Sampling Day Activities

Similar documents
Biochemical Oxygen Demand

Measuring Dissolved Oxyg Instructions for the La Motte Field-Test Kit

BACKGROUND: The following is adapted from the Watershed Cruzin Guide:

BOSQUE ECOSYSTEM MONITORING PROGRAM River or Ditch Water Quality Sampling

Demonstration of Relationship between CO2 and ph Instructions

With Discovery Incubator.

FIELD PROCEDURE: TURBIDITY

To whom it may concern, February 21, 2011

A natural impurity in water. The test will measure the amount of free oxygen "gas" dissolved in your water sample in ppm (mg/l).

Most Probable Number (MPN) & Biological Oxygen Demand (BOD)

Dissolved Oxygen. LabQuest INTRODUCTION

HYDROLOGY INVESTIGATION Electrical Conductivity. What is Conductivity?

Methods and Materials Manual Of Ion Chromatography Using DX-100 IC. Collecting Samples. LDPE bottle with cap (pre-rinsed with DI water)

Direct ISE Method Method to 4.00 mg/l NO 3 N Nitrate ISE

Collecting a Surface Water Sample

MSES consultants, inc.

Easy Well Water Test Kit Pro with Bacteria, lead and Pesticide Instructions

Sample for Use as a Guide Revised IDEXX ENTEROLERT TEST METHOD FOR THE DETECTION OF ENTEROCOCCI IN WATER

Oxygen Demand, Chemical

Mosquito Larvae Protocol Mosquito Larvae Sampling Field Guide

STANDARD OPERATING PROCEDURE FOR THE COLLECTION OF CHEMICAL AND BIOLOGICAL AMBIENT WATER SAMPLES

PROTECTING THE WACCAMAW WATERSHED. Water Quality Monitoring. Christine Ellis. Waccamaw RIVERKEEPER A Program of Winyah Rivers Foundation

BACTERIAL TRANSFORMATION LESSON PLAN

OPERATING INSTRUCTIONS

Standard Operating Procedure (SOP)

WATER QUALITY; WHY IS IT SO IMPORTANT?

Scope and application: For water and wastewater. Turbid samples are filtered during the analysis.

Surface Water Quality Sampling Instructions. Surface Water Quality Sampling Instructions

Nitrogen, Simplified TKN (s-tkn )

2015 CORNELL SOIL HEALTH TRAIN-THE-TRAINER WORKSHOP AUGUST 5-8, 2015 ITHACA, NY. Wet Aggregate Stability Test

Identify and Correct Impact of Water Health Challenges Associated with Flooding. Susan Watkins and Mike Daniels

Human CRP Precoated ELISA kit

Color, True and Apparent, LR

WESTPAC Training Workshop Research and Monitoring of the Ecological Impacts of Ocean Acidification on Coral Reef Ecosystems

MAINTENANCE & CALIBRATION: HF TURBIDIMETERS Rev. 4/5/16

Manual No Revision MODEL GLI HAND-HELD/PORTABLE TOTAL/FREE CHLORINE METER

Collecting a Surface Water Sample

Phosphorus, Reactive (Orthophosphate)

RIVER MONITOR MANUAL

HACH TU 5 SERIES TURBIDIMETERS SOP: COMPARISON LAB AND PROCESS. The next standard in the evolution of turbidity

Human DNA Alu Amplification by Polymerase Chain Reaction (PCR)* Laboratory Procedure

CH 112 Special Assignment #6 The Case of the Phony Fruit

PENNSYLVANIA S CITIZENS VOLUNTEER MONITORING PROGRAM TSI (Trophic State Index) LAKE MONITORING PROGRAM

3. Add 0.4 ml of. 7. Use a TenSette

Sample for use a Guide Revised IDEXX COLILERT -18 TEST METHOD FOR THE SIMULTANEOUS DETECTION OF TOTAL COLIFORMS AND E.

seven mm screw top bottles Vernier computer interface shallow pan Vernier Dissolved Oxygen Probe scissors Logger Pro

Centre d expertise en analyse environnementale du Québec

CHEMICAL ENGINEERING LABORATORY CHEG 4137W. Bioreactor

Copper Odyssey. Chemical Reactions of Copper

Standard Operating Procedures for Tidal Monitoring

Standard Operating Procedures for Tidal Monitoring

ab TIMP2 Human ELISA Kit

VAN LONDON COMPANY COMBINATION ph ELECTRODE INSTRUCTION MANUAL

Method 8017 (0.7 to 80.0 µg/l) Powder Pillows. Scope and Application: For water and wastewater; digestion is required to determine total cadmium.

edna PROTOCOL SAMPLE COLLECTION Caren Goldberg and Katherine Strickler, Washington State University Revised November 2015

CHEMICAL ENGINEERING SENIOR LABORATORY CHEG Bioreactor

Again, thanks for interest in this project. Please let me know if you have any questions, and I look forward to working with you.

CHEMICAL/BACTERIA KIT - FLUIDS

Direct ISE Method Method to 10.0 mg/l F Fluoride ISE

Standard Operating Procedures for Non-tidal Monitoring

edna PROTOCOL SAMPLE COLLECTION Caren Goldberg and Katherine Strickler, Washington State University Revised January 2017

ab IL10 (Interleukin-10) Canine ELISA Kit

Instruction Manual HI Portable ph/ec/tds/ C Meters

ab MBL (Mannose-Binding Lectin) Human ELISA Kit

OPERATING INSTRUCTIONS. Portable Turbidity Meter

Standard Operating Procedures for Non-tidal Monitoring (Tier I and Tier II)

CEE 311 Environmental Engineering I Fall 2015 Dr. Jagadish Torlapati BIOCHEMICAL OXYGEN DEMAND (BOD)

EVENT: Perform the following steps of a BOD analysis using the YSI ProOBOD Optical BOD probe.

Zinc Testing and On Site Calibration for Water Testing Detection Range: 1 15ppm

He eia Fishpond Water Monitoring Project Due:

Purpose: Drive library fragments to ISPs (beads) and populate the beads with empcr. Quantify the yield using the Qubit..

ab FAP Human ELISA Kit

23, SEDIMENT COLLECTIONS

ab CD163 (M130) Human ELISA Kit

3. Add 0.4 ml of. 7. Use a TenSette

An Oxidation-Reduction Titration: The Reaction of Fe 2+ and Ce 4+

DNA TRANSFORMATION OF BACTERIA RED COLONY REVISED 3/2003

Group Stormwater Compliance Program Sampling Instructions

Nebraska Soil Science Curriculum

From Turbid to Clear: How Flocculation Cleans Up Drinking Water

Science in the Schoolyard Guide: FOSS California Water Planet. Investigation 3 Evaporation Locations

Photo tour of the monitoring activities found in the Stream Side Science manual

EXPERIMENT 7A. Chemical Separation by Filtration and Recrystallization INTRODUCTION

Sulfate. USEPA 1 SulfaVer 4 Method 2 Method to 70 mg/l SO 4. Powder Pillows. Test preparation. Before starting.

Microbes All Around Us

EHS SMART-Treat Onsite Moving Media Treatment System

Oxygen Demand, Chemical

By Authority Of THE UNITED STATES OF AMERICA Legally Binding Document

COLORIMETRIC SANDWICH ELISA KIT INSTRUCTION MANUAL

Electroelution. Teachers Handbook. (Cat. # BE 602) think proteins! think G-Biosciences

Transcription:

Sampling Day Activities Approved by: WWA Director Reviewed by: Volunteer Monitoring Coordinator On the day of sampling, the following activities are to be conducted at the sampling site in the order presented below: 1) Give the meters and sensors time to adjust to ambient temperatures at the sampling site using the procedures described below. This step is important during times of the year when temperatures indoors are quite different from outdoor temperatures. Avoid leaving the meters in a hot car for more than a few minutes. At the sampling site, try to keep the meters out of direct sunlight. 2) When you get to your sampling site, look around to see if anything unusual is going on. Note this on your field data sheet in the comments section. Fill out the weather and stream flow conditions and information on the last known rainfall. Note the sampling date and time. If the sampling site is currently occupied by boats, people, etc., move to a nearby location, trying to stay as close as possible to the original site. Note any relocation and potentially contaminating activities on the field data sheet. Remove the sampling equipment and meters from the car and transport them to the sampling site. Remove the handheld meters from the sampling kit bucket. Allow your meters, sensors and calibrating solutions to stabilize at the ambient temperature of your first sampling site before performing your field calibration checks on the Orion Star A329 meters for DO, %DO, conductivity and ph.* *NOTE: You can perform these field checks at home immediately prior to sampling. Consult each parameter s standard operating procedure (SOP) for more details. If a parameter fails a field calibration check, i.e. it is outside the acceptance range notes on your field data sheet, follow the directions in the parameter SOPs to troubleshoot or call the Volunteer Monitoring Coordinator for assistance (see contact list in your field notebook). 3) Obtain water samples for each of turbidity and bacteria as follows: Page 1 of 6

a) Triple rinse the 2 liter insulated polyethylene (PE) bottle attached to the sampling pole three times as follows. Place the pole into the water just downstream of your specific sampling location, fill the bottle with water and then pour it out slightly downstream. Repeat two more times. You have now effectively cleaned your bottle by triple rinsing it. Alternatively, a turbidity sample can be obtained directly from the source using the turbidity bottle, following triple rinsing as indicated for the 2 L bottle described above. b) Label the small 30 ml sterile bacteria sampling bottle and attach to the sampling pole with rubber bands or bungees provided. Carefully remove the top from the bottle taking care not to touch the top rim of the bottle. To do this, hold the bottle by its side, keeping fingers away from the top rim. Do not touch the inside of the cap. To do this, hold the cap by its outside as shown in Figure 1. Place the cap with its top down on a flat surface. DO NOT RINSE the sterile bacteria sampling bottle. Alternatively, the bacteria sample may be obtained directly from the source by placing the sterile bottle directly in the water at the sampling site. c) Place the pole in the water at the sampling site about 1 foot below the water surface to fill the 30 ml sterile bottle and the 2-L cleaned insulated PE bottle. REMEMBER DO NOT RINSE the sterile bacteria bottle. d) Carefully replace the cap on the bottle taking care not to touch the inside of the cap or the rim of the bacteria bottle. Remove the capped bottle from the sampling pole. Place the capped bottle in a ziplock bag, seal, and store on ice in the sampling cooler. Note: Bacteria samples need to be plated within eight (8) hours of sample collection. 4) Using the water in the 2-L insulated PE bottle, fill the 1-L wide-mouth plastic bottle about 2/3 s full. This water will be used to temperature equilibrate your meters sensors. This will make your final sensor measurements less prone to drift and hence speed up your measurements. Put the filled bottle into your sampling kit bucket to prevent it from tipping over and then submerge your sensors in this water.* Wait about 10 minutes for the sensors to reach the temperature of the water. Press the MEASURE button to activate the meters. If the meters lock on a reading, press the MEASURE button to reactivate them. While the sensors are temperature equilibrating, collect your turbidity sample and perform the nutrient measurements. *NOTE: Make sure that you have removed the cap from the DO sensor and taken the ph sensor out of its bottle of buffer. Rinse the ph sensor with deionized water before submerging it in sample water, being careful not to submerge the probe above the blue line. Page 2 of 6

5) Turbidity measurement a) Collect water for turbidity analysis. You have two options. From the water that is left in the 2 L sample bottle, you can pour your sample directly into the turbidity glass vial or into a labeled 500-mL polyethylene bottle and fill the vial from this bottle. In either case, first rinse your sample container (e.g. the glass vial or polyethylene bottle) three times with sample water before filling to ensure that it is clean. b) If the turbidity is not going to be measured immediately in the field (i.e., you prefer to take the sample to another location for measurement), use the 500-mL bottle and make sure to store it in the dark. It does not have to be stored on ice. However, if it will be more than four hours before the turbidity is measured, then the sample needs to be put in the ice in a cooler. The turbidity samples need to be analyzed within 48 hours of collection. *NOTE: Keep the Gelex standards and the turbidity meter out of direct sunlight. c) For turbidity analysis, follow the Standard Operating Procedure for Turbidity (SOP- TURBIDITY) in the field notebook. d) Record the turbidity values on the Turbidity datasheet. 6) Nutrient analyses a) Use the remaining water in the 2-L insulated PE bottle to perform the ammonia, nitrate, and nitrite measurements b) Follow the Standard Operating Procedure for Nutrients (SOP-STRIPS, VM SOP 410) in the field notebook (instructions are also provided on the nutrient strip bottles). The test strips enable a semi-quantitative determination of nutrient levels. To find the best color match, make an educated guess in consultation with the sampling team. *NOTE: Before using, check the strips to make sure that they have not become contaminated. Do this by ensuring that the indicator pad is similar in color to the value of zero (0 ppm) as shown on the bottle s color guide. Figure 2. Color guides on the bottles for the nitrate/nitrate and ammonia tests. c) Record the nutrient concentration results on the field data sheet. 7) Orion Star A329 meter measurements Page 3 of 6

a) Refill the 2-L insulated PE bottle with a fresh water sample collected from the sampling location. There is no need to triple rinse again unless you notice debris in the bottle. b) Transfer the three Orion Star A329 probes from the 1-L plastic wide mouth bottle into the 2 L insulated PE bottle filled with fresh sample water. Discard the water in the 1-L plastic wide mouth bottle. Gently swirl the probes to make sure that no air bubbles are trapped within and on the probes. This also helps the probes to equilibrate faster. Be careful not to submerge the ph probe above the blue line. c) Measure parameters in the following order, watching for measurement drift by looking at the last two readings and comparing them to the criteria listed on the field datasheet for each parameter. If you exceed the drift criteria, take more readings until your last two readings are within the drift criteria. Write the additional readings in the rows for Replicates for 4 and (5) in the space provided. i. Dissolved Oxygen mg/l, % Dissolved Oxygen, and temperature measurement* - Follow the Standard Operating Procedure for Dissolved Oxygen (SOP-DO, SOP VM 402) in the field notebook. Record the results on the field data sheet. ii. iii. *NOTE: Keep an eye on the temperature sensor. It is the metal button located on the side of the probe. Make sure it is not exposed to direct sunlight or warmer water at the top of the sample container. *NOTE: The Dissolved Oxygen probe stabilizes slower when temperatures are high (summer) and the ph probe stabilizes slower when temperatures are low (winter). Conductivity and temperature measurement - Follow the Standard Operating Procedure for Conductivity (SOP-COND, SOP VM 401) in the field notebook. Record the results in the field datasheet. ph* and temperature measurement - Follow the Standard Operating Procedure for ph (SOP-pH, SOP VM 403) in the field notebook. Record the results in the field data sheet. *NOTE: When the sample s conductivity is less than 100 S/cm, the ph meter will take 10-15 minutes to fully stabilize in your sample. As the drift rate slows, the meter will lock onto a reading, so keep pushing the MEASURE button to reactivate the meter. Once 10 minutes has passed, you can try taking your first measurement. The meter should lock onto a stable ph reading quickly. Check for drift using the criteria on your field datasheet. If you are not meeting the criteria, let the sensor equilibrate for another 5 minutes by pushing the MEASURE button to reactivate the meter. If the ph measurements are still drifting after a total of 15 minutes, call the Volunteer Water Quality Monitoring Coordinator to discuss. d) Emergency Procedure If you have technical problems, please call the Volunteer Coordinator for help. If the problem persists, a spare bottle has been provided for emergencies. Triple rinse the emergency bottle to ensure it is clean, then collect a Page 4 of 6

water sample. Fill the bottle so that there are no air bubbles, label the bottle with the date, time and location, store it on ice in your cooler and call us for pick up. e) After completing the meter measurements, remove the probes from the 2-L insulated PE bottle. Rinse each probe with deionized water (DI water). Blot them dry. Replace the cap on the DO probe. Insert the ph probe into the bottle with buffer solution and tighten the cap. Return the conductivity probe to the holder on the meter. 9) Drain the water from the 2-L insulated PE bottle either on the ground nearby or back into the water*. *NOTE: Rinse the 1-L and 2-L bottles with deionized water by pouring in about 0.5 inches of deionized water into each bottle. Swish the water around and then discard. Do this three times. This will make sure that your sampling bottles are clean and ready for the next sampling event. 10) You have now completed the measurements using the Orion Star A329 meters and these may be returned to the sampling kit bucket.* *NOTE: Make sure that you replace the meters in the bucket being careful not to kink the wires near where the probes plug into the meters. 11) You have now completed all field activities. You have obtained water quality measurements in the field for the following parameters: Dissolved Oxygen, Temperature ph, Temperature Conductivity, TDS, Temperature Nutrients Ammonia, Nitrate, Nitrite Turbidity (either in the field or completed within 48 hours of field sampling) 12) Double check that the field data sheets have been completed entirely. Check that there are no blank spaces on the sheet. If blanks exist, complete as appropriate with information or with NA. 13) Ensure that equipment is clean and properly stowed in the sampling kit bucket for transport. 14) At home, perform the E. coli measurements (see SOP-E. Coli, SOP VM 501). a) Complete the field data sheet for bacteria counts. 15) Upload the data and mail the completed data sheets using the pre-stamped labeled envelopes to the Volunteer Water Quality Monitoring Coordinator (reference Form VM1000). Page 5 of 6

REVISION HISTORY SOP Revision # Revision Date Section Modified Modification Reason Changed 1 9/7/16 All Added header/footer to include program name, SOP number, revision date/number, issue date, and page numbering. Added approval sign offs and revision history sections. Updating for better document control. Updated meter used from Hach SensION to Orion Star A329. Revised meter information. All Proofreading edits by Christine Ellis To improve clarity and fix typos. Page 6 of 6