BENZIE COUNTY BUILDING SAFETY and CODE ENFORCEMENT DEPARTMENT 448 Court Place, Beulah, Michigan Ph Fax.

Similar documents
FACT SHEET #2 DECK INFORMATION

Campbell County Building Inspection Division Guideline to 2018 IRC Residential Construction for Decks

******************************************************************************

Residential Deck Guide

DECKS CHAMPLIN BUILDING DEPARTMENT DECK PERMIT REQUIREMENTS:

Manufactured decking (composite) may be used when approved by the building department

Typical Deck Details Based on the 2009 International Residential Code (Designed and Printed August 2010)

DECK PERMIT APPLICATION

CARROLL COUNTY BUREAU OF PERMITS AND INSPECTIONS RESIDENTIAL CODE COMPLIANCE GUIDELINES FOR DECKS

DECKS. BUILDING DEPARTMENT 1584 Hadley Avenue N Oakdale, MN Phone: Fax:

14240 W. 151 st Street, Homer Glen, IL Phone Fax Deck Building Guide

DECK CONSTRUCTION REQUIREMENTS

City of St. Peters Residential Deck Guide

DEVELOPMENT SERVICES BUILDING INSPECTIONS

HILLSBOROUGH TOWNSHIP CODE ENFORCEMENT

CITY OF BRISTOL DECK CONSTRUCTION GUIDE ACCORDING TO THE 2012 IRC WITH THE 2016 CT AMMENDMENTS

The following are details of the code requirements of the 2015 International Residential Code for single-story decks.

Typical Deck Details. Shenandoah County, Virginia. Based on the 2012 International Residential Code

Typical Deck Details. Shenandoah County, Virginia. Based on the 2012 Virginia Residential Code

Typical Deck Details. Albemarle County, Virginia. Based on the 2012 Virginia Residential Code

Town of Chili. Building Department 3333 Chili Avenue, Rochester, NY (585) fax: (585) Decks: What You Need to Know

CITY OF BATAVIA DECK CONSTRUCTION REQUIREMENTS

Village of Algonquin

Residential Deck Safety, Construction and Repair. Juneau Permit Center, 4 th Floor Marine View Center,(907) February 2016

Colorado Chapter of the International Conference of Building Officials. Building Guide. Single Family Residential Uncovered Decks and Porches

RESIDENTIAL DECK INFOREMATION SHEETS

CITY OF FRUITLAND DIVISION OF PLAN REVIEW & PERMITTING DECK GUIDE. This design guide assumes all lumber to be pressure-treated Southern Pine.

Residential Decks. NOTE: If you are in a development with a 2. Deck Plan (see below)

2. Plot plan showing deck scaled with stairs. 3. Building Permit Application signed by owner or licensed contractor and fee paid.

BUILDING BULLETIN One and Two Family Dwellings Decks and Residential Access Ramps

Building Guide. Colorado Chapter of the International Conference of Building Officials. Building Guide

Building Your Own Deck Homeowners Information Guide

TYPICAL SELF SUPPORTING DECK ELEVATION VIEW (NOT ATTACHED TO HOUSE)

SCREEN PORCHES 101 DEVELOPMENT RESOURCES, INC Permit Requirements

STAIRWAYS, HANDRAILS, AND GUARDRAILS (RESIDENTIAL)

Residential Decks 1 & 2 Family Dwellings and Townhouses

Screen & 3-Season Porches

RESIDENTIAL WOOD DECK CONSTRUCTION GUIDE

RESIDENTIAL DECK SUBMITTAL GUIDE

Building permits are not required for patios made of concrete or pavers on grade.

Georgia Amendments Prescriptive Deck Details

Typical Deck. CONSTRUCTION TIP SHEET 5 Basic Decks w/ 60 psf Live Loading

TOWN OF BRADFORD WEST GWILLIMBURY DECK PACKAGE

Typical Deck. CONSTRUCTION TIP SHEET 5 Basic Decks w/ 60 lb Live Loading

LINCOLN COUNTY REQUIRED INSPECTIONS (Last updated August 23, 2017)

1 & 2 Family Deck Permits City of Oshkosh Inspection Services Division

Deck Design Guide. 67 Sharp Road, Brighton, Ontario P.O. Box 189 K0K 1H0 Tel: Fax: Web:

Detailed Deck Building

Deck Construction Guide

City of of Dauphin WOOD DECKS. Zoning and construction requirements for non-sheltered wood decks for residential dwellings.

RESIDENTIAL WOOD DECK CONSTRUCTION GUIDE

2003 International Residential Building Code

This tip sheet may be used as a guide for single-family residential uncovered deck permits.

Attached are examples of drawings which are intended as a GUIDE ONLY!!

Uncovered Decks & Porches

RESIDENTIAL DECK REQUIREMENTS CITY OF NOVI Community Development Department (248)

Georgia Amendments Prescriptive Deck Details

Residential Deck Plan Requirements Hugo, Minnesota

Plot Plan for Decks Date. Name Phone # Address Zip APN # _- _- _ (see property tax bill or call the assessor s office ) FRONT PROPERTY LINE

Wood Decks Zoning and construction requirements for open non-sheltered wood decks for residential dwellings

Guidelines for planning the construction of a porch.

Building Department 25 LaGrange Street Newnan, GA Ph Fax

Residential Decks 1 & 2 Family Dwellings and Townhouses City of Owatonna BUILDING DEPARTMENT

2012 Code Update Training

North Strabane Township

Village of Lombard Community Development Department/Building Division 255 E. Wilson Avenue Lombard, IL Tel: Fax:

CITY OF HERCULANEUM. Residential Deck Handout

Porches. NOTE: If you are in a development with a homeowners association, a letter from the Board of Directors approving construction is required.

Decks & Patios Version 4/24/2015

2012 IRC Table R802.4(2) - Ceiling Joist Spans for Common Lumber Species (Uninhabitable Attics With Limited Storage, Live Load = 10 psf, L/Δ = 240)

Typical Deck Details Package For One and Two Family Dwellings

CARBON MONOXIDE ALARMS

RESIDENTIAL WOOD DECK CONSTRUCTION GUIDE

BUILDING PERMIT REQUIREMENTS FOR: RESIDENTIAL DECKS CITY OF ESCONDIDO BUILDING DIVISION 201 N. BROADWAY, ESCONDIDO, CA (760)

STANDARD RESIDENTIAL DECK DETAILS

DECK PLANS

Decks. SPS (1) SPS (2) AKA Appendix B & C

311.7 Stairways Width Headroom. Exception: Walkline Stair treads and risers Tread depth.

Why Decks Fail Design and New PA UCC Requirements to Improve Safety

Wood Decks. Zoning and Construction requirements for open non-sheltered wood decks for residential dwellings.

Project Address: Owner Name: PHONE: Your Deck Plan and Section must include all of the following:

City of Republic Community Development Girder and Header Spans for Exterior Walls

Prescriptive Residential Wood Deck Construction Guide with Commentary DCA IRC Version (BCD 306)

Office of the Fire Commissioner Building and Fire Safety Section

DECK PLANS City Of Grand Rapids Building Safety Division

DECK PLANS. BUILDING DEPARTMENT

The Homeowner s Building Application Checklist for Constructing a Residential Sundeck

GUIDELINES FOR DECK CONSTRUCTION

Department of Building and Zoning Deck Handout for ONE AND TWO FAMILY CONSTRUCTION

Uncovered Decks and Porches

POST AND FRAME STRUCTURES (Pole Barns)

General Requirements Yes N/A 1. Is the designer qualified for the proposed work?

Town Of Littleton. RJB Typical Deck Details Package Based on the 8th Edition One and Two Family Dwelling Code CONTENTS

Wood Decks. Please call for further information. Municipality of Roblin Planning Department st Ave. NW Roblin, Manitoba R0L 1P0

Residential Decks. Permit and Construction Guidelines under the 2012 IRC. Johnson County Building Officials Association

Deck Plans. 112 W Washington Ave. Fergus Falls MN, BUILDING DEPARTMENT

PENNSAFE BUILDING INSPECTION SERVICES LLC Deck and Roof Cross Section Submittal

Lonsdale Building Inspections Department 415 Central Street W. PO Box 357 Lonsdale, MN (507) fax (507)

Administrative Changes

Building a Wood Deck, Gazebo, or Pergola

Transcription:

BENZIE COUNTY BUILDING SAFETY and CODE ENFORCEMENT DEPARTMENT 448 Court Place, Beulah, Michigan 49617 Ph. 231-882-9673 Fax. 231-882-0033 DECK SPEC INFORMATION Footing Inspections: Dig footing to required depth and size and call for an inspection before pouring concrete. Do not cover footings until inspected. Framing Inspections: If framing will be covered and can not be seen from the bottom side of deck, an inspection must be done before framing is covered. Make sure all flashings and water shields are in place. If attached to home make sure all lags or through bolts are in place and joist hangers are fully nailed with required nails. Decks: Where supported by attachment to an exterior wall, decks shall be positively anchored to the primary structure and designed for both vertical and lateral loads as applicable. Such attachment shall not be accomplished by the use of toenails or nails subject to withdrawal. Where positive connection to the primary building structure cannot be verified during inspection, decks shall be self-supporting. For decks with cantilevered framing members, connections to exterior walls or other framing members, shall be designed and constructed to resist uplift resulting from the full live load specified in (Table R301.5 or Table 1607.1) acting on the cantilevered portion of the deck (R502.2.2-502.2.2.4)(1604.8.3). Approved corrosion-resistive flashing shall be installed at all of the following locations: Where exterior porches, decks, or stairs attach to a wall or floor assembly of wood-frame construction. (R703.8(5)) or (1405.4) Porches and decks which are enclosed with insect screening shall be provided with guards where the walking surface is located more than 30 inches above the floor or grade below. (R312.1) (1013.1) Porches, balconies or raised floor surfaces located more than 30 inches above the floor or grade below shall have guards not less than 36 inches in height (R312.1) or 42 inches in height (1013.2). Handrails shall be provided on at least one side of each continuous run of treads or flight with four or more risers for residential (R311.7.7). 1009.12 Handrails. Stairways shall have handrails on each side and shall comply with Section 1012. Where glass is used to provide the handrail, the handrail shall also comply with Section 2407. Minimum Stairway width is 36 inches, maximum riser height is 8 ¼ inches, minimum tread width is 9 inches (nose to nose). (R311.7.1, R311.7.4.1, R311.7.4.2) Residential Minimum Stairway width is 44 inches, unless serving an occupant load of 50 or less, it can than be 36 inches (1009.1). Stair riser heights shall be 7 inches maximum and 4 inches minimum. Stair tread depths shall be 11 inches minimum (1009.4.2) Commercial applications Decks serving commercial situations need be live loaded same as occupancy served. (Table 1607.1) Provide scale drawings showing deck design (material and sizes), footing, connections, loading, stair systems, distance from grade, handrails, attachments, flashings, and guards are required. The following information is to better help you properly live load decks for 40, 60 and 100 pound live load situations. This may not work for every situation or design, but should be considered as a guide to loading decks. Design professionals may be necessary for some deck situations and is encouraged. 1

SOUTHERN PINE PONDEROSA or RED PINE Wet-Service Joists 40psf live load, 10psf dead load, L/360 Wet-Service Joists 40psf live load, 10psf dead load, L/360 12 10-9 10-7 10-4 9-4 12 9-5 9-2 8-10 7-6 16 9-9 9-7 9-5 8-1 16 8-7 8-4 8-0 6-6 24 8-7 8-5 7-10 6-7 24 7-6 7-2 7-0 5-4 12 14-2 13-11 13-8 11-11 12 12-5 12-1 11-8 9-6 16 12-11 12-8 12-5 10-3 16 11-3 10-11 10-7 8-3 24 11-3 11-1 10-2 8-5 24 9-10 9-0 9-0 6-9 12 18-1 17-9 17-5 14-0 12 15-10 15-4 14-11 11-8 16 16-5 16-2 15-10 12-2 16 14-4 13-6 13-6 10-1 24 14-4 13-6 13-1 9-11 24 12-7 11-0 11-0 8-3 12 22-0 21-7 21-2 16-8 12 19-3 18-1 18-1 13-6 16 20-0 19-8 18-10 14-6 16 17-6 15-8 15-8 11-8 24 17-6 16-1 15-5 11-10 24 14-9 12-10 12-10 9-6 Wet-Service Joists 60psf live load, 10psf dead load, L/360 12 9-5 9-3 9-1 7-11 16 8-7 8-5 8-1 6-10 24 7-6 7-4 6-8 5-7 12 12-5 12-2 11-11 10-0 16 11-3 11-1 10-6 8-8 24 9-10 9-7 8-7 7-1 12 15-10 15-6 15-2 11-10 16 14-4 13-11 13-7 10-3 24 12-7 11-5 11-1 8-5 12 19-3 18-10 18-5 14-1 16 17-6 16-7 15-11 12-3 24 15-3 13-7 13-0 10-0 Wet-Service Joists 60psf live load, 10psf dead load, L/360 12 8-3 8-0 7-9 6-4 16 7-6 7-3 7-0 5-6 24 6-5 6-0 6-0 4-6 12 10-10 10-6 10-2 8-1 16 9-10 9-4 9-3 7-0 24 8-7 7-8 7-8 5-8 12 13-10 13-2 13-0 9-10 16 12-7 11-5 11-5 8-6 24 10-9 9-4 9-4 6-11 12 16-10 15-4 15-4 11-5 16 15-3 13-3 13-3 9-10 24 12-6 10-10 10-10 8-1 Wet-Service Joists 100psf live load, 10psf dead load, L/360 Wet-Service Joists 100psf live load, 10psf dead load, L/360 12 7-11 7-9 7-6 6-3 12 6-11 6-9 6-6 5-1 16 7-2 7-1 6-6 5-5 16 6-3 5-11 5-11 4-5 24 6-4 6-1 5-3 4-5 24 5-1 4-10 4-10 3-7 12 10-5 10-3 9-8 8-0 12 9-2 8-7 8-7 6-5 16 9-6 9-4 8-4 6-11 16 8-4 7-6 7-6 5-7 24 8-4 7-8 6-10 5-8 24 7-0 6-1 6-1 4-6 12 13-4 12-10 12-6 9-5 12 11-8 10-6 10-6 7-10 16 12-1 11-1 10-10 8-2 16 10-6 9-1 9-1 6-9 24 10-4 9-1 8-10 6-8 24 8-7 7-5 7-5 5-7 12 16-3 15-4 14-8 11-3 12 14-1 12-2 12-2 9-1 16 14-9 13-3 12-8 9-9 16 12-2 10-7 10-7 7-11 24 10-4 10-4 10-4 8-0 24 10-0 8-8 8-8 6-5 2

BEAM CARRIER SIZE TABLES 40 PSF LIVE 10 PSF DEAD #2 & Better PONDEROSA PINE ---- BETWEEN POSTS -- -- or RED PINE 4-0 1-2X4 1-2X6 1-2X6 2-2X6 2-2X6 2-2X8 2-2X8 2-2X8 1-2X8 1-2X8 1-2X10 1-2X12 1-2X10 2-2X10 6-0 1-2X6 1-2X6 2-2X6 2-2X6 1-2X8 1-2X10 1-2x12 8-0 1-2x6 1-2x8 1-2x12 10-0 1-2x6 1-2x8 1-2x12 12-0 1-2x8 4-2x12 1-2x8 4-2x12 4-2x12 16-0 4-2x12 4-2x12 **** 18-0 4-2x12 **** **** 20-0 4-2x12 4-2x12 **** **** #2 & Better SOUTHERN PINE -- -- BETWEEN POSTS 4-0 1-2x4 1-2x4 1-2x6 1-2x6 1-2x6 6-0 1-2x4 1-2x6 1-2x6 1-2x8 1-2x8 8-0 1-2x6 1-2x6 1-2x6 1-2x8 10-0 1-2x6 1-2x6 1-2x8 12-0 1-2x6 1-2x8 1-2x12 1-2x8 1-2x8 16-0 1-2x8 1-2x12 18-0 1-2x8 20-0 1-2x8 Table Notes: 1-2x8 1-2x8 1-2x12 1-2x12 1-2x12 4-2x12 1. Joists = (1) span only 2. Carrier must be (2) span 3. Carrier must be bearing on top of post or, the connection to the post must be sufficient to transfer the design loads. ( Lags, pole barn nails, hangers, ect;) 3

BEAM CARRIER TABLES 60 PSF LIVE 10 PSF DEAD #2 & Better PONEROSA PINE -- BETWEEN POSTS -- or RED PINE 4-0 1-2x6 1-2x6 1-2x8 1-2x8 6-0 1-2x6 1-2x8 8-0 1-2x8 10-0 1-2x8 4-2x12 12-0 4-2x12 **** 4-2x12 **** **** 16-0 4-2x12 **** **** 18-0 4-2x12 **** **** **** 20-0 4-2x12 4-2x12 **** **** **** #2 & Better SOUTHERN PINE ---- BETWEEN POSTS 4-0 1-2x4 1-2x6 1-2x6 1-2x8 1-2x8 6-0 1-2x6 1-2x6 1-2x8 1-2x8 8-0 1-2x6 1-2x8 1-2x8 10-0 1-2x8 1-2x8 12-0 1-2x8 4-2x12 16-0 4-2x12 4-2x12 18-0 4-2x12 **** 20-0 4-2x12 4-2x12 **** Table Notes: 1. Joists = (1) span only 2. Carrier must be (2) span 3. Carrier must be bearing on top of post or, the connection to the post must be sufficient to transfer the design loads. ( Lags, pole barn nails, hangers, ect;) 4

BEAM CARRIER TABLES 100 PSF LIVE 10 PSF DEAD #2 & Better PONDEROSA PINE -- -- BETWEEN POSTS -- -- or RED PINE 4-0 1-2x6 1-2x8 1-2x8 1-2x12 6-0 1-2x6 1-2x8 8-0 1-2x8 1-2x12 4-2x12 4-2x12 10-0 1-2x8 4-2x12 4-2x12 **** 12-0 1-2x12 4-2x12 4-2x12 **** **** 4-2x12 **** **** **** 16-0 4-2x12 **** **** **** **** 18-0 4-2x12 **** **** **** **** 20-0 4-2x12 **** **** **** **** **** #2 or Better SOUTHERN PINE -- BETWEEN POSTS 4-0 1-2x6 1-2x6 1-2x8 1-2x8 1-2x12 6-0 1-2x6 1-2x8 1-2x8 1-2x12 8-0 1-2x6 1-2x8 1-2x12 10-0 1-2x8 1-2x12 4-2x12 12-0 1-2x12 4-2x12 4-2x12 1-2x12 4-2x12 4-2x12 **** 16-0 4-2x12 **** **** 18-0 4-2x12 **** **** **** 20-0 4-2x12 **** **** **** Table Notes: 1. Joists = (1) span only 2. Carrier must be (2) span 3. Carrier must be bearing on top of post or, the connection to the post must be sufficient to transfer the design loads. ( Lags, pole barn nails, hangers, ect;) 5

[] Will provide at least two(2) hold-down tension devices in not less than two locations capable of a design capacity of not less than 1500 pounds each. This device shall be similar to Fig. R502.2.2.3. 6

7