CONTENTS. B. System Design and Performance Requirements

Similar documents
Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: Electrical Standards

SECTION GROUNDING AND BONDING

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

SECTION GROUNDING

SECTION GROUNDING AND BONDING FOR ELECTRICAL SYSTEMS

SECTION GROUNDING AND BONDING

SECTION PART 1 GENERAL

A. All materials shall be tested and listed by an OSHA approved Nationally Recognized Testing Laboratory (NRTL).

SECTION GROUNDING AND BONDING FOR ELECTRONIC SAFETY AND SECURITY

SECTION GROUNDING AND BONDING

2003 International Residential Code ELECTRICAL PROVISIONS ONLY October 2005 EDITORIAL CHANGES SEVENTH PRINTING

A. Provide a complete Distribution Panelboard system as indicated on the drawings, and as specified herein.

SECTION GROUNDING AND BONDING

DIVISION 16. Electrical Specifications

This product specification is written according to the Construction Specifications Institute MasterFormat, 2014 Update.

This product specification is written according to the Construction Specifications Institute MasterFormat, 2014 Update.

Kaf-Tech Product Specification

NORTHEASTERN REMC ELECTRIC STANDARDS MANUAL

UNDERGROUND SERVICES SECONDARY

SECTION WIRE AND CABLE Raceways and Conduit Motor Power and Control Wiring.

WIRE AND CABLE Raceways and Conduit Motor Power and Control Wiring.

SECTION OUTLET, PULL, AND JUNCTION BOXES

Essex County College - West Essex Campus Addition And Renovations dlb # / 11-14

SECTION SECONDARY UNIT SUBSTATIONS

1. Telecommunications mounting elements. 2. Backboards. 3. Telecommunications equipment racks and cabinets. 4. Grounding.

Standard of Practice - Campus Electrical Distribution System

CHAPTER 13 GROUNDING AND BONDING

3. Intermediate metal conduit (IMC). 4. Electric metallic tubing (EMT). 5. Flexible metal conduit (FLEX). 6. Polyvinyl chloride conduit (PVC).

NORTHWESTERN UNIVERSITY PROJECT NAME JOB #

A. Basket Cable Tray: A fabricated structure consisting of wire mesh bottom and side rails.

BASIC ELECTRICAL MATERIALS AND METHODS

SECTION FACILITY LIGHTNING PROTECTION

B. Provide a complete conduit system with associated couplings, connectors, and fittings.

SERVICES CHAPTER 35. wire. For all other installations, the rating of the ungrounded conductors shall be not less than 60 amperes.

2008 NEC Guide Lines for Home Owner Doing Electrical Work on their Property

1. Hangers and supports for electrical equipment and systems.

OVERHEAD SERVICES - SECONDARY

ELECTRICAL SECTION 2

OPERATING PROCEDURE NO. 310

DIVISION 26 RACEWAYS AND BOXES FOR ELECTRICAL SYSTEMS PART 1 - GENERAL RELATED DOCUMENTS

GLENWOOD PLACE 2 MAR 2015

Click here to get back to 2011 NEC Code Updates Part 1

DESIGN GUIDELINES WIRING AND CONDUITS PAGE 1 of 7

Telecommunication Spaces

SERVICE ENTRANCES. OPPD S Electrical Service Designer (ESD) shall designate the Point Of Entrance.

1. Hangers and supports for electrical equipment and systems. 2. Construction requirements for concrete bases.

a) Line and load compartments must be separated by a stable barrier.

SECTION GROUNDING AND BONDING FOR ELECTRICAL SYSTEMS

SECTION (Master Template Final-05) ELECTRICAL BOXES. A. Provide boxes for electrical equipment and wiring devices as follows:

METERING INSTALLATION

Table of Contents. Preface

6. SECONDARY SERVICES (under 600 volts) 6.1 AVAILABILITY For the electrical characteristics of available secondary services see Section 3.4.

ELECTRICAL SAFETY Information Bulletin

A. Product Data: For surface pathways, wireways and fittings, floor boxes, hinged-cover enclosures, and cabinets.

ELECTRICAL SAFETY Information Bulletin

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 5/12/10 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions

2. Fittings shall be threaded and finished similar to conduit. Threadless fittings shall not be used.

NYULMC AMBULATORY CARE CENTER FIT-OUT PHASE 1 Perkins & Will Architects PC 222 E 41st ST, NYC Project: Issued for GMP March 15, 2017

8. REVENUE METERING. Operational Excellence Model. 8.1 Introduction

SECTION EARTHING AND EARTH FAULT PROTECTION

UNDERGROUND SERVICES (RESIDENTIAL) SINGLE FAMILY RESIDENTIAL, DUPLEXES, OR TOWNHOUSES

UNDERGROUND SERVICES - GENERAL SERVICE AND MULTI-UNIT RESIDENTIAL

ZG Scope. 2 Applicable Documents. 3 General. 4 Stock Item Numbers. Padvault Single-Phase Residential, 2.1 PacifiCorp Material Specifications

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: Electrical Standards

16300 HIGH VOLTAGE DISTRIBUTION

CONSTRUCTION SPECIFICATION FOR GROUNDING

Section 70 Airport Transformer Vault and Vault Equipment (FAA L-109)

A. Basket Cable Tray: A fabricated structure consisting of wire mesh bottom and side rails.

OVERHEAD SERVICES - RESIDENTIAL & GENERAL SERVICE. See Chapter 3, Section 3.01 for more information about point of entrance (POE).

NORTHEASTERN REMC ELECTRIC STANDARDS MANUAL

SECTION LOW-VOLTAGE ELECTRICAL POWER CONDUCTORS AND CABLES (24 Volt AC/DC or Less)

6. SECONDARY SERVICES (under 600 volts) 6.1 AVAILABILITY For the electrical characteristics of available secondary services see Section 3.4.

(Condensed from National Electric Code)

SECTION LIGHTNING PROTECTION SYSTEM

8.1.2 Under no circumstances shall a service entrance be left unmetered. Notify the Company if an unmetered service is encountered.

ELECTRICAL CONTRACTORS THE UNIVERSITY OF TENNESSEE KNOXVILLE, TENNESSEE SECTION PAGE 1 SECTION SUPPORTING DEVICES

Basic Requirements for Residential Electrical Installations

EFFECTIVE DATE: November 1, 2011, unless a later date is cited at the end of a section. [ NMAC - Rp,

Raceway and Boxes for Electrical Systems Page 1 of 7

ITEM L-119 AIRPORT OBSTRUCTION LIGHTS DESCRIPTION

SECTION ENCLOSED BUS ASSEMBLIES

DOWNTOWN UNDERGROUND NETWORK SECONDARY SERVICES GUIDELINES

SECTION BASIC ELECTRICAL REQUIREMENTS

Electric Service Standards

SECTION (16071) - VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

SECTION WIRE, CABLE AND BUSWAYS. A. This section specifies providing wire, cable and busways.

The Medical Center Company Electrical System Installation Requirements

GENERAL NOTES PEDERNALES ELECTRIC COOPERATIVE, INC. RESIDENTIAL AND COMMERCIAL AMP METER LOOP SPECIFICATIONS

Section 7: Specifications

Inspection Guide for PV Systems in One- and Two- Family Dwellings (For Rooftop Photovoltaic Systems meeting the Standard Plan)

Appendix C - International NEC Electric Code Amendments

NEC 2014 Code Changes

DEVICES AND LUMINAIRES

SECTION CONDUITS AND BACKBOXES FOR COMMUNICATIONS SYSTEMS

Sections through of Chapter 5 of the Victoria City Code are amended to read as follows: ARTICLE IX. NATIONAL ELECTRICAL CODE

CITY OF OCEANSIDE. Electrical Lines, Plumbing and Mechanical Burial & Support Requirements. Informational Bulletin

Replace 210.8(a)(7) with: Sinks. Where receptacles are installed within 6 feet of the outside edge of a sink. Page 1 of 5

SECTION VIBRATION CONTROLS FOR PLUMBING PIPING AND EQUIPMENT

The General Provisions of the Contract, including General, Supplementary and Special Conditions, apply to the work specified in this Section.

Transcription:

16060 Grounding and Bonding This document provides design standards only, and is not intended for use, in whole or in part, as a specification. Do not copy this information verbatim in specifications or in notes on drawings. Refer questions and comments regarding the content and use of this document to the Yale University Project Manager. CONTENTS A. Summary B. System Design and Performance Requirements C. Product Standards D. Manufacturers E. Materials F. Preparation G. Installation Guidelines H. Quality Control A. Summary This section contains design criteria for the grounding of building services and separately-derived systems under 600 volts. Building service can refer to utility services or services originating in other Yale University buildings. This section also contains design criteria for grounding and bonding electrical equipment. B. System Design and Performance Requirements 1. Ground all equipment with insulated ground wires run in conduit with circuit conductors. Construct metal raceway systems to create an independent and redundant ground path bonded to the ground wire at all boxes and enclosures. Provide another redundant ground where nonmetallic conduits are used (for example, ground rods at site lighting fixtures). 2. For all circuits of systems over 50 volts to ground, include an insulated equipment grounding wire sized according to NEC requirements. In addition, design metal raceway systems to serve as a redundant grounding conductor, and bond the insulated grounding wire to the metal raceway system at all terminations. 3. Where isolated grounding systems are provided, provide an additional insulated grounding wire to serve isolated ground terminals. Isolated ground wire conductor shall be green with yellow tracer. 4. Provide all building services with a minimum of two grounding electrodes described by the NEC and bonded together to form a grounding electrode system. Subdivision 16000: Basic Electrical Materials and Methods 1

Section 16060: Grounding and Bonding 5. Ensure that all grounding electrode system bonding conductors are the same size and type as the grounding electrode conductor from the system neutral connection and are run within a separate and independent conduit system. a. Make connections to metal underground water piping within five feet of the point at which the pipe enters the building. Also, all water meters in piping shall have ground conductor jumper across the meter. b. Effectively ground metal building frames by using connections to concreteencased electrodes within the foundation, a ground ring encircling the building, or driven ground rods, but no less than six feet apart. c. Provide concrete-encased electrodes and ground rings for all new buildings. d. Where ground rods are provided, install a minimum of three ¾ by 10 feet long copper clad ground rods, and bond them together to form a grounding electrode. The three grounding electrodes shall be spaced in a triad arrangement six feet apart or at a minimum distance equal to the depth of the rods. 6. Do not bond neutral conductors to grounding conductors at locations other than those specifically allowed by the NEC. Connect generators to wiring systems by transfer switches employing solid neutrals. Do not bond grounding conductors to neutral conductors at generators. 7. Where a special grounding system (for example, an isolated ground or ground grid) is provided for sensitive electronic equipment, bond the grounding system to the equipment grounding conductor only at the grounding system's point of connection to the system neutral conductor. Special grounding systems that are completely isolated from the building's normal equipment grounding system are never acceptable. Where shielded isolation transformers are provided, bond the electrostatic shield to the primary circuit equipment grounding conductor. 8. On construction drawings, indicate all required methods of service grounding and eparately derived system grounding by specific details or notes. References to NEC requirements without such details or notes is not acceptable. 9. All new building modifications shall provide and install a building ground loop which will contain ground rods at100 apart. This ground loop shall be connected to electrical service ground and main water pipe. Grounding cable shall be independent of all other conduit systems. Subdivision 16000: Basic Electrical Materials and Methods 2

Section 16060: Grounding and Bonding 10. Ensure that all building main service transformers are wired to the main electrical room individually. Wire the ground bus to the water main. The size of the conductor is determined by the NEC 250.30 and NEC 250.104. Duplex switchgears, double-ended substations, 300 kva or larger transformers, motor control centers, and other major electrical equipment shall be grounded in two locations on that equipment with 4/0 size of conductor tying to the building ground. Major pieces of mechanical equipment such as chillers, air compressors, mechanical skid package frames have to be grounded with 4/0 conductor to building ground. C. Product Standards Ensure that all products conform to the requirements contained in UL 467, Electrical Grounding and Bonding Equipment. D. Manufacturers Any products that meet the materials requirements are acceptable. E. Materials 1. Use copper-clad steel ground rods with a minimum diameter of 3/4 inches and a minimum length of 10 feet. Where longer rods are required, use 1-inch diameter sectional rods. 2. For grounding conductors, use green insulated building wire, as described in Section 16120: Conductors and Cables. 3. Connectors used for grounding must meet the following requirements: a. Mechanical connectors shall be cast bronze. Connectors used in branch circuits with #14 to #10 AWG solid conductors may be spring wire connectors with a green plastic shell, designed for grounding. b. Compression connectors must be copper. c. Welded connections must be exothermic-type and copper. Subdivision 16000: Basic Electrical Materials and Methods 3

Section 16060: Grounding and Bonding F. Preparation 1. Where new feeders terminate in existing switchboards that do not contain grounding busses, specify new copper grounding busses sized at 20 percent of the phase busses, located at the bottom of the enclosures, and extending the full width of the enclosures. 2. Where new circuits terminate in existing panelboards and the ground bar is full or does not exist, specify a new ground bar. Subdivision 16000: Basic Electrical Materials and Methods 4

Section 16060: Grounding and Bonding G. Installation Guidelines 1. Where ground grids are required under raised floors, specify #2 AWG bare copper conductors in each direction on 24-inch centers with cross-type compression connectors where grid conductors cross. Bond each item of equipment in room individually to the grid and to the isolated grounding conductor. Bond the grid directly to the isolated grounding conductor. Where necessary, bond the grid to each floor pedestal. 2. For buildings with metal siding that does not have an electrical connection to a metal building structure, bond the siding to equipment grounding conductors in panelboards at a minimum two, diametrically opposite locations. 3. Provide ground busses in all access holes and vaults containing circuits operating over 600 volts. 4. Specify new insulated or isolated ground bar for all panelboards through which isolated grounding conductors are run. 5. Do not bond isolated grounding conductors to equipment grounding conductors at locations other than at the point where system neutral is bonded to grounding electrodes. In small projects where new wiring does not extend beyond a local panelboard, insulated or isolated ground bar may be bonded to equipment ground bar in the panelboard. 6. At isolated grounding receptacles, bond the equipment grounding conductor to the box. 7. A ground ring encircling a building shall be buried at a depth of not less than 30 below the earth s surface. H. Quality Control Test the resistance to ground of all grounding electrodes under any of the following conditions, and submit the test results to Yale University. Where new low voltage building services are installed. Where existing low voltage building services are upgraded. Where new or replacement grounding electrodes are installed or newly connected. Subdivision 16000: Basic Electrical Materials and Methods 5

Section 16060: Grounding and Bonding End of Section Subdivision 16000: Basic Electrical Materials and Methods 6

16072 Electrical Supports and Seismic Restraints This document provides design standards only, and is not intended for use, in whole or in part, as a specification. Do not copy this information verbatim in specifications or in notes on drawings. Refer questions and comments regarding the content and use of this document to the Yale University Project Manager. CONTENTS A. Summary B. System Design and Performance Requirements C. Manufacturers D. Materials E. Installation Guidelines A. Summary This section contains design criteria for supporting devices, including anchors and fasteners for raceways and equipment. B. System Design and Performance Requirements 1. When located in the following facilities, design the electrical system components listed in paragraph 2 to withstand the effects of seismic forces. Comply with the requirements of the Connecticut State Building Code. Buildings occupied by University police Power plants Telecommunications equipment centers Buildings containing hazardous materials in excess of exempt amounts allowed by code Health care facilities Assembly occupancies Residential colleges, dormitories, and similar buildings that house students Laboratories and classroom buildings exceeding 50,000 square feet gross area Subdivision 16000: Basic Electrical Materials and Methods 7

Section 16072: Electrical Supports and Seismic Restraints 2. When located in the occupancies listed in paragraph 1, design supports for the following types of equipment to withstand the effects of seismic forces. Conduits supported by individual hangers more than 12 inches in length from the top of the conduit to the bottom of the supporting structure Conduits 2-1/2 inches trade size and larger Transformers Switchgear and switchboards Bus ducts Panelboards Motor control centers Motor controllers Motors Lighting fixtures * If over 12, then flexible fitting is required for raceway. 3. Design supports for the following types of equipment, including associated raceways, to withstand the effects of seismic forces in all buildings, regardless of occupancy. All components of systems operating over 600 volts, including manholes and duct banks. Substations. Emergency electrical systems, legally required standby systems, and optional standby systems, including all wiring on line sides of transfer switches. Fire alarm systems. Telecommunications systems from plant to telephone cabinets and backboards. 4. Design all raceway and equipment supports for easy installation and removal or disassembly with as little damage as possible to the underlying structure. System shall use fastening systems, such as screws, bolts, and beam clamps, unless specific design conditions require alternate supporting methods. Nails, power-driven studs, welds, and similar methods are not acceptable. C. Manufacturers Any product that meets the materials requirements is acceptable. Subdivision 16000: Basic Electrical Materials and Methods 8

Section 16072: Electrical Supports and Seismic Restraints D. Materials 1. Use galvanized steel, aluminum or malleable iron supports, treated for rust resistance. Any cuts for support shall be treated with a rust inhibitor. 2. Use stainless steel fasteners in damp and wet locations and where they are exposed to view in finished areas. 3. Use expansion shield or expansion bolt anchors in concrete or masonry structures that are rated to support, at a minimum, four times the anticipated load. Anchors attached to concrete ceilings must be vibration- and shock-resistant. 4. Use 3/4-inch thick exterior grade plywood backboards, primed and painted prior to mounting. E. Installation Guidelines 1. Use beam clamps when mounting to structural steel construction. Do not drill structural steel. 2. For surface-mounted panelboards and equipment cabinets installed against walls, provide support channels to create a minimum one-inch ventilation air space behind the enclosure. End of Section Subdivision 16000: Basic Electrical Materials and Methods 9

16075 Electrical Identification This document provides design standards only, and is not intended for use, in whole or in part, as a specification. Do not copy this information verbatim in specifications or in notes on drawings. Refer questions and comments regarding the content and use of this document to the Yale University Project Manager. CONTENTS A. Summary B. System Design and Performance Requirements C. Manufacturers D. Materials E. Installation Guidelines A. Summary This section contains design criteria for electrical and wiring identification systems. B. System Design and Performance Requirements 1. Ensure that identification systems are compatible with existing systems, provide for future additions to system, and are consistent throughout the project. 2. On construction documents, indicate identification systems and designations for all equipment and wiring. 3. On identifying plates, indicate unit designation or load served, as applicable, and other information not readily apparent, which might be required by service personnel, particularly with regard to emergency conditions. 4. Ensure that color-coding for power and lighting circuits is in accordance with Section 16120: Conductors and Cables. 5. For systems such as fire alarm, intrusion detection, access control, intercom, public address, television, and audio/visual, ensure that the color-coding of wiring is in accordance with Yale University and industry or manufacturers' standards. In instances where these standards conflict, Yale University standards take precedence. 6. In accordance with Section 16442: Panelboards, follow a specific methodology for panelboard designations. Show the designation on every panel schedule on the panel door and in the construction document. Subdivision 16000: Basic Electrical Materials and Methods 10

Section 16075: Electrical Identification C. Manufacturers Any product that meets the materials requirements is acceptable. D. Materials 1. For equipment identification plates, use: Laminated phenolic resin Black with a white core (unless specific design conditions require an alternate color scheme) Engraved lettering Plates shall be screwed on with stainless steel screws. Adhesive tape is not acceptable. 2. For branch circuit wiring and circuit cable identification markers for systems such as fire alarm and intrusion detection, use: Pre-printed plastic Black-on-white background Pressure-sensitive adhesive 3. For identification markers for such components as feeders, switchboard buses, and transformer terminals, use: Pre-printed vinyl cloth Black-on-yellow background One-inch lettering (minimum) Pressure-sensitive adhesive 4. For all cables in manholes and feeding main services into buildings, all phase conductors shall be tagged with the feeder identification. The tags shall be as follows: 1-1/2 Tech Products tags Black lettering with yellow background Identify all phase conductors in manholes and sub feeders to buildings 5. Control panels for sump pumps and other control systems use: Vinyl sleeves with typed indelible ink for all control wires Subdivision 16000: Basic Electrical Materials and Methods 11

Section 16075: Electrical Identification All devices in panel to have identification plates for components using laminated phenolic resin nameplates (see #1 above) 6. Building Automation Systems shall have identification in panel for the followings: All controller numbers, I/O tag, address All control and signal cable contain the controller number I/O tag number including the address The control and signal cables shall be tagged at both ends pe r Section 15900 HVAC Instrumentation and Controls E. Installation Guidelines 1. Provide all equipment, including switchboards, panelboards, transformers, safety switches, and motor controllers with identification plates secured with stainless steel screws. 2. Neatly type directories for equipment controlling multiple circuits (panelboards, fire alarm control panels, intrusion detection control panels), and mount them on the inside of the panel front cover. Ensure that circuit numbers marked in the field match the circuit numbering contained in the construction documents, so that future references to system wiring can be obtained easily. 3. Identify branch circuit numbering at the panelboard. Identify wiring for other systems, such as fire alarm and intrusion detection, at all terminations and connections. 4. When required by individual standards, such as fire alarm systems and energy management and control systems standards, paint conduit and boxes to identify the system contained within. Painting is described in Division 9, Finishes standards. End of Section Subdivision 16000: Basic Electrical Materials and Methods 12