Silencer Rubber Underlayment Specifications Name: Silencer Rubber Color: Beige & Silver Type: Sound + Vapor Barrier Construction: High Density Rubber & foil barrier film Coverage: 100sqft Thickness: 2mm Weight per Roll: 36 lbs. Subfloor Compatibility: All Types Floor Compatibility: Laminate Installation Method: Floating Recommended Usage: Residential & Light Commercial STC (Sound Transmission Class): 87 IIC (Impact Insulation Class): 89 Density: 750kg/m 3 Rubber Underlayment provides superb sound and moisture protection. This underlayment will absorb minor imperfections in the sub-floor, giving your laminate floor a smooth, even surface to float upon. Installation Follow the Eternity Laminate Installation Guide for detailed instructions. 1. Prepare the Subfloor. Level, repair, and make sure it is free of debris 2. Begin the first row. Place the roll on the ground with the film side down (facing the subfloor). Note: the overlap of film should be positioned toward the open room and the rubber will face the wall. 3. Measure and cut accordingly. The plank width will determine how many rows of flooring you will be able to install. When you reach 1ft away from the underlayment, stop and roll out a second row of underlayment. 4. Begin the second row. Unroll, measure, and cut. Place the rubber side over the top of the film overlap from the previous row. Butt the edges together to create a nice seam, do not overlap. 5. Tape the Seams. Use industrial tape to adhere the seams together to make a flat & even surface 6. Finish. Continue installation in sections by repeating the steps above. Roll Width: 8in. Roll Height: 40in. Country of Manufacture: China This product, when properly installed and used under normal conditions, is warranted to remain resilient and functional for a period equal to the warranted life of the selected Eternity floor. www.eternityflooring.com

No. : XMML121003928 Page: 1 of 5 The following sample(s) was/ were submitted and identified on behalf of the client as: Sample Name : 3-IN-1 RUBBER ACOUSTIC FOAM Sample Information : OYR-2 Test Performed : Selected test(s) as requested by applicant Date of Receipt : Oct 27, 2012 Test Period : Oct 27, 2012 to Dec 24, 2012 Test result(s) : Refer to the following page(s) Signed for and on behalf of SGS-CSTC Co., Ltd. Civi Huang Xiamen Materials Lab Technical Supervisor

No. : XMML121003928 Page: 2 of 5 Test Information: Sample description: See photo Project description: The test specimen was covered on a 140mm concrete floor with a drop ceiling, Testing area 18m 2, The drop ceiling consisted of 350mm deep steel bar joints spaced 960mm on center, the ceiling construction consisted of 50mm 100mm wood bolted to the bar joints, the wood was spaced 600mm on center, 12mm thick gypsum board were bolted on the wood, glass wool, 100mm in thickness was placed between the joints in the formed cavity; Test item Test method Test condition Result Sound insulation ASTM E492-2009 material performance (See Appendix 1) IIC=89 ASTM E989-2006 test Note: The test was carried out by external laboratory assessed as competent.

No. : XMML121003928 Page: 3 of 5 Appendix 1: Measuring equipment: Sound level meter B&K2260, No.6450501;Tapping machine TM002, No.8790501; Environment: Source room volume 56m 3, Receiving room volume 62m 3, Air temperature 12, Air Humidity 54%. L n f Hz db 50 / 63 / 80 / 100 78 125 90 160 90 200 82.5 250 75 315 67 400 62 500 58 630 52.5 800 42 1000 30 1250 21 1600 12 2000 7.5 2500 6.5 3150 7.5 4000 / 5000 / IIC 89

No. : XMML121003928 Page: 4 of 5 The constructional drawing of the floor/ceiling assembly system

No. : XMML121003928 Page: 5 of 5 Sample Photo: SGS authenticate the photo(s) on original report only ********End of report********

No. : XMML121003927 Page: 1 of 5 The following sample(s) was/ were submitted and identified on behalf of the client as: Sample Name : 3-IN-1 RUBBER ACOUSTIC FOAM Sample Information : OYR-2 Test Performed : Selected test(s) as requested by applicant Date of Receipt : Oct 27, 2012 Test Period : Oct 27, 2012 to Dec 24, 2012 Test result(s) : Refer to the following page(s) Signed for and on behalf of SGS-CSTC Co., Ltd. Civi Huang Xiamen Materials Lab Technical Supervisor

No. : XMML121003927 Page: 2 of 5 Test Information: Sample description: See photo Project description: The test specimen was covered on a 140mm concrete floor with a drop ceiling, Testing area 18m 2, The drop ceiling consisted of 350mm deep steel bar joints spaced 960mm on center, the ceiling construction consisted of 50mm 100mm wood bolted to the bar joints, the wood was spaced 600mm on center, 12mm thick gypsum board were bolted on the wood, glass wool, 100mm in thickness was placed between the joints in the formed cavity; Test item Test method Test condition Result Sound insulation ASTM E90-2009 material performance (See Appendix 1) STC=87 ASTM E413-2010 test Note: The test was carried out by external laboratory assessed as competent.

No. : XMML121003927 Page: 3 of 5 Appendix 1: Measuring equipment: Sound level meter B&K2260, No.6450501;Tapping machine TM002, No.8790501; Environment: Source room volume 56m 3, Receiving room volume 62m 3, Air temperature 12, Air Humidity 54%. f TL Hz db 50 / 63 / 80 64 100 70 125 66 160 63 200 65 250 63 315 69 400 72 500 75 630 77 800 80 1000 81 1250 84 1600 88 2000 88 2500 90 3150 92 4000 94 5000 93 STC 87

No. : XMML121003927 Page: 4 of 5 The constructional drawing of the floor/ceiling assembly system

No. : XMML121003927 Page: 5 of 5 Sample Photo: SGS authenticate the photo(s) on original report only ********End of report********