Getting the best from Wienerberger Bricks A Guidance Note on Garden & Retaining Walls

Similar documents
March Severely

March 2014 ENTER. Severely

The Brick Matching Guide. a Forterra brand

F10. BRICK/BLOCK WALLING To be read with Preliminaries/General conditions. TYPES(S) OF WALLING 110 CLAY FACING BRICKWORK SHALL BE:

F10. BRICK/BLOCK WALLING To be read with Preliminaries/General conditions. TYPES(S) OF WALLING 110 CLAY FACING BRICKWORK SHALL BE:

SERIES NG 2400 brickwork, blockwork and

BDA DESIGN NOTE 7 January 2011 Brickwork durability

Minimum insulation thickness (mm) Built-in insulation

BS EN and PAS 70 Guide to the Standards

BRICKWORK 3.5 BRICKWORK 1 GENERAL

Brick Works (cont.) Building in bricks: Factors affecting the stability of brick building: Properties of bricks:

CHAPTER 7: Superstructure

Balconies Information. How to waterproof and reduce efflorescence

0331 Brick and block construction

Building Construction 7. Dr Nabil El-Sawalhi Associate professor Engineering Projects Management

Structural Masonry Elements

January for brickwork

Learning Text. Part 6. Properties of Masonry Mortar

TECHNICAL INFORMATION LIME SAND MORTARS

Contents BRICKWORK, BLOCKWORK AND STONEWORK. Series NG 2400 Brickwork, Blockwork and Stonework

v 1.1 April 2018 guide to the use of tobermore concrete bricks

December 2017 MORTAR FOR BRICKWORK

Design Guide for the use of Hydraulic Lime Mortar. EcoRight Ltd Unit 2 Paddock Road Caversham Reading Berkshire RG4 5BY Tel:

CHAPTER 10: Finishes CONTENTS 10.1 PLASTERWORK 10.2 SECOND AND THIRD FIX FINISHES. Chapter 10

Weatherproofing Masonry For Northern Climates

Hanson Multicem is manufactured to comply with the requirements of BS EN CEM II/A-LL (Portlandlimestone cement) strength class 32,5R.

NOVEMBER 2016 GRANDWALL. retaining walls installation guide

Technical references for mortar and associated topics

August 2008: Issue 1. Non - Residential New Build 4.5 Basements

BTB 5 BRICK TECHNICAL BULLETIN MOVEMENT CONTROL INTRODUCTION

CHAPTER 10: Finishes CONTENTS 10.1 PLASTERWORK ND AND 3 RD FIX FINISHES

Part 1 General information. Chapter 1.4. Cold weather working

roofing ROOFING Design of the base ROOFING DETAILS

Brick properties and bricklaying practices

Technical Manual - Section 18 Lytag Bagged Aggregate. Introduction 2. Physical Properties of Lightweight Aggregate 2.

tra-load Damp Proof Courses Product and Systems Overview

August 2016 DESIGNING FOR MOVEMENT IN BRICKWORK

Building in a Saline Environment

June Non - Residential Refurbishment 5.5 Basements

Technical references for mortar and associated topics

June Residential Refurbishment Basements

PAGE 415. Part 9. External works. 9.1 Garages. 9.2 Drives, paths and landscaping

TIVOLI CARPARK SITE DEVELOPMENT, LITTLE COLLINS STREET, MELBOURNE BRICK AND BLOCK CONSTRUCTION

APPROVALS. Jabwall has been approved for this application since 1979, and was the first partial-fill insulation product to gain BBA approval.

The Brick Matching Guide. a Forterra brand

Brick Slip Application Guide

Polyfoam Floorboard For thermal insulation of floors

Section 02 SUBSTRUCTURE

SERIES 1100 KERBS, FOOTWAYS AND PAVED AREAS

SECTION SELF-ADHERING SHEET FLASHING

TECHNICAL SHEET #11. Remedial Practice to Safeguard Face Bricks & Mortar Joints from Sea Spray Attack. Technical Contributors

Sheetseal 226 RIW. Sheetseal 226

Part 5 Substructure and ground floors. Chapter 5.2. Suspended ground floors

Xtratherm Thin-R Partial Fill Cavity Wall Board (XT/CW Grade)

Facing Bricks. elegant, timeless, inspiring...

2002 Advanced Building Products, Inc., P.O. Box 98, Springvale, Maine TEL: ; FAX: ; WEBSITE:

BUILDING STONE PRODUCTS, INC.

Clay and clay products

GUIDELINES FOR RETAINING WALLS 4-0 IN HEIGHT OR LESS

freestone eco Prestige & quality DIY vertical wall Large blocks - 10/m 2 Smooth surface finish No concrete footings

Jabfill High Performance (HP)

850 SOLID LIGHTWEIGHT READYBLOCK

Ketley Special Shape Bricks

TECHNICAL NOTE #36. Durable clay brick protecting property from fire and flood TECHNICAL CONTRIBUTOR

84 Lapping & Jointing 86 Service Pipe Penetrations 87 Sealing to Cavity Wall Constructions 88 protecting Membranes 90 System Components.

v 2.2 February 2018 country stone in stodck availabl walling

Specifications. Some details shown in this document have been reproduced from CCANZ document CP 01.

Adobe Brick Construction. Adobe

a new liquid screed solution

CemWash. the cement innovation company

AS The External Waterproofing Membranes Standard

INSTALLATION METHOD STATEMENT

TECHNICAL INFORMATION SCREED

Retaining Guide. TerraFirm mm. 500mm (typical)

POZZOLANIC CEMENT Fly ash based (CEM IV/B-V 32,5N) Properties & Applications

50948-RHN Putney. 06 January This document includes: F30. Accessories/ sundry items for brick/ block/ stone walling. Code Section Revision Dated

Ground Terraces. bal-adhesives.com. Part B: Installation Guide

REFLECTIVE FACE CONCRETE MASONRY UNITS

HP Partial Fill. Robust, long-lasting protection

ALLNEX DAMP PROOF AND TANKING MEMBRANES. Product. Scope. Appraisal No. 805 [2013] Appraisal No. 805 (2013) Amended 26 January 2018.

SPECIFICATION GUIDELINE

STUDY ON WETTING AND DRYING OF CLAY BRICK HAVING SURFACE COATINGS

LAYING IBSTOCK CLAY PAVERS FOR PERMEABLE PAVEMENTS

REINFORCED CONCRETE MASONRY SECTION

EN REINFORCED MASONRY DESIGN EXAMPLE 1 (NOTE: THIS USES THE UK NATIONAL ANNEX NDP VALUES)

ECO PHOENIX CEMENT (fly ash based) BS EN CEM IV/B-V 32,5N Properties & Applications

FUNCTIONAL REQUIREMENTS

MASONRY CHIMNEY CHECKLIST FOR WEATHER RESISTANCE

Xtratherm Thin-R Underfloor Board (XT/UF Grade)

Redi Rock Specification and Installation Manual

Module 10: Masonry walls

TECHNICAL INFORMATION CEMSCREED 5

Floor Screeds & Compounds

Building Construction 14. Dr Nabil El-Sawalhi Associate professor Engineering Projects Management

Designer Block SOUTH QUEENSLAND

tra-load Tanking Membranes Product and Systems Overview

Sheetseal GR RIW. Sheetseal GR

SPECIFICATION GUIDELINE

DESIGN TIPS TECHNICAL BULLETIN #47 FLASHING, WEEP HOLES AND RELATED ANCHORAGE [1 of 8]

Transcription:

Getting the best from Wienerberger Bricks A Guidance Note on Garden & Retaining Walls Introduction Correct construction and detailing of freestanding garden and retaining walls is important to ensure long term performance. These are especially at risk irrespective of geographical location, because they are often in exposed and unprotected areas and are subject to saturation, frost, sulfates and low temperatures. While all of these issues need to be considered, brick is an excellent choice of material and with the correct detailing will provide satisfactory performance for years to come. Structural Considerations This guide deals with the design for durability of domestic garden and retaining walls where forces and loadings are minimal. Professional guidance should be obtained for retaining walls above 1m in height and for freestanding walls above 1.2m. Brick Selection All of our bricks are manufactured in accordance with the European Standard BS EN771-1 : 2003. We recommend that for any garden or retaining wall a brick with a durability designation of F2 is selected. It is also worth noting that all of our products are within the lowest category (S2) of active soluble salts content. F2 rated bricks are frost resistant, confirming them as suitable for building details of severe exposure, where units may be saturated and subjected to repeated freezing and thawing. They can be used for walls at or below ground level, for external free standing walls including cappings, and for retaining walls. Therefore F2/S2 bricks must be specified. Detailing to minimise the water content of masonry will prolong its life. We also recommend that copings and cappings be formed from smooth textured bricks or special shapes, to maximise water shedding. At the base of the wall, at least two courses of Engineering bricks or creasing tiles in M12 category mortar will provide an effective barrier to rising damp without compromising the wall s structural performance. Coping and Capping of Brickwork Correct finishing of the head of a wall adds visual appeal and has important benefits in terms of protecting the brickwork beneath from water ingress and staining. Copings and cappings can vary in appearance from a standard brick on edge to bullnoses, cants, angles and curves. A series of standard shapes are available under BS4729 (Specification for dimensions of bricks of special shapes & sizes) and if required units can be designed and manufactured specifically for a project. The definitions of a coping and capping are as follows: Capping Sits flush with the vertical face of the wall. Coping Projects at least 40mm from both sides of the wall and incorporates a drip on the underside. Copings provide better protection because they shed water clear of the vertical face of the wall. It is important that a brick with a durability designation of F2/S2 is selected, with a smooth texture being preferable. Refer to figure 1

figure 1 Examples of Copings and Cappings CP.2 CP.1 BN.2 CP.1 Saddleback Coping Half-round Coping Creasing tiles & Double Bullnose Capping to form Coping Half-round Capping CP.2 AN.6 BN.2 Creasing tiles & Saddleback Capping to form Coping Creasing tiles & Double Cant Capping to form Coping Double Bullnose Capping Brick on Edge Capping

Damp Proof Courses & Waterproofing We advocate good site practice of providing a suitable membrane to prevent percolation of water and the effect of longer term staining from ground salts and leaching of mortar. With this in mind it is important that a waterproofing membrane (DPM) or liquid applied coating should be applied to the rear face of any retaining wall. This DPM should be protected from damage by a suitable protective board. It is also good practice to incorporate a damp proof course near the head of the wall. It is usual to place the DPC two courses down to increase stability, particularly with brick on edge cappings. DPC s should be sandwiched in fresh mortar. At the base of the wall sheet DPC s should be avoided. The use of two or more courses of engineering bricks or creasing tiles (with staggered joints) will provide good resistance to rising dampness without affecting structural performance. Refer to figures 2 and 4 Creasing Tiles Creasing tiles have been used for many centuries as a means of shedding water and preventing dampness in walls as well as for visual effect. Their resistance to moisture and their ability to form a strong bond with mortar make them an ideal damp-proofing medium for garden and retaining walls. By projecting them from both faces of the wall (minimum 40mm) they can also provide a protective drip feature to form a coping detail. At the base of the wall creasing tiles will also provide a resistance to dampness due to their low water absorption. It is important to note that a minimum of two courses should be specified with staggered joints. Refer to figure 3 Drainage Water accumulating behind a retaining wall exerts pressure and needs to be released. This is critical to prevent structural damage. This can be achieved by incorporating a drainage layer, generally a granular material (gravel), with land drains and weepholes at regular intervals. A plastic pipe through the wall will normally suffice. Leaving open perpend joints to release water can lead to localised wall saturation and staining, with potential effects on long term durability. Gravel splash strips adjacent to the wall faces, at ground level, reduce the risk of saturation near the base of the wall. Adjacent paving should be laid to falls, sloping away from the wall, to reduce the saturation risk.

F2/S2 rated coping with smooth texture M12 class mortar M6 class mortar for the main body of the wall (M4 class for stock bricks) * Three courses of Engineering bricks in M12 mortar (minimum two courses above ground level) Weepholes/pipes at regular intervals (every fourth brick) Paving laid to falls (sloping away from the wall) in M12 mortar below ground level Topsoil Free-draining granular material Waterproof membrane or liquid applied coating applied to the rear face of brickwork. Must be protected from damage Land drain draining to a suitable collection point Retained earth M12 class mortar at and below level of engineering bricks Concrete foundation figure 2 Retaining Wall Up to 1m in height * NOTE: Where there is no DPM or there is a risk that it may not be effective sulfate resisting cement should be used.

F2/S2 rated capping with smooth texture M12 class mortar Two courses of creasing tiles with staggered joints and projecting at least 40mm from the face of the wall provides a protective drip feature and an effective coping detail M6 class mortar for the main body of the wall (M4 class for stock bricks) Two courses of creasing tiles in M12 mortar, with staggered joints Gravel splash strip in M12 mortar below creasing tile level Concrete foundation figure 3 Freestanding Garden Wall (up to 1.2m in height) With creasing tiles and capping

Brick on edge capping. with smooth texture M12 class mortar High bond DPC sandwiched in fresh mortar and projecting beyond the face of the wall M6 class mortar for the main body of the wall (M4 class for stock bricks) Three courses of Engineering bricks in M12 mortar (minimum two courses above ground level) Paving laid to falls (sloping away from the wall) Gravel splash strip in M12 mortar below ground level Concrete foundation figure 4 Freestanding Garden Wall (up to 1.2m in height) With brick on edge capping

Mortar Consideration should be given to the appropriate mortar specification for different applications. M12 M6 M4 For cappings, copings and work at and below the base DPC. For the main body of the wall in all exposure zones. For the main body of the wall when using stock type bricks or in sheltered zones, with the correct detailing. British Standard Categorisation of Mortars Table NA2 in the National Annex to BS EN 1996-1-1 (Eurocode 6) Mortar Designation Compressive Strength Class Cement : Lime : Sand with or without air entrainment Prescribed Mortars (proportion of materials by volume) Cement : Sand with or without air entrainment Masonry Cement a : Sand Masonry Cement b : Sand Compressive Strength at 28 days (N/mm²) (i) M12 1 : 0 to ¼ : 3 - - - 12 (ii) M6 1 : ½ : 4 to 4½ 1 : 3 to 4 1 : 2½ to 3½ 1 : 3 6 (iii) M4 1 : 1 : 5 to 6 1 : 5 to 6 1 : 4 to 5 1 : 3½to 4 4 a Masonry cement (inorganic filler other than lime) b Masonry cement (lime) Notes: Proportioning by mass will give more accurate batching than proportioning by volume, providing that the bulk densities of the materials are checked on site. When the sand proportion is given as, for example, 4 to 5, the lower figure should be used with sands containing a higher proportion of fines whilst the higher figure should be used with sands containing a lower proportion of fines. Sulfate Attack If there are sufficient soluble salts or sulfates presents in a mortar containing tri calcium aluminate (C3A) and there is enough water present (for long enough) expansion of the mortar can be caused, eventually causing total disruption of the mortar joints. This rare problem is called sulphate attack. The salts/sulfates usually come from the earth behind a retaining wall, from salts used for de-icing purposes or very rarely from the bricks themselves. To reduce the risk of sulphate attack, S2 designation bricks should be specified. Design and construction measures should minimise the ingress of water into the brickwork for example DPC s, copings, DPM s behind retaining walls and paving laid to fall away from the wall. A further precautionary measure would be to use sulphate resisting types of cement (SR grades) where there is a risk of contamination.

Movement Joints Clay bricks, like all materials, expand and contract as temperature rises and falls. Whilst thermal expansion of the brick will occur due to the range of temperatures experienced, the orientation of walls and the colour of the brick, a greater influence on the overall movement of clay bricks is the long term effect of moisture. The location and size of movement joints must therefore take into account the overall thermal and moisture movement characteristics of the product, the design and the dimensions of brickwork panels, and their relationship in plan form. For simplicity in garden and retaining walls a movement joint spacing of maximum 6m is advised. Vertical joints should commence from foundation level and extend through any coping or capping feature. It is important that an easily compressible joint filler material is specified. Cellular polyethylene and cellular polyurethane are ideal materials. The face sealant should offer long term protection of the joint filler and various sealant colours are available to complement mortar colours. Refer to figure 5 Mortar Joint Profiles To maximise the water shedding properties of the brickwork it is advised that mortar joint profiles have a bucket handle (preferred), weather struck or flush finish. It is also important that any joint is well tooled. Recessed joints are not recommended because they hold water, encourage longer term staining and are less resistant to rain penetration. Refer to figure 6

figure 5 Typical Movement Joint Detail Plan Compressible joint filler material (cellular polyethylene or cellular ployurethane) Sealant figure 6 Damp Proof Course (DPC) and Mortar Joint Profiles Section High bond DPC sandwiched in fresh mortar and projecting beyond the face of the wall (min 5mm) Bucket handle mortar joint (preferred profile) Weather struck mortar joint Flush mortar joint

Checklist of Essential Points A brick with a durability designation of F2 and an active soluble salt content of S2 must be selected (F2/S2). Correct mortar specification and joint profile selected (bucket handle joint preferred). All mortar joints well tooled. Consider the risk of sulphate attack and specify correct the materials and details needed to prevent it from occurring. The DPC at the base of a wall must be constructed from engineering bricks or creasing tiles and should comprise at least two courses as shown. A high bond DPC sandwiched in fresh mortar should be included near the head of the wall. Suitable coping or capping to be selected. Copings are preferred. A waterproofing membrane (DPM) or liquid applied coating should be applied to the rear face of a retaining wall. This needs to be protected from damage. Suitable drainage to prevent water retention must be provided behind a retaining wall. With weepholes/pipes at regular intervals. Movement joints should be included at maximum 6m centres (including copings and cappings). Gravel splash strips adjacent to the wall faces, at ground level. Paving laid to falls, sloping away from the wall. Further Information & Resources This document has been developed to provide general guidance. For more detailed advice on specific applications please contact our Technical Design Services Department. Wienerberger Technical Design Services Department 0161 491 8200 Please note that this guidance is considered to be an enhancement of the previous BS5628 Part 3 information which was withdrawn in 2010.