Compliance. Safety. Durability.

Similar documents
New York City RS 6.1 Photoluminescent Exit Path Markings

The easiest way to comply with local law 26. A Review of New York City Building Code Reference Standard RS 6-1

2009 IBC Section 1024 Approved Luminous Egress Path Markings

CONSTRUCTION TECHNOLOGY UPDATE

When the Lights go out Ours come ON

2009 IBC/IFC Photoluminescent Signs & Pathway Marking Systems Frequently Asked Questions

Powered by glowzone TM. Dependable lighting for safe egress. Safe egress when emergency electrical lighting and signage fail.

Compliance Guide for Fire Code

Luminous Egress Path Markings

UL 1994 Listed Code Compliant Photoluminescent Egress Path Markings per IBC & IFC

IBC/IFC Egress Path Marking System Compliance Manual

Instructions for installation Everlux Egress Path Marking System

BRADYGLO EMERGENCY EGRESS MARKING HANDBOOK

SPECIFICATIONS Aluminum Stair Nosing - Bull Nosing

(Note: This document is the same as been forwarded to be published in the City Record for public hearing and comment)

REFERENCE STANDARD RS-6 MEANS OF EGRESS

PROMULGATION OF THE NEW YORK CITY BUILDING CODE REFERENCE STANDARD RS 6-1 AND RS 6-1A IN RELATION TO PHOTOLUMINESCENT EXIT PATH MARKINGS

PROMULGATION OF THE NEW YORK CITY BUILDING CODE REFERENCE STANDARD RS 6-1 AND RS 6-1A IN RELATION TO PHOTOLUMINESCENT EXIT PATH MARKINGS

PROMULGATION OF THE NEW YORK CITY BUILDING CODE REFERENCE STANDARD RS 6-1 AND RS 6-1A IN RELATION TO PHOTOLUMINESCENT EXIT PATH MARKINGS

A field perspective-what the inspector looks for during a Racking inspection.

FLOOR MARKING GUIDE. Regulations, color standards, tips, solutions and more!

Design Aid for Barrier-Free Accessibility in Existing Buildings

BUILDING/FACILITY ACCESSIBILITY CHECKLIST. Lessee. Lessor

EGRESS AZMIR SULTANA NICOLAS MIMU SAKUMA EDWIN VEGA CHAMORRO

Section 1 OBC FADS /13 Access to Parking Areas

CITY OF DANA POINT SITE ACCESSIBILITY AND PARKING B103 SITE INTRODUCTION

SITE ACCESSIBILITY AND PARKING

EQUIVALENT INITIAL FIRE SAFETY ASSESSMENT

GLO BRITE FRAMED SIGNS

Site Accessibility Survey & Transition Plan

2020 DISPLAY REGULATIONS

How to Prepare Your LSE Report

2015 IBC Exit Systems

EGRESS CHAPTER ,500 3 Over 2,500 4 OCCUPANT LOAD REQUIRED MEANS OF EGRESS

HERMIT S REST GRAND CANYON NATIONAL PARK BUILDING CODE REVIEW

Project Address Applicant: (Please Print) Plan review Engineer: Phone: Date

MAIN CATALOG Photoluminescent Safety Products and Bumper Guards

ICC CODE CORNER 2012 IFC Code & Commentary

Florida Accessibility Code for Building Construction

2006 International Building Code Modified for the 2007 Florida Building Code 6/5/06

DEPARTMENT OF PUBLIC SAFETY AND CORRECTIONS. Public Safety Services ADA-ABA COMMENT ASSISTANCE GUIDE

2012 IBC Exit Systems

City of Walnut Creek Development Review Services 1666 N. Main Street, Walnut Creek, CA (925) phone (925) fax

SAFEGUARDS DURING CONSTRUCTION

2600SEG135 SAFETY STANDARD FOR INDUSTRIAL LADDERS AND STAIRCASES IN BUILDINGS

MAIN CATALOG Photoluminescent Safety Products and Bumper Guards

Overview of Revised School Regulation

311.7 Stairways Width Headroom. Exception: Walkline Stair treads and risers Tread depth.

Description Accessibility Standards. AODA OBC 2015 Ramps

CITY OF OCEANSIDE. Single Family Dwelling Stairways/Guards. Informational Bulletin

Plan Check No. A. ELEVATORS

PRODUCTS. USLED - Safety Products - Marker & Delineators GLOW STEP. Reduce slips and falls with recycled light

(Statute, Rule, FBC, Industry) FBC 406.3, see also FBC No provisions in FBC or FS

Americans with Disabilities Act Accessibility Survey

VISIBLY BETTER. Photoluminescent Emergency Path Marking Solutions for Indoor and Outdoor Use. IFC/IBC, NYC LL and NFPA Compliant Guidance Systems

PSA / PSPA Guide to the Use of Photoluminescent Safety Markings. Part One: Egress Markings In Stairwells

Kinesik Engineered Products Inc. 4/22/16 1

DIVISION 10 SPECIALTIES

GUIDELINES FOR THE DEVELOPMENT OF UNIVERSALLY DESIGNED UNITS. New Construction & Rehab

Certificate of Occupancy Inspection Checklist Change of Use Group or Occupancy

TOWN OF PERINTON 1350 TURK HILL ROAD. FAIRPORT, NEW YORK (585) , Fax: (585) ,

Florida Accessibility Code for Building Construction

Accessible Means Of Egress

1. Add Carpeting to this scope of work as outlined per the schedule of alternates.

The Building Codes A.R.E. Building Design and Construction Exam Prep

10. Transportation Facilities.

DECK CONSTRUCTION REQUIREMENTS

C.R. LAURENCE CO., INC. Intelli-Track SPS. Phase One - Installation Instructions

SUPPLEMENTAL ACCESSIBILITY NO. 5 PLAN REVIEW CHECKLIST

LINCOLN COUNTY REQUIRED INSPECTIONS (Last updated August 23, 2017)

RESIDENTIAL STAIRWAYS, HANDRAILS,

PRESCRIPTIVE COMPLIANCE METHOD

Adult Family Home Inspections

Direct Service Done Right. Stair Treads + Nosings Catalog

LIFE SAFETY 101. Architecture Interior Design Planning Sustainable Design

SECTION METAL STAIRS

1. Refer to SECTION SIGNS and reolace entire document with aftached new soecification. 5. Refer to Electrical Drawing E3.1

LAPEYRE STAIR PRODUCT LINE

Savard Labor & Marine Staffing, Inc. Fall Prevention Program Rev3/14

Applying the Building Code During Design

SECTION GYPSUM BOARD ASSEMBLIES

The Catholic University of America Cardinal Station Washington, DC INTERIOR SIGNAGE GUIDELINES. January 21, 2009 (Revised)

IWF Safety Guidelines

Work Group Item Stairways serving an occupant load of less than 50 shall have a width of not less than 36 inches (914 mm).

WORKING AT ELEVATED PLACES Working on Roofs

SECTION MANUAL FOUR FOLD DOORS MODEL 38 DECORATIVE PANEL DESIGN

WINDOW AND DOOR REPLACEMENT SAMPLE PLAN

Why do we need to learn about Stairs

INFORMATIONAL HANDOUT FOR FINISHING A BASEMENT

SECTION 10.0 WAYFINDING STANDARDS AND GUIDELINES

2007 Title 24 Accessibility Code Updates and ADA Issues

RESIDENTIAL REMODELING AND BASEMENT FINISH

Standard for Bleachers, Folding and Telescopic Seating, and Grandstands

HERITAGE MIDDLE SCHOOL. Overview: Livingston School District Heritage Middle School

a. Plaques with fixed panel. B. Related Sections: The following sections contain requirements that relate to this section:

APPENDIX B SIGNAGE STANDARDS

STAIRWAYS, HANDRAILS, AND GUARDRAILS (RESIDENTIAL)

EASY RIDER (MUSTANG) EASY RIDER (PONY) EASY RIDER (ZEBRA) EASY RIDER (BRONCO)

B. Polyethylene samples shall be submitted for Owner approval of color and quality.

Transcription:

Compliance. Safety. Durability. Products that install faster and last longer. MEA-Approved Photoluminescent Exit Path Markings for NYC Local Law 26 Compliance

Code compliant products: engineered The BradyGlo Advanced Safety Guidance System. In an emergency situation, people need to move out of a dark building quickly and safely. BradyGlo photoluminescent markings are a fail-safe technology that illuminates an evacuation route, guiding people around obstacles, along stairs, through hallways and to the safest, nearest exit. BradyGlo photoluminescent products stick and stay stuck. Because we manufacture our own materials, we can ensure the durability and quality of all BradyGlo photoluminescent materials with products that address specific needs for NYC Local Law 26 code compliance. Brady has over 90 years of experience in developing, engineering, and manufacturing safety markings and equipment for a variety of industries. We understand your needs for quality, safety, durability, and easy installation. Engineered to save time and money. Our exclusive High-Tack adhesive is as much as 30% stronger than other pressure sensitive adhesives, reducing costly maintenance. Pre-cut products avoid time-consuming hand cutting and help ensure a correct and consistent configuration. Low-profile construction of pressure sensitive adhesive products easily conforms to handrails, stand pipes, and other circular shapes for faster application. MEA-approved; made in the U.S.A. for NYC Local Law 26 compliance. Six-year limited warranty. Brady Professional Installation Services provide a complete and cost effective way to get the job done right on time and on budget. (See back for details.) 2 For more information on BradyGlo photoluminescent products and our 6-year limited warranty, visit www.bradyid.com/bradyglo.

to last, designed to save lives. New York City Local Law 26 How does it apply to your building? New York City Local Law 26, Reference Standard 6-1 and 6-1A, is a revision to the city s building code that requires all Class E commercial properties that are 75 feet or taller to retrofit their emergency evacuation stairwells with photoluminescent markings and signage on or before July 1, 2006. Class E commercial buildings are defined as a typical business occupancy group that consists of: Office buildings Banks Civic administration buildings Medical offices and more What must be marked to be NYC Local Law 26 compliant? The code outlines specific requirements for placement of photoluminescent signs and markings, including: Doors opening to exits or exit passageways Landings, perimeters, and individual stair steps located within exit passageways Obstacles and hazards located within exit passageways Directional guidance signs to vertical, horizontal, and final exits, plus Not an Exit door signs where applicable Handrails (not required for buildings with plans that were approved prior to July 1, 2006) Use this catalog as your one-stop guide to complete code compliance. We want to help you achieve code compliance quickly and easily, with products that will last for years. Everything you need for complete compliance with NYC Local Law 26 is included on the following pages, with guidelines to help you select the right products for your building. For more information, visit www.bradyid.com/bradyglo or call 1-877-842-7239. Use durable BradyGlo photoluminescent products for code-compliant markings that last. For more information on NYC Local Law 26 and code requirements for new construction, visit www.bradyid.com/bradyglo. 3

BradyGlo Advanced Safety Guidance System: A complete selection of photoluminescent products. BradyGlo photoluminescent products are specifically engineered to give you the right configurations for code compliance, while offering fast, easy installation and unsurpassed durability. Our complete product line also includes both self-adhesive and aluminum-backed materials, to accommodate any building surface or application method. Pre-cut, L-shaped stair markers for stair edges High intensity tape for the leading edge of stairs or landings, handrails, perimeters, and door frames Directional safety guidance signs High intensity hazard tape for marking obstacles Safety guidance signs for not an exit, intermediate exit, and final exit doors Door hardware markers How to choose the right BradyGlo photoluminescent products for your building: Self-Sticking Adhesive Tapes and Signs (MEA #218-05-M) Self-sticking adhesive tapes are lightweight, conformable and easy to install. These products require a clean, smooth, dry, non-porous surface for proper adhesion. Smooth but irregular surfaces, such as painted, non-porous concrete, can be accommodated; however, the surface irregularities will be visible through these products once applied. Aluminum-Backed Products (MEA #233-05-M and MEA #251-05-M) Aluminum-backed rigid products are used with a separate construction adhesive that is applied on-site. These products are the best choice for rough and/or porous surfaces. Aluminum-backed products will give a flush appearance, can be shaped to conform to irregularities and, if needed, bridge gaps when applied to non-flat surfaces. Both self-adhesive products and aluminum-backed products may be required where surface conditions vary within a single installation. Anti-Slip Products (MEA # Applied For) NYC Local Law 26 does not specify minimum slip-resistance requirements for photoluminescent products installed on walking surfaces, but other building codes may have specific slip-resistance requirements. For added safety, we recommend using anti-slip products when marking the leading edge of landings and the leading edge of stair steps. Save time and money with BradyGlo EZ-Release and EZ-Dispense photoluminescent product packaging Brady s exclusive packaging and adhesive liners make BradyGlo photoluminescent products easier to use while reducing costly product waste. The EZ-Release liner simplifies the process of removing the liner from the tape just peel and apply for fast, easy installation. For BradyGlo pressure-sensitive adhesive photoluminescent products in roll form, the Brady EZ-Dispense packaging allows you to dispense as you go, in only the amount you need. This dispenser eliminates unwieldy spiraling of the rolls and saves time during installation. 4 For more information on BradyGlo photoluminescent products and our 6-year limited warranty, visit www.bradyid.com/bradyglo.

Your one-stop source for NYC Local Law 26 compliance. 1 2 Directional Safety Guidance Signs High Intensity Tape 1 2 6 2 3 3 Door Hardware Markers 4 4 5 Safety Guidance Signs 5 6 L-Shaped Stair Markers High Intensity Hazard Tape For more information on NYC Local Law 26 and code requirements for new construction, visit www.bradyid.com/bradyglo. 5

BradyGlo photoluminescent products stick L-Shaped Stair Markers L-shaped stair markers are allowed as side edge markings on both horizontal sides of each step. GLOW-IN-THE-DARK PRE-CUT L SHAPED STAIR MARKERS Material MEA# Brady Material No. Size Qty./Pack Self-Sticking Adhesive MEA #218-05-M B-523 9 in. x 3 in. 56 Markers 81867 (28 Right/28 Left) Self-Sticking Adhesive Value Pack MEA #218-05-M B-523 9 in. x 3 in. 520 Markers 81868 (260 Right/260 Left) Aluminum-Backed* MEA #251-05-M B-861 9 in. x 3 in. 56 Markers 81708 (28 Right/28 Left) Aluminum-Backed* Value Pack MEA #251-05-M B-861 9 in. x 3 in. 520 Markers 81710 (260 Right/260 Left) Anti-Slip Self-Sticking Adhesive Applied For B-564 9 in. x 3 in. 56 Markers 81733 (28 Right/28 Left) Anti-Slip Self-Sticking Adhesive Value Pack Applied For B-564 9 in. x 3 in. 520 Markers 81735 (260 Right/260 Left) Anti-Slip Aluminum-Backed* Applied For B-875 9 in. x 3 in. Anti-Slip Aluminum-Backed* Value Pack Applied For B-875 9 in. x 3 in. *Apply with a construction-grade adhesive. 56 Markers (28 Right/28 Left) 520 Markers (260 Right/260 Left) 81736 81738 Photoluminescent Strip 2 Min Return 1/ Stair Markings High Intensity Hazard Tape Obstacles that protrude into the egress path such as standpipes, hose cabinets, wall projections, and restricted height areas are required to be outlined with appropriate markings. GLOW-IN-THE-DARK HIGH INTENSITY HAZARD TAPE Material MEA# Brady Material No. Size Qty./Pack Self-Sticking Adhesive MEA #218-05-M B-523 1 in. x 50 ft. 1 Roll 81869 Self-Sticking Adhesive Value Pack MEA #218-05-M B-523 1 in. x 250 ft. 1 Roll 81870 Min 6 6 Above Finish Floor Marking of Obstacles as per 2.2.5 Obstacles 6 For more information on BradyGlo photoluminescent products and our 6-year limited warranty, visit www.bradyid.com/bradyglo.

and stay stuck. High Intensity Tape Multiple uses for NYC Local Law 26 compliance include: Step markings, allowed on the entire horizontal leading edge of each step as a solid and continuous strip. Leading edge of landings, required on the entire horizontal leading edge of each landing as a solid and continuous strip the full length of the leading edge, or the same length as and consistent with the strips on the steps. Perimeter demarcation lines, intended to outline the egress path by providing low-location lines on both sides of the path, either on the floor or on the wall. Door frame markings, for which the tops and sides of the door frame of all intermediate and final exit doors shall be marked with a solid and continuous strip. Handrails (optional), to be marked with a solid and continuous strip. GLOW-IN-THE-DARK HIGH INTENSITY TAPE Material MEA# Brady Material No. Size Qty./Pack Self-Sticking Adhesive MEA #218-05-M B-523 1 in. x 50 ft. 1 Roll 81873 Self-Sticking Adhesive Value Pack MEA #218-05-M B-523 1 in. x 250 ft. 1 Roll 81874 Aluminum-Backed* MEA #251-05-M B-861 1 in. x 50 ft. 1 Roll 81706 Aluminum-Backed* Value Pack MEA #251-05-M B-861 1 in. x 250 ft. 1 Roll 81707 Anti-Slip Self-Sticking Adhesive Applied For B-564 1 in. x 50 ft. 1 Roll 81729 Anti-Slip Self-Sticking Adhesive Value Pack Applied For B-564 1 in. x 250 ft. 1 Roll 81730 Anti-Slip Aluminum-Backed* Applied For B-875 1 in. x 50 ft. 1 Roll 81731 Anti-Slip Aluminum-Backed* Value Pack Applied For B-875 1 in. x 250 ft. 1 Roll 81732 *Apply with a construction-grade adhesive. Photoluminescent Strip Photoluminescent Strip As Close As Practicable 1/ 1/ Stair Markings Platform or Landings Leading Edge Perimeter Demarcation Lines-Floor Mounted 4 Max FINAL Existing Illuminated Exit Sign As May Be Required By Building Code Photoluminescent Strip As Per 2.2.9.3 Door Hardware Marking As Per 2.2.9.2 Door Sign As Per 2.2.9.1 As Close As Practicable As Close As Practicable; 4 Max. Perimeter Demarcation Lines-Wall Mounted Intermediate Exit Doors and Final Exit Doors Hand Rails For more information on NYC Local Law 26 and code requirements for new construction, visit www.bradyid.com/bradyglo. 7

Photoluminescent products backed by 90 years Final Exit Doors leading directly to the exterior are required to be marked as final exit doors. GLOW-IN-THE-DARK SAFETY GUIDANCE SIGNS FINAL 14 in. x 10 in. Material MEA# Brady Material No. 1 Each 10 Per Pack Self-Sticking Adhesive Arrow Down, Left MEA #218-05-M B-523 81719 81720 Self-Sticking Adhesive Arrow Down, Right MEA #218-05-M B-523 81721 81722 Aluminum Arrow Down, Left MEA #233-05-M B-552 81723 81724 Aluminum Arrow Down, Right MEA #233-05-M B-552 81725 81726 Final Exit Sign Exit Through Lobby Intermediate exit doors leading to a street level lobby are required to be marked accordingly. GLOW-IN-THE-DARK SAFETY GUIDANCE SIGNS THROUGH LOBBY 7 in. x 18 in. Material MEA# Brady Material No. 1 Each 10 Per Pack Self-Sticking Adhesive Arrow Down, Left MEA #218-05-M B-523 81826 81827 Self-Sticking Adhesive Arrow Down, Right MEA #218-05-M B-523 81822 81823 Aluminum Arrow Down, Left MEA #233-05-M B-552 81828 81829 Aluminum Arrow Down, Right MEA #233-05-M B-552 81824 81825 Exit through Lobby Sign 8 For more information on BradyGlo photoluminescent products and our 6-year limited warranty, visit www.bradyid.com/bradyglo.

of adhesive experience. Directional and Door Signage Directional and door signs, which include arrows indicating the direction of travel, are required on: Doors opening to exits or exit passageways Doors opening to corridors where such corridors act as required exit passageways connecting two vertical exits Doors serving as horizontal exits Stairwell exits Transfer levels and wherever egress direction is not clear GLOW-IN-THE-DARK SAFETY GUIDANCE SIGNS - w/running MAN 5 in. x 14 in. Material MEA# Brady Material No. 1 Each 10 Per Pack Self-Sticking Adhesive Arrow Right MEA #218-05-M B-523 81806 81807 Self-Sticking Adhesive Arrow Up, Right MEA #218-05-M B-523 81818 81819 Self-Sticking Adhesive Arrow Down, Right MEA #218-05-M B-523 81802 81803 Self-Sticking Adhesive Arrow Left MEA #218-05-M B-523 81794 81795 Self-Sticking Adhesive Arrow Up, Left MEA #218-05-M B-523 81814 81815 Self-Sticking Adhesive Arrow Down, Left MEA #218-05-M B-523 81798 81799 Self-Sticking Adhesive No Arrow Running Man Right MEA #218-05-M B-523 81918 81920 Self-Sticking Adhesive No Arrow Running Man Left MEA #218-05-M B-523 81919 81921 Aluminum Arrow Right MEA #233-05-M B-552 81808 81809 Aluminum Arrow Up, Right MEA #233-05-M B-552 81820 81821 Aluminum Arrow Down, Right MEA #233-05-M B-552 81804 81805 Aluminum Arrow Left MEA #233-05-M B-552 81796 81797 Aluminum Arrow Up, Left MEA #233-05-M B-552 81816 81817 Aluminum Arrow Down, Left MEA #233-05-M B-552 81800 81801 Aluminum No Arrow Running Man Right MEA #233-05-M B-552 81922 81924 Aluminum No Arrow Running Man Left MEA #233-05-M B-552 81923 81925 6 Max 2 2 Marking to Exitways Marking for Unclear Egress Pathways For more information on NYC Local Law 26 and code requirements for new construction, visit www.bradyid.com/bradyglo. 9

Get durability you can count on with a 6-year Not an Exit Not an Exit signs are required to be placed on doors along the egress path that lead to dead ends, such as mechanical rooms and storage closets. GLOW-IN-THE-DARK SAFETY GUIDANCE SIGNS - NOT AN 10 in. x 7 in. Material MEA# Brady Material No. 1 Each 10 Per Pack Self-Sticking Adhesive MEA #218-05-M B-523 81882 81883 Aluminum MEA #233-05-M B-552 81884 81885 NOT AN 4 Max Not An Exit Sign Door Hardware Markers Door hardware of all intermediate and final exit doors requires marking behind, immediately adjacent to, or on the door handle and/or escutcheon. GLOW-IN-THE-DARK DOOR HARDWARE MARKERS Material MEA# Brady Material No. Size Qty./Pack Self-Sticking Adhesive MEA #218-05-M B-523 4.125 in. x 4.125 in. 5 Markers 81853 Existing Illuminated Exit Sign As May Be Required By Building Code FINAL Photoluminescent Strip As Per 2.2.9.3 Door Hardware Marking As Per 2.2.9.2 Door Sign As Per 2.2.9.1 Intermediate Exit Doors and Final Exit Doors 10 For more information on BradyGlo photoluminescent products and our 6-year limited warranty, visit www.bradyid.com/bradyglo.

limited warranty. 10-floor Starter Kit Complete kit contains all the BradyGlo photoluminescent products needed to mark up to 10 stairwells in compliance with NYC Local Law 26. GLOW-IN-THE-DARK 10 FLOOR STARTER KIT Description MEA# Brady Material No. Size Qty./Pack 10 Floor Starter Kit Includes Items Listed Below: 81785 Pre-Cut "L" Shaped Self-Sticking MEA #218-05-M B-523 9 in. x 3 in. 520 Markers Adhesive Stair Markers (260 Right/260 Left) Self-Sticking Adhesive High Intensity Tape MEA #218-05-M B-523 1 in. x 250 ft. 3 Rolls Self-Sticking Adhesive High Intensity Hazard Tape MEA #218-05-M B-523 1 in. x 250 ft. 1 Roll Aluminum Final Exit Sign Arrow Down, Left MEA #233-05-M B-552 14 in. x 10 in. 1 Sign Aluminum Final Exit Sign Arrow Down, Right MEA #233-05-M B-552 14 in. x 10 in. 1 Sign Door Hardware Markers MEA #218-05-M B-523 4.125 in. x 4.125 in. 5 Markers Total Complete Marking Kit for 10 Stairwells For more information on NYC Local Law 26 and code requirements for new construction, visit www.bradyid.com/bradyglo. 11

BradyGlo Professional Services Brady offers a full range of services, including on-site training and supervision services if you use your own personnel for installation. Our consultants work with you to determine your best options for NYC Local Law 26 compliance. All of our services include training on proper maintenance procedures to ensure long product life. Professional Installation Services Brady s turnkey service includes: Complete site survey to determine material requirements Installation of MEA-approved products A trained team of installation professionals Post-installation audit to ensure code compliance Installation Training Brady s how to training of your personnel includes: Instruction on how to comply with NYC Local Law 26, RS 6-1 and 6-1A Proper installation procedures, including surface preparation and finishing techniques Instruction on how to perform a post-installation audit to ensure compliance On-Site Supervision Brady s on-site supervisor will provide: Installation training and supervision of your crew Overview of MEA-approved products required for code compliance Post-installation audit to ensure code compliance Code Compliance Certification After installation, Brady can recommend a New York State-licensed engineer who can perform a third-party controlled installation inspection, gather required documentation, and submit a Certificate of Completion to the Building Department. Annual Maintenance Service This service includes a complete annual inspection of all installed BradyGlo photoluminescent products. We look for any missing, damaged, or loose markings, or products that show wear or are missing MEA labels. We then provide a post-inspection report, including an estimate for material and installation costs. Contact Brady at 1-877-942-7239 to discuss BradyGlo photoluminescent products and service options. Or visit www.bradyid.com/bradyglo. Brady Corporation 6555 W. Good Hope Road Milwaukee, WI 53201-2131 2005 Brady Corporation NYC Local Law 26 RS 6-1 and 6-1A Catalog 2005-2006