Changing The Way Water Moves Ft Lauderdale, FL

Similar documents
AR No. # Efficient Irrigation

Education. V. Know How to Maintain an Efficient Pump. Pump Efficiency Tests. What is a Pump Test? Who Does the Pump Testing?

Digester Mixing Test at DeKalb Illinois Sanitary District WWTP. Preliminary Test Report October 2013

Booster Pump Fundamentals. By: Bill Baglot

FlowSet. Balancing Procedure

Experior as an Energy Savings Solution for Wastewater Lift Stations. Lisa Riles NA Marketing and Business Development Manager Xylem

Pumps and Pumping Stations

Pumping Plant Detailed Evaluation Worksheet

T Series. Self-Priming Centrifugal Pumps

Water & Wastewater Operation: Pipe Systems, System Curves, & Pump Curves

Specifying Pumps Why Do Pumps Fail.

Peerless Pump Company Handbook of Engineering Data

Rugged, reliable and efficient sump pumps... your assurance of a dry basement!

Reducing Energy Use and Costs for Pumping Water

Pump ED 101. Pump Selection for VFD Operation Part 3 Q / H Pump Down vs Level Control. Introduction. Pump Down vs Level Control

An Introduction to Pressure Sewers. Copyright Submersible Wastewater Pump Association (SWPA)

University Curriculum Development for Decentralized Wastewater Management

Contingency Planning for Temporary Pumping of Storm Water & Flooding Presented By: Ryan Booth

Sizing Guidelines for New or Replacement Sewage Pumps

SPECIFYING PUMPS WHY DO PUMPS FAIL.

AALSO Proficiency Program Level I, II & III

WASTEWATER PUMPING STATION INVENTORY

G2D Series Performance Data Discharge: 1-1/4 Solids: 1/4. Wholesale Products Page: JP10075SSD-1 Section: Performance Data Dated: January, 2011

HPGR200 2 HP. Capacity-U.S. G.P.M.

TECHNICAL MANUAL TEH-375A. Pump & System Curve Data for Centrifugal Pump Selection and Application

Pump System Optimization Checklist

SD/SW/VS50 SD50 SW50 VS50

The Islamic University of Gaza- Environmental Engineering Department Networks Design and Pumping Stations EENV Lecture 9: Pumping Station

Wastewater Treatment - Energy Saving Opportunity

Advanced Grit Removal Technology

Water and wastewater treatment operations

AALSO Summary of Formulas needed for Levels I, II and III.

Irrigation. Louisiana. Reducing Crawfish Pumping Costs

Energy Management Workshop

Successfully dosing pipe networks. Kevin Sherman, Ph.D., P.E., D.WRE Vice President of Engineering Clearstream Wastewater Systems, Inc.

WASTEWATER TREATMENT PLANT MASTER PLAN 6. BUSINESS CASE EVALUATION OF ALTERNATIVES

Fairfax Water Energy Savings Plan Welcome to Fairfax Water s Energy Saving Strategic Plan and Results for Year 2010

SK75/100. Performance Data TOTAL HEAD IN FEET HEAD-METERS 6 SK100 SK Liters/Second Capacity-U.S. G.P.M.

HUP. Performance Data. Wholesale Products Page: Section: Performance Data Dated: January RPM: 1550 Discharge: 1" Solids: 1/8" GPM: TDH:

Hydraulics Laboratory Experiment Report

Managing the Largest Extended Wet Weather Event on Record at TRA CRWS

Water Well Screens and Well Efficiencies Designing an Efficient Well

Case 7 Reciprocating Compressor

VIKING. Heavy-Duty, Foot-Mounted Sealless Internal Gear Pumps. Operating Range1: Nominal Flow Rates: Section 635 Page 635.

SPX50/SPX50H. Performance Data. Wholesale Products Page: Section: Performance Data Dated: October 2007

ENERGY EFFICIENY OF WATER DISTRIBUTION SYSTEMS

G2DT Series Performance Data Discharge: 1-1/4 Solids: 1/4. Wholesale Products Page: JP10074SSD-1 Section: Performance Data Dated: January, 2011

Session 2 Pump Selection. Mark Markham, P.E. Gresham, Smith and Partners September 14, 2017

September 22, Roy Hubbard HVAC Systems Technology

Pumps, Turbines, and Pipe Networks, part 2. Ch 11 Young

Pumped Outlets for Drainage Systems

Conflict Resolution: Pump & System Interaction. April 13, 2017

SHEF40. Performance Data. Wholesale Products Page: Section: Performance Data Dated: April 2002 Supersedes: January 2001

SK50. Performance Data TOTAL HEAD IN FEET HEAD-METERS 6 SK50 SK Liters/Second Capacity-U.S. G.P.M.

FAIRBANKS NIJHUIS SUBMERSIBLE SOLIDS HANDLING PUMPS.

Variable Speed Waste Water Pumping

SUBMERSIBLE SEWAGE EJECTOR

June 19, 2013 Annual OWEA Conference Steven Reese, P.E.

Energy Savings in Water and Wastewater Systems

When confronted with increasing peaking. Managing the deluge

FAIRBANKS NIJHUIS SUBMERSIBLE SOLIDS HANDLING PUMPS.

SUGGESTED SPECIFICATIONS

HYDROMATIC SKV50 SEWAGE EJECTOR PERFORMANCE DATA SKV50. Wholesale Products Page: RPM: 1650 Discharge: 2 Solids: 2.

EO = IHP= The efficiency of a pumping plant is calculated as follows:

SYSTEM ID: KY 10 NARRATIVE DESCRIPTION

Pump System Energy Saving Practices

PRELIMINARY WASTEWATER CAPACITY STUDY

Dominion Road Sewage Pumping Station and Force Main Replacement. Doug Pease, P. Eng. April 8, 2013 WEAO

flow rates filtration degrees water for cleaning minimum operating pressure micron less than 1% of the total flow

SYSTEM ID: KY 3 NARRATIVE DESCRIPTION

HYDROMATIC BV-40 SUBMERSIBLE NON-CLOG, SEWAGE EJECTOR

Enviro Voraxial Technology

Chapter 9 Sanitary Sewers

RESIDENTIAL SEPTIC PUMP SPREADSHEETS

Enviro Voraxial Technology

Appendix J Effluent Pump Station

VIKING. Heavy-Duty, Foot-Mounted Sealless Internal Gear Pumps. Operating Range1: Nominal Flow Rates: Section 635 Page 635.

& ACCESSORIES WASTEWATERTER PUMPSUMPS -EFFLUENT PUMPS -SEWAGE PUMPS -GRINDER PUMPS -ENGINEERED GRINDERS -ENGINEERED NON-CLOGS -ACCESSORISS

Piranha Agitator Slurry Pumps.75 hp to 75 hp

RAINWATER HARVESTING SYSTEMS

Close Coupled Sealless Pumps

SCRUBBER SUMP SYSTEM PROCESS DESCRIPTION Document No

RAINWATER HARVESTING SYSTEMS

SAF Filters. The automatic self-cleaning filter - suitable for more applications than ever.

Power Bills and Energy Efficiency for Irrigation. James Curran, Agricultural Resource Management

EC It Pays to Test Your Irrigation Pumping Plant

HOW TO SAVE COSTS AND IMPROVE SUSTAINABILITY WHILE REDUCING EFFLUENT NITROGEN

FLUID FLOW - PUMPS. Discharge Section. Section. Two main types of pumps: Positive Displacement pumps Centrifugal pumps.

NEBBinar: Managing Building Performance through Commissioning. March 28, 2013

Page Intentionally Left Blank

AQUAPROF BASIC AQUAPROF TOP ACTIVE SWITCH

A PERFORMANCE & FINANCIAL COMPRESSED AIR SYSTEM ANALYSIS

Sanitary Sewer Extensions, Lift Stations, and Force Mains Engineering Report Form. I. General Information. 1. Name of Facility:

Pressure Distribution Systems

SPECIFICATIONS - DETAILED PROVISIONS Section Progressing Cavity Pump C O N T E N T S

Surface Aeration System Modeling Using COMSOL

January 28, Innovative Technology: Development of the Self-cleaning. Wet-well. Robert Domkowski Engineering Consultant

SEWER SYSTEM MANAGEMENT PLAN (SSMP)

SUPPLEMENTAL MECHANICAL CORRECTION SHEET FOR SEWAGE EJECTORS AND SUMP PUMPS 2011 LAPC

PUMPING SOLUTIONS FOR LANDSCAPE

Transcription:

Changing The Way Water Moves Ft Lauderdale, FL 954-540-2863 www.globalgreenlifts.com

WELCOME TO THE ENERGY SAVING GREEN LIFT STATION DESIGN Introducing the wastewater lift station design that is sure to become the new industry standard. It s the first true breakthrough in lift station operating design since the traditional design was developed in the 1940 s In addition, this design far exceeds the efficiency promises of variable speed pumps for wastewater lift stations. In today s fiscal environment, governmental agencies are striving to: Identify funding sources for much needed Infrastructure Improvements 1 2 3 4 Reduce operating costs Reduce greenhouse gas and carbon footprint Identify processes that increase efficiency 100% 78% 65% 60% 58% We can help. This design uses our patented system control panel to accomplish each of these goals in a big way! Waste water Re-Pump stations retrofitted using our Green Lift Station Design will experience: Up to 73% energy cost savings over a 25 year project life (see case study Table 2) Up to 79% maintenance cost savings over the same project life (see case study Table 2) Up to 73% green house gas footprint reductions Up to 35% initial construction cost savings Pumps operating at an efficiency rate of 60 % vs. variable speed pump rates of 12 % These energy and maintenance cost savings pay off the initial investment in three years. Retrofitting traditional two pump lift stations accomplishes the same goals: Over 35% energy cost savings over a 20 year project life Up to 67% maintenance cost savings over the same project life Up to 35% green house gas footprint reductions

Traditional 2 Pump Lift Stations Efficient Green 3 Pump Lift Stations Pump horsepower (hp) must be large enough to handle the maximum waste water inflow resulting in: Pump hp selection is based on the pump rated efficiency curve and impellers are trimmed as needed resulting in: ø Low efficiency pump operation High efficiency pump operation ø Higher energy demand per start Lower energy demand per start The backup pump must be of the same hp capacity to move the waste water if the primary pump fails. Two high hp pumps often experience: The primary, backup and standby emergency pumps each have the same lowest possible hp with the backup and standby pumps assisting the primary pump: ø Periods of short cycling when the backup pump assists the primary pump due to the combined high hp gallons per minute (gpm) outflow rate Short cycling is eliminated through the use of our patented control panel and the operating sequence of the low hp pumps The primary pump turns on and off continuously resulting in: Primary pump runs continuously, backup pump turns on occasionally and the standby pump runs rarely: ø Loss of kinetic energy per stop Kinetic energy is maintained ø Heat buildup from motor stops No motor stop heat buildup ø Debris entering a stopped impeller causing excess resistant force on start ups With the primary pump running continuously, debris does not settle against impellers ø The motor burns out in a few years as a result of so many start/stops, the increased heat and the excess resistant force on start ups The life of all three motors is maximized for above 3 reasons and the monthly 3 pump operating sequence rotation made possible by our control panel

Energy Efficient Green 4 Pump Lift Stations outperform Traditional Re-Pump Lift Stations for the same reasons as those presented in the Traditional 2 Pump comparison above. Variable Speed Pumps have been introduced into the waste water lift station design with hopes of improved efficiency operation. However, Variable Speed Pumps: Cost more to purchase than single speed pumps Have been proven to be less energy efficient than single speed pumps in waste water lift stations by actual documented tests The following is an excerpt out of: Assessing variable speed pump efficiency in water distribution systems By Thomas Walski Use of variable speed pumping with storage: I have conducted numerous analyses comparing variable speed pumping to constant speed pump in systems for the relatively flat system head curves in water distribution systems (Walski, 2001, 2005, 2111; Walski, Bowdler and Wu, 2005). In each case, when a pump is selected to correctly match the system, the constant speed pump has a lower energy cost than the variable speed pump whether the storage is on the discharge side as in elevated water storage or on the suction side as in a wet well at a sewage pumping station. I have done these comparisons so many times that I jokingly refer to it as Walski s Law, The most efficient speed to run a variable speed pump is OFF. As long as there is storage to enable the pump to be turned off, it is best to run it at an efficient point and then turn it off. Running a variable speed pump at a low speed is inefficient. (Dr. Thomas Walski, Vice President of Engineering for Haestad Methods, was recently elected to the membership rank of Fellow by the American Society of Civil Engineers (ASCE). Dr. Walski is one of the most published and recognized water-resources modeling experts and educators in the world. He is a three-time winner of the best paper award in Distribution and Plant Operation for the Journal of the American Water Works Association and is the former editor of the Journal of Environmental Engineering.)

Selecting the most efficient pump to run a lift station Traditional 2 pump lift station pumps are selected so that the maximum inflow at any point in time can be moved out of the well by a single pump having a GPM rate equal or greater than the inflow GPM rate. Our green 3 pump lift stations utilize 3 pumps of equal GPM rates that are equal to the minimum inflow rate. Because the primary pump runs continuously and is assisted by the secondary pump when higher water inflow occurs, the two pumps operating together are able to accomplish the necessary discharge while minimizing the number of times the secondary pump turns on and off. The third pump is the emergency backup pump and it turns on during times of extraordinary inflows or if one of the other two pumps fail.

PERIODIC FILL-UPS AND PUMPING Traditional lift station with 2 pumps, 160 GPM/each, pump #1A cycles on and off as determined by flow and pump #2B is the backup Green lift station with 3 pumps, 80 GPM/each, pump #1A runs continuously, pump #2B runs periodically & pump #3C rarely runs/operating as stand-by

Manufacturers Determine Pump Life by the Number of On/Off Cycles Operating time of 160 GPM pump in the traditional 2 pump lift station; pump #1A cycles 17 times/24 hrs, pump #2B cycles 1 time/24 hrs Operating times of 80 GPM pumps in the green design 3 pump lift station; pump #1A cycles 1 time per month, pump #2B cycles 6/24 hrs and pump #3C cycles 1 time/24 hrs

Power demand on a utility company traditional 2 pump lift station Power demand on a utility company green design 3 pump lift station Traditional max = 107.6 amps vs Green max of 66.34 amps resulting in 38% reduction on power demand from the utility company by green designed station.

CASE STUDY We have performed a case study of an existing, traditional design, re-pump station. The study compared criteria and specifications (Table 1 below) of the traditional station with those of an energy efficient green designed station. Comparative costs of the construction of the traditional and green designed stations are presented in Table 2. Finally, the maintenance and energy cost savings of each designed station are provided in Table 3. TABLE 1 Item Description Traditional Design Green Design Wet Well Inner Diameter X Wall Thickness Depth 12 x1 30 12 x1 24 Pumps Average Operating Efficiency Maximum Inflow to Well Pump Rated Power Voltage Nominal Rated Amps Rush in Current (LRA) Rated Speed Impeller Diameter Pump Height Pump Wieght (With/Without Jacket) 12% 1750 GPM 85 HP 480 V 109 A 685 A 1185 RPM 15.875 56.5 2066/1900 63% 1750 GPM 30 HP 480 V 36 A 231 A 1755 RPM 5.9375 39.25 665/600 CRITERIA AND SPECIFICATIONS TRADITIONAL RE-PUMP STATION VS. GREEN DESIGN

Item Description Compiling Cost Items TABLE 2 TRADITIONAL GREEN DESIGN GREEN DESIGNED STATION SAVINGS Materials Labor Materials Labor Materials Labor Cost Of Construction Wet-Well 13/C.I. $29,767 $14,034 $23,054 $11,417 22.55% 18.65% Pumps & L 2/C.I. $144,426 $15,865 $73,316 $6,831 49.24% 56.94% Piping & Valves 12/C.I. $43,996 $22,000 $24,474 $12,237 44.37% 44.38% Electrical 16/C.I. $158,028 $62,070 $96,720 $38,795 38.80% 37.50% Emergency Generator 3/C.I. $70,820 $18,665 $52,480 $13,500 25.90% 27.67% Coffer Dam 9/C.I. $40,022 $16,000 $34,653 $16,000 13.42% 0.00% Excavation 11/C.I. $8,307 $8,667 $6,069 $6,429 26.94% 25.82% Dewatering 6/C.I. $6,400 $7,680 $4,800 $5,760 25.00% 25.00% Wet-Well Installation 20/C.I. $24,454 $23,077 $17,512 $17,727 28.39% 23.18% Totals $526,220 $188,058 $333,078 $128,696 36.70% 31.57& Total Cost Materials & Labor $714,278 $461,774 35.35% CONSTRUCTION COST COMPARISON TABLE 3 COST OF OPERA- TION (25 YRS) TRADITIONAL GREEN DESIGN GREEN DESIGNED STATION SAVINGS Maintenance $1,435,516 $300,482 79.07% Operating Energy Cost $6,072,525 $1,602,660 73.61% 25 YEAR PROJECT LIFE SAVINGS

This Page Left Blank Intentionally

Ft Lauderdale, FL 954-540-2863 www.globalgreenlifts.com