C08. S04. P02 P08 Tiling

Similar documents
Tiling Tiling Finishes C08

Tiling Tiling

Tiling. Tiling.

Tiling. Capital Gate Hotel, Abu Dhabi - UAE

CO8 Finishes. Finishes C08. Introduction - Plaster skimming 29/03/2018 Jointing 29/03/2018 Tiling 29/03/2018 Decorative effects 29/03/2018

Curved partition and wall lining system

GypLyner. GypLyner. Metal framed wall lining system. All our systems are covered by SpecSure when using genuine Gyproc and Isover products.

GypWall TM ROBUST 4.4. GypWall ROBUST. Durable impact resistant partition system. Key facts. Sector Guide

Internal walls. Creating perfect living spaces. Technical Advice Centre Tel:

Quantity take-off details

C04. S05. P02 P14 GypWall quiet sf

DriLyner 5.2. DriLyner. Drywall masonry lining systems. Key facts. Sector Guide

C05. S03. P02 P08 FireWall

GypLyner UNIVERSAL Metal framed wall lining system

GypWall RAPID db Plus

GypLyner IWL Independent wall lining system

C05. S03. P02 P08 FireWall

C07. S04. P02 P10 GypLyner universal

C04. S11. P02 P13 Non-loadbearing timber stud

C06. S05. P02 P12 GypFloor silent

C06. S05. P02 P12 GypFloor silent

Boards. Products - Boards.

Single frame acoustic separating wall system

GypLyner UNIVERSAL Metal framed wall lining system

Staggered stud acoustic partition system

Independent twin frame high performance acoustic separating wall system

GypLyner framed structural steel encasement system

GypWall QUIET Acoustic separating wall system

Staggered stud acoustic partition system

The extra strong, extra durable, sound resistant system that you can direct fix to

ShaftWall. Shaft and duct encasement system. ShaftWall.

Creating perfect living spaces. Shaping spaces for living, with internal lining solutions that enhance lifestyles. Creating perfect living spaces

C08. S02. P02 P08 Plaster skimming

CO3. Steel encasements C03. Introduction - FireCase 01/12/2017 GypLyner encase 11/05/2017. Introduction Steel encasements

C07. S03. P02 P24 DriLyner basic, tl, mf, rf

GypFloor SILENT 6.4. Sound insulating floor system. Key facts. Sector Guide

Loadbearing timber joist floors

GypLyner UNIVERSAL (Ceilings)

GypWall AUDIO The ultimate sound insulating wall system

Plaster skimming. Plaster skimming to plasterboard is a popular method of providing a smooth, seamless surface ready to receive decorative treatment

Issue date: 1st May Key changes since original publication (July 2005):

Cavity fire barriers. Cavity fire barriers. Fire separation within concealed spaces. C06 Floors and ceilings

The ultimate sound insulating wall system

GypLyner UNIVERSAL Concealed grid ceiling lining system

The ultimate impact resistant partition

Single frame acoustic separating wall system

CO5. Specialist partitions C05. Introduction - ShaftWall 29/03/2018 FireWall 29/03/2018 GypWall curve 16/12/2016 GypWall secure 29/03/2018 BlastWall -

C06. S06. P02 P20 Loadbearing timber joist floors

Plasterboard selector guide Dedicated to plasterboard

GypWall QUIET Acoustic separating wall system

Selecting partitions

The new high-performance lining for internal and external applications INSIDE OR OUT YOUR CHOICE

GypLyner UNIVERSAL Concealed grid ceiling lining system

ShaftWall. Shaft and duct encasement system. ShaftWall.

GypLyner (walls) Metal framed wall lining system. GypLyner.

GypWall TM EXTREME. GypWall EXTREME 4.5. Ultimate impact and abrasion resistant partition system. Key facts. Sector Guide

GypLyner (Ceilings) Concealed grid ceiling lining system. GypLyner UNIVERSAL.

book2_jan10a:products-r10 (07-04).qxd 15/04/ :09 Page 49 Gyproc Plasterboard 2

ting Join Jointing Finishes C08

C05. S02. P02 P30 ShaftWall

FireWall. High performance fire-resistant wall system. FireWall.

CasoLine MF Concealed grid MF suspended ceiling system

CO9. Sound absorbing solutions C09

GypWall AUDIO The ultimate cinema wall system

CHAPTER 10: Finishes CONTENTS 10.1 PLASTERWORK ND AND 3 RD FIX FINISHES

SOUND SOLUTIONS FOR YOUR HOME. Controlling the volume of everyday living How to solve a problem you have with noise

October Plasterboard baffle. Hilti CP617 Putty Pad. Socket detailing. White Book supplement

Plasterboard accessories - Products

Separating walls. Separating walls. Creating quiet, comfortable and safe living environments between adjoining homes.

Gypwall systems. incorporating Gyproc Habito

CHAPTER 10: Finishes CONTENTS 10.1 PLASTERWORK 10.2 SECOND AND THIRD FIX FINISHES. Chapter 10

CasoLine mf. Concealed monolithic metal frame suspended ceiling system

CasoLine MF Concealed grid MF suspended ceiling system

Separating walls. Separating walls. Creating quiet, comfortable and safe living environments between adjoining homes.

Gypframe profiles. Dimensional specifications

Selecting floors and ceilings

22 The Lowry Centre, Salford

C06. S02. P02 P22 CasoLine mf

C09. S02. P02 P14 CasoLine mf

FireCase. Frameless structural steel encasement system. FireCase.

Technical performance and principles of system design

SOUND SOLUTIONS FOR YOUR HOME. Controlling the volume of everyday living How to solve a problem you have with noise

Sheathing Board Xtra protection, built in.

Gypframe profiles. Dimensional specifications

Gypframe profiles. Dimensional specifications

Issue date: 15th January Key changes since original publication (July 2005):

Semi-exposed soffits. Thermal lining system for semi-exposed soffits. Semi-exposed soffits.

Separating walls. Countryside Properties, Lock 38, Stoke-on-Trent

promise Comprises only the highest quality components, designed to work individually and together to deliver the specified level of performance.

SoffitLine. Thermal lining system for semi-exposed soffits. SoffitLine.

FIRE PROTECTION. GTEC Shaftwall systems 244 GTEC Shaftwall Stairwell systems 248 GTEC Horizontal Shaftwall systems 249 GTEC Encasement systems 250

Rigidur h for off-site applications Product Data Sheet

HOW TO: BOARD ROOMS WITH HIGH HUMIDITY AND CONDENSATION GTEC MOISTURE AND VAPOUR BOARD WITH PLASTERBOARD

Wall Linings. As well as complete dry lining solutions we also provide fast-drying parge coat to ensure airtightness,

WORK, REST AND PLAY ISOVER MAKES IT POSSIBLE.

Knauf Wall Liner. Head Track. Brackets. Wall Lining Stud. Fixings. Knauf Plasterboard. Floor Track. 98 Wall Liner

The Revolutionary New Plasterboard TIMBER FRAME GUIDE

Wet Areas Using Plasterboard

HOW TO: BOARD BATHROOMS, WET ROOMS & SHOWERS

Transcription:

! This section includes updated information, added since it was first published in December 2015. Last updated 29/03/2018 C08. S04. P02 P08 Including C08. S01. P02 Finishes introduction

C08 Finishes Introduction Finishes Essential to all our high performance systems is our full range of finishing products

Finishes British Gypsum s range of finishes provide everything needed to complete the wall lining, partition, floor and ceiling systems, regardless of the size and complexity of the project specification. Plaster skimming to plasterboard is a popular method of providing a smooth, seamless surface ready to receive decorative treatment. Alternatively our jointing materials produce durable joint reinforcement and a smooth, continuous, crack-resistant surface ready for priming and final decoration. The range of boards available for tiling offers flexibility of design and peace of mind when installed in both wall linings and lightweight partition systems. To relieve flat runs of lining, joints and angles, and to enhance walls and ceilings, a variety of decorative effects are available which can be installed simply and quickly. Plaster skimming - C08. S02. P02 Jointing - C08. S03. P02 - C08. S04. P02 Decorative effects - C08. S05. P02 Introduction Finishes C08 You may also be interested in... If you are looking for finishes with high sustainability credentials then Thistle plasters have attained BES 6001 Excellent. We have also developed EPDs for a number of our plasters range. Refer to C08. S01. P51 Sustainability. 0115 945 6123 bgtechnical.enquiries@bpb.com C08. S01. P02

C08 Finishes In rooms subject to high or intermittent moisture conditions, the range of boards available for tiling offers flexibility of design and peace of mind when installed in both wall linings, lightweight partition system and floor systems All our systems are covered by SpecSure when using genuine British Gypsum and Saint-Gobain Isover products

Specifically designed for direct tiling applications, Glasroc H tilebacker is the ideal substrate for tiling in environments subjected to moisture, providing protection for shower enclosures, bathrooms, swimming pool halls and adjacent areas. For wall areas where intermittent moisture conditions are more common, including kitchens and bathrooms, Gyproc moisture resistant grade boards are suitable. Key benefits Glasroc H tilebacker has been designed for use in high moisture applications Glasroc H tilebacker will hold tiling systems up to 32kg/m² on walls and 50kg/m² on floors Gyproc moisture resistant grade boards are suitable for use in walls in intermittent moisture conditions Finishes C08 You may also be interested in... If you require acoustic insulation or fire resistance performance, GypWall classic partition systems, incorporating Glasroc H tilebacker are available. Refer to C04. S02. P02 GypWall classic 0115 945 6123 bgtechnical.enquiries@bpb.com C08. S04. P02

C08 Finishes performance Table 1 on partition systems Partition system Board type 3 Stud centres mm Additional support / comments GypWall classic, 1 x 12.5mm Glasroc H tilebacker each side 600 - GypWall robust, GypWall extreme / Hybrid GypWall quiet, GypWall quiet iwl and GypWall audio GypWall quiet sf GypWall staggered Inner layer 12.5mm (minimum) Gyproc plasterboard and outer layer 1 x 12.5 Glasroc H tilebacker each side 1 x 15mm Gyproc plasterboard each side or 2 x 12.5mm (minimum) Gyproc plasterboard each side 1 x 15mm Gyproc plasterboard (or 15mm Rigidur h where appropriate) each side or 2 x 12.5mm (minimum) Gyproc plasterboard each side (including outer layer Rigidur h where appropriate) Inner layer 12.5mm (minimum) Gyproc plasterboard and outer layer 1 x 12.5 Glasroc H tilebacker each side 2 x 12.5mm (minimum) Gyproc plasterboard each side Tiles over double layer lining board fixed on Gypframe RB1 Resilient Bar side Tiles over double layer lining board fixed to studs (non Gypframe RB1 Resilient Bar side) 1 x 15mm Gyproc SoundBloc each side 2 x 12.5mm (minimum) Gyproc SoundBloc each side 600-400 If using Gypframe 146mm studs, they can be located at 600mm centres to full partition height with extra studs to give 300mm centres up to tiling height 400 If using Gypframe 146mm studs, they can be located at 600mm centres to full partition height with extra studs to give 300mm centres up to tiling height 600-400 - 600 1 Horizontal Gypframe RB1 Resilient Bar at 400mm vertical centres 400 1-400 - GypWall rapid db Plus 1 x 15mm Gyproc SoundBloc rapid each side 450 Or studs at 900mm centres with noggings at mid-height Timber stud partitions and separating walls 12.5mm Gyproc plasterboard each side (single or double layer) 15mm Gyproc plasterboard each side (single or double layer) 400 Timber noggings 50 x 38mm minimum at 600mm vertical centres 600 Timber noggings 50 x 38mm minimum at 600mm vertical centres ShaftWall 1 x 15mm Gyproc FireLine 300-2 x 12.5mm (minimum) Gyproc FireLine 600 Gyproc Sealant applied in a full height continuous vertical bead midway between studs FireWall 2 x 15mm Gyproc plasterboard 2 400-1 If the tiling side is unknown, or tiling is to both sides, the studs should be at 400mm centres and the horizontal Gypframe RB1 Resilient Bars at 400mm vertical centres. 2 FireWall specifications incorporating outer layer 6mm Glasroc F multiboard are suitable for tiling. 3 Moisture Resistant variant should be used unless in a totally dry area. Also refer to table 3. An outer layer of Glasroc H tilebacker 12.5mm can be added if appropriate to the system. Reducing the centres of the metal studs within GypWall partition systems can have a detrimental effect on the sound insulation performance of the system. Refer to C02. S01. P30 Robustness. The recommendations given are based on experience and laboratory / site testing. In practice, performance will be dependent on factors such as workmanship and site conditions. C08. S04. P03 british-gypsum.com

performance (continued) Table 2 on wall lining systems Wall lining system Board type 3 Support centres mm DriLyner basic 2 Dabs of Gyproc DriWall Adhesive in rows DriLyner ti 2 Dabs of Gyproc DriWall Adhesive in rows DriLyner mf 2 Metal furring on dabs of adhesive in rows DriLyner rf 2 Blobs of Gyproc Sealant at nominal 300mm centres GypLyner universal Additional support / comments 12.5mm Glasroc H tilebacker 600 Horizontal dabs of Gyproc DriWall Adhesive at mid-storey height Nine Gyproc Nailable Plugs through each board 1 9.5mm Gyproc WallBoard (1200mm wide) 400 For 9.5mm Gyproc WallBoard (900mm wide) support centres can be at 450mm Horizontal dabs of Gyproc DriWall Adhesive at mid-storey height 12.5mm or 15mm Gyproc plasterboard 600 Horizontal dabs of Gyproc DriWall Adhesive at mid-storey height Gyproc ThermaLine laminates 600 Horizontal dabs of Gyproc DriWall Adhesive at mid-storey height Nine Gyproc Nailable Plugs through each board 12.5mm Glasroc H tilebacker 12.5mm or 15mm Gyproc plasterboard Gyproc ThermaLine laminates 12.5mm Glasroc H tilebacker Gyproc ThermaLine laminates 12.5mm Glasroc H tilebacker 12.5mm or 15mm Gyproc plasterboard (single or double layer) Gyproc ThermaLine laminates 400 British Gypsum Drywall Screw at 300mm centres into each MF support 300 Nine Gyproc Nailable Plugs through each board 1 400 Fixing brackets at 600mm vertical centres GypLyner iwl 1 x 12.5mm Glasroc H tilebacker 600 Mid-height support from background structure to framework Timber battens 1 x 15mm Gyproc plasterboard or Gyproc ThermaLine laminates 2 x 12.5mm (minimum) Gyproc plasterboard / Gyproc ThermaLine laminates 12.5mm Glasroc H tilebacker 12.5mm or 15mm Gyproc plasterboard (single or double layer) Gyproc ThermaLine laminates 1 900mm x 1200mm Glasroc H tilebacker boards require three Gyproc Nailable Plugs per board. 2 These lining systems should be left to stand for seven days before tiling begins. 3 Moisture Resistant variant should be used unless in a totally dry area. Also refer to table 3. 400 Mid-height support from background structure to framework 400-400 Horizontal battens at head, base and intermediate positions not exceeding 1200mm centres Finishes C08 The recommendations given are based on experience and laboratory / site testing. In practice, performance will be dependent on factors such as workmanship and site conditions. 0115 945 6123 bgtechnical.enquiries@bpb.com C08. S04. P04

C08 Finishes design Choosing tiling boards When designing wall linings and lightweight partition systems, the following guidance details the recommended board, application and details to use. Table 3 Board lining requirements Level of moisture Typical wall application Board Low Medium High Extreme Planning - key factors Glasroc H tilebacker is recommended for use as a tile backing substrate in environments subjected to moisture. The board can be used on both wall linings, lightweight partition systems and existing timber floors. Glasroc H tilebacker is not a structural grade flooring board and cannot be used as a walking surface. Where the board is installed using the DriLyner systems, ensure the Gyproc DriWall Adhesive has set seven days before tiles are applied to the board surface. The tolerance on the finished tile surface quoted in BS 5385: Part 1, i.e. 3mm under a 2m straight edge with thin-bed adhesives, is such that it will reflect very accurately the standard of the background surface. Moisture resistance Residential Splash backs Kitchens Toilets Residential Bathrooms Residential Shower enclosure walls Commercial Kitchens Changing rooms Commercial Communal shower walls Swimming pool hall walls 1 In extreme moisture environments, Glasroc H tilebacker should be treated with a suitable tanking system. Guidance for high to extreme moisture environments Perimeter and junction sealing Designers must give consideration to the precautions necessary at junctions to ensure that moisture is not allowed to penetrate or collect. Cut edges of boards must be appropriately sealed and waterproofed at abutments. Waterproof sealant should be used around baths or shower trays, between the wall surface and the floor at the base of partition or wall lining, to prevent any possible moisture being absorbed by the board core. Tanking systems Gyproc Moisture Resistant, mr variants, Glasroc F multiboard and Rigidur h Gyproc Moisture Resistant and mr variants, Glasroc H tilebacker, Glasroc F multiboard and Rigidur h Glasroc H tilebacker Glasroc H tilebacker Glasroc H tilebacker 1 In extreme moisture environments, the exposed surfaces of Glasroc H tilebacker should be treated with a suitable tanking system. Glasroc H tilebacker should not be exposed to running water. Care should be taken not to over tighten screws when fixing boards and all screw heads should be fully filled with adhesive. Continuity of linings All partitions and wall linings should be complete. There should be no omissions to board linings, e.g. behind baths. In areas of high and extreme moisture and humidity, extra care should be given to detailing at junctions, perimeter sealing and tiling. C08. S04. P05 british-gypsum.com

design (continued) Before tiling commences, fully fill all edge joints included in the tiling area with tile adhesive. Install tiles following the manufacturer s guidance, using a waterproof tile adhesive. Tiles can be applied directly to the pre-primed surface of Glasroc H tilebacker, ensuring the board is dust free prior to tiling. Ensure tiles are sealed using a waterproof grout and sealant at perimeters. Timber stud external walls or partitions Where tiling is specified, designers should ensure that the timber is of sufficient dimensions to give a stable base for the additional loading. The moisture resistance of the timber should be within the limits given in BS 5268: Structural use of timber - Part 2. Underfloor heating systems Glasroc H tilebacker is suitable for use in conjunction with electric underfloor heating systems. Glasroc H tilebacker is installed as per standard installation, electric underfloor heating systems should be installed in accordance with manufacturers installation details. The operating temperature of the heating system should not exceed 40 C. Guidance for low to medium moisture environments Planning key factors Glasroc H tilebacker, Gyproc moisture resistant grade boards, Glasroc F multiboard or Rigidur h are recommended for intermittent moisture applications, including splashbacks. The tolerance on the finished tile surface quoted in BS 5385: Part 1, i.e. 3mm under a 2m straight edge with thin-bed adhesives, is such that it will reflect very accurately the standard of the background surface. Important information Two coats of Gyproc Drywall Sealer applied to the face of standard grade plasterboards, with the edges adequately protected from moisture may also be suitable to receive a tile finish. The application of Gyproc Drywall Sealer provides surface water absorption resistance only, and does not meet the performance requirements for moisture resistant grade boards as defined in BS EN 520, type H1. Waterproof sealant should be used around baths or shower trays, between the wall surface and the floor at the base of partition or wall lining, to prevent any possible moisture being absorbed by the board core. Once boards are installed, the perimeter of the wall, e.g. base, head and wall abutments, should be sealed with a waterproof sealant. Continuity of linings All partitions and wall linings should be complete. There should be no omissions to board linings, e.g. behind baths. Timber stud external walls or partitions Where tiling is specified, designers should ensure that the timber is of sufficient dimensions to give a stable base for the additional loading. The moisture resistance of the timber should be within the limits given in BS 5268: Structural use of timber - Part 2. directly onto plasterboard Before tiling commences, joints and taper recesses included within the tiling area should be filled with tile adhesive. Only boards that are dimensionally stable in changing moisture conditions, such as mr grade and Glasroc H tilebacker boards should be used when tiling onto surfaces that will be subject to occasional wetting (e.g. domestic sinks and baths). When tiling onto surfaces in high moisture areas (but are not immersed in water) e.g. communal changing rooms, showers and pool hall areas, Glasroc H tilebacker should be used. Where designs include part-tiled areas, e.g. low moisture environments, apply a layer of Thistle Bond-It when using moisture resistant variant boards prior to the board being plaster skimmed above the line of the tiles. Alternatively skim with Thistle DuraFinish on moisture resistant grade boards. Refer to C08. S02. P06 Plaster skimming onto plastered surfaces Skimming to plasterboards (including Gyproc moisture resistant boards) which are to receive tiles, is not recommended. Tiles up to 20kg/m² (including adhesive and grout) can be applied directly to Thistle finish plasters, except where the system includes a bonding agent. In this situation the total weight of tiles and plaster applied over a bonding agent is limited to 20kg/m², therefore consideration should be given to tiling directly to the background. If plastering is to provide a background for tiles, avoid polishing the surface. Polished plaster surfaces should be roughened and a suitable primer used. Consult the tile adhesive manufacturer for guidance. Finishes C08 Perimeter and junction sealing Designers must give consideration to the precautions necessary at junctions to ensure that moisture is not allowed to penetrate or collect. Cut edges of boards must be appropriately sealed / waterproofed at abutments. Gypsum undercoats and finish coats are designed to work together to achieve full strength and therefore tiles should not be applied directly to Thistle undercoats, with the exception of Thistle DriCoat. Tiles should not be applied until the background and plaster are dry. 0115 945 6123 bgtechnical.enquiries@bpb.com C08. S04. P06

C08 Finishes design (continued) Table 4 weight limitations on plaster backgrounds Background finish Thistle plaster Bonding agent plus Thistle plaster Glasroc H tilebacker on existing timber floors Total weight supported 20kg/m² including adhesive, grout and tiles 20kg/m² including plaster, adhesive, grout and tiles Glasroc H tilebacker is designed as a tiling substrate for use on an existing timber floor, it is not suitable as a walking surface and is not a structural flooring grade board. On existing timber floors ensure the floor is structurally sound and is not subject to excessive movement or flexing as this could cause a tiled floor to crack. Place a bed of tile adhesive directly onto the floor surface. Bed the board into the tile adhesive to create a level surface. Make sure the yellow pre-primed finish faces outwards for tiling. Boards are fixed through to timber sub floor using British Gypsum Drywall Screws at 200mm centres. The length of fixing used should be selected to avoid penetrating through the floor surface into the cavity to prevent damage to any services that may be within the floor cavity. Scan the image with this frame for more information and videos related to this system Or visit gyp.sm/b/lk C08. S04. P07 british-gypsum.com

components Board products ( Refer to section C10. S03. P02 for details) Glasroc H tilebacker Non-combustible glass-reinforced gypsum board with a water resistant pre-primed acrylic coating to receive tiling. Gyproc FireLine mr Plasterboard with additional additives to increase fire and moisture performance. Gyproc SoundBloc rapid Gypsum plasterboard in narrow width with a high density core for enhanced sound insulation performance. Gyproc SoundBloc rapid mr Gypsum plasterboard in narrow width with moisture resistant additives and a high density core for enhanced sound insulation performance. Gyproc SoundBloc mr Gypsum plasterboard with moisture resistant additives and a high density core for enhanced sound insulation performance. Fixing products ( Refer to section C10. S04. P02 for details) Nailable Plugs Secondary mechanical fixing for Gyproc laminates in the DriLyner tl, si and rf systems on masonry walls and for increased stability when tiling. Plasterboard accessories ( Refer to section C10. S05. P02 for details) Gyproc Drywall Sealer A specially formulated sealer providing vapour control and a superior finish. Suitable for decoration with most paints and wall coverings. Glasroc F multiboard Non-combustible glass-reinforced gypsum board. Rigidur h Gypsum fibre board with additives for rigidity, durability and mechanical strength. Gyproc Moisture Resistant Gypsum plasterboard with moisture resistant additives in the core. Gyproc DuraLine mr Gypsum plasterboard with fire and moisture resistant additives and a high density core for enhanced sound insulation and impact resistance performance. Glasroc F firecase High performance, non-combustible glass reinforced plasterboard giving up to 120 minutes fire protection. Tiles (by others) Available in: 32kg/m 2 (maximum including adhesive and grout) Finishes C08 Waterproof tile adhesive (by others) Waterproof sealant (by others) Additional information For full installation details, refer to the British Gypsum Site Book, available to download from british-gypsum.com 0115 945 6123 bgtechnical.enquiries@bpb.com C08. S04. P08