PROCESS JBs. Easy to install & maintain Standard proven designs reduce project costs Superb corrosion resistance Wide choice of cable gland types

Similar documents
Glass Reinforced Polyester Enclosures BPG. Glass Reinforced Polyester Enclosures

Field case for temperature transmitter Model TIF11

Subject: Guidance on Corrosion Assessment of Ex Equipment

Standard Bourdon tube pressure gauges EN 837-1

Stainless steel. 1.6 Stainless steel IP 69 K. Premium Panel, protection category IP 69K

PRODUCTS AND SYSTEMS FOR ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

- Zone 1, 2, 21, 22 - Aluminium enclosures - Choice of 18 sizes - IP66 - IK10 ED.2017

Glycerine filled Bourdon tube pressure gauges EN 837-1

SECTION (Master Template Final-05) ELECTRICAL BOXES. A. Provide boxes for electrical equipment and wiring devices as follows:

Mounted Enclosures Steel Powder-Coated

BOXES - CONSUMER UNITS

CVB-EX Mil-C-5015 reverse bayonet ATEX Connectors

Thermocouple Heads. MOST POPULAR MODELS HIGHLIGHTED! To Order (Specify Model No.) B-9 76 (3) Model Price Material Type Number Each 48 (1 7 8)

Bulletin 800F Plastic and Metal Operators 22.5 mm mounting hole IP65/66, Type 4/4X/13 Internationally rated operators

Certificate of Compliance

Phone: +49 (0) 231 / Fax: +49 (0) 231 / Spring hinges. Art.: 6164 Art.

IP-5(Dust-Solid Particles) 5(Liquid-Water Oil)

Ensto Industrial Solutions. Enclosing solutions. for the solar energy industry

IP-5(Dust-Solid Particles) 5(Liquid-Water Oil)

Protect people and preserve equipment. Universal Enclosures

OptiLine 70. Service Poles. Technical and Material data

ARGENTA PLUS (FSC) IP55-IP65 steel floorstanding. cabinets. SEMI-COMPACT (FSC) Technical Specifications

RN Optical Termination Panel (RN OTP)

ALUBOX Series Junction boxes in IP66 aluminium alloy

Hazardous Location Cable Glands for Non-Armored Cable (Ex d/e/tb)

Certificate of Compliance

HLX300Ex-HT. Humidity/Temperature Transmitter for Intrinsically Safe Applications. Typical Applications. Features

Model KMF 115 Constant climate chambers with expanded temperature / humidity range

Multigates made of ShieldLine Materials

Thermocouples Straight Design Model TC501, for Flue Gas Measurement

Electrical Metallic Tubing (EMT) Fittings

INDUSTRIAL AND OUTDOOR ENCLOSURES Tough. Flexible. Safe.

Temperature class T4, T5 or T6 (dependent on internal components / T amb )

Differential pressure

Magnetic float switch For vertical installation Model FLS for nuclear power plants

SEISMIC PROTECTION SYSTEMS Bracing Products for Racks & Cabinets

CONFORMITY AND APPROVAL

HS h e n EU omplia t 2002 / 9 5 / C

Cable junction boxes with intrinsic fire resistance and insulation integrity

Mechanical Ratings. Description Plastic (800EP/ES) Metal (800EM/EB) 1/2 cycle sine wave for 11 ms and no damage at 100 G

LEADING IN WELDING SAFETY CATALOGUE 2014 CONSTRUCTION. Version 14/01

IP 66 TECHNICAL DATA SHEET ART. S FOCUS

MXBS SOCKET-OUTLET COMBINATION BOXES 63 A TECHNICAL FEATURES

Technical Datasheet. Compact Series Pressure Switch Models: CS2 & CS4. Compact Series. Key Features. Series Overview. Product applications

Heating Cables DATASHEET

STANDARD TECHNICAL SPECIFICATION FOR ROTAMETER VOLUME - IIB. SPECIFICATION No: PE-SS I010

EE300Ex-HT. Humidity/Temperature Transmitter for Intrinsically Safe Applications. Typical Applications. Features

Certificate of Compliance

Standard program overview fire doors

XMP i. Precision Pressure Transmitter for the Process Industry with HART -Communication. Stainless Steel Sensor

EE300Ex-HT. Humidity/Temperature Transmitter for Intrinsically Safe Applications. Typical Applications. Features

Plastic tube flowmeters Series PT/PS Variable area flowmeter for liquids and gases

Bulletin 800F Plastic and Metal Operators 22.5 mm mounting hole IP65/66, Type 4/4X/13 Internationally rated operators

XMP i. Precision Pressure Transmitter for the Process Industry with HART -Communication. Stainless Steel Sensor

ELECTRONIC EARTHING EQUIPMENT SERIES GRD 4200

EXBLT Series for Harsh and Hazardous Environments

Box sealing system DS 90

Our expertise your benefit. AE Available off the shelf.

Diaphragm pressure gauge

D-SUBMINIATURE DESCRIPTION/APPLICATION DESIGN ADVANTAGES D-SUB INDEX. IDC Systems D-Subminiature

SPECIFICATION SHEET JUNCTION BOXES

Access Wallbox Cabinet System

Combi climate glands. Product information 06/2009

EasyTrack 3 Accessories List

Guide for selecting the right FIBOX enclosure

1. GENERAL INFORMATION CAUTIONS AND GENERAL NORMS DESCRIPTION AND INTENDED USE MARKING OF DTW WEIGHBRIDGES...

Technology Aluminium-IMS-PCBs Rev For latest information please visit

Underground Dry Utilities Civil Engineering 2014 Edition

Scepter PVC Molded Junction Boxes

SECTION FIELD PANELS

JUNCTION BOX AND BAYMARSHALLING KIOSK

CONDUIT ACCESSORIES AND FIXINGS

Unflanged Junction or Pull Boxes

ERK Series. features: options: specifications: enclosure. what great systems are built on.

Thermal Solutions Worldwide SECTION C. Industrial Thermocouples and RTDs. Straight Thermocouples Assemblies with Metal Protection Tubes C-5

Thermocouple for Flue Gas Temperature Measurements,

Allen-Bradley 800FP-POT5

Thermocouple temperature sensor omnigrad T -TSC 310

Insulated enclosure, +knockouts, RAL7032, HxWxD=500x375x225mm

High Temperature Pressure Sensor

TRICOR. TRICOR Series. Technical Datasheet. Mass Flow Meters MISURATORE MASSICO - CORIOLIS MASS FLOW METER CORIOLIS TECHNOLOGY

SolarStyl BIPV New Building Integrated Photovoltaic System August V13 Page 0

2/2 % ) Direct Acting Subminiature Solenoid Valves. 1/8" and 1/4" NPT. Features. Construction. Electrical

FN04. Liquid level sensor with continuous detection. Level Measurement and Monitoring

ENGLISH. Datasheet. RS single element: Single 4 wire element, allowing connection to any Pt100 2, 3 or 4 wire instrument

SPECIFICATION OPTICAL TERMINATION BOX for FTTx

Product Datasheet. Fire Hose Reel (Page 3)

Model FD 115 Drying and heating chambers Avantgarde.Line with forced convection

CABLE TERMINALS CABLE TERMINALS

TERMS OF REFERENCE. Supply and Delivery of Prefabricated Wind Noise Reduction Systems (WNRS) and Equipment Vaults

Installation Boxes. Multifix Air. Setting a new standard in energy efficiency

THERMOWELL ASSEMBLIES & THERMOWELLS INDEX

These conditions must be maintained during transport to the laboratory.

PRESSURE SWITCHES D-LT Electro-mechanical pneumatic pressure switches. 18D-LT x2 Electro-mechanical pneumatic pressure switches.

Electrical Metallic Tubing (EMT) Fittings

PUSH BUTTONS A 1 E C 1 SERIES 5A AGENCY APPROVALS SPECIFICATIONS

Ex d. Cooling fins. 4 Joule shock resistant borosilicate glass globe Internal connection terminal box. Stainless steel protective guard A.14 ED.

Better by being quick to translate market trends into products. In this way, our innovative strength helps you to secure competitive advantages.

56-SDMS-01 REV. 01 SPECIFICATIONS FOR

Transcription:

Process Junction Boxes for fieldbus installations Relcom PROCSS JBs asy to install & maintain Standard proven designs reduce project costs Superb corrosion resistance Wide choice of cable gland types All glanding holes are located in the base of the enclosure Generous space for cable terminations Strong, high impact resistance, durable MTL Process JBs are designed for mounting Megablock fieldbus wiring components, terminators, 0 spur connections and P- surge protection devices, in order to meet the exacting requirements of process industry customers. Relcom wiring components have been chosen to connect over 0,000 fieldbus devices on hundreds of projects. With that experience, MTL/ Relcom have learned a lot about fieldbus junction box requirements for harsh environments. Process JBs make it easy to install and maintain the fieldbus system. or example, a minimum of mm (") of clearance is provided for fieldbus cable connections. This ensures that the correct bend radius is maintained when connecting to the full range of MTL/Relcom wiring components. They are available in a choice of materials and finishes that provide strength, durability and corrosion resistance to many chemicals and their vapours. The CS-000 enclosures are manufactured from stainless steel to provide the highest level of corrosion protection. The CS-000 adopt a lower cost solution, by being constructed from 0 stainless steel but with a painted finish that denies most corrosion attacks. The CS-000 enclosures are manufactured from carbonloaded, polyester which combines strength with the highest level of corrosion resistance. A wide choice of glands is available, ready fitted to the junction box: stainless steel, nickel-plated brass and plastic, enabling a high quality seal with standard or wire-armoured cables. All glanding is in the base of the enclosure with a minimum of mm of clearance between the base of the enclosure and other components. This makes glanding much easier, especially when terminating armoured cable. Significant cost savings can be made on a fieldbus project by selecting standard, and proven, fieldbus junction box designs. It eliminates the need for custom designs when choosing junction boxes for fieldbus applications and saves the cost of managing the specification and the eventual procurement of the junction boxes. To select the Process JB appropriate to your application; first decide on the enclosure material, based upon site conditions, required strength, durability and economics; this will define which series you require. Next, determine the number of fieldbus device connections, and hence the number of spur connections required in the junction box. This will also define which Megablocks (and maybe terminators) are required. Use the application examples to help you. Identify any additional items that will need to be housed in the enclosure, e.g. surge protection devices, additional terminators. Calculate how much they will require. Add this to length of the Megablock(s) and choose an enclosure with sufficient rail length. inally, decide on gland type. Is the cable armoured? Does the environment require steel or brass glands, or will plastic be sufficient? See application example tables and ordering information for details on how to fully specify the enclosure in your order. UROP (MA) Tel: + (0) ax: + (0) AMRICAS Tel: + 0 000 ax: + 0 ASIA PACIIC Tel: + ax: + -mail: enquiry@mtl-inst.com Web site: www.mtl-inst.com Oct 00

CS-000 Series junction boxes The CS-000 Series enclosures are manufactured from 0 stainless steel with a RAL0 painted finish, to provide high levels of corrosion resistance for process environments. The CS-xx Process JBs are suitable for Zone and Zone intrinsically safe (x i) and increased safety applications (x e). The junction boxes are available pre-drilled for one segment: having trunk-in, trunk-out and spur connections; or a trunk-in and 0 or spur connections; or two segments having a trunk-in and 0 or spur connections. Two-pair multicore trunk cable may be used when only a single trunk gland is available. The wide choice of glands, including stainless steel, nickel-plated brass and plastic, enables a high quality seal with standard or wire armoured cables. The box incorporates a rain channel that prevents standing water from damaging the one-piece seal; diverting it away from the contents when the door is opened. A 0mm earth stud and a breather are also included as standard. An adhesive backed, Traffolyte tag label is supplied loose or can be engraved with the tag number and fitted, if details are supplied when ordering. SPCIICATION GNRAL Materials 0 stainless steel - painted (RAL 0 grey) Chloroprene gasket CS-0, CS-0, CS-: - one () CS-0, CS-: - two () s to N 00 x. T section, mounted vertically ach rail fitted with two end stops eather plug Provided xternal earth connection M0 threaded stud Tag label Traffolyte, adhesive backed - white background - black text Other Hinged lid NVIRONMNTAL Operating Temperature C to +0 C - Steel & nickel plated brass glands 0 C to +0 C - Plastic glands Storage Temperature C to + C Relative Humidity % RH (non-condensing) to % IP rating IP to N 0 Impact resistance Nm to N 00 Location of Process JB Safe area, Zone, IIC T hazardous area or Zone, IIC T hazardous area for intrinsically safe fieldbus segment. Note: If used in a hazardous area, the contents must be suitably certified/approved. APPLICATION XAMPLS Model Max. glands length mm Megablocks /trunk No of trunks Spurs/ trunk Trunk in Trunk out Total spurs -ZZ* value Unused DIN rail length mm Single trunk applications CS-0 way 0 way 0 way(t) - 0 CS-0 way + way 0 way 0 way(t) 0 0 way(t) 0-0 0 - CS- way(t) - CS-0 x way + way(t) - x Double trunk applications CS-0 x x way(t) (-pair multicore) - x x 0 way(t) 0 (-pair multicore) - 0 0 x CS- x x way(t) (-pair multicore) - x (T) = Megablock with integral terminator * see ordering information UROP (MA) Tel: + (0) ax: + (0) AMRICAS Tel: + 0 000 ax: + 0 ASIA PACIIC Tel: + ax: + -mail: enquiry@mtl-inst.com Web site: www.mtl-inst.com Oct 00

NCLOSUR AND MOUNTING DIMNSIONS A C X Product label X Rain Channel Part Section X-X (nlarged scale) x Ø MTL B Door D M0 arth Stud Body XXXXXXXX Water or Ice Seal View with lid removed Tagging label Area for mounting fieldbus components A B C D Weight CS-0 00 00N/A.0-.kg CS-0 0 0 0 0 N/A.0 -.0kg CS- 0 0 0 0 N/A.0 -.kg CS-0 0 0 0 0 0.0 -.kg CS- 0 0 0 0 0.0 -.kg Dimensions in mm GLANDING ARRANGMNTS CS0 CS0 0 CS0 CS 0 0 0 CS = Recommended Trunk Position = IP xe eather 0 All gland holes drilled M0 T section x. to N 00 = Distance between centres 0 UROP (MA) Tel: + (0) ax: + (0) AMRICAS Tel: + 0 000 ax: + 0 ASIA PACIIC Tel: + ax: + -mail: enquiry@mtl-inst.com Web site: www.mtl-inst.com Oct 00

CS-000 Series junction boxes The CS-000 Series carbon loaded polyester enclosures provide the highest levels of corrosion resistance for the harshest process environments. The CS-xx Process JBs are suitable for Zone and Zone intrinsically safe (x i) and increased safety applications. The controlled surface resistance eliminates the risk of static buildup. The junction boxes are available pre-drilled for one segment: having trunk-in, trunk-out and spur connections; or a trunk-in and 0 or spur connections; or two segments having a trunk-in and 0 or spur connections. Two-pair multicore trunk cable may be used when only a single trunk gland is available. A wide choice of glands, including stainless steel, nickel-plated brass and plastic, enables a high quality seal to be achieved with either standard or wire-armoured cables. The mounting screws are insulated by the case material and are located outside of the lid seal. A 0mm earth stud and a breather are included as standard. An adhesive backed, Traffolyte tag label is supplied loose or can be engraved with the tag number and fitted, if details are supplied when ordering. SPCIICATION GNRAL Materials Carbon-loaded, glass-fibre reinforced polyester, halogen-free, surface resistance < 0 Ω to N 00 Stainless steel lid screws, silicone lid seal CS-0, CS-0, CS-: - one () CS-0, CS-: - two () s to N 00 x. T section, mounted vertically ach rail fitted with two end stops eather plug Provided xternal earth connection M0 threaded stud Tag label Traffolyte, adhesive backed - white background - black text NVIRONMNTAL Operating Temperature C to +0 C - Steel & nickel plated brass glands 0 C to +0 C - Plastic glands Storage Temperature C to + C Relative Humidity % RH (non-condensing) to % IP rating IP to N 0 Impact resistance Nm to N 00 Location of Process JB Safe area, Zone, IIC T hazardous area or Zone, IIC T hazardous area for intrinsically safe fieldbus segment. Note: If used in a hazardous area, the contents must be suitably certified/approved. APPLICATION XAMPLS Model Max. glands length mm Megablocks /trunk No of trunks Spurs/ trunk Trunk in Trunk out Total spurs -ZZ* value Unused DIN rail length mm Single trunk applications CS-0 way 0 0 way 0 way(t) - 0 CS-0 way + way 0 way 0 way(t) 0 0 way(t) 0-0 0 - CS- 0 way(t) - CS-0 x 0 way + way(t) - x Double trunk applications CS-0 x 0 x way(t) (-pair multicore) - x x 0 way(t) 0 (-pair multicore) - 0 0 x CS- x 0 x way(t) (-pair multicore) - x (T) = Megablock with integral terminator * see ordering information UROP (MA) Tel: + (0) ax: + (0) AMRICAS Tel: + 0 000 ax: + 0 ASIA PACIIC Tel: + ax: + -mail: enquiry@mtl-inst.com Web site: www.mtl-inst.com Oct 00

NCLOSUR AND MOUNTING DIMNSIONS A Product label x Ø. C MTL B D XXXXXXXX Tagging label Area for mounting fieldbus components View with lid removed A B C D Weight CS-0. 00. N/A. -.0kg CS-0. 00. N/A. -.kg CS- 0. 0 0. 0 N/A.0 -.kg CS-0 0 0. 0.0 -.kg CS- 0 0. 0.0 -.kg GLANDING ARRANGMNTS CS0 CS0 0 CS CS0 0 0 0 CS = Recommended Trunk Position = IP xe eather 0 0 All gland holes drilled M0 T section x. to N 00 = Distance between centres The glands shown are representative only UROP (MA) Tel: + (0) ax: + (0) AMRICAS Tel: + 0 000 ax: + 0 ASIA PACIIC Tel: + ax: + -mail: enquiry@mtl-inst.com Web site: www.mtl-inst.com Oct 00

CS-000 Series junction boxes The CS-000 Series enclosures are manufactured from polished stainless steel to provide the highest levels of corrosion resistance for the harshest process environments. The CS-xx Process JBs are suitable for Zone and Zone intrinsically safe (x i) and increased safety applications. The junction boxes are available pre-drilled for one segment: having trunk-in, trunk-out and spur connections; or a trunk-in and 0 or spur connections; or two segments having a trunk-in and spur connections. Two-pair multicore trunk cable may be used when only a single trunk gland is available. The wide choice of glands, including stainless steel, nickel-plated brass and plastic, enables a high quality seal with standard or wire armoured cables. The box incorporates a rain channel that prevents standing water from damaging the one-piece seal; diverting it away from the contents when the door is opened. A 0mm earth stud and a breather are also included as standard. An adhesive backed, Traffolyte tag label is supplied loose or can be engraved with the tag number and fitted, if details are supplied when ordering. SPCIICATIONS GNRAL Materials lectrochemically polished Stainless Steel Chloroprene gasket CS-0, CS-0, CS-: - one () CS-: - two () s to N 00 x. T section, mounted vertically ach rail fitted with two end stops eather plug Provided xternal earth connection M0 threaded stud Tag label Traffolyte, adhesive backed - white background - black text Other Hinged lid NVIRONMNTAL Operating Temperature C to +0 C - Steel & nickel-plated brass glands 0 C to +0 C - Plastic glands Storage Temperature C to + C Relative Humidity % RH (non-condensing) to % IP rating IP to N 0 Impact resistance Nm to N 00 Location of Process JB Safe area, Zone, IIC T hazardous area or Zone, IIC T hazardous area for intrinsically safe fieldbus segment. Note: If used in a hazardous area, the contents must be suitably certified/approved. APPLICATION XAMPLS Model Max. glands length mm Megablocks /trunk No of trunks Spurs/ trunk Trunk in Trunk out Total spurs -ZZ* value Unused DIN rail length mm Single trunk applications CS-0 way 0 way 0 way(t) - 0 CS-0 way + way 0 way 0 way(t) 0 0 way(t) 0-0 0 - CS- way(t) - - CS- x way + way(t) - x Double trunk applications CS- x x way(t) (-pair multicore) - x x 0 way(t) 0 (-pair multicore) - 0 0 x CS- x x way(t) (-pair multicore) - x (T) = Megablock with integral terminator * see ordering information UROP (MA) Tel: + (0) ax: + (0) AMRICAS Tel: + 0 000 ax: + 0 ASIA PACIIC Tel: + ax: + -mail: enquiry@mtl-inst.com Web site: www.mtl-inst.com Oct 00

NCLOSUR AND MOUNTING DIMNSIONS A C X Product label X Rain Channel Part Section X-X (nlarged scale) x Ø MTL B Door D M0 arth Stud Body XXXXXXXX Water or Ice Seal View with lid removed Tagging label Area for mounting fieldbus components A B C D Weight CS-0 00 00N/A.0-.kg CS-0 0 0 0 0 N/A.0 -.0kg CS- 0 0 0 0 N/A.0 -.kg CS- 0 0 0 0 0 0.0 -.kg GLANDING ARRANGMNTS CS-0 CS-0 0 CS- CS- 0 0 0 = Recommended Trunk Position = IP xe eather All gland holes drilled M0 T section x. to N 00 = Distance between centres UROP (MA) Tel: + (0) ax: + (0) AMRICAS Tel: + 0 000 ax: + 0 ASIA PACIIC Tel: + ax: + -mail: enquiry@mtl-inst.com Web site: www.mtl-inst.com Oct 00

APPROVALS Region urope N America Authority Kema UL Standard N 00: + pra UL0 UL0 th edition N 00: + pra C. No-M C. No N 0-: IC -0 Amendments + IC- 0 Approved for II G x e II Nema X for Class I, Zone II D Class I Div Ax e II, x e II MTL Part No. Crouse Hinds nclosure Part Number Certificate Numbers CS-0 NXT Kema ATXU 0 CS-0 NXT Kema ATXU 0 CS- NXT00 Kema ATXU pending CS-0 NXT0 Kema ATXU pending CS- NXT0 Kema ATXU pending CS-0 NXT Kema ATXU 0 CS-0 NXT Kema ATXU 0 CS- NXT00 Kema ATXU pending CS- NXT0 Kema ATXU pending Region urope N America Authority PTB UL Standard N 00: +A+A UL0 N 00: Approved for II G x e II Nema X for II D Class I Div MTL Part No. Bartec nclosure Part Number Certificate Numbers CS-0 0--/0 PTB 0ATX0U CS-0 0--/0 PTB 0ATX0U CS- 0--00/0 PTB 0ATX0U CS-0 0--00/0 PTB 0ATX0U CS- 0--00/0 PTB 0ATX0U GLAND OPTION DTAILS Option Description Gland model no. Cable Size mm Socket size mm Temp. range -A0 Nickel plated brass gland, for steel wired armoured cable M0 x d/e double seal -R0 Stainless steel gland, for steel wired armoured cable M0 x d/e double seal -S0 Stainless steel gland, M0, x e, single seal -C0 Nickel plated brass gland, M0, x e, single seal -P0 Black nylon gland M0, x e, single sea Capri AD..0 outer diam..0.0 inner diam. 0. armour 0 to +0 C Capri AD..0 outer diam. 0 to +0 C.0.0 inner diam. 0. armour Capri AD.0.0 outer diam. / 0 to +0 C Capri AD.0.0 outer diam. / 0 to +0 C Jakob 0.0 PASWL/X..0 outer diam. 0 to +0 C ORDRING INORMATION Part No CS-XX-YYY-ZZ CS-XX-YYY-ZZ CS-XX-YYY-ZZ Description Process JB, 0 steel, stainless, painted Process JB, carbon loaded GRP Process JB, steel, stainless XX = number of spur outlets 0 spur outlets + trunk-in and trunk-out 0 or 0 or spur outlets + trunk-in 0 or 0* or spur outlets + trunk-in -YYY = trunk & spur glanding -00 = Predrilled for M0 glands - none fitted -X0 = Predrilled, with M0 brass blanking plugs -Y0 = Predrilled, with M0 plastic blanking plugs -A0 = Nickel-plated brass M0 glands for wire-armoured cable -R0 = Stainless Steel M0 glands for wire-armoured cable -S0 = Stainless Steel M0 glands -C0 = Nickel-plated brass M0 glands -P0 = Plastic M0 glands * 0 spur outlet version not available for CS-xx series. Use CS--yyy-0 -ZZ = number of spur outlet glands to be fitted A gland of the specified type is always supplied and fitted for the trunk-in. Any remaining holes are fitted with blanking plugs of the same material as the glands. If this number is not specified, glands will be fitted to all outlets (including the trunk-out, if applicable). xample part number CS-0-A0-0 An CS-0 junction box having spur outlets, trunk-in and trunk-out. Supplied with nickel-plated brass M0 glands for wire-armoured cable fitted on spur outlets + trunk-in. The trunk-out has a nickel-plated blanking plug fitted. ACCSSORIS Surface mounting kit CS-000-CGT Cable gland tool Labels for Hazardous Area applications CS-LAB-NA-NA x na trunk and Spurs (pack of 0) CS-LAB-NA-NL x na trunk with x nl spurs (pack of 0) CS-LAB-NL-NL x nl trunk and Spurs (pack of 0) CS-LAB-IS-IS x i trunk and spurs (pack of 0) UROP (MA) Tel: + (0) ax: + (0) AMRICAS Tel: + 0 000 ax: + 0 ASIA PACIIC Tel: + ax: + -mail: enquiry@mtl-inst.com Web site: www.mtl-inst.com Oct 00