User Manual PM600. Laser Fiber Power Meter

Similar documents
Quick Start Guide WaveMaster

Instructions and E00 Series Sampling Module Extenders

Global Water Instrumentation, Inc.

Saphyr System Safety Guide for Saphyr P/N 60325

T1000 Transformer INSTRUCTION SHEET. for Magnetic-Field Susceptibility Testing. Features

Xxxxx Xxxxxx OM-CP-TEMP101A. Temperature Data Logger with 10 year battery life INSTRUCTION SHEET MQS5026/0117

FO-6000 Inline FO Filter Holder FO-6000FILT INSTRUCTION MANUAL. Serial No. World Precision Instruments

INSTALLATION & OPERATION INSTRUCTIONS ICW-3 WINDOW INTERCOM

Agilent 16047D Test Fixture

USER'S GUIDE TO OPERATION

Thermoelectric Coolers. All Models INSTRUCTION MANUAL. Rev. G 2016 Pentair Equipment Protection P/N

Agilent 16048D Test Leads

Owner s Manual & Safety Instructions

Agilent 16048B Test Leads Operating Note Third Edition Agilent Part No May 2000

Thermoelectric Cooler

DICKSON TH8 DICKSON. Temperature & Humidity Chart Recorder Operation. Useful Features. Applications & Product. Specifications. Product.

10810 W. LITTLE YORK RD. #130 - HOUSTON, TX VOICE (713) FAX (713) web: IMPORTANT!!!

MODELS MB1K-1, MB1K-2 MB2K-1, MB2K-2 MB3K-1, MB3K-2

Operation and Service Manual

Model E100 Gauss Meter

Keysight 16380C Capacitance Standard Set

Qualstar Technical Support

Model 292A. Surface Resistance Test Kit. Instruction Manual

PalletPal Low Profile Disc Turntable

Sby SR Instruments, Inc.

Rack Power Distribution Unit AP7562, AP7563, AP7564 General Information

TrueClean ToteTilter TM

Agilent 16034E Test Fixture

4-Wire Buffer Amplifier. User Manual

Model 10A. Model 20A. Operating Manual. ECG Simulator. ECG / Arrythmia Simulator

TEST & MEASUREMENT TOOL LIMITED WARRANTY Every Test & Measurement Tool is warranted for five (5) years from the date of purchase *.

XBDM-HW63. 63A Model. User & Installation Manual Xtreme Power Conversion Corporation. All rights reserved.

Model M120 Mini Temperature/Humidity Meter

Installation Guide Document No Transaction Windows Copyright 2017 Terra Universal Inc. All rights reserved. Revised October 2017

CHECK LINE. Operating Instructions BY ELECTROMATIC STM-50

1.0 STS-WiFi Operations Manual Outline

Installation. Basic Rack Power Distribution Units AP9560 AP9561

Global Water globalw.com. Global Water. Instrumentation, Inc.

10810 W. LITTLE YORK RD. #130 - HOUSTON, TX VOICE (713) FAX (713) web: IMPORTANT!!!

HDI 2200 Choke Position Indicator

6 Closet light. Model Due to continuing improvements, actual product may differ slightly from the product described herein.

ENMET Corporation PO Box 979 Ann Arbor, MI GS-24-DF. Manual October 2003 MCN-314, 12/05/03

This product has been tested and certified to conform to ASTM F2456, Youth Resistant Firearms Container.

OPTO BRANCH 6 RJ45. user manual. ELATION OPTO BRANCH 6 RJ45 user manual

Model HH Signal-Conditioner / Indicator

LA LM56HRS1. Hyper red Laser Diode (661 nm), Multi Mode. Important Safety Advice

4300 WINDFERN RD #100 HOUSTON TX VOICE (713) FAX (713) web: twrlighting.com IMPORTANT!!!

Installation Guide Document No BioSafe Cleanroom Windows Copyright 2017 Terra Universal Inc. All rights reserved. Revised December 2017

Owner s Manual & Safety Instructions

Instruction Manual. YieldPoint Inc. Jan 2011

Miniglaze/2. Owner & Operator's Manual PORCELAIN STAINING AND GLAZING FURNACE. Model No: Voltage: V 50/60Hz V 50/60Hz

Model T2642E Wall Mount. Television Wall Mount with Tilt Option

Continuous Wave Single Frequency Lasers. SCHERZO Series. 532nm 300mW

OM-CP-QUADPROCESS 4-Channel Low Level DC Current Data Logger. OM-CP-OCTPROCESS 8-Channel Low Level DC Current Data Logger INSTRUCTION SHEET

LA LM56UXS1. Near Ultraviolet Laser Diode (406 nm), Multi Mode. Important Safety Advice

CDM Network Programmer for CCT100x

C60 Standby UPS. 800VA Models. User & Installation Manual Xtreme Power Conversion Corporation. All rights reserved.

TF-XGbT Compliance Test Fixture (For use with TekExpress XGbT-10GBASE-T Automated Solutions) Reference

PD6770 VANTAGEVIEW LOOP-POWERED PROCESS METER

Continuous Wave Single Frequency Lasers. SYMPHONY Series. 532nm 2000mW

LA LS56HRC1. Hyper red Laser Diode (660 nm), Single Mode. Important Safety Advice

WARRANTY GENERAL POLICY AND RETURN GOODS PROCEDURE. For Original Equipment Manufacturers Only

LA LS56CYS1. Cyan Laser Diode (488 nm), Single Mode. Important Safety Advice

User Manual. PAT-Stand-16 Docking Station. Release 1.3. November EL-CELL GmbH

TABLE OF CONTENTS. Section Paragraph Title Page. ADDENDUM Visual Index Quick Reference. 1 General Information 1-1

Circular Expansion Cement Curing Kit Instruction Manual

Daniel TM Ultrasonic Flow Meters

Tube Revolver. Catalog # & Operation Manual User Manual

Daniel Orifice Fittings and Meter Tubes

Dandy Leveler UDLV-150 & UDLV-500 (New Style)

Oyster ph - Conductivity - TDS - Temperature Meters

OptoLum MegaLine RGBW Luminaire

Quick-Start Operating Guide Document No Process Gas Cooler Copyright 2010 Terra Universal Inc. All rights reserved. Revised October 2010

Locking Systems International Inc.

SAVE THESE INSTRUCTIONS

E3X-DRT21/SRT21/CIF11

1.1 Defined Terms. As used in this Policy, the following terms have the indicated meanings:

Installation Guide Document No Fire-Rated Pass-throughs Copyright 2017 Terra Universal Inc. All rights reserved. Revised Sept.

CM-v-3 module. GSM/GPRS/EDGE communication module for MT880 meters. Technical description

RAPiD Safe Setup and Operation

Elevation Station MODEL: ES.02-16

Phase One Classic Warranty

10810 W. LITTLE YORK RD. #130 - HOUSTON, TX VOICE (713) FAX (713) web: IMPORTANT!!!

P1902 Installation Manual

PAGODA SERIES OPERATOR'S MANUAL

AQUA UNO TUB DOOR INSTALLATION INSTRUCTIONS

J60 Lithium Ion UPS 350VA Model User & Installation Manual Xtreme Power Conversion Corporation. All rights reserved.

UNI BAR. user manual. ELATION UNI BAR user manual

NetShelter. Four-Post Rack. Installation and Quick-Start Manual

92831 TEL: (714) FAX:

Elveflow Flow Reader

SelfCheck System R-Series. Site Planning Guide

Model K11. 10ppm Accuracy DC Voltage Standard. Operating Manual

General Safety Information

Mechanical Post Lift. Owner s Manual

L505 VISUAL LEVEL INDICATOR. Dip-Tape Visual Level Indicator INSTALLATION AND OPERATIONS MANUAL

General Warranty Information, Policies & Guidelines

XBLUE NETWORKS WARRANTY AND CUSTOMER SERVICE POLICY AND PROCEDURES

MiT. MOVING image TECHNOLOGIES INSTRUCTIONS FOR INSTALLATION, OPERATION, AND MAINTENANCE. MPL Digital Pedestal. Manual Version 0.2

Global Water Instrumentation, Inc.

Transcription:

User Manual PM600 Laser Fiber Power Meter

User Manual PM600 Laser Fiber Power Meter 7470 SW Bridgeport Rd. Portland, OR 97224

PM600 User Manual This document is copyrighted with all rights reserved. Under the copyright laws, this document may not be copied in whole or in part or reproduced in any other media without the express written permission of Coherent, Inc. Permitted copies must carry the same proprietary and copyright notices as were affixed to the original. This exception does not allow copies to be made for others, whether or not sold, but all the material purchased may be sold, given or loaned to another person. Under the law, copying includes translation into another language. Coherent and the Coherent Logo are registered trademarks of Coherent, Inc. PM600 is a trademark of Coherent, Inc. Every effort has been made to ensure that the data given in this document is accurate. The information, figures, tables, specifications and schematics contained herein are subject to change without notice. Coherent makes no warranty or representation, either expressed or implied with respect to this document. In no event will Coherent be liable for any direct, indirect, special, ii

incidental or consequential damages resulting from any defects in its documentation. In the U.S.: Technical Support Should you experience difficulties with your product, or need technical information, please visit our website: www.coherent.com. You can obtain additional support by either telephoning our Technical Support Hotline at 1.800.343.4912, or e-mailing our Support Team at support.instruments@coherent.com. Telephone coverage is available Monday through Friday (except U.S. holidays). If you call outside our office hours, your call will be taken by our answering system and will be returned when the office reopens. iii

PM600 User Manual If there are technical difficulties with your product that cannot be resolved by support mechanisms outlined above, please e-mail or telephone Coherent Technical Support with a description of the problem and the corrective steps attempted. When communicating with our Technical Support Department, via the web or telephone, the model and serial number of the product will be required by the Support Engineer responding to your request. Outside the U.S.: If you are located outside the U.S., visit our website for technical assistance, or telephone our local Service Representative. Representative phone numbers and addresses can be found on the Coherent website: www.coherent.com. Coherent provides web and telephone technical assistance as a service to its customers and assumes no liability thereby for any injury or damage that may occur contemporaneous with such services. These support services do not, under any circumstances, affect the terms of any warranty agreement between iv

Coherent and the buyer. Operating a Coherent product with any of its interlocks defeated is always at the operator's risk. v

PM600 User Manual vi

Table of Contents TABLE OF CONTENTS Preface... xi U.S. Export Control Laws Compliance... xi Publication Updates...xii Symbols Used in This Document... xiii Safety...1 Declaration of Conformity...5 Description...7 vii

PM600 User Manual Features...9 Controls...9 POWER Switch...9 ZERO ADJUST Control...9 LCD...9 Numeric Readout...9 LOW BATTERY Indicator...10 Fiber Input...11 FIBER INPUT Port...11 Removable Window...11 Battery...13 Operation...15 viii

Table of Contents Maintenance...19 Calibration and Warranty...21 Calibration...21 Coherent Calibration Facilities and Capabilities...21 Limited Warranty...23 Extended Lifetime Warranty...24 Warranty Limitations...26 Obtaining Service...27 Product Shipping Instructions...30 Specifications...33 ix

PM600 User Manual LIST OF TABLES 1. Coherent Service Centers...29 2. Specifications...33 x

Preface Preface U.S. Export Control Laws Compliance This manual contains user information for the PM600 laser fiber power meter. It is the policy of Coherent to comply strictly with U.S. export control laws. Export and re-export of lasers manufactured by Coherent are subject to U.S. Export Administration Regulations, which are administered by the Commerce Department. In addition, shipments of certain components are regulated by the State Department under the International Traffic in Arms Regulations. The applicable restrictions vary depending on the specific product involved and its destination. In some cases, U.S. law requires that U.S. Government approval be obtained prior to resale, export or re-export of xi

PM600 User Manual Publication Updates certain articles. When there is uncertainty about the obligations imposed by U.S. law, clarification should be obtained from Coherent or an appropriate U.S. Government agency. To view information that may have been added or changed since this publication went to print, connect to www.coherent.com. xii

Preface Symbols Used in This Document This symbol is intended to alert the operator to the presence of dangerous voltages associated with the product that may be of sufficient magnitude to constitute a risk of electrical shock. This symbol is intended to alert the operator to the presence of important operating and maintenance instructions. xiii

PM600 User Manual xiv

Safety SAFETY Carefully review the following safety information to avoid personal injury and to prevent damage to this instrument or any sensor connected to it. There are no user-serviceable parts in the PM600 laser fiber power meter. For service information, refer to Obtaining Service on page 27. Use only the power cord specified for the meter. The grounding conductor of the cord must be connected to earth ground. 1

PM600 User Manual Do not operate the meter if its panels are removed or any of the interior circuitry is exposed. Do not operate the meter in wet or damp conditions, or in an explosive atmosphere. 2

Safety Operate the meter only within the specified voltage range. Do not apply a voltage outside the specified range of the input connections. 3

PM600 User Manual Do not operate the meter if there are suspected failures. Refer damaged units to qualified Coherent service personnel. 4

Safety Declaration of Conformity 5

PM600 User Manual 6

Description DESCRIPTION The PM600 laser fiber power meter is a complete laser power system contained in a compact, battery-operated enclosure. The instrument combines an advanced-technology laser disk, low-noise, solid-state electronics, and a high-contrast, 3½-digit LCD display. Its large input port accepts the fiber output from a CW or pulsed laser and displays power in watts. The instrument is designed to provide a simple, accurate method of measuring laser fiber condition and system performance. The PM600 can also be fitted with a standard SMA fiber connector in place of the window, making a fiber cable connection possible.the instrument features a POWER switch, ZERO ADJUST control, and LOW BATTERY indicator, and can be set up and ready to take power measurements in a matter of seconds. 7

PM600 User Manual 8

Features FEATURES Controls POWER Switch ZERO ADJUST Control LCD Numeric Readout The side-mounted POWER switch turns the PM600 ON and OFF. The side-mounted ZERO ADJUST control allows the user to zero the LCD before taking a measurement. The 3½-digit liquid crystal display provides digital readout directly in watts. The PM600 can display up to 19.99 watts, but was designed for use with 3-watt lasers. 9

PM600 User Manual LOW BATTERY Indicator The LCD displays the LO BAT indicator when the battery voltage drops below a usable level (see Battery on page 13). Accurate readings cannot be made when the LO BAT indicator is activated. 10

Features Fiber Input FIBER INPUT Port The FIBER INPUT port is a 9 mm window, designed to prevent the laser fiber from coming too close to the sensor disk inside the instrument. Although touching the window with the laser fiber will not damage the PM600, it is recommended that measurements be made with the fiber held 1 / 16 to 3 / 16 above the surface of the window. Removable Window The window assembly is removable from the instrument. Windows of different material are available for use with a variety of laser wavelengths. SMA connector adapters are also available. 11

PM600 User Manual To remove the window, use a small, flathead screwdriver to carefully pry the outer edge of the window upward (see the following illustration). To install a window, drop the window into the hole on the PM600 and then press downward on the window until it snaps into place. 12

Features Battery The battery is located in a compartment on the bottom of the instrument enclosure. To access the battery, press down on the compartment cover while sliding it outward, away from the center of the enclosure. When the LO BAT indicator appears on the LCD, replace the battery with a standard 9V transistor battery. 13

PM600 User Manual 14

Operation OPERATION The following section describes a typical setup and procedure for using the PM600: 1. Switch the PM600 power ON, and wait for 5 seconds for the display to stabilize. 2. Verify that the LO BAT indicator does not appear in the LCD window. 3. Use the ZERO ADJUST control to obtain a 0.00 reading on the LCD. 4. With the laser powered up, and the foot pedal not depressed, place the fiber near the center of the PM600 FIBER INPUT port. Main- 15

PM600 User Manual tain a close-to-perpendicular angle between the window and the fiber. The laser output can damage the front surfaces of the PM600. While making power measurements, depress the laser foot pedal only when the fiber is placed perpendicular near the center of the PM600 FIBER INPUT port. 5. Depress the laser foot pedal to transmit laser power through the fiber. 6. Watch the PM600 LCD until the reading stabilizes (approximately 6 sec.). 16

Operation 7. Read laser power in watts. 8. Release the laser foot pedal, and switch the PM600 power OFF. 17

PM600 User Manual 18

Maintenance MAINTENANCE The PM600 contains no user-serviceable parts other than a standard 9V transistor battery (see Battery on page 13). The input window port can be cleaned with most cleaning solvents, including window cleaner and alcohol. Stronger, industrial solvents such as acetone can be used on the window, but care must be taken not to expose the plastic parts of the instrument to the stronger solvents. 19

PM600 User Manual 20

CALIBRATION AND WARRANTY Calibration and Warranty Calibration Coherent Calibration Facilities and Capabilities Coherent laser power and energy meters are precision instruments, capable of delivering very accurate measurements, as well as providing many years of useful service. To maintain this high level of performance, it is important to have your measurement system serviced and recalibrated once a year. As the largest laser manufacturer in the world, Coherent has been able to build state-of-the-art calibration facilities containing the widest possible range of laser types and technologies. This enables us to perform instrument and sensor calibration under virtually any combination of wavelength, power, and operating characteristics. Sensors are calibrated against NIST-traceable working standard sensors which are, 21

PM600 User Manual in turn, calibrated against NIST-calibrated golden standard sensors. These working and golden standards are maintained with the utmost care, recalibrated annually, and verified even more regularly. We maintain multiple NIST-calibrated standards at many laser wavelengths to support the growing calibration needs of our customers. Optical calibration is a core competency at Coherent and we strive to continually improve our methods, precision, and repeatability. Additionally, most of the calibrations are performed with highly automated systems, thus reducing the possibility of human error to nearly zero. Strict quality inspections during many stages of calibration and testing assure a precise and accurate instrument that is NIST traceable and CE marked. The benefit to our customers is that instruments calibrated by Coherent 22

Calibration and Warranty Limited Warranty will consistently perform as expected under their actual use conditions. We are registered to ISO 9001:2000, our products are NIST traceable, and our calibration labs are fully ANSI Z540 compliant. In addition to the technological advantage, we also strive to deliver the best service in the industry, with a knowledgeable and responsive staff, and rapid turnaround. Coherent, Inc. (the Company ) warrants its laser power and energy meters and sensors products ( Products ) to the original purchaser (the Customer ) that the product is free from defects in materials and workmanship and complies with all specifications, active at the time of purchase, for a period of twelve (12) months. 23

PM600 User Manual Extended Lifetime Warranty Coherent, Inc. will, at its option, repair or replace any product or component found to be defective during the warranty period. This warranty applies only to the original purchaser and is not transferable. Coherent, Inc. (the Company ) offers original purchasers (the Customer ) purchasing laser power and energy meters and sensors products ( Products ) an extended, lifetime warranty program, which includes all parts and labor. In order to qualify for this warranty, a Customer must return the Product to the Company for recalibration and recertification (traceable to NIST and MIL-STD-45662A) within one year from the date of purchase, and annually thereafter. The Company will recertify the Product, provide software upgrades, and perform any needed repairs, for a fixed service fee (as established by the Company from time to time and in effect at the time of service). 24

Calibration and Warranty If the Product fails and is returned to the Company within one year following the date of recalibration service, the Company will, at its option, repair or replace the Product or any component found to be defective. This warranty applies only to the original purchaser and is not transferable. If the Product is not returned for recalibration or service prior to the one-year anniversary, the lifetime warranty program expires. The lifetime warranty program may be reinstated, at Coherent's option, after completion of a fee-based product evaluation and repair, and subsequent recalibration and recertification service. 25

PM600 User Manual Warranty Limitations The foregoing warranties shall not apply, and Coherent reserves the right to refuse warranty service, should malfunction or failure result from: Damage caused by improper installation, handling, or use Laser damage (including sensor elements damaged beyond repair) Failure to follow recommended maintenance procedures Unauthorized product modification or repair Operation outside the environmental specifications of the product Coherent assumes no liability for Customer-supplied material returned with Products for warranty service or recalibration. 26

Calibration and Warranty Obtaining Service THIS WARRANTY IS EXCLUSIVE IN LIEU OF ALL OTHER WARRANTIES WHETHER WRITTEN, ORAL, OR IMPLIED. COHERENT SPECIFICALLY DISCLAIMS THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT SHALL THE COMPANY BE LIABLE FOR ANY INDIRECT, INCIDENTAL, OR CONSE- QUENTIAL DAMAGES IN CONNECTION WITH ITS PRODUCTS. In order to obtain service under this warranty, Customer must notify the Company of the defect before the expiration of the warranty period and make suitable arrangements for the performance of service. The Company shall, in its sole discretion, determine whether to perform warranty service at the Customer's facility, at the Company's facility, or at an authorized repair station. 27

PM600 User Manual If Customer is directed by the Company to ship the product to the Company or a repair station, Customer shall package the product (to protect from damage during shipping) and ship it to the address specified by the Company, shipping prepaid. The customer shall pay the cost of shipping the Product back to the Customer in conjunction with annual recalibration and repair; the Company shall pay the cost of shipping the Product back to the Customer in conjunction with product failures within the first twelve months of time of sale or between annual recalibrations. A Returned Material Authorization number (RMA) assigned by the Company must be included on the outside of all shipping packages and containers. Items returned without an RMA number are subject to return to the sender. 28

Calibration and Warranty For the latest Customer Service information, refer to our website: www.coherent.com. Detailed instructions on how to prepare a product for shipping are shown under Product Shipping Instructions on page 30. Table 1. Coherent Service Centers LOCATION PHONE FAX E-MAIL USA 1.800.343.4912 971.327.2777 info_service@coherent.com Europe +49-6071-968-0 +49-6071-968-499 info_service@coherent.com International 971.327.2700 971.327.2777 info_service@coherent.com 29

PM600 User Manual Product Shipping Instructions To prepare the product for shipping to Coherent: 1. Contact Coherent Customer Service (refer to Table 1, Coherent Service Centers, on page 29) for a Return Material Authorization number. 2. Attach a tag to the product that includes the name and address of the owner, the person to contact, the serial number, and the RMA number you received from Coherent Customer Service. 3. Wrap the product with polyethylene sheeting or equivalent material. 4. If the original packing material and carton are not available, obtain a corrugated cardboard shipping carton with inside dimensions that are at least 6 in. (15 cm) taller, wider, and deeper than the 30

Calibration and Warranty product. The shipping carton must be constructed of cardboard with a minimum of 375 lb. (170 kg) test strength. Cushion the instrument in the shipping carton with packing material or urethane foam on all sides between the carton and the product. Allow 3 in. (7.5 cm) on all sides, top, and bottom. 5. Seal the shipping carton with shipping tape or an industrial stapler. 6. Ship the product to: Coherent, Inc. 7470 SW Bridgeport Rd. Portland, OR 97224 Attn: RMA # (add the RMA number you received from Coherent Customer Service) 31

PM600 User Manual 32

Specifications SPECIFICATIONS Table 2. Specifications Spectral Response Power Range Max. Recommended Continuous Power Max. Stable Reading at 3W Typical Response Time Display 350 to 2100 nm 100 mw to 10W (10 sec. duration) 1W 30 sec. 6 sec. 3 1 / 2 -digit LCD 33

PM600 User Manual Table 2. Specifications (Continued) Fiber Input Aperture Battery Type Battery Life Alkaline Heavy Duty Carbon-Zinc Size (h x w x d) Accuracy 9 mm or SMA connector 9V transistor battery 100+ hr. 75+ hr. 50+ hr. 14.6 x 9.3 x 5.6 cm (5.75 x 3.65 x 2.20 in.) ± 5% NIST traceable Repeatability ± 1% 34

PM600 User Manual Coherent, Inc. 1/2005, Printed in the U.S.A. Part No. 0980-0220-0, Rev. AB