ACOUSTIC EXAMINATION OF EPOXY-GLASS INSULATOR MATERIAL P. RANACHOWSKI, Z. RANACHOWSKI, F. REJMUND J. STANKIEWICZ

Similar documents
(2) Polish Academy of Sciences Świętokrzyska 21, Warszawa, Poland

Polish Academy of Sciences Institute of Fundamental Technological Research ( Warszawa, Świętokrzyska 21, Poland)

Comparison of Acoustic Emission and Structure Degradation in Compressed Porcelain and Corundum Materials

Composite Insulator Components

Module 8: Composite Testing Lecture 36: Quality Assessment and Physical Properties. Introduction. The Lecture Contains

A R C H I V E S O F M E T A L L U R G Y A N D M A T E R I A L S Volume Issue 4 DOI: /v

Design a surge arrester performs in service

ACOUSTICAL AND DYNAMIC MECHANICAL CHARACTERIZATION OF FIBER-MATRIX INTERFACE BONDS IN CERAMIC COMPOSITES

Outdoor High Voltage Non-Ceramic Insulators

Monitoring Of Adhesive Cure Process and Following Evaluation of Adhesive Joint Structure by Acoustic Techniques

PI Electrical Equipment - tourse PI 30.2 INSULATION. On completion of this module the student will be able to:

Nondestructive Evaluation of Natural Fiber Reinforced Composites: Material Properties and their Deterioration

Application of ultrasonic testing to steel-concrete composite structures

Piezoelectric ceramics test for crack detection

6C-001 High-Voltage Pin-Type Insulator

Effect of Metal Ring on the Field Distribution of Outdoor Polymeric Insulator

OPTICAL FIBER SYSTEM FOR AE MONITORING OF HIGH TEMPERA- TURE DAMAGE OF STAINLESS STEEL TUBING

Metallurgical Defect: Manufacturing of a Reference Specimen for NDE Studies

Critical design, testing and manufacturing features for the selection of high quality composite insulators for transmission overhead lines

ACOUSTIC EMISSION BEHAVIOR OF FAILURE PROCESSES OF GLASS-FIBER LAMINATES UNDER COMPLEX STATE OF LOADING

NEXTREMA. Glass-ceramics engineered and designed for extreme conditions

Effect of Materials Design on Properties of Porcelain Insulators

APPLICATION OF THE ROD AND TORSION WAVES FOR TESTING THE EXTENDED OBJECTS OF OIL-EXTRACTING INDUSTRY

PART I PERFORMANCE OF MATERIALS IN SERVICE. Materials and Process Selection for Engineering Design: Mahmoud Farag

Reading assignment. Nondestructive evaluation (NDE) Nondestructive testing (NDT) Penetrant. Conventional NDE mthods. Topic 7

Introduction to Composites

COMBINED INVESTIGATION OF EDDY CURRENT AND ULTRASONIC

HIGH VOLTAGE INSULATORS. By JP Holtzhausen. Glass. Bushings & hollow core insulators. Cap & pin insulators

USE OF AE FOR CHARACTERIZATION OF DAMAGE MECHANISMS IN COMPOSITE ACCUMULATOR

Influence of the Al 2 O 3 Solid Phase on the Kinetics of Binding Ceramic Moulds

CHAPTER 6 HIGH VOLTAGE ELECTRICAL TESTING RESULTS

STP772-EB/Jun Index

ADHESIVE CURE MONITORING WITH ACOUSTIC METHOD

W.J. Murri, B.W. Sermon, R.N. Andersen L.A. Martinez, E.J. VanderHeiden, and C.A. Garner

EELE408 Photovoltaics Lecture 18 Photovoltaic Arrays & Modules

DAMAGE EVALUATION OF SMART CFRP-PIEZOCERAMIC-MATERIALS USING NON-DESTRUCTIVE METHODS

ELASTIC ANISOTROPY IN PARTICLE/FIBER REINFORCED ALUMINUM METAL MATRIX COMPOSITES. B.Grelsson and K.Salama

Electronics materials - Stress and its effect on materials

INVESTIGATIONS ON RELATIONSHIP BETWEEN POROSITY AND ULTRASONIC ATTENUATION COEFFICIENT IN CFRP LAMINATES BASED ON RMVM

Comparison of effects of Various Contaminations on SiR insulators

Composite Materials. Metal matrix composites

New designed XLPE-insulated cables substituting paper-insulated pipe type cables

Research methodology for the life evaluation of Hollow polymer insulators for High Voltage Applications

WHITE PAPER The Criticality of Proactive Maintenance on Isolated Phase Bus Duct Systems

Composite Materials. In depth look

Diagnostic Techniques of Composite Insulators

Saint Petersburg State University, 7/9 Universitetskaya nab., St. Petersburg, Russia 2

Peterhof, St. Petersburg, , Russian Federation. Nan Gang District, Harbin, , China. a

PS2: Lifetime management, deterioration and ageing of substation equipment

Technologies for reliable titanium alloy forgings focusing on ultrasonic inspection in aerospace industry

Fatigue Crack Initiation and Propagation in Lotus-Type Porous Copper

MSE 3143 Ceramic Materials


Using Fractography to Investigate Causes of Material Failure in Sulfone Polymers

Advanced Manufacturing Choices

DETECTION OF INCLINED CRACKS INSIDE CONCRETE STRUCTURES BY ULTRASONIC SAFT

ASSESSMENT OF DAMAGE PROCESSES IN REINFORCED REACTIVE POWDER CONCRETE (RPC) BEAMS BY ACOUSTIC EMISSION PROCEDURE

SYSTEMIC ANALYSIS FOR THE SELECTION OF ANODE BAKING FURNACE REFRACTORIES

A REVIEW ON FAULT ANALYSIS IN UNDERGROUND CABLES

QUANTITATIVE NONDESTRUCTIVE EVALUATION OF ADHESIVE BOND STRENGTH

Oil tempered SiCrVNi-alloyed ultra-high tensile valve spring wire for surface nitriding

TUBE CRACK DETECTION BY AE MONITORING OF DEEP DRAWING OPERATIONS IN THE AUTOMOTIVE INDUSTRY B. Bisiaux, T. Wartel 1, A. Proust. D.

ACOUSTIC EMISSION COMPARATIVE STUDY OF CARBON/EPOXY COMPOSITES UNDER LOAD

Oil tempered SiCrVMo-alloyed ultra-high tensile valve spring wire for surface nitriding

The research of ceramic materials for applications in the glass industry including microwave heating techniques

COMPOSITE MATERIALS. Asst. Prof. Dr. Ayşe KALEMTAŞ

Production line for glass fiber reinforced plastic rebar

Capstone C O N S U L T A N T S

Materials Science and Engineering: An Introduction

Nondestructive Testing

A Modeling Platform for Ultrasonic Immersion Testing of Polycrystalline Materials with Flaws

Electromechanical impedance method for assessment of adhesive bonds of CFRP at the production and repair stage

Abstract. 1. Introduction. 2. Testing methodology. Early stage cavitation erosion within ceramics An experimental investigation

SINGLE CRYSTAL SAPPHIRE

Study of Water Effect on some Specimens of Epoxy Composites Reinforced with Different Types of Fibers

Polluted Outdoor Insulators Maintenance and Washing

Effects of fibre content on mechanical properties and fracture behaviour of short carbon fibre reinforced geopolymer matrix composites

TRANSMISSION & DISTRIBUTION SILICONE INSULATORS InterPhase Spacers 15 kv to 400 kv

Investigation of leakage current flow through wooden poles structures on overhead distribution system

Evaluation of the Destruction Process of Metal-Composite Cylinders with Use of Acoustic Emission Method

Haseeb Ullah Khan Jatoi Department of Chemical Engineering UET Lahore

Notes Changed note Date. 1 (A) Changed template 09 / 07 / 2008

Advanced Inspection of Steel Elements

Brittle Fracture Resistance Test on Composite Core of ACCC/TW

Novel non-destructive methods for wood

Examples of composites. Composited in nature wood bones. Syntetic composites Plywood Paper Metallic alloys Reinforced concrete

EXPERIMENTAL INVESTIGATION OF EFFECT OF UV RADIATION ON FLASHOVER VOLTAGE OF POLYMERIC INSULATORS WITH AND WITHOUT CONTAMINATION

THE MICROSTRUCTURE AND WEIBULL STATISTIC OF ALUMINA-WC PARTICULATE COMPOSITES

THERMOFIT SCL TUBING Polyolefin, Selectively Crosslinked, Semirigid, Heat Shrinkable

Manufacturing and Application of Cage Design High Voltage Metal Oxide Surge Arresters

DYNAMIC MODULUS OF SYNTACTIC FOAM AND PARTICULATE COMPOSITE CORE - A NON DESTRUCTIVE APPROACH

Metals are generally ductile because the structure consists of close-packed layers of

Contact Laser Ultrasonic Evaluation (CLUE) of Aerospace Materials and Parts

Electric field analysis of 132kV EPDM insulator and correlation with ageing features

Pins Insulator. Composite/Polymers Insulators

Module 5 Design for Reliability and Quality. IIT, Bombay

RUBBER AND RUBBER MASTIC

Structural Composite Materials

SECTION 7. ULTRASONIC INSPECTION

Collaborative Working Group on Hybrid Processes

Transcription:

ARCHIVES OF ACOUSTICS 30, 1, 121 130 (2005) ACOUSTIC EXAMINATION OF EPOXY-GLASS INSULATOR MATERIAL P. RANACHOWSKI, Z. RANACHOWSKI, F. REJMUND Institute of Fundamental Technological Research Polish Academy of Sciences Świętokrzyska 21, 00-049 Warszawa, Poland e-mail: freymund@ippt.gov.pl J. STANKIEWICZ Electrotechnical Institute Division of Electrotechnology and Materials Science Skłodowskiej-Curie 55/61, 50-369 Wrocław, Poland e-mail: jstank@iel.wroc.pl (received March 2, 2004; accepted September 23, 2004) Ultrasonic, microscopic and acoustic emission (AE) methods were applied to investigate the microstructure of composite rods, used as a carrying element of the medium voltage insulators. Such features of material structure as homogeneity level and the appearance of defects were discussed. The research was aimed at determining the influence of the technology of epoxy-glass fabrication on quality parameters of the insulator rods. The results of acoustic testing were compared with the effects of microscopic investigation. Key words: composite insulator, epoxy-glass material, nondestructive ultrasonic measurements, acoustic emission. 1. Introduction Electrotechnical porcelain is considered as the most commonly applied in the industry high-voltage insulating material. The variety of its advantages makes the porcelain one of the leading materials applied in engineering. The essential properties of this material are its high resistance to corrosion and to thermal damage, high electrical resistance and mechanical strength at acceptable values of density. The parameters stated above, in correlation with the practice gained over a hundred years of application, are the reason of domination of long-rod porcelain insulators especially in Europe in voltage transmission and distribution systems. The other kind of insulating elements in operation are the glass cap and pin (disc) insulators. They show some drawbacks leading to some limitations of their application. Among disadvantages the most significant

122 P. RANACHOWSKI et al. are: high weight of the insulator sets, no uniform electric field distribution along the string, poor resistance to pollution, partial discharges and gradual ageing processes in the structure and on the glass surface. Nevertheless, the disc insulators are inexpensive and resistant to mechanical rupture. This kind of insulation is dominating on domestic 400 kv extra-high voltage (EHV) overhead lines. The fundamental factor considered when taking a decision, which type of insulator should be preferred, is the quality and operational reliability of the elements of electricity transmission or distribution systems. The consequences of the failure and the maintenance of a high voltage (HV) line considerably exceed the costs of purchasing the insulating elements. Modern projects of HV line should also take into account the problem of climate hazards and air pollution. However, the costs of the energy transmission and distribution influence the total cost of line insulation. The rapid demand for energy supplies dated to early fifties of the XX-th century has led to the growth of projects of ultra-high voltage power systems, even beyond the limit of 1000 kv (in North America). The weight of the insulators, either glass or porcelain, has turned out to be the major problem for the enterprise. That was the cause of growing attention to the synthetic substances, especially epoxy-glass composites. First light insulators with sheds made of epoxide material are dated to 1959 [1]. The progress of the composite insulators construction can be divided into the following periods. The insulators fabricated in 1960 1975 are considered as the first generation. The eighties are the years of introducing the second generation. Wide application of the new technology is related to the third one, appearing in early nineties. Only that generation seemed to be competitive enough in terms of technical and economical aspects. Several different designs of the insulation arrangements (i.e. post and hollow insulators, cross-bar and separating equipment) have been introduced during the last decade, especially in the United States. In this country it is widely understood that application of the composites as the insulating elements results in reduction of both the investing and maintenance costs. EHV lines with composite insulation used solely have been built since 1994 [2]. When compared to the ceramic elements, the composite insulators have significantly smaller diameter and weight. The production method enables easy adaptation of the product dimensions to the particular requirements, eliminating troublesome formation of insulator strings. The new material characterizes the endurable and renewable hydrophobic properties and thus, it is recommended to operate in highly polluted environment. The costs of launching a new product are acceptable and the production itself requires less energy than technology of the ceramics, especially considering the firing process. Due to its elasticity and reduced mass, the composite insulators are also resistant to mechanical shocks and vibrations. Assembly of composite insulators is easy and its maintenance costs are low. It is worth mentioning that in the USA, the overhead line operators suffer from the losses caused by the gunshot attacks on the line insulators. The composite elements are also less sensitive to that kind of hazard. The composite insulators are gradually introduced in Polish medium- and high-voltage networks, especially on 110 kv overhead distribution lines.

ACOUSTIC EXAMINATION OF EPOXY-GLASS INSULATOR MATERIAL 123 2. Construction and degradation hazards of composite insulators The typical line composite insulator consists of three elements, as it is shown in Fig. 1: metal fixing devices situated at both ends; the polymer cover with disc sheds and the glass-epoxy insulating rod. The rod acts as a hard core to endure the mechanical load and voltage gradient. The synthetic rubber cover with sheds ensures the desired leakage path and rain spark-over voltage [3, 4]. Fig. 1. The typical line composite insulator: 1 metal fixing devices situated at both ends, 2 the polymer cover with formed sheds, 3 the glass-epoxy carrying rod [4]. Although the composite insulator can be considered as a relatively simple object, the design and technological problems are still present. The endurance and reliable operation of composite insulator highly depends on firm and tight coupling of its elements. The critical region is the triple junction of the rod, fixing device and the polymer cover. Special attention should be paid to avoid the moisture leak here. When the junction is insufficiently hermetic, the chemical corrosion process could appear at the place of the rod and fixing device connection and it could also result in electrical breakdown what would lead to rod damages. The electrical breakdown effects in the border area of the rod and polymer cover have been definitely eliminated only in the third generation products. The synthetic rubber cover is exposed to such ageing factors like: aggressive gases (ozone and nitride oxides), ultraviolet radiation, temperature changes, moisture, industrial pollution, mechanical stress and voltage gradient. The occurrence of electric fields exceeding the level of 5 7 kv/cm can be a cause of partial discharge effect, which devastates the surface of the rubber cover [5]. To limit these harmful processes, the best synthetic compositions (most frequently silicone rubber) should be applied to form the insulator cover with sheds and perform its proper adhesion to the carrying rod.

124 P. RANACHOWSKI et al. The other process resulting in insulator degradation is the brittle fracture of the carrying rod. It can be caused by different factors: corrosion of the fiberglass (action of nitride acid), inappropriate transportation, improper line support assembly and structure overload occurring during compression of the metal fixing devices. The corrosion effects can be reduced by a proper overall shape design to diminish the electrical field strength level (corona effect reduction), especially close to the core-fixing device junction. The triple point core-fixing device-polymer cover should be protected with a very high accuracy. Also, a very delicate dealing with composite insulators is necessary during its transportation and installation. The control of the pressure acting on the carrying rod of an insulator during the process of setting up the metal fixing devices can be nondestructively performed by the acoustic emission method. 3. Structural and ultrasonic investigation The object of analysis in this work were two types of epoxy-glass rods, produced in Poland. Both the types had the same dimensions but they were prepared using different forming processes. The rods of type A were made using continuous drawing process. The rods of type B were obtained using the analogous method with additional tightening (wrapping round by an elastic fiber). In the case of type A material the density was d A = 1.9 g/cm 3 and contents of roving fibres about 70%. The B composition had higher density d B = 2.1 g/cm 3 and contents of roving fibres over 80%. To make the microscopic inspection, the rods were cut into pieces at different locations and then the surface of the samples was properly prepared. At first the surfaces were ground using SiC powder of 10 µm grain size. Polishing process, using colloidal solution of silica, was performed on a special fabric of 90% porosity. After rinsing in chemically active detergents and drying in alcohol vapors, the microsections were ready for microscopic investigation. The microscopic analysis revealed sufficient homogeneity of both composite materials. No major pore cavities and surrounding crack areas were noticed. These kinds of defects have been found in epoxy-glass insulator composites of older generations Fig. 2. It has been found a little poorer roving filling of the matrix and more areas with no roving contents in samples of type A. The maximal pore diameters were approximately calculated to some scores of micrometers in both compositions. In composition A a small pore amount was detected. In material B the contents of pores was even smaller. The average fiber roving diameter in composition A was 11.2 µm, while in composition B the average fiber roving diameter was 6.3 µm, with remarkable presence of a population of greater fibers analogous to those used in composition A. In both materials were revealed the cracks situated along the fibers. However, these defects occurred more frequently in composition A and only incidentally in material B. The typical microscopic images of both materials are shown in Fig. 3 composition A and in Fig. 4 material B.

ACOUSTIC EXAMINATION OF EPOXY-GLASS INSULATOR MATERIAL 125 Fig. 2. An example of great pore cavity and other inhomogeneities found in epoxy-glass insulator rod of elder generation. Magnification 50. Fig. 3. The typical microscopic image of composition A structure. Faults in roving filling of the matrix and internal cracks of roving fibres are visible. Magnification 200.

126 P. RANACHOWSKI et al. Fig. 4. The typical microscopic image of composition B structure. Sufficient homogeneity and small number of internal cracks of roving fibres are visible. Magnification 200. The ultrasonic measurements were carried out using standard procedures with application of the set-up presented in papers [6, 7]. These works were related to similar problems of ceramic insulators testing. In the case of epoxy-glass composite material, the echo-method and an ultrasonic 4.7 MHz transducer were used. The longitudinal wave propagation velocity and the amplitude attenuation coefficient were measured in two directions parallel and perpendicular to the core axis. Four samples of 40 millimeters length of both the A and B materials were prepared for this investigation. The results of measurement are presented in Table 1. Table 1. The results of ultrasonic longitudinal wave measurements of the composite insulator core rods, performed parallel and perpendicular to the core axis. The following ultrasonic wave parameters were presented as upper and lower limits of four measurements: c L longitudinal mode wave velocity parallel to the core axis, c L longitudinal mode wave velocity perpendicular to the core axis, α c amplitude wave attenuation coefficient parallel to the core axis in central part of the core, α p amplitude wave attenuation coefficient parallel to the core axis in peripheral region of the core, α amplitude wave attenuation coefficient perpendicular to the core axis across the core diameter. Measured parameter Material of type A Material of type B c L [m/s] 4960 5090 5220 5350 c L [m/s] 3230 3360 3490 3600 α c [db/cm] 3.02 4.67 2.89 4.75 α p [db/cm] 1.35 3.87 1.72 3.82 α [db/cm] 6.81 8.46 3.80 5.71 Wave velocity measurements were carried out with accuracy of ±15 m/s and amplitude wave attenuation coefficient measurements were performed with an estimated error of ±0.15 db/cm.

ACOUSTIC EXAMINATION OF EPOXY-GLASS INSULATOR MATERIAL 127 Results of the longitudinal mode wave velocity measurements indicated relatively low dispersion in both investigated compositions. This revealed sufficient material homogeneity. The remarkable difference between c L and c L is a consequence of anisotropy of the roving fiber packing. Cracks appear in considerable part of the fibers, especially in epoxy-glass of type A. There are areas without roving presence, high density of phase borders and low contents of pores. Some fibers are also twisted, what additionally increases the amplitude wave attenuation coefficient. Thus, wave attenuation in the investigated material is characterized by a complex mechanism. The factors listed above result in high variations of the attenuation coefficient, even when it is determined in the same section of the rod. The higher level of attenuation coefficient measured parallel to the core axis in central part of the core in comparison to the peripheral core region can be caused by different pressure level during material formation in those regions. The wave energy absorption in the material is of minor importance when compared to the scattering effects. The structural differences between both compositions are more evident when the average longitudinal wave velocities are compared. In B type material the average wave velocity measured parallel to the core axis c L has the value of 5280 m/s and the average wave velocity measured perpendicular to the core axis c L has the value of 3540 m/s. In A type material the corresponding values are lower: 5040 m/s and 3290 m/s. The values of attenuation coefficient (α c and α p ) are slightly lower in type B epoxy-glass, than in that of type A measurements parallel to the rod axis. In the case of measurements performed perpendicular to the rod axis, the differences in attenuation coefficient are greater. Mean value of α in type B material is equal 4.76 db/cm and mean value of α in type A composite 7.64 db/cm. 4. Acoustic emission investigation Besides microstructural and ultrasonic measurements, the process of compression of the fixing devices on the carrying rod was investigated. This process was performed by a hydraulic press. Compression was realized by automatic multi-element jaw. Direct on-line control of the pressure acting on the carrying rod is difficult. Compressive forces acting on both ends of the rod are analogous. Therefore only one end of the rod was controlled during compression, while to the other end the wideband acoustic emission sensor WD Physical Acoustic Corporation type was coupled. The passband of AE transducer was between 80 and 1000 khz. Transducer was connected with a preamplifier and AE analyzer, coupled with the computer. The applied instrumentation is shown in Fig. 5, presenting the composite medium voltage line insulator with installed fixing devices. In the central part of the picture there is a carrying rod with fixing device placed in the jaws of the hydraulic press. To the other end of the rod the acoustic emission sensor is connected. The preliminary test was performed to estimate the proper compressive force, to obtain a good connection without any damage of the rod material. The suitable compression load was determined in the range 17 21 MPa. The group of three rods of type A and three rods of type B were taken to measure AE effects during fitting of the fixing

128 P. RANACHOWSKI et al. Fig. 5. View of the experimental set-up used to AE control the process of compressing the fixing devices on the medium voltage insulator rod. devices. Experiments were carried out using pressure 17 MPa. The effective values of acoustic emission signals (RMS) generated during compression were registered. The typical time dependence of RMS signal is shown in Fig. 6 (epoxy-glass A) and in Fig. 7 (material B). The whole process can be divided into three stages. During the first stage of the process (4 4.5 s) the compression increased linearly to the value of 17 MPa. During this preliminary stage, a high acoustic activity was generated. Course of the AE activity in this stage was similar for all experiments. This is a consequence of the analogous effect of plastic deformation of metal fixing device. Metal deformation has been recognized as the source of AE signals. In two next stages the compression was maintained at constant level 17 MPa. During the second stage, AE activity remained at low level. The strong acoustic signals were generated in the last stage after eleventh second. They originated from the deformed structure of the epoxy-glass rod. The high RMS value of AE signals can be result of cracking of roving fiberglass in the structure of composite material. Experiments showed a remarkable difference in the course of acoustic energy emission generated by the rods of type A and B. The amplitude of the signal generated by the structure of type A two bursts, was approximately two times greater than that of type B one burst. These results indicate lower mechanical strength and higher number of structural inaccuracies of epoxy-glass material of type A.

ACOUSTIC EXAMINATION OF EPOXY-GLASS INSULATOR MATERIAL 129 130 120 110 100 90 80 70 60 50 40 30 20 10 0 A t [ms] Fig. 6. Time dependence of AE RMS signals, generated in material of type A during fixing device assembly to the insulator rod. 80 70 B 60 50 40 30 20 10 0 Fig. 7. Time dependence of AE RMS signals, generated in material of type B during fixing devices assembly to the insulator rod. 5. Conclusions The paper presents the results of ultrasonic, microscopic and acoustic emission research of carrying rods of medium voltage composite insulators. Investigation was performed for two types of epoxy-glass materials, denoted A and B. The A type composition was fabricated using continuous drawing process. For B composition additional

130 P. RANACHOWSKI et al. tightening method was applied. The measurements revealed higher ultrasonic wave velocities and lower levels of attenuation coefficients measured in B type composition in comparison to material A. These findings are the consequences of differences in microstructure of the materials. There is a higher amount of roving fibers per unit volume and denser structure in B type composition. The concentration of defects was greater in type A material, what considerably influenced the results of the measurements, obtained using both acoustic methods. It seems, that cracks of roving fibres have greater influence on mechanical and acoustic parameters of the epoxy-glass materials, while the pores and roving missing spaces are of less importance. Acoustic emission method confirmed lower mechanical strength of A type epoxy-glass material. This nondestructive technique can be helpful in testing the quality of the rod material and accuracy of the fitting process. References [1] CHERNEY E. A., Important aspects of non-ceramic insulator design, [in:] Symposium on Non- Ceramic Insulator Technology, The North-American Experience, Zurich 1995. [2] Insulator News and Market Report, 2, 4 (1994). [3] MOŚCICKA-GRZESIAK H., Engineering of high tension in electroenergetics, Publishing House of Poznań University of Technology, Poznań 1996. [4] POHL Z., High voltage outdoor insulation in electrical power engineering, Publishing House of Wrocław University of Technology, Wrocław 2003. [5] DE LA O.A., GORUR R.S., Flashover of non-ceramic insulators, IEEE Trans. DEInsul., 5, 6, 814 823 (1998). [6] FLESZYŃSKI J., RANACHOWSKI P., RANACHOWSKI Z., REJMUND F., Non-destructive ultrasonic measurements of ceramic post insulators used in electricity distribution systems, Insight, 45, 7, 493 497 (2003). [7] REJMUND F., RANACHOWSKI P., FLESZYŃSKI J., The ultrasonic method applied to diagnostic operational tests performed on long-rod post insulators, Conference Proceedings 1, Nondestructive Testing of Materials and Structures, AMAS Course NTM 02, 199 214, Warszawa 2002.