DEFLECTION AND WIND LOADS

Similar documents
against falling ( Bauteile, die gegen Absturz sichern ) must be observed.

INSTALLATION MANUAL TRESPA.COM

EASY INSTALLATION, DURABLE DESIGN SMART CLADDING SYSTEM

TS110 Visible (exposed) fixing with screws on an aluminum sub-frame

EASY INSTALLATION, DURABLE DESIGN SMART SIDING SYSTEM

TRESPA METEON EXTERIOR SOCIAL HOUSING FOR TOMORROW

TRESPA TOPLAB SCIENTIFIC SURFACE SOLUTIONS

Installation guidelines for façade applications

Method Statement - Installation Guide KX05 (Trespa TS300)

TS Invisible (concealed) sub-frame

CREATING VALUE THROUGH INNOVATION, EXPERIENCE AND RELIABILITY

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: TRESPA NORTH AMERICA, LTD.

Choosing Between Fire Retardant and Standard Core Metal Composite Material (MCM)

SECTION TRESPA ATHLON SOLID COMPOSITE CASEWORK

TECHNICAL BULLETIN TB-1800-XX. Unsupported Edge Conditions of Insulating Glass Units

Healthcare Solutions

Designing Glass to Resist Wind and Snow Loads

Light + Air Republic of Ireland & UK. Estra Ventilator Data Sheet

Spring Hill Suites Marriott

FIRMLOK FLOORING SYSTEM DESIGN AND INSTALLATION MANUAL

STRUCTURAL GLASS FACADE ALL GLASS FINS & BEAMS

TEST REPORT. Rendered to: TFC A DIVISION OF CENTURION INDUSTRIES, INC. Garrett, Indiana

Code Compliance Research Report CCRR-0228

MATERIALIZING SUSTAINABILITY

110HC SUN LOUVRE. Sun Control Systems

GIB EzyBrace Help. Copyright 8/16 by Winstone Wallboards Ltd. All Rights Reserved.

TRESPA METEON EXTERIOR

RUUKKI FORMA DESIGN INSTRUCTION

The Structural Engineer and Curtain Wall Design. The design of curtain walls entails numerous inputs, including the following

Multi-Institutional Academic Health Science & Research Center Evansville, IN

WALL LINER PRODUCT DATA SHEET FAÇADE & ROOF SYSTEMS

SUSTAINABILITY POSITION PAPER

Series B450 Guide Specification

FLAT TILE HOOK SPAN CHART

PR-L274 Nordic Structures Revised April 16, 2017

Love home, live Trespa live.trespa.com

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: TRESPA NORTH AMERICA, LTD.

Manufacturers declaration of performance

Lexan* Thermoclear* LT2UV166RS27 and LT2UV166RS29 Product datasheet

SOCIAL HOUSING FOR TOMORROW

Report No Originally Issued: 05/2013 Revised: 07/17/2014 Valid Through: 05/2015

Load Design Charts. R-CONTROL SIPs STRUCTURAL INSULATED PANELS. CONTROL, NOT COMPROMISE.

AEROFOILS 200AF-450AF. Sun Control Systems

STEEL SPAN WEIGHT CURVES STEEL BRIDGE RESOURCE

B-RAIL SPAN CHART REPORT

HIGH PRESSURE LAMINATE CLADDING PANELS SPECIFICATION V1.0

LATERAL DRIFT DESIGN IN COLD FORMED STEEL WALL SYSTEMS

Thermal Systems KWC Ltd. Telephone: (403) Avenue N.E. Facsimile: (403)

Flat Slabs. d 2. A typical flat slab (without drop and column head)

ALSPEC ALUMINIUM SYSTEMS TECHNICAL MANUAL

Pilkington Sunplus BIPV Powered by NEXBuilding. Provides power generating solutions for vertical and horizontal applications

RUUKKI FAÇADE SYSTEMS

62 Greene Street Ground Floor New York, NY Tel.: (1) TRESPA,

62 Greene Street Ground Floor New York, NY Tel.: (1) TRESPA

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS SECTION: METAL WALL PANELS REPORT HOLDER:

Composite Steel Deck - Slabs

METEON. Think Trespa. Version 3.1

research report Cold-Formed Steel Gable End Wall Design Using the Prescriptive Method for One and Two Family Dwellings RESEARCH REPORT RP05-2

bondek structural steel deck

ISO INTERNATIONAL STANDARD. Wood-based panels Determination of modulus of elasticity in bending and of bending strength

Exterior Wall Solutions Building Shell

Expanding Your Solutions. ProX Header Rough Opening System

2018 Special-Lite ALUMINUM FRAMING

National Institute of Building Sciences

PART IDENTIFICATION...

Point-Supported Glazing

Technical Report #1. Indiana Regional Medical Center Indiana, PA. Cody A. Scheller. Structural Concepts & Existing Conditions Report

Controlled Environments. Product Data Sheet. Controlled Environment Panel System KS1100 CS

FeliCa Certified Logotype Logotype Guidelines Logotype Usage Regulations

Fire Resistive Design of Exposed Timber Structures

Joint Systems. System No. FF-D-0044

PinkWood Ltd. Revised June 3, 2015

STRUCTURAL CERTIFICATION & SPAN TABLES FOR MCR MOUNTING SYSTEMS

Warmboard-S Radiant-Floor Heating Panels PR-V180 Warmboard, Inc. Revised February 19, 2018

Code Compliance Research Report CCRR-0266

B-RAIL SPAN CHART REPORT

Lexan* Thermoclear* 16mm 5X Multiwall Sheet

STRUCTURAL CERTIFICATION & SPAN TABLES FOR MCR MOUNTING SYSTEMS

STRUCTURAL CERTIFICATION & SPAN TABLES FOR MCR MOUNTING SYSTEMS

STRUCTURAL CERTIFICATION & SPAN TABLES FOR MCR MOUNTING SYSTEMS

Masonry Veneer - Chapter 6. Masonry Veneer Anchored Veneer

SECTION NON--STRUCTURAL METAL FRAMING

RedHeader PRO product catalog STRONGER THAN STEEL. INTERIOR AND EXTERIOR FRAMING

TECHNICAL NOTE On Cold-Formed Steel Construction

Agricultural Hall and Annex East Lansing, MI. Structural Design. Gravity Loads. 1- Based on US Standards

TRESPA WALL CLADDING SYSTEMS SYSTEM 700 ALUMINIUM SUB-FRAME SYSTEM

Global Village Rochester Institute of Technology Rochester, New York

TRESPA METEON EXTERIOR

Architectural Specification Manual

LP OSB Sheathing & Structural 1 Sheathing

METL-VISION WINDOW SYSTEM FOR HORIZONTAL WALL

SECTION R614 STRUCTURAL INSULATED PANEL WALL CONSTRUCTION

Copyright Notice. HCL Technologies Ltd. All rights reserved. A DEFINITIVE GUIDE TO DESIGN FOR MANUFACTURING SUCCESS

The Structurally Glazed Folding System with Exterior All Glass Aesthetic

Code Compliance Research Report CCRR-0234

SECTION ALUMINUM WINDOWS

Joint Evaluation Report ICC-ES (800) (562)

SOTA HYBRID-WALL SPECIFICATION FOR PRE-GLAZED & UNITIZED HYBRID-WALL SYSTEM

Product Guide Specification

TERMS AND CONDITIONS FOR INTERCEDE PRODUCTS AND SERVICES

Transcription:

DEFECTION AND WIND OADS This document is intended to provide general recoendations only. Trespa provides these guidelines and all testing, code and design data for informational purposes only and strongly advises that the customer, project owner and architect seek independent advice from a certified construction professional and/or engineer regarding application and installation as well as compliance with design requirements, applicable codes, laws and regulations, and test standards. Please check your local codes and applicable design requirements for proper use. General There are numerous factors to consider when designing and installing Trespa Meteon panels. Panel appearance, joint solution, cavity depth, drainage/ventilation performance and ease of installation are some important considerations. However, the most important characteristics are panel strength and panel fixing (anchor) design: 防 Panel resistance to deflection and stress due to wind loading. 防 oad transfer (wind and dead load) via panel anchors to the sub-frame. 防 oad transfer through the sub-frame to the building structure. This document will focus primarily on the ability of Trespa Meteon to resist wind load deflection and provide charts to aid in panel fixing distances (anchor spacing). Design considerations 防 Wind loads, fixing distances and panel deflection have to be calculated by a construction professional. The customer, project owner and architect must always seek independent advice from a certified construction professional and/or engineer regarding the accordance to national and/or local building regulations and certificates. Trespa does not make any representations as to the implications of using a specific fixing system and disclaims any and all liability or damages related thereto. 防 Any modification to Trespa panels or components thereof, its geometry or its specifications, and any use or installation of Trespa panels or fixing system in combination with any material or component other as advised by Trespa, shall be exclusively at the risk of the parties involved in such modification, use or installation, and each of such parties assumes all such risks. 防 Structural performance is an important criteria in the design of a panel system for both aesthetic and structural compliance reasons. 防 One of the interesting benefits of Trespa Meteon panels used as exterior cladding is the ability to resist wind loading and remain flat. This capacity to resist deflection is determined by a number of factors including panel thickness, mechanical properties and the distance between panel fixings (panel anchors). 防 oad bearing of panels, supports and fixings included, has to take place in such a way that maximum loads do not exceed admitted strengths. 1

Technical details panel deflection 防 Allowable panel deflection is often the controlling factor when designing panel installations, although other considerations may impact the adequacy of the design. All design considerations should be evaluated prior to completion of a final panel system. 防 A panel s permissible deflection ( ) is governed by national and/or local building regulations. The maximum allowable panel deflection ( max) represents the distance the panel is allowed to deflect (or bend ) and return to a flat position without affecting structural integrity. In Europe, the maximum allowable panel deflection ( max) coonly used is /200. In the United States, the maximum allowable panel deflection ( max) for semi-rigid exterior cladding is /175 or ¾, whichever is less. This value is derived from the max used for glass and glazing (IBC 2006 Section 2403.3) 防 A minimum (wind) load must be taken into account to prevent the façade structure from not meeting design and appearance expectations. 防 In order to provide the user a general overview of maximum fixing distances (anchor spacing) based on the standard panel thicknesses of Trespa Meteon, the following graphs have been developed based on two general panel installation conditions: Single span; two support points in height and/or width. Multiple span; three or more support points in height and/ or width. Panel deflection /200 防 The graphs below show panel spans for Trespa Meteon panel thicknesses from 6 to 13 for different wind loads and a maximum panel deflection of /200 (coonly used in Europe). 防 The maximum permitted panel spans can be found on the horizontal axis for a minimum wind load of 600 N/ m². Higher wind loads will reduce the panel spans according to the graph. 防 These charts are intended to provide only a general overview of panel deflection design considerations. Each project must be engineered by a construction professional as required. code U3074 version 2.0 date 14-06-2011 2

Single span Panels are often installed with only two support points in height and/or width. This allows the panel to deflect between these two points. The curves shown on the following graph identify the spacing of the panel fixings (panel anchors) and associated wind load resistance that meet the deflection criteria /200 for panels installed using a single span. Deflection for 2-supports (f=/200) 2.100 2.000 1.900 1.800 1.700 Wind load (N/m 2 ) 1.600 1.500 1.400 1.300 1.200 1.100 1.000 900 800 700 600 6 8 300 400 500 600 700 800 900 1000 1100 1200 350 450 550 650 750 850 950 1050 1150 Panel span () 3

Multiple span More often, three or more support points are required in width and/or height. The deflection for these panels is a complex combination of influences from each of the multiple spans. The curves shown on the following graph identify the spacing of the panel fixings (panel anchors) and associated wind load resistance that meet the deflection criteria /200 for panels installed with multiple spans. Deflection for more than 2-supports (f=/200) 2.100 2.000 1.900 1.800 1.700 Wind load (N/m 2 ) 1.600 1.500 1.400 1.300 1.200 1.100 1.000 900 800 700 6 8 600 300 400 500 600 700 800 900 1000 1100 1200 350 450 550 650 750 850 950 1050 1150 Panel span () code U3074 version 2.0 date 14-06-2011 4

Panel deflection /175 Single span Panels are often installed with only two support points in height and/or width. This allows the panel to deflect between these two points. The curves shown on the following graph identify the spacing of the panel fixings (panel anchors) and associated wind load resistance that meet the deflection criteria /175 for panels installed using a single span. 40 38 Deflection for 2-supports (f=/175) Wind load (PSF) 36 34 32 30 28 26 24 6 8 1/4 in 5/16 in 3/8 in 1/2 in 22 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 Panel span (in) Multiple span More often, three or more support points are required in width and/or height. The deflection for these panels is a complex combination of influences from each of the multiple spans. The curves shown on the following graph identify the spacing of the panel fixings (panel anchors) and associated wind load resistance that meet the deflection criteria /175 for panels installed with multiple spans. 40 38 36 Deflection for more than 2-supports (f=/175) Wind load (PSF) 34 32 30 28 26 24 22 14 6 1/4 in 8 5/16 in 3/8 in 1/2 in 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 Panel span (in) 5

Disclaimer This is a print generated by you from www.trespa.info ( Website ). By accessing the Website and printing this document you have accepted the Terms of Use of the Website. Please refer to the Website for all conditions that apply to this document. Not all the systems shown in this document may be suitable for all applications and jurisdictions. We provide you with testing, code and design data for informational purposes only and strongly recoend that you or any other user of this document obtains independent advice regarding compliance with design requirements, applicable codes, laws and regulations, and test standards. Please check your local codes and design requirements for proper use. Trespa will not accept any liability in relation to your use of this document. All intellectual property rights, including copyrights and other rights regarding the content of the Website and this print generated from the Website (including logos, trademarks, service marks, software, databases, audio, video, text and photographs) are owned by Trespa and/or its licensors. Trespa, Meteon, Athlon, Topab, Topab PUS, Topab ECO-FIBRE, Virtuon, Volkern, Trespa Essentials and Mystic Metallics are registered trademarks of Trespa. All oral and written statements, offers, quotations, sales, supplies, deliveries and/or agreements and all related activities of Trespa are governed by the Trespa General Terms and Conditions of Sale (Algemene verkoopvoorwaarden Trespa International B.V.) filed with the Chamber of Coerce and Industry for Noord- en Midden- imburg in Venlo (N) on 11 April 2007 under number 24270677,which can be found on and downloaded from the Trespa website, www.trespa.com. All oral and written statements, offers, quotations, sales, supplies, deliveries and/or agreements and all related work of Trespa North America, td. code U3074 version 2.0 date 14-06-2011 are governed by the Trespa General Terms and Conditions of Sale, which can be found on and downloaded from the Trespa North America td. website, www.trespa.com/na. A copy of these general conditions of sale will be provided free of charge on request. 6