eco-drill 3.5 x 9.5 mm raw wall Detail B Raw wall plastic dowel UX-10 and screw 4 x self drilling screw eco-drill 3.5 x 9.5 mm Detail C corner- Raw wall 4 x self drilling screw eco-drill 3.5 x 9.5 mm plastic dowel UX-10 and screw standard panel W-H 1000 Detail D assembling of for supporting bracket for 4 x self drilling screw eco-drill 3.5 x 9.5 mm supporting bracket for length = 3 000 mm Detail E for PROJECT: Dubai International Airport. Dubai (UAE) :::::::: ARCHITECT: Aéroport de Paris (ADPi), Paris, France Item No. BPM 311200 BPM 311201 BPM 315623 BPM 315626 BPM 315627 BPM 315628 BPM 315624 BPM 315625 BPM 311191 Description plastic dowel UX-10 screw for plastic dowel UX-10 connector for for supporting bracket for C- and corner- self drilling screw eco-drill 3.5 x 9.5 mm for supporting bracket for
10 :::: :::: 11 WALL PANEL TYPES Type A01 length A: min. 600 / max. 1 300 mm width B: min. 275 / max. 1 000 mm 2 suspension points on each long side of the panel, upright Type C01 length A: min. 2 501 / max. 3 000 mm width B: min. 275 / max. 1 000 mm 4 suspension points on each long side of the panel, upright Type B01 length A: min. 1 301 / max. 2 500 mm width B: min. 275 / max. 1 000 mm 3 suspension points on each long side of the panel, upright Type D01 length A: min. 600 / max. 3 000 mm width B: min. 275 / max. 1 000 mm 2 suspension points on each short side of the panel, reclined 11
12 :::: :::: 13 CONNECTION DETAILS VERTICAL HORIZONTAL Detail F connection to the ceiling Detail G visible connection to the top Detail H connection to the top with profile Detail O lateral connection to the wall Detail P visible lateral connection end profile for for for supporting bracket for Detail Q lateral connection to the door frame supporting bracket for Detail R inside corner with gap Detail I connection to the windowsill Detail J connection to the floor Detail K visible connection to the bottom windowsill for for for door leaf door frame supporting bracket for Detail S outside corner with special panel Detail L connection to the bottom with angle Detail M connection to the door frame Detail N connection to lintel supporting bracket for for for for supporting element for special panel angle door frame lintel (metal plate) door leaf
14 :::: PANEL DISMOUNTING Starting position n installed wall cladding n each panel can be dismounted separately without a tool, starting from the top n panels should only be touched with clean gloves Step 1 n the panel must be lifted up vertically at min. 10 mm n keep attention to existing installations Step 2 n the panel can be removed n store the panel carefully PROJECT: Dubai International Airport. Dubai (UAE) :::::::: ARCHITECT: Aeroport de Paris (ADPi), Paris, France