SECTION SUSPENDED MAINTENANCE ANCHORAGE SYSTEM

Similar documents
SECTION STRUCTURE MOUNT RAILING SYSTEM

DIVISION [11014] SUSPENDED MAINTENANCE AND FALL PROTECTION EQUIPMENT

SECTION PORTABLE RAILING SYSTEM

SECTION SUSPENDED ACCESS SUPPORT EQUIPMENT AND FALL RESTRAINT EQUIPMENT

DBI-SALA Uni 8 Horizontal Lifeline Cable System

SECTION LATCHWAYS CONSTANT FORCE POSTS

DBI-SALA Uni 8 Overhead Horizontal Lifeline Cable System SECTION HORIZONTAL FALL PROTECTION - OVERHEAD CABLE

SECTION HORIZONTAL FALL PROTECTION RAIL

SECTION ORCHESTRA PIT FILLER

A. ANSI A10.32, "Personal Fall Protection Used in Construction and Demolition Operations."

1. Base plates, setting plates and anchor rods for columns. 8. Lintels if connected to structural steel columns.

SECTION FABRICATED ENGINEERED STRUCTURES. A. Pre-engineered, shop-fabricated structural steel building with formed purlin framing.

METAL LADDERS (LADDER SAFETY GATE FALL PROTECTION)

SECTION HANDRAILS AND RAILINGS. A. Section Metal Fabrications: Associated metal supports.

K. ASTM F436- Standard Specification for Hardened Steel Washers; 2011.

SECTION METAL FABRICATIONS FOR STEAM UTILITY DISTRIBUTION

SECTION METAL STAIRS

SECTION HANDRAILS AND RAILINGS. A. Section Cast-In-Place Concrete; coordination with substrate.

SPECIFICATION SECTION 05515: LADDERS O Keeffe s Aluminum Ladders

SECTION STRUCTURAL STEEL FRAMING

Multi-Institutional Academic Health Science & Research Center Evansville, IN

STRUCTURAL STEEL FRAMING

SECTION METAL STAIRS

SECTION INDUSTRIAL ACCESS / INSPECTION HATCH. A. Industrial Access / Inspection Hatch: Model AH-710

SECTION COLD-FORMED METAL TRUSSES

SECTION ORNAMENTAL ALUMINUM RAILING

SECTION ARCHITECTURAL ORNAMENTAL HANDRAILS AND RAILINGS Casino Modular Railing System

A. American Society for Testing and Materials (ASTM):

Home Depot Page 1 of 5 HDPB Humacao, PR 10/19/09

Trex Commercial Products page Metal Railing

American Metal Specialties, Inc.

SECTION STRUCTURAL STEEL

DIVISION 5 METALS SECTION STRUCTURAL STEEL

WALL CANTILEVER WORK STATION JIB CRANE

SECTION HANDRAILS AND RAILINGS. Display hidden notes to specifier. (Don't know how? Click Here)

SECTION ROOF EDGE SAFETY RAILING SYSTEM

TCC/SHORE TRANSIT BUS MAINTENANCE FACILITY - PHASE II

Keuka Studios May 2008 SECTION {05720} CABLE RAILING SYSTEM {CABLE RAILING SYSTEM} Display hidden text for Specifier Notes.

This guide can be used to prepare a specification for incorporating free standing jib cranes into a competitively bid construction project.

A. OSHA 1910, Subpart D, Fixed Industrial Ladders. C. ANSI A14.3, Safety requirements for Fixed Ladders

SECTION SECTIONAL OVERHEAD DOORS

SECTION ORNAMENTAL ALUMINUM RAILING

SECTION ARCHITECTURAL GLASS HANDRAIL AND RAILINGS

SECTION HANGERS AND SUPPORTS FOR ELECTRICAL SYSTEMS

1.02 SYSTEM DESCRIPTION

1.02 SYSTEM DESCRIPTION

SECTION DECORATIVE METAL RAILINGS

SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

SECTION METAL FABRICATIONS

C. Preparation and submission of complete engineered shop drawings for approval. E. Coordination with other affected work, trades and inspections.

SECTION STRUCTURAL METAL FRAMING

CEILING MOUNTED ARTICULATING JIB CRANE

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

SECTION (16071) - VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

SECTION VIBRATION AND SEISMIC CONTROLS FOR HVAC PIPING AND EQUIPMENT

SECTION ORNAMENTAL WELDED STEEL FENCING

SHORING & UNDERPINNING 02250

SECTION SECURITY GRILLES 679 SERIES SUPERGARD SIDE FOLDING GRILLE

DIVISION 07 - THERMAL & MOISTURE PROTECTION

C. Preparation and submission of complete engineered shop drawings for approval. E. Coordination with other affected work, trades and inspections.

SECTION OVERHEAD COILING FIRE DOORS MODEL 662 OVERHEAD COILING COUNTER FIRE DOORS WITH INTEGRAL FRAME

This guide can be used to prepare a specification for incorporating wall bracket jib cranes into a competitively bid construction project.

SECTION METAL DECKING. A. Extent of metal decking is indicated on Plans, including basic layout for the following type of deck required:

Insulating Cellular Concrete Steel Joists Painting. A. America Society for Testing and Materials (ASTM):

SECTION VERTICAL MEZZANINE GATE U.S. Patent No:

SECTION [ ] COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

SECTION ARCHITECTURAL ORNAMENTAL HANDRAILS AND RAILINGS Glenlake Modular Railing System

WALL MOUNTED ARTICULATING JIB CRANE

C. Miscellaneous Metal Fabricators are specified elsewhere in Division 5.

SECTION MISCELLANEOUS METALS

603 Summit Avenue, Suite 102 Greensboro, N.C Voice/FAX (336)

Expansion Joint Covers

SECTION STAINLESS STEEL FLEXIBLE CABLE MESH. Show hidden Specifier Notes for best results

PRESTON HEALTH SERVICES ARCHITECT'S NO MITCHELL-HOLLINGSWORTH NURSING & REHAB ADPH #B

SECTION ARCHITECTURAL ORNAMENTAL HANDRAILS AND RAILINGS Summit tm Modular Railing System

A. ASTM A 36 - Standard Specification for Carbon Structural Steel.

SECTION SECTIONAL OVERHEAD DOORS

SECTION WATERTIGHT DOORS. A. Horizontal Sliding Flood Barrier with frame and hardware.

SPECIFICATIONS SECTION FLOOD CONTROL GATES. A. ASTM C 39 - Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens.

Trex Commercial Products page Decorative Metal Railing

SECTION DECORATIVE METAL FENCES AND GATES

SECTION ARCHITECTURAL ORNAMENTAL HANDRAILS AND RAILINGS Monaco tm Modular Railing System

SEISMIC RESTRAINT SYSTEM

SERIES STB30 STEEL FIXED THERMAL BREAK DETENTION WINDOWS SECTION 08651

SECTION COLD-FORMED METAL FRAMING

1. Cast-in-place concrete is specified in Section

SECTION MANUAL FOUR FOLD DOORS MODEL 38 DECORATIVE PANEL DESIGN

SECTION A. Manufacturer's data sheets on each product to be used, including:

SECTION RADIATION SHIELDING ENCLOSURE Low Intensity Radiation Protection

.1 American Institute of Steel Construction (AISC) Specifications for Steel Buildings AISC

Expansion Joint Covers (079513)

1. Temperature Change: 120 deg F (67 deg C), ambient; 180 deg F (100 deg C), material surfaces.

Student Services & Classroom Addition SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

Union County Vocational - Technical Schools Scotch Plains, New Jersey

SECTION RADIO FREQUENCY SHIELDING ENCLOSURE RF Welded System

SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

SECTION HANDRAILS AND RAILINGS. Display hidden notes to specifier. (Don't know how? Click Here)

SECTION COLD-FORMED METAL FRAMING

SECTION CRL70 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

SECTION ARCHITECTURAL GLASS HANDRAIL AND RAILINGS 3-Line Glass Rail Railing Spec

Transcription:

SECTION 112423 SUSPENDED MAINTENANCE ANCHORAGE SYSTEM PART 1 GENERAL 1.1 SECTION INCLUDES A. Suspended Access Anchorage Systems: 1. System design and certification. 2. Fall protection roof anchors. 3. Rigging sleeves. 4. Davits. B. Personal Fall Arrest Anchorage Systems: 1. System design and certification. 2. Fall protection roof anchors. 3. Horizontal lifelines. 4. Training. 1.2 RELATED SECTIONS A. Section 03300 - Cast-In-Place Concrete. B. Section 05120 - Structural Steel. C. Section 05500 - Metal Fabrications. D. Section 07500 - Membrane Roofing. E. Section 07700 - Roof Specialties and Accessories. 1.3 REFERENCES A. Occupational Safety and Health Administration (OSHA): 1. OSHA 1910, Subpart D - Walking and Working Surfaces. 2. OSHA 1910.66, Subpart F - Powered Platforms. 3. OSHA 1910.66, Appendix C - Personal Fall Arrest Systems. 4. OSHA Procedures and Precautions for Employees Using Decent Control Equipment. B. International Window Cleaning Association: ANSI/IWCA I-14.1 - Window Cleaning Safety Standard. C. American National Standards Institute: ANSI Z 359 - Fall Protection Code. D. American Institute of Steel Construction (AISC): Load and Resistance Factor Design. E. ASTM International: 1. ASTM A 36 - Standard Specification for Carbon Structural Steel. 2. ASTM A 276 - Standard Specification for Stainless Steel Bars and Shapes. 3. ASTM A 492 - Standard Specification for Stainless Steel Rope Wire. 11014-1

4. ASTM A 500 - Standard Specification for Cold Formed Welded and Seamless Carbon Steel Structural Tubing in Rounds and Shapes. 5. ASTM A 572 - Standard Specification for High-Strength Low-Alloy Columbium-Vanadium Structural Steel. F. American Welding Society: AWS D1.1 - Structural Welding Code. 1.4 SUBMITTALS A. Submit under provisions of Section 01300. B. Product Data: Manufacturer's data sheets and detail drawings for each product to be used, including: 1. Preparation instructions and recommendations. 2. Storage and handling requirements and recommendations. 3. Product literature, material specifications. 4. Installation details and methods. 5. Dimensions of product components. 6. Finishes of anchor components. C. Shop Drawings 1. Shall be to scale and clearly show dimensioned layout of system components. 2. Include details for each specified product to indicate materials, dimensions, accessories, rated load, and ultimate load. Details shall clearly indicate attachment to building structure and welds shall be indicated by AWS welding symbols, distinguishing between shop and field welds, and show size, length and type of each weld. 3. Include notes to indicate proper use of system 4. Shall bear the seal of the supervising registered professional engineer. Professional engineer shall be licensed in the jurisdiction where the project is located. D. Close-out Submittals: 1. Provide a Fall Protection Anchorage System Log Book to include: a. Requirements for inspection and re-certifications. b. Statement by supervising registered professional engineer that system was designed and installed in compliance with current OSHA, ANSI, and state regulatory requirements and is certified for use. c. As-built Drawings to indicate as-installed anchorage locations, details, and user notes. d. Manufacturer's 1 year standard warranty document commencing on date of project substantial completion. Manufacturer's warranty is in addition to any warranties as required by project contract documents. 1.5 QUALITY ASSURANCE A. Manufacturer Qualifications: 1. Provide products for a manufacturer that specializes in the design, fabrication, and installation of fall protection anchorage systems with a minimum of ten years of documented experience. Companies such as miscellaneous steel fabricators that do not normal design and fabricate fall protection anchorage components are not acceptable. 2. Manufacturer shall carry specific liability insurance (products and completed operations) in an amount not less than $5,000,000 to protect against product failure. 3. Manufacturer shall provide samples of product for inspection or outside agency testing at the request of the owner. Manufacturer shall be 11014-2

compensated for additional product. B. Installer Qualifications: 1. Installation contractor shall be trained or qualified by manufacturer. 2. The fall protection install contractor shall maintain appropriate insurances as applicable for the installation of fall protection systems. Installer shall have specific liability insurance (products and completed operations) in an amount not less than $5,000,000. Proof of these insurance listings shall be supplied with the submittals listed in herein. 3. Welding methods shall comply with AWS D1.1 and welding personnel shall be certified in accordance with AWS requirements. 1.6 DELIVERY, STORAGE, AND HANDLING A. Deliver, store and handle materials and products in strict compliance with manufacturer's instructions and recommendations and industry standards. B. Inspect products prior to installation and replace damage products. C. Store products indoors in manufacturer's or fabricator's original containers and packaging, with labels clearly identifying product name and manufacturer. Protect from damage. 1.7 SEQUENCING AND COORDINATION A. Coordinate installation of products that connect to the work of other trades. Furnish setting drawings and directions for installing products that are to be embedded in concrete or masonry. Deliver such items to the project site in time for installation. B. General Contractor shall be immediately made aware of any site conditions that may interfere with proper installation and intended use of anchorage system. 1.8 PROJECT CONDITIONS A. Maintain environmental conditions (temperature, humidity, and ventilation) within limits recommended by manufacturer for optimum results. Do not install systems under environmental conditions outside manufacturer's recommended limits. PART 2 PRODUCTS 2.1 MANUFACTURERS A. Acceptable Manufacturer: Peak Fall Protection, Inc., which is located at: 817 Center St. P. O. Box 965 ; Apex, NC 27502; Toll Free Tel: 866-387-9965; Tel: 919=387-9965; Fax: 919-387-9914; Email: info@peak-fp.com Web: www.peak-fp.com B. Substitutions: Not permitted. 2.2 SYSTEM DESCRIPTION A. System Design Requirements: 1. Fall Protection Anchorage Systems: Complies with current OSHA, ANSI, and applicable state regulatory requirements. 2. Suspended Access Anchorage Systems: Provide independent anchorages for fall arrest in addition to anchorages used for suspension or equipment tieback. 3. Suspended Access Anchorage Locations: Coincide with areas of the buildings' facade needing to be serviced. Consideration shall be given for the 11014-3

type of service required and service methods. 4. Personal Fall Arrest Anchorage Systems: Provide rooftop edge access to designated roof areas where parapet height does not meet OSHA/ANSI requirements for fall prevention. Refer to building drawings for extent of fall protection system. B. Fall Protection Anchorage Design Requirements: 1. Fall Protection Roof Anchors: Capable of sustaining a minimum ultimate load of 5000 lbs (2268 kg) in any direction the load may be applied without fracture or failure. 2. Fall Protection Roof Anchors: Capable of sustaining a minimum proof load of 2500 lbs (1134 kg) in any direction the load may be applied without damage or permanent deformation. 3. Fall Protection Roof Anchors: Designed with a minimum working load of 1250 lbs (567 kg) in any direction the load may be applied. C. Davit and Rigging Sleeve Design Requirements: 1. Davits and Rigging Sleeves: Capable of supporting an ultimate load of not less than 4 times the rated load. Rated load shall be 1,000 lbs (453 kg) minimum. 2. Outreach of portable davit boom shall not exceed 8 ft 6 inches (2590 mm). Portable davit mast shall be capable of 360 degree rotation. D. Horizontal Lifeline Design Requirements: 1. The horizontal lifeline shall be designed for a minimum of two (enter 1-3 as required) users, each using an energy absorbing lanyard which limits the force applied to the horizontal lifeline to 900 lbs (or as designated by the Qualified Fall Protection Engineer, not to exceed 1,800 lbs). 2. Horizontal lifelines designed for multiple users shall be analyzed using lumped mass or sequential fall calculations. 3. Termination anchors, intermediate anchors, and cable components shall maintain a minimum safety factor of 2:1 as required by OSHA, specifically 1926.502(d)(8). 4. Permanently installed horizontal lifelines shall be designed for fall arrest in accordance with ANSI Z359.6 section 6.2.2.2. 5. Horizontal lifeline required clearance shall be less than or equal to the available clearance for the system. Clearance safety margin shall comply with ANSI Z359.6. E. Monorail System: 1. Capable of supporting an ultimate load of not less than 4 times the rated load for the combination of both an equipment line and safety line. Rated vertical service load shall be 1,250 lbs (567 kg). 2.3 MATERIALS A. Steel: Minimum strengths. 1. Structural Steel W-Shapes: ÅSTM A 572, Grade 50, Fy= 50 ksi. 2. HSS (Tube): ÅSTM A 500, Grade B, Fy = 46 ksi. 3. Angles, Channels, and Plates: ASTM A 36, Fy = 36 ksi. 4. Stainless Steel Shapes: ASTM A 276, Type 304. 5. Stainless Steel Wire Rope: ÅSTM A 492, Type 316, 5/16 inch (8 mm) minimum diameter. B. Aluminum: 6061-T6 alloy. C. Fasteners: Provide stainless steel Type 304 for exterior fasteners exposed to 11014-4

weather. Diameter of bolt sizes per designer/engineer. D. Non Stainless Steel Materials: Hot dipped galvanized. 2.4 MANUFACTURED UNITS A. Fall Protection Roof Anchors: 1. U-Bars: Minimum 0.75 inch (19 mm) diameter type 304 stainless steel with 1.5 inch (39 mm) eye opening. 2. Anchor Posts: Hot dipped galvanized HSS with minimum height as designated by General Contractor to provide not less than 8 inches (203 mm) above finished roof or as necessary to allow proper flashing per roof manufacturer requirements. 3. Baseplates: Minimum 5/8 inch (8 mm) or as designed by manufacturer. Hot dipped galvanized. 4. Fasteners: As designed and provided by manufacturer for proper attachment to substrate. Exposed fasteners are to be Type 304 SS. 5. Adhesive Roof Anchors: Series No. RA-1000. 6. Cast In Place Anchors, 1 Stud: Series No. RA-2100. 7. Cast In Place Anchors, 4 Stud: Series No. RA-2400. 8. Bolt Through Roof Anchors: Series No. RA-4000. 9. Weldable Roof Anchors with Base Plate: Series No. RA-3100. 10. Weldable Roof Anchors: Series No. RA-3400 11. Beam Wrap Roof Anchors: Series No. RA-4700 12. Joist Wrap Roof Anchors: Series No. RA-4500 JW. 13. Adhesive Wall Anchors: Series No. WA-1001. 14. Weldable Wall Anchors: Series No. WA-3001. 15. Bolt Through Wall Anchors: Series No. WA-4001. 16. Column Wrap Anchors: Series No. CW-4104 B. Davits: 1. Portable Davit Arms: a. Composed of extruded aluminum sections with dimensions to suit requirements for height and reach. b. Equipped with (2) adjustable rigging points to allow variation in arm reach. c. All locking pins and hardware to be stainless steel. d. Locking pins to be secured with wire rope lanyards. e. Equipped with carrying handles. f. Shall have a load rating plate stating rated load, manufacturer's contact information, serial number, date of fabrication, and other pertinent information. g. Quantities: As scheduled, indicated on Drawings and required for complete, compliant application. 2. Portable Davit Socket: a. Designed to receive davit arm and for hinged attachment to davit base. b. Equipped with two stainless steel locking pins with fastening tethers and safety pins to prevent unintentional disengagement. 3. Permanently Installed Davit Bases: a. Hot dipped galvanized HSS with minimum height as designated by General Contractor to provide not less than 8 inches (203 mm) above finished roof or as necessary to allow proper flashing per roof manufacturer requirements. b. Designed to prevent accumulation of water. C. Rigging Sleeves: 1. Type: Horizontal. 11014-5

2. Type: Vertical. 3. Portable Boom Assemblies: a. Hot Dipped Galvanized HSS with length and size to suit application. b. Equipped with stainless steel U-bar or stainless steel trolley for attachment of suspension line. c. Shall have a load rating plate stating rated load, manufacturer's contact information, serial number, date of fabrication, and other pertinent information. d. Quantities: As scheduled, indicated on Drawings and required for complete, compliant application. 4. Permanently Installed Rigging Sleeve Bases: a. Hot dipped galvanized HSS with minimum height as designated by General Contractor to provide not less than 8 inches (203 mm) above finished roof or as necessary to allow proper flashing per roof manufacturer requirements. b. Designed to prevent accumulation of water. D. Intermittent Stabilization Buttons: 1. Material: Stainless Steel 2. Locate receptacles every third floor or 50ft, whichever is less, and in line with platform suspension points. 3. Include sufficient quantity of stainless steel stabilizer ties. 4. Designed with a minimum safety factor of 4:1 and a minimum of 600 lbs against fracture or detachment. E. Horizontal Lifelines: 1. Horizontal Lifeline system shall be composed of galvanized steel fall protection anchors and stainless steel wire rope. Extent of system is as noted on contract Drawings. 2. Wire rope shall be minimum 5/16 inch (8 mm) diameter. Wire rope and wire rope termination components shall be stainless steel. 3. Shall allow user to bypass intermediate anchors without detachment or reattachment to the system. 4. Provide two (enter 1-3 as required) stainless steel cable runner devices capable of attachment and removal at any point along the system. F. Personal User Equipment 1. OSHA/ANSI Z359 Compliant Full Body Harnesses. QTY = 2 Units 2. Enter Project Specific Lanyard/SRL information as Required. G. Monorail Systems 1. Material: Extruded Aluminum with Mill Finish. 2. Extent of system is as noted on contract drawings. 3. Shall have a load rating plate stating rated load, manufacturer's contact information, serial number, date of fabrication, and other pertinent information. 4. Include four (enter QTY as required) stainless steel trolleys. 5. Include end stops at locations as require to prevent trolley disengagement. 6. Provide galvanized steel support brackets at locations as required to provide for proper load rating and proper support at monorail joints. 2.5 FABRlCATlON A. Product manufacturing shall be constructed without defects in appearance or defects damaging to the performance of the product. B. Anchors shall be checked for any material (including but not limited to welding 11014-6

PART 3 EXECUTION material build-ups) and are free of sharp edges or abrasions that can cause damage to workers ropes. 3.1 EXAMINATION AND PREPARATION A. Inspect and prepare substrates for compliance with anchorage requirements using the methods recommended by the manufacturer for achieving best result for the substrates under project conditions. B. Do not proceed with installation until substrates have been prepared using the methods recommended by the manufacturer and deviations from manufacturer's recommended tolerances and conditions that will be detrimental to the anchorage system are corrected. Commencement of installation constitutes acceptance of conditions. C. If preparation is the responsibility of another installer, notify Architect in writing of deviations from manufacturer's recommended installation tolerances and conditions. 3.2 INSTALLATION A. Install products in accordance to manufacturer's instructions and approved shop drawings. B. Coordinate installation with General Contractor to ensure an approved water-tight roofing and flashing method will be used. C. Clean mounting surfaces to insure direct and even bearing of base plates. D. Torque fasteners to manufacturer's required rating. E. All fasteners threads shall be deformed by mechanical, chemical or welding methods to prevent accidental removal or vandalism. F. All welders must be certified to applicable American Welding Society (AWS) standards. G. After installation, clean and paint as necessary any field welds with cold galvanizing compound to prevent corrosion. 3.3 FIELD QUALITY CONTROL A. Anchors utilizing adhesive studs shall be tested using a load cell test apparatus in accordance with manufacturer's written instructions. B. Equipment shall be tested and inspected on site in accordance with manufacturer's recommendations and under the supervision of a professional engineer. Testing should be conducted in accordance with applicable OSHA/ANSI standards. Testing data shall be recorded and submitted with system log book. 3.4 PROTECTION A. Protect installed products until completion of project. B. Touch-up, repair or replace damaged products before Substantial Completion. 3.5 ADJUSTMENT 11014-7

A. Verify that products have been installed in accordance with manufacturer's instructions. Adjust as necessary to ensure compliance. B. Correct component deficiencies to assure compliance prior to substantial completion. 3.6 TRAINING A. Provide on-site instruction by manufacturer's certified technician for owner's designated operators in proper use of personal fall arrest anchorage system. Provide at least one 2 hr training session and one bound copy of training materials. END OF SECTION 11014-8