INTERNATIONAL CODE COUNCIL 2009/2010 CODE DEVELOPMENT CYCLE

Similar documents
ICC CODE DEVELOPMENT CYCLE TECHNICAL UPDATES TO THE 2009/2010 FINAL ACTION AGENDA TO THE INTERNATIONAL CODES

Recommended Amendments to the 2015 International Energy Conservation Code (IECC)

Success with 2009 IECC: Tech Tips for Builders. Insulation. Copyright 2014 Advanced Energy. All Rights Reserved

1. PREINSPECTION RESIDENTIAL ENERGY EFFICIENCY 7

The 2009 International Residential Code and the American Recovery and Renewal Act of 2009

INSULATION. Success with 2015 IECC Northeast & Mid-Atlantic. Techtips for Builders & Trades

Success with 2009 IECC in Georgia: Tech Tips for Builders. Insulation. Copyright 2014 Advanced Energy. All Rights Reserved

Success with 2012 NC Energy Conservation Code in North Carolina: Tech Tips for Builders. insulation

Slab edge insulation is one of

International Code Council

Building Envelope

Ontario s Building Code

INSULATION SUCCESS WITH 2012 IECC DELAWARE. for Builders & Trades. Recommended Practices for Optimized Energy Savings

RESIDENTIAL ENERGY CODE. The 2015 International Energy Conservation Code (IECC) as modified below.

Residential Energy Code Update

COMMERCIAL ENERGY EFFICIENCY

9.36. Energy Efficiency

TABLE INSULATION AND FENESTRATION REQUIREMENTS BY COMPONENT a

Plan /Submission Requirements

2009 IECC with St Louis Amendments. Fenestration U-factor Skylight U-factor Glazed fenestration SHGC NR 0.

Boulder City NV Prepared by (Print Name) Signature Date

Energy Codes and the Building Envelope

Success with Louisiana Energy Code. Techtips for Builders/Trades & Code Officials INSULATION

Thermal Bridging in Residential Construction

Changes. With respect to Energy efficiency 2006 Code is 22% better than 1997 Code Code 37% better than 1997 Code

Plan Check & Field Inspection Guide

Energy Efficiency For Housing

Feature Zone IECC 2009 IECC

A. GENERAL INFORMATION

Residential Requirements of the Texas Energy Code 2009 IRC Chap 11

APPENDIX DETAIL (1) INSULATION HAS 3-INCH TOP INSPECTION GAP AND EXTENDS 24 INCHES BELOW GRADE

2006 INTERNATIONAL ENERGY CONSERVATION CODE

Residential Energy Code Combustion Air and Make-Up Air

WASHINGTON STATE ENERGY CODE, APPENDIX CHAPTERS

Energy Efficiency For Housing

ORDINANCE NO. XXXX BE IT ORDAINED BY THE GOVERNING BODY OF THE CITY OF LAWRENCE, KANSAS:

2012 NC Building Code Table Required Separation of Occupancies. ( Item B-1)

Truss Heel Heights and Energy Code Requirements. Overview Revised 2/17/2017

IECC - RESIDENTIAL - ENERGY TAC

Development and Introduction to the 2012 North Carolina Energy Conservation Code

CHANGES TO THE US ENERGY CODES COMMERCIAL & RESIDENTIAL

Chapter 4: Insulation

2015 MICHIGAN UNIFORM ENERGY CODE Effective: February 8, 2016

N Insulation tradeoff. The insulation requirements in Table shall be permitted as a tradeoff for the specified improvement.

1. The 2018 NCECC shall regulate the design and construction of buildings for the effective use of.

Residential Data Collection Checklist 2009 International Energy Conservation Code Climate Zone 2

City of High Point Airport Overlay District Noise Level Reduction Design Standards

Instructions for the Residential Building Data Collection Checklist 2009 International Energy Conservation Code with 2011 Georgia Amendments

1. When using the REScheck software, the compliance report submitted by the permit holder shall indicate that the applicable code is.

NC 2009 Residential Code changes (Highlights on changes between the 2006 and 2009 NC Residential Code)

International Energy Code Suggested Amendments

ENERGY STAR Qualified Homes, Version 3 (Rev. 03) Inspection Checklists For National Program Requirements

Supplementary Standard SB-12. Energy Efficiency For Housing

PA Residential Code Update Overview

Standards for Jackson EMC s Right Choice Program Revised: June 2011

Supplementary Standard SB-12. Energy Efficiency For Housing

Presented by: Stephen Carr Regional Building Science Manager (386)

SB-12, Chapter 3. Applicable to all building permit applications submitted after December 23, 2016

GRAYS HARBOR COUNTY TECHNICAL ASSISTANCE BULLETIN

Spray Polyurethane Foam. Insulation and Air Barrier Requirements of the 2012 I-Codes. Spray Foam Coalition

APPROVED. Acceptable to the code official for compliance with the provisions of the applicable Code or referenced Standard.

Prescriptive Checklist for the 2015 Washington State Energy Code

2010 National Building Code Adoption and Associated Process Changes

Town of Farragut RESIDENTIAL CONSTRUCTION ENERGY EFFICIENCY. LAST UPDATE: July 03, 2014

Chapter 1: Compliance

2009 IECC Chapter 1 Additions, alterations, renovations or repairs.

1. Each of the following is a compliance path option for energy conservation code compliance for Residential Buildings except.

THE CITY OF FAYETTEVILLE ADOPTED THE 2009 INTERNATIONAL ENERGY CONSERVATION CODE (IECC) ON JULY 17, 2012

A Closer Look Inspection Service 2015 IECC Residential DFW area handout

1 Exam Prep Florida Building Code-Energy Conservation Edition Tabs and Highlights

Table 1. Insulation Type and R-Values. Avg. R-Value Per Inch (h*ft 2 *deg F/Btu*in)

PICK YOUR POISON AND HOW TO GET THERE. Presented By Robby Schwarz

GAF EnergyGuard Polyiso Wall Sheathing

Inspection of New One- and Two- Family Dwellings

Recommended Amendments to the 2012 International Residential Code (IRC)

May 21, John K. Holton was incorrectly identified as a member of voting status ( * ) when the document was approved for publication.

2012 IECC with Washington State Amendments

BUILDING CODE REQUIREMENTS

2012 INTERNATIONAL ENERGY CONSERVATION CODE ADOPTION TOOLKIT OCTOBER 2012

Attachment of Exterior Wall Coverings Through Polyiso to Wood or Steel Wall Framing

Residential Energy Code Compliance

Energy Efficiency: Designing Wood-Frame Buildings for Occupant Comfort

Where to Draw the Line with Thermal Boundaries

RESIDENTIAL ENERGY EFFICIENCY

Bridging on Building Envelope Performance. A Whole Building Energy Perspective

Deer Ridge Consulting, Inc.

2012 IECC Residential with State Adopted Changes

Insulation, Fireblocking, Draftstopping and Crawl Space Requirements REVISION DATE: JANUARY 2017

SUBJECT: NEW 2000 INTERNATIONAL RESIDENTIAL CODE (IRC) DATE:

Thermal Characteristics of Exterior Building Wall (Above Heritage Building

Project Name: Enforcement Agency: Permit Number:

Manitoba Energy Code for Buildings. Part 3 Building Envelope

Residential Plan Review for New One and Two Family Dwellings

Zero Energy Ready Home Training

R-Value and Densities Chart

Originally Issued: 03/28/2014 Revised: 05/25/2017 Valid Through: 03/31/2018

2018 IECC Residential Provisions with Corresponding IRC Sections

2015 BUILDING CODES APPENDIX Q TINY HOUSES. Routt County Regional Building Department

Understanding Energy Codes

Hawaii Amendments to the 2009 International Energy Conservation Code (IECC) January 30, 2012 version. Training Handout

Transcription:

INTENATIONAL CODE COUNCIL 09/10 CODE DEVELOPMENT CYCLE 09/10 FINAL ACTION AGENDA UPDATE #2 INTENATIONAL ENEGY CONSEVATION CODE Updated 10-22-10 October 25. 27-31, 10 CHALOTTE CONVENTION CENTE CHALOTTE, NC

EC13-09/10, Part I - Public Comment 23 Corrections to: Column - Wood Frame Wall Value i ; ows - 6, 7 and 8 EC13-09/10, Part I Public Comment 23: Mark Halverson, representing APA, requests Approval as Modified by this Public Comment. Modify the proposal as follows: CLIMATE ZONE TABLE 402.1.1 INSULATION AND FENESTATION EQUIEMENTS BY Component WOOD FAME WALL VALUE FENESTATION U-FACTO SKYLIGHT U-FACTO GLAZED FENESTATION CEILING VALUE MASS WALL FLOO VALUE SHGC VALUE k VALUE 1 N 0.75 0.30 30 13 3/4 13 0 0 0 2 0.50 i 0.65 0.30 30 13 4/6 13 0 0 0 3 0.40 i 0.55 0.30 e 38 13 5/8 19 5/13 f 0 5 / 13 BASEMENT c WALL SLAB d VALUE & DEPTH CAWL SPACE c WALL VALUE 8/13 19 10 / 13 10, 2 ft 10/13 4 except 0.35 0.55 N 38 or Marine 13+5 h 5 and 0.32 0.55 N 49 or 13/17 30 f g 10/13 10,2ft 10/13 Marine 4 13+5 h 6 0.32 0.55 N 49 +5 or 15/ 30 g 15/19 10,4ft 10/13 13+10 h or 24 7 and 8 0.32 0.55 N 49 +5 or 19/21 38 g 15/19 10,4ft 10/13 13+10 h or 24 For SI: 1 foot = 304.8 mm. a. values are minimums. U-factors and SHGC are maximums. 19 batts compressed into a nominal 2x6 framing cavity such that the value is reduced by 1 or more shall be marked with the compressed batt value in addition to the full thickness value. b. The fenestration U-factor column excludes skylights. The SHGC column applies to all glazed fenestration. c. 15/19 means 15 continuous insulation on the interior or exterior of the home or 19 cavity insulation at the interior of the basement wall. 15/19 shall be permitted to be met with 13 cavity insulation on the interior of the basement wall plus 5 continuous insulation on the interior or exterior of the home. 10/13 means 10 continuous insulation on the interior or exterior of the home or 13 cavity insulation at the interior of the basement wall. d. 5 shall be added to the required slab edge values for heated slabs. Insulation depth shall be the depth of the footing or 2 ft, whichever is less, in zones 1 through 3 for heated slabs. e. There are no SHGC requirements in the Marine zone. f. Basement wall insulation is not required in warm-humid locations as defined by Figure 301.1 and Table 301.1. g. Or insulation sufficient to fill the framing cavity, 19 minimum. h. First value is cavity insulation, second is continuous insulation, so 13+5 means 13 cavity insulation plus 5 insulated sheathing. If structural sheathing covers 25 percent or less of the exterior, insulating sheathing is not required in the locations where structural sheathing is used. If structural sheathing covers more than 25 percent of exterior, structural sheathing shall be supplemented with insulated sheathing of at least 2. i. The second value applies when more than half the insulation is on the interior of the mass wall. j. For impact rated fenestration in wind-borne debris regions the maximum U-factor shall be 0.75 in Zone 2 and 0.65 in Zone 3. (Portions of code change proposal not shown remain unchanged) Commenter=s eason: The building code should be product neutral. It is not appropriate for the code to require builders in these climate zones to use a specific product class (insulated sheathing) to meet the prescriptive requirements when reasonable options are available. This modification to the original proposal adds 24 cavity insulation only options (Table 2) to climate zones 6 through 8 to a level that exceeds the wood frame wall values in those climate zones in the 06 IECC (Table 1) by approximately 30%. The 24 cavity insulation option is within 6% of the insulation value of the plus 5 continuous insulation option (Table 3), but is 700% greater in value than the minimum required window glass (U-0.32) whose area has not been limited in past energy codes. There are + cavity insulation products available in North America including commonly found cavity insulations combined with spray-foam in flash and batt type applications and some spray-foam products. This option will encourage further product innovation as well as greater options for the builders, including more cost effective ways to meet the structural requirements of the IC. Considering that the U-values for windows in these same climate zones in EC13-09/10 increase efficiency by less than 10% over the 06 IECC and the ceiling Values remain the same as the 06, the 24 requirement in wood frame walls in this Public Comment is significant and appropriate. We ask the code body to support the committee s approval of this proposal as modified by this Public Comment.

Wall Value Comparison Calculations Table 1. Base Case Wall 06 IC Climate zones 6-8 Component Value Studs Value Cavity Assembly Value Sheathing ½ OSB.55 0.55 Fiberglass Batt 17.65* 5 1/2" Stud 6.25 Percent for 16" o.c. 23% 77% Total Wall Component Values 8.55 19.95 Total Wall Assembly Value 1.97 15.36 17.33 *6 1/2 19 batt compressed into a 5 1/2 cavity Table 2. Cavity Insulation Only Option 12 IECC zones 6-8 Component Value Studs Value Cavity Assembly Value Cavity Insulation 24 5 1/2" Stud 6.25 Total Wall Component Values 9.18 26.3 Total Wall Assembly Value 1.97.25 22.22 Table 3. Cavity Insulation Only Option 12 IECC zones 6-8 Component Value Studs Value Cavity Assembly Value Sheathing 1 Foam 5.0 5.0 Cavity Insulation 5 1/2" Stud 6.25 Total Wall Component Values 13.0 26.75 Total Wall Assembly Value 2.99.59 23.59

EC157-09/10 Public Comment 3 Corrections to: Column - 5 AND MAINE 4 ow - Wood framed and EC157-09/10 Public Comment 3: Mark Halverson, representing APA, requests Approval as Modified by this Public Comment. Modify the proposal as follows: CLIMATE ZONE oofs Insulation entirely above deck Metal buildings (with 5 3.5 thermal blocks a,b ) Attic and Table 502.2(1) BUILDING ENVELOPE EQUIEMENTS OPAQUE ASSEMBLIES 1 2 3 4 5 AND 6 7 8 EXCEPT MAINE 4 MAINE 15 ci ci ci ci ci 25 25 25 25 ci 25ci 25ci 25ci 25ci 30ci 30ci 35ci 35ci 35ci 35ci 19 19 13 + 13 + 13 + 19 13 + 19 13 + 19 13 + 19 13 + 19 + 19 19 + 19 + 13 13 13 19 + 13 19 + 13 19 + 19 25 + 19 11xx + + 11Ls 11Ls 19 + 13 + 19 + 11Ls 19 + 11Ls 19 + 11Ls 25 + 11Ls 30 + 10xx 19 10xx 11Ls 19 11Ls 11Ls 11Ls 11Ls 11Ls 30 + 30 + 30 11Ls 11Ls + 11Ls 30 38 38 38 38 38 38 38 38 38 38 38 38 38 49 49 38 49 49 49 49 Walls, Above Grade Mass N 25ci 25ci 5.7ci 5.7ci 5.7ci 7.6ci 7.6ci 9.5ci 9.5ci 11.4ci 11.4ci 13.3ci 13.3ci 15.2ci 15.2ci 15.2ci Metal 16 building b 13+ 6,5c.i. Metal framed 13 + 5 ci 16 13+ 6,5c.i. Wood framed 13 + 13 + and 3.8c.i. 3.8c.i. or or 16 13+ 6,5c.i. 16 13+ 13c.i. 19 13+ 6,5c.i 16 13+ 13c.i 16 13+ 13c.i 16 13+ 13c.i 13 + 13+ 13c.i 13 + 13 + 13 + 19 + 19 + 19 + 19 + 13+ 13+ 13+ 13+ 13+ 13+ 13+ 13c.i 13c.i 13c.i 13c.i 19.5c.i 13c.i 26c.i 13 + 13 + 13 + 13 + 13 + 13 + 13 + 13 + 13 + 13 + 13 + 13 + 13 + 13 + 13 5 ci 5 ci 7.5 + 3.8ci 1 18.8ci 13 + 13 3.8c.i or + 3.8c.i. or 5 ci 13 + 3.8c.i. or 13 + 3.8c.i. or 13 + 3.8c.i. or N N N N N N Walls, Below Grade Below-grade N wall d Floors Mass N N 6.3ci 8.3ci 6.3ci 8.3ci 10ci 10ci 13 + 3.8ci or 10ci 10.4ci 13 + 13 + 13 + 13 + 13 + 13 + 13 + 13 3.8 7.5 7.5 + 3.8ci 7.5 c.i c.i. or c.i. or 1 1 or or 23. 23 23 or 23 or 23 or 30 or 30 10ci 12.5ci 12.5ci 14.6ci 10ci 12.5ci 10ci 10ci 15ci 16.7ci 15ci 16.7ci Joist/Framing N N 19 30 19 30 30 30 30 30 30 30 e 30 30 e 30 e 30 e Slab-on-Grade Floors Unheated slabs N N N N N N N 10 10 24 N 10 10 10 15 15 15 15

CLIMATE ZONE Heated slabs 7.5 Opaque Doors Swinging 1 2 3 4 EXCEPT MAINE 7.5 7.5 7.5 10 10 5 AND MAINE 4 6 7 8 15 15 15 15 15 for 48 for 48 for 48 for 48 36 36 36 U-0.70 U-0.70 U-0.70 U-0.70 U-0.70 U-0.70 U-0.70 U-0.70 U-0.70 U-0.70 U-0.70 U-0.70 U-0.50 U-0.50 U-0.50 U-0.50 U-0.61 U-0.61 U-0.61 U-0.61 U-0.61 U-0.61 U-0.61 U-0.61 U-0.37 U-0.37 U-0.37 U-0.37 U-0.37 U-0.37 U-0.37 U-0.37 oll-up or sliding U-1.45 U-1.45 U-1.45 U-1.45 U-1.45 U-1.45 U-0.50 U-0.50 U-0.50 U-0.50 U-0.50 U-0.50 U-0.50 U-0.50 U-0.50 U-0.50 4.75 4.75 4.75 4.75 4.75 4.75 4.75 4.75 4.75 4.75 4.75 4.75 4.75 4.75 4.75 4.75 For SI: 1 inch = 25.4 mm. ci = Continuous insulation. N = No requirement. a. When using value compliance method, a thermal spacer block is required, wise use the U-factor compliance method. [see Tables 502.1.2 and 502.2(2)]. b. Assembly descriptions can be found in Table 502.2(2). c. 5.7 ci is allowed to be substituted with concrete block walls complying with ASTM C 90, ungrouted or partially grouted at 32 inches or less on center vertically and 48 inches or less on center horizontally, with ungrouted cores filled with material having a maximum thermal conductivity of 0.44 Btu-/h-f2 F. d. When heated slabs are placed grade, -grade walls must meet the exterior insulation requirements for perimeter insulation according to the heated slab-on-grade construction. e. Steel floor joist systems shall to be 38. (Portions of code change proposal not shown remain unchanged) Commenter=s eason: The building code should be product neutral. It is not appropriate for the code to require builders in these climate zones to use a specific product class (insulated sheathing) to meet the prescriptive requirements when reasonable options are available. This modification to the original proposal adds 23 cavity only insulation options to above grade wood framed walls in climate zones 5 through 7, which is equivalent to the 13 + 7.5 continuous insulation option already found in the proposal. In addition, a 30 cavity only insulation option was added to climate zone 8. These options exceed the wood frame wall values in the 06 IECC by 67% and 32%, respectively. Cavity only options in these climate zones will increase energy efficiency while facilitating a wider variety of exterior cladding options. We ask the code body to support the committee s approval of this proposal as modified by this Public Comment.

Assembly Wall Value Calculations: Table 1. Current 12 IECC Climate zones 5 7 (13 + ) Component Value Studs Value Cavity Sheathing continuous insulation 7.5 7.5 Assembly Value 3 1/2" Fiberglass Batt 13.0 3 1/2" Stud 4.38 Total Wall Component Values 14.18 27.45 Total Wall Assembly Value 3.26 17.56.82 Table 2. Base Case Wall 06 IECC Climate zone 5-7 Component Value Studs Value Cavity Assembly Value Sheathing ½ OSB.55 0.55 3 1/2" Fiberglass Batt 13.0 3 1/2" Stud 4.38 Total Wall Component Values 6.68 15.3 Total Wall Assembly Value 1.54 11.78 13.32 Table 3. Cavity Insulation Only Option 12 IECC Climate zone 5-7 Component Value Studs Value Cavity Assembly Value Cavity Insulation 23 5 1/2" Stud 6.25 Total Wall Component Values 8.55 25.3 Total Wall Assembly Value 1.97 19.48 21.45 Table 4. Base Case Wall 06 IECC Climate zone 8 Component Value Studs Value Cavity Assembly Value Sheathing continuous insulation 7.5 7.5 3 1/2" Fiberglass Batt 13.0 3 1/2" Stud 4.38

Total Wall Component Values 14.18 27.45 Total Wall Assembly Value 3.26 17.56.82 Table 5. Cavity Insulation Only Option 12 IECC Climate zone 8 Component Value Studs Value Cavity Assembly Value Cavity Insulation 30 3 1/2" + 3 ½ Studs 8.75 Total Wall Component Values 11.05 32.3 Total Wall Assembly Value 2.54 24.87 27.41

EC176-09/10: eport of Hearing result should be as follows: EC176-09/10 Committee Action: Approved as Submitted Committee eason: The committee felt the proposal clarified determination of energy equivalency and corrected an oversight in previous changes to the code. Assembly Action: None