UNITED NATIONS / DOT PERFORMANCE CERTIFICATION 4G DESIGN QUALIFICATION

Similar documents
UNITED NATIONS / DOT PERFORMANCE CERTIFICATION 4G DESIGN QUALIFICATION

UNITED NATIONS / DOT PERFORMANCE CERTIFICATION 4G DESIGN QUALIFICATION

UNITED NATIONS / DOT PERFORMANCE CERTIFICATION 4G DESIGN QUALIFICATION

UNITED NATIONS / DOT PERFORMANCE CERTIFICATION 4G DESIGN QUALIFICATION. 6 x 2.6 Liter Plastic Bottle Packaging with Two Case Sealing Mechanisms

UNITED NATIONS / DOT PERFORMANCE CERTIFICATION 4G PERIODIC RETEST

TESTING. Ontario, CA 91764

UNITED NATIONS / DOT PERFORMANCE CERTIFICATION 4G DESIGN QUALIFICATION

UNITED NATIONS / DOT PERFORMANCE CERTIFICATION 4G DESIGN QUALIFICATION

UNITED NATIONS / DOT PERFORMANCE CERTIFICATION 4G DESIGN QUALIFICATION. 4 X 9 Pint Round Plastic Bottle with Neck Finish & Vented Cap Packaging

UNITED NATIONS / DOT PERFORMANCE CERTIFICATION 4G DESIGN QUALIFICATION. 6 x 2.5 Liter Plastic Bottle Variable Packaging TEST REPORT #:

UNITED NATIONS / DOT PERFORMANCE CERTIFICATION 4G PERIODIC RETEST

UNITED NATIONS / DOT PERFORMANCE CERTIFICATION 4G PERIODIC RETEST

UNITED NATIONS / DOT PERFORMANCE CERTIFICATION 4G PERIODIC RETEST

UNITED NATIONS / DOT PERFORMANCE CERTIFICATION 4G DESIGN QUALIFICATION

UNITED NATIONS / DOT PERFORMANCE CERTIFICATION 4G DESIGN QUALIFICATION. HWS324-4 x 32 Oz. Wide Mouth Glass Jar Packaging TEST REPORT #: 18-MN20004

Testing, LLC. Reference: Gebauer, 4x4 ounce Glass Bottles Ethyl Chloride UN1037. Number per Package: Four (2x2 arrangement)

4G/Y37.5/S/** USA/+CO1382

ANAMA Package & Container Testing Services, Inc.

(4) Production inspection is the inspection that must initially be conducted on each newly manufactured IBC.

ANAMA Package & Container Testing Services, Inc. DEPARTMENT OF TRANSPORTATION PERFORMANCE ORIENTED PACKAGE TESTING CERTIFICATION

OVERVIEW OF PROCEDURE 2A

General requirements.

Staff Contact: Erin N. Topper Telephone (703)

The entire document shall be read and understood before proceeding with a test. ISTA 3B Page 1 of 35

OVERVIEW OF PROCEDURE 2B

ANAMA Package & Container Testing Services, Inc.

The entire document shall be read and understood before proceeding with a test.

e-commerce Fulfillment for Parcel Delivery Shipment

The entire document shall be read and understood before proceeding with a test.

KSS GLOBAL STANDARD. Global Supplier Packaging Guidelines

APPROVAL CA (EIGHTH REVISION) ISSUED BY THE COMPETENT AUTHORITY OF THE UNITED STATES EXPIRATION DATE: NOVEMBER 30, 2016

MK 25 MARINE LOCATION MARKER BY: BILLIE LANOSTROM. Performing Activity: Navel Weapons Support Center Crane Crane. Indiana MARCH 1991 FINAL

[Amdt , 60 FR 50336, Sept. 28, 1995; 60 FR 54409, Oct. 23, 1995, as amended at 69 FR 3696, Jan. 26, 2004; 70 FR 56099, Sept.

DTIC I(IELECTE AM. 111 i EIii N. UI ll AD-A38 015ODODPOPHM/USA/OOD/NAOTR AD-A

III~!11111 i11ifl 1OMB No

DOSSIER: IBC s for the transport of dangerous goods

Testing Packaged Products Weighing More Than 150 Lbs.

ANAMA Package & Container Testing Services, Inc.

Requirements for the construction and testing of packagings for class 6.2 infectious substances of category A

Standard Test Method for Determining Compressive Resistance of Shipping Containers, Components, and Unit Loads 1

Packaging Computer Shipments

BY: BILLIE BUHR. Perforning Activity: Naval Weapons Support Center Crane JANUARY 1992 FINAL

10/92 POP Test (09/92)

Mirror Packaging Supplement

DANGEROUS GOODS PANEL (DGP) MEETING OF THE WORKING GROUP OF THE WHOLE

WIREBOUNO BOX FOR SMAW ROCKETS MECHANICAL ENGINEER. PerfornIng Activity: Crone Division Naval Surface Warfare Center Crane, Indiana

Author: Kerry J. Libbert Mechanical Engineer. Performing Activity: Naval Surface Warfare Center Code 4045 Crane, Indiana

COMMERCIAL ITEM DESCRIPTION CONTAINER, THERMAL, SHIPPING, FOR MEDICAL MATERIEL REQUIRING CONTROLLED TEMPERATURE RANGES

PERFORMANCE ORIENTED PACKAGING TESTING OF JATO IGNITER WOOD BOX FOR PACKING GROUP II SOLID HAZARDOUS MATERIALS

Pointers on Packaging for Computer Shipments

Packaging Perishable Shipments

Testing Packaged Products Weighing up to 150 Lbs.

VPA 8 Status: October 2014 Test Certificates. Containers made of plastic with bung hole or removable lid 4. Fibre drums 5

I I I3. Ml9A1 Container. ".AForm. Approved 9 C TATION PAGE OMB No ~ IT- Exp. Date Jun 30, Unclassitieu None

PMG LISTING CRITERIA FOR STRUCTURAL ADHESIVE JOINING SYSTEMS FOR FITTINGS PREFACE

PDMPak Bottle System for Pressurized Applications

Architectural Wall Products Guide Specifications

DTIC. IIlltllllllll~ll~ll AD-A ELECTE. DODPOPHM/USA/DOD/NADTR92034 REVISION A Superseding DODPOPHM1USA/DOD/NADTR92034 February 1993

Evaluation of HDPE (High Density. Drainage Pipe Manufacturers. Polyethylene) Thermoplastic. NTPEP Committee Work Plan for

Standard Test Method for Determining Compressive Resistance of Shipping Containers, Components, and Unit Loads 1

2. Pallets 2.1 Pallet size x 1000 mm (Preferred size), One Way Pallet, Heat treatment according to ISPM 15

Standard Test Methods for Transmitted Shock Characteristics of Foam-in-Place Cushioning Materials 1

Packaging Perishable Shipments

Compression test of fiberboard shipping containers

TEST REPORT FORM Procedure used: 3A - STANDARD 3A - SMALL 3A - FLAT 3A - LONG VERSION DATE: 2008

Pre-Audit Application Form

CCSB Contact: Larissa A. Franklin Telephone (703) Item Description Class

Architectural Roof and Wall Products Guide Specifications

Chapter 6.5 Requirements for the construction and testing of intermediate bulk containers

DTIC. q/ 7/0 /9- AD-A Y19 1 FINAL. DODPOPHM/USA/DOD/NADTRg1110 ELECTF SHIPPING AND STORAGE CONTAINER

2. Pallets 2.1 Pallet size x 1000 mm (Preferred size), One Way Pallet, Heat treatment according to ISPM 15

Double Coated Urethane Foam Tapes

MSDS Material Safety Data Sheet Lithium-Ion Battery For ClipGrip Personal Fan (clipg201)

Related Rules This Advisory Circular relates specifically to Civil Aviation Rule Part 92, Rule

Pointers on Shipping: Clinical Samples, Biological Substance Category B and Environmental Test Samples

This document is an OVERVIEW ONLY

liii 11 ~111ll1111~ Form Approved Y ISMCAR-AEP

I OMB No /93 POP Test (04/93)

Evaluation of Polypropylene Drainage Pipe Manufacturers

Eliminating Leaking Containers

Dossier: What s the difference between P 650 (ADR) and PI 650 (IATA)?

HP COMPRESSION TEST METHOD A Rev. A

JPAEForm Approv -ed I. PAGOMB No ustimated to average 1 hour per response, including the timne for reviewing instruction

rar-aep IExp Date Jun IForm Approved None N/A Packaging Division, AED LMAR-AEP None Engineering Center Picatinny Arsenal, NJ None -

ARPRO Expanded Polypropylene (EPP) Foam Manhole Grade Adjustment Ring

ISTA 3A PACKAGE PERFORMANCE TEST

None. None PROGRAM IPROJECT ITASK I WORK UNIT

Draft proposals for Test methods for close-coupled solar water heating systems - Reliability and safety

SPCR 059. RISE Research Institutes of Sweden AB Certification SPCR

NOWPak Bottle System, NOWPak Canister System, and Replacement Liner

Packaging & Shipping Laboratory Specimens Guide. Volume 14

New Pressure Sensitive Device to Measure and Predict Package Drops

CONDUCTED: Page 1 of 6

Architectural Roof and Wall Products Guide Specifications

Fred Simmons CHANGE CONTROL SHEET

Test Report No. SDHL PK Date: Sep.02, 2016 Page 1 of 15

East Building, PHH-30 U.S. Department New Jersey Avenue S.E. of Transportation Washington, D.C DOT-SP 16279

NOWPak Bottle System. Liner-based bottle system with a pre-cleaned, two-ply, heat-sealed PTFE T420 liner APPLICATIONS FEATURES & BENEFITS

The entire document shall be read and understood before proceeding with a test.

3M Scotchmate Reclosable Fasteners

Transcription:

UNITED NATIONS / DOT PERFORMANCE CERTIFICATION 4G DESIGN QUALIFICATION 4 x 1 Gallon Round 150 Gram Plastic Bottle with 38-439 Neck Finish and Two Case Sealing Mechanisms: #1) Taped Top and Bottom Flaps #2) Taped Top and Glued Bottom Flaps TEST REPORT #: 09-7088(REV 1) u n 4G / Y25.8 / S / ** USA / +CC6016 ** Insert year the packaging is manufactured TESTING PERFORMED FOR: PUREPAK TECHNOLOGY CORPORATIONS 324 South Braken Lane Suite 3 Chandler, AZ 85224 ATTN: Mike Dodd TESTING PERFORMED BY: TEN-E Packaging Services, Inc. TEN-E Packaging Services, Inc. 1666 County Road 74 326 N. Corona Avenue Newport, MN 55055 Ontario, CA 91764 Phone: (651) 459-0671 Phone: (909) 937-1260 Fax: (651) 459-1430 Fax: (909) 937-1262

Page 2 of 18 TABLE OF CONTENTS Section I: CERTIFICATION... 3 Sections II & V: PACKAGING DESCRIPTION / COMPONENT DRAWINGS... 4 Section III: TEST PROCEDURES AND RESULTS... 8 DROP TESTS Taped Top and Bottom Flaps... 8 DROP TESTS Taped Top and Glued Bottom Flaps... 9 STACKING & STACKING STABILITY TESTS Taped Top and Bottom Flaps... 10 STACKING TESTS Taped Top and Glued Bottom Flaps... 11 PRESSURE DIFFERENTIAL TEST... 12 REPETITIVE SHOCK VIBRATION TESTS Taped Top and Bottom Flaps... 13 REPETITIVE SHOCK VIBRATION TESTS Taped Top and Glued Bottom Flaps... 14 COBB WATER ABSORPTION TESTS... 15 REGULATORY AND INDUSTRY STANDARD REFERENCES... 16 Section IV: MATHEMATICAL CALCULATIONS... 17 NOTES AND COMMENTS Note for Rev 1: Report 09-7088 issued on May 27, 2009 has been updated as of May 27, 2009. Overall height quality control audit information of the bottle on page 6 has been updated per client s request under this revision

Page 3 of 18 SECTION I: CERTIFICATION Design Qualification of the PurePak Technology Corporation 4 x 1 Gallon Round 150 Gram Plastic Bottle with 38-439 Neck Finish and Two Case Sealing Mechanisms: #1) Taped Top and Bottom Flaps #2) Taped Top and Glued Bottom Flaps TEN-E PACKAGING SERVICES, INC. certifies that the PurePak Technology Corporation packaging referenced above has passed the standards of the DEPARTMENT OF TRANSPORTATION S TITLE 49 CFR; Performance Oriented Packaging Standards, Section 178. This package is also certified under IMDG, ICAO/IATA Regulations and the UN Recommendations on the Transport of Dangerous Goods. It is the responsibility of the end user to determine authorization for use under these regulations. The use of other packaging methods or components other than those documented in this report may render this certification invalid. SUMMARY OF PERFORMANCE TESTS UN /DOT TEST CFR REFERENCE TEST LEVEL TEST CONTENTS TEST COMPLETED TEST RESULTS Drop #1 178.603 1.6m Methanol /Water May 1, 2009 PASS Drop #2 178.603 1.6m Methanol /Water May 1, 2009 PASS Stacking #1 178.606 635.0 Kg 24 Hrs. Water May 1, 2009 PASS Stacking #2 178.606 249.4 Kg 24 Hrs. Water April 30, 2009 PASS Pressure 173.27 100kPa 30 Min. Water May 7, 2009 PASS Vibration #1 178.608 3.6 Hz 1 Hr. Water April 30, 2009 PASS Vibration #2 178.608 3.6 Hz 1 Hr. Water May 1, 2009 PASS Cobb 178.516 30 minutes --- May 1, 2009 PASS TEST REPORT NUMBERS: 09-7088 UN MARKING: (CFR 49-178.503) u n 4G / Y25.8 / S / ** USA / +CC6016 PACKAGING IDENTIFICATION CODE: 4G - Fiberboard Box (178.516) PERFORMANCE STANDARD: AUTHORIZED GROSS MASS: "S" DESIGNATION: YEAR OF MANUFACTURE: STATE AUTHORIZING THE MARK: PACKAGING CERTIFICATION AGENCY: THIRD PARTY PACKAGE IDENTIFICATION: Y (Packaging meets Packing Group II and III tests) 25.8 Kg (56.8 Lbs.) Denotes Inner Packagings **Insert year the packaging is manufactured USA (+CC) TEN-E Packaging Services, Inc. (Ontario, CA) +CC6016 PERIODIC RETEST DATE: May 7, 2011 ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING ANY WARRANTY THAT THE PACKAGING TESTED IS MERCHANTABLE OR FIT FOR A PARTICULAR PURPOSE, ARE DISCLAIMED. In no event shall TEN-E Packaging Services, Inc. liability exceed the total amount paid by PurePak Technology Corporation for services rendered. In the event of future changes to the above referenced test standard, it is the responsibility of PurePak Technology Corporation to determine whether additional testing or updating of past testing is necessary to verify that the packaging we have tested remains in compliance with those standards. MANUFACTURER: PurePak Technology Corporation 324 South Braken Lane Suite 3 Chandler, AZ 85224

Page 4 of 18 SECTIONS II & V: PACKAGING DESCRIPTION / COMPONENT DRAWINGS 4 x 1 Gallon Round 150 Gram Plastic Bottle with 38-439 Neck Finish and Taped Top and Bottom Flaps ASSEMBLY DRAWING TEST LEVELS Certification Type: Packaging Code Designation: Packing Group: Design Qualification 4G Specific Gravity: 1.6 Internal Pressure: 100 kpa TEST SAMPLE PREPARATION (Refer to Section IV) Overall Packaging Tare Weight: II 1,558 Grams Inner Packaging Fill Capacity (98% Maximum Capacity): Methanol/Water 3,679 Grams Water 3,793 Grams Package Test Weight: Methanol/Water 16.2 Kg (35.7 Lbs.) Water 16.7 Kg (36.8 Lbs.) Authorized Package Gross Mass: 25.8 Kg (56.8 Lbs.) CLOSING METHODS INNER PACKAGING Application Torque 45 In-Lbs. Equipment: Kaps All Electronic Torque Tester #701 CLOSING METHODS SHIPPER Top Flaps: Type: Width: 48 mm (2") Overlap: Tape Pattern: Inner Flaps: Outer Flaps: Type: 3M #375 Pressure Sensitive Tape 2" Minimum Center Seam Meet Meet Bottom Flaps: Width: 48 mm (2") Overlap: Tape Pattern: Inner Flaps: Outer Flaps: 3M #375 Pressure Sensitive Tape 2" Minimum Center Seam Meet Meet

Page 5 of 18 4 x 1 Gallon Round 150 Gram Plastic Bottle with 38-439 Neck Finish and Taped Top and Glued Bottom Flaps ASSEMBLY DRAWING TEST LEVELS Certification Type: Packaging Code Designation: Packing Group: Design Qualification 4G Specific Gravity: 1.6 Internal Pressure: 100 kpa TEST SAMPLE PREPARATION (Refer to Section IV) Overall Packaging Tare Weight: II 1,558 Grams Inner Packaging Fill Capacity (98% Maximum Capacity): Methanol/Water 3,679 Grams Water 3,793 Grams Package Test Weight: Methanol/Water 16.2 Kg (35.7 Lbs.) Water 16.7 Kg (36.8 Lbs.) Authorized Package Gross Mass: 25.8 Kg (56.8 Lbs.) CLOSING METHODS INNER PACKAGING Application Torque 45 In-Lbs Equipment: Kaps All Electronic Tester #701 CLOSING METHODS SHIPPER Top Flaps: Type: Width: 48 mm (2") Overlap: Tape Pattern: Inner Flaps: Outer Flaps: Type: Inner Flaps: Outer Flaps: 3M #375 Pressure Sensitive Tape 2" Minimum Center Seam Meet Meet Bottom Flaps: Hot Glued; Customer Provided Meet Meet

Page 6 of 18 CLOSURE Manufacturer: Rexam Plastic Packaging (QIM-317-4937) Component Specification Information Information Description: 38-439 Standard Closure Quality Control Audit Material/Pigment: Polypropylene / White Polypropylene / White Density: 0.904 g/cc Tare Weight: 10.3 Grams 10.36 Grams Overall Dimensions: Height 1.016 ± 0.015 1.011 Diameter 1.701 ± 0.015 1.694 Thread: Type Style Finish Dimensions: T 1.483 ± 0.007 1.495 E 1.389 ± 0.007 1.381 Thread Pitch Markings (QC Audit): 134 LINER/GASKET Component Specification Information Information Description: Polyethylene Foam Liner Tare Weight: Thickness: 0.052 Diameter: 1.374 PLASTIC BOTTLE Manufacturer: Setco: Anaheim, CA (D08-043) Component Specification Quality Control Audit 0.65 Grams Quality Control Audit Information Information Description: 1 Gallon Round Plastic Bottle Material/Pigment: High Density Polyethylene / High Density Polyethylene / Natural Natural Method of Mfgr: Blow Molded Density: 0.941 g/cc Melt Index (190/21.6): 19.52 g/10 minutes Tare Weight: 150 Grams ± 6 Grams 150 Grams Capacity: Rated 1 Gallon Overflow 3908 cc ± 44 3,870 Grams (1.022 Gallons) Overall Dimensions: Diameter 6.002 ± 0.080 5.970 Height 12.390 ± 0.090 12-9/16 Finish Dimensions: T 1.460 ± 0.015 1.473 E 1.367 ± 0.015 1.378 Thread Pitch 0.1651 Wall Thickness: Nominal Minimum 0.016 Markings (QC Audit): 80612 Z SPI 2 HDPE Recycling Symbol Drawing

Page 7 of 18 SHIPPER Manufacturer: Sound Packaging: Chandler, AZ Component Information Specification Information Quality Control Audit Description: Regular Slotted Container Material/Flute (Inner to Outer): Double Wall Mottled White Corrugated Fiberboard; B/C-Flute Basis Weight (Outer to Inner) Lbs./MSF: 42.1/26.2/42.7/25.3/41.9 Combined Wt. of Facings: 126.7 Tare Weight: 825 Grams Overall Dimensions Inside Outside Length 12-1/2 13 Width 12-1/2 12-3/4 Height 12-1/2 13-7/8 Board Caliper (Nominal): 0.262 Manufacturer s Joint: Inside Glued, 1-3/8 Lap Markings (QC Audit): 12 1/4 x 12 1/4 x 12 1/2 Sound Packaging, LLC BOX CERTIFICATE Drawing Component Information Quality Control Audit (A) Corrugated Manufacturer: Sound Packaging (B) Structure: (C) Bursting Test (D) Min comb Wt Facings: Double Wall 275 Lbs. Per Sq Inch 110 Lbs. Per M Sq Ft (E) Size Limit: 95 (F) Gross Wt Lt: (G) Location: 100 Lbs. Chandler, AZ

Page 8 of 18 SECTION III: TEST PROCEDURES AND RESULTS DROP TESTS Taped Top and Bottom Flaps TEST CONTENTS: TEST INFORMATION Methanol/Water Solution (0.97 SG) SAMPLE PREPARATION: Refer to Section II CONDITIONING: -18 C (0 F), Chamber #201 TEST CONTENTS TEMP.: -18 C (-0.76 F) DROP HEIGHT: 1.6 Meters (63 ) (Refer to Section IV) TEST EQUIPMENT: L.A.B. Accu Drop 160 #301 CRITERIA FOR PASSING THE TEST For packaging containing liquid, each packaging does not leak. There can be no damage to the outer packaging likely to adversely affect safety during transport and there is no leakage of the filling substance from the inner packaging. Any discharge from a closure is slight and ceases immediately after impact with no further leakage. ( 178.603) DROP ORIENTATIONS & TEST RESULTS Sample #1: Flat on Bottom Sample #2: Flat on Top Sample #3: Flat on Long Side PASS: No leakage or damage. PASS: No leakage. Slight deformation to bottles on impact. PASS: No leakage or damage. Sample #4: Flat on Short Side Sample #5: Bottom Corner *Sample #1: Top Corner PASS: No leakage or damage. PASS: No leakage. Slight deformation to shipper on impact. PASS: No leakage. Slight deformation to shipper on impact. *Sample used for Flat on Bottom Drop is also used for the Top Corner Drop

Page 9 of 18 DROP TESTS Taped Top and Glued Bottom Flaps TEST CONTENTS: TEST INFORMATION Methanol/Water Solution (0.97 SG) SAMPLE PREPARATION: Refer to Section II CONDITIONING: -18 C (0 F), Chamber #201 TEST CONTENTS TEMP.: -18 C (-0.76 F) DROP HEIGHT: 1.6 Meters (63 ) (Refer to Section IV) TEST EQUIPMENT: L.A.B. Accu Drop 160 #301 CRITERIA FOR PASSING THE TEST For packaging containing liquid, each packaging does not leak. There can be no damage to the outer packaging likely to adversely affect safety during transport and there is no leakage of the filling substance from the inner packaging. Any discharge from a closure is slight and ceases immediately after impact with no further leakage. ( 178.603) DROP ORIENTATIONS & TEST RESULTS Sample #6: Flat on Bottom Sample #7: Flat on Top Sample #8: Flat on Long Side PASS: No leakage or damage. PASS: No leakage. Slight deformation to bottles on impact. PASS: No leakage or damage. Sample #9: Flat on Short Side Sample #10: Bottom Corner *Sample #6: Top Corner PASS: No leakage or damage. PASS: No leakage. Slight deformation to shipper on impact.. PASS: No leakage. Slight deformation to shipper on impact. *Sample used for Flat on Bottom Drop is also used for the Top Corner Drop

Page 10 of 18 STACKING & STACKING STABILITY TESTS TEST CONTENTS: TEST INFORMATION Water SAMPLE PREPARATION: Refer to Section II CONDITIONING: 73 F / 50% RH, Chamber #202 TEST LOAD APPLIED: TEST DURATION: 635.0 Kg (1,400.0 Lbs.) (Refer to Section IV) 24 Hours TEST EQUIPMENT: L.A.B. 5250 Compression System #402 Taped Top and Bottom Flaps CRITERIA FOR PASSING THE TEST There must be no leakage of the filling substance from the inner receptacle, or inner packaging. There can be no deterioration that could adversely affect transport safety or any distortion liable to reduce the package s strength, cause instability in stacks of packages, or cause damage to inner packagings that is likely to reduce safety in transport. ( 178.606) STACKING TEST SET UP AND RESULTS Sample # Maximum Deflection After 24 Hours Results 11 1/16 PASS 12 1/16 PASS 13 1/16 PASS STACKING STABILITY TEST SET-UP CRITERIA FOR PASSING THE TEST In guided load tests, stacking stability must be assessed after test completion. Two filled packagings of the same type must be placed on the test sample. The stacked packages must maintain their position for one hour. ( 178.606) PASS

Page 11 of 18 STACKING TESTS Taped Top and Glued Bottom Flaps TEST CONTENTS: TEST INFORMATION Water SAMPLE PREPARATION: Refer to Section II CONDITIONING: 73 F / 50% RH, Chamber #202 TEST LOAD APPLIED: TEST DURATION: TEST EQUIPMENT: 249.4 Kg (550 Lbs.) (Refer to Section IV) 24 Hours Dead Load Weights CRITERIA FOR PASSING THE TEST There must be no leakage of the filling substance from the inner receptacle, or inner packaging. There can be no deterioration that could adversely affect transport safety or any distortion liable to reduce the package s strength, cause instability in stacks of packages, or cause damage to inner packagings that is likely to reduce safety in transport. ( 178.606) STACKING TEST SET-UP AND RESULTS Sample # Maximum Deflection After 24 Hours Results 14 0 PASS 15 0 PASS 16 0 PASS Stacking Stability: Not conducted; required only for guided load tests.

Page 12 of 18 PRESSURE DIFFERENTIAL TEST TEST CONTENTS: FILL CAPACITY: CLOSURE APPLICATION: CONDITIONING: TEST PRESSURE: TEST DURATION: TEST INFORMATION Water Maximum Capacity Refer to Section II Ambient 100kPa 30 Minutes AREA OF PRESSURIZATION: Through the Bottom TEST EQUIPMENT: Regulated Water Source Gauge #602 CRITERIA FOR PASSING THE TEST Packaging for which retention of liquid is a basic function must be capable of withstanding the pressure requirements without leakage. ( 173.27) HYDROSTATIC PRESSURE TEST SET-UP & RESULTS Sample # Results Comments / Observations 1 PASS 2 PASS All three samples maintained the 100kPa test pressure for 30 minutes without leakage. 3 PASS

Page 13 of 18 REPETITIVE SHOCK VIBRATION TESTS TEST CONTENTS: TEST INFORMATION Water SAMPLE PREPARATION: Refer to Section II CONDITIONING: 73 F / 50% RH, Chamber #202 TABLE DISPLACEMENT: 1 TEST FREQUENCY: TEST DURATION: TEST EQUIPMENT: 3.6 Hz 1 Hour Vertical motion using L.A.B. Palletizer Transportation Simulator #501 Taped Top and Bottom Flaps CRITERIA FOR PASSING THE TEST Immediately following the period of vibration, each package must be removed from the platform, turned on its side and observed for any evidence of leakage. A packaging passes the vibration test if there is no rupture or leakage from any of the packages. No test sample should show any deterioration which could adversely affect transportation safety or any distortion liable to reduce packaging strength. ( 178.608) VIBRATION TEST SET-UP & RESULTS Sample # Results Comments / Observations 11 PASS 12 PASS No leakage or damage. 13 PASS

Page 14 of 18 REPETITIVE SHOCK VIBRATION TESTS Taped Top and Glued Bottom Flaps TEST CONTENTS: TEST INFORMATION Water SAMPLE PREPARATION: Refer to Section II CONDITIONING: 73 F / 50% RH, Chamber #202 TABLE DISPLACEMENT: 1 TEST FREQUENCY: TEST DURATION: TEST EQUIPMENT: 3.6 Hz 1 Hour Vertical motion using L.A.B. Palletizer Transportation Simulator #501 CRITERIA FOR PASSING THE TEST Immediately following the period of vibration, each package must be removed from the platform, turned on its side and observed for any evidence of leakage. A packaging passes the vibration test if there is no rupture or leakage from any of the packages. No test sample should show any deterioration which could adversely affect transportation safety or any distortion liable to reduce packaging strength. ( 178.608) VIBRATION TEST SET-UP & RESULTS Sample # Results Comments / Observations 14 PASS 15 PASS No leakage or damage. 16 PASS

Page 15 of 18 COBB WATER ABSORPTION TESTS TEST INFORMATION SAMPLE SIZE: (5) 5 x 5 Squares CONDITIONING: 73 F / 50% RH, Chamber #202 WATER APPLIED: 100mL / Sample TEST DURATION: 30 Minutes / Sample TEST EQUIPMENT: UWE Analytical Balance #102 Gurley Cobb Water Absorption Apparatus CRITERIA FOR PASSING THE TEST An increase in mass greater than 155 g/m² over the 30 minute duration represents an unacceptable level of water resistance. ( 178.516) COBB WATER ABSORPTION TEST RESULTS Sample # Water Absorbed (g/m²) 1 103 g/m² 2 94 g/m² 3 99 g/m² 4 119 g/m² 5 110 g/m² AVERAGE: RESULT 105.0 g/m² PASS

Page 16 of 18 REGULATORY AND INDUSTRY STANDARD REFERENCES REGULATORY REFERENCES 49 CFR UN IMDG ICAO IATA TEST 2008 Edition 15th Edition 2008 Edition 09-10 Edition 50th Edition Drop: 178.603 6.1.5.3 6.1.5.3 6; 4.3 6.3.3 Stacking: 178.606 6.1.5.6 6.1.5.6 6; 4.6 6.3.6 Pressure: 173.27(c) 4.1.1.4.1 --- 4; 1.1.6 5.0.2.9 Vibration: 178.608 --- --- 4; 1.1.1 5.0.2.7 Cobb: 178.516 6.1.4.12.1 6.1.4.12.1 6; 3.1.11.1 6.2.12.2 United States Department of Transportation Code of Federal Regulations (CFR) Title 49, Transportation, Parts 100-199 The United Nations Recommendations on the Transport of Dangerous Goods Model Regulations. (UN Orange Book) International Maritime Dangerous Goods Code (IMDG) Technical Instructions for the Safe Transport of Dangerous Goods by Air (ICAO) International Air Transport Association (IATA) Dangerous Goods Regulations INDUSTRY STANDARD REFERENCES Drop: ASTM D5276: Standard Test Method for Drop Test of Loaded Containers by Free Fall ISO 2248: Packaging Complete, Filled Transport Packages Vertical Impact Test By Dropping Stacking: ASTM D4577: Standard Test Method for Compression Resistance of a Container Under Constant Load ISO 2234: Packaging Complete, Filled Transport Packages Stacking Tests using Static Load Vibration: ASTM D999: Standard Test Method for Vibration Testing of Shipping Containers ISO 2247: Packaging Complete, Filled transport Packages Vibration Test at Fixed Low Frequency Cobb: ISO 535: Paper and Board - Determination of Water Absorption - Cobb Method American Society for Testing and Materials (ASTM) International Organization for Standardization (ISO) EQUIPMENT All inspection, measuring and test equipment that can affect product quality is calibrated and adjusted at prescribed intervals, or prior to use, and is traceable to NIST, using ANSI Z540 as an overall guide for calibration certification.

Page 17 of 18 SECTION IV: MATHEMATICAL CALCULATIONS INFORMATION USED FOR CALCULATIONS Overall Package Tare Weight (PTW): 1,558 Grams Overflow Capacity (OFC): Methanol/Water SG Methanol/Water 3,754 Grams SG: 0.970 Water Number of Inner Packagings (# IP): Packing Group Product Specific Gravity (PSG): Packing Group Multiplication Factor (MF): 3,870 Grams 4 II 1.6 1.00 Overall Height of one Package (OH): 13.88 Inches Stack Test-# of Samples Tested Simultaneously: 3 98% OF OVERFLOW Overflow Capacity (OFC) x 98% OFC x 98% 3,754 x 98% = 3,679 Grams Methanol/Water 3,870 x 98% = 3,793 Grams Water PACKAGE TEST WEIGHTS Overall Pkg Tare Weight (PTW) + (98% Overflow Capacity (OFC) x # of Inner Pkg (# IP) PTW + (98% OFC x # IP) 1,558 + 3,679 x 4 Methanol/Water 1,558 + 3,793 x 4 Water Methanol/Water: 16.2 Kg 35.7 Lbs. Water: 16.7 Kg 36.8 Lbs. AUTHORIZED PACKAGE GROSS MASS CALCULATION (APGM) Overall Pkg Tare Weight (PTW) + (Product SG (PSG) x 98% Overflow (OFC) x # of Inner Pkg (# IP)) PTW + (PSG x 98% OFC x # IP) 1,558 + 1.6 x 3,793 x 4 25.8 Kg 56.8 Lbs.

Page 18 of 18 DROP HEIGHT Calculation For Product Specific Gravities Exceeding 1.2 Product Specific Gravity (PSG) x Packing Group Multiplication Factor (MF) PSG x MF Packing Group: II 1.6 x 1.00 Required Drop Height Actual Drop Height 1.60 Meter 63.0 Inches 63 Inches STACKING TEST MINIMUM LOAD CALCULATIONS Number of Packages in a 3m High Stack (118 / Overall Pkg Height (OH) -1) 118 / Overall Height of one Pkg (OH) - 1 (118 / OH) -1 = # 3m HS 118 / 13.88-1 = 7.5 Stacking Test Load Calculation (Individual Package) Authorized Pkg Gross Mass (APGM) x # of Pkg in a 3m High Stack (# 3m HS) APGM x # 3m HS 25.8 x 7.5 193.5 Kg 426.6 Lbs. Stacking Test Load Calculation Samples x Authorized Pkg Gross Mass (APGM) x # of Pkg in a 3m High Stack (# 3m HS) Samples x (APGM x # 3m HS) 3 x 25.8 x 7.5 580.5 Kg 1,279.8 Lbs.