BGI, INC. WALTHAM, MA 02451

Similar documents
ARA N-FRM Sampler. Operation Manual April 15, 2017

Title: Standard Operating Procedure for Measurement of Particulate Matter in Ambient Air Using the Partisol 2000H

OPERATING MANUAL. Model 900

SKC PMI Samplers. 25-mm pre-oiled disposable porous plastic disc; reduces particle bounce

WBEA Standard Operating Procedure

Method No.: 8.06/2.0/M Effective Date: January 4, 2012 Location: ###

DustCheck DPM-16. Previous Go to PM10-2,5 sampling adding the Wins impactor 9 of 75 Next Go to DustCheck DPM-5. Sequential sampler

Personal Sampling Overview

Sioutas Cascade Impactor

SOP OPERATION OF PARTICULATE MATTER INSTRUMENTS CLARK COUNTY DEPARTMENT OF AIR QUALITY. Monitoring Division PROCEDURE NUMBER 400

Sioutas Cascade Impactor

Title: Operation of ACCU System Particulate Matter sampler in Ambient Air in conjunction with the Tapered Element Oscillating Microbalance (TEOM)

AerosolInstruments. Micro Technologies, Big Ideas. Product Guide. MSP Corporation Rice Creek Parkway, Suite 300

3M Personal Safety Division. 3M TM EVM Series Environmental Monitor. EVM Series. Quick Start Guide

3M Personal Safety Division. 3M TM EVM Series Environmental Monitor. EVM Series. Quick Start Guide

QUICK START GUIDE. EVM Series Environmental Monitor

Section 8 Technician Level Maintenance

FORSYTH COUNTY OFFICE OF ENVIRONMENTAL ASSISTANCE AND PROTECTION

Title: Standard Operating Procedure for the Continuous Measurement of Ambient PM using a Beta Attenuation Monitor

STATE OF CALIFORNIA AIR RESOURCES BOARD AIR MONITORING QUALITY ASSURANCE VOLUME V AUDIT PROCEDURES MANUAL APPENDIX Z

BX-895 REAL TIME MODULE OPERATION MANUAL

Air Pollution Control Division. Technical Services Program

AerosolInstruments. Product Guide. MSP Corporation Rice Creek Parkway, Suite 300. Shoreview, Minnesota 55126, U. S. A.

Air Monitoring Plan for Ground Intrusive Activities at the Various PPG Hexavalent Chromium Sites in New Jersey

Mar Cor Purification. Carbon Block Filtration System. Operation & Maintenance Manual

STATE OF CALIFORNIA AIR RESOURCES BOARD AIR MONITORING QUALITY ASSURANCE VOLUME V AUDIT PROCEDURES FOR AIR QUALITY MONITORING APPENDIX V

Guidelines for QualiTru Line Sampling

Operational Manual. Spectrophotometer Model: SP-830 PLUS. Metertech Inc. Version 1.07

WEATHER MONITORING. Competitive rates available for long term hire. Hire rate Per week Per month

Dekati. SAC-65 Cyclone. Removal of large particles according to EPA 201A Combustion aerosol measurements Isokinetic sampling

Gilian BDX-II Air Sampling Pump Setup and Use

Step by Step Guide An Introduction to Air Sampling Universal Pump

PM 2.5 Monitoring in the U.S.

Rotating Drum Impactors

Audit Report of SIMAT Particle Monitoring Network

Particulate Matter Seminar

Proweld Equipment Owner & Maintenance Manual FIELD 12 TRENCH (Widos 4900)

Model of a Standard Operating Procedure (SOP) for manual gravimetric PM measurements with a Low Volume Sampler

OUR BRANDS. RENT TO BUY: a smarter solution.

AP5K-C Precision AC Double-Pulse Spot Welding Machine User s Manual Shenzhen Will-Best Electronics Co., Ltd

BIOTRAK REAL-TIME VIABLE PARTICLE COUNTER SAMPLE AND COLLECTION EFFICIENCY

Beta Attenuation Mass Monitor

Shur-Shot X-Proof Hydrogen Fluoride Alarm Operations Manual

ENVIRONMENTAL PROTECTION AGENCY APTI 435: Atmospheric Sampling Course. Student Manual

Industrial flue gas probes. Instruction manual

TABLE OF CONTENTS. Vacuum Cleaner. Model No. MC-CG Bagless Canister Red North America

Model No. BWTDWFK-TRIFLO.

DESCRIPTION OF INTENDED SINGLE SOURCE PURCHASE (PUR 7776)

Report on the 39 th Ave Greenway and Open Channel (39 th Ave) PM10 and Metals Ambient Air Study

Dekati Solutions. Emission Measurements

NSP POWDERIZER POWDER PROCESSING TECHNOLOGY: THE STURTEVANT SOLUTION.

Sampling for particulates

Sampling for particulates

CA11 11 Column. Operator s Manual. To Purchase This Item, Visit BMI Gaming LIMITED WARRANTY

Multi-Level VW Piezometer

APPENDIX B. Second Quarter 2010 IML Quality Assurance Audit Report

APPENDIX F. Fourth Quarter 2009 IML Quality Assurance Audit Report

NORDEN SIZE PARTS. Secure production, superior results

TECHNICAL DATA SHEET

Version Certificate: /

Efficacy of Novaerus NV 1050 System against NO 2 and Formaldehyde Gases

Engineered Systems & Designs TURBIDITY METER

Title: Standard Operating Procedure for Ambient Air Sampling Using a Versatile Air Pollution Sampler (VAPS) with Annular Denuder System (ADS)

High Temperature Aging Cell Instruction Manual

Not compatible with the HOBO U-Shuttle. Plot A ± 1 minute per month at 25 C (77 F); see Plot A

ESSENTIAL FOR SURVIVAL

BIOAIRE CASSETTE Impaction Particle Sampler

NADP AMNet Standard Operating Procedure Site Report B - Laboratory: Glassware Change-out/Monthly Maintenance

Experiment # 2 Aerosol and Trace Gas Sampling

Fine particle measuring system

MSHA Course of Instruction Certified Person; Sampling - CPDM

Using the PPM2 Portable Trace Moisture Transmitter

Operation and Maintenance Manual. Joyce/Dayton Metric Screw Jacks

TWIN LASER PARTICLE COUNTER

METHOD 201A - DETERMINATION OF PM EMISSIONS. 1.1 Applicability. This method applies to the in-stack measurement of

Xxxxx Xxxxxx OM-CP-TEMP101A. Temperature Data Logger with 10 year battery life INSTRUCTION SHEET MQS5026/0117

Indoor Air Quality Solutions

METHOD DETERMINATION OF PM EMISSIONS. (Exhaust Gas Recycle Procedure) 1.1 Applicability. This method applies to the in-stack

2 EMSL ANALYTICAL, INC. S I L I C A P O C K E T G U I D E

ST 19 Aluminium Manually Controlled Electric Model

Analytical Methods For Diesel Particulate Matter(DPM)

King Portable Brinell Hardness Tester

IMPROVE STANDARD OPERATING PROCEDURES. SOP 126 Site Selection. Date Last Modified Modified by: 09/12/96 EAR

Report on the Globeville Landing Outfall (GLO) PM10 and Metals Ambient Air Study

PTC1. Paint Test Cell Kit

COLow COHigh COLow/H comp NO NOx NO2 CO2 H2S SO2 CXHY LANCOM 4. Portable Flue Gas Monitoring.

Report on the Globeville Landing Outfall (GLO) PM10 and Metals Ambient Air Study

VARIO XX28 Stainless Steel Time And Temperature Controlled Electric Model

UNLOADING PROCEDURE FOR FRONTIER TECHNOLOGY CORPORATION MODEL SHIPPING PACKAGE WITH WEP PLUG FOR SOURCES IN HOLDERS

Universal Bottle Sampler

Ambient Dust Sampling

COLow COHigh COLow/H 2

VARIO XX28 Stainless Steel Time And Temperature Controlled Electric Model

Instruction Manual HT 24 BM-D2400 Homogenizer

Element B3 LEV Systems

METRIC DRIVELINES & COMPONENTS AFTERMARKET PRODUCT GUIDE METRIC DRIVELINES & COMPONENTS

To whom it may concern, February 21, 2011

PM 2.5 Continuous Monitoring. Program Objectives, History, Requirements, and Flexibility. National Ambient Air Monitoring Conference Atlanta 2014

Report on the Globeville Landing Outfall (GLO) PM10 and Metals Ambient Air Study

Transcription:

BGI, INC. WALTHAM, MA 02451 MARCH 2001 58 Guinan Street Waltham, MA 02451 Tel: 781-891-9380 Fax: 781-891-8151 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - SHARP CUT CYCLONE INSTRUCTIONS FOR USE AND MAINTENANCE 1.0 Introduction The Sharp Cut Cyclone (SCC) is designed to replace the US EPA WINS Impactor for PM2.5 sampling. It is a non-designated device which has proven advantages over the WINS insofar as it is a dry system and requires cleaning at infrequent intervals (1), (2). Inasmuch as speciation sampling, for particulates, is not governed by an EPA FRM, the SCC may be freely utilized. BGI manufactures two versions of the SCC. They are the SCC-A, which is a direct replacement for the standards WINS. The SCC-B is intended for installation into the BGI PQ200A. The flow path through an SCC-B is shown, in cut-away in Figure 1. PM10 aerosol enters tangentially. Particles greater that PM2.5 are removed to the grit pot and PM2.5 material is ducted to the filter holder. 2.0 Installation A Model. The SCC-A is an exact replacement for the standard WINS as described in the FRM (3). It may be substituted in any instrument, which currently utilizes a standard WINS. The dimensions of the socket and tenon are identical to the WINS and the overall height is the same. Therefore, the SCC may simply be plugged in as an exact replacement for the WINS in any instrument currently using the FRM standard. It may also be fitted to any instrument operating at 16.7-lpm, which utilizes the EPA standard socket and tenon dimensions. E.g. PQ100. A generic installation is shown in Figure 2. 2.1 Installation B Model. The SCC-B is internally identical to the A model, but is intended to be installed in the BGI PQ200, as a direct replacement for the PQ200 version of the WINS. The installation process is as follows. Step 1. Remove the external first stage inlet and one foot down tube.

Step 2. Open the Impactor/Filter mechanism by turning the T handle counter clockwise. Remove the impactor cup and filter cassette. Step 3. Loosen the round, knurled knob, which secures the lower WINS/upper filter housing and lift out this component. Step 4. Firmly grasp the upper WINS housing, pull down and remove. Step 5. Replace the upper WINS housing with the SCC upper adaptor. Step 6. Install the SCC and rotate so the transfer tube is pointing outwards towards the operator. Tighten the round, knurled knob. Step 7. Install the filter cassette and close the mechanism by rotating the T handle clockwise. Step 8. Adjust the clamping pressure, if required and perform a leak test as described in the PQ200 manual. The SCC-B is shown installed in Figure 3. 3.0 Operation. After installation of the SCC, the instrument may be run in the normal manner at a flow rate of 16.7-lpm. 4.0 Maintenance. The intervals between cleanings of the SCC are dependent upon the concentration at which it is subjected to. Experience indicates that at PM2.5 concentrations of around 10μg/M 3, a three week interval is conservative (1), (2). Cleaning, starting at once a week (7 operational days) is recommended until you have garnered sufficient observational information in your local to utilize longer intervals. An exploded view of the SCC is shown in Figure 4. Recommended cleaning materials are clean mineral free water and lint free lab wipes. In cases where stubborn deposits are observed, ultrasonic cleaning is recommended. To dissamble: Step 1. Remove the SCC from its installed position in the instrument. Step 2. Pull off the transfer tube. If it is too tight to remove by hand, pry it off with a rigid plastic lever.

Step 3. Remove the top cap and grit pot by unscrewing. Step 4. Wet a lint free wipe with water and remove all visible deposits. These are most likely to be found at the bottom of the cone and inside the grit pot. Step 5. Inspect all O rings for shape and integrity. If at all suspect, replace, (with Buna-N elastomer). Lubricate all O rings with light grease. It is important to well lubricate the transfer tube to avoid difficult disassembly. References: (1). L.C. Kenny Investigation of the Effects of Loading on PM2.5 Selectors., HSE Report IR/L/A98/13 (click here to download a copy). (2). L.C. Kenny, Gussman, R.A. and Meyer, M. Development of a Sharp-Cut Cyclone for Ambient Aerosol Monitoring Applications. (In review). (3). Federal Register 40 CFR part 50, July 18, 1997. Figs. L-20 through L-24.

PM 10 AEROSOL FROM INLET GRIT POT 2043 PM 2.5 AEROSOL TO FILTER Figure 1: SCC-B Flow Path

1st STAGE SIZE SELECTIVE INLET BAROMETRIC PRESSURE SENSOR RADIANT SHIELD HOUSING AMBIENT TEMPERATURE SENSOR DISPLAY SCREEN MICRO- PROCESSOR RS232 PORT FIELD COMPUTER OR PORTABLE LOGGER SCC FILTER TEMP SENSOR FLOW SENSOR PUMP EXHAUST 2045 Figure 2: Generic Sampler Showing SCC Installed

Figure 3: Drawing of SCC-B Installed

Figure 4: Exploded View of SCC

VM VERIFIED MANUFACTURE March 2001 Verified Manufacture, a Mark of Origin and Quality. What does it mean to you, the user of BGI Sharp Cut (SCC) and Very Sharp Cut Cyclones (VSCC)? In addition to fabrication and testing in an ISO 9001 facility, BGI Inc. utilizes a Verification Mark. This mark is stamped on all ambient cyclones, of BGI manufacture, after March, 2001. What BGI s Quality Assurance efforts Mean: 1. As part of BGI s continued pioneering efforts in the ambient particulate sciences, the mechanical design for the SCC and VSCC was engineered, developed and manufactured at BGI Inc. 2. The design and commercial product was verified, tested and computer modeled at the Health and Safety Laboratory, Sheffield, UK. ( A U.S. EPA Equivalent Aerosol Testing Laboratory) 1 3. The SCC and VSCC Cyclones have been subjected to field trials and the results published, in peer reviewed journals 2,3. 4. The SCC and VSCC family of cyclones are manufactured in BGI s ISO 9001 facility by experts serving the ambient sampling needs of science and industry for over 30 years. 5. Without the BGI Verified Manufacture Mark, the cyclone may be a back-engineered copy. A SCC or VSCC copy is not equivalent and not reference or design verified. Its application for any verifiable ambient air quality study is potentially problematic. 1. Effectiveness of the PM2.5 Federal Reference Method to Differentiate Fine and Coarse Mode Aerosol, NERL Report. EPA 600/R-00/33, August 2000. 2. L.C. Kenny et al (2000) Development of a Sharp Cut cyclone for Ambient Aerosol Monitoring Applications, Aerosol Science and Technology, Vol.32, No. 4, pp 338-358. 3. R.A. Gussman et al (2001) Design Calibration and Field Test of a Cyclone for PM-1 Ambient Air Sampling, Aerosol Science and Technology (In press). BGI Cyclone Models: SCC A (In partnership with Rupprecht & Patashnick, who s product is also VM marked). SCC - B SCC 2.229 VSCC A & B