NSP SPECIALTY PRODUCTS Technical Data Sheet. NSP 120 High Performance Epoxy Coating

Similar documents
Carboguard 890 PRODUCT DATA SHEET SELECTION & SPECIFICATION DATA. Generic Type. Cycloaliphatic Amine Epoxy

PROTECTO-COAT EPG EPOXY PHENOLIC GLASS FLAKE COATING

PERFORMANCE, 100% SOLIDS,

max g/l (approx. 1.9 lb/gal) (aluminum) 31.2 m²/l for 25 µm (1251 ft²/us gal for 1.0 mils)

Hardener: at least 24 months when stored cool and dry

Note: Epoxies will characteristically chalk and fade with exposure to sunlight. Light colors are prone to ambering

Refer to Substrates & Surface Preparation.

TECHNICAL INFORMATION. 331 and PENNCOAT 340 LINING INSTALLATION. CES /01 Supersedes 04/00 PAGE 1 of 7 1. SURFACE PREPARATION. 1.

Refer to Substrates & Surface Preparation.

Application Guidelines for PPC Coatings Flooring

AMERSHIELD VOC. PRODUCT DATA SHEET April 20, 2015 DESCRIPTION. Low VOC Polyester Acrylic Polyurethane PRINCIPAL CHARACTERISTICS

AMERLOCK 2 AL. PRODUCT DATA SHEET September 12, 2018 (Revision of May 2, 2018) DESCRIPTION. Fast Dry Aluminum Epoxy Mastic Coating

Carboxane 950 Metallic

Aliphatic Acrylic-Polyester Polyurethane

Solventless two-component crosslinked epoxy

Measured in accordance with ASTM D 2697.

TL-250 Glass Flake Filled, Vinyl Ester Tank Lining System

Rust-Oleum Industrial Brands Specification

Sanitile 945 SL PRODUCT DATA SHEET SELECTION & SPECIFICATION DATA. Generic Type. 100% solids epoxy

Note: Epoxies will chalk and change color with exterior exposure. Colors are approximately and will tend to change over time.

STERI-FLEX SPECIFICATIONS FEATURES

20-30 mils ( microns) per coat mils ( microns) in two or more coats

Solventless, two-component, cross-linked epoxy. Epoxies lose gloss, discolour and eventually chalk in sunlight exposure.

Corlar 2.1 PR-P High Solids Productive Epoxy Primer

Sea~Barrier is the registered trademark of Altex Coatings Limited

Measured in accordance with ASTM D 2697.

GULF COAST PAINT MFG., INC

Corlar 2.1 PR-P High Solids Productive Epoxy Primer For Use With FG-040, FG-041 or FG-042 Activators

MEMBRANE 510/510R Low VOC Flexibilized, Urethane Membrane mils

two component high build amine adduct cured phenolic epoxy primer

TL-280 Sprayable Flake Glass Vinyl Ester Lining System

FLEXIBILIZED TROWEL APPLIED, GLASS

Heresite P-413 TECHNICAL DATA SHEET. P-413 Typical Properties 1 mil DFT) Our 50 years of coating history speaks for itself.

Ganicin 2.8 ZR-E Zinc-Rich Epoxy Primer

PPG HI-TEMP 1000 VS. PRODUCT DATA SHEET December 10, 2014 (Revision of June 30, 2014) DESCRIPTION

TL-225-NS Teflon Filled, Vinyl Ester Coating & Lining

Property Test/Standard Description. calculated US EPA method 24 (tested) (CARB(SCM)2007, SCAQMD rule 1113, Hong Kong)

AMERLOCK 2 / SIGMACOVER 2

Hardener: at least 24 months when stored cool and dry

PPG HI-TEMP 1000 V (AMERCOAT 873) PRODUCT DATA SHEET December 10, 2014 (Revision of June 30, 2014) DESCRIPTION

Rust-Oleum Industrial Brands Specification

OVERKOTE E-100 Epoxy Floor Coating Technical Data

Coronado Industrial Coatings Old County Road Edgewater, Florida FAX Line. Min Recoat:

PROTECTO-COAT 900/905

FORTEC % SOLIDS HIGH BUILD EPOXY COATING SYSTEM

Blome Sealant 55MT Flexible, Moisture-tolerant Epoxy Novolac Joint Sealant

PPG HI-TEMP PRODUCT DATA SHEET April 16, 2018 (Revision of September 5, 2017) DESCRIPTION

Blome Sealant 55MT Flexible, Moisture-tolerant Epoxy Novolac Joint Sealant

Easy to apply Nonflammable Low odor Castable Make excellent materials of construction

DIMETCOTE 9 VOC. PRODUCT DATA SHEET July 12, 2016 (Revision of August 7, 2015) DESCRIPTION. Inorganic Zinc Silicate Primer PRINCIPAL CHARACTERISTICS

One component, heat-resistant, universal silicone topcoat for use in elevated temperature systems. Replaces HI-TEMP 1000 V / VS / VHA

PROTECTO-FLEX 100XT. TROWEL APPLIED, GLASS REINFORCED, EPOXY LINING WITH NOVOLAC EPOXY TOPCOAT MILS ( mm)

PROTECTO-COAT 900/905

One-component, heat-resistant silicone acrylic topcoat primarily for the PPG HI-TEMP 1027 primer or the PPG HI-TEMP 222 G primer

AMERCOAT 235. PRODUCT DATA SHEET May 1, 2018 (Revision of October 26, 2016) DESCRIPTION. Two-component, multi-purpose phenalkamine epoxy

Property Test/Standard Description. US EPA method 24 (tested) (CARB(SCM)2007, SCAQMD rule 1113, Hong Kong)

PROTECTO-COAT 800/805

TL-250AR Abrasion Resistant, Glass Flake Filled, Vinyl Ester Tank Lining System

DIMETCOTE 9 H. PRODUCT DATA SHEET May 2, 2018 (Revision of August 7, 2015) DESCRIPTION. Inorganic Zinc Silicate Primer PRINCIPAL CHARACTERISTICS

Property Test/Standard Description. US EPA method 24 (tested) (CARB(SCM)2007, SCAQMD rule 1113, Hong Kong)

Property Test/Standard Description. calculated US EPA method 24 (tested) (CARB(SCM)2007, SCAQMD rule 1113, Hong Kong)

SIGMALINE PRODUCT DATA SHEET January 21, 2015 DESCRIPTION. Two-component, solvent-free, amine-cured phenolic epoxy coating

Property Test/Standard Description. US EPA method 24 (tested) (CARB(SCM)2007, SCAQMD rule 1113, Hong Kong)

A two component, 100% solids epoxy based intumescent coating. Aesthetics can be improved by trowel and back rolling.

PRODUCT GUIDE: ZINC-RICH COATINGS. Version:

1.4 kg/l (11.4 lb/us gal) Maximum 272 g/kg (Directive 1999/13/EC, SED) Maximum 420 g/l (3.5 lb/gal) To 650 C (1200 F) To 538 C (1000 F)

3M Scotchkote Liquid Epoxy Coating 323+

A/D Firefilm III PRODUCT DATA SHEET

Property Test/Standard Description. US EPA method 24 (tested) (CARB(SCM)2007, SCAQMD rule 1113, Hong Kong)

CORLAR 2.1 ST SATIN HIGH SOLIDS EPOXY MASTIC (formerly Corlar 25P )

DIMETCOTE 9 / SIGMAZINC 9

SECTION A. American Society for Testing and Materials (ASTM):

POLYMER CONCRETE 100 EPOXY POLYMER CONCRETE DILUTE ACIDS RESISTANCE

Tested in accordance with ISO , high expected durability in corrosivity category C5-I. Property Test/Standard Description

Ganicin 2.8 ZR- U Zinc-Rich Polyurethane Primer

EPILOX EPOXY BINDER TECHNICAL DATA SHEET. Multi-purpose High Performance Epoxy Binder System DESCRIPTION FEATURES AND BENEFITS

SECTION A. American Society for Testing and Materials (ASTM):

Property Test Method Typical Value

PROTECTO-FLEX 310. Corporate Offices 1818 Miller Parkway Streetsboro, OH FAX

100% Solids, Multi Functional, Pigmented High Build Epoxy Novolac Coating, For Wall & Ceiling Applications mils

Rust-Oleum Industrial Brands Specification

Approved. Property Test/Standard Description STANDARD GRADE. semi gloss (35-70) Flash point ISO 3679 Method 1

Approved. Property Test/Standard Description. matt (0-35) Flash point ISO 3679 Method F (29 C) calculated VOC-US/Hong Kong

POLYMER CONCRETE 800 NON-SHRINK VINYL ESTER POLYMER CONCRETE, CONCENTRATED HYDROFLUORIC ACID RESISTANCE

CC-1004 Ultra High Temperature Epoxy Adhesive

1.4 kg/l (11.4 lb/us gal) Maximum 295 g/kg (Directive 1999/13/EC, SED) Maximum 420 g/l (3.5 lb/gal) 50 to 63 μm (2.0 to 2.

Approved. Property Test/Standard Description. matt (0-35) Flash point ISO 3679 Method F (30 C) calculated VOC-US/Hong Kong

STERI-COAT P. Multi Functional, Pigmented High Build Epoxy Novolac Coating, For Wall & Ceiling Applications mils GREEN BUILDING FEATURES

(1 g/cm³ = 8.35 lb/us gal; 1 m²/l = 40.7 ft²/us gal) (data for mixed product)

Property Test/Standard Description. matt (0-35) Flash point ISO 3679 Method 1 35 C

SECTION A. American Society for Testing and Materials (ASTM):

Corlar LV PR 178 Series Epoxy Primer

Property Test/Standard Description. matt (0-35) Flash point ISO 3679 Method F (28 C) VOC-USA / VOC Hong Kong EPA Method 24

POLYMER ALLOY 1000/1000SF HIGH SOLIDS, MULTI-FUNCTIONAL, SEMI-SELF LEVELING OR SEEDED EPOXY FLOOR TOPPING

APPLICATION GUIDELINE FOR

SECTION A. American Society for Testing and Materials (ASTM):

Refer to Substrates & Surface Preparation.

Property Test/Standard Description. matt (0-35) Flash point ISO 3679 Method 1

PROTECTO-COAT 900FR/905FR FIRE RETARDANT CLASS A FLAKE FILLED, NOVOLAC VINYL ESTER COATING, MILS (1.0 mm)

3 Scotch-Weld TM. Epoxy Adhesive 2158 B/A. Technical Data December, 2009

Transcription:

Description: NSP 120, a two component, 100% solids, high build epoxy coating, offers excellent chemical, corrosion and abrasion resistance in severe industrial environments. This extremely versatile product features a unique 12-hour turnaround to service without force cure or specialized equipment. Intended Uses: Product Features: Approvals: Physical Data: Tank/Pipe Linings, Joining & Maintenance Repair, Waste Treatment, Wet Wells, Containment Areas, Walls, Machinery/Equipment, Structural Steel, Nuclear and Marine Applications. Moisture Tolerant- Cures under water - 12 hour Full Cure Ease of application brush, roller or spray Tenacious adhesion on properly prepared surfaces Tile like high gloss finish easy to clean and decontaminate Environmentally sound Accepted for use by the USDA in Federally Inspected Meat/Poultry Plants Accepted by the Canadian Food Inspection Agency in Registered Establishments Nuclear- Level 1 Areas Wet or Dry Wells Passed ANSI N101.2 Thermal Conductivity/ASTM 3911 for Design Basis Accident (DBA) & ASTM D-4082 Radiation Tolerance/Decontamination Testing per ASTM D4256/Chemical & Physical Exposure Test ASTM 3912, ANSI N5.12, ASTM D4060, Fire Testing ASTM E84 Also passed over marginally prepared steel Passes MIL-P-24380B Type II SH VOC Compliant Paint for Anchor Chain Type: Modified Epoxy Resin/Proprietary Blend Amine Adduct Hardener Color: White, Black, Tile Red, Light Gray. Safety Colors and other non-standard colors available upon request Components: Two Gloss: High Mixed Ratio: 2 Parts A (Resin): 1 Part B (Hardener) by volume Volume Solids: 100% - VOC 0 lbs/gal Pot Life @ 77F/25C: 30 minutes Page 1 of 5

Physical Data: Maximum Recommended Service Temperature: Dry Air Temp. 300F/149C Immersion: Deionized water 190F/88C Application Temperatures: 40-125 Deg. F. (10-52C) Note: Air and substrate temperatures - Elevated ambient and substrate temperatures during application (90-125 Deg. F) can affect the application properties in the following ways: speed up reaction time between Part A Resin and Part B Hardener therefore shortening pot life and decreasing drying times, lowering the viscosity of the product therefore decreasing sag resistance on a vertical surface. As long as the applicator knows pot life will be decreased and sag resistance (lower film build in one coat) on vertical surfaces will decrease, it will not have any negative effects on the cured film. Minimum Recoat Time @ 77F/25C: 3 hours Maximum Recoat Time @ 77F/25C: 48 hours Minimum Cure Time Full Service @ 77F/25C: 12 hours Sag @ 77F/25C: 16 mils Theoretical Coverage: 1604 sq/ft/gal/mil Allow for appropriate loss Maximum Thinner (if necessary): 20% by volume with NSP-T1 Thinner Packaging: Pre-portioned 3 Qt. Kit/ 3 Gal Kit/ 15 Gal Kit Physical Properties and Performance PROPERTY TEST METHOD RESULT Tensile Strength ASTM D638 5600 psi Compressive Strength ASTM D695 11700 psi Flexural Strength ASTM D790 8900 psi Adhesion to Concrete ASTM D4541 Substrate Failure Adhesion to Steel SSPC-SP10 ASTM D4541 >1200 psi Adhesion to Damp Concrete ASTM D4541 >350 psi Substrate Failure Tensile Elongation ASTM D638 5% Hardness, Shore D ASTM 2240 90 Abrasion Resistance ASTM D460, 1000 g Load 1000 cycles 37.7 mg Average Wt. Loss Flame Spread ASTM E84 Class A Flammability ASTM D635 Self Extinguishing Excellent chemical resistance Crude oil, sour gas, chlorine, bleach, Sulfuric Acid 0-70% Sodium Hydroxide 0-50% in immersion service, ambient temps. Page 2 of 5

Limitations: This product may not cure properly in temperatures below 40 F All epoxies will show chalking/yellowing on exterior exposures. Application of epoxy coatings in cool temperatures and high humidity can result in the formation of amine blush. Blush may appear as a milky, white, tacky residue on the surface of the cured coating and must be removed before the application of another coat. Intercoat adhesion problems may occur if blush is not removed. Surface Preparation: Steel Immersion Service: SSPC-SP10 Near White Blast Cleaning with 3.0-mil profile Non-Immersion Service: SSPC-SP6 Commercial Blast Cleaning with 2.0 mil profile Non-Immersion Service where a Commercial Blast Cleaning cannot be performed: Minimum requirement is SSPC-SP 2/SSPC-SP 3 Hand/Power Tool Cleaning or SSPC-SP7 Brush Off Blast Cleaning Concrete Concrete must be properly cured for a minimum of 28 days before application of coating. Surface must be entirely free of oil, grease, dirt, detergent, surface water, laitance, curing compounds, coatings or other contaminants that may interfere with adhesion. The concrete must be abrasive or water blasted to provide an anchor pattern (similar to 60-80 grit sandpaper min.) for adhesion. Final prepared surface should be clean and rough. Consult SSPC-SP13 Surface Preparation of Concrete. Mixing Instructions: This is a two-component system. Prior to mixing, components A Resin and B Hardener should be at room temperature (60-75 F/16-24C). Pour Part B Hardener into Part A Resin. Mix for 3 minutes using a Jiffy mixer head and a mechanical drill. To ensure complete mixing, scrape sides and bottom of container and continue mixing for an additional 1 or 2 minutes. Do not mix more material than can be applied within the pot life. DO NOT HAND MIX. Begin application immediately no induction time. Application: Air and surface temperature should be between 40-125F. Do not begin application if air, substrate or material temperature is below 40F or expected to fall below 40F within 12 hours of application. Do not begin application if dew point is within 5F/3C of the temperature. Variations in temperature can affect pot life and sag properties of this material. Do not exceed 20% by volume of thinner with NSP-T1 Thinner. NSP-T1 Thinner will not clean hoses or equipment adequately. Clean up using Acetone or other Ketone Solvent. For concrete surfaces, a primer coat of either NSP 100, 101 and 110 is strongly recommended. Method of Application: Brush, Phenolic Core Roller, Airless Spray Page 3 of 5

Recommended Equipment: Airless Spray Pump a minimum of 30:1 preferred 45:1 Tip Range -.023 to.027 Hose 3/8 I.D. if less than 50 ft. greater than 50 ft. use 1/2 (3500 psi High Pressure Spray Hose) Pressure (in) 90 cfm minimum @100 psi Pressure at the tip increase pressure slowly to 2000 psi and fine tune to achieve proper spray pattern. Check condition of fan at spray tip. During the first seconds of spraying, the material will often finger. Raise or lower pressure to adjust width. Periodically check pressure gauges while spraying. Knowing operating pressure will be useful in analyzing any changes to your spray pattern. Whip 3-5 and 1/4 ID Hose Take care to prevent mixed material from setting up in hoses. For optimum results, keep hose as short as possible, out of direct sunlight or away from heat. Purge immediately after spraying with Acetone or Ketone solvent. Cured material must be mechanically removed. Storage & Shelf Life: Warning & Safety: Shelf life is 12 months from the date of manufacture when stored in unopened containers and under recommended conditions. Material should be stored in a dry area under cover at temperatures between 45-95F/7-35C. It is recommended that the coating components be kept inside at a minimum of 60F/16C for 24 hours prior to start of application. Keep away from heat, flame and ignition sources. FOR INDUSTRIAL USE ONLY KEEP AWAY FROM CHILDREN Refer to Material Safety Data Sheet for NSP 120 Part A and B supplied with this product prior to application. MSDS may be obtained via web site at www.nsp-specialty.com, fax 910-235-3902 or by calling 800-248-8907. Use only with adequate ventilation and avoid breathing mist or vapors. Prevent contact with skin and eyes with protective clothing/impervious gloves and goggles. Do not take internally. Wash thoroughly after handling Page 4 of 5

Disclaimer & Limited Warranty: The information contained herein is intended to acquaint you with this product and is not intended to be exhaustive. This information is subject to modification from time to time without further notice. No agent, employee or representative of Seller has the authority to bind Seller to any oral affirmation, recommendation or representation of warranty unless contained in a written agreement signed by both Buyer and Seller. Seller expressly disclaims all other warranties, express or implied, including but not limited to any implied warranties of merchantability of fitness for a particular purpose or any other warranties relating to the condition of this product. Furthermore, Buyer acknowledges that it is familiar with and experienced in the use of industrial coating products and expressly assumes all responsibility resulting from or in any way connected with the possession, transportation, handling or use of this product, whether singly or in combination with other products. Sellers liability, with respect to any claim arising out of or relating to Buyer s purchase, possession or use of this product, is expressly limited to, at Seller s option, (i) replacement of the product, or (ii) return of the purchase price with transportation charges incurred by the Buyer, if material is proven defective. Any claim for defective product must be received in writing within one year from the date of shipment. Seller assumes no responsibility for incidental or consequential damages, or for any other damages related to any alleged nonconformity or defect in the product or to its purchase, possession or use. Page 5 of 5