and Shield with Vertical Needle Holder REF 90072

Similar documents
REF DOC # STANDARD IMAGING, INC Murphy Drive Middleton, WI TEL TEL FAX

REF # DOC #80XXX-00. STANDARD IMAGING, INC Deming Way Middleton, WI TEL TEL FAX

Aluminum Bi-Fold Pet Ramp

Cargo Carrier with Ramp 50In.L x 30 1/4In.W.

Cargo Carrier with Ramp 60In.L x 30 1/4In.W.

UNIVERSAL UTILITY TRUCK RACK

6 Closet light. Model Due to continuing improvements, actual product may differ slightly from the product described herein.

VISE MOUNTED. Model 97359

Installation Guide Document No Transaction Windows Copyright 2017 Terra Universal Inc. All rights reserved. Revised October 2017

8 DIAL CALIPER. Model Diagrams within this manual may not be drawn proportionally.

Mobile Drum Carrier. Owner s Manual

Aluminum Bi-Fold Arched Ramps

3601 E. 34th St. Tucson, AZ USA Tel Fax Web:

Heavy-Duty Aluminum Arched Ramps 10,000-Lb. Capacity Per Pair.

Dandy Leveler UDLV-150 & UDLV-500 (New Style)

7 PIECE TUBE FLARING KIT

Dynatronics Parallel Bars

4 rotary milling table

Y SIDE ALUMINUM TRUCK RACK

WARNING. Introduction ! ATTENTION

GF6580BH-1 PATRIOT LIBERTY QUARTER RAILS:

SHCM SHOWER COLUMN INSTALLATION INSTRUCTIONS

User Guide M Rev A 09/15

Models FWB, LWB, MWB and HWB Brakes AIR CHAMP PRODUCTS. User Manual. (i) MTY (81)

Machinery Mover. Owner s Manual

Model T2642E Wall Mount. Television Wall Mount with Tilt Option

PLEASE SAVE THESE INSTRUCTIONS FOR FUTURE USE

55-Gallon Tilting Drum Ring

NetShelter. Four-Post Rack. Installation and Quick-Start Manual

Owner s Manual & Safety Instructions

PORTABLE CHAIR SCALES BEAM and DIGITAL TYPES MODELS 475, 4751, 6475, 6475k and 6475KGEU

This Installation Guide uses the following symbols to indicate important information. Always observe the instructions indicated by these symbols.

QUATRALUX SHOWER ENCLOSURE INSTALLATION INSTRUCTIONS

92831 TEL: (714) FAX:

PalletPal Low Profile Disc Turntable

Rocker Tool Post ASSEMBLY AND OPERATING INSTRUCTIONS

Double-Drum Forklift Gripper

Owner s Manual & Safety Instructions

STAINLESS STEEL PEG BOARDS

QUATRA LUX SHOWER ENCLOSURE INSTALLATION INSTRUCTIONS

INSTALLATION MANUAL SURFACE-MOUNTED HEADWALL

AQUA UNO TUB DOOR INSTALLATION INSTRUCTIONS

Installation Guide Document No Fire-Rated Pass-throughs Copyright 2017 Terra Universal Inc. All rights reserved. Revised Sept.

Pallet Puller. Owner s Manual

66-Bin Wire Shelf Storage Rack

DRYWALL DOLLY 900 LB. CAPACITY

Needle Loading. Seed Sterilization. Shielding. Seed Handling. SeedVac Seed Slider. Seed Sterilization and Sorting Tray Seed Sterilization Pill Box

SAVE THESE INSTRUCTIONS

Stainless steel rolling cabinet

LOAD RAMP 1000 LB. CAPACITY

117-Bin Wire Shelf Storage Rack

WALL SHELVES. Cleaning and Maintenance INSTRUCTION MANUAL

New Advanced Environmental Air Treatment System

Miniglaze/2. Owner & Operator's Manual PORCELAIN STAINING AND GLAZING FURNACE. Model No: Voltage: V 50/60Hz V 50/60Hz

Installation Guide Document No BioSafe Cleanroom Windows Copyright 2017 Terra Universal Inc. All rights reserved. Revised December 2017

General Guidelines. Tools Required. Safety. Deluxe Steel Folding Scooter & Wheelchair Carrier Instructions for Part # SC500-V3

Free-standing rail systems, adjustable. Item no:

Sby SR Instruments, Inc.

New Advanced Environmental Air Treatment System

QUADLUX SHOWER ENCLOSURE INSTALLATION INSTRUCTIONS

DUST FREE ACTIVE Total Home Air Purification

Model PVIV-PROBE-KIT. Electrical Contact Probe. User's Manual

USER'S GUIDE TO OPERATION

CORNERVIEW SHOWER ENCLOSURE INSTALLATION INSTRUCTIONS

BUTTERFLY SHOWER DOOR INSTALLATION INSTRUCTIONS

MODEL 185R Kontrol-Karrier Operator s Manual for Morse Kontrol-Karrier

ALUMINUM CURB RAMP. Model 98037

Global Water Instrumentation, Inc.

Prostate Brachytherapy

LF1600 Stand Assist Assembly and Operation Manual

DMC When Accuracy Counts

QUATRA SHOWER ENCLOSURE INSTALLATION INSTRUCTIONS

executive safe with Override Key Limited Warranty Operation & Installation Guide Read These Instructions Very Carefully! ENGLISH

Shower Column SHCM Installation Guide

Owner s Manual & Safety Instructions

PRISMLUX SHOWER ENCLOSURE INSTALLATION INSTRUCTIONS

General Guidelines. Instructions for Part # WP Safety. It is the user s responsibility to read and follow all instructions.

Pallet Jack 4,400 Lbs Capacity Model #31001

Effective This guide supersedes all previous versions

Thermoelectric Coolers. All Models INSTRUCTION MANUAL. Rev. G 2016 Pentair Equipment Protection P/N

Precision Roller Pinion System Models RPS16, RPS20, RPS25, RPS32, RPS40 LINEAR MOTION CONTROL PRODUCTS FORM NO. L A-1204.

Daniel Orifice Fittings and Meter Tubes

Installation, Operating and Maintenance Instructions Incognito Series Air Curtain

Electrostatic Technology, Inc. A Subsidiary of Nordson Corporation

Thermoelectric Cooler

Installation, Operating & Maintenance Instructions For Tri-Tech Medical Sleep Lab Panel Series

Adjustable Fused Power Supply

Mechanical Post Lift. Owner s Manual

Mobile Hot Food Merchandiser Series. Series: MM Operation Manual

MODEL NUMBER: 1419 SERIES

INSTALLATION GUIDE MODELS DMV2401 / DMV3001 / DMV3601 DMV4801 / DMV6001 / DMV60DS / DMV72DS

Xxxxx Xxxxxx Autoclave Validation Data Logging System

General Guidelines. Tools Required. Steel Folding Scooter & Wheelchair Carrier Instructions for Part # SC400-V2. Safety

Limited Product Warranty

Operator s Manual for Morse Heavy-Duty Kontrol-Karrier with 3-Piece Drum Holder

Drag Chain Conveyor Installation and Operation Manual

To Contact PS DOORS:

GC-X360S-W GC-X360S-B

FLEX SHOWER DOOR INSTALLATION INSTRUCTIONS. For more information on DreamLine TM Shower Doors please visit

Transcription:

WWW..COM and Shield with Vertical Needle Holder REF 90072 STANDARD IMAGING, INC. 7601 Murphy Drive Middleton, WI 53562-2532 TEL 800.261.4446 TEL 608.831.0025 FAX 608.831.2202 Nov / 2006 2006 Standard Imaging, Inc. DOC #80192-05

General Precautions CAUTION: Proper use of this device depends on careful reading of all instructions and labels. CAUTION: Steam Sterilize (autoclave) or ETO sterilize only. Do not gamma ray sterilize. CAUTION: Leaded glass is susceptible to scratches and attack by acids and alkalis (e.g. ammonia-based glass cleaner). Use only water, non-abrasive cleaning agents and soft cloth. WARNING: After steam sterilization, unit will be hot. Allow adequate cooling time before handling. Do not drop or mishandle unit. WARNING: For use with gamma and x- ray emitting LDR radiation sources only. Warnings and Cautions alert users to dangerous conditions that can occur if instructions in the manual are not obeyed. Warnings are conditions that can cause injury to the operator, while Cautions can cause damage to the equipment. Typical Sterilization Procedures CAUTION: Do not use dry heat or chemical sterilization or damage to the parts may result. WARNING: These items are not sterile when shipped to the customer. Before use they must be sterilized using steam or ethylene oxide (ETO). All parts are fabricated from the highest quality aluminum, stainless steel and plastic, and are designed to withstand high temperatures: Steam sterilization (autoclave): Use the normal cycle (250 degrees F or 121 degrees centigrade at 15 psi for 15 to 30 minutes) or the flash cycle (270 degrees F or 132 degrees centigrade at 30 psi for 3 to 12 minutes). Ethylene oxide (ETO) sterilization: Use cycle and aeration times recommended by the manufacturer of the Sterilizer or use those determined at the hospital. Exterior cleaning should be done with a soft brush and a cloth. Gently brush all surfaces to remove dirt and dust. To remove any remaining dirt, use a cloth slightly dampened with a solution of mild detergent and water or a liquid disinfecting agent. 2

Table of Contents PAGE 2 General Precautions 3 General Operation 4 Maintenance 4 Parts and Accessories 5 Features and Specifications 7 Service Policy 7 Customer Responsibility 8 Warranty General Operation 7601 MURPHY DRIVE MIDDLETON, WI 53562-2532 USA WWW.STANDARDIMAGING.COM The Standard Imaging Needle Loading Platform and Shield with Vertical Needle Holder, REF 90072, provides a convenient work station for counting and handling seeds and for loading into needles in a radiation shielded environment. The preloaded needles are already positioned for an autoradiograph to verify and document the loading sequence. Needle Loading Shield Vertical Needle Holder Assembly Before initial use, assemble the square base of the Needle Loading Shield to the angled plate containing the leaded glass. Using the four 1/4-20 x 5/8 screws and hex key wrench provided, secure the base to the angled plate by inserting the screws into the four holes in the base (from the side with the mounted feet), and fasten securely. Attach the stainless steel Needle Loading Platform to the Needle Loading Shield with the two spring plungers mounted on the Needle Loading Platform. Retract the spring plungers by pulling on the knobs, align the plungers with the holes in the edges of the shield, and release the plungers. Check that the plungers have seated in the holes. Two pins on the Vertical Needle Holder attach it to the Needle Loading Platform by insertion into the holes near the back as in Figure 1. Needle Loading Platform Figure 1: Components of the Needle Loading Platform Sterilize the unit following the sterilization equipment manufacturer s, or health care facility s recommendations. Users should validate the chosen sterilization procedures.

General Operation Continued Twenty implant needles can be placed in the Vertical Needle Holder Assembly for loading. Additional Vertical Needle Holder Assemblies can be used for more than 20 needles. When the needles are loaded with seeds and spacers, the Vertical Needle Holder Assembly can be removed from the Needle Loading Platform and placed on an autoradiographic film to prepare an image of the loaded seeds as in figure 2. A typical exposure time is 60-90 seconds. When used in conjunction with the Standard Imaging SeedVac (REF 90091) and Seed Sterilization and Sorting Tray (REF 90085), the Needle Loading Platform and Shield with Vertical Needle Holder provides an integrated system designed for rapid and convenient loading of prostate implant needles. This system minimizes seed handling time, integrates shielding into all operations, and is completely steam or gas sterilizable. Figure 2: Vertical Needle Holder Assembly on film, ready to verify and document loading. Maintenance As is standard practice, it is recommended that the Needle Loading Platform and Shield with Vertical Needle Holder be examined after each use for deterioration. Exterior cleaning of the non-glass surfaces, if needed, can be done with a cloth slightly dampened with a solution of mild detergent and water. To clean the leaded glass, use a soft cloth with warm water, and if needed, a mild detergent. There are no serviceable parts on the Needle Loading Platform and Shield with Vertical Needle Holder. If assistance is desired in the proper disposal of this product (including accessories and components), after its useful life, please return to Standard Imaging. Parts and Accessories REF 90072 80192 90070 50010 72008 11087 Description Needle Loading Platform and Shield with Vertical Needle Holder Instruction Manual Needle Loading Shield Needle Loading Platform Vertical Needle Holder Assembly Leaded Glass, 8 x 10 x 1/4, ~0.6 mm Pb equivalent 4

Features and Specifications Dimensions: Width: Length: Height: Weight: Material: 30.5 cm (12 in) 30.5 cm (12 in) 40.6 cm (16 in) 9.5 kg (21 lbs) Aluminum, Stainless Steel, Leaded Glass Product Standards: Specifications are subject to change without notice. 5

Notes 6

Service Policy Customer Responsibility If service, including recalibration, is required, please contact Standard Imaging s Customer Service department by phone or email prior to shipping the product. Standard Imaging s Customer Service and Technical Service staff will attempt to address the product issue via phone or email. If unable to address the issue, a return material authorization (RMA) number will be issued. With the RMA number, the product can be returned to Standard Imaging. It is the responsibility of the customer to properly package, insure and ship the product, with the RMA number clearly identified on the outside of the package. The customer must immediately file a claim with their carrier for any shipping damage or lost shipments. Return shipping and insurance is to be pre-paid or billed to the customer, and the customer may request a specific shipper. Items found to be out of warranty are subject to a minimum service fee of 1 hour labor (excluding recalibrations) for diagnostic efforts and require a purchase order (PO) before service is performed. With concurrence from customer, the product may be replaced if it is unserviceable or if the required service is cost prohibitive. Products incurring service charges may be held for payment. Standard Imaging does not provide loaner products. See the Standard Imaging Warranty and Customer Responsibility for additional information. Serialization Information Standard Imaging products that are serialized contain coded logic in the serial number which indicates the product, day and year of manufacture, and a sequential unit number for identification: A YY DDD X This product and its components will perform properly and reliably only when operated and maintained in accordance with the instructions contained in this manual and accompanying labels. A defective device should not be used. Parts which may be broken or missing or are clearly worn, distorted or contaminated should be replaced immediately with genuine replacement parts manufactured by or made available from Standard Imaging Inc. CAUTION: Federal law in the U.S.A. and Canadian law restrict the sale, distribution, or use of this product to, by, or on the order of a licensed medical practitioner. The use of this product should be restricted to the supervision of a qualified medical physicist. Measurement of high activity radioactive sources is potentially hazardous and should be performed by qualified personnel. Should repair or replacement of this product become necessary after the warranty period, the customer should seek advice from Standard Imaging Inc. prior to such repair or replacement. If this product is in need of repair, it should not be used until all repairs have been made and the product is functioning properly and ready for use. After repair, the product may need to be calibrated. The owner of this product has sole responsibility for any malfunction resulting from abuse, improper use or maintenance, or repair by anyone other than Standard Imaging Inc. The information in this manual is subject to change without notice. No part of this manual may be copied or reproduced in any form or by any means without prior written consent of Standard Imaging Inc. A YY DDD X Unique product ID Last two digits of the year (e.g. 1999 = 99, 2000 = 00) Day of the year (1< DDD < 365) Unique unit ID Number (1 < X < 9) 7

Warranty Standard Imaging, Inc. sells this product under the warranty herein set forth. The warranty is extended only to the buyer purchasing the product directly from Standard Imaging, Inc. or as a new product from an authorized dealer or distributor of Standard Imaging, Inc. For a period provided in the table below from the date of original delivery to the purchaser or a distributor, this Standard Imaging, Inc. product, provided in the table is warranted against functional defects in design, materials and workmanship, provided it is properly operated under conditions of normal use, and that repairs and replacements are made in accordance herewith. The foregoing warranty shall not apply to normal wear and tear, or if the product has been altered, disassembled or repaired other than by Standard Imaging, Inc. or if the product has been subject to abuse, misuse, negligence or accident. Product Standard Imaging Ionization Chambers Standard Imaging Well Chambers Standard Imaging Electrometers Standard Imaging BeamChecker Products Standard Imaging Software Products All Other Standard Imaging Products Standard Imaging Custom Products Standard Imaging Remanufactured Products Standard Imaging Custom Select Products Consumables Serviced Product Resale Products ADCL Product Calibration (Standard Imaging uses the UW-ADCL for recalibrations required under warranty) Warranty Period 2 years 2 years 2 years 2 years 1 year 1 year 1 year 180 days 90 days 90 days 90 days As defined by the Original Equipment Manufacturer 0-90 days = 100% of ADCL Calibration Costs 91-182 days = 75% of ADCL Calibration Costs 183 365 days = 50% of ADCL Calibration Costs 366 639 days = 25% of ADCL Calibration Costs (days from date of shipment to customer) Standard Imaging s sole and exclusive obligation and the purchaser s sole and exclusive remedy under the above warranties are, at Standard Imaging s option, limited to repairing, replacing free of charge or revising labeling and manual content on, a product: (1) which contains a defect covered by the above warranties; (2) which are reported to Standard Imaging, Inc. not later than seven (7) days after the expiration date of the warranty period in the table; (3) which are returned to Standard Imaging, Inc. promptly after discovery of the defect; and (4) which are found to be defective upon examination by Standard Imaging Inc. Transportation related charges, (including, but not limited to shipping, customs, tariffs, taxes, and brokerage fees) to Standard Imaging are the buyer s responsibility. This warranty extends to every part of the product except consumables (fuses, batteries, or glass breakage). Standard Imaging, Inc. shall not be otherwise liable for any damages, including but not limited to, incidental damages, consequential damages, or special damages. Repaired or replaced products are warranted for the balance of the original warranty period, or at least 90 days. This warranty is in lieu of all other warranties, express or implied, whether statutory or otherwise, including any implied warranty of fitness for a particular purpose. In no event shall Standard Imaging, Inc. be liable for any incidental or consequential damages resulting from the use, misuse or abuse of the product or caused by any defect, failure or malfunction of the product, whether a claim of such damages is based upon the warranty, contract, negligence, or otherwise. This warranty represents the current standard warranty of Standard Imaging, Inc. Please refer to the labeling or instruction manual of your Standard Imaging, Inc. product or the Standard Imaging, Inc. web page for any warranty conditions unique to the product. 8