LED Light Sources for Stopped- Flow Spectroscopy

Similar documents
Stopped-Flow Fluorescence Polarisation/Anisotropy

UV Fluorescence Polarization as a Means to Investigate Protein Conformational and Mass Change

Biochemistry. Biochemical Techniques. 18 Spectrofluorimetry

Fluorescence Quenching of Human Serum Albumin by Caffeine

Contact Details. Dr Alexander Galkin. Office: MBC Room 186. Tel: (028) Frequency and wavelength.

Time-resolved Measurements Using the Agilent Cary Eclipse Fluorescence Spectrophotometer A Versatile Instrument for Accurate Measurements

The Green Fluorescent Protein. w.chem.uwec.edu/chem412_s99/ppt/green.ppt

Time resolved fluorescence spectroscopy: An old technique to monitor protein higher order structure changes

SensoLyte 490 MMP-1 Assay Kit *Fluorimetric*

1. INTRODUCTION 2. EXPERIMENTAL 3. REFERENCES

Quantitative Evaluation of the Ability of Ionic Liquids to Offset the Cold- Induced Unfolding of Proteins

AnaTag 5-FAM Protein Labeling Kit

INVESTIGATION OF THE INTERACTION BETWEEN NAPROXEN AND HUMAN SERUM ALBUMIN

SensoLyte 490 MMP-3 Assay Kit *Fluorimetric*

Crystal Growth, Optical and Thermal Studies of 4-Nitroaniline 4- Aminobenzoic Acid: A Fluorescent Material

SensoLyte 520 Enterokinase Activity Assay Kit *Fluorimetric*

Investigation of dendrimers functionalized with eosin as macrophotoinitiators for polymerization-based signal amplification reactions

luminometer.committed

Concept review: Fluorescence

A photoprotection strategy for microsecond-resolution single-molecule fluorescence spectroscopy

QUENCHING MECHANISM OF HUMAN SERUM ALBUMIN FLUORESCENCE BY GANGLERON

Frequency-Domain Lifetime Measurements Using ChronosFD

Measurement of Enzyme Kinetics by UV-Visible Spectroscopy

SensoLyte 490 MMP-1 Assay Kit *Fluorimetric*

Origin of Tryptophan Fluorescence Lifetimes in Solution and in Proteins. Jihad René Albani Université de Lille 1. Laboratoire Biophysique Moléculaire

The mechanism(s) of protein folding. What is meant by mechanism. Experimental approaches

SensoLyte 520 MMP-1 Assay Kit *Fluorimetric*

SensoLyte 570 Generic MMP Assay Kit *Fluorimetric*

SensoLyte 490 MMP-9 Assay Kit *Fluorimetric*

AnaTag HiLyte Fluor 750 Microscale Protein Labeling Kit

The effect of temperature on the rate of an enzyme catalyzed reaction. Subtitle

Microscale Thermophoresis

SensoLyte Plus 520 MMP-1 Assay Kit *Fluorimetric and Enhanced Selectivity*


Quantify protein stability with ΔG

The New Wave in Spectroscopy FS-2 FluoroMate Fluorescence Spectrometer

Supporting Information

Rapid Kinetics with IR Protein folding examples

Does Myoglobin Unfold in the Body? 1

Protein folding studies to date are mainly focused on small,

SensoLyte Rh110 Factor Xa Assay Kit *Fluorimetric*

Interaction of 4-Nitroaniline with Serum Albumin

Fluorescence Measurements of Denatured Proteins within Electrospray Droplets

How to Build the World s Fastest Spectrofluorometer. MF 2 Multi-Frequency Fluorometer

COMPUTER SIMULATION OF ENZYME KINETICS

SensoLyte 440 West Nile Virus Protease Assay Kit *Fluorimetric*

Fluorescense. Aromatic molecules often fluoresce (but DNA bases don't) Excitation ~ absorbance (Differences due to: ν h ' Fluorescence

AnaTag HiLyte Fluor 488 Microscale Protein Labeling Kit

AnaTag HiLyte Fluor 647 Microscale Protein Labeling Kit

SensoLyte Rh110 Factor Xa Assay Kit *Fluorimetric*

Stability of sub-unit vaccines measured with the UNit label-free stability platform

Supplementary Note 1. Enzymatic properties of the purified Syn BVR

AnaTag HiLyte Fluor 555 Protein Labeling Kit

nanodsf 2bind: Your service provider for biophysical characterization of proteins Precisely revealing protein folding and stability

SensoLyte 520 Factor Xa Assay Kit *Fluorimetric*

Product Information Sheet (M ) MarkerGene TM Fluorescent Protease Assay Kit (Product M1319)

Fluorescence & UV- Visible Workshop

Fluorescence spectroscopy

Electronic Supplementary Information

LIGAND BINDING LABORATORIES

AnaTag HiLyte Fluor 647 Protein Labeling Kit

Fluorescence spectroscopy

Thermo Scientific GENESYS 10S Bio spectrophotometer

Multi-Volume Based Protein Quantification

Biochemical Analysis The Lambda Series UV/Vis Spectroscopy

Drug/protein interactions studied by time-resolved fluorescence spectroscopy

Chem 344 slides for Kinetics Methods extras!

Dr. Jeffrey P. Thompson bio350

Spectroscopy with UVC LEDs in Environmental Monitoring & Life Sciences

Proteasome Activity Fluorometric Assay Kit II (Cat. # J4120)

Refold SK Protein Refolding Kit

DENATURATION OF HEMOGLOBIN IN THE PRESENCE OF TANNIC ACID

Characterization of mab aggregation using a Cary 60 UV-Vis Spectrophotometer and the Agilent 1260 Infinity LC system

DeltaPro. DeltaFlex FORENSICS PARTICLE CHARACTERIZATION ELEMENTAL ANALYSIS FLUORESCENCE GRATINGS & OEM SPECTROMETERS OPTICAL COMPONENTS RAMAN

DeltaPro. DeltaFlex FLUORESCENCE FORENSICS PARTICLE CHARACTERIZATION ELEMENTAL ANALYSIS FLUORESCENCE GRATINGS & OEM SPECTROMETERS OPTICAL COMPONENTS

SpectraMax Multi-Mode Microplate Readers

SensoLyte 620 HCV Protease Assay Kit *Fluorimetric*

SensoLyte 490 HCV Protease Assay Kit *Fluorimetric*

Supporting Information for

Genova Nano. Micro-volume Spectrophotometer

Data Sheet PDE Assay Kit Catalog # 60300

Data Sheet PDE5A Assay Kit Catalog # GWB-PS22C9

SensoLyte AMC Calpain Activity Assay Kit *Fluorimetric*

E1 LITE - UBE1 Activity Assay Kit. Catalog Number UC105

Self-Assembled Nanostructures Based on Activatable Red. Fluorescent Dye for Site-Specific Protein Probing and. Conformational Transition Detection

An anti-galvanic replacement reaction of DNA templated silver. nanoclusters monitored by light-scattering technique

Optimizing Dual-Glo Luciferase Assays with the Synergy HT Multi-Detection Microplate Reader

+ M III. IMAP Screening Express Kit Product #8073 Quantity: 8000, 20 µl reactions (80 µl final volumes) Low FP. M III High FP.

Fluorescence spectroscopy

Enzymes and Enzymatic Reactions Adapted with permission from the original author, Charles Hoyt

Binding of bioactive coomassie brilliant blue G with protein:

PolarScreen Tyrosine Kinase Assay Kit, Far Red Protocol

Revealing a Concealed Intermediate that Forms after the Rate-limiting Step of Refolding of the SH3 Domain of PI3 Kinase

Fragment-based screening of enzyme drug targets: Microfluidic mobility shift assay improves confidence in candidate selection

and electron tunneling through proteins. Small-scale motions such as side-chain protein can take microseconds to seconds, depending on the protein.

SECOND DERIVATIVE UV FOR RAPID CONFORMATIONAL ASSESSMENT OF PROTEINS

Beacon Protease Activity Detection Kit Protocol

SUPPLEMENTARY MATERIAL

Site-specific time-resolved FRET reveals local variations in the unfolding mechanism in an apparently two-state protein unfolding transition

Quantum Dot Band Gap Investigations

Transcription:

SX SERIES APPLICATION NOTE LED Light Sources for Stopped- Flow Spectroscopy Abstract: Applied Photophysics Ltd is offering a range of light emitting diode (LED) light sources for use in stopped-flow spectroscopy in the UV-Vis range. These light sources provide an alternative to the xenon arclamp and monochromator of the SX20, offering high light intensity, high stability, long lifetime and robustness, and at a fraction of the cost. This application note underlines the suitability of these LED light sources for stopped-flow applications. INTRODUCTION LED technology has progressed dramatically in the last few years, to the point that there are a wide variety of high brightness monochromatic LED s at wavelengths from the UV (~260nm) to the NIR. These new light sources have a number of advantages over traditional monochromatic light sources like the xenon arc amp and monochromator of the standard SX20 stopped-flow spectrometer. These advantages are: a low cost, high light intensity, high light stability, long lifetime, robustness and small footprint. For laboratories conducting stopped-flow at specific wavelengths that do not require the flexibility of the xenon arc-lamp and monochromator, Applied Photophysics Ltd is offering a range of single wavelength LED light sources in the UV-Vis spectral range. These light sources enable the measurement of single wavelength fluorescence and absorbance data with data quality equivalent to or better than the xenon arc-lamp and monochromator of the SX20. In this application note, we demonstrate the capability of the LED light source option to successfully carry out standard fluorescence and absorbance stopped-flow applications. Authors James Law, PhD Lindsay Cole, PhD www.photophysics.com KEYWORDS Light Emitting Diodes, LED FLUORESCENCE Fluorescence SPECTROSCOPY High APPLICATIONS intensity Absorbance Application Kinetics 1: Intrinsic Protein Fluorescence pg. 1 of 10 Stopped-flow spectroscopy Low cost SX20 stopped-flow spectrometer

SX SERIES APP NOTE LED Light Sources for Stopped-Flow Spectroscopy A very common application of stopped-flow fluorescence is the monitoring of intrinsic protein fluorescence. This is most often observed from fluorescence of tryptophan amino acids with excitation peak at 280nm. So an LED with a peak emission intensity of 280nm will handle the majority of applications using intrinsic fluorescence. A good example of this type of application is the analysis of protein unfolding and refolding using chemical denaturants. The trace in Figure 1 shows the refolding of lysozyme using a 280nm LED. Unfolded lysozyme (2.0mg/mL) in 6M guanidinium hydrochloride was rapidly mixed with phosphate buffer, ph 7.2, in a 1:10 volume ratio using an SX20 stopped flow spectrometer with a 280nm LED used for excitation. A 320nm cut-off filter was used to block excitation light and fluorescence was measured with a photomultiplier tube. LED Figure 1. Lysozyme refolding kinetics with a 280nm LED as the excitation source. The red line shows the raw data, the black line shows the fit, and the green line shows the residuals of the fit. The trace can be fitted to a double exponential equation which yielded rate constants of 62 and 3.2 s -1 for the fast and slow phases respectively. For comparison, an equivalent trace recorded with the traditional xenon arc-lamp and monochromator is shown in Figure 2. This fit produced very similar data, with similar rate constants of 56 and 3.5 s -1. The refolding of lysozyme is known to involve a number of intermediates [1], and the above multiphasic reaction kinetics is consistent with this. In a complete study the final denaturant concentration would be varied, from which we could derive a chevron plot. By extrapolation back to 0 denaturation concentration rate constants for folding and unfolding of the protein in buffer can be derived. pg. 2 of 10

w SX SERIES APP NOTE LED Light Sources for Stopped-Flow Spectroscopy XENON Figure 2. Lysozyme refolding kinetics recorded with a xenon arc-lamp light source and a monochromator set to 280nm. The red line shows the raw data, the black line shows the fit, and the green line shows the residuals of the fit. Although this simple experiment is a small snap shot of what would be a much larger study, it demonstrates that LED light sources can be used for stopped-flow studies probing protein intrinsic fluorescence, with wide applications in protein folding and refolding [1] [2], protein ligand binding [3], and protein-protein interactions [4]. Application 2: Ligand Binding by Fluorescence Ligand binding kinetics and protein-protein interactions is a core application area for stopped-flow spectroscopic studies. It allows the calculation of on and off rates, and also it can identify multistep binding mechanisms. Here we show a simple ligand-protein stopped-flow binding experiment, with the fluorophore 8-Anilino-1-naphthalene-sulphonic acid (1μM) (ANS) binding to the protein bovine serum albumin (10μM). On binding of the ANS into a hydrophobic binding pocket, the quenching of fluorescence is relieved and the fluorescence signal of ANS goes up significantly. ANS has an excitation spectrum with a peak ~360nm, with an emission peak >395nm. A very sensitive ANS stopped-flow fluorescence detection system was setup using an excitation LED with a peak wavelength of 360nm, and a 395nm cut-off filter was placed in front of the detector to attenuate scattered excitation light. The result of a single binding reaction of ANS to BSA is shown in Figure 3. pg. 3 of 10

SX SERIES APP NOTE LED Light Sources for Stopped-Flow Spectroscopy LED Figure 3. 8-Anilino-1-naphthalene-sulphonic acid binding to bovine serum albumin. 360nm light source used for excitation. The red line shows the raw data, the black line shows the fit, and the green line shows the residuals of the fit. ANS binds to multiple binding sites on BSA, which exhibits multiphasic binding kinetics. The above kinetic trace has to be fitted with 2 exponentials, with rate constants of 227 and 25.0 s -1 respectively. The complex kinetics is due to the multiple binding sites of ANS to BSA, resulting in multiple parallel binding rates. [5] An LED is suitable for analysis of simple and complex ligand binding reactions, using both fluorescence and absorbance optical probes. The quality of the data compares very favourably with that obtained using the xenon arc-lamp and monochromator as a light source as is shown in Figure 4. XENON Figure 4. 8 -Anilino-1-naphthalene-sulphonic acid binding to bovine serum albumin recorded with a xenon arclamp light source and a monochromator set to 360nm. The red line shows the raw data, the black line shows the fit, and the green line shows the residuals of the fit. pg. 4 of 10

w SX SERIES APP NOTE LED Light Sources for Stopped-Flow Spectroscopy These simple examples show the utility of the LED light-source for following changes in fluorescence. More sophisticated experiments such as Fluorescence resonance energy transfer (FRET) measurements are also possible with an LED light source. [6] A key advantage at a number of wavelengths is the combination of very high light intensity and stability, which work together to dramatically reduce signal to noise of the experiment. ABSORBANCE SPECTROSCOPY APPLICATIONS Application 3: Enzymatic hydrolysis of p-nitrophenyl acetate by α-chymotrypsin Stopped-flow spectroscopy is used widely to understand enzymatic reaction kinetics, probing changes in substrate or cofactors during a reaction with absorbance and fluorescence measurements. Here is an example of the hydrolysis of p-nitrophenyl acetate by α-chymotrypsin probed by absorbance changes at 400nm (Figure 3). This experiment rapidly mixed 30μM α-chymotrypsin (Phosphate buffer, ph7.2, 20% Isopropyl alcohol) with 3mM p-nitrophenyl acetate (Phosphate buffer, ph7.2, 20% isopropyl alcohol). An LED with a peak intensity of 400nm was used as the light source. The hydrolysis is observed by measuring the increased absorbance seen by the released p-nitrophenolate. LED Figure 5. Hydrolysis of p-nitro-phenyl acetate catalysed by α-chymotrypsin. 400nm light source used. The red line shows the raw data, the black line shows the fit, and the green line shows the residuals of the fit. The trace in Figure 5 is typical for mechanisms of a serine proteases, which have been studied extensively [7]. Serine proteases are ubiquitous throughout life where they carry out their essential function in peptide bond hydrolysis. All serine proteases execute their catalytic role at an active site consisting of a catalytic triad. pg. 5 of 10

SX SERIES APP NOTE LED Light Sources for Stopped-Flow Spectroscopy The triad invariably contains a histidine, serine, and an aspartic acid residue. The serine residue acts as a nucleophile on the target carbonyl group whereas the histidine and aspartic acid residues involve themselves in hydrogen transfer and hydrogen bonding. The steps in the catalysed hydrolysis of p-nitrophenyl acetate by α-chymotrypsin and trypsin are shown in Figure 2. Figure 6. Reaction scheme for the enzyme catalysed hydrolysis of p-nitrophenyl acetate. The initial binding step between the enzyme and substrate is a preequilibrium that occurs much faster than the subsequent two steps. The formation of acylated enzyme intermediate is accompanied by the loss of the first product p-nitrophenolate. It is this step that can be observed in the stopped flow experiment due to the intense absorption of light at 400 nm by p-nitrophenolate. The shape of the curve in Figure 5 can be explained if the observable step occurs rapidly compared to the final deacylation step. The initial observed rate occurs when the enzyme-substrate concentration is at its highest. At this point, the rate of formation of p-nitrophenolate depends only on the first two steps of the mechanism. This gives rise to the initial observable burst phase of the reaction. As the reaction proceeds, the acylated enzyme reaches an equilibrium concentration so that the rate becomes dependent only on the final deacylation step, giving rise to the linear part of the trace. (Please refer to application note 4140Q010 for a more complete description of how kinetic and thermodynamic parameters can be obtained from such experiments.) The trace can be described by a single exponential plus a linear slope. The fast phase of the reaction, which includes the first 2 reaction steps, was calculated to be 0.38s -1 and the slow steady state linear phase was determined to be 0.02s -1. For comparison, the experiment was repeated with a xenon arc-lamp and monochromator set to 400nm (Figure 7). pg. 6 of 10

w SX SERIES APP NOTE LED Light Sources for Stopped-Flow Spectroscopy XENON Figure 7. Hydrolysis of p-nitro-phenyl acetate catalysed by α-chymotrypsin recorded with a xenon arc-lamp light source and a monochromator set to 400nm. The red line shows the raw data, the black line shows the fit, and the green line shows the residuals of the fit. SUMMARY The LED light source is able to be used in the majority of standard single wavelength fluorescence and absorbance stopped-flow applications, with a number of advantages: Simple robust design Very small footprint Long light-source life High light intensity High light stability Compact instrument footprint The much reduced cost is also a considerable bonus and the LED light source is likely to be of interest in teaching labs, start-up labs and established kinetics labs wishing to extend their resources. NOTE: It should be kept in mind that, in the absence of a monochromator, the bandwith is effectively set by the LED light source that is used. This is typically in the range 10-30 nm. Naturally, this is a consideration when assessing the most appropriate filter in a fluorescence experiment. pg. 7 of 10

SX SERIES APP NOTE LED Light Sources for Stopped-Flow Spectroscopy ORDERING INFORMATION The SX20 stopped-flow sample housing unit (SHU) equipped with an LED light source. These high intensity, high stability light sources are available in a number of specific wavelength outputs and may be used to compliment or replace the original xenon arc lamp. The LEDs are especially suitable for fluorescence experiments and may also be used in absorbance measurements. The wavelength range currently offered is listed in Table 1, alternative wavelengths may be available on request. REFERENCES Peak Wavelength Bandwidth, FWHM (Approx.) [1] T. Kiefhaber, Kinetic 280 traps in lysozyme folding., Proc. Natl. 11 Acad. Sci., vol. 92, no. 20, pp. 9029 9033, Sep. 1995. [2] S. R. Haq, M. C. 320 Jürgens, C. N. Chi, C.-S. Koh, L. Elfström, M. 10Selmer, S. Gianni, and P. Jemth, The 340 plastic energy landscape of protein folding: 10 a triangular folding mechanism with an equilibrium intermediate for a small protein domain., J. Biol. Chem., vol. 285, no. 360 23, pp. 18051 9, Jun. 2010. 21 [3] A. Bah, L. C. Garvey, 400 J. Ge, and E. Di Cera, Rapid kinetics 16 of Na+ binding to thrombin., J. Biol. Chem., vol. 281, no. 52, pp. 40049 56, Dec. 2006. 435 19 [4] H. N. Bradford and S. Krishnaswamy, Meizothrombin is an unexpectedly zymogen-like variant 450 of thrombin., J. Biol. Chem., vol. 287, no. 20 36, pp. 30414 25, Aug. 2012. 470 20 [5] D. M. Togashi and A. G. Ryder, A fluorescence analysis of ANS bound to bovine serum albumin: binding 490 properties revisited by using energy transfer., 28 J. Fluoresc., vol. 18, no. 2, pp. 519 26, Mar. 2008. 505 28 [6] H. S. Tims and J. Widom, Stopped-flow fluorescence resonance energy transfer for analysis of nucleosome 535 dynamics., Methods, vol. 41, no. 3, pp. 34 296 303, Mar. 2007. [7] L. Hedstrom, Serine 572 protease mechanism and specificity., 14Chem. Rev., vol. 102, no. 12, pp. 4501 24, Dec. 2002. 590 13 610 15 650 20 660 19 680 20 Table 1.Peak emission wavelengths and bandwidths of LED light sources. pg. 8 of 10

w SX SERIES APP NOTE LED Light Sources for Stopped-Flow Spectroscopy REFERENCES [1] T. Kiefhaber, Kinetic traps in lysozyme folding., Proc. Natl. Acad. Sci., vol. 92, no. 20, pp. 9029 9033, Sep. 1995. [2] S. R. Haq, M. C. Jürgens, C. N. Chi, C.-S. Koh, L. Elfström, M. Selmer, S. Gianni, and P. Jemth, The plastic energy landscape of protein folding: a triangular folding mechanism with an equilibrium intermediate for a small protein domain., J. Biol. Chem., vol. 285, no. 23, pp. 18051 9, Jun. 2010. [3] A. Bah, L. C. Garvey, J. Ge, and E. Di Cera, Rapid kinetics of Na+ binding to thrombin., J. Biol. Chem., vol. 281, no. 52, pp. 40049 56, Dec. 2006. [4] H. N. Bradford and S. Krishnaswamy, Meizothrombin is an unexpectedly zymogen-like variant of thrombin., J. Biol. Chem., vol. 287, no. 36, pp. 30414 25, Aug. 2012. [5] D. M. Togashi and A. G. Ryder, A fluorescence analysis of ANS bound to bovine serum albumin: binding properties revisited by using energy transfer., J. Fluoresc., vol. 18, no. 2, pp. 519 26, Mar. 2008. [6] H. S. Tims and J. Widom, Stopped-flow fluorescence resonance energy transfer for analysis of nucleosome dynamics., Methods, vol. 41, no. 3, pp. 296 303, Mar. 2007. [7] L. Hedstrom, Serine protease mechanism and specificity., Chem. Rev., vol. 102, no. 12, pp. 4501 24, Dec. 2002. pg. 9 of 10

4140Q049 V 1.00 SX20 is a trademark of Applied Photophysics Ltd. All third party trademarks are the property of their respective owners. 2011 Applied Photophysics Ltd. All rights reserved. Applied Photophysics Ltd, 21, Mole Business Park, Leatherhead, Surrey, KT22 7BA, UK Tel (UK): +44 1372 386 537 Tel (USA): 1-800 543 4130 Fax: +44 1372 386 477 Email: info@photophysics.com Applied Photophysics was established in 1971 by The Royal Institution of Great Britain www.photophysics.com pg. 10 of 10