RHM60. Coriolis Mass Flow Meter with Uncompromising Performance. Features. Applications. Benefits

Similar documents
RHM80. High Flow Coriolis Mass Flow Meter. Features. Applications. Benefits

RHM 100. Coriolis Mass Flowmeter for High Flow Applications. Applications. Features. Advantages

Coriolis Mass Flowmeter serving thousands of worldwide applications

VersaFlow Coriolis 1000 Mass Flow Sensor Specifications

VersaFlow Coriolis 1000 Mass Flow Sensor Specifications

OPTIMASS 7400 Technical Datasheet

VersaFlow Coriolis 200 Sensor for Mass Flow Specifications

VersaFlow Coriolis 1000 Mass Flow Sensor Specifications

OPTIMASS 7400 Technical Datasheet

Micro Motion TA-Series Flow and Density Meters

Diaphragm seal with flange connection With internal diaphragm Model

Sentinel LNG. Panametrics Ultrasonic Flowmeter for Cryogenic Liquids. GE Sensing & Inspection Technologies. Benefits. Applications

Diaphragm seal with flange connection With internal diaphragm, threaded design Model

Flow Measurement SITRANS F M

Sentinel LNG. Panametrics Ultrasonic Flowmeter for Cryogenic Liquids. GE Sensing & Inspection Technologies. Benefits. Applications

SI-02. Features. Electromagnetic Flowmeter for General Applications. Description: Application:

Rosemount 405 Compact Primary Element

APT3200 SMART PRESSURE TRANSMITTER. Range and Sensor Limits Refer to Table 1. Isolation Input/output isolated to 500Vrms (707 Vdc)

Diaphragm Seal with flush diaphragm and flange acc.to EN or ASME B 16,5 Pressure gauge in stainless steel

TRICOR. TRICOR Series. Technical Datasheet. Mass Flow Meters MISURATORE MASSICO - CORIOLIS MASS FLOW METER CORIOLIS TECHNOLOGY

Diaphragm seal with flange connection Cell-type with extended diaphragm Model

VersaFlow Coriolis 6000 Sensor for Mass Flow Specifications

Differential pressure

VersaFlow Coriolis 200 Sensor for Mass Flow Technical Datasheet. Specification. The solution for bulk mass flow measurement. Features.

ALTOFLUX IFS 4000/4005

TUFFy T3. side Mounting level controls. Worldwide level and flow solutions. compact and cost effective. FeATUres. ApplicATions 2014/68/EU

The perfect fit for tight spaces

VersaFlow Coriolis 1000 Mass Flow Sensor Technical Datasheet. Specification. The superior solution. Highlights. Applications.

Micro Motion H-Series Hygienic Coriolis Flow and Density Meters

Diaphragm seal with threaded connection Threaded design Model

Model 5100 Model 5400 Insertion Turbine Flowmeters for Liquid and Gas

Technical Datasheet. Compact Series Pressure Switch Models: CS2 & CS4. Compact Series. Key Features. Series Overview. Product applications

MICROCOR ER DATALOGGER

Micro Motion LNG Series Meters

Diaphragm seal with flange connection With internal diaphragm, threaded design Model , large working volume

Coriolis Mass Flow Meter

FN04. Liquid level sensor with continuous detection. Level Measurement and Monitoring

VLM10 In-line Vortex Mass Flow Meter

Thermowell with flange (solid-machined) Model TW10-F, full penetration weld design Models TW10-P and TW10-R, with double fillet weld

Roxar Weight Loss Coupon Holder and Coupons 1 Retractable System

XMP i. Precision Pressure Transmitter for the Process Industry with HART -Communication. Stainless Steel Sensor

ISO 9001:2008 certified

I/A Series Coriolis Mass Flow and Density Meters for Standard and 3A Sanitary Applications Models CFS10 and CFS20 Mass Flowtubes

Red Eye Multiphase Water-Cut Meter

SECTION Inline ULTRASONIC FLOW METERS

XMP i. Precision Pressure Transmitter for the Process Industry with HART -Communication. Stainless Steel Sensor

VERIS Accelabar. Superior Flow Measurement Accuracy

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

Tuffy II Liquid Level Controls with Electric Switches

SPRING LOADED THERMOCOUPLE CONFIGURATIONS THERMOWELL & REPLACEABLE INSERT II 2G/D Ex e TCRE/WE

Flowmeters. Positive Displacement meter. Coriolis mass flowmeter. Turbine flowmeter. Ultrasonic flowmeter

LMK 382. Stainless Steel Probe. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.

Large Flange Connections Specification Type LF

TUFFY T3. Side Mounting Level Controls. Worldwide level and flow solutions FEATURES MODELS APPLICATIONS AGENCY APPROVALS

ILMK 382. Stainless Steel Probe. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO.

F-2200 Series Steam Meter

8.27/210 * 7.28/ / / /108. n x d. b f ML00343b. Dimensions are in inches/millimeters *8.86/225 for Pg 13.5 with adapter 2.

Pro-V Multivariable Flowmeter Model M23 Insertion Vortex

Heavy Duty Assembly for the Oil & Gas Industry

CALDON LEFM Ultrasonic Flowmeters for Gas Applications. Integrating experience, proven technology, and innovation

FPD190 Differential pressure restriction orifice plates

Heavy Duty Thermowell for the Oil & Gas Industry. Engineered solutions for optimized and dependable process measurements

VESSEL & REACTOR VALVES. VD Series DISC VALVES PROCESS VALVES

Sentinel LNG. Panametrics Ultrasonic Flowmeter for Cryogenic Liquids. GE Sensing & Inspection Technologies. Benefits. Applications

SERIES OVAL GEAR FLOWMETER MOGF

Coriolis Mass Flow Measurement System promass 63

IOMaster FPD510 Compact integral orifice flowmeter. Low-cost measurement of small flowrates

SPRING LOADED THERMOCOUPLE CONFIGURATIONS

Plastic tube flowmeters Series PT/PS Variable area flowmeter for liquids and gases

Pro-V Multivariable Flowmeter Model M23 Insertion Vortex

THERMOWELL ASSEMBLIES & THERMOWELLS INDEX

EE300Ex-HT. Humidity/Temperature Transmitter for Intrinsically Safe Applications. Typical Applications. Features

METAL & DUAL SEATED PISTON VALVES

Rosemount 1152 Alphaline Nuclear Pressure Transmitter

Datasheet Rev.1 Feb 2016 Orifice plate multi-holes

EE300Ex-HT. Humidity/Temperature Transmitter for Intrinsically Safe Applications. Typical Applications. Features

Thermowell, weld-in or with flange (solid-machined) Version per DIN form 4, 4F Models TW55-6, TW55-7

Target Inline Flowmeter

Pressure transducers DMU 02 Vario (flush)

Tuffy II Liquid Level Controls with Electric Switches

ST3000 Series 900 Smart Transmitter Remote-sealed type of Differential Pressure Transmitters

Thermocouples Straight Design Model TC501, for Flue Gas Measurement

Model 140MX Flowmeter Functional Overview

HLX300Ex-HT. Humidity/Temperature Transmitter for Intrinsically Safe Applications. Typical Applications. Features

DMP 331P. Industrial Pressure Transmitter. Process Connections With Flush Welded Stainless Steel Diaphragm

PRODUCT INFORMATION. Model 140MX Flowmeter Functional Overview. PI 14-1 Rev: 1 March 2002

VESSEL & REACTOR VALVES. VR Series RISING DISC PROCESS VALVES. Sold by: G&W Industrial Sales

Type Type 2000 Transducers. I/P & E/P Transducers

Rev ECN Description Approval Date AA Initial Release RCS 5/21/13

Liquid level switch BW 17

Diaphragm pressure gauge per EN 837-3,

Standard features. Service intended. Design Internal diaphragm. Accuracy Refer to gauge model

Magnetically controlled liquid level indicator. Type: ITA. Technical Catalogue

THE SPECIALIST IN LEVEL AND FLOW

SECTION Coriolis Mass Flow Meters

Process Inline Filter, Change-Over

The Unique Accelabar Flow Meter

Single-Use Sensors. TruFluor and TruTorr Excellence in bio-processing measurement

SECTION CORIOLIS MASS FLOW MEASURING SYSTEM

Transcription:

RHM60 Coriolis Mass Flow Meter with Uncompromising Performance Features Standard pressure ratings up to 490 bar (7107 psi) Temperature ratings from -196 to 350 C (-320 to 662 F) Mass flow uncertainty down to 0.15% Density uncertainty down to 0.5% Repeatability better than 0.05% Typical measuring ranges between 60 and 3000 kg/min Accurately measure low flow rates down to 45 kg/min Unique robust torsion driven oscillation system Process connection customization available Approved for use in hazardous areas Stainless steel case Remote and compact transmitter versions available Applications Typical applications include: Plant Balance Terminal Transfer Asphalt/Bitumen and Other High Temperature Fluids Viscous Fluids Reactor Charging Batching Barge, Ship, Rail Car and Truck Filling Benefits Torsion oscillator design assures a stable and drift free measurement with excellent signal to noise ratios Resilient to external noise and vibration Insensitive to pipe pressure changes Robust tube wall thickness provides increased operational safety in abrasive applications Corrosion resistant Long sensor life guaranteed due to low mechanical stresses in the meter mechanism No moving parts to wear or fail

RHM60 General Specifications Nominal Max Flow Range: 3000 kg/min (6613.9 lb/min) Density Range: 5 to 5000 kg/m 3 (0.31 to 312 lb/ft 3 ) Temperature Range: Pressure Ratings: Electrical Connection: Sensor Housing Materials: Enclosure Type: Material of Wetted Parts: Finishes: Certifications and Approvals: Documentation: Proof Testing: Options: Transmitter Range 5 temperature range options cover temperatures from -196 C to 350 C (-320 F to 662 F) Dependent upon material Cable entry M25 x 1.5 (standard) M20 x 1.5, ½" NPT, ¾" NPT (optional) Max cable length to remote RHE transmitter 30m (98 ft). 100m (330ft) with optional high performance cable 1.4301 / 304 stainless steel (standard), 1.4571 / 316Ti stainless steel (optional) Epoxy coated aluminium electrical box (standard), 1.4571 / 316Ti stainless steel (optional) Protection Class IP 65. Optional IP 66 / NEMA 4X Sensors are available in a variety of standard and custom materials to suit a wide range of pressure ratings and chemical compatibility requirements. See the pressure ratings listing in this document for further details ANSI flange finish: AARH 125 to 250 μin, Ra 3.2 to 6.3 μm ATEX approval Zone 0: Ex II 1 G Ex ia IIC T1-T6 Ga ATEX rating Zone 2: Ex II 3 G Ex na IIC T1-T6 Gc CSA USA-Canada, Class I, Div. 1, Groups A, B, C, D PED according to 97/23/EC Module A1 or Module B + C1 (as required by application) All sensors are supplied with a traceable calibration certificate. Optional documentation items available: - Traceable material certificates - Certificates of origin and conformity - Welding - NACE - Quality - Production and manufacturing procedures Other documentation to client requirements available Hydrotest, dye penetrant, x-ray, PMI Enclosure heating matrix for high temperature applications RHE07 RHE08 RHE11 RHE12 RHE14 RHE16 Any Rheonik Mass Flow Transmitter model can be combined with an RHM60 sensor to provide an overall mass flow measurement system to suit any requirement. Rheonik Coriolis transmitters are designed for process, industrial and OEM applications. Together they offer a tremendous range of options for system designers and end users alike.

RHM60 Measurement Performance Standard Calibration Flow Rate Uncertainty kg/min lb/min in % of reading 3000* 6614 0.20 1000 2205 0.20 300 661 0.20 100 220 0.20 60 132 0.50 Uncertainty % Flow Rate kg/min DP (bar) Goldline Calibration* Flow Rate Uncertainty kg/min lb/min in % of reading 1800 3968 0.15 1000 2205 0.15 500 1102 0.15 300 661 0.15 180 397 0.15 Uncertainty % Flow Rate kg/min DP (bar) Flow Rate Low Flow Calibration* Uncertainty kg/min lb/min in % of reading 2000 4409 0.20 1000 2205 0.20 100 220 0.20 60 132 0.50 45 99 0.60 *Highest calibration point in factory is at 2000 kg/min (4409 lb/min). Stated uncertainty is guaranteed up to 2500 kg/min (5512 lb/min). **Goldline and Low Flow Calibration is not available with all configurations of the RHM60. Please check with factory. Uncertainty % Flow Rate kg/min DP (bar) Mass Flow Calibration Options A 50:1 Standard Calibration 0.5% Uncertainty between 2500 and 60 kg/min B 20:1 Standard Calibration 0.2% Uncertainty between 2500 and 100 kg/min G 10:1 Goldline Calibration 0.15% Uncertainty between 1800 and 180 kg/min 2 Low Flow Calibration 0.2% Uncertainty between 2000 and 100 kg/min, 0.5% between 100 and 60 kg/min, 0.6% between 60 and 45 kg/min Uncertainty of reading (incl. zero drift) stated at reference condition of: H 2 O, 18 24 C (66-76 F), 1-3 bar (15-45 psi) when installed according to field manual Pressure drop indications are based upon H 2 O flowing in a meter with P1 pressure rating For customized calibration range or uncertainty levels, please consult factory Flow Measurement Repeatability Standard ± 0.1% of rate Goldline ± 0.05% of rate Density Measurement Performance (liquids) Standard 2 point calibration ±1% of value Optional 3 point calibration ±0.5% of value Gas density depends upon pressure Temperature Better than ± 1 C

RHM60 Pressure Ratings The maximum pressure (P max ) of a sensor is determined by its lowest rated part. The lowest rated part is either the measuring tube (P max indicated below) or the process connection (for P max see published standards or manufacturer information). RHM60 Measurement Tube Pressure Ratings Pressure Code Material Code Material P1 (std.) P1 M1 (std.) M3 P1 62* P2 M1 (std.) P1 10* P2 62* P3 M3* P2 10* 1.4571 (316Ti) UNS S31635 2.4602 (Alloy C22) UNS N06022 1.4462 (Duplex) UNS S31803 1.4571 (316Ti) UNS S31635 1.4410 (Super Duplex) UNS S32750 1.4462 (Duplex) UNS S31803 2.4602 (Alloy C22) UNS N06022 1.4410 (Super Duplex) UNS S32750 p max bar psi C F 104 1508 @ 50 122 93 1349 @ 120 248 80 1160 @ 210 410 67 972 @ 350 662 138 2002 @ 50 122 122 1769 @ 120 248 104 1508 @ 210 410 86 1247 @ 350 662 188 2727 @ 50 122 165 2393 @ 120 248 144 2089 @ 210 410 206 2988 @ 50 122 184 2669 @ 120 248 159 2306 @ 210 410 134 1944 @ 350 662 236 3423 @ 50 122 207 3002 @ 120 248 187 2712 @ 210 410 270 3916 @ 50 122 237 3437 @ 120 248 207 3002 @ 210 410 283 4105 @ 50 122 250 3626 @ 120 248 214 3104 @ 210 410 178 2582 @ 350 662 490 7107 @ 50 122 430 6237 @ 120 248 389 5642 @ 210 410 *Only with T1, TA, T2 temperature range (note min. temp. is -40 C) Other Materials Additional/custom wetted materials (Inconel, Monel, 304 stainless steel, others) may be possible for chemical compatibility, lower pressure drop, abrasion allowance, other application specific requirements. Contact factory with specification for assessment and availability.

RHM60 Mechanical Construction PF0: Seal-less parallel measuring tube construction with flange connections Process Connection Face to face length (L) Order Code mm in ANSI 4" 150# RF 725 28.54 F1 ANSI 4" 300# RF 725 28.54 F2 ANSI 4" 600# RF* 725 28.54 F3 ANSI 6" 1500# RF 900 35.43 AA ANSI 4" 900# RTJ 900 35.43 R0 ANSI 4" 1500 RTJ 900 35.43 R2 ANSI 4" 2500 RTJ 900 35.43 R3 ANSI 6" 300# RTJ 900 35.43 R5 DIN DN100/PN16 725 28.54 D4 DIN DN100/PN40 725 28.54 C1 DIN DN100/PN100* 725 28.54 C2 For customization of face to face length and/or special fittings other than the ones listed on this page, please consult factory. Note that larger diameter flange process connections are always possible. A1 = 910 mm (35.83 in) A2 = 950 mm (37.40 in) B1 = 150 mm (5.91 in) B2 = 230 mm (9.06 in) HI = 1253 mm (49.33 in) H2 = 1443 mm (56.81 in) E = 300 mm (11.81 in) W = 150 mm (5.91 in) Electrical box: std. = 125 x 80 x 58 mm (4.92 x 3.15 x 2.28 in), RHE16 compact = 120 x 120 x 80 mm (4.72 x 4.72 x 3.15 in) *This flange selection will reduce maximum allowable measurement tube pressure rating by a factor of 0.73. Weights and Shipping Dimensions Typical weight with 4" 150# flanges: approx. 235 kg (518 lb) RHM60 meters ship in a wooden crate (to ISPM 15). Typical dimensions approx. 180 x 120 x 75 cm (71 x 48 x 30 in) Typical gross shipping weight example: RHM60 with 4" 150# flanges c/w RHE08 transmitter approx. 310 kg (683 lb)

RHM60 Part Number Code Temperature Range T1-20 C to +120 C (-4 to +248 F) (std.) TA -45 C to +120 C (-49 to +248 F) T2-45 C to +210 C (-49 to +410 F) T3-196 C to +50 C (-320 to +122 F) T4 0 C to +350 C (+32 to +662 F) P max of Measuring Loops (see pressure rating page) P1 P max depends upon material P2 P max depends upon material Material of Wetted Parts M1 1.4571 (316Ti) M3 2.4602 (Alloy C22) 62 1.4462 (Duplex) 10 1.4410 (Super Duplex) Process Connection See mechanical construction page for available connections and codes Options Codes See options listing for specific codes Terminal Box Selection 9 Remote transmitter cable termination box (std.) C Enclosure for compact mount RHE16 transmitter Hazardous Area Certifications N Without Ex approval A ATEX approval Zone 0: Ex II 1 G Ex ia IIC T1-T6 Ga 2 ATEX rating Zone 2: Ex II 3 G Ex na IIC T1-T6 Gc C CSA approvals USA-Canada Class I, Div. 1, Gr,. A, B, C, D Pressure Design Compliance NN No design compliance selected A1 PED to module A1 [Europe] BC PED to module B+C1 [Europe] CA CRN (Alberta Province) [Canada] CR CRN (All other Provinces) [Canada] Mass Flow Calibration Selection See performance page for code options Density Calibration Selection D 1% Accuracy (std.) S 0.5% Accuracy RHM60 PF0 N Options H1 Hot oil/steam heating matrix for housing, DN25 PN40 SH Housing in 316Ti stainless steel H2 Hot oil/steam heating matrix for housing, 1" ANSI 150 RF DY Dye penetrant inspection H3 Hot oil/steam heating matrix for housing, 1" ANSI 300 RF XR X-ray test P2 Housing purge for dry gas ½" NPT (2 pcs) O Oil/grease free cleaning