Field Service. Vantage Recycler Connections, Installation and Setup

Similar documents
Thank you for purchasing the SC-CONVERSION System 500/600 Conversion Kit. This Kit is available in two different versions:

National Vendors Changetron 2/4 Validator Installation Instructions

Vista 2-NT / Vista 3 & Suprema

Operation and Service Manual

$250 Capacity ChangeMaker Operator s Manual

SYSTEM 600 GENERAL MAINTENANCE AND ADJUSTMENT GUIDE

ATTENTION: OBSERVE PRECAUTIONS FOR HANDLING ELECTROSTATIC DEVICES

BANKNOTE READER BT-11

CashCode. MSM BackLoad Bill Validator

AquaFlow Intl Inc. Automated Bulk Water Loading Stations. AquaVendor RFID Card Based System. System User Guide

FITTING AND OPERATION OF THE VILLA INTERCOM

LIFT CONTROL WITH HIGH LEVEL INTERFACE (V3 OR LATER)

Fun Industries Inc. G100D Grabber Deluxe Operation Instructions

Model S-2200 Single Pocket Currency Discriminator Operating Manual

1 MODULAR SERIES - FRONT LOAD. CANADIAN PRODUCT PRICE LIST - Effective July 1, 2014 PRICE PRICE MC100 MC200 MC700 MC720

WELCOME. Standard Change Makers, Inc. Changer Maintenance Overview General Maintenance Guide for Standard Change-Makers Machines

COST RECOVERY, ACCESS, & SELF-SERVICE PAYMENT SOLUTIONS. PRODUCT CATALOG YOUR PARTNER FOR OVER 30 YEARS

Bike Fixtation LLC th Ave S, Unit 1 Minneapolis, MN Phone:

TF20 Tray Feeder. Instruction Manual. for JEDEC and IEC Standard Trays

POS 108 USER MANUAL V 2.1

People love to use our machine! It's like owning a 24-hour "convenience store" right in their business!

STANDARD CHANGE-MAKERS, INC. Indianapolis, Indiana

EU1000 CRIMPER OPERATORS MANUAL WITH ACTTM CONTROLLER

Setup Guide. Snackvendor Models 170/ Enterprise Way Bridgeton, MO (314) August,

SUBJECT ADTC TO U11 CONTROLLER FIELD RETROFIT

HARBORTOUCH ECHO USER GUIDE HARBORTOUCH SUPPORT LINE:

SYSTEM 600 BILL CHANGER INSTALLATION INSTRUCTIONS Congratulations...

C.A.R.D.S. ( Cashless Arcade/Redemption Debit System )

V21 Parts & Service Manual All V21 Identified Equipment REV A 10/2013 P/N: GENERAL INFORMATION. V21 General Information G-1


Power Distribution Module Replacement Instructions

Version Software User Guide

Magner /35-3 Series Currency Counter. Operator's Manual

Moving money forward UV MG

228 EXPRESS CASH RECYCLER 8, 10 OR 12 ROLLED STORAGE MODULES IN A UL SAFE (FRONT LOAD) PERSPECTIVE PLAN VIEW PAGE 1 OF 5

QUICK REFERENCE GUIDE

2005/01. GV-Data Capture

ALLIED ELECTRONICS, INC STATION SITE CONTROLLER (SSC) Installation and Start Up Guide. ARCO / ANDI to Tokheim

Wireless Freezer Manual Installation Guide

GV-Data Capture V2 User's Manual

OHIO WinStation (TVM) Lottery Terminal Manual

Confectionary Vender DN-700CV

Multi-door Networking Controller

Cash Drawer Identification

X30 System Components

Integrated Payment Processing. User Guide V0409

! CAUTION: Read and follow these instructions.

ST-07 Series. Bill Validators. Operation Manual

TOC600 ANALYZER S TANDARD OPERATING P ROCEDURES

OneSource Daily Tasks for Managers

Cash Cassettes and Cash Drawers

Loading media 1. Loading paper, card stock, or labels Loading transparencies Loading envelopes. Printing. Using color. Paper handling.

MONARCH 9416 XL KNIFE ADDENDUM

COLD BEVERAGE MERCHANDISER

TERMINAL STRUCTURE YOUR VX520 TERMINAL

Paymark EFTPOS (LEGACY) Pax S80c One-Piece / S90c Mobile

Installation & Calibration Manual

Delaying Count. Totaling the Register THEN

RNS, DRS, & ER-60 M-Line Operational Manual

Payment Center User Manual

Volume MMF POS. Instruction Manual /User Guide

HF2000 HF3000 HF2500 HF3500. Operator s Manual. Seaga Manufacturing, Inc. 700 Seaga Drive Freeport, IL USA

SCR Advance. SCR Advance. Description. Benefits

MSI Cash Register Version 7.5

AVANTI VENDING CATALOG. 100% Financing Available ADA Ready

EB-300 / EB-310. Simple Counter with Detection. (Counting/Detecting) SERVICE MANUAL

Table of Contents. Installation 2-10 Leveler legs... 2 Controller... 4 Dip-switch Configurations. 5 Wire Harness Installation.. 7

American Changer. AC2078 Installation, Operation, and Service Manual. Changing the Industry

SmartCard Reader Error Codes

Storm Drone 6 GPS DEVO 7 Setup for NAZA-M Lite

Section 17: Pallet Changer

VIDEOTRONIK 2.0 CANBUS and RESISTIVE steering wheel commands adapter, Parking Sensor and climate control systems displaying

Elevator control setup with Entrapass Special or Corporate edition with KT-400

Troubleshooting Guide 9702 Series

Whatever Your Storage and Tool Management Needs the New MATRIX Series 5 is the Ultimate Solution

2-Position T1/HDSL Environmental Mounting Assembly Model EM02-0xx

Operational Manual for the HV-X Validator

MR210 RACING QUAD USER MANUAL

Installation & Calibration

AUTOMATIC PRODUCTS international, ltd.

FLEXPAK TM 3000 TWO-BUTTON PROGRAMMING SET-UP / CONFIGURATION / TROUBLESHOOTING / OPERATION / PARTS MANUAL

CONTRACT AWARD NOTIFICATION

IRIS Serial Configuration for Galaxy Upload/Download Connections:

LAN Installation Instructions. Converts John Deere Platform Heads with Reel Fore/Aft to Single Point Hydraulic & Electrical Connection

AquaFlow Int l, Inc.

COMBO VENDOR MODEL 3589 SERVICE MANUAL

HOBO Plug Load Logger (UX ) Manual

OHIO WinStation (TVM) Lottery Terminal Manual

U.S.A. 540MVP VIDEO GAMING MACHINE OPERATOR MANUAL

Mounting Screw. Channel Filler. Light Angle Adjustable Screw. LED Board Vertical stud and blocking Locking Nose. Driver.

ALLIED ELECTRONICS, INC STATION SITE CONTROLLER (SSC) Installation and Start Up Guide. ARCO / ANDI to Wayne PIB

Section 6 Bill Validator VMC/Peripheral Communication Specifications

Four Stacker Card Dispenser

LIFT-SLIDING. Semi-Automated Parking System

DESIGNERS AND BUILDERS OF CURRENCY CHANGERS AND ALLIED SYSTEMS SINCE 1921 FOR RLC-2 / RLC-3. Manual Part No Revision No.

This product has been tested and certified to conform to ASTM F2456, Youth Resistant Firearms Container.

User Manual. XK315A1 water proof series Weighing Indicators. Applications: Electronic platform scale, weighing scale, etc.

I. VersaCall Modules Data Input & Machine Interface Module Machine Interface Modules Receives Inputs Directly from CNC Machine Wired

Volume MMF POS. Instruction Manual /User Guide

Single Stacker Operational Manual

Transcription:

Field Service Vantage Recycler Connections, Installation and Setup

Vantage Recycler Installation Instructions 1. Disconnect power from the machine. 2. Remove the existing MDB bill acceptor and harnesses. 3. Determine if there is enough room to install a Vantage Recycler in your machine. If there is not enough depth or height, the Vantage recycler can not be installed or you will need to modify the machine for the needed clearance. For Vantages with a B style bezel (mask) The depth from the bill acceptor mounting surface to the back of the cabinet or inner door must be at least 6 inches. The height from the top mounting studs for the bill acceptor must be at least 6½ inches. For Vantages with an R or S style bezel (mask) The depth from the bill acceptor mounting surface to the back of the cabinet or inner door must be at least 6 and 3/4 inches. The height from the top mounting studs for the bill acceptor must be at least 8¼ inches. 4. The Vantage Recycler is made up of 5 components: Bill Inlet Bezel Vantage Bill Acceptor Vantage Recycler Unit Vantage Recycler Bill Box Controller Adapter Box (409433) These components are easily removed to simplify the installation process. 5. Remove the Bill Inlet Bezel from the Vantage bill acceptor and fasten the Bezel to the machine. 6. Remove the bill box from the Recycler unit. 7. Remove the Recycler from the Vantage bill acceptor. 8. Connect the Vantage MDB harness (409415) black connector to the MDB port on the side of the Vantage bill acceptor. 5

9. Install the Vantage bill acceptor onto the Bill Inlet Bezel. Align the bill acceptor with the bezel and push the bill acceptor body into the bezel until it locks in place. Be sure that both sides are locked into place. 10. Attach the Vantage Recycler module to the Vantage bill acceptor. 11. Connect the Recycler s MDB harness first to the coin changer, 6 then to the Vantage bill acceptor s MDB harness. 4 12. Connect the Recycler s 4-pin male Data harness to the Vantage bill acceptor s data port. 7 The 4-pin female Data harness connector is not used. 13. Install the Recycler s bill box. 14. In most machines, (not using MDB Specification Level 4), the use of a controller adapter box (409433) is required to allow the machine to correctly communicate to the bill recycler. Connect the male MDB connector from the Vantage bill acceptor to the Controller Adapter Box. 3 15. Connect the black plug of the MDB adapter box harness 409415 to the Adapter Box end labeled Machine Controller Connection. 16. Install the Adapter Box in the machine using the supplied Velcro strip. 2 17. Connect the MDB harness from the machine to the Adapter Box MDB Harness. 1 NOTE: The output of the Controller Adapter Box labeled Currency Systems Connection should ONLY be connected to the coin changer, bill acceptor, and recycler. If your machine has other MDB devices such as Card Readers, they must be connected to the machine s MDB harness BEFORE connecting to the Controller Adapter Box. 18. Once all harness connections are made, use tie wraps to dress-up and secure the MDB wires from moving parts in the machine. Be sure cables and connectors will not get pinched when the door is closed. 19. Apply power to the machine.

Setup After Installation and Programming the Recycler 1. After installation, power up machine. The following will happen: The Recycler will stack. The Recycler Status LED is green. The Vantage Status LED is green. The two digit display will show how many bills are in the recycler bill box. 00 will be displayed on a new unit indicating there are no bills in the Recycler. The bill acceptor inlet will begin to flash. The bill acceptor Smart Bezel will display bills that are currently being accepted. If using the Controller Adapter Box, the red power LED should be ON solid. The Controller Adapter Box also has two sets of green and yellow LED s to indicate two way communication between the vending machine, Bill Acceptor, Recycler, and the Coin Changer. These green and yellow LED s should be constantly blinking. 2. There are 3 red push button switches on the Recycler used for programming, testing, and filling bills to be recycled. Menu Scroll Enter Using these buttons (called user interface), run through the Menu Options below. Be sure to set the BR to 01 if you want $1 bills to be paid out or 05 if you want $5 bills to be paid out. This will determine which bills are stacked in the Recycler cashbox.. Recycler Menu Options D1 Dispense Dispenses one recycled bill at a time. AF Auto Fill Allows preloading of bills into the Recycler without creating a machine credit. FL Float Level Allows user to set how many bills (max) will be allowed in the recycler bill box. Bills can be set from 0 30. Default is 30. If set to 0, no bills will be recycled. BR Bills Recycled (for Pay Out) 01 = $1 bills will be paid out 05 = $5 bills will be paid out CL Changer Lock-Out If the Recycler bills is lower than the minimum number bills set, the high denomination bills will be disabled. (The Smart Bezel will indicate this by lighting the $1 s Only LED). This preserves coins in the changer by preventing large paybacks. To accept high denomination bills, make sure the bills are enabled on the Vantage and that you have available equal or more bills than what is set by the CL. The scroll button will cycle between 1 and 20 bills. If the setting remains at 0, then high denomination bills will be accepted as normal as long as there are sufficient coins in the coin changer.

DC Dispense Counter Number of bills paid out. The Dispense Counter value is divided into two parts due to only having 2 digits available. Look at the example shown below: Example: ($109) 109 bills has been paid out from the Recycler. DC (Dispense Counter) [ENTER] 01 (high side of the 0109) [SCROLL] 09 (low side of the 0109) [SCROLL] DN (Done) [SCROLL will take you to the next Menu Item] [ENTER will clear the 0109 to 0000 ] The Dispense Counter WILL NOT subtract bills that are dispensed through the D1 dispense mode. 3. The Smart Bezel located on front of the Vantage bill acceptor tells the customer which bills can be accepted. If the left LED is ON then the unit is only accepting $1 bills because it can only make change for a $1 bill. If the right LED is ON then the unit is accepting $1 s and $5 s because change can be made for them. You must have coins in the changer before any bills are accepted. Make sure the Vantage has the $1 and $5 dollar bills enabled. NOTE: If you have to enable the $5 or make any other Option changes on the Vantage bill acceptor, make sure the Recycler Data Port connector remains attached to the bill acceptor when you make these changes. Miscellaneous Notes The Recycler works on Vantage VX or VL models in MDB mode only. The Recycler Controller Adapter CA# 409433 must be used in all machines that IS NOT compliant with MDB/ICP Spec Version 4 or higher. The Recycler bill box capacity is 30 bills. A Card Reader must be installed on the machine MDB side, not the Controller Adapter Box side. The Vantage Inlet LED s will flash when you are in the Auto-Fill mode so bills will not accumulate credit. The Vantage and Recycler will not enable unless the changer has coins. For proper operation, DO NOT manually pre-load bills in the Recycler bill box. ALL Recycler bills must be loaded through the bill inlet.

Coin Acceptors, Inc. U.S. World Headquarters 300 Hunter Avenue St. Louis, MO. 63124 (314) 725-0100 1-800-325-2646 Email: techsupport@coinco.com www.coinco.com VantageRecyclerInstallationAndSetup.doc JN - REV. 02-24-11