WESTERN BAY OF PLENTY DISTRICT COUNCIL BUILDING CONSENT AUTHORITY

Similar documents
New Residential Building and Major Alterations / Additions

Building Consent Application Checklist RESIDENTIAL

Building Consent COMMERCIAL

User Guide for New and Altered Commercial Buildings

Application Checklist # 2 for New and Altered Commercial Buildings including Dairy Sheds

SIMPLE BUILDING CONSENTS

District of Ucluelet Building Permit Guide

CHECKSHEET: MULTI RESIDENTIAL, INDUSTRIAL OR COMMERCIAL BUILDINGS

Building consent application Pack 3 Solid fuel heating appliance

RESIDENTIAL BUILDING PLAN REQUIREMENTS

BROCHURE # 108 CONSTRUCTION PLAN COMPONENTS

The Homeowner s Building Application Checklist for Constructing a Residential Addition

CITY OF LAKE FOREST PARK BUILDING CHECKLIST FOR NEW CONSTRUCTION, ADDITION, AND REMODEL BUILDING PERMIT

ADDITIONS BUILDING AND ZONING REQUIREMENTS (REVISED 4/22/2008)

Private Bag 9023 Whangarei 0148 New Zealand T: WDC INFO F: W: E:

UCC Permit Application Procedures

MultiProof application form

Borough of Doylestown Building and Zoning Department

CITY OF HAGERSTOWN PLANNING & CODE ADMINISTRATION DEPARTMENT. Submittal Requirements

PENNSAFE BUILDING INSPECTION SERVICES LLC Deck and Roof Cross Section Submittal

RESIDENTIAL NEW CONSTRUCTION PLAN REVIEW CHECKLIST

CITY OF OAK CREEK SINGLE FAMILY & TWO-FAMILY CONSTRUCTION/PERMIT REQUIREMENTS

BUILDING PERMIT INFORMATION GUIDE FOR THE HOMEOWNER

Residential Building Plans

PENNSAFE BUILDING INSPECTION SERVICES LLC PERMIT APPLICATION

City of San Pablo Community Development Department Building Inspection Division Plan Review & Permit Requirements

Building Consent BC161669

GENERAL BUILDING CODE AND ZONING REQUIREMENTS: Post and spread footings shall be designed and constructed below the minimum frost depth of 42 inches

For Council Use. Building Category R1 R2 R3. Approving Officer. Note: PIM (Appln vetted and lodged) Water Services Add Inspect *

Two complete sets of plans that are legible and drawn to conventional scale are required to be submitted with the Building Permit Application Form.

COMMERCIAL OR RESIDENTIAL NEW BUILDINGS, REMODELS AND ADDITIONS

THE BUILDING CONSENT PROCESS

SFR SUBMITTAL REQUIREMENTS

10/23/2011. Plan Examination. Plan ExaminationPurpose. Catch problems in advance of construction.

One & Two Family Residential ADDITIONS

Minimum Residential Plan Submittal Requirements


FIRST TIME! GETTING IT RIGHT YOUR GUIDE TO THE BUILDING INSPECTION PROCESS

* RESIDENTIAL PLAN REVIEW *

HOW TO OBTAIN A BUILDING PERMIT

RESIDENTIAL CONSTRUCTION New Dwellings and Additions

SOLID FUEL HEATER APPLICATION FOR PROJECT INFORMATION MEMORANDUM AND /OR BUILDING CONSENT Section 33 or 45, Building Act 2004

PO Box 747, Gisborne 4040 Phone: (06) Freephone: Fax (06)

HOUSE REPAIRS & RENOVATIONS BUILDING PERMIT REQUIREMENTS

One and Two Family Additions

2012 Code Update Training

BUILDING DIVISION 120 Malabar Road, S.E., Palm Bay, FL Phone: (321) Fax: (321)

INFORMATIONAL HANDOUT FOR FINISHING A BASEMENT

RBW does not include building work for which a building consent is not required.

One & Two Family Residential NEW CONSTRUCTION Plan Review Checklist

11/09/2018 LBP licence classes

GETTING IT RIGHT FIRST TIME! YOUR GUIDE TO THE BUILDING INSPECTION PROCESS

Inspection requests submitted by 2:30pm will be scheduled for the following business day unless otherwise requested.

Screen & 3-Season Porches

City of Santa Monica Building and Safety Division

SCREEN PORCHES 101 DEVELOPMENT RESOURCES, INC Permit Requirements

INDIANA COUNTY Office of Planning and Development 801 Water Street Indiana, PA (724) Fax (724)

Building Standards Department. Guide to Building Permits Understanding the Different Building Permit Types and their Submission Requirements

MINIMUM PLAN INFORMATION REQUIRED FOR A BUILDING PERMIT

Township Of Blandford-Blenheim Permit Guide

Guide to Building Inspections

ARTICLE 12 INTERNATIONAL RESIDENTIAL CODE 2012 International Residential Code Modification Summary (Statutory Authority: 1976 Code Section )

Proposed Residence for Trade Mark Developments. 17 Drake Crescent, Te Awa Estate, Napier

Administrative Changes

CARPENTRY WORKPLACE TASKS - CHECK LIST (Note: for employer reference only)

*FOR RESIDENTIAL PROJECTS, CALL JACK CARNS AT *FOR COMMERCIAL PROJECTS, CALL BRIAN WRUBLE AT

Lonsdale Building Inspections Department 415 Central Street W. PO Box 357 Lonsdale, MN (507) fax (507)

CALIFORNIA COMMERCIAL BUILDING INSPECTOR CONTENT OUTLINE 01. GENERAL ADMINISTRATION 6% Project Administration 1%

CONSTRUCTION DOCUMENTS CHECKLIST for the 2012 Michigan Building Code Including Building Permit Application Checklist

MultiProof -design compliance with Building Code clauses

0103 Plan Reading 4% Read plans to verify the project conforms with the code, approved plans, and construction documents.

PENNSAFE BUILDING INSPECTION SERVICES LLC NEW COMMERCIAL BUILDING UCC PLAN REVIEW HANDOUT AND CHECKLIST

Bituminous Roofing Underlay & Valley Guard

BUILDING PERMIT APPLICATION

Residential Building Permits

TOWN OF FRANCESTOWN BUILDING/CODE ENFORCEMENT 27 MAIN STREET P.O. BOX 5 FRANCESTOWN, NEW HAMPSHIRE Building Permit Application Guide

CALIFORNIA BUILDING PLANS EXAMINER CONTENT OUTLINE 01. GENERAL ADMINISTRATION 3 % Project Administration 3%

#402 New Residential Submittal Checklist

INSPECTION TIMING CHECKLIST FOR RESIDENTIAL FRAME BUILDING PRIOR TO INSPECTION REQUEST

wall underlay Product BRANZ APPRAISAL No. 695 (2010) Scope Thermakraft Industries (NZ) Ltd PO Box Botany Manukau 2163 Auckland

Bituminous Building Paper

CITY OF SASKATOON COUNCIL POLICY

1420 Miner Street Des Plaines, IL P: desplaines.org COMMERCIAL STRUCTURES (INCLUDING ALTERATIONS AND ADDITIONS)

RESIDENTIAL BUILDING PERMIT GUIDE FOR MULTI-FAMILY DWELLINGS

Fees and Permit requirements are regulated by the Township s Building By-law

Proud of its Heritage, Preparing for its Future

Roof Design Information Request CLIENT GUIDE

TOWN OF ROTTERDAM RESIDENTIAL BUILDING PERMIT APPLICATION Ext. 395 Needed to Obtain Permit:

City of Walnut Creek Development Review Services 1666 N. Main Street, Walnut Creek, CA (925) phone (925) fax

Determination 2010/052 Refusal to issue a code compliance certificate for a 6-year old house at 103 Karewa Parade, Papamoa

City of DuBois PERMIT APPLICATION P. O. Box 408, 16 West Scribner Ave - DuBois, PA Phone: Fax:

WATERGATE-PLUS 295 FIRE RETARDANT WALL UNDERLAY. Product. Scope. Appraisal No. 695 [2017]

*FOR RESIDENTIAL PROJECTS, CALL JACK CARNS AT *FOR COMMERCIAL PROJECTS, CALL BRIAN WRUBLE AT

2003 International Residential Building Code

Building Guide. Colorado Chapter of the International Code Council

City of Hughson Building Safety Division 7018 Pine Street Hughson, CA (209)

SUBMITTAL REQUIREMENTS FOR SINGLE FAMILY DWELLINGS

ORDINANCE. APPROVED EMERGENCY: (Yes) (No) VETOED: Date

PERMIT APPLICATION CHECKLIST Municipal Address, Phone & Fax NONRESIDENTIAL

Transcription:

WESTERN BAY OF PLENTY DISTRICT COUNCIL BUILDING CONSENT AUTHORITY Building Consent Checklist - Residential Dwelling (consent application for single residential private dwelling, new or alteration works; or any work related to a single private dwelling building type) General notes: The checklist is designed to ensure applicants know up front what information is required for your building consent application and to assist you in preparation of your consent application. It is intended to help avoiding delays in processing and ensure your application is processed in a timely manner. Please ensure you read the checklist and answer all questions. All items on this checklist must be circled to show that they are either provided or are not applicable to your project N/A. It is highly recommended that the person completing the checklist has an understanding of the technical information supplied with the building consent application and has the ability to identify the information requested on the checklist. Later additional information may be requested during the processing of your building consent to confirm compliance with the Building Act, Building Code, District Plan and any other relevant legislation. Processing time will be suspended until further information is received. Documentation must cover all aspects identified in this lodgement checklist. For application submitted in hard copies, all applications must be accompanied by 2 x comprehensive sets of documentation. Standard of documentation Section 7 of the Building Act defines plans and specifications as the drawings, specifications and other documents according to which a building is to be constructed, altered, demolished or removed. Documentation is required to be of a high, professional standard. Refer to the Department of Building and Housing publication Guide to applying for a building consent for a copy visit https://www.building.govt.nz/ Drawings must be produced to scale on white A3, A2 or A1 paper. Minimum font size of 10. Applications supported by a producer statement (PS): If an application is supported by a producer statement, the architectural plans must be counter-signed by the design specialist (i.e. engineer) confirming design details unless the drawings are provided by the specialist. Customer Use (circle selection) DESCRIPTION GENERAL REQUIREMENTS Building Consent Application Form 2 completed in full Proof of ownership supplied, i.e. Agreement for sale and purchase, certificate of title (less than, license to occupy/occupation order from the Maori Land Court. Project description is accurate and describes all work involved on the project All drawings must meet the minimum requirements of the technical drawings standard AS/NZS1100 with a minimum font size of Microsoft word text size 10. All documents have been drawn to a recognised metric scale and noted All documents including photocopies are legible and must have at least 10mm margin on all outer edges with no information in them. All plans are titled and dated E2 risk matrix (refer to elevations section) H1 compliance calculations Bracing calculations (refer to foundation plan and bracing plan section) A704187 14 April 2014 Version 2 Page 1

FORM 2A CERTIFICATE OF DESIGN WORK The designer has provided a Certificate of design work for restricted building work? The Engineer has provided a Certificate of design work for restricted building work? Have all fields on the Certificate of design work been fully completed? Is there a waiver or modification? Has the declaration been completed fully (no change to wording) and signed personally by the licensed building practitioner? SITE PLAN (SCALE 1:100 FOR URBAN AREAS AND 1:200 / 1:500 FOR RURAL AREAS) Street address, legal description, north point, site area, wind, exposure and earthquake zone Boundary bearings and dimensions, easements, building line restrictions Levels, contours, datum identified with finished floor levels. Proposed cut and fill / existing and proposed retaining clearly identified. Existing and proposed buildings clearly identified. At least two dimensions from the extremity of the building (i.e. guttering) to boundary. If more than one dwelling on the site dimension to other buildings. Points identified on boundaries where overshadowing is taken from NB: if encroaching into overshadowing, Written approval of affected person form to be provide along with signed and dated elevations and site plan Crossings / driveways shown, existing and proposed vehicle access. If building is under or near high voltage transmission lines, show transmission plan area. PLUMBING & DRAINAGE (MAY BE INCLUDED ON SITE PLAN IF SCALE 1:100) Position of existing council waste water and storm water sewers and connections Position of proposed/existing waste water and stormwater drains On-site waste water system with reserve area in accordance to BOPRC On-site Effluent Treatment Regional Plan 2006 or BOPRC approved effluent disposal system Details of storm water disposal, e.g., council connection, soak holes, detention tanks? Downpipe sizes and positions shown Sanitary fixtures shown with waste pipe sizes and gradients. Schematic provided for more than one level Existing or proposed potable water supply e.g. council supply, water tank (including filtration), bore or spring. FLOOR PLAN (SCALE 1:100 OR 1:50) Floor layout and function of each room identified (all levels) shown. For additions and alterations, the existing shall be shown separately to the proposed and to the same scale for comparison Framing layout fully dimensioned. Show and dimension all doors and windows. Lintels /beam sizes and grade. Lintel fixing types on plan. Outside the scope of NZ3604:2011, proprietary system identified with calculations etc Plumbing fixtures shown, shower type identified, if tiled; membrane specifications supplied, relevant E3 details provided (floor to wall, timber floor support, shower floor gradients etc) Location of internal HWC position with details regarding seismic restraints supplied Ventilation to enclosed spaces (e.g. laundry, internal WC etc.) A704187 14 April 2014 Version 2 Page 2

Internal stairs with dimensions for tread & riser, height of and position of handrail Position of smoke detectors, fire walls indicated? External stairs, handrails, decks and balustrades shown (refer to foundation plan for deck) FOUNDATION PLAN (SCALE 1:100 OR 1:50) Slab construction, footing location, steel reinforcing and mesh type, slab thickness and strength, slab thickenings, rebates, shrinkage control cuts and free joints, slab dimensions Specific Engineered Design (e.g. ribraft) provide engineers design, calculations and PS1 (refer to specific engineered design section) Timber floor Pile layout, footing sizes, pile type, size, treatment, bearer and joist treatment, grade, size and max span of members. Dimensions showing overalls and centres to supports. Bracing elements identified and details provided Foundation bracing calculations provided with correct wind zone & earthquake zone Dimensions reflect plans, i.e. roof height to apex, area etc.? BRACING PLAN (SCALE 1:100 OF 1:50) Bracing details type, length position detailed Bracing calculations provided, correct wind zone & earthquake zone Dimensions reflect plans, i.e. roof height to apex, area etc. ELEVATIONS (SCALE 1:100 OR 1:50) Elevations for each external wall with E2 risk matrix for each face provided District plan daylighting / overshadowing shown and corresponds with positions indicated on site plan (if relevant) Existing and proposed ground levels indicated, existing and proposed retaining shown, cut and batter shown? Ground levels, finished floor levels If addition, area of addition clearly identified All cladding clearly identified (proposed and existing) Control joints if applicable Roof pitch, height from ground to apex, heights of chimneys. Doors and windows showing opening sashes, obscure and safety glass indicated Sub-floor ventilation and access shown External stairs, handrails deck and balustrades shown if applicable CROSS SECTIONS (SCALE 1:50 OR BETTER) & DETAILS (1:10 OR 1:5) A minimum of two cross sections, one through the width and one through the length. Cross- sections clearly show construction methods (stud sizes, stud height, timber treatment, spacing, grade, insulation, lining and cladding) any fire rated systems noted Finished floor levels to ground levels, retaining walls, proximity to services shown Detail markers showing cross referencing to details, details to be numbered and sheet / page number noted. Foundation sizes with reinforcing steel, bottom plate fixing/cladding overhang. Differing finished floor levels detail provided Penetrations through exterior walls and roofs detail shown Window & door details shown head/sill/jamb Cladding type, wall underlay, cavity & battens, cladding junctions (horizontal and vertical), external and internal A704187 14 April 2014 Version 2 Page 3

corners, existing to new. Does the cladding require control joints Structural elements, junctions & fixings. Wall to roof junctions / soffit detail / parapet detail/beam to wall Insulation shown and R value noted on cross section. Roof cladding materials, pitch, underlay noted, barge, ridge and valley details with flashing dimensions provided Bottom plate and stud to top plate fixings identified Wet area details shown, shower type specified, if tiled shower are waterproofing membrane technical specifications included Ceiling lining type, thickness and method of support shown, size, spacing, treatment etc. All external elements e.g. stairs and handrails, decks and balustrades, barriers. Special engineer design required where detail does not comply with NZBC B1/AS2. Refer to SED section. ROOF PLAN & ROOF FRAMING PLAN (SCALE 1:100 OF 1:50) Buildable truss layout by certified truss manufacturer and PS1 supplied, correct wind zone Roof bracing indicated, overhangs dimensioned, differing pitches identified Rafters size, treatment, gauge, spacing noted Truss to top plate fixings Purlin to truss fixings Location of internal gutters, rain water heads and DP s shown SPECIFIC ENGINEERED DESIGN (SED) Engineer s calculations, drawings and a PS1 signed and dated within the last two years Plans signed by the engineer if supported by a producer statement (PS1) All Engineer s details been transferred onto the architectural plans Inspection regime by engineer required to ensure construction work of specific design element will comply with the engineer s design DEMOLITION / REMOVAL All existing buildings to be removed or demolished shown on site plan Identify services to be capped and sealed inside boundary RELOCATION/RELOCATED BUILDING Complete checklists for General requirements, Form 2a, Site plan, Plumbing and drainage, Floor plan, Foundation plan, Elevations (photographs can be used for rural sites) If work outside of the relocatable footprint is proposed complete the relevant additional checklist sections. Supporting document required to verify how the existing building will be suitable and that existing condition of the building will be fit for purpose at the new location; taking into account the local and environmental condition of the site. Refer also to Guidance notes - Moving or relocating a building Prepared scope of work for improvement, upgrade work or remedial works to reinstate the building to its new location and foundation A704187 14 April 2014 Version 2 Page 4

SWIMMING/SPA POOL Pool specifications, i.e. type, brand, installation instructions etc. Engineering calculations / producer statements provided for structural design elements (refer to SED section) Complete General and Site plan checklist with location of proposed pool with immediate pool area specified (ie Pool isolated) Position of pool fencing including any gates showing opening direction, backwash water disposal method and back flow prevention type and location. Elevations and a cross-section through pool if installed on a sloping site Fencing specification i.e. materials, height, ground clearances, gate and latching details etc. If building used as part of fencing: Floor plan indicating location and opening projection of all doors opening into pool area Construction details and type of self-closing/self latching devices for all doors leading into pool area Elevations indicating any windows less than 1.2m in height from floor level opening into pool area and details of locking mechanisms i.e. restrictors If boundary fence is to be used as part of the pool fencing: Photos showing all intersecting fences, note: no climbable intersecting fences, rails etc. permitted. Photos showing both sides of fence, note: no climbable projections permitted within 1.2m of fence (i.e. tress, sheds etc.) Cross section showing details of fencing (height, openings, materials etc.) For further guidance and information on the Fencing of Swimming Pools Act 1987 refer http://www.dbh.govt.nz/fospa-index SOLID FUEL HEATER APPLIANCE If the installation of a solid fuel heater is part of this application please complete the checklist from the Solid Fuel heater checklist. A704187 14 April 2014 Version 2 Page 5