Uniclass L52944:P71 EPIC E375:X71 CI/SfB (47) In6 Pipe Flashing Systems

Pipe Flashing Systems The widest range of pipe flashings available to the market Contents Page Front Cover 1 Contents 2 Introduction 2-3 Pipe Flashing Systems for metal roofs AD Series 4-8 MS Series 9 Fixing Kits 10 Selector Guide 11 Stripflash 12 Expansion Joint 13 Pipe Flashing Systems for slate and tiled roofs VL Series 14-15 VA Series 16-17 Installation Instructions 18 Selector Guide 19 Pipe Flashing Systems 20-21 for solar systems Pipe Flashing Systems for flat roofs FR Series 22-24 RFR Series 25 MR Series 26-27 Back Cover 28 Ventra Supplies January 2010. All rights reserved.

Pipe Flashing Systems 3 So many applications... Pipe flashings provide a durable, flexible, weatherproof seal, for a vast range of applications. These include sealing around pipes, vents, ducts, chimneys, electrical cables, solar pipework, and other services that pass through the building envelope. Pipe Flashing Systems Problem solving products... Sealing around penetrations through buildings is an important issue. Weather sealing of the external building envelope is a vital concern. Air sealing of buildings is becoming an increasingly crucial element in meeting prevailing construction standards and regulations. Penetrations through buildings can cause problems. Our pipe flashing systems are purpose designed to provide the solution and have been proven over many years of service in demanding and challenging construction environments around the world. Extensive range... We offer from the stock the widest range of pipe flashings and ancillaries available to the market. These products are divided into three main groups: Pipe Flashing Systems for metal roofs Pipe Flashing Systems for slate and tiled roofs Pipe Flashing Systems for flat roofs

4 Pipe Flashing Systems for metal roofs Pipe Flashing Systems For metal roofs V-SEAL pipe flashings provide a flexible, durable, weatherproof seal where penetrations pass through the metal, plastic or fibre cement roofing and cladding of the building envelope. AD Series (pages 4-8) Pipe flashings for pipe diameters from 10mm to 750mm to suit standard or retrofit applications. MS Series (page 9) Pipe flashings for cable and pipe diameters from 3mm to 90mm. Fixing Kits (page 10) Purpose designed fixing kits for installing V-SEAL pipe flashings. Providing solutions by design AD Series and MS Series Retrofit Seam Sleeve Base Base The square base design facilitates easy installation, particularly on profiled material where it is notoriously difficult to cut a perfectly round clearance hole. The aluminium support ring provides reinforcement where self drilling screws or rivets fasten the flashing to the roof. A malleable grade of aluminium allows the base to be easily formed to the profile or contours of the roof sheet. Retrofit Seam (AD Series ONLY) See page 5 for details on this unique design feature. Sleeve Each flashing suits a wide range of pipe sizes and has pipe diameters marked on the ribbed measurement lines. This provides an easy identification of the size ranges and helps guide an even cut around the cone. The flexible sleeve allows the pipe flashings to be installed on flat or pitched roofs whilst maintaining their shape and avoiding the collection of water and dust. The sleeve also allows for expansion, contraction and building movement whilst maintaining a weatherproof seal. Materials The pipe flashings are available in EPDM (for cold pipes) and silicone (for high temperature pipes). These materials are of the highest quality and are resistant to ozone and ultra violet light. The manufacturers state that the flashings have a 20 year product replacement warranty against faulty manufacture or materials. Ethylene Propylene Diene Monomer (EPDM) Rubber: Temperature range 40 C to +115 C. Silicone Rubber: Temperature range 60 C to +240 C. Aluminium Support Ring: Grade A1200-0, 1mm thick. Due to a policy of continuous development, we reserve the right to change product specifications and descriptions without prior notice. January 2010.

Pipe Flashing Systems for metal roofs 5 AD Series for retrofit applications A key feature of the AD Series pipe flashings is their adaptability they can be used for both standard and retrofit applications. For most installations the pipe flashing can be pulled down from the top of the pipe but in some situations this is not possible because of obstructions such as cowls, collars, brackets etc. In these circumstances the unique design of the AD Series pipe flashings means they can simply be cut down the seam, wrapped around the penetration and then crimped together using the VSRFC retrofit clips and fixed to the roof material in the usual manner. AD Series pipe flashings one range standard or retrofit. Standard applications use the AD Series pipe flashings only. Retrofit applications use the AD Series pipe flashing + VSRFC retrofit clips. Installation instructions 1. Cut rubber cone to size along marked measurement lines using sharp pair of scissors or knife. Hole size of cone should be cut minimum 15mm smaller than outside diameter of pipe. 2. STEP 2 ONLY APPLIES TO RETROFIT APPLICATIONS. IF YOU ARE NOT RETROFITTING PLEASE GO TO STEP 3. If flashing cannot be pulled over the pipe due to cowl or other obstruction, cut down seam of flashing and wrap around pipe. Once fitted around pipe apply bead of sealant down mating edges of seam and crimp together using the VSRFC retrofit clips. This joint should be on down side of the pipe. VSRFC retrofit clips Cutting the seam A retrofit installation VSRFC Retrofit Clips Product Description Colour Pack Code Quantity VSRFC Retrofit Clip Silver 50 3. Use water as lubricant when sliding flashing down pipe. Aluminium base should be formed by hand around any profile or contours of sheet material. The quantity of VSRFC clips each AD Series pipe flashing requires for retrofit applications is detailed in the technical information on pages 6-8. An example of this information is shown below: FOR RETROFIT APPLICATIONS ONLY Quantity of VSRFC clips required: 6 per flashing 4. Lift flashing away from sheet material and apply bead of silicone sealant to underside of flashing base. Firmly redress flashing, and fix base to sheet as shown. Apply silicone to top of rubber cone.

6 Pipe Flashing Systems for metal roofs To order AD Series: Our product codes have been formulated to make selecting the correct pipe flashing as simple as possible by providing the information required in a concise manner, showing type, material, colour and pipe diameters. Example Code: AD EB 10-90 AD Series EPDM Black Pipe Diameters 10-90mm Use the information provided ensuring the diameter of the penetration you need to seal falls comfortably within the dimensions shown (see the Pipe Flashings Product Selector Guide for metal roofs on page 11 for further assistance). Select either EPDM black or grey (cold pipes) or silicone red (hot pipes) and use the relevant product code. FOR RETROFIT APPLICATIONS ONLY, it is necessary to order the retrofit clips (product code VSRFC). The quantity of clips required per flashing is detailed for each pipe flashing. Note: For square pipes or ducts, use the following method to calculate the size of flashing required. Add up the dimensions of all four sides and divide by 3.142. Select the flashing which will comfortably accommodate the resulting dimension. There is also an AD Series pipe flashing purpose designed for square pipes 25-100mm detailed on page 8. AD Series 10mm-90mm AD Series 40mm-100mm AD EB 10-90 EPDM Black 40 C to +115 C 10-90 10-70 155 x 155 20 AD EG 10-90 EPDM Grey 40 C to +115 C 10-90 10-70 155 x 155 20 AD SR 10-90 Silicone Red 60 C to +240 C 10-90 10-70 155 x 155 20 FOR RETROFIT APPLICATIONS ONLY Quantity of VSRFC clips required: 5 per flashing AD Series 75mm-150mm AD EB 40-100 EPDM Black 40 C to +115 C 40-100 40-90 203 x 203 10 AD EG 40-100 EPDM Grey 40 C to +115 C 40-100 40-90 203 x 203 10 AD SR 40-100 Silicone Red 60 C to +240 C 40-100 40-90 203 x 203 10 FOR RETROFIT APPLICATIONS ONLY Quantity of VSRFC clips required: 5 per flashing AD Series 125mm-200mm AD EB 75-150 EPDM Black 40 C to +115 C 75-150 75-135 254 x 254 10 AD EG 75-150 EPDM Grey 40 C to +115 C 75-150 75-135 254 x 254 10 AD SR 75-150 Silicone Red 60 C to +240 C 75-150 75-135 254 x 254 10 FOR RETROFIT APPLICATIONS ONLY Quantity of VSRFC clips required: 6 per flashing AD EB 125-200 EPDM Black 40 C to +115 C 125-200 125-180 305 x 305 10 AD EG 125-200 EPDM Grey 40 C to +115 C 125-200 125-180 305 x 305 10 AD SR 125-200 Silicone Red 60 C to +240 C 125-200 125-180 305 x 305 10 FOR RETROFIT APPLICATIONS ONLY Quantity of VSRFC clips required: 6 per flashing

Pipe Flashing Systems for metal roofs 7 AD Series 145mm-250mm AD Series 195mm-300mm AD EB 145-250 EPDM Black 40 C to +115 C 145-250 145-230 356 x 356 10 AD EG 145-250 EPDM Grey 40 C to +115 C 145-250 145-230 356 x 356 10 AD SR 145-250 Silicone Red 60 C to +240 C 145-250 145-230 356 x 356 10 FOR RETROFIT APPLICATIONS ONLY Quantity of VSRFC clips required: 7 per flashing AD Series 230mm-380mm AD EB 195-300 EPDM Black 40 C to +115 C 195-300 195-250 432 x 432 5 AD EG 195-300 EPDM Grey 40 C to +115 C 195-300 195-250 432 x 432 5 AD SR 195-300 Silicone Red 60 C to +240 C 195-300 195-250 432 x 432 5 FOR RETROFIT APPLICATIONS ONLY Quantity of VSRFC clips required: 7 per flashing AD EB 230-380 EPDM Black 40 C to +115 C 230-380 230-355 540 x 597 5 AD SR 230-380 Silicone Red 60 C to +240 C 230-380 230-355 540 x 597 5 FOR RETROFIT APPLICATIONS ONLY Quantity of VSRFC clips required: 9 per flashing AD Series 315mm-500mm AD EB 315-500 EPDM Black 40 C to +115 C 315-500 315-450 650 x 720 1 AD SR 315-500 Silicone Red 60 C to +240 C 315-500 315-450 650 x 720 1 FOR RETROFIT APPLICATIONS ONLY Quantity of VSRFC clips required: 11 per flashing AD Series 400mm-750mm AD EB 400-750 EPDM Black 40 C to +115 C 400-750 400-500 965 x 995 1 AD SR 400-750 Silicone Red 60 C to +240 C 400-750 400-500 965 x 995 1 FOR RETROFIT APPLICATIONS ONLY Quantity of VSRFC clips required: 15 per flashing EPDM Black EPDM Grey Silicone Red

8 Pipe Flashing Systems for metal roofs AD Series Square Flashing The innovative AD Series Square Flashing has been specifically designed to seal square section pipe and penetrations, and shares all the other features of the AD Series, including the retrofit seam. AD Series Square Flashing 25mm-100mm Product Material Colour Temperature Square Pipe Sizes (mm) Base Pack AD EB SQ 25-100 EPDM Black 40 C to +115 C 25-100 25-75 203 x 203 10 FOR RETROFIT APPLICATIONS ONLY Quantity of VSRFC clips required: 5 per flashing AD Series Wall Flashing The AD Series Wall Flashing has a unique flat cone, designed specifically for use on flat surfaces and vertical wall cladding. This product can be used in standard or retrofit situations and has measurement lines to help guide an even cut around the cone. AD Series Wall Flashing 0mm-125mm Code Resistance Dimensions (mm) Quantity AD EB WF 0-125 EPDM Black 40 C to +115 C 0-125 203 x 203 10 FOR RETROFIT APPLICATIONS ONLY Quantity of VSRFC clips required: 4 per flashing Wall Flashing with pipe

Pipe Flashing Systems for metal roofs 9 To order MS Series: Our product codes have been formulated to make selecting the correct pipe flashing as simple as possible by providing the information required in a concise manner, showing type, material, colour and pipe diameters. Example Code: MS EB 3-25 MS Series EPDM Black Pipe Diameters 3-25mm Use the information provided ensuring the diameter of the penetration you need to seal falls comfortably within the dimensions shown (see the Pipe Flashings Product Selector Guide for metal roofs on page 11 for further assistance). Select either EPDM black (cold pipes) or silicone red (hot pipes) and use the relevant product code. MS Series 3mm-25mm MS EB 3-25 EPDM Black 40 C to +115 C 3-25 3-20 75 x 75 20 MS SR 3-25 Silicone Red 60 C to +240 C 3-25 3-20 75 x 75 20 This product is especially suited for solar applications and its unique features are highlighted on pages 20-21 MS Series 5mm-50mm MS EB 5-50 EPDM Black 40 C to +115 C 5-50 5-45 115 x 115 20 MS SR 5-50 Silicone Red 60 C to +240 C 5-50 5-45 115 x 115 20 This product is especially suited for solar applications and its unique features are highlighted on pages 20-21 MS Series 45mm-90mm MS EB 45-90 EPDM Black 40 C to +115 C 45-90 45-80 155 x 155 20 MS SR 45-90 Silicone Red 60 C to +240 C 45-90 45-80 155 x 155 20 Pipe Flashing Systems for solar systems see pages 20-21

10 Pipe Flashing Systems for metal roofs Fixing Kits V-SEAL fixing kits have been specifically designed to simplify the installation of pipe flashings. The components included in the fixing kits provide the materials required to carry out installation on metal, plastic or fibre cement roofing and cladding materials. Each fixing kit contains: Fitting instructions clearly setting out the steps for installation. Hooked blade trimming knife designed for safe, easy cutting of sleeve. Silicone sealant to seal between the roof material and the pipe flashing. HSS drill bit to drill a pilot hole through the pipe flashing and roof material prior to fixing. Washered fasteners to firmly fix the pipe flashing to the roof material. Hexagon colour caps to cover the fastener heads and complete the aesthetic appearance. VSFK-S Product Code Contents VSFK-S 12 washered fasteners 80ml silicone sealant 12 hexagon colour caps Hooked blade trimming knife HSS drill bit Fitting instructions VSFK-L Product Code Contents VSFK-L 30 washered fasteners 300ml silicone sealant 30 hexagon colour caps Hooked blade trimming knife HSS drill bit Fitting instructions The information below, details the fixing kit(s) required to complete the installation of MS Series and AD Series pipe flashings. MS Series 3mm-25mm MS Series 5mm-50mm MS Series 45mm-90mm AD Series Square Flashing AD Series Wall Flashing AD Series 10mm-90mm AD Series 40mm-100mm 1 x VSFK-S 1 x VSFK-S 1 x VSFK-S 1 x VSFK-S 1 x VSFK-S 1 x VSFK-S 1 x VSFK-S AD Series 75mm-150mm AD Series 125mm-200mm AD Series 145mm-250mm AD Series 195mm-300mm AD Series 230mm-380mm AD Series 315mm-500mm AD Series 400mm-750mm 1 x VSFK-S 1 x VSFK-S 1 x VSFK-L 1 x VSFK-L 1 x VSFK-L 1 x VSFK-L 2 x VSFK-L

Pipe Flashing Systems for metal roofs 11 Pipe Flashings Product Selector Guide For metal roofs Suitable for 0-25 roof pitches Suitable for 0-45 roof pitches Product MS Series AD Series Pipe Diameter 3-25 5-50 45-90 10-90 40-100 75-150 125-200 145-250 195-300 230-380 315-500 400-750 3 mm - - - - - - - - - - - 5 mm - - - - - - - - - - 10 mm - - - - - - - - - 15 mm - - - - - - - - - 20 mm - - - - - - - - - 25 mm - - - - - - - - - 30 mm - - - - - - - - - - 40 mm - - - - - - - - - 50 mm - - - - - - - - 65 mm - - - - - - - - - 80 mm - - - - - - - - 90 mm - - - - - - - - 100 mm - - - - - - - - - - 125 mm - - - - - - - - - - 150 mm - - - - - - - - - 175 mm - - - - - - - - - - 200 mm - - - - - - - - - 225 mm - - - - - - - - - - 250 mm - - - - - - - - - 275 mm - - - - - - - - - - 300 mm - - - - - - - - - - 325 mm - - - - - - - - - - 350 mm - - - - - - - - - - 375 mm - - - - - - - - - - 400 mm - - - - - - - - - - 425 mm - - - - - - - - - - 450 mm - - - - - - - - - - 475 mm - - - - - - - - - - 500 mm - - - - - - - - - - 525 mm - - - - - - - - - - - 550 mm - - - - - - - - - - - 575 mm - - - - - - - - - - - 600 mm - - - - - - - - - - - 625 mm - - - - - - - - - - - 650 mm - - - - - - - - - - - 675 mm - - - - - - - - - - - 700 mm - - - - - - - - - - - 725 mm - - - - - - - - - - - 750 mm - - - - - - - - - - -

12 Pipe Flashing Systems for metal roofs Stripflash Stripflash is ideal for applications on large ducting, pipework, flues and awkward flashing details. Stripflash is a roll of flexible TPE rubber strip, which can be cut or joined to allow for use in numerous situations, solving problems where standard pipe flashings cannot be used. The edges of Stripflash contain an expanding aluminium strip enclosed by the TPE rubber. These strips allow the flashing to be formed to the shape of most roof sheet profiles. Each roll of Stripflash is supplied in a box complete with detailed fixing instructions and an aluminium joining strip. Stripflash is available in widths of 235mm or 450mm, with roll lengths and further information detailed below. Stripflash Product Material Colour Temperature Roll Dimensions Pack Code Resistance (width x length) Quantity SF TG 235 x 10 TPE Grey 30 C to +115 C 235mm x 10m 1 SF TG 450 x 15 TPE Grey 30 C to +115 C 450mm x 15m 1 Stripflash is ideally fitted using our fixing kits (product code VSFK-L) The number of kits required will vary according to the application

Pipe Flashing Systems for metal roofs 13 Expansion Joint Expansion Joint has been designed specifically for installation as an expansion joint for industrial box gutters. It can also be used to seal and repair existing gutter joints, without the joints needing to be opened, or the gutter needing to be lifted or removed. Manufactured from black EPDM rubber, with aluminium fixing strips, it is flexible, durable and waterproof, UV and air pollution resistant. Expansion Joint is available in widths of 145mm or 200mm and is supplied in 5 metre long rolls. The product is simply cut to length and formed by hand to the required shape, then dressed down onto a generous bead of silicone sealant and fixed with suitable rivets or self-drilling screws. Expansion Joint Product Material Colour Temperature Roll Dimensions Expansion Pack Code Resistance (width x length) Range (mm) Quantity EJ EB 145 x 5 EPDM Black 40 C to +115 C 145mm x 5m 145 to 175 1 EJ EB 200 x 5 EPDM Black 40 C to +115 C 200mm x 5m 200 to 250 1 Typical expansion overlap joint cross section Silicone Flexible aluminium Expansion and contraction Rivet or self-drilling screw

14 Pipe Flashing Systems for slate and tiled roofs Pipe Flashing Systems For slate and tiled roofs V-SEAL pipe flashing systems are purpose designed to provide a flexible, durable, weatherproof seal where penetrations pass through roof slates and tiles. These one piece roof flashings have a rubber cone, with a lead or aluminium base. They are supplied ready to install and eliminate the on-site fabrication required when installing a traditional lead slate. VL Series (pages 14-15) Lead base pipe flashings with rubber cone for cable and pipe diameters from 5mm to 280mm. VA Series (pages 16-17) Aluminium base pipe flashings with rubber cone for cable and pipe diameters from 5mm to 450mm. Providing solutions by design VL Series Cone Base Base The large rectangular lead base is malleable and simply formed to match the profile of roof slates and tiles. The large size of base also offers excellent coverage and provides ample working material for dressing over the tiles around the penetration. With the exception of one size, the VL Series are manufactured using Acrylead which is a unique, baked, acrylic primer coating for lead sheet. This Acrylead finish ensures safe handling and inhibits water coming into contact with lead and its oxides, which helps prevent lead run off staining the roof and entering ground water systems. Cone Each rubber cone suits a wide range of pipe sizes and roof pitches. This is a major advantage when compared with traditional lead slates that have to be fabricated to suit specific dimensions and roof angles. The pipe diameters are marked on the ribbed measurement lines, providing easy identification of size ranges and helping to guide an even cut around the cone. The flexibility of the cone allows the pipe flashing to be installed on roofs of varying pitches and also accommodates expansion, contraction and building movement, whilst maintaining a weatherproof seal. Materials VL Series lead base pipe flashings are available with cones in EPDM (for cold pipes) and silicone (for high temperature pipes). These materials are of the highest quality and are resistant to ozone and ultra violet light. The manufacturers state that the flashings have a 20 year product replacement warranty against faulty manufacture or materials. Ethylene Propylene Diene Monomer (EPDM) Rubber: Temperature range 40 C to +115 C. Silicone Rubber: Temperature range 60 C to +240 C. Lead Base: 1.1mm thick.

Pipe Flashing Systems for slate and tiled roofs 15 To order VL Series: Our product codes have been formulated to make selecting the correct pipe flashing as simple as possible by providing the information required in a concise manner, showing type, cone material, colour and pipe diameters. Example Code: VL EB 45-90 VL Series EPDM Black Pipe Diameters 45-90mm Use the information provided ensuring the pipe diameter of the penetration you need to seal falls comfortably within the dimensions shown (see the Pipe Flashings Product Selector Guide for slate and tiled roofs on page 19 for further assistance). Select either EPDM (cold pipes) or silicone (hot pipes) and use the relevant product code. VL Series 5mm-50mm TWIN PACK 2 x lead base flashings in one pack VL Series 5mm-50mm DUO 2 x cones on lead base VL SB 5-50 Silicone Black 60 C to +240 C 5-50 5-40 Acrylead 410 x 490 2 TWIN PACK This product is especially suited for solar applications and its unique features are highlighted on pages 20-21 To ensure ease of handling and product integrity, this product comes packed with two flashings in one carton. VL Series 45mm-90mm VL SB 5-50 Silicone Black 60 C to +240 C 5-50 5-40 Acrylead 450 x 600 1 DUO This product is especially suited for solar applications and its unique features are highlighted on pages 20-21 VL EB 45-90 EPDM Black 40 C to +115 C 45-90 45-75 Acrylead 450 x 600 5 VL SR 45-90 Silicone Red 60 C to +240 C 45-90 45-75 Acrylead 450 x 600 5 VL Series 100mm-150mm VL EB 100-150 EPDM Black 40 C to +115 C 100-150 100-115 Acrylead 450 x 600 5 VL SR 100-150 Silicone Red 60 C to +240 C 100-150 100-115 Acrylead 450 x 600 5 VL Series 180mm-255mm VL EB 180-255 EPDM Black 40 C to +115 C 180-255 180-200 Natural lead 600 x 700 1 VL Series 150mm-280mm VL EB 150-280 EPDM Black 40 C to +115 C 150-280 150-255 Acrylead 600 x 850 1 VL SR 150-280 Silicone Red 60 C to +240 C 150-280 150-255 Acrylead 600 x 850 1

16 Pipe Flashing Systems for slate and tiled roofs Providing solutions by design VA Series Base Base The large rectangular aluminium base is malleable and simply formed to match the profile of roof slates and tiles. The large size of base also offers excellent coverage and provides ample working material for dressing over the tiles around the penetration. A soft grade of aluminium has been carefully selected to ensure optimum workability and ease of installation. Cone Cone Each rubber cone suits a wide range of pipe sizes and roof pitches. The pipe diameters are marked on the ribbed measurement lines, providing easy identification of size ranges and helping to guide an even cut around the cone. The flexibility of the cone allows the pipe flashing to be installed on roofs of varying pitches and also accommodates expansion, contraction and building movement, whilst maintaining a weatherproof seal. Materials VA Series aluminium base pipe flashings are available with cones in EPDM (for cold pipes) and silicone (for high temperature pipes). These materials are of the highest quality and are resistant to ozone and ultra violet light. The manufacturers state that the flashings have a 20 year product replacement warranty against faulty manufacture or materials. Ethylene Propylene Diene Monomer (EPDM) Rubber: Temperature range 40 C to +115 C. Silicone Rubber: Temperature range 60 C to +240 C. Aluminium Base: Grade B1200-0, 1mm thick. To order VA Series: Our product codes have been formulated to make selecting the correct pipe flashing as simple as possible by providing the information required in a concise manner, showing type, cone material, colour and pipe diameters. Example Code: VA EB 45-90 VA Series EPDM Black Pipe Diameters 45-90mm Use the information provided ensuring the pipe diameter of the penetration you need to seal falls comfortably within the dimensions shown (see the Pipe Flashings Product Selector Guide for slate and tiled roofs on page 19 for further assistance). Select either EPDM (cold pipes) or silicone (hot pipes) and use the relevant product code. VA Series 5mm-50mm VA SB 5-50 Silicone Black 60 C to +240 C 5-50 5-40 450 x 600 5 This product is especially suited for solar applications and its unique features are highlighted on pages 20-21 VA Series 5mm-50mm DUO 2 x cones on aluminium base VA SB 5-50 Silicone Black 60 C to +240 C 5-50 5-40 450 x 600 5 DUO This product is especially suited for solar applications and its unique features are highlighted on pages 20-21

Pipe Flashing Systems for slate and tiled roofs 17 VA Series 45mm-90mm VA EB 45-90 EPDM Black 40 C to +115 C 45-90 45-75 450 x 600 5 VA SR 45-90 Silicone Red 60 C to +240 C 45-90 45-75 450 x 600 5 VA Series 50mm-170mm VA EB 50-170 EPDM Black 40 C to +115 C 50-170 50-140 450 x 600 5 VA SR 50-170 Silicone Red 60 C to +240 C 50-170 50-140 450 x 600 5 VA Series 100mm-225mm Code Resistance 0-45 Pitch 0-60 Pitch Dimensions (mm) Quantity VA EB 100-225 EPDM Black 40 C to +115 C 100-225 100-150 500 x 600 5 VA SR 100-225 Silicone Red 60 C to +240 C 100-225 100-150 500 x 600 5 VA Series 180mm-255mm VA EB 180-255 EPDM Black 40 C to +115 C 180-255 180-200 600 x 800 5 VA SR 180-255 Silicone Red 60 C to +240 C 180-255 180-200 600 x 800 5 VA Series 180mm-350mm VA EB 180-350 EPDM Black 40 C to +115 C 180-350 180-280 600 x 800 5 VA SR 180-350 Silicone Red 60 C to +240 C 180-350 180-280 600 x 800 5 VA Series 300mm-450mm VA EB 300-450 EPDM Black 40 C to +115 C 300-450 300-450 956 x 956 5 Silicone Black EPDM Black Silicone Red

18 Pipe Flashing Systems for slate and tiled roofs V-SEAL Pipe Flashings For slate and tiled roofs Installation instructions 1. Cut rubber cone to size along marked measurement lines using sharp pair of scissors or knife. Hole size of cone should be cut minimum 15mm smaller than outside diameter of pipe. 2. Use water as lubricant when sliding flashing down pipe. 3. Form an anti-capillary fold at the top of the base as shown. 4. Place flashing under the top tiles. 5. Hand form base all around and cut and form holding tabs as shown.

Pipe Flashing Systems for slate and tiled roofs 19 Pipe Flashings Product Selector Guide For slate and tiled roofs Suitable for 0-25 roof pitches Suitable for 0-45 roof pitches Suitable for 0-60 roof pitches Product VL Series VA Series Pipe Diameter 5-50 45-90 100-150 180-255 150-280 5-50 45-90 100-165 100-225 180-255 180-350 300-450 5 mm - - - - - - - - - - 10 mm - - - - - - - - - - 15 mm - - - - - - - - - - 20 mm - - - - - - - - - - 25 mm - - - - - - - - - - 30 mm - - - - - - - - - - 40 mm - - - - - - - - - - 50 mm - - - - - - - - 65 mm - - - - - - - - - - 80 mm - - - - - - - - - - 90 mm - - - - - - - - - - 100 mm - - - - - - - - - 125 mm - - - - - - - - - 150 mm - - - - - - - - 175 mm - - - - - - - 200 mm - - - - - - - 225 mm - - - - - - - 250 mm - - - - - - - - 275 mm - - - - - - - - - - 300 mm - - - - - - - - - - 325 mm - - - - - - - - - - 350 mm - - - - - - - - - - 375 mm - - - - - - - - - - - 400 mm - - - - - - - - - - - 425 mm - - - - - - - - - - - 450 mm - - - - - - - - - - - VL Series VA Series

20 Pipe Flashing Systems for solar systems Pipe Flashing Systems For solar systems Pipe flashings are a vital component required in the installation of roof mounted solar thermal and solar PV (photovoltaic) systems, as they provide a flexible, durable, weatherproof seal where solar pipework and sensor cabling pass through the roof. V-SEAL pipe flashings have been carefully designed taking into account input and requests from the experts in the solar market to provide a comprehensive solution for this important application. V-SEAL solar pipe flashings for slate and tiled roofs Cable entry points The BLACK SILICONE cone is unique to the V-SEAL pipe flashings range. It has been specifically developed to meet the requirements of solar experts and building owners who are looking for aesthetic appearance, without compromise on quality. The BLACK SILICONE replaces the red silicone normally associated with these products and provides excellent temperature resistance of 60 C to +240 C. This flexible rubber cone suits pipe diameters from 5mm to 50mm, enabling it to seal around plain pipework or insulated pipework on a variety of roof pitches. Another feature specifically designed for the solar market is the two cable entry points, for sealing around any cabling and temperature sensor wiring. The cones are made from materials of highest quality, are resistant to ozone and UV light and come with a 20 year product replacement warranty from the manufacturers. V-SEAL pipe flashings provide professional fit and forget solutions for total peace of mind. VL Series are manufactured using Acrylead which is a unique, baked, acrylic primer coating for lead sheet. This Acrylead finish ensures safe handling and inhibits water coming into contact with lead and its oxides, which helps prevent lead run off staining the roof and entering ground water systems. The BLACK SILICONE cone is fitted to either an acrylead or aluminium base and is available in two different configurations: Single cone for installations with flow and return pipework passing through the roof on either side of the solar panel. 2 pipe flashings required per installation. Duo cone for installations with flow and return pipework passing through the roof at the same side of the solar panel. 1 pipe flashing required per installation.

Pipe Flashing Systems for solar systems 21 The following two products are part of the V-SEAL VL Series and are also detailed on page 15: VL Series 5mm-50mm TWIN PACK 2 x lead base flashings in one pack VL Series 5mm-50mm DUO 2 x cones on lead base VL SB 5-50 Silicone Black 60 C to +240 C 5-50 5-40 Acrylead 410 x 490 2 TWIN PACK Solar system installations often require a pipe flashing for the flow and return pipework on either side of the solar panel. To ensure ease of handling and product integrity, this product comes packed with two flashings in one carton. VL SB 5-50 Silicone Black 60 C to +240 C 5-50 5-40 Acrylead 450 x 600 1 DUO The following two products are part of the V-SEAL VA Series and are also detailed on page 16: VA Series 5mm-50mm VA SB 5-50 Silicone Black 60 C to +240 C 5-50 5-40 450 x 600 5 VA Series 5mm-50mm DUO 2 x cones on aluminium base VA SB 5-50 Silicone Black 60 C to +240 C 5-50 5-40 450 x 600 5 DUO V-SEAL solar pipe flashings for metal roofs The following two products are part of the V-SEAL MS Series and are also detailed on page 9: MS Series 3mm-25mm MS EB 3-25 EPDM Black 40 C to +115 C 3-25 3-20 75 x 75 20 MS SR 3-25 Silicone Red 60 C to +240 C 3-25 3-20 75 x 75 20 MS Series 5mm-50mm MS EB 5-50 EPDM Black 40 C to +115 C 5-50 5-45 115 x 115 20 MS SR 5-50 Silicone Red 60 C to +240 C 5-50 5-45 115 x 115 20

22 Pipe Flashing Systems for flat roofs Pipe Flashing Systems For flat roofs V-SEAL pipe flashings are specifically designed for use with flat roofing systems. They provide a durable, flexible, weatherproof seal around pipes, vents and other penetrations that pass through bituminous or PVC and TPO roofing membranes. FR Series Felt Roofseal pipe flashings for pipe diameters from 0mm to 830mm (pages 22-24). RFR Series Felt Roofseal pipe flashings for use in retrofit applications for pipe diameters from 19mm to 250mm (page 25). MR Series Pipe flashings for use with PVC, TPO and other types of membranes, for pipe diameters from 20mm to 125mm (page 26). Providing solutions by design FR Series Sleeve Base Base The large circular base is uniquely designed with concentric rectangular ribs. This ensures the best possible adhesion of the roof system to the pipe flashing. Sleeve Each pipe flashing suits more than one pipe diameter and is Ribs on base provide excellent adhesion to bitumen simply cut to the required size as needed. Each step has the pipe diameters marked on it for easy identification of pipe sizes and helps guide an even cut around the sleeve. The stepped configuration also ensures good surface contact with the pipe and each pipe flashing is supplied with a stainless steel screw clamp to provide a tight seal. Each size of pipe flashing maintains an upstand of approximately 150mm, in accordance with recommended flat roofing good practices. The flexibility of the sleeve allows for expansion, contraction and building movement whilst maintaining a weatherproof seal. Materials The pipe flashings are made from EPDM and are resistant to acids, ozone and ultra violet light. The manufacturer gives a 10 year warranty for the EPDM material. Ethylene Propylene Diene Monomer (EPDM Rubber): Temperature range 30 C to +90 C. (Short term fluctuations between 50 C and +120 C are permissible). Installation temperatures for liquid bitumen can be up to 240 C. Stainless steel pipe clamp.

Pipe Flashing Systems for flat roofs 23 To order FR Series: Our product codes have been formulated to make selecting the correct pipe flashing as simple as possible by providing the information required in a concise manner, showing type, material, colour and pipe diameters. Example Code: FR EB 0-40 FR Series EPDM Black Pipe Diameters 0-40mm Use the information provided ensuring the pipe diameter of the penetration you need to seal falls comfortably within the dimensions shown. Please note that these flashings are made from flexible EPDM rubber and will stretch to accommodate the pipe diameters that are between the sizes listed. FR Series 0mm-40mm FR EB 0-40 EPDM Black 30 C to +90 C 0-40 425 20 50mm-60mm FR EB 50-60 EPDM Black 30 C to +90 C 50-60 462 20 75mm-90mm FR EB 75-90 EPDM Black 30 C to +90 C 75-90 492 20 110mm-125mm FR EB 110-125 EPDM Black 30 C to +90 C 110-125 527 20 130mm-140mm FR EB 130-140 EPDM Black 30 C to +90 C 130-140 540 20 150mm-175mm FR EB 150-175 EPDM Black 30 C to +90 C 150-175 576 10 200mm-250mm FR EB 200-250 EPDM Black 30 C to +90 C 200-250 637 10 275mm-325mm FR EB 275-325 EPDM Black 30 C to +90 C 275-325 712 5 350mm-400mm FR EB 350-400 EPDM Black 30 C to +90 C 350-400 787 5 490mm-530mm FR EB 490-530 EPDM Black 30 C to +90 C 490-530 800 1 590mm-630mm FR EB 590-630 EPDM Black 30 C to +90 C 590-630 900 1 690mm-730mm FR EB 690-730 EPDM Black 30 C to +90 C 690-730 1000 1 790mm-830mm FR EB 790-830 EPDM Black 30 C to +90 C 790-830 1100 1

24 Pipe Flashing Systems for flat roofs FR Series Square Flashings The FR Series Square flashings are purpose designed to seal square section pipes and penetrations through felt roofs. They share all the other features of the FR Series and also require a special Square clamp to suit the size of pipe (please see information below). FR Series Square Flashing 40mm-70mm 40mm-70mm Product Material Colour Temperature Square Sections Base Pack FR SQ EB 40-70 EPDM Black 30 C to +90 C 40 x 40 70 x 70 470 20 FR Series Square Flashing 80mm-140mm 80mm-140mm Product Material Colour Temperature Square Sections Base Pack FR SQ EB 80-140 EPDM Black 30 C to +90 C 80 x 80 140 x 140 555 20 FR Series Square Clamps Product Material Square Sections Code (mm) (mm) FR SQ CP 40 Galvanised Steel 40 x 40 FR SQ CP 50 Galvanised Steel 50 x 50 Square Clamps FR SQ CP 60 Galvanised Steel 60 x 60 FR SQ CP 70 Galvanised Steel 70 x 70 FR SQ CP 80 Galvanised Steel 80 x 80 FR SQ CP 100 Galvanised Steel 100 x 100 FR SQ CP 120 Galvanised Steel 120 x 120 FR SQ CP 140 Galvanised Steel 140 x 140 FR Series Vapourseal The FR Series Vapourseal maintains roof system integrity by sealing between the pipe and the vapour control layer. It acts as a barrier to block moisture entering the roof structure and stops damage to the roof. It also seals against air leakage which helps to meet building regulation requirements. FR Series Vapourseal 50mm 50mm FR VP EB 50 EPDM Black 30 C to +90 C 50 350 20 FR Series Vapourseal 75mm 75mm FR VP EB 75 EPDM Black 30 C to +90 C 75 375 20 FR Series Vapourseal 110mm 110mm FR VP EB 110 EPDM Black 30 C to +90 C 110 410 20

Pipe Flashing Systems for flat roofs 25 Providing solutions by design RFR Series The RFR Series is for retrofit applications, where the pipe flashing needs to be cut and wrapped around the penetration due to obstructions such as cowls, brackets or collars. The base design and materials used are exactly the same as the FR Series detailed on page 22. The sleeve also shares the same features but has an additional design characteristic which makes the products suitable for retrofit applications. The retrofit seal is already formed and contains a sealant compound which forms a weatherproof seal when the edges of the seal are joined together. The integrity of the vertical joint is maintained by securing the seam with an aluminium locking clip. Use the information provided ensuring the pipe diameter of the penetration you need to seal falls comfortably within the dimensions shown. Please note that these flashings are made from flexible EPDM rubber and will stretch to accommodate the pipe diameters that are between the sizes listed. RFR Series 19mm-90mm 19mm-90mm RFR EB 19-90 EPDM Black 30 C to +90 C 19-90 420 1 RFR Series 110mm-170mm 110mm-170mm RFR EB 110-170 EPDM Black 30 C to +90 C 110-170 510 1 RFR Series 160mm-250mm 160mm-250mm RFR EB 160-250 EPDM Black 30 C to +90 C 160-250 595 1 Installation instructions for FR Series and RFR Series Start by determining the pipe diameter. If necessary, cut the sleeve to the correct size. Dress the base layer of the felt tightly around the pipe. The base flange of the pipe flashing should always be bonded between two waterproofing layers. If a single layer membrane is being used, bond an additional piece of the waterproofing layer beneath the pipe flashing flange. This piece should be about 300mm larger that the outer diameter of the flange. Bond the base flange of the pipe flashing to the base layer. Cut an opening for the pipe in the upper layer of felt (the felt should only cover the base flange) and bond down onto the base of the pipe flashings. If required, seal between the upper layer of felt and the pipe flashing with a suitable sealing compound. Fit the stainless steel clamp.

26 Pipe Flashing Systems for flat roofs Providing solutions by design MR Series Sleeve Base MR Series pipe flashings are particularly for use with roofing membranes and are available in three different materials. EPDM for use with built up felt and mastic asphalt roof finishes. PVC for use with PVC single ply membranes. PP for use with TPO single ply membranes. Base The circular base provides a large surface area to ensure the best possible adhesion of the roof system to the pipe flashing. Sleeve Each flashing suits more than one pipe diameter and is simply cut to the required size as needed. The stepped configuration ensures good surface contact with the pipe and each flashing is supplied with a stainless steel screw clamp to provide a tight seal. The flexibility of the sleeve allows for expansion, contraction and building movement whilst maintaining a weatherproof seal. Materials Ethylene Propylene Diene Monomer (EPDM) Rubber: Temperature range 40 C to +120 C. Polyvinyl Chloride (PVC): Temperature range 25 C to +90 C. Polyolefin Polypropylene (PP): Temperature range 40 C to +120 C. The manufacturer gives a 10 year warranty for the materials. To order MR Series: Our product codes have been formulated to make selecting the correct pipe flashing as simple as possible by providing the information required in a concise manner, showing type, material, colour and pipe diameters. Example Code: MR EB 34-90 MR Series EPDM Black Pipe Diameters 34-90mm Use the information provided ensuring the pipe diameter of the penetration you need to seal corresponds with the dimensions shown. MR Series 20mm MR Series 34mm-90mm MR EB 20 EPDM Black 40 C to +120 C 20 155 25 MR PG 20 PVC Grey 25 C to +90 C 20 155 25 MR TG 20 PP Grey 40 C to +120 C 20 155 25 MR EB 34-90 EPDM Black 40 C to +120 C 34, 50, 60, 75, 80, 90 340 25 MR PG 34-90 PVC Grey 25 C to +90 C 34, 50, 60, 75, 80, 90 340 25 MR TG 34-90 PP Grey 40 C to +120 C 34, 50, 60, 75, 80, 90 340 25

Pipe Flashing Systems for flat roofs 27 MR Series 75mm-125mm MR EB 75-125 EPDM Black 40 C to +120 C 75, 80, 90, 100, 110, 115, 125 365 25 MR PG 75-125 PVC Grey 25 C to +90 C 75, 80, 90, 100, 110, 115, 125 365 25 MR TG 75-125 PP Grey 40 C to +120 C 75, 80, 90, 100, 110, 115, 125 365 25 Installation instructions for MR Series with single ply membranes Start by determining the pipe diameter. If necessary, cut the sleeve to the correct size. Place the pipe flashing over the pipe and weld the base flange to the waterproofing membrane with a hot air gun or relevant adhesive. Fit the stainless steel clamp. Installation instructions for MR Series with felt roof systems see page 25.