Song Pan et al. / Energy Procedia 142 (2017)

Similar documents
Available online at ScienceDirect. Procedia Engineering 121 (2015 )

Effect of insulation ground on anti-condensation in rural residence

Available online at ScienceDirect. Procedia Engineering 121 (2015 )

Available online at ScienceDirect. Procedia Engineering 121 (2015 )

Fresh air pre-cooling and energy recovery by using indirect evaporative cooling in hot and humid region a case study in Hong Kong

Comparative Heating Performances of Ground Source and Air Source Heat. Pump Systems for Residential Buildings in Shanghai

Simulation Studies on Performance of Solar Cooling System in UAE Conditions

Numerical and analytical analysis of groundwater influence on the pile ground heat exchanger with cast-in spiral coils

Available online at ScienceDirect. Energy Procedia 78 (2015 )

Application of solar cooling system in a campus library in Hainan, China

Optimizing the Configuration of a Compact Thermal Facade Module for Solar Renovation Concept in Buildings

Experimental Performance Analyses of a Heat Recovery System for Mechanical Ventilation in Buildings

Heat Pump Technology Applies on Air-conditioners Impact on Electric Power

Case Study of Smart Meter and In-home Display for Residential Behavior Change in Shanghai, China

Available online at ScienceDirect. Procedia Engineering 121 (2015 )

A Combined Thermal System with an Air-cooled Organic Rankine Cycle (ORC)

Modeling and simulation of a reclaimed water source heat pump system based on TRANSYS 1

Technical and Economic Analysis on the Large-scale Application of Renewable Energy in Buildings

The performance of a heat pump using nanofluid (R22+TiO 2 ) as the working fluid an experimental study

Available online at ScienceDirect. Procedia Engineering 121 (2015 )

Available online at ScienceDirect. Procedia Engineering 121 (2015 )

Simulation of Solar Air-Conditioning System with Salinity Gradient Solar Pond

LIFE CYCLE ASSESSMENT FOR COOLING AND HEATING SOURCES OF BUILDING

Design, Fabrication and Experimental Study of a Novel Loopheat-pipe based Solar Thermal Facade Water Heating System

Study on train headway in different turning-back mode of urban mass transit station

Application of Low Cost Active and Passive Energy Saving Technologies in an Ultra-low Energy Consumption Building

*Corresponding authors. Tel.: x415, address: (N. Zhu)

Experimental Investigation on Heat Pump for Electric Vehicles with different refrigerant injection compressors

Research on integrated solar and geothermal energy engineering design in hot summer and cold winter area

FIELD TEST STUDY ON THE PERFORMANCE OF AIR SOURCE HEAT PUMP IN LOW TEMPERATURE IN BEIJING

Study of Performance Improvement of Air Conditioning using Various Heat Recovery Techniques

A review on heat transfer enhancement of borehole heat exchanger

Available online at ScienceDirect. Energy Procedia 70 (2015 )

Cooling and recovery of heat from underground railway tunnels for district heating

Available online at ScienceDirect. Procedia Engineering 121 (2015 )

Borehole storage coupled with heat pump for domestic heating system and space free cooling

Available online at ScienceDirect. Energy Procedia 81 (2015 )

Procedia - Social and Behavioral Sciences 138 ( 2014 ) Discussions on the Local Rail Transit System in the Urbanization

Strategic outlook of Heat pump development in China

Available online at ScienceDirect. Procedia Engineering 121 (2015 )

THERMAL ENVIRONMENT OF OUTDOOR UNITS OF VRV SYSTEM IN HIGH- RISE BUILDING. Gang Wang, Yafeng Hu, and Songtao Hu

Available online at ScienceDirect. Procedia Engineering 113 (2015 )

Available online at ScienceDirect. Procedia Engineering 121 (2015 )

Central Chiller Plants

Impacts of emission reduction target and external costs on provincial natural gas distribution in China

Available online at ScienceDirect. Procedia Engineering 121 (2015 )

State of the Art of Air-source Heat Pump for Cold Regions

ANALYSIS OF LIFE CYCLE ENERGY CONSUMPTION AND ENVIRONMENTAL LOAD OF INSULATION DESIGN FOR RESIDENTIAL BUILDINGS IN CHINA

Available online at ScienceDirect. Procedia Engineering 146 (2016 )

Improvement of the Performance for an Absorption Refrigerating System with. Lithium bromide-water as Refrigerant by Increasing Absorption Pressure 1

Experimental Research and Performance Analysis of a Solar-Powered. Air-conditioning System in a Green Building

Heat exchanger performance of ground source heat pump by water cooling method

A survey on energy consumption status and characteristics of hotel buildings in Guangzhou

Available online at ScienceDirect. Energy Procedia 70 (2015 )

Procedia - Social and Behavioral Sciences 138 ( 2014 )

Article Simulation Analysis of Solution Transportation Absorption Chiller with the Capacity from 25 RT to 1000 RT

Chapter Six{ TC "Chapter Six" \l 1 } System Simulation

ScienceDirect. Experimental study of a single quartz tube solid particle air receiver

Available online at ScienceDirect. Energy Procedia 78 (2015 )

Research on the Building Water Supply and Drainage System Energy Saving Methodology based on Structure Optimization.

Simulation Analysis of Mass Concrete Temperature Field

Study on the change of soil temperature in Ground Source Heat Pump System Shili Han1, a*, Shunyu Su1,b, Lamei Liu1,c, Chuanhui Zhou1,d, Lei Shi2,e

Available online at ScienceDirect

Study on the heat transfer model and the application of the underground pipe system

Study on Water-Cooled Solar Semiconductor Air Conditioner

Available online at ScienceDirect. Energy Procedia 91 (2016 )

Energy savings in commercial refrigeration. Low pressure control

COPs, EERs, and SEERs

Available online at ScienceDirect. Energy Procedia 91 (2016 )

SOLAR COOLING WITH SMALL SIZE CHILLER: STATE OF THE ART

HEATING SYSTEM RETURN TEMPERATURE EFFECT ON HEAT PUMP PERFORMANCE

Investigation on effects of piping on heating performance of multi-split variable refrigerant flow system

ENERGY AND EXERGY ANALYSIS OF HEAT PUMP USING R744/R32 REFRIGERANT MIXTURE

System Dynamics Model of Shanghai Passenger Transportation Structure Evolution

Verification of Chiller Performance Promotion and Energy Saving

OPTIMIZATION OF PCM NUMBER IN HOT WATER TANK FOR THE APPLICATION OF SOLAR DRIVEN ADSORPTION CHILLER IN TROPICAL CLIMATE

Available online at ScienceDirect. Energy Procedia 61 (2014 )

Available online at ScienceDirect. Energy Procedia 78 (2015 )

Available online at ScienceDirect. Energy Procedia 105 (2017 )

ScienceDirect. Compact hot water storage systems combining copper tube with high conductivity graphite and phase change materials

AN LCA FRAMEWORK FOR BUILDINGS IN CHINA

System cost and efficiency optimization by heat exchanger performance simulations

Recovery of Waste Heat in Diesel Engine Coolant for Air Conditioning

LCCP Analysis of Energy-Saving Effect of Defaulting to Recirculated Cabin Air in EV Mobile Air Conditioning System

A novel CO 2 -capturing natural gas combined cycle with LNG cold energy utilization

Experimental investigation on a ceiling capillary radiant heating system

LARGE-SCALE APPLICATION OF MUNICIPAL RECLAIMED WATER SOURCE HEAT PUMPS TO A DHC SYSTEM IN THE BEIJING OLYMPIC VILLAGE

Thermally operated mobile air-conditioning system

Available online at ScienceDirect. Energy Procedia 75 (2015 )

Advanced energy saving in the evaporation system of ammonium sulfate solution with self-heat recuperation technology

ScienceDirect. Thermal performance of a quartz tube solid particle air receiver

Design and development of a residential gas-fired heat pump

Measurement and verification of load shifting interventions for a fridge plant system in South Africa

Research Article Investment and Economy Analysis of Water-Source Heat Pump System in Chongqing, China

Available online at ScienceDirect. Procedia Engineering 105 (2015 )

Simulation Study on Geothermal Direct Supply Combined with Water Source Heat Pump Qing HAO 1, a, Meng SI 2, b

Influencing Factors on Ground Heat Balance of GSHP System Xiaohong Zhang1, a *, Zehua Liu2,b, Chao Zhang3,c and Long Ma4,d

Energy consumption simulation of the prototypical building for optimizing the orientation of building model in the simulated environment

Application of Steam Turbine Driven Chillers in CHP/DES System

Available online at ScienceDirect. Physics Procedia 67 (2015 )

Transcription:

Available online at www.sciencedirect.com ScienceDirect Energy Procedia 142 (2017) 2568 2573 www.elsevier.com/locate/procedia 9th International Conference on Applied Energy, ICAE2017, 21-24 August 2017, Cardiff, UK An Investigation on Energy Consumption of Air Conditioning System in Beijing Subway Stations Song Pan a, *, Hongwei Wang b, Fei Pei b, Le Yang c, Xingxing Zhang d, a Beijing Key Laboratory of green built environment and energy efficient technology, Beijing University of Technology, Beijing, 100124, China b Department of Building Environment and Energy Engineering, Beijing University of Technology, Beijing, 100124, China c Department of Building Environment and Energy Engineering, Tsinghua University, Beijng, 100084, China d Department of Energy, Forests and Built Environments, Dalarna University, Falun,79188, Sweden Abstract This paper initially depicted on the energy consumption of air conditioning systems in Beijing subway stations. An investigation was conducted among ten underground subway stations to the examination of practical operation conditions of their cooling units. The overall field testing included information such as air conditioning system formation, equipment types, system operation parameters, energy consumption and system operation efficiency. The results showed that the COP value of refrigerators in the tested subway stations were generally high at about 4.4 in average. Nevertheless, the mean EER and SCOP values were nearly 27% and 48% lower than the average COP value due to the large amount of energy consumption in water pumps, cooling towers and fans. There was a big difference among each station in terms of the instantaneous power consumption of air conditioning systems. The most energy consuming station was nearly seven times higher than the least one. It was observed that there was a lack of maintenance and system operation strategy for these underground air condition systems. A promising potential for energy saving was found out within the air conditioning systems in Beijing subway stations. 2017 The Authors. Published by Elsevier Ltd. Peer-review under responsibility of the scientific committee of the 9th International Conference on Applied Energy. Keywords: subway station ; air conditioning system ; energy consumption * Corresponding author. Tel.: +86-156-5206-9172 E-mail address: pansong@bjut.edu.cn * Corresponding author. Tel.: +46 (0)23 77 8789 E-mail address: xza@du.se 1876-6102 2017 The Authors. Published by Elsevier Ltd. Peer-review under responsibility of the scientific committee of the 9th International Conference on Applied Energy. 10.1016/j.egypro.2017.12.093

Song Pan et al. / Energy Procedia 142 (2017) 2568 2573 2569 Nomenclature COP EER SCOP PSD Qc Pc Pp P T P F Coefficient of Performance of refrigerator Coefficient of Performance of cooling source Coefficient of Performance of air conditioning system Platform Screen Doors system Cooling capacity Instantaneous power consumption of refrigerator Instantaneous power consumption of chilled and cooling water pumps Instantaneous power consumption of cooling towers Instantaneous power consumption of supplying and exhausting fans 1. Introduction In China, the public transportation system has undertaken a rapid development in this decade. Through the government propaganda of energy saving and emission reduction, most people are encouraged to take the public transportations, especially as subway. According to the advanced report from China Association of Metros, there are 26 cities that have the urban rail transit with a total amount of 116 subway lines, almost 3600 km at the end of year 2015. The number of operating subway stations were 2236 in total. There are 13.8 almost billion passengers who chose urban rail transit as their regular traveling tool in 2015. The average daily passenger volume was almost up to 6 million in Beijing, Shanghai and Guangzhou. Moreover, in the next five years, the total distance of new construction subway lines will be beyond 3000km [1]. On the other hand, the increased subway volume requires much more energy for operation. Some research has already reported that part of air conditioning system in the South China could even consume half energy of the total non-traction energy use in summer [2], and the energy consumption may become higher than that due to traction energy use in some extreme condition [3]. Another study highlighted that the air conditioning system consumed 31% energy of the annual subway energy use in Beijing and Shanghai [4]. Obviously, reducing energy consumption of air conditioning systems is one of the most effective ways to tackle high energy demand of subway systems. Currently, most studies only focused on the numerical simulation of air conditioning system in subway stations [6-7]. Their conclusion and recommendation were somehow very limited in terms of validation because of the insufficient field data and measurements. As a result, it is difficult to conclude a general effective energy-saving strategy from the past studies. This paper initially conducted a serious of filed measurements in the summer of 2016, with the aims to investigate the energy consumption and the operational efficiency of air conditioning systems of 10 subway stations in Beijing. The operation condition of running units and the existing technical barriers were summarized. This study may further provide useful guidance towards energy saving in Beijing subway stations. 2. Experimental Set Up and Testing Method This investigation aims to test the real operation condition and system efficiency of air conditioning systems in Beijing subway stations. Through this investigation, the existing operational barriers and energy saving potential of air conditioning system will be identified and evaluated. The testing of 10 subway stations were selected by the Metro Operation Department, from Line 6,7,8,9,10 and 14. Most of the stations were constructed with central cooling units. The detailed information of the stations and their cooling units was shown in Table 1. Table 1. Station and cooling units Station Station form Platform Open time Cooling units A Transfer 2012 B Non-transfer 2012

2570 Song Pan et al. / Energy Procedia 142 (2017) 2568 2573 C Non-transfer 2014 D Non-transfer Side (PSD) 2012 E Non-transfer 2011 Coolant directly expanding F G H I J Transfer Transfer Non-transfer Non-transfer Non-transfer 2011 2012 2012 2012 2014 The selected stations were all equipped with cooling towers except station E. The temperature of cooling water could be directly detected because there was no external insulation layer around the cooling water pipe. The temperature of chilled water was measured through the removal of external insulation layer. Besides, the parameters recorded by refrigerator panel was collected, such as compressor suction and exhaust pressures, units load ratio, inlet and outlet water temperatures. Other parameters, i.e. chilled and cooling water temperatures, instantaneous energy consumption (fans, refrigerators, pumps and cooling towers), and temperature of hall and platform, were measured through dedicated instruments. The detailed testing method was displayed in Table 2. Some field testing photos shown in Fig. 2. Table 2. Testing methods and parameters Testing methods Temperature recorder Ultrasonic flowmeter Power clamp Refrigerator panel Parameters Chilled/cooling water inlet and outlet temperature Chilled and cooling water flux Instantaneous power consumption of refrigerators, fans, pumps, cooling towers Evaporating and condensing temperature/pressure 3. Results and Discussion 3.1. Evaluation theory Fig.1 Field testing photos In this paper, three key parameters [5] are calculated to evaluate the energy efficiency of air conditioning systems. They are the Coefficient of Performance of refrigerator (COP), the Coefficient of Performance of cooling source (EER) (including chilled water pumps, cooling water pumps, cooling towers), and the Coefficient of Performance of whole

Song Pan et al. / Energy Procedia 142 (2017) 2568 2573 2571 air conditioning system (SCOP)(including supplying and exhausting fans). The calculation formulas are presented as follows: COP Q (1) c P c EER Qc P P c P P T (2) SCOP Qc P P P c P T P F (3) where,qq CC is the refrigerating capacity, calculated by the temperature difference between supply and return chilled water.pp CC is the instantaneous power consumption of refrigerator.pp PP represents the instantaneous power consumption of chilled and cooling water pumps. PP TT is the instantaneous power consumption of cooling towers. PP FF is the instantaneous power consumption of supplying and exhausting fans. 3.2. Efficiency of air conditioning systems The testing results for the air conditioning systems in each station is presented in Table 3. It is found that the COP values ranged from 3.0 to 6.0. The average value was 4.4. The lowest value of 3.0 appeared in the subway station I, whereas the peak COP value showed in the station H. The EER values ranged from 2.1 to 4.7 and the average value was 3.2. The highest EER value of 4.7 was found in station D, while the station I had the lowest EER value of 2.1. The SCOP values ranged from 1.1 to 3.6, and the average value was 2.3. Similarly, station I had the minimal value 1.1, while station D and E had the maximal value 3.6. Based on the results above, it can be summarized that the COP values of refrigerators in these subway stations were generally high at about 4.4 in average. Nevertheless, the EER and SCOP values were much lower than COP values because of the great energy consumption of water pumps, cooling towers and fans. Compared with the average COP value, the mean EER and SCOP values was respectively 27% and 48% lower. Table 3. Station and cooling units Station Cooling units Compressors Power/kW Pumps &Towers Power/kW Fans Power/kW Cooling Capacity/kW COP EER SCOP A 323 185 212 1626 5.0 3.2 2.3 B 186 67 150 719 3.9 2.8 1.8 C 192 64 135 817 4.3 3.2 2.1 D 1# 82 19 33 480 5.9 4.8 3.6 2# 66 19 29 341 5.2 4.0 3.0 E Directly expand 103 22 25 540 5.2 4.3 3.6 F 1# 258 143 82 915 3.5 2.3 1.9 2# 141 82 82 615 4.4 2.8 2.0 G 1# 309 154 93 1121 3.6 2.4 2.0 2# 60 26 39 186 3.1 2.2 1.5 H 1# 217 137 84 1303 6.0 3.7 3.0 2# 67 65 38 300 4.5 2.3 1.8

2572 Song Pan et al. / Energy Procedia 142 (2017) 2568 2573 I 1# 177 49 90 712 4.0 3.2 2.3 2# 32 12 43 95 3.0 2.2 1.1 J 1# 207 60 65 773 3.7 2.9 2.3 2# 85 26 33 383 4.5 3.5 2.7 3.3. Instantaneous power consumption Fig. 2 illustrated the instantaneous power consumption of air conditioning system subentry. It could be observed that there was a big difference among each station. The most energy consuming station was seven times higher than the least one. The power consumption of station A, G and H were relatively higher than other stations. Oppositely, Station D and E had much less energy consumption. Considering that station D was built with platform screen doors system (PSD), the heat transfer between tunnel and platform was cut off. Thus, the cooling load was much lower. The coolant directly expanding air conditioning system in station E was also observed as energy-efficient operation. Station A, G and F were transfer stations with larger area than others. However, Station A and G consumed more energy than Station F. This phenomenon revealed that even large station might have feasible energy saving ways when the energy consumption of pumps, cooling towers and fans of some stations were almost the same as the energy consumption of compressors. 800 700 power consumption 600 500 400 300 200 100 0 A B C D E F G H I J stations Refrigerator Pumps and Cooling towers Main System Fans Office System Fans Fig.2 Subentry instantaneous power consumption statistics 3.4. Testing results discussion From the testing results, it was obviously observed the most energy consuming component were compressors. The efficiency of compressor was determined by system type, cooling load and its own running state. Besides, the power of pumps, cooling towers and fans also resulted in the difference between testing stations. Transfer stations with larger area and cooling load like station A, F and G seemed to consume more energy. However, Non-transfer Station B, C, H, I and J were almost the same as F. This phenomenon explained there would be an urgent need to promote the system efficiency for either transfer stations or non-transfer stations. The main reasons causing the energy waste were put forward: Equipment running errors. During the testing, it was found that some refrigerators, pumps and cooling towers were shut down because of running faults. In addition, some meters were lost that resulted in the difficulty of

Song Pan et al. / Energy Procedia 142 (2017) 2568 2573 2573 data collection. Other operational problems, such as transducer faults, oversized pump volume and heat exchanger dirty/scaling, also affected the system efficiency. In general, the facilities were extremely lack of maintenance during the operation. Energy saving strategy absence. The operation modes of refrigerators and cooling towers were not matched with the station cooling load variation. The set temperature of cooling water outlet were slightly lower than standard, which influenced the final COP. 4. Conclusion This paper investigated the operational efficiency and energy consumption of air conditioning system in 10 Beijing subway stations. Through the field testing in these stations, physical parameters, such as temperature, humidity, instantaneous power consumption, were collected. System efficiency (COP, EER, and SCOP) and subentry instantaneous power consumption were calculated. The following conclusions could be drawn: The testing stations reached a normal average COP level of 4.4. The average EER and SCOP value were much lower than COP value due to the huge energy consumption of pumps, cooling towers and fans. It was observed that two stations (D, E) were operated in a condition of low energy consumption and high system efficiency. This is because Station D adopted PSD system and station E were constructed with coolant directly expanding air conditioning system. These two methods may be popularized in other stations. Energy-saving operation strategy and facility maintenance for air condition systems in subways station were highly necessary for further research. Acknowledgements The authors would acknowledge sincere appreciation to the financial supports from National Natural Science Foundation of China (Grant No. 51578011), National Natural Science Foundation of China (Major Program No. 51590912), National Natural Science Foundation of China (General Program No. 51378025), and Beijing University of Technology Science and Innovation Service Capacity Building-Scientific Research Base-Beijing Laboratory-Urban Railway Transportation Beijing Laboratory(participate, municipal). References [1] China Association of Metros. Statistics and analysis of urban rail transit in 2015, China[J]. Urban Rapid Rail Transit, 2016,29(4):6-11. [2] Wang Zijia, Chen Feng & Shi Zhongheng. Study on long term energy consumption prediction of Beijing Urban Rail Transit, China[J]. Railway Science, 2013,34(3):133-136. [3] F. Ampofo, G. Maidment & J. Missenden. Underground Railway Environment in the UK Part 2: Investigation of Heat Load [J]. APPLIED THERMAL ENGINEERING,2004,24(5-6):633-640. [4] Zhu Peigen, Zhu Yingxin & Li Xiaofeng. Scheme and analysis of subway ventilation and thermal simulation [J]. Fluid Machinery, 2004,11:39-42. [5] D. Cutler, J, Winkler, N. Kruis & C. Christensen. Improved Modelling of Residential Air Conditioners and Heat Pumps for energy Calculations [J]. Office of Scientific & Technical Information Technical Reports, 2013,TP-5500-56354. [6] Jonghoon Ahn, Soolyeon Cho, Dae Hun Chung. Development of a statistical analysis model to benchmark the energy use intensity of subway stations [J]. Applied Energy,2016,179: 488 496. [7] Chihping Kuo, Hungjiun Liao. The feasibility of using circulating groundwater as renewable energy sources for air-conditioning in Taipei basin [J]. Renewable Energy, 2012,39:175-182.