Instructions for installation Everlux Egress Path Marking System

Similar documents
2009 IBC Section 1024 Approved Luminous Egress Path Markings

Compliance. Safety. Durability.

Luminous Egress Path Markings

IBC/IFC Egress Path Marking System Compliance Manual

SPECIFICATIONS Aluminum Stair Nosing - Bull Nosing

2009 IBC/IFC Photoluminescent Signs & Pathway Marking Systems Frequently Asked Questions

When the Lights go out Ours come ON

New York City RS 6.1 Photoluminescent Exit Path Markings

UL 1994 Listed Code Compliant Photoluminescent Egress Path Markings per IBC & IFC

Compliance Guide for Fire Code

CONSTRUCTION TECHNOLOGY UPDATE

The easiest way to comply with local law 26. A Review of New York City Building Code Reference Standard RS 6-1

T1. Steps and stairs general

A field perspective-what the inspector looks for during a Racking inspection.

Date of Authorization September 30, 2004 BMEC Authorization # BMEC Application A

BRADYGLO EMERGENCY EGRESS MARKING HANDBOOK

Appendix B To the Overview of Church-Based Volunteer Host Sites

STEP UP TO SAFETY. Course #: NYS05B 1 AIA HSW CE Hour

REFERENCE STANDARD RS-6 MEANS OF EGRESS

DIVISION 10 SPECIALTIES

Technical Justification for

STOCK CATALOGUE US VERSION

MAIN CATALOG Photoluminescent Safety Products and Bumper Guards

Powered by glowzone TM. Dependable lighting for safe egress. Safe egress when emergency electrical lighting and signage fail.

CITY OF DANA POINT SITE ACCESSIBILITY AND PARKING B103 SITE INTRODUCTION

Design Aid for Barrier-Free Accessibility in Existing Buildings

PRODUCTS. USLED - Safety Products - Marker & Delineators GLOW STEP. Reduce slips and falls with recycled light

Specification for Ecoglo Photoluminescent & Non Slip Nosing to meet BCA Code on Accessibility in Built Enviornment

2006 International Building Code Modified for the 2007 Florida Building Code 6/5/06

PROMULGATION OF THE NEW YORK CITY BUILDING CODE REFERENCE STANDARD RS 6-1 AND RS 6-1A IN RELATION TO PHOTOLUMINESCENT EXIT PATH MARKINGS

PROMULGATION OF THE NEW YORK CITY BUILDING CODE REFERENCE STANDARD RS 6-1 AND RS 6-1A IN RELATION TO PHOTOLUMINESCENT EXIT PATH MARKINGS

PROMULGATION OF THE NEW YORK CITY BUILDING CODE REFERENCE STANDARD RS 6-1 AND RS 6-1A IN RELATION TO PHOTOLUMINESCENT EXIT PATH MARKINGS

MAIN CATALOG Photoluminescent Safety Products and Bumper Guards

ICC CODE CORNER 2012 IFC Code & Commentary

THE JALITE 7010 EXIT SIGN SYSTEM LIT effective, efficient and elegant, exit identification solutions designed to save lives.

SITE ACCESSIBILITY AND PARKING

SENSE Level I Welding Process Certification Test Module 3: Drawing and Welding Symbol Interpretation

(Note: This document is the same as been forwarded to be published in the City Record for public hearing and comment)

SUPPLEMENTAL ACCESSIBILITY NO. 5 PLAN REVIEW CHECKLIST

Tate Access Floors, Inc. WC5000 Air Seal Access Floor Panel Cornerlock Understructure

a. Plaques with fixed panel. B. Related Sections: The following sections contain requirements that relate to this section:

PSA / PSPA Guide to the Use of Photoluminescent Safety Markings. Part One: Egress Markings In Stairwells

VENUE AND SAFETY INFORMATION FOR SCHOOL EXCURSION

Your 3 Step Guide to selecting the correct stair nosing

Plan Check No. A. ELEVATORS

mediatek mediatek Library and archive shelving systems Taking shelving to the next level BC004.03

General Requirements for Access

Life Safety Training

Plot Plan for Decks Date. Name Phone # Address Zip APN # _- _- _ (see property tax bill or call the assessor s office ) FRONT PROPERTY LINE

EGRESS AZMIR SULTANA NICOLAS MIMU SAKUMA EDWIN VEGA CHAMORRO

MIGUTAN. Installation instructions. MIGUTAN-Systems with short AAS sheets

RISK BULLETIN. Walking & Work Surfaces: Floors, Stairs and Elevated Workstations Checklist DATE / / NAME SIGNATURE WALKWAYS YES NO ACTION ASSIGNED

Direct Service Done Right. Stair Treads + Nosings Catalog

Elevators and Lifts

Caparol System PRO Data sheet

PRODUCTS AND SYSTEMS FOR ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

GLO BRITE FRAMED SIGNS

The Catholic University of America Cardinal Station Washington, DC INTERIOR SIGNAGE GUIDELINES. January 21, 2009 (Revised)

QC Inspection and Qualification Procedure- TX-EDU-VT-1-07, Revision # by Richard J DePue, Supersedes IW-VT-1 Visual Inspection Procedure

Site Accessibility Survey & Transition Plan

Sorrento Stone Surrounds

Tunnel Signage. Section B Tunnel Signage. Tunnel Signage Introduction B.1.1

Niklas portable freestand

Pittsburgh Corning Glass Block Shower System Mortar Installation Standard Fit Shower Instructions

FLOOR MARKING GUIDE. Regulations, color standards, tips, solutions and more!

Student Services & Classroom Addition

Conergy SolarFamulus II

-=== Building Safety Departnlent 'Neil Avenue, Room 202 Cheyenne, WY Phone: (307) Fax: (307) RAMPS

VISIBLY BETTER. Photoluminescent Emergency Path Marking Solutions for Indoor and Outdoor Use. IFC/IBC, NYC LL and NFPA Compliant Guidance Systems

Glasboard Liners. installation details. Installation Guide for Glasbord Fibreglass Reinforced Plastic (FRP) panels

Fosroc Nitoproof 800 Method Statement

2020 DISPLAY REGULATIONS

Stairs have many potential violations this Newsletter is Part 1 of two parts.

SPARTANBURG COUNTY BUILDING CODES DEPARTMENT

SPECIFICATION FOR CI DECKING SYSTEM

2015 International Fire Code

BENTLEY ELEMENTS COLLECTION LVT

m2 Anti-Slip Tape Daylight Fluorescent R13

SOMNIUM SIGNS PROMOTING YOUR BUSINESS

Robbie Davis, Chairman 5998 Dortches Boulevard Rocky Mount, NC 27804

THE DDA SHOP STAIR NOSING RANGE

Trans-Edge. Heavy-Duty Stair & Floor System suitable for heavy traffic exterior & interior environments

High Visibility Anti Slip Tread Systems

From the ADA and ABA Accessibility Guidelines for Buildings and Facilities

Hazards Outside The Laboratory: Loading Dock Safety

Supplier and Installer of Heavy Duty Stair Treads, Nosings and Guidance Path Strips

Accessible Means Of Egress

Outer Skin Kit & Flue: IB600, IB850, IB1100 Installation Manual

Installation & Maintenance Guide

1. Refer to SECTION SIGNS and reolace entire document with aftached new soecification. 5. Refer to Electrical Drawing E3.1

SECTION 716 SIGN MATERIALS SCOPE

Structural Calculations for standard BALCONY 1 system handrail using 55mm diameter posts (48.3mm x 5mm CHS) & 150 x 150 x 15mm base plates

Double Tidy Rail. Assembly Instructions- Please keep for future reference. Important - Please read these instructions fully before starting assembly

SECTION GYPSUM BOARD

The insulating panel for energy conscious interior renovation. The product. Safe, noticeably better Proved a million times.

Just Makes Cents... Per Watt. Compliance Report Composition L-Foot Kit State of California September 25th SOLARACK INC.

SECTION RESILIENT SHEET FLOORING

(Statute, Rule, FBC, Industry) FBC 406.3, see also FBC No provisions in FBC or FS

JC Code & Construction Consultants, Inc. Advanced 2010 FBC Update Ch. 1 to 16

Transcription:

UL Listed Luminous Egress Path Marking Systems CAUTION SAVE THESE INSTRUCTIONS The includes the following components: Photoluminescent Egress Path marking for wall installation Photoluminescent Egress Path marking for floor installation Emergency exit symbols, directional signage and exit signs where is required or appropriate Installation The mounting height of floor proximity path markers and floor identification signs are to be in accordance with local and national codes but is not to exceed 18 inches (45.7 cm) above finished floor height. The maximum spacing between luminous segments is not to exceed inches ( cm). The number in the blank shall be no more than 12 inches (30.5 cm) per inch of horizontal luminous length, or 44 inches (110 cm), whichever is less. The spacing between the corner of a change in direction of the path of egress and the luminous segment is not to exceed 4 inches (10.2 cm). Directional indicators (arrows or the like) are to be mounted at changes in direction and at locations intended to lead persons out of, or from entering a dead-end corridor. Minimum amount and type of ambient illumination Before installation it must be determined that there is a minimum of 1 foot-candles of fluorescent light, with a minimum colour of temperature of 4000 ºK, on the Path Marking System face at all times during building occupancy. The control of the ambient illumination shall be restricted to authorized personnel. Where the illumination level is less than the minimum specified value, the system shall not be used. V1 Edition: 21-02-18 Page 1 of 5

Mounting instructions Path marking for wall installation Mark the height at which the strip is to be fitted Apply the strip to the wall surface using the height markings as a guide. A wallpaper edging roller can help with this process as it applies even pressure across the sign surface and helps to ensure that the adhesive is displaced and well dispersed The path marking strips for wall installation can be installed with tamperproof aluminium rails: The aluminium rail must be screwed to the wall at multiple points along its length. V1 Edition: 21-02-18 Page 2 of 5

Path marking for floor, L s for step marking and Path and obstacle marking rolls: Prepare the receiving surface by removing dust and grease with a suitable cleaning agent Mark the location of application on the floor or stair surface Remove the backing material Apply the product to the pre-prepared floor or stair surface Ensure proper adhesion by applying pressure all over the surface area. A wallpaper edging roller can help with this process as it applies even pressure across the whole surface. V1 Edition: 21-02-18 Page 3 of 5

Stairnosing The extruded aluminium profile is designed to protect the edges of stairs & steps Manufactured with grooves that offer anti-slip protection that is effective in wet conditions. Present the interior angle of the aluminium profile along the length of the stair edge at points A & B (as shown in the figure below). Once positioned, roll the profile back towards the rear of the stair and apply direct pressure along the edges of both profile surfaces to ensure adhesion. If the stair material is rough or porous it may be advisable to consider installation using rawl-plugs and screws. Aluminium strips for application on Uneven Floors Everlux photoluminescent aluminium profile floor strips have been developed to be applied to irregular floor surfaces. They offer anti-slip characteristics, even in oil spill situations, due to the inclusion of slots throughout all their extension. ensure that the surface where the ground profile will be applied is clean and free from dust and grease. Apply pressure along the entire length of the floor strip to ensure complete adhesion V1 Edition: 21-02-18 Page 4 of 5

If the floor surface is rough or porous it may be advisable to consider installation using rawl-plugs and screws. The aluminium floor strips can be supplied with pre-drilled holes if specified when ordering. Maintenance Clean the surface of the sign periodically using a wet cloth. Cleaning operation The products do not require any particular attention and can be cleaned using either with a dry or damp clean cloth. Do not use detergent products. V1 Edition: 21-02-18 Page 5 of 5