DIVISION [11014] SUSPENDED MAINTENANCE AND FALL PROTECTION EQUIPMENT

Similar documents
SECTION SUSPENDED MAINTENANCE ANCHORAGE SYSTEM

SECTION STRUCTURE MOUNT RAILING SYSTEM

DBI-SALA Uni 8 Horizontal Lifeline Cable System

1. Temperature Change: 120 deg F (67 deg C), ambient; 180 deg F (100 deg C), material surfaces.

DBI-SALA Uni 8 Overhead Horizontal Lifeline Cable System SECTION HORIZONTAL FALL PROTECTION - OVERHEAD CABLE

SECTION LATCHWAYS CONSTANT FORCE POSTS

SECTION COLD-FORMED METAL TRUSSES

A. ANSI A10.32, "Personal Fall Protection Used in Construction and Demolition Operations."

1. Base plates, setting plates and anchor rods for columns. 8. Lintels if connected to structural steel columns.

SECTION HORIZONTAL FALL PROTECTION RAIL

SECTION STRUCTURAL STEEL FRAMING

SECTION SUSPENDED ACCESS SUPPORT EQUIPMENT AND FALL RESTRAINT EQUIPMENT

SECTION FABRICATED ENGINEERED STRUCTURES. A. Pre-engineered, shop-fabricated structural steel building with formed purlin framing.

STRUCTURAL STEEL FRAMING

K. ASTM F436- Standard Specification for Hardened Steel Washers; 2011.

C. Miscellaneous Metal Fabricators are specified elsewhere in Division 5.

PRESTON HEALTH SERVICES ARCHITECT'S NO MITCHELL-HOLLINGSWORTH NURSING & REHAB ADPH #B

DIVISION 5 - STRUCTURAL STEEL AND IRON WORK

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

SECTION METAL STAIRS

SECTION STRUCTURAL METAL FRAMING

SECTION MISCELLANEOUS METALS

SECTION STEEL JOIST FRAMING

.1 American Institute of Steel Construction (AISC) Specifications for Steel Buildings AISC

A. American Society for Testing and Materials (ASTM):

DIVISION 5 METALS SECTION STRUCTURAL STEEL

TCC/SHORE TRANSIT BUS MAINTENANCE FACILITY - PHASE II

SECTION METAL STAIRS

A. Structural Steel: Elements of structural-steel frame, as classified by AISC 303, "Code of Standard Practice for Steel Buildings and Bridges.

SECTION METAL FABRICATIONS

SECTION ORNAMENTAL ALUMINUM RAILING

SECTION WELDED STEEL PICKET FENCE. 1. Fusion welded and rackable ornamental steel picket fence system.

SECTION 2 DIVISION 05 METALS

SECTION METAL FABRICATIONS FOR STEAM UTILITY DISTRIBUTION

Northpointe Renovation EPN #1701 F/A Project #17027 September 8, 2017

SECTION STRUCTURAL STEEL

SECTION HANGERS AND SUPPORTS FOR ELECTRICAL SYSTEMS

Student Services & Classroom Addition

Facility Repairs - MCAS Cherry Point - Tank Farm A SECTION STRUCTURAL STEEL 05/14

SECTION HANDRAILS AND RAILINGS. A. Section Metal Fabrications: Associated metal supports.

SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

SECTION STRUCTURAL STEEL

Insulating Cellular Concrete Steel Joists Painting. A. America Society for Testing and Materials (ASTM):

SECTION (16071) - VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

Project Address: Name of Person Completing Form:

SECTION ORCHESTRA PIT FILLER

SECTION RADIO FREQUENCY SHIELDING ENCLOSURE RF Welded System

SECTION [ ] COILING COUNTER DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

SECTION PORTABLE RAILING SYSTEM

SECTION RADIO FREQUENCY SHIELDING ENCLOSURE RF Modular Galvanized System

C. OSHPD: Office of Statewide Health Planning and Development for the State of California.

SUNY GENESEO RED JACKET DINING HALL RENOVATION SECTION STRUCTURAL STEEL FRAMING

SECTION ORNAMENTAL ALUMINUM RAILING

SECTION ORNAMENTAL WELDED STEEL FENCING

B. Shop Drawings: Include plans, elevations, sections, details, and attachments to other work.

SECTION HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT

Division MEDICAL EQUIPMENT SUPPORT SYSTEMS PART 1 GENERAL

SECTION VIBRATION AND SEISMIC CONTROLS FOR HVAC PIPING AND EQUIPMENT

SECTION METAL WALL PANEL SYSTEM

STRUCTURAL STEEL FRAMING Section

METAL LADDERS (LADDER SAFETY GATE FALL PROTECTION)

GUIDE SPECIFICATIONS CURA ADJUSTABLE REROOF FRAMING SYSTEMS SECTION REROOFING ADJUSTABLE FRAMING SYSTEM

Student Services & Classroom Addition SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

B. Shop Drawings: Include plans, elevations, sections, details, and attachments.

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

Daytona Beach Pier Building Renovation Jun 2010

NORTH HARRIS COUNTY REGIONAL WATER AUTHORITY PIPE HANGERS, Section PIPE HANGERS, SUPPORTS, AND RESTRAINTS

American Metal Specialties, Inc.

SECTION ORNAMENTAL ALUMINUM FENCING

A. Section Metal Decking. (05300 in MF95) B. Section Cold Formed Metal Framing. (05400 in MF95)

Statement of Special Inspections

SHORING & UNDERPINNING 02250

SECTION HANGERS AND SUPPORTS FOR PLUMBING PIPING AND EQUIPMENT

SECTION STAINLESS STEEL WALL PANELS

University of New Hampshire Scholars' Repository

SECTION (05300) - STEEL DECKING

A. Section includes conventionally glazed aluminum curtain walls installed as stick assemblies.

SECTION PIPE AND TUBE RAILINGS

SECTION METAL DECKING. A. Extent of metal decking is indicated on Plans, including basic layout for the following type of deck required:

UNISTRUT CORPORATION GENERAL NOTES 1. THIS UNISTRUT SUPPORT SYSTEM IS DESIGNED TO SUPPORT A MAXIMUM UNIFORM LOAD OF PSF.

Statement of Special Inspections Michigan Building Code 2012 (MBC 2012)

SECTION COLD-FORMED METAL FRAMING

Superior Aluminum Guide Specification 10/4/2016 Non-Welded Aluminum Pipe Railing

Phenolic Exterior Wall Cladding

SECTION Temperature Change: 120 deg F, ambient; 180 deg F, material surfaces.

2016 CDM Smith All Rights Reserved July 2016 SECTION STEEL ROOF DECK

SECTION STRUCTURAL STEEL FRAMING

SECTION COLD-FORMED METAL FRAMING

SECTION VIBRATION CONTROLS FOR PLUMBING PIPING AND EQUIPMENT

SECTION STRUCTURAL STEEL FRAMING

Product Guide Specification DIVISION SPECIALTIES MANUFACTURERS OF PROTECTIVE COVERS

SECTION PIPE AND TUBE RAILINGS PART 1- GENERAL 1.1 RELATED DOCUMENTS 1.2 SUMMARY 1.3 PERFORMANCE REQUIREMENTS

Addendum #4 NEW LOW HEAD OXYGEN SYSTEM Contractor EXHIBIT T SPECIAL PROVISIONS SECTION METAL SHADE STRUCTURE

Mezzanines By Design Page 1

Keuka Studios May 2008 SECTION {05720} CABLE RAILING SYSTEM {CABLE RAILING SYSTEM} Display hidden text for Specifier Notes.

SECTION (10705) EXTERIOR SUN CONTROL DEVICES

SECTION INDUSTRIAL ACCESS / INSPECTION HATCH. A. Industrial Access / Inspection Hatch: Model AH-710

Commission No Section

SECTION STEEL DECKING

SPECIAL INSPECTION AGREEMENT

Transcription:

DIVISION [11014] SUSPENDED MAINTENANCE AND FALL PROTECTION EQUIPMENT 1 GENERAL 1.01 SUMMARY A. Section includes delegated design and supply of suspended maintenance and fall protection equipment. 1.02 Comply with the general and specific conditions of the contract, specifications, and drawings. 1.03 RELATED SECTIONS: Remove sections that do not apply to the project, and update to match remainder of specification. A. Submittal Procedures Section [01330] B. Concrete Forms and Accessories Section [03100] C. Cast In-place Concrete Section [03300] D. Post Tensioned Concrete Section [03380] E. Pre-cast Concrete Section [03400] F. Masonry Assemblies Section [04800] G. Structural Metal Framing Section [05100] H. Metal Joists Section [05200] I. Metal Deck Section [05300] J. Cold-Formed Metal Framing Section [05400] K. Metal Fabrications Section [05500] L. Rough Carpentry Section [06100] M. Damproofing and Waterproofing Section [07100] N. Thermal Protection Section [07200] O. Membrane Roofing Section [07500] P. Flashing and Sheet Metal Section [07600] Q. Roof Specialties and Accessories Section [07700] R. Building Service Piping Section [15100] Specify water supply with standard hose bib connections at roof level(s). S. Electrical Power Section [16200] Specify convenience and hoist electrical supply at roof level with strain relief anchors in accordance to IWCA recommendations. 1.04 REFERENCED STANDARDS Division [11014] Suspended Maintenance and Fall Protection Equipment Page 1 of 7

A. Occupational Safety and Health Administration (OSHA): 1. OSHA 1910, Subpart D Walking and Working Surfaces 2. OSHA 1910.66, Subpart F Powered Platforms 3. OSHA 1910.6, Appendix C Personal Fall Arrest Systems 4. OSHA 1926, Subpart M Fall Protection B. [Minnesota OSHA] 1. [Minnesota Rules, Parts 5205.0650 to 5205.0730] C. [California OSHA] 1. [Division 1. Department of Industrial Relations, Subchapter 4. Construction Safety Orders] 2. [Division 1. Department of Industrial Relations, Subchapter 7. General Industry Safety Orders, Group 1. General Physical Conditions and Structures, Article 5. Window Cleaning] Specify additional State, Local, Contractual, or other referenced standards as necessary. D. American National Standards Institute (ANSI) / International Window Cleaning Association (IWCA) ANSI/ IWCA I-14.1 Window Cleaning Safety Standard. E. ANSI Z359 Safety Requirements for Fall Arrest Systems, Subsystems, and Components F. American Society of Mechanical Engineers (ASME) ASME A120.1, Safety Requirements for Powered Platforms for Building Maintenance G. American Institute of Steel Construction (AISC) Steel Construction Manual [14th Edition] H. American Welding Society (AWS) 1. AWS D1.1 Structural Welding Code Steel 2. AWS D1.2 Structural Welding Code Aluminum 3. AWS D1.6 Structural Welding Code Stainless Steel I. American Society for Testing and Materials (ASTM) 1. ASTM A36 Standard Specification for Carbon Structural Steel 2. ASTM A276 Standard Specification for Stainless Steel Bars and Shapes 3. ASTM A304 Standard Specification for Carbon and Alloy Steel Bars Subject to End-Quench Hardenability Requirements 4. ASTM A500 Standard Specification for Cold Formed Welded and Seamless Carbon Steel Structural Tubing in Rounds and Shapes 5. ASTM A572 Standard Specification for High-Strength Low-Alloy Columbian-Vanadium Structural Steel Division [11014] Suspended Maintenance and Fall Protection Equipment Page 2 of 7

J. Aluminum Association, Aluminum Design Manual, Specifications & Guidelines for Aluminum Structures K. ASTM A153 Standard Specification for Zinc Coating (Hot Dip) on Iron and Steel 1.05 ADMINISTRATIVE REQUIREMENTS A. Coordination: 1. Coordinate selection of roofing materials adjacent to anchorages. The roofing warrantee shall be maintained. Flexible boots are required at roofing penetrations to allow for temporary deflection during testing and use. 2. [Coordinate topcoat finishes applied over materials supplied under this specification section. Comply with paint and coating manufacturer s written recommendations for compatibility.] 1.06 PRECONSTRUCTION SUBMITTALS A. Product Data: 1. Roof anchor manufacturer data sheet(s) 2. Fastener manufacturer data sheet(s) B. Installer qualifications listing the names of three similar completed projects. C. [Field Welding Qualifications for personnel per AWS D1.1 for structural steel,] [D1.2 for aluminum,] [and D1.6 for stainless steel] D. Shop Drawings: Include roof plans with maintenance drop locations showing routing of temporary equipment supplied by the maintenance contractor such as ropes and counterweight beams, elevations indicating intermittent stabilization anchors, sections at each attachment to the primary structural system, details of each fastener, and including applicable information of adjacent supporting structure. E. Delegated Design: Include analytical structural calculations of the connection and the supporting structure s capacity including service / fatigue design, testing, and ultimate / failure load combinations for each type of anchorage. F. Certification Letter: Include a letter certified by an engineer registered in the project s state noting that the primary structural system has adequate capacity to support the transient equipment loading when combined with the applicable dead and live loads. G. Manufacturer Insurance Certificate(s) including product liability specifically for suspended maintenance and fall protection equipment. H. Installer Insurance Certificate(s) including workmen s compensation, comprehensive general liability, and comprehensive automobile liability. 1.07 CLOSEOUT SUBMITTALS A. Manufacturer s Warrantee on parts for a term of 1 year on finish and structural capacity. Division [11014] Suspended Maintenance and Fall Protection Equipment Page 3 of 7

B. Log Book including record shop drawings indicating the constructed condition with a completed initial testing log, yearly inspection log to be filled out by others, a 10-year retest log to be filled out by others, and an appendix containing the Preconstruction Submittals. 1. Log book shall include the statement: Systems users to inspect all equipment prior to each use, including all visible attachment points, locks, and pins to ensure all equipment is in safe working order. All users shall be trained on proper use of the equipment, as well as knowing and complying with OSHA, ANSI, and other pertinent life safety regulations. All equipment shall be annually inspected by a qualified person and also re-certified within 10 years under direct supervision of a licensed engineer. C. [Operating Procedures Outline System (OPOS) per California Code of Regulations, Title 8, Article 5, Appendix A.] OPOS is required for projects within the State of California D. Laminated placards noting the log book location and showing the system layout for each permanent roof access location. 2 PRODUCTS 2.01 MANUFACTURER(S) A. Engineered Supply, LLC 1. Address: 1286 Oldridge Avenue North, Stillwater, MN 55082 2. Phone: 612.508.6727 3. Email: info@engineeredsupply.com 4. Web: www.engineeredsupply.com Specify additional manufacturers as necessary. Consider Probel (www.pro-bel.ca) and Tractel (www.tractel.com) if additional manufacturers are required. B. Substitutions: [Substitutions will not be permitted] [Substitutions will be considered in accordance with provisions of Division 1 of this specification] 2.02 SYSTEM DESIGN REQUIREMENTS A. Design and anchorage layout to comply with OSHA, ANSI, IWCA, applicable state regulatory requirements, and other project requirements as necessary. B. Provide graphical design indicating areas of the building to be serviced. Provide complete coverage for the type of service required and service methods. Remove sections that do not apply C. Fall Protection Anchorages 1. Capable of sustaining a minimum ultimate load of 5,000 pound force in any direction the load may be applied for fall arrest. Division [11014] Suspended Maintenance and Fall Protection Equipment Page 4 of 7

D. Suspended Maintenance and Tieback Anchorages, Rigging Sleeves, Monorails, and Davits 1. Capable of sustaining a 1,250 pound force service load in any direction the load may be applied under allowable stresses for material fatigue loading. 2. Capable of sustaining a 1,800 pound force impact service load in any direction the load may be applied for fall arrest loading. 3. Capable of sustaining a 2,500 pound [5,000 pound in California] force test load in any direction the load may be applied under the elastic limits of the materials. 4. Capable of sustaining a minimum ultimate load of 5,000 pound force in any direction the load may be applied under the plastic limits of the materials. E. Horizontal Lifelines 1. Capable of sustaining a 1,800 pound force impact service load in any direction the load may be applied when two users are attached to the system with shock absorbing lanyards limiting the force applied to the system to 900 pounds force for each user. 2. Maintain a minimum factor of safety from service loads to elastic material limits of 2:1. 3. Capable of sustaining a minimum ultimate load of 5,000 pound force in any direction the load may be applied under the plastic limits of the materials. 4. All components of the system shall be directly specified and supplied including manufacturer, make, and model in the design. No replacement components or equals are allowed. F. Materials 1. W Shapes to be ASTM A572, Grade 50 2. HSS tube and pipe to be ASTM A500, Grade B 3. Miscellaneous steel shapes to be ASTM A36 4. Stainless steel shapes to be ASTM A276, 304 5. Aluminum to be 6061 or 6063 with an appropriate temper 6. Welding rods and bare electrodes per AWS requirements 7. Galvanizing repair paint to be high zinc dust content paint compatible with surfaces to be coated 8. Provide stainless steel fasteners for all concealed locations. Hot dipped galvanized fasteners are acceptable for exterior visible locations. 2.03 PRODUCT REQUIREMENTS A. Anchors shall be completely free of sharp edges or abrasive surfaces. Division [11014] Suspended Maintenance and Fall Protection Equipment Page 5 of 7

B. Specifically deburr hoops after hot dip galvanizing process. C. All exposed portions of carbon steel anchors shall be hot dipped galvanized or aluminum thermal sprayed. D. Vent holes to accommodate the hot dip galvanizing process shall be permanently sealed. 3 EXECUTION 3.01 INSTALLATION 1. Provide a minimum of 3/4" diameter attachment hoop. Attachment hoop shall be capable of sustaining 5,000 pound force in any direction the load may be applied under the plastic limits of the materials. 2. Inside radius shall be a minimum of 1.625 [2 diameter closed hoop in California]. A. Sequence and coordinate with other ongoing work, allowing appropriate notice to other trades and inspectors. B. Verify substrates match the recommendations of the manufacturer and the project specific shop drawings. Notify the [Engineer of Record] [and Architect of Record] immediately if site conditions vary from the documented conditions. C. Verify bearing surfaces are even, plumb, and true. Uneven bearing surfaces may lead to loosening of anchorages during load testing and rejection of anchorage. D. Install anchors and fasteners in strict accordance to manufacturer requirements. E. Torque fasteners with a calibrated torque wrench in strict accordance to manufacturer requirements. F. Fasteners shall be vibration proof through the use of permanent thread locking compound, deformed thread nuts, or damaged threads. Split ring lock washers are not acceptable without additional retention as noted. G. Coordinate installation with the [Roofing Contractor] [and General Contractor] to verify installation will result in a warrantable building envelope. H. Prevent galvanic action and other forms of corrosion by insulating metals from direct contact with incompatible materials. I. Prepare and touch up blemishes and carbon steel field welds with cold galvanizing compound. 3.02 INSPECTION A. 100% of adhesive anchors shall be tensioned tested to an equivalent of the maximum anchor test load with a calibrated scale or calibrated hydraulic test apparatus. B. Adhesive anchors shall be inspected in accordance with the requirements of the manufacturer. Division [11014] Suspended Maintenance and Fall Protection Equipment Page 6 of 7

C. Equipment shall be initially load tested under the direct supervision of a licensed engineer in accordance with ANSI, OSHA, and IWCA requirements. D. Each anchor shall be inspected for conformance to manufacturer requirements, building envelope, looseness, and signs of permanent deflection during load testing. 3.03 TRAINING A. Provide on-site instruction by manufacturer technician for Owner s representative in proper use, maintenance, and inspection requirements of the system. 3.04 CORRECTION OF DEFICIENT WORK A. Repair or replace non-conforming and damaged products and inspect as necessary to supply a complete, useable system. Division [11014] Suspended Maintenance and Fall Protection Equipment Page 7 of 7