Centralisation of Endoscope Decontamination. Aisling Bonner Manager HSDU Altnagelvin Hospital

Similar documents
ONLY VALID FOR JAG ACCREDITATION IN PDF FORMAT

ENDOSCOPE DECONTAMINATION- EDUCATION AND TRAINING COMPETENCY FRAMEWORK

National Endoscopy Programme. Decontamination Standards for Flexible Endoscopes

Christina Bradley Endoscope Decontamination A Webber Training Teleclass. Christina Bradley

Critical aspects of endoscope decontamination-an overview of endoscope decontamination training for both engineers and users.

FREQUENTLY ASKED QUESTIONS FOR THE ADVANTAGE

SERIE 4. rapid, reliable, efficient

CISA Reprocessing Systems

Endoscopy Reprocessing Trends. Wayne Spencer United Kingdom

SERIE 4. rapid, reliable, efficient

TOTAL SOLUTION FOR ENDOSCOPE REPROCESSING

POLICY FOR THE DECONTAMINATION OF FLEXIBLE ENDOSCOPES

ADVANTAGE PLUS Pass-Thru

Endoscope Decontamination. A Tube in a Hole??

Endoscope Reprocessing: Guidance on the Requirements for Decontamination Equipment, Facilities and Management.

SERIE 3. Everything has changed... but the best

Ethicon, Inc All rights reserved. EVOTECH and the EVOTECH logo are registered trademarks owned by Advanced Sterilization Products.

SERIE ENT. the fastest reprocessor designed for small endoscopes

Manner of Assessment Code (check all that apply) & Surveyor Notes. Yes N/A. Yes. Yes N/A N/A. Yes N/A. N/A Yes N/A

Choice Framework for local Policy and Procedures Decontamination of flexible endoscopes: Operational management manual Version:1.

GETINGE 8666/8668 WASHER-DISINFECTOR. Always with you

35.0 Sterile Supply Unit (SSU)

John van Bergen Henegouw. Monitoring the Performance of your Automated Endoscope Reprocessor. Validation

Best Practices for Reprocessing Endoscopes

Health Service Executive Standards and Recommended Practices for Commissioning, Validation and Testing in Endoscope Decontamination Facilities

WASSENBURG DRY320. Drying and storage cabinet A revolution in ergonomics

ROP SELF ASSESSMENT AND ACTION PLAN ACCREDITATION CANADA

SERIE TEE. automatic reprocessor for TEE probes

SUBJECT: Detection of Blood residue inside the biopsy channel of a scope

ADVANTAGE PLUS Pass-Thru Endoscope Reprocessing System

Sterile Services and Theatres Working in Harmony

WASSENBURG WD440 PT. Pass through endoscope washer-disinfector Optimum safety in workflow

Medical Device Reprocessing Assessment - General (Cleaning, Disinfection, and/or Sterilization)

ADVANTAGE PLUS Pass-Thru Endoscope Reprocessing System

T-DOC EndoSolutions Manage your Endoscope workflow

GETINGE FD1600 FRONT LOADED FLUSHER-DISINFECTOR. Always with you

The Decontamination, Storage and Use of Flexible and Rigid Endoscopes

Low Temperature Processing. An Update on Guidelines, Standards and Requirements

Partnership. Hospital Sterilizers. T-Max Line

Facility: Audit Date Auditor Name/s

WASSENBURG WD440. Toploader endoscope washer-disinfector Optimum process assurance

Decontamination of Flexible Endoscopes Procedure

Innova. New E2/E3 Series. Safe Reprocessing of Flexible and Rigid Endoscopes

DSC8000. store, dry & protect your endoscope for patient safety

WASSENBURG WD440. Toploader endoscope washer-disinfector Optimum process assurance

ENDOSCOPIC REPROCESSING ETD DOUBLE Advancing the Efficiency of Reprocessing.

BIOTECH-GERMANDE ENDOSCOPE REPROCESSING WITH BRUSHLESS CLEANING PROCESS CONDITIONS. Lionel PINEAU PhD

Testing the Endoscope Journey vs the Decontamination Process. Wayne Spencer

PROVEN IN THE FIGHT AGAINST

T-Max Hospital Autoclaves. For CSSDs, OR and Medical Centers. T-Max Line

GROUP. Water Purification Solutions for Healthcare Providers

Getinge Automation System for washer-disinfectors

Uniclean PL II 10 Premium Line

Australasian Health Facility Guidelines. Part B - Health Facility Briefing and Planning Sterilizing Services Unit

Ideal Sterilization Method. Sterilization. Sterilization Practices in Healthcare Facilities

Cross Infection Control

Standards of Infection Prevention in Reprocessing Flexible Gastrointestinal Endoscopes Webinar FAQ

WHTM Decontamination of flexible endoscopes. Part A: Policy and management. Welsh Health Technical Memorandum

MDRAO Importance of Bedside & Manual Precleaning CONMED.CA

Overview: High Level Disinfection

ENDOSCOPE REPROCESSING AND INFECTION CONTROL FOR ENDOSCOPY

SUBJECT: Detection of Blood (hemoglobin) residue inside the biopsy channel of an endoendoscope

TRAINING PROGRAMME INTRODUCTION:

MDRAO ONLINE COURSE FOURTH EDITION 2018

Decontamination of Reusable Medical Devices: A Risk Management Perspective. By Paul Holland

TRACECARE Monitoring, Reporting & Traceability Solutions

The Human Touches in Endoscope Infection

The purpose of this DOPs form is to provide a universal training and assessment tool for continuity when training in manual cleaning processes.

Quality AS/NZS4187:2014 ROBYN WILLIAMS NUM CSSD LBHN CHAIR OF STANDARDS AUSTRALIA HE-023 RESPONSIBLE FOR AS/NZS 4187

Thermo Scientific HyClone WFI Quality Water. Ultra pure to meet today s rapid manufacturing advances

Place and Role of Disinfection and Sterilization in Health Care Systems

Getinge da Vinci Solution

pump pressure conveying quantity chamber geometry flow conditions Washing arms trays water quantity dosing temperature foam performance

Low temperature sterilizer Getinge STERIZONE VP4

Appendix 2. Revised 510(k) Summary

AMSCO 600 STEAM STERILIZERS QUALITY, PERFORMANCE AND RELIABILITY. Premium sterilization for today s CSSD. Central Sterile Services

AUTOMATED ENDOSCOPE REPROCESSOR. OER-Pro Easy. Fast. Reliable.

Partnership. Hospital Sterilizers. T-Max Line

5 Updates to Flexible Endoscope Reprocessing

INTEGRATED VPHP DECONTAMINATION SYSTEMS THE EMERGING UTILITY

Plasma Low Temperature Sterilization. With vaporized hydrogen peroxide. PlazMax Line

Steam sterilizing autoclaves CSSD range

Is contamination of bronchoscopes really a problem?

Safe to Handle? Comparing Manually and Machine-Washed Medical Devices

Guard by TSSU. October 4,2009

BSL3 and BSL4 Autoclaves. Laboratory Line

ANNEX 5 MANUFACTURE OF IMMUNOLOGICAL VETERINARY MEDICINAL PRODUCTS

Health Service Executive Code of Practice for Decontamination of Reusable Invasive Medical Devices

REPROCESSING AND DOCUMENTATION CDS System Approach and ENDOALPHA.

Cidex Plus 28 Day Solution Instructions For Use

Flexible Endoscopes: The A,B,C s of Monitoring Manual Cleaning Efficacy!

SITE MASTER FILE For MHRA

Pharmaceutical Compounding Sterile and Nonsterile Preparations. Jeanne Sun, PharmD

QUALITY ASSURANCE IN AN MDRD

Local Decontamination Units: Guidance on the Requirements for Equipment, Facilities and Management

Getinge HS55 Hospital sterilizer

Getinge HS44 sterilizer for high capacity at point of use

Recommendations for Physical Space for Decontamination Areas

Response Schedule 2 Decontamination: Multichamber Washer Disinfector of 12.

Transcription:

Centralisation of Endoscope Decontamination Aisling Bonner Manager HSDU Altnagelvin Hospital

Endoscope Decontamination WHY? To prevent infection from patient to patient. To make equipment safer to handle. To prolong the life of the equipment which is very expensive. To protect the quality of diagnostic samples.

Centralisation WHY? Provide a quality process that is consistent, controlled and validated Patient safety Dedicated trained staff Improve working environment Update equipment Cost efficiency

Endoscopy Decontamination Pre-Centralisation Service fragmented Physical environment unsuitable AER s and water did not meet HTM standards Inconsistent staff training Inadequate traceability No quality control

The Team Manufacturer of the AER s Health Estates Test Person (Sterilizers) Infection Control & Microbiologist Authorized Person [Sterilizers] Sterile Services The User Contractors Testing/building Estates Management Planning Servicing/repair

Guidelines MDA DB2002(05) Decontamination of Endoscopes July 2002 HTM 2030 BSG Guidelines For Decontamination of Equipment for Gastrointestinal Endoscopy October 2003 EN/ISO 15883 part 4 Requirements and Tests for WD s Employing Chemical Disinfection for Thermo-labile Endoscopes 2005 NHS Model specification C32 - Automated Endoscope Reprocessors for Flexible Endoscopes.

A documented quality system is needed and should be Hine Independent Review Northern Ireland March 2005 Decontamination areas must be large enough to accommodate centralisation and ensure a dirty in clean out cycle Automated Endoscope Reprocessors must be validated and tested in accordance with HTM 2030 Water used in AER s should be HTM 2030standard Decontamination must be carried out by personnel who have been appropriately trained All decontamination units must have a traceability system capable of tracing all scopes to the point of use on patient

Endoscopy Service Confusion What machines do we buy? What model and design? Will they comply with the standards? Where do we locate the machines? What testing is needed? What disinfectant can we use? Is it compatible with our scopes? What standard of water do we need? How many scopes will we need? How do we perform traceability Too many questions and not enough answers!!!

Do You Feel Like This? Or This

Tenders Building including worktops and finishes AER s pass through Dryers vertical or diagonal storage Sinks height adjustable Hatches pass through and interlocking Traceability Trace all stages of the decontamination process to the patient

Options for Location Renovate within the footplate of the existing endoscopy suite Relocate the service to HSDU Create a unit elsewhere within the Hospital building Build a new unit somewhere on the hospital site Outsource the service completely Expand the existing facility

Guidelines HBN 52 part 2 - Accommodation for Day Care Endoscopy Unit 1994 needs revised HBN 13 - Sterile Service Departments 2004

The Future Endoscopy Department dirty corridor Staff room Treatment room Returns and wash Treatment room Clean process Treatment room Patient ward/waiting area Office Storage clean corridor

What type of AER?

AER Requirements Self disinfection cycle available Printer and chart recorders fitted Single chamber or double Pass through with printout Channel patency monitoring. Interlocked doors etc. (HTM 2030, EN15883 part 4) Leak test facility Test connections for TP(S) and equipment Single shot doses of disinfectant Water requirements and standards etc How many AER s????

Independent Data Cycle number, date and time Leak test Channel patency Detergent dosage Rinse Disinfectant dosage and concentration Holding time for disinfection

Schedule of operational tests for WD sfor endoscopes Table 2e, chapter 5 details the installation tests by the contractor, and operational tests by the appointed TP(S) Testing requirements to HTM 2030 Schedule of periodic tests for WD s for endoscopy Table 5e, chapter 7 details the schedule Daily Tests User Weekly Tests User or TP(s) - Automatic control test - Water hardness/conductivity - TVC s - Cleaning efficacy Last two need to be controlled and involve microbiologist Documented procedures Quarterly Tests TP(s) Annual Tests TP(s) Audits test reports AP(s)

What Solutions? Glutaraldehyde[Cidex,Asep,Totacide} Peracetic Acid - Aperlan Chlorine Dioxide [Tristel] Superoxidised Water [Sterilox]{locations and on-costs must be considered} Cidex OPA What do we use? It must be correct for the scopes, AER and effective. It must be safe for the patient and staff handling the equipment - COSHH

Warm (30 C ) HEPA filtered air dries and circulates through each channel preventing contamination. Dryers Warm (30 C ) HEPA filtered air dries and circulates throughout the chamber in a circular movement. Microprocessor controls and alarms connected to a printer Recorded time limits on scopes Independent validation Temperature UV readings Humidity Endoscope air flow Chamber air flow Graph & printed data * Validated microbial testing

Scopes All scopes are compatible with AER s and disinfection solution Sufficient stock to accommodate a 2hr turnover Manufacturers instructions for decontamination are available and written in to procedures Tender included requirements for compatibility with AER s and supply of all attachments needed. THIS MEANT MANUFACTURERS OF SCOPES HAD TO COMMUNICATE WITH MANUFACTURER OF AER!!!

Staffing Sufficient staff to accommodate clean and dirty areas Quality controller Full time technical maintenance staff have been appointed so that all machinery is regularly tested and maintained to HTM standards. Staffing and Training Training Staff are trained in all aspects of decontamination so that they recognise if any part of the process has failed Training is in house and external Competencies are assessed and documented Procedures for each scope with details on each channel. If possible manufacturers drawings! TRAINING MUST BE CONTINUAL!!

Documentation and Traceability Traceability Operator at each stage Patient ID Manual wash Detergent used Disinfection used and expiration date Cycle number Scope and accessories Loading AER time and date Unloading AER time and date Dryer loading and unloading Issue time and date Barcode Label use by date Documentation Operational Procedures Training records AER validation and test reports Water TVC and chemical reports Dryer validation reports COSHH file Environmental Procedures Audit records ISO 13485:2003 standard

Decontamination Services Post Centralisation Dirty in/clean out environment Environmental testing and control AER s validated and tested to HTM 2030 Reverse Osmosis water quality Designated decontamination staff Competency assessed training

You never know who could be next It maybe you!!!