Centre d expertise en analyse environnementale du Québec

Similar documents
Sample for use a Guide Revised IDEXX COLILERT -18 TEST METHOD FOR THE SIMULTANEOUS DETECTION OF TOTAL COLIFORMS AND E.

The Importance of Laboratory Support in the Implementation of Water Safety Plans. Mark Rodgers

WATER SAMPLING INSTRUCTIONS READ CAREFULLY AND COMPLETELY BEFORE SAMPLE COLLECTION Call the laboratory if you have questions.

Drinking Water Quality Sampling. The Why, Where, When, and How

Surface Water Samples: Containers, Preservation and Hold Times Table

Sample for Use as a Guide Revised IDEXX ENTEROLERT TEST METHOD FOR THE DETECTION OF ENTEROCOCCI IN WATER

Sampling Day Activities

Ground Water Rule: A Quick Reference Guide Overview of the Rule

Wipes for Disclosing the Presence of Lead

Central Laboratory, M.P. Pollution Control Board, Bhopal [M.P.]

Ground Water & UST Samples: Containers, Preservation and Hold Times Table

Free Chlorine Distribution System Influent Hold Study Protocol (April 2019)

ANALYTICAL PROCEDURE. Bacteria: Hydrogen Sulfide Producing

Manual No Revision MODEL GLI HAND-HELD/PORTABLE TOTAL/FREE CHLORINE METER

BUREAU OF CLEAN WATER RECREATIONAL USE ASSESSMENT METHODOLOGY BACTERIOLOGICAL SAMPLING PROTOCOL

How to Collect Your Water Sample and Interpret the Results for the Poultry Analytical Package

Sampling Surface and Ground Water Sources Compiled by Deanne Meyer and Patricia Price Department of Animal Science, UC Davis, September 2012

New York State Department of Health - Wadsworth Center Laboratory of Environmental Biology NYS ELAP Laboratory ID 10765

Back TO Basics: Sample Collection & Handling

New York State Department of Health - Wadsworth Center Laboratory of Environmental Biology NYS ELAP Laboratory ID 10765

By Authority Of THE UNITED STATES OF AMERICA Legally Binding Document

Method Measurement of Enterovirus and Norovirus Occurrence in Water by Culture and RT-qPCR. EPA/600/R-10/181 December 2010

With Discovery Incubator.

Standard Operating Procedure for: Water Sample Collection (1040R01 Water Sampling.doc) Missouri State University. and

SSMP ELEMENT 6 Overflow Emergency Response Plan APPENDIX 6.7. Water Quality Monitoring Program

TECHNICAL LEAFLET. MEDI-MEDIA-FILL KIT SUPPLY PACKAGE (Code: MR-25/S)

Sampling for Recreational Water Quality Monitoring

Completing. By the end of this chapter, you will be able to: Introduction. Chapter 16

Water sampling and preservation techniques. A.Gnanavelu CPCB, BANGALORE

Oxygen Demand, Chemical

Oxygen Demand, Chemical

Copyright 2017 Aegis Sciences Corporation All Rights Reserved

Measuring Dissolved Oxyg Instructions for the La Motte Field-Test Kit

Ecoli 360 HCP ELISA ELISA Kit for the Determination of Ecoli-HCP in process-derived Samples

Modified Colitag Test Method for the Simultaneous Detection of E. coli and other Total Coliforms in Water (ATP D ) August 28, 2009

USEPA Membrane Filtration Method Method m-tec. Scope and Application: For potable water, nonpotable water, recreation water and wastewater.

23, SEDIMENT COLLECTIONS

Revised 27 Aug rm (Vers. 4.1)

WASHINGTON CONSERVATION DISTRICT STANDARD OPERATING PROCEDURE (S.O.P.)

CARE SERVICE USER GUIDE. Sonicision System

Collection, Handling, and Transport of Food Samples to NM SLD

Color, True and Apparent, LR

Approved for NPDES (Editorial Revision 1978) Silica, Dissolved (Colorimetric)

STANDARD OPERATING PROCEDURES

New York State Department of Health - Wadsworth Center Laboratory of Environmental Biology NYS ELAP Laboratory ID 10765

Water Sample Collection and Analysis

Laboratory Biosafety Plan

New York State Department of Health - Wadsworth Center Laboratory of Environmental Biology NYS ELAP Laboratory ID 10765

Abalone Coast Analytical Laboratory Quality Assurance Manual

Radiation Safety Program Hunter College of the City University of New York

HHV-6 IgG ELISA Kit. Cat.No: DEIA3565 Lot. No. (See product label) Size. Intended Use. General Description. Principle Of The Test

Water Quality Assessment of Hand Dug Wells

HBeAg and HBeAg Ab ELISA Kit

Soybean dwarf virus Reagent Set DAS ELISA for the detection of SbDV Catalog number: SRA 15500

Coliforms, Total and E. coli

Microbial Media and Culture Dishes

Instruction Manual HI RH/ C Transmitter. This Instrument is in Compliance with the CE Directives.

AmoyDx FFPE RNA Kit. (Spin Column) For purification of total RNA from formalin-fixed, paraffin-embedded tissue sections. Instruction for Use

RNAPro SAL ORAL SPECIMEN COLLECTION SYSTEM. Catalog Number RPSAL-701. Transparent Plastic Compression Tube. Compression Seal

Bacterial Reagent Set Indirect ELISA, Alkaline phosphatase label

Collecting a Surface Water Sample

Puritan Environmental Sampling Kit (ESK )

SAFETY DATA SHEET PS Rev. 1

National Standard of the People s Republic of China

3.0 DETECTION LIMIT 3.1. See Procedure ALQAP Procedure for the Determination of Uncertainty

DRG International, Inc., USA Fax: (908)

FI J Page 1 of 11

Zinc Testing and On Site Calibration for Water Testing Detection Range: 1 15ppm

Urine Protein Concentration, Preservation and Isolation Kit 25 Individual Devices Product Insert Product #: 38200

Method 0040 for Volatile Total Organics as Unspeciated Mass in Stack Gas Emissions

Item 96 wells 500 wells 1000 wells 5000 wells

Development of standard laboratory based test to measure compost stability Annex A

Instrument Adapters Light shield DR 6000, DR 5000 DR 3900 LZV849 DR 3800, DR 2800 LZV646 DR or (A)

F U C H S L U B R I C A N T S C O.

Environmental. National Legionella Conference Sample Taking Workshop. Right Solutions Right Partner

Microbiology Methods for Drinking Water Laboratories. Erica Fox

Group Stormwater Compliance Program Sampling Instructions

New York State Department of Health - Wadsworth Center Laboratory of Environmental Biology NYS ELAP Laboratory ID 10765

Actero Salmonella Enrichment Media Product Information

Human IL-1 alpha ELISA Kit

SAMPLING AND ANALYSIS PLAN. Crow Creek in Cheyenne

Standard Test Section: SAMPLING Procedures Manual

Standard Operating Procedure Title: Stock Suspensions of Micro-Organisms

Scottish Health Technical Memorandum 04-01: Water safety for healthcare premises: Part C: TVC Testing Protocol

Uranium Testing and Site Calibration for Water Testing Detection Range: 2 60ppb

EMSL Cryptosporidium and Giardia (EPA 1623/1623.1) Sampling and Shipping Instructions. Instructions for Field Filtered Samples (10 or 50 Liters)

Recommended Guidelines For Sampling Emulsified Bituminous Materials

PicoKine ELISA. Catalog number: EK7102. For the quantitation of Human concentrations in Serum and Plasma

Collecting a Surface Water Sample

Bovine IgG ELISA Kit

Dimethylphenol Method Method LR (0.23 to mg/l NO 3 N or 1.00 to mg/l NO 3 ) TNTplus 835

Actero Salmonella/STEC Enrichment Media Product Information

DNA TRANSFORMATION OF BACTERIA RED COLONY REVISED 3/2003

cobas PCR Cell Collection Media

STANDARD OPERATING PROCEDURES DIVISON OF COMPARATIVE MEDICINE UNIVERSITY OF SOUTH FLORIDA

A natural impurity in water. The test will measure the amount of free oxygen "gas" dissolved in your water sample in ppm (mg/l).

DR/4000 PROCEDURE. OXYGEN DEMAND, Chemical. Colorimetric Measurement, 0 to 40 mg/l COD

Human IL-6 ELISA Set

Standard Operating Procedure for: Water Sample Collection with Nalgene 1100 Samplers (Water Sampling with Nalgene 1100 Sampler.

Guidelines for Water Quality Testing and Monitoring A Practical Guide to the Design and Implementation of Drinking Water Quality Studies and

Transcription:

Centre d expertise en analyse environnementale du Québec Methods for taking, preserving and analyzing samples to monitor the water quality of pools and other artificial reservoirs DR-09-05 Edition 2007-06-20 Revised 2009-09-10

Gouvernement du Québec, 2009

TABLE OF CONTENTS INTRODUCTION...5 1 GENERAL PRECAUTIONS...7 2 ON-SITE ANALYSIS...7 2.1 Specific Precautions... 7 2.2 Preservation Methods...7 2.3 Sampling Method...8 2.4 Analysis Methods... 9 2.4.1. Water temperature... 9 2.4.2. Other Parameters... 9 3 LABORATORY ANALYSIS...9 3.1 Specific Precautions... 9 3.2 Preservation Methods...10 3.3 Sampling Method...11 LEGEND...12 DR-09-05 Page 3 of 12

LIST OF TABLES Table 1: Preservation methods for chemical parameters (on-site analysis)... 8 Table 2: Preservation methods for microbiological and chemical parameters (laboratory analysis)... 11 Page 4 of 12 DR-09-05

INTRODUCTION This guide contains information that details methods for the collection, preservation and analysis of samples required for the monitoring of analytical parameters prescribed under the Regulation respecting the water quality of pools and other artificial reservoirs (Q-2, r.18.1.02) in order to ensure that water for bathers is safe, sanitary and stable. It is therefore important to ensure good cooperation between reservoir managers, samplers and the personnel assigned to laboratory analysis. According to the Regulation, the person responsible for a reservoir describes any owner or operator of a pool or other artificial reservoir concerned by the said regulation. This document has been prepared for all managers of reservoirs to explain the general preparations necessary and the safety measures that must be implemented at the time of sampling. It also outlines methods for sample collection in pools and other artificial reservoirs of water. The document contains a section concerning on-site analysis of parameters required for the chemical analysis of swimming water and a section relating to collection and preservation methods for samples intended for laboratory analysis. It also details recommended sample volumes, preservatives, types of containers and the timeframes that must be respected between sampling and analysis. DR-09-05 Page 5 of 12

1 GENERAL PRECAUTIONS The manner in which samples are collected has a direct impact on the quality of analytical findings. To minimize the risks of sample contamination by the sample collector and to ensure sample integrity, basic precautions must be taken to obtain a representative sample. Samples can become contaminated through careless sampling techniques. It is therefore the responsibility of the sample collector or of an artificial reservoir manager to ensure the quality of sample collection, preservation and suitable transportation of samples that are sent to a laboratory accredited by the Ministère du Développement durable, de l Environnement et des Parcs. The sample collector or of an artificial reservoir manager is also responsible for ensuring a representative sampling where on-site analyses are conducted. 2 ON-SITE ANALYSIS 2.1 Specific Precautions The following precautions are necessary to prevent sample contamination: closely follow the instructions provided by the manufacturer of the chemical test kits used at the sampling site; always use contaminant-free containers and where possible, prepare containers and testing equipment at sampling sites; keep an accurate record of each sample collected using the correct form; always use devices or instruments that have been calibrated at the required frequency (thermometer and ph-meter); reagents that are used for analysis must be kept in a clean, dry, well-ventilated and dark location until use; always take measurements with reagents in a suitable location. Avoid leaving reagents in prolonged sun exposure; seal reagent bottles correctly after use; never place wet fingers on reagent bottles; this may lead to inaccurate results; verify product expiry dates. Once the date indicated is past, you cannot be certain that results are reliable; discard expired products, in accordance with regulations in effect. 2.2 Preservation Methods The methods of preserving the analytical parameters prescribed in the Regulation respecting the water quality of pools and other artificial reservoirs are closely tied to analysis methods and are described in Table 1. DR-09-05 Page 7 of 12

Table 1: Preservation methods for chemical parameters (on-site analysis) Parameter Preservative * Container* Recommended volume (ml) Time between sample collection and analysis Alkalinity N P or G 10 30 minutes Hardness N P or G 10 30 minutes Total residual bromine N P or G 10 30 minutes Chloramines N P or G 10 30 minutes Free residual chlorine N P or G 10 30 minutes Total residual chlorine N P or G 10 30 minutes ph N P or G 10 2 hours Water temperature N P or G 125 3 minutes * See legend on page 12. 2.3 Sampling Method Samples intended for chemical analysis must be collected during normal operating hours, 15 to 30 cm below the surface of the water or, where a reservoir is less than 30 cm deep, halfway between the surface of the water and bottom of the reservoir. Samples must be collected in an area that is not very frequented by bathers at the time of sampling. It is also important to collect the sample in an area between the filtration system intake and water return. In the case of whirlpool baths, samples can be collected anywhere below the surface of the water. It is important to carefully follow the instructions provided by the manufacturer of the chemical test kits used. It is also essential that the hands of the person who is collecting the samples be extremely clean to prevent subsequent contamination (by sweat, chemical residues, etc.) when handling samples. The measuring cells of the kit must remain clean and transparent. Cells must be rinsed with the sample before their filling up and the level of liquid adjusted. They must then be wiped with a soft clean cloth before making colour comparisons, so that outer surfaces remain clean and dry. Always fill cells to the required level to prevent discrepancies in measurements. Page 8 of 12 DR-09-05

2.4 Analysis Methods 2.4.1. Water temperature For a water temperature reading, the following is required: collect a sample of water in a 125 ml wide-mouth glass or plastic bottle; dip a thermometer into the sample and wait at least 3 minutes for the temperature to stabilize; with the thermometer still in the sample, hold the bottle and thermometer at eye level and read the temperature; record the temperature to the nearest 0.5ºC (adequate marking). Use only calibrated thermometers. A water temperature reading can also be taken directly in the artificial reservoir. 2.4.2. Other Parameters It is possible to obtain different types of test kits for on-site analysis of chemical parameters (ph; free, total and combined residual chlorine; alkalinity; etc.). These kits are very useful for verifying the principal parameters that can be used to analyze water quality and therefore ensure that treatment systems are operating correctly. These kits generally include test containers, measuring cells and reactive products that help to determine concentrations of the products tested by using colorimetric comparators. Analyses must be conducted using reliable equipment and appropriate and not expired reagents. The reservoir manager must at least have a test kit capable of measuring free residual chlorine to between 0.2 mg/1 and 5.0 mg/1 with a precision of 0.2 mg/l. If using brome as a disinfectant, it is also necessary to have a test kit capable of measuring total brome to between 1.0 mg/l and 5.0 mg/ with a precision of 0.5 mg/l. Test kits must also be capable of measuring ph with a precision of 0.2 units, hardness and total alkalinity of the water with a precision of 10 mg/l. 3 LABORATORY ANALYSIS 3.1 Specific Precautions all samples sent for microbiological analyses must always be collected in sterile containers with wide openings provided by a laboratory accredited by the Ministère du Développement durable, de l Environnement et des Parcs; DR-09-05 Page 9 of 12

always begin a sampling campaign with microbiological samples, after, collect the chemical samples; always leave an air space of at least 2.5 cm between the surface of the liquid and the container lid. This helps to produce a homogenized sample for laboratory analysis; the necessary aseptic conditions must be respected when a sample is collected (e.g. avoid inserting fingers or other objects in the mouth or on the lid of the container and minimize exposure of the container to air at the time of sampling); samples should never be collected in unknown origin containers (always use laboratory-supplied containers); never rinse containers provided by a laboratory because some contain preservatives required for analysis; store sampling equipment in a clean and well-ventilated location; carefully close all containers tightly after sampling; where possible, precool samples in a refrigerator before sending them (particularly in summer); make a detailed record of all samples as soon as possible after sampling, using the appropriate forms, if samples are shipped to a laboratory; carefully pack samples to prevent breakage or leakage and use labeled shipping containers designed for sample shipment; use a reliable transport service to ensure sample integrity and delivery within the prescribed analytical timeframe. 3.2 Preservation Methods The preserving methods for the analytical parameters prescribed in the Regulation respecting the water quality of pools and other artificial reservoirs are closely tied to laboratory analysis methods. In fact, the desired sensitivity and quantification limits can be used to determine the volume and type of sample to be collected. The type of container and sample preservation technique are also determined on the basis of the analysis method. It is therefore vital to work in close cooperation with laboratory staff to obtain the proper additional information. In addition to the specific provisions detailed in Table 2, the following general considerations apply: from the moment samples are collected to the time they are received by a laboratory, all samples must be preserved at a temperature of approximately 4 C (use ice boxes or refrigerants) or chilled in an environment where an ambient temperature of approximately 4 C is maintained; if ice boxes are used, they must remain clean and, where possible, reserved exclusively for water analysis of pools and other artificial reservoirs; preservation and transportation are the responsibility of the sample collector or reservoir manager. Working in close cooperation with the laboratory is essential. Page 10 of 12 DR-09-05

Table 2: Preservation methods for microbiological and chemical parameters (laboratory analysis) Parameter Preservative* Container* Recommended volume (ml) Time between sample collection and analysis MICROBIOLOGY Escherichia coli ST3 PPS or GS 100 48 hours Pseudomonas aeruginosa ST3 PPS or GS 100 48 hours Staphylococcus aureus ST3 PPS or GS 100 48 hours Fecal coliforms ST3 PPS or GS 100 48 hours CHEMISTRY Turbidity N/A P or G 125 48 hours * See legend on page 12. 3.3 Sampling Method Samples sent for microbiological and turbidity analysis must be collected during normal operating hours, 15 to 30 cm below the surface of the water or where the reservoir is less than 30 cm deep, halfway between the surface of the water and the bottom of the reservoir. Samples must be collected in an area that is not very frequented by bathers at the time of collection and in an area between the filtration system intake and water return. In the case of whirlpool baths, samples can be collected anywhere below the surface of the water. The wide opening bottles must be filled to the rim, leaving an air space of at least 2.5 cm and the lid must be sealed immediately after collection. For water samples from an artificial reservoir destined for microbiological analysis, sampling containers contain a liquid reagent. This reagent neutralizes the residual disinfectant present in the water when a sample is collected. To preserve the reagent, ensure that you tip the container towards the bottom of the reservoir at a 45 angle in one motion. This preventive measure is necessary, otherwise results may be negatively distorted. It s also possible to collect sample by adding immediately and aseptically a sterile solid tablet of sodium thiosulfate in the sample. Samples for microbiological analysis must be collected with very particular attention paid to avoiding hand contamination, even when a collector has washed his or her hands before. If more than one sample is required, always begin with microbiological samples, and after with the chemical samples, to avoid dipping a microbiological analysis container in water that has been contaminated by the collector. DR-09-05 Page 11 of 12

LEGEND CONTAINERS P PPS G GS Bottles and lid linings are made of the following plastics: high- or low-density polyethylene, polypropylene, polystyrene, polyvinyl chloride or teflon Sterile polypropylene bottle Glass bottle PRESERVATIVES N ST3 OTHER N/A Sterile glass bottle No preservative required Sodium thiosulfate at a final concentration of 0.01 % (p/v) Not applicable Page 12 of 12 DR-09-05