Custom Home Design Plan # 118 By SDS-CAD Specialized Design Systems

Similar documents
Transcription:

REVISIONS SDS-CAD Specialized Design Systems P O Box 74 Mendon, Utah www.sdscad.com email: sdscad@pcu.net Residential Design BUILDING CONTRACTOR/HOME OWNER TO REVIEW AND VERIFY ALL DIMENSIONS, SPECS, AND CONNECTIONS BEFORE CONSTRUCTION BEGINS. HOME TO BE BUILT AS PER IRC 200 OR CURRENT CODE ELECTRICAL SYSTEM CODE: SEC.2701 MECHANICAL SYSTEM CODE: SEC.2801 PLUMBING SYSTEM CODE: SEC.2901 Custom Home Design Plan # 8 By SDS-CAD Specialized Design Systems Page 1 Cover Page Page 2 Main Floor Plan Page Basement Plan Page 4 Second Floor Plan Page 5 Elevation Plan Page 6 Floor and Roof Framing Plan Page 7 Whole House Sections Page 8 Cabinet & Stair Detailsl Page 9 Main Floor Electrical Page 10 Second Floor Electrical Page Basement Electrical To the best of my knowledge these plans are drawn to comply with owner's and/ or builder's specifications and any changes made on them after prints are made will be done at the owner's and / or builder's expence and responsibility. The contractor shall verify all dimensions and enclosed drawing. SDSCAD is not liable for errors once construction has begun. While every affort has been made in the preparation of this plan to avoid mistakes, the maker can not guarantee against human error. The contractor of the job must check all dimensions and other details prior to construction and be solely responsible thereafter. All calculations and member sizing should be verified for your building by a certified building official. CLIENT DRWN BY CHK'D BY JOB NO. 5/19/2005 John Davidson Note: Paper size B - x 17 if printed on D - 22 x 4 scale is 2 X of stated scale @COPYRIGHT SDSCAD Specialized Design Systems SHEET NO. 1 OF

REVISIONS DOOR SCHEDULE NUMBER QTY FLOOR SIZE DIMENSIONS DESCRIPTION D01 1 0X80X1 /8" PANEL DOOR - COLOR BRITE WHITE D02 1 1 0X80X1 /8" POCKET D0 1 1 2868 2X80X1 /8" PANEL DOOR - COLOR BRITE WHITE D04 1 1 068 6X80X1 /4" 6-PANEL D05 2 1 068 6X80X1 /4" EXT. 6-PANEL D06 1 1 068 6X80X1 /4" HINGED-GLASS D07 1 1 5068 0X80X1 /4" HINGED-GLASS D08 2 1 9080 108X96" GARAGE 2-PANEL GARGE DOOR D09 1 2 1868 20X80X1 /8" PANEL DOOR - COLOR BRITE WHITE D10 1 2 0X80" BIFOLD D 7 2 0X80X1 /8" PANEL DOOR - COLOR BRITE WHITE D12 1 2 5068 0X80" BIFOLD D1 2 2 6668 9X80" BIFOLD D14 4 0 0X80X1 /8" PANEL DOOR - COLOR BRITE WHITE WINDOW SCHEDULE NUMBER QTY FLOOR SIZE DIMENSIONS DESCRIPTION W01 2 1 1450 16"X60" SINGLE HUNG W02 1 1 6"X60" SINGLE HUNG W0 2 1 2650 0"X60" SINGLE HUNG W04 1 1 5284 62"X100" MULLED UNIT W05 2 1 040 6"X48" SINGLE HUNG W06 2 6"X60" SINGLE HUNG W07 2 1650 18"X60" FIXED GLASS W08 2 0 4040 48"X48" RIGHT SLIDING W09 2 2 2020 24"X24" 24X24 OCTAGON W10 4 2020 24"X24" 24X24 OCTAGON Residential Design 40'-6" 9'-4" 6'-6" 17'-8" '-4" 10'-10" '-6" '-6" 5'-0" '-2" 068 2'-6" 16'-6" 6'-10" MASTER BDRM 16'-1" x 22'-6" '-6" MASTER BATH 16'-1" x 9'-7" '-0" BWP Wall Single Sheet one side of wall w/ 7/16" D.S.B. Nailed 8d@6"o.c. Edge and 12" o.c. Field 8'-8" '-0" 2868 2868 '-" 9'-7" 1'-1" '-5" '-5" 16'-4" LIVING '-8" x 1'-5" 18'-10" 5'-9" 4'-6" GREAT ROOM 18'-2" x 2'-8" 1'-6" UP (2) 1 /4" x 7/8" LVL BEAM 8068 DN 5068 8" 74'-0" 2'-0" 2'-0" 2'-0" 6'-8" 2'-0" '-6" 2'-8" '-9" 12'-0" 12068 8068 1450 (2) 1 /4" x 14 LVL Beam (2) 1 /4" x 7/8" LVL BEAM 2650 2650 () 1 /4" x 7/8" LVL BEAM BWP Wall Single Sheet one side of wall w/ 7/16" D.S.B. Nailed 8d@6"o.c. Edge and 12" o.c. Field DINING '-8" x 1'-5" 068 1450 2'-0" 1'-0" '-0" '-" '-0" AC 068 040 040 8'-8" 21'-10" 10'-7" 068 Garage/House BWP Wall Single Sheet one side of wall w/ 7/16" D.S.B. Nailed 8d@6"o.c. Edge and 12" o.c. Field Cover with 5/8 Fire code sheetrock 4" Concrete with WWM over compacted gravel fill sloped to door 1" slope per 10' to garage door GARAGE 25'-9" x 25'-4" '-" 5'-0" 6'-6" Garage Door Wall Single Sheet Both sides of wall w/ 7/16" D.S.B. Nailed 8d@6"o.c. Edge and 12" o.c. Field 4'-6" (2) 1 /4" x 7/8" LVL BEAM (2) 1 /4" x 7/8" LVL BEAM 068 9080 9080 7'-0" '-6" 8'-6" 2'-6" 29'-6" 4'-0" 8'-6" Range Hoods All Bath Fans Dryer Vent FOOTING SCHEDULE HOUSE WALLS 20" x 10" Min DECKS & PORCHES 20" x 10" Min BEARING WALL 20" x 10" Min GARAGE WALL 20" x 10" Min Min 2 #4 Rebar Horizontal on undisturbed or compacted soil VENTING SCHEDULE ATTIC VENTILATION: AREA / 00 PROVIDE 1" MIN. AIR GAP AT EAVES WITH INSULATION BAFFELS TYP. AT ALL TRUSS BAYS. PROVIDE GABLE VENTS ALL GABLE ENDS. PROVIDE GALV. ROOF VENTS ON BACKSIDE OF ROOFLINE ABOVE CONDITIONED AREA. Vent Through Roof Vent to Exterior Vent to Exterior INSULATION SCHEDULE Ceilings Wall above grade Wall interior below grade R-8 Min R-19 Min R-1 Min SDS-CAD Specialized Design Systems P O Box 74 Mendon, Utah www.sdscad.com email: sdscad@pcu.net CLIENT 5/19/2005 2'-0" 2'-0" 5284 2'-0" DRWN BY CHK'D BY John Davidson 4'-6" 6'-6" 2'-6" '-0" '-6" 5'-8" '-6" 2'-10" '-0" '-6" 5'-8" '-6" '-0" 2'-6" 6'-10" 8'-6" 5'-6" '-0" 5'-6" 12'-8" 5'-10" 12'-8" 5'-6" 20'-10" 74'-0" DN 6'-0" MAIN FLOOR PLAN SCALE 1/8"=1' LIVING AREA 1928 sq ft Note: Paper size B - x 17 if printed on D - 22 x 4 scale is 2 X of stated scale @COPYRIGHT SDSCAD Specialized Design Systems JOB NO. SHEET NO. 2 OF

REVISIONS SINGLE POUR RIM JOIST INSTALLATION HD1 = HPAHD22 Simpson Hold Downs HD2 = STHD14RJ Simpson Hold Downs SEE FOOTNOTE NO.5 1/2" MIN. FROM CORNER NAILED PORTION 1 1/2" 16'-6" ONE #4 REBAR IN SHEAR CONE Simpson Strong-Tie HPAHD '-0" SINGLE POUR CORNER INSTALLATION 0" MINIMUM REBAR LENGTH ONE #4 REBAR IN SHEAR CONE 12" MINIMUM REBAR LENGTH CORNER DISTANCE FROM EDGE OF STRAP TO CORNER Simpson Strong-Tie HPAHD 18'-10" 4" CONC. SLAB 20"X10" CONC. FOOTING BEARING WALL DETAIL N.T.S. 74'-0" 12'-4" 1/2"X10" FOUNDATION BOLTS @ 24" O.C. 2- #4 REBAR CONTINUOUS All Support Posts to be 24" x 24" x 9" Minimum footing 0" Min below grade then 12" Dia Sonotube to 6" above grade '-0" 8'-0" 21'-10" GRADE % 2 MIN. SLOPE 10"X20" CONC. FOOTINGS BASEMENT WALL DETAIL N.T.S. 8" VERTICAL REBAR #4 @24 O.C. J-BAR DOWELS TO MATCH VERTICAL REBAR SPACING. EXTENDED 24" MIN. INTO FOUNDATION WALL. WITH 6" MIN. HOOK 4'-6" @2" MAX. SPACING. BOLTS SHALL BE EMBEDDED 7" MIN. 8" MIN. THICKNESS HORIZONTAL REBAR # 4 @24" O.C. W/FIRST BAR PLACED 4" ABOVE FOOTING & LAST BAR 4" BELOW TOP OF FOUNDATION WALL. 4" CONC. SLAB 4" GRAVEL COMPACTED SOIL 2- #4 REBAR CONTINUOUS FLOOR JOIST 1/4" 4X4" BASE PLATE STL. SHIMS AS REQD. CONCRETE SLAB 4-1/2"DIA ANCHOR BOLTS W/WASHERS STD. PIPE COLUMN BASE PLATE BEAM LVL SIZE & BEAM LOCATED AS SHOWN ON BUILDING SECTION STEEL COLUMN CONCRETE PAD -1/2" CONCRETE FILLED NOTE:CONC. SLAB TO BE POURED AROUND POST PRIOR TO SETTING FLOOR JOIST UNDISTURBED SOIL SET BEARING PLATE ON STIFF GROUT WOOD BEAM & COLUMN N.T.S. Can be used for bearing wall applications Concrete: 1. All slabs are to be 4" concrete over 4" gravel unless otherwise noted on the plans. 2. Concrete to be ACI 01-66, Type II cement, 2500 psi at 28 days, 5" maximum slump.. Reinforcing to be ASTM A615-Bars with Fy=60 ksi lamp 0 diameter minimum at splices or weld per ACI Std. 4. Concrete design based on Fc 2000 psf, Fc 2500 psi for quality only. 5. Anchor bolts shall be A-07 embedded 7" minimum into concrete or masonry grout. Residential Design SDS-CAD Specialized Design Systems P O Box 74 Mendon, Utah www.sdscad.com email: sdscad@pcu.net 6'-0" Bearing Wall 6'-2" END LENGTH CUT 8'-6" '-6" 6'-0" 4'-0" 1'-6" 4'-0" Window Well Window Well 4040 4040 Bearing Wall UP Provide Proper Fresh Air Venting for # of Gas Appliances Floor Drain Required Flue through Roof Required if Direct Vent Appieces are not installed WH WH FAU/AC Water Softner GARAGE 25'-8" x 25'-4" 8'-6" '-6" LENGTH BRACED WALL PANEL 4X8 SHT. ON FOUNDATION. NAIL W/8d NAILS @6" O.C. CLEAR SPAN EDGES @12" O.C. IN FIELD. NAIL BOTTOM TO SILL PLATE. END LENGTH Provide minimum 1" end distance Equal number of specified nails in each end Simpson Strong-Tie ALTERNATE BRACE WALL PANELS CS16 PROVIDE (2) STRAPS FOR B.W.P. BRACED WALLS AND ALT BRACED WALL OPTIONS Brace all exterior walls and cross-stud partitions at each end of building and at least every 25' of length by one of the following: a. Simpson WB 126 wall bracing with -16d nails at each end and 1-8d nails at each stud. b. Plywood sheathing of a minimum thickness of /8 inch. c. Continuous bracing from floor to floor Simpson HPAHD strap location marker CLIENT DRWN BY CHK'D BY 5/19/2005 John Davidson 2'-0" 16'-6" 18'-10" 12'-4" 26'-4" 74'-0" 2'-0" BASEMENT PLAN SCALE 1/8"=1' JOB NO. LIVING AREA 1895 sq ft Note: Paper size B - x 17 if printed on D - 22 x 4 scale is 2 X of stated scale @COPYRIGHT SDSCAD Specialized Design Systems SHEET NO. OF

REVISIONS SDS-CAD Specialized Design Systems Residential Design 8'-6" '-6" 2020 16'-6" BWP Wall Single Sheet one side of wall w/ 7/16" D.S.B. Nailed 8d@6"o.c. Edge and 12" o.c. Field Developed with LL40 / DL10 Attic Trusses ATTIC 12'-10" x 2'-6" Possible Furnace Location if two furnaces required '-0" 2'-4" 6'-6" '-6" BATH 6'-5" x 9'-6" '-" 1868 5068 '-0" 1'-8" BEDROOM '-8" x 10'-" 8'-0" OPEN BELOW 18'-0" x 2'-8" 6'-0" DN 1'-2" '-" BWP Wall Single Sheet one side of wall w/ 7/16" D.S.B. Nailed 8d@6"o.c. Edge and 12" o.c. Field HALL 5'-" x 9'-5" 6" Min Railing 5'-6" 74'-0" 8'-2" '-" BEDROOM '-9" x 12'-1" 2'-" 6668 8'-2" 5'-2" BATH 8'-1" x 5'-1" '-" 6668 6'-2" 12'-2" '-0" '-0" 26'-4" ATTIC 25'-8" x 7'-2" Wall location may vary depending on engineered truss design. Developed with LL40 / DL10 Attic Trusses BONUS ROOM 25'-8" x 17'-5" Wall location may vary depending on engineered truss design. ATTIC 25'-8" x 7'-2" 2020 8'-0" 17'-6" 8'-0" 6'-6" ENGINEERED TRUSSES 24" O.C. R-8 CEILING INSULATION 1/2" DRYWALL CEILING DOUBLE 2" X 6" TOP PLATE 2" X 6" BOTTOM PLATE /4" T & G PLYWOOD FLOORING RIM JOIST INSULATION DOUBLE 2" X 6" TOP PLATE 2" X 6" BOTTOM PLATE /4" T & G PLYWOOD FLOORING RIM JOIST INSULATION 2" X 4" TOP PLATE GRADE 2x4" WALL STUDS 16" O.C. 1/2" INSULATION VAPOR BARRIER 1/2" DRYWALL 12 8 ASPHALT SHINGELS FELT PAPER ICE & WATER SHIELD 5/8" MIN EXTERIOR SHEATHING TRUSSES 24" 0.C. 1" CONT. AIR SPACE DRIP EDGE 1" X 6" FASCIA 2" X 6" SUB FASCIA VENTED SOFFIT 2" X 2" SOFFIT NAILER 4" LAP SIDING HOUSE WRAP (BUILDING PAPER) 1/2" EXTERIOR SHEATHING 5 1/2" WALL STUDS 16" O.C. 5 1/2" WALL INSULATION VAPOR BARRIER 1/2" DRYWALL 1 /4" X 7/8" I-JOIST 16" O.C. 2" X 10" RIM JOIST 1/2" EXTERIOR SHEATHING 4" LAP SIDING HOUSE WRAP (BUILDING PAPER) 1/2" EXTERIOR SHEATHING 5 1/2" WALL STUDS 16" O.C. 5 1/2" WALL INSULATION VAPOR BARRIER 1/2" DRYWALL 1 /4" X 7/8" I-JOIST 16" O.C. 2" X 7/8" RIM JOIST 1/2" EXTERIOR SHEATHING 2" X 6" TREATED SILL PLATE SILL SEAL 1/2" ANCHOR BOLTS 6' O.C. P O Box 74 Mendon, Utah www.sdscad.com email: sdscad@pcu.net 2'-0" 1650 2'-0" 1650 1650 2'-0" 2" X 4" TREATED BOTTOM PLATE 4" CONCRETE FLOOR W/ WIRE MESH 8" FULL CONCRETE W/ VERTICAL REINF (AS REQUIRED) DAMP PROOFING (TO GRADE) 10" X 20" CONT. CONCRETE FOOTING RE-BAR (2) '-2" 6'-4" '-2" 1'-2"1'-9"1'-9"1'-2" '-2" 6'-4" '-2" 16'-6" 12'-8" 5'-10" 12'-8" 26'-4" 74'-0" VAPOR BARRIER 4" GRAVEL BASE 4" DRAIN TILE TO DAYLIGHT OR MECHANICAL PUMP 12" GRAVEL FILL CLIENT DRWN BY 5/19/2005 John Davidson LIVING AREA 8 sq ft Typical 2 Story Section Section 8 CHK'D BY SECOND FLOOR PLAN SCALE 1/8"=1' Note: Paper size B - x 17 if printed on D - 22 x 4 scale is 2 X of stated scale @COPYRIGHT SDSCAD Specialized Design Systems JOB NO. SHEET NO. 4 OF

8/12 PITCH /12 PITCH Residential Design LEFT ELEVATION SCALE 1/16"=1' REAR ELEVATION SCALE 1/16"=1' RIGHT ELEVATION SCALE 1/16"=1' SDS-CAD Specialized Design Systems P O Box 74 Mendon, Utah www.sdscad.com email: sdscad@pcu.net '-0" 9'-0" '-2" 9'-10" 12/12 PITCH ARCHITECTURAL ASHPHALT SHINGLES 1'-0" Siding CLIENT DRWN BY 5/19/2005 John Davidson CHK'D BY 9'-0" 1'-0" REVISIONS FRONT ELEVATION SCALE 1/8"=1' Note: Paper size B - x 17 if printed on D - 22 x 4 scale is 2 X of stated scale @COPYRIGHT SDSCAD Specialized Design Systems JOB NO. SHEET NO. 5 OF

REVISIONS 4040 4040 Roof Framing: 1. Fascia to be 2"x Douglas Fir. 2. For soffit size see details.. For spans and dimensions refer to floor plans. 4. Trusses are to be an approved truss design from the truss manufacture's engineer. Install as per engineers specs 5. Use Simpson H-1 hurricane anchors at each truss or rafter to wall connection. 6. Solid blocking required between joists, rafters, and trusses over all bearing walls. Such blocking shall be 1 ½" minimum thickness and full depth of joists, rafters, or trusses. 7. Minimum header sizes shall be according to the header size table unless otherwise noted. 8. Basis of design roof live/snow load of 7 psf, and roof dead load of 15 psf. 9. Plywood roof decking to be Min ½" thick, 24/0, CDX or 5/8 wafer. MAIN FLOOR FRAMING SCALE 1/16"=1' 2x12 joists 16" OC UP Bearing Wall GARAGE 25'-8" x 25'-4" 2ND FLOOR FRAMING SCALE 1/16"=1' UP DN ROOF FRAMING 8/12 PITCH Attic Truss 8/12 PITCH SCALE 1/16"=1' /12 Pitch 8/12 PITCH 8/12 PITCH 8/12 PITCH Attic Truss 8/12 PITCH Residential Design SDS-CAD Specialized Design Systems P O Box 74 Mendon, Utah www.sdscad.com email: sdscad@pcu.net 12/12 PITCH 12/12 PITCH LIVING AREA 7/8" I Joists 16" O.C. DN /12 Pitch SEE GENERAL SPECS AND NOTES FOR FRAMING DETAILS PRE-ENGINEERED ENERGY TRUSSES AS SUPPLIED BY TRUSS MANUFACTURER 1. Trusses to be 24" O.C. 2. Attic access min 22 1/2" x 0" were most convenient. For all areas greater than 0". Vaulted ceiling over family and living room area using vaulted scizzor trusses where possible. 4. Install all trusses as per truss manufacturer installation guidelines. 5. Attic Trusses 8/12 Pitch over garage area for bonus room 6. 8/12 Pitch for main house 7. /12 Pitch for Porches Note: Paper size B - x 17 if printed on D - 22 x 4 scale is 2 X of stated scale @COPYRIGHT SDSCAD Specialized Design Systems CLIENT DRWN BY CHK'D BY JOB NO. SHEET NO. 5/19/2005 John Davidson 6 OF

REVISIONS SDS-CAD Specialized Design Systems Residential Design General framing: (Douglas Fir) 1. Minimum header sizes shall be according to the following table unless otherwise noted. Header sizes (single story construction) 2'-0" to 4'-0" Span 2-2x4's 4' + to 6'-0" Span 2-2x6's 6' + to 8'-0" Span 2-2x8's 8' + to 10'-0" Span 2-2x10's 10' + to 12'-0" Span 2-2x12's Header sizes (two story construction) 2'-0" to '-0" Span 2-2x4's ' + to 5'-0" Span 2-2x6's 5' + to 7'-0" Span 2-2x8's 7' + to 8'-0" Span 2-2x10's 2. Brace all exterior walls and cross-stud partitions at each end of building and at least every 25' of length by one of the following: a. Simpson WB 126 wall bracing with -16d nails at each end and 1-8d nails at each stud. b. Plywood sheathing of a minimum thickness of /8 inch.. Fire stopping: a. Fireblock stud spaces over 10' in height, furred spaces, soffits, drop ceilings, cove ceilings, stair stringers at top and bottom of run, bearing walls and ceiling joist lines, etc. Firestopping shall consist of 2" nominal lumber. b. Firestop openings around vents, pipes, ducts, chimneys, and fireplaces at ceiling and floor levels with approved noncombustible materials. 4. CDX plywood is not approved where exposed to weather, i.e., roof overhangs. 5. Exterior wall framing to be 2"x6" studs at 16" o.c. Interior wall, framing at non-bearing walls to be 2"x4" studs at 24" o.c. and at bearing walls 2"x4" studs at 16" o.c. with double top plate. 6. Shear wall to be /8" CDX plywood applied horizontally. 7. All stress grade lumber shall comply with WCLA specs and bear approval stamp on all pieces in place. 8. Framing lumber shall be Douglas Fir construction grade Fb 1450 or better unless otherwise noted. 9. Nailing to be per current U.B.C. unless otherwise noted. 10. All bearing partitions shall have double top plates.. Structural glued laminated timbers to be stamped by an approved agency. 12. Use redwood or pressure treated sole plates at all exterior walls. Floor Framing: CLIENT DRWN BY CHK'D BY 5/19/2005 John Davidson P O Box 74 Mendon, Utah www.sdscad.com email: sdscad@pcu.net 1. All floor joist to be Douglas Fir #2 or T.J.I. @ 16" o.c. unless otherwise noted. 2. For spans and dimensions refer to floor plans.. Use Simpson H 2.5 hurricane anchors at each floor joist to bearing wall connection. 4. Solid blocking between joists over all bearing walls, and midspans such blocking shall be 2" minimum thickness and full depth of joists. 5. Minimum header sizes shall be according to the header size table unless otherwise noted. 6. Basis of design: floor live load of 40 psf, and floor dead load of 15 psf. 7. Floor decking to be ¾" thick T & G wafer board. 8. Joist hangers to be Simpson U210 or equal unless otherwise noted. 9. Double joists and or double blocking at all interior walls. FULL HOUSE FRAMING SECTION SCALE 1/8"=1' Note: Paper size B - x 17 if printed on D - 22 x 4 scale is 2 X of stated scale @COPYRIGHT SDSCAD Specialized Design Systems JOB NO. SHEET NO. 7 OF

REVISIONS STAIR DETAILS A 2x12 STRINGER - EACH REQUIRED B 2x6 KICK PLATE - ANCHORED TO CONCRETE WITH 1/2" EXPANSION BOLTS - ANCHORED TO FLOOR DECKING WITH 6-16d NAILS. C x9/8" PARTICLE BOARD TREAD WITH 1" MIN. NOSING D 1"x8" #2 PINE RISER E 2x6 LEDGER SECURED TO EACH STUD WITH 2-16d NAILS. F HANDRAIL/GUARDRAIL - FINAL STYLE, MATERIAL AND COLOR TO BE OWNER'S CHOICE. DESIGN TO BE PER CURRENT U.B.C.: 1. GUARDRAILS TO BE 6" HIGH MIN. 2. HANDRAILS TO BE 4" TO 8" ABOVE NOSING OF TREAD. OPEN RAILING TO HAVE INTERMEDIATE RAILS OR ORNAMENTAL PATTERN SUCH THAT A SPHERE 4" ROUND CANNOT PASS THRU. G 5/8" TYPE "X" DRYWALL REQUIRED UNDER STAIRS AND ALONG STAIR WELL WALLS. E F H A G B C STAIR DETAIL D B CABINET SCHEDULE NUMBER QTY FLOOR DIMENSIONS DESCRIPTION C01 2 1 18X12X0 " WALL CAB C02 1 1 18X24X6 " BASE CAB C0 1 1 24X12X0 " WALL CAB C04 1 1 24X24X6 " BASE CAB C05 1 1 0X24X6 " PEN BASE CAB C06 1 1 X24X6 " BASE CAB C07 1 1 X24X6 " PEN BASE CAB C08 1 1 6X12X18 " WALL CAB C09 5 1 6X12X0 " WALL CAB C10 5 1 6X24X6 " BASE CAB C 2 1 6X6X6 " CRNR BASE CAB C12 2 1 57X24X6 " BATH BASE CAB C1 1 2 X24X6 " BATH BASE CAB C14 1 2 9X24X6 " BATH BASE CAB Kitchen layout and cabinets to be chosen by homeowner/contractor basic layout for reference only. Measure after sheetrock is installed for correct sizing. Residential Design SDS-CAD Specialized Design Systems P O Box 74 Mendon, Utah www.sdscad.com email: sdscad@pcu.net STAIR SPECIFICATIONS 1. Stairs to be constructed with the following materials: 2x6 kick plate anchor to concrete with expansion type anchor bolts, 2x12 treads nosing 1 1/8" minimum, -2x12 stringers required, 2x12 blocking, ¾" wafer board risers and 2x6 ledger. 2. Handrail/Guardrails final style, material and color to be owner's choice. Design to be per code.. Guardrails to be 42" high minimum from floor. 4. Handrails to be 4"-8" above tread nosing. 5. Open railing to have intermediate rails or ornamental pattern such that a sphere 4" round cannot pass through. 6. Minimum stair requirements: maximum 8" rise, minimum 42" width, minimum 9" run, minimum head clearance 6'-8". 7. Preferred stair requirements: rise 7" to 7 ½", run " to 12", minimum head clearance 7'-0". 8. Garage entrance stairs may be concrete or wood as per contractor/homeowner PBS6 W60 W60 WR180 BD66 BD66 Cabinet Detail SCALE 1/4"=1' CBD66 PBD06 BD66 BD66 BD66 BDR186 W60 W60 W60 WR180 BLWR20 W618 Note: Paper size B - x 17 if printed on D - 22 x 4 scale is 2 X of stated scale @COPYRIGHT SDSCAD Specialized Design Systems CLIENT DRWN BY CHK'D BY JOB NO. SHEET NO. 5/19/2005 John Davidson 8 OF

REVISIONS BWP Wall Single Sheet one side of wall w/ 7/16" D.S.B. Nailed 8d@6"o.c. Edge and 12" o.c. Field MASTER BDRM 16'-1" x 22'-6" 4 SD 4 WP GREAT ROOM 18'-2" x 2'-8" UP DN 4 4 4 (2) 1 /4" x 14 LVL Beam PBS6 W60 W60 WR180 BD66 BD66 CBD66 BLWR20 () 1 /4" x 7/8" LVL BEAM BWP Wall Single Sheet one side of wall w/ 7/16" D.S.B. Nailed 8d@6"o.c. Edge and 12" o.c. Field PBD06 W618 BD66 BD66 BD66 BDR186 W60 W60 W60 WR180 WP 4 BD6 AC Garage/House BWP Wall Single Sheet one side of wall w/ 7/16" D.S.B. Nailed 8d@6"o.c. Edge and 12" o.c. Field Cover with 5/8 Fire code sheetrock 4" Concrete with WWM over compacted gravel fill sloped to door 1" slope per 10' to garage door Toilet BDR246 GARAGE 25'-9" x 25'-4" Electrical Systems: 1. Inspection is required prior to backfill of lines. 2. Provide 20 ft. of No. 4 copper wire as ground electrode in foundation footing.. Bond interior piping system with #8 bare copper. 4. Provide main jumping bond with #4 bare copper. 5. Electrical service is to be 200 amp service, 120/240 volt, 1 phase raintight, underground. 6. Provide separate 20 amp circuits to washer. 7. Provide 20 amp circuits to family and dining room, and a minimum of two 20 amp circuits to kitchen. 8. Prewire for TV, telephone in kitchen, family room, living room, and in every bedroom. 9. Install ground fault current interrupter on exterior, garage, kitchen, and bathroom convenience outlets. 10. Bottom half of outlet controlled by switch when shown.. All outlets in kitchen are to be at +44" excluding those for the refrigerator, range, disposal, and dishwasher. 12. Maximum spacing of outlets shall not exceed 12 ft. along wall line and at any wall over 24" wide in all rooms except kitchen, bath, utility, and garage. 1. Install light in walk-in closet 18" minimum horizontal from any shelf. 14. Provide a ventilation fan capable of producing a change of air every 12 minutes for bath or utility. 15. Provide smoke detector alarm conforming to Section 1210(A) U.B.C. and local building codes in every bedroom and on each floor. 16. CO2 Detector on each floor. 17. Outlets under eaves for christmas lights and heat coils 18. Lighting under cabinets 19. Night lighting on stairways and hallways Garage Door Opener Garage Door Wall Single Sheet Both sides of wall w/ 7/16" D.S.B. Nailed 8d@6"o.c. Edge and 12" o.c. Field CBD66 (2) 1 /4" x 7/8" LVL BEAM WP Residential Design SDS-CAD Specialized Design Systems P O Box 74 Mendon, Utah www.sdscad.com email: sdscad@pcu.net Toilet Corner Spa MASTER BATH 16'-1" x 9'-7" GFCI BD576 Square Shower [46] BD576 GFCI LIVING '-8" x 1'-5" (2) 1 /4" x 7/8" LVL BEAM (2) 1 /4" x 7/8" LVL BEAM DINING '-8" x 1'-5" Garage Door Opener (2) 1 /4" x 7/8" LVL BEAM WP CLIENT DRWN BY CHK'D BY 5/19/2005 John Davidson WP WP MAIN FLOOR ELECTRICAL PLAN SCALE 1/8"=1' DN JOB NO. Note: Paper size B - x 17 if printed on D - 22 x 4 scale is 2 X of stated scale @COPYRIGHT SDSCAD Specialized Design Systems SHEET NO. 9 OF

REVISIONS ELECTRICAL LEGEND SYMBOL DESCRIPTION Residential Design METER SOCKET PANEL BOX BWP Wall Single Sheet one side of wall w/ 7/16" D.S.B. Nailed 8d@6"o.c. Edge and 12" o.c. Field Developed with LL40 / DL10 Attic Trusses ATTIC 12'-10" x 2'-6" Possible Furnace Location if two furnaces required GFCI 6'-6" '-6" BATH 6'-5" x 9'-6" 1'-8" OPEN BELOW 18'-0" x 2'-8" 6'-0" SD BWP Wall Single Sheet one side of wall w/ 7/16" D.S.B. Nailed 8d@6"o.c. Edge and 12" o.c. Field DN HALL 5'-" x 9'-5" 6" Min Railing SD '-" SD SD BEDROOM '-9" x 12'-1" 2'-" GFCI 8'-2" 5'-2" BATH 8'-1" x 5'-1" '-" 12'-2" ATTIC 25'-8" x 7'-2" Wall location may vary depending on engineered truss design. Developed with LL40 / DL10 Attic Trusses BONUS ROOM 25'-8" x 17'-5" Wall location may vary depending on engineered truss design. WP DM 4 GFI CEILING FAN W/ LIGHT FLUORESCENT LIGHT FIXTURE 0V CEILING LIGHT FIXTURE 0V RECESSED LIGHT FIXTURE 0V EAVE LIGHT FIXTURE 0V CHANDILIER LIGHT FIXTURE 0V WALL LIGHT FIXTURE SINGLE POLE SWITCH THREE WAY SWITCH FOUR WAY SWITCH DIMMER SWITCH OUTDOOR SWITCH 0V DUPLEX RECEPTACLE 0V DUPLEX RECEPTACLE GROUND FAULT INTERUPTED SDS-CAD Specialized Design Systems P O Box 74 Mendon, Utah www.sdscad.com email: sdscad@pcu.net '-0" BEDROOM '-8" x 10'-" 5'-6" '-0" ATTIC 25'-8" x 7'-2" WP 0V DUPLEX RECEPTACLE W/ WEATHERPROOF COVER 0VFLOOR MOUNTED DUPLEX RECEPTACLE 240V RECEPTACLE TELEPHONE JACKS TV TELEVISION JACKS DOOR BELL PUSH BUTTON T THERMOSTAT SD SMOKE DETECTOR EXHAUST FAN CLIENT 5/19/2005 LIVING AREA 8 sq ft DC F A DOOR CHIME FIRE ALARM PANEL DRWN BY CHK'D BY John Davidson C COMPUTER POINT SECOND FLOOR ELECTRICAL PLAN JOB NO. SCALE 1/8"=1' Note: Paper size B - x 17 if printed on D - 22 x 4 scale is 2 X of stated scale @COPYRIGHT SDSCAD Specialized Design Systems SHEET NO. 10 OF

REVISIONS Window Well Residential Design Window Well Bearing Wall 2x12 joists 16" OC Bearing Wall UP SD Provide Proper Fresh Air Venting for # of Gas Appliances Floor Drain Required Flue through Roof Required if Direct Vent Appieces are not installed WH WH FAU/AC Water Softner GARAGE 25'-8" x 25'-4" ELECTRICAL SCHEDULE NUMBER QTY FLOOR DIMENSIONS DESCRIPTION E01 4 2 6X6X2 " SMOKE DETECTOR E02 2 2 X1X5 " THREE WAY E0 10 2 X1X5 " SINGLE POLE E04 2 2 X0X5 " GFCI E05 24 2 X0X5 " DUPLEX E06 1 2 16X8X8 " HALF CONE - LIGHTING GREY E07 12 2 16X16X4 " HALF DOME LIGHT - LIGHTING GREY E08 2 2 12X12X1 " EXHAUST E09 1 6X9X1 " PORCH LANTERN E10 1 1 6X6X2 " SMOKE DETECTOR E 12 1 X1X5 " THREE WAY E12 17 1 X1X5 " SINGLE POLE E1 6 1 X1X5 " DUPLEX (WEATHERPROOF) - COLOR LIGHT GRAY (MATTE) E14 2 1 X0X5 " GFCI E15 55 1 X0X5 " DUPLEX E16 2 1 X0X5 " 220V E17 1 16X8X8 " HALF CONE - LIGHTING GREY E18 8 1 16X16X4 " HALF DOME LIGHT - LIGHTING GREY E19 2 1 12X12X1 " EXHAUST E20 1 0 6X6X2 " SMOKE DETECTOR E21 8 0 16X16X4 " HALF DOME LIGHT - LIGHTING GREY E22 25 0 X0X5 " DUPLEX SDS-CAD Specialized Design Systems P O Box 74 Mendon, Utah www.sdscad.com email: sdscad@pcu.net Basement to be wired as minimum required per code for unfinished area. Allow large enough panal to accomodate finished basement requirements. BASEMENT ELECTRICAL PLAN Scale 1/8"=1' CLIENT DRWN BY CHK'D BY 5/19/2005 John Davidson JOB NO. Note: Paper size B - x 17 if printed on D - 22 x 4 scale is 2 X of stated scale @COPYRIGHT SDSCAD Specialized Design Systems SHEET NO. OF

ID Sub Cat Flr Size Description Count Extra Unit Price Tot Cost 1 General 2 GN1 0 92 high wall Interior-4 2 0 ft GN2 0 99 5/8 high wall 8" Concrete Stem Wall 1 0 ft 4 GN 0 101 1/8 high wall Interior-4 70 0 ft 5 GN4 0 99 5/8 high wall 8" Concrete Stem Wall with interior stud 168 0 ft 6 GN5 0 4 1/2 high wall 8" Concrete Stem Wall 4 0 ft 7 GN6 0 18W18D Trapezoid 12 0 8 GN7 0 heated ceiling area 12.00 0.00 sq ft 9 GN8 1 120 high wall Siding-6 82 0 ft 10 GN9 1 108 high wall Siding-6 147 0 ft GN10 1 108 high wall Interior-4 174 0 ft 12 GN 1 108 high wall Fire-6 66 0 ft 1 GN12 1 120 high wall Interior-4 4 0 ft 14 GN1 1 heated ceiling area 1418.00 0.00 sq ft 15 GN14 1 heated floor area 164.00 0.00 sq ft 16 GN15 1 heated wall area 1425.00 0.00 sq ft 17 GN16 1 heated glass area 222.00 0.00 sq ft 18 GN17 1 heated door area 49.00 0.00 sq ft 19 GN18 2 62 /16 high wall Interior-4 26 0 ft 20 GN19 2 2 /8 high wall Siding-6 86 0 ft 21 GN20 2 12 /8 high wall Siding-6 0 ft 22 GN21 2 108 high wall Siding-6 149 0 ft 2 GN22 2 108 high wall Interior-4 10 0 ft 24 GN2 2 107 1/16 high wall Siding-6 0 ft 25 GN24 2 146 9/16 high wall Siding-6 9 0 ft 26 GN25 2 12 1/16 high wall Interior-4 10 0 ft 27 GN26 2 21 /16 high wall Siding-6 6 0 ft 28 GN27 2 190 /16 high wall Siding-6 14 0 ft 29 GN28 2 76 /8 high wall Siding-6 0 ft 0 GN29 2 120 high wall Interior-4 12 0 ft 1 GN0 2 120 7/8 high wall Siding-6 0 ft 2 GN1 2 18 1/2 high wall Siding-6 6 0 ft GN2 2 59 /16 high wall Interior-4 26 0 ft 4 GN 2 heated ceiling area 1222.00 0.00 sq ft 5 GN4 2 heated wall area 1049.00 0.00 sq ft 6 GN5 2 heated door area 17.00 0.00 sq ft 7 GN6 2 heated glass area 158.00 0.00 sq ft 8 GN7 24 5/16 high wall Siding-6 6 0 ft 9 GN8 1/2 high wall Interior-4 2 0 ft 40 GN9 19 9/16 high wall Interior-4 1 0 ft 41 GN40 15 7/16 high wall Siding-6 8 0 ft 42 GN41 72 1/2 high wall Siding-6 24 0 ft 4 Subtotal: 44 Foundation 45 FO1 0 8" thick Concrete Grey 42.15 0.00 cu yd 46 FO2 0 1/2x6" foam sill seal 54 0 ft 47 FO 0 foundation bolts 79 0 48 FO4 0 20x10"h concrete footing 14.59 0.00 cu yd 49 FO5 0 no. 4 rebar (footing) 697 0 ft 50 FO6 0 no. 4 horiz. rebar (wall) 505 0 ft 51 FO7 0 no. 4 vert. rebar (wall) 2152 0 ft 52 FO8 0 16x8"h concrete footing 2.2 0.00 cu yd 5 FO9 0 2218 sq ft concrete slab 27.8 0.00 cu yd 54 FO10 0 2218 sq ft steel mesh for slab 2218.00 0.00 sq ft 55 Subtotal: 56 Masonry 57 M1 1 masonry fireplace 1 0 58 59 Subfloor 60 SF1 1 4'x8'x/4" Sheet Plywood 61 0 61 SF2 1 2x12"-16'+ floor joists - lumber 10 0 ft 62 SF 1 2x6"-16'+ mudsill - lumber 28 0 ft 6 SF4 1 2x12"-16'+ rim joists - lumber 158 0 ft 64 SF5 1 2x12"-14' rim joists - lumber 2 0 65 SF6 1 2x12"-18' rim joists - lumber 2 0 66 SF7 1 2x12"-20' rim joists - lumber 1 0 67 SF8 1 2x12"-12' floor joists - lumber 1 0 68 SF9 1 2x12"-2' floor joists - lumber 2 0 69 SF10 1 2x12"-48' floor joists - lumber 25 0 70 SF 1 2x12"-14' floor joists - lumber 2 0 71 SF12 1 2x12"-16'+ mudsill - lumber 474 0 ft 72 SF1 2 4'x8'x/4" Sheet Plywood 70 0 7 SF14 2 2x12"-16'+ rim joists - lumber 822 0 ft 74 SF15 2 2x12"-18' rim joists - lumber 2 0 75 SF16 2 2x12"-14' rim joists - lumber 5 0 76 SF17 2 2x12"-10' rim joists - lumber 1 0 77 SF18 2 2x12"-14' floor joists - lumber 17 0 78 SF19 2 2x12"-48' floor joists - lumber 9 0 79 SF20 2 2x12"-22' floor joists - lumber 6 0 80 SF21 2 2x12"-20' floor joists - lumber 0 81 SF22 2 2x12"-18' floor joists - lumber 10 0 82 SF2 2 2x12"-16'+ mudsill - lumber 05 0 ft 8 SF24 2 2x12"-4' floor joists - lumber 1 0 84 SF25 2 2x6"-16'+ ceiling joists - lumber 125 0 ft 85 SF26 2 2x6"-28' ceiling joists - lumber 4 0 86 SF27 2 2x6"-40' ceiling joists - lumber 20 0 87 SF28 2 2x6"-8' ceiling joists - lumber 4 0 88 Subtotal: 89 Framing 90 F1 0 2x4-87 1/2" Framing Fir Stud 16" OC 22 0

ID Sub Cat Flr Size Description Count Extra Unit Price Tot Cost 91 F2 0 2x4-16ft+ fir plate 79 0 ft 92 F 0 2x4"-87 1/2" fir stud 57 0 9 F4 0 2x4-95 1/8" Framing Fir Stud 16" OC 165 0 94 F5 0 4x12" door/window header 9 0 ft 95 F6 1 2x6-16ft+ fir plate 856 0 ft 96 F7 1 2x6"-10 1/2" fir stud 182 0 97 F8 1 2x6"-5 1/2" fir stud 27 0 98 F9 1 2x6"-28 /4" fir stud 2 0 99 F10 1 2x6"-8 1/2" fir stud 14 0 100 F 1 2x7-16ft+ header - lumber 0 ft 101 F12 1 2x6-16ft+ fir stud stock 507 0 ft 102 F1 1 2x12-16ft+ header - lumber 98 0 ft 10 F14 1 2x4"-10 1/2" fir stud 149 0 104 F15 1 2x4-16ft+ fir plate 527 0 ft 105 F16 1 2x4"-5 1/2" fir stud 2 0 106 F17 1 2x4"-18 1/2" fir stud 1 0 107 F18 1 2x6-16ft+ header - lumber 40 0 ft 108 F19 1 2x4-16ft+ fir stud stock 177 0 ft 109 F20 1 2x6"-18 1/2" fir stud 2 0 0 F21 1 2x8"-10 1/2" fir stud 19 0 1 F22 1 2x6"-16 /4" fir stud 4 0 2 F2 1 2x-16ft+ header - lumber 57 0 ft F24 1 2x6"-22 1/2" fir stud 16 0 4 F25 1 2x6"-104 /4" fir stud 0 5 F26 1 2x6"-12 /4" fir stud 4 0 6 F27 1 2x6"-4 1/2" fir stud 6 0 7 F28 1 2x4-16ft+ header - lumber 22 0 ft 8 F29 1 2x4"-12 1/2" fir stud 22 0 9 F0 1 2x4-10 1/2" Framing Fir Stud 16" OC 0 120 F1 1 4x12" door/window header 0 ft 121 F2 1 2x8-16ft+ fir plate 66 0 ft 122 F 1 2x8"-16 /4" fir stud 0 12 F4 1 2x8-16ft+ fir stud stock 1 0 ft 124 F5 1 2x4"-16 /4" fir stud 0 125 F6 1 2x4-5 1/2" Framing Fir Stud 16" OC 0 126 F7 2 2x4-16ft+ fir plate 701 0 ft 127 F8 2 2x4"-56 /4" fir stud 42 0 128 F9 2 2x6--2 1/16" Framing Fir Stud 16" OC 72 0 129 F40 2 2x6-16ft+ fir plate 921 0 ft 10 F41 2 2x6-16ft+ fir stud stock 550 0 ft F42 2 2x6"-10 1/2" fir stud 95 0 12 F4 2 2x4"-10 1/2" fir stud 159 0 1 F44 2 2x4"-18 1/2" fir stud 16 0 14 F45 2 2x6-16ft+ header - lumber 52 0 ft 15 F46 2 2x4-16ft+ fir stud stock 16 0 ft 16 F47 2 2x6"-10 5/16" fir stud 4 0 17 F48 2 2x-16ft+ header - lumber 87 0 ft 18 F49 2 2x7-16ft+ header - lumber 0 ft 19 F50 2 2x6"-104 1/16" fir stud 8 0 140 F51 2 2x4"-104 1/16" fir stud 1 0 141 F52 2 2x4"-20 1/2" fir stud 2 0 142 F5 2 2x4-16ft+ header - lumber 4 0 ft 14 F54 2 2x4"-12 /4" fir stud 14 0 144 F55 2 2x6"-10 /8" fir stud 15 0 145 F56 2 2x4"-10 /8" fir stud 1 0 146 F57 2 2x6"-67 7/8" fir stud 4 0 147 F58 2 2x6"-18 1/2" fir stud 2 0 148 F59 2 2x4-5 1/2" Framing Fir Stud 16" OC 0 149 F60 2 2x6-14" Framing Fir Stud 16" OC 6 0 150 F61 2 2x4-10 1/2" Framing Fir Stud 16" OC 0 151 F62 2 4x12" door/window header 6 0 ft 152 F6 2x6-16ft+ fir stud stock 225 0 ft 15 F64 2x6-16ft+ fir plate 140 0 ft 154 F65 2x4-16ft+ fir plate 9 0 ft 155 F66 2x4-15 1/16" Framing Fir Stud 16" OC 1 0 156 Subtotal: 157 Siding 158 S1 0 4'x8'x1/2" Sheet Sheetrock 19 0 159 S2 1 7" wide Siding Wood White 7 0 ft 160 S 1 4'x8'x5/8" Sheet Plywood-hrz 72 0 161 S4 1 house wrap 6666.00 0.00 sq ft 162 S5 2 4'x8'x1/2" Sheet Sheetrock 20 0 16 S6 2 7" wide Siding Wood White 191 0 ft 164 S7 2 4'x8'x5/8" Sheet Plywood-hrz 50 0 165 S8 2 house wrap 1761.00 0.00 sq ft 166 S9 7" wide Siding Wood White 684 0 ft 167 S10 4'x8'x5/8" Sheet Plywood-hrz 10 0 168 S 4'x8'x1/2" Sheet Sheetrock 0 0 169 Subtotal: 170 Ext Trim 171 EX1 0 1x4-16ft+ exterior sill 9 0 ft 172 EX2 0 1x4-16ft+ ext. window casing 26 0 ft 17 EX 1 1x7-6" door threshold 1 0 174 EX4 1 1x-16ft+ ext. door casing 17 0 ft 175 EX5 1 7 in ext. door jamb 17 0 ft 176 EX6 1 1x4-16ft+ garage door casing 52 0 ft 177 EX7 1 7 in garage door jamb 52 0 ft 178 EX8 1 18x60 in shutter 10 0 179 EX9 1 1x4-16ft+ exterior sill 62 0 ft 180 EX10 1 1x4-16ft+ ext. window casing 256 0 ft

ID Sub Cat Flr Size Description Count Extra Unit Price Tot Cost 181 EX 1 2" wide between window trim 10 0 ft 182 EX12 1 " wide between window trim 4 0 ft 18 EX1 1 1x9-6" door threshold 1 0 184 EX14 1 1x4-16ft+ ext. door casing 17 0 ft 185 EX15 1 9 in ext. door jamb 17 0 ft 186 EX16 1 x8 /4x4 Brick Antique Red 966 0 187 EX17 2 18x60 in shutter 10 0 188 EX18 2 1x4-16ft+ exterior sill 44 0 ft 189 EX19 2 1x4-16ft+ ext. window casing 19 0 ft 190 EX20 2 2" wide between window trim 5 0 ft 191 EX21 2 " wide between window trim 10 0 ft 192 EX22 2 24" wide between window trim 10 0 ft 19 Subtotal: 194 Roofing 195 R1 1 valley flashing 91 0 ft 196 R2 1 90 deg. bend roof/wall flashing 65 0 ft 197 R 1 bend to slope roof/wall flashing 69 0 ft 198 R4 1 ridge cap 90 0 ft 199 R5 1 hip ridge cap 40 0 ft 200 R6 1 Roofing Dimensional Comp. 407.00 0.00 sq ft 201 R7 1 4x8' sheets roof sheathing 15 0 202 R8 1 2x8" gable fascia 01 0 ft 20 R9 1 2x8" eave fascia 08 0 ft 204 R10 1 metal drip edge 609 0 ft 205 R 1 gutter 08 0 ft 206 R12 1 downspout 24 0 207 R1 2 2x8"-10' ridge board - lumber 4 0 208 R14 2 2x8"-16'+ ridge board - lumber 148 0 ft 209 R15 2 2x8"-18' ridge board - lumber 1 0 210 R16 2 2x8"-16' ridge board - lumber 4 0 2 R17 2 2x8"-14' ridge board - lumber 4 0 212 R18 2 2x8"-20' ridge board - lumber 4 0 21 R19 2 2x6"-16'+ rafters - lumber 412 0 ft 214 R20 2 2x6"-10' rafters - lumber 7 0 215 R21 2 2x8"-46' rafters - lumber 2 0 216 R22 2 2x8"-14' rafters - lumber 2 0 217 R2 2 2x8"-16'+ rafters - lumber 51 0 ft 218 R24 2 2x8"-10' rafters - lumber 2 0 219 R25 2 2x8"-2' rafters - lumber 1 0 220 R26 2 2x6"-20' rafters - lumber 7 0 221 R27 2 2x6"-22' rafters - lumber 44 0 222 R28 2 2x8"-12' rafters - lumber 6 0 22 R29 2 2x8"-22' rafters - lumber 6 0 224 R0 2 2x4"-16'+ rafters - lumber 185 0 ft 225 R1 2 2x8"-20' rafters - lumber 4 0 226 R2 2 2x6"-18' rafters - lumber 0 227 R 2 2x6"-14' rafters - lumber 1 0 228 R4 2 2x6"-12' rafters - lumber 6 0 229 R5 2 2x6"-16' rafters - lumber 0 20 R6 2 2x6"-24' rafters - lumber 18 0 21 R7 2 2x6"-26' rafters - lumber 2 0 22 R8 2 2x8"-26' rafters - lumber 2 0 2 R9 2 2x8"-4' rafters - lumber 1 0 24 R40 2 2x8"-24' rafters - lumber 2 0 25 Subtotal: 26 Insulation 27 IN1 0 12x16x48" batts ceiling insulation 2 0 28 IN2 1 12x16x48" batts ceiling insulation 265 0 29 IN 1 12x16x48" batts floor insulation 0 0 240 IN4 1 6x16x9" batts wall insulation 128 0 241 IN5 1 4x16x9" batts wall insulation 0 242 IN6 2 12x16x48" batts ceiling insulation 229 0 24 IN7 2 4x16x9" batts wall insulation 0 244 IN8 2 6x16x9" batts wall insulation 94 0 245 Subtotal: 246 Flooring 247 FL1 0 landing floor 2.00 0.00 sq ft 248 FL2 1 landing floor 2.00 0.00 sq ft 249 FL 1 2 1/4" wide Flooring Oak-Golden 8745 0 ft 250 FL4 1 12x12x1/4 Tile Tan 12 0 251 FL5 1 5 1/2" wide Deck Plank 2x6 1 0 ft 252 FL6 2 2 1/4" wide Flooring Oak-Golden 65 0 ft 25 FL7 2 5 1/2" wide Deck Plank 2x6 974 0 ft 254 FL8 2 12x12x1/4 Tile Tan 96 0 255 Subtotal: 256 Wall Brd 257 WB1 0 4'x8'x1/2" Sheet Sheetrock 75 0 258 WB2 0 Color Bone White 1560.00 0.00 sq ft 259 WB 0 4'x8'x/4" Sheet Sheetrock 49 0 260 WB4 1 4'x8'x1/2" Sheet Sheetrock 190 0 261 WB5 1 4'x8'x5/8" Sheet Sheetrock 19 0 262 WB6 1 Color Bone White 2047.00 0.00 sq ft 26 WB7 1 4'x8'x/4" Sheet Sheetrock 92 0 264 WB8 1 4'x8'x1/2" (wp) - sheet sheetrock 7 0 265 WB9 2 4'x8'x1/2" Sheet Sheetrock 146 0 266 WB10 2 7" wide Siding Wood White 1072 0 ft 267 WB 2 4'x8'x5/8" Sheet Plywood-hrz 15 0 268 WB12 2 Color Bone White 1085.00 0.00 sq ft 269 WB1 2 4'x8'x/4" Sheet Sheetrock 42 0 270 WB14 2 4'x8'x1/2" (wp) - sheet sheetrock 4 0

ID Sub Cat Flr Size Description Count Extra Unit Price Tot Cost 271 WB15 4'x8'x1/2" Sheet Sheetrock 10 0 272 Subtotal: 27 Windows 274 W1 0 48x48 right sliding 2 0 275 W2 1 6x60 single hung 1 0 276 W 1 6x48 single hung 2 0 277 W4 1 62x100-mu mulled unit 1 0 278 W5 1 16x60 single hung 2 0 279 W6 1 0x60 single hung 2 0 280 W7 2 24x24 24x24 Octagon 2 0 281 W8 2 6x60 single hung 0 282 W9 2 18x60 fixed glass 0 28 W10 24x24 24x24 Octagon 4 0 284 Subtotal: 285 Doors 286 D1 0 hinge: hidden 8 0 287 D2 0 0x80x1 /8R Panel Door - color brite white 2 0 288 D 0 0x80x1 /8L Panel Door - color brite white 2 0 289 D4 1 6x80x1 /4R ext. 6-Panel 1 0 290 D5 1 handle: Lever (decorative) 2 0 291 D6 1 handle: Exterior Handle (ext.) 2 0 292 D7 1 lock: Dead Bolt (interior) 2 0 29 D8 1 lock: Dead Bolt (exterior) 2 0 294 D9 1 hinge: hidden 22 0 295 D10 1 108x96 garage 2-Panel Garge Door 2 0 296 D 1 2x80x1 /8L Panel Door - color brite white 1 0 297 D12 1 6x80x1 /4L hinged-glass 1 0 298 D1 1 0x80x1 /4R hinged-glass 1 0 299 D14 1 0x80x1 /4L hinged-glass 1 0 00 D15 1 6x80x1 /4L 6-Panel 1 0 01 D16 1 0x80x1 /8 pocket 1 0 02 D17 1 0x80x1 /8R Panel Door - color brite white 0 0 D18 1 6x80x1 /4L ext. 6-Panel 1 0 04 D19 2 0x80x1 /8R Panel Door - color brite white 0 05 D20 2 hinge: hidden 16 0 06 D21 2 0x80 bifold 2 0 07 D22 2 20x80x1 /8L Panel Door - color brite white 1 0 08 D2 2 0x80x1 /8L Panel Door - color brite white 4 0 09 D24 2 9x80 bifold 2 0 10 Subtotal: Cabinets 12 C1 1 BD576 bath base cab 2 0 1 C2 1 55x6" bath cab. drawer 2 0 14 C 1 21W1D RP-2-REC 41 0 15 C4 1 hidden cab. hinge 82 0 16 C5 1 countertop - countertop pepper 20.00 0.00 sq ft 17 C6 1 front cap (bath) 16 0 ft 18 C7 1 backsplash (bath) 10 0 ft 19 C8 1 CBD66 crnr base cab 2 0 20 C9 1 10 1/4x6" cab. drawer 4 0 21 C10 1 countertop - countertop pepper 78.00 0.00 sq ft 22 C 1 countertop front cap 59 0 ft 2 C12 1 backsplash 2 0 ft 24 C1 1 W60 wall cab 5 0 25 C14 1 BDR246 base cab 1 0 26 C15 1 22x6" cab. drawer 1 0 27 C16 1 BD6 base cab 1 0 28 C17 1 1x6" cab. drawer 2 0 29 C18 1 BD66 base cab 5 0 0 C19 1 4x6" cab. drawer 5 0 1 C20 1 BDR186 base cab 1 0 2 C21 1 16x6" cab. drawer 1 0 C22 1 PBS6 pen base cab 1 0 4 C2 1 PBD06 pen base cab 1 0 5 C24 1 28x6" cab. drawer 1 0 6 C25 1 W618 wall cab 1 0 7 C26 1 BLWR20 wall cab 1 0 8 C27 1 WR180 wall cab 2 0 9 C28 2 BD96 bath base cab 1 0 40 C29 2 7x6" bath cab. drawer 1 0 41 C0 2 21W1D RP-2-REC 4 0 42 C1 2 hidden cab. hinge 8 0 4 C2 2 countertop - countertop pepper 1.00 0.00 sq ft 44 C 2 front cap (bath) 10 0 ft 45 C4 2 backsplash (bath) 6 0 ft 46 C5 2 BD6 bath base cab 1 0 47 C6 2 1x6" bath cab. drawer 1 0 48 Subtotal: 49 Int Trim 50 T1 0 1x4-16ft+ interior casing 162 0 ft 51 T2 0 4 in interior jamb 68 0 ft 52 T 0 1x4-16ft+ window apron 9 0 ft 5 T4 0 1x4-16ft+ sill 9 0 ft 54 T5 0 41x10 1/16-1" stair tread 12 0 55 T6 0 41x7 7/16" riser 12 0 56 T7 0 2" wide int. railing 490 0 in 57 T8 0 1 /16" diam. square baluster 7 0 58 T9 0 6 treads stair stringer 4 0 59 T10 0 2x10" landing joists - fir 28 0 ft 60 T 0 1x8" landing rim trim 21 0 ft

ID Sub Cat Flr Size Description Count Extra Unit Price Tot Cost 61 T12 0 2" square newel 6 0 62 T1 1 1x4-16ft+ interior casing 885 0 ft 6 T14 1 1x4-16ft+ window apron 62 0 ft 64 T15 1 1x4-16ft+ sill 62 0 ft 65 T16 1 4 in interior jamb 208 0 ft 66 T17 1 7 in interior jamb 88 0 ft 67 T18 1 1x2-16ft+ between window trim 10 0 ft 68 T19 1 1x-16ft+ between window trim 4 0 ft 69 T20 1 41x /8-1" stair tread 7 0 70 T21 1 41x8" riser 7 0 71 T22 1 2" wide int. railing 576 0 in 72 T2 1 1 /16" diam. square baluster 70 0 7 T24 1 7 treads stair stringer 2 0 74 T25 1 40x /8-1" stair tread 6 0 75 T26 1 40x8" riser 6 0 76 T27 1 6 treads stair stringer 2 0 77 T28 1 2x10" landing joists - fir 28 0 ft 78 T29 1 1x8" landing rim trim 21 0 ft 79 T0 1 2" square newel 4 0 80 T1 1 61 1/8x10 /16-1" stair tread 0 81 T2 1 61 1/8x7" riser 0 82 T 1 treads stair stringer 4 0 8 T4 1 74 1/8x 5/16-1" stair tread 0 84 T5 1 74 1/8x7" riser 0 85 T6 1 1x6-16ft+ base molding 577 0 ft 86 T7 2 1x4-16ft+ interior casing 64 0 ft 87 T8 2 4 in interior jamb 214 0 ft 88 T9 2 4 1/2" wide int. railing 78 0 in 89 T40 2 4 1/2" wide railing shoe 78 0 in 90 T41 2 1 1/2" diam. square baluster 28 0 91 T42 2 4 1/2" square half newel 2 0 92 T4 2 1x4-16ft+ window apron 44 0 ft 9 T44 2 1x4-16ft+ sill 44 0 ft 94 T45 2 1x2-16ft+ between window trim 5 0 ft 95 T46 2 1x-16ft+ between window trim 10 0 ft 96 T47 2 7 in interior jamb 4 0 ft 97 T48 2 1x24-16ft+ between window trim 10 0 ft 98 T49 2 1/2" wide int. railing 78 0 in 99 T50 2 1/2" wide railing shoe 78 0 in 400 T51 2 4" square newel 1 0 401 T52 2 4" square half newel 1 0 402 T5 2 1x6-16ft+ base molding 52 0 ft 40 Subtotal: 404 Fixtures 405 FX1 1 64W64D Corner Spa 1 0 406 FX2 1 1W4D Toilet 2 0 407 FX 1 46W46D Square Shower [46] 1 0 408 FX4 1 14W14D 14" Round 0 409 FX5 1 2W21D Double Sink [2] 1 0 410 FX6 1 12W108D Garage Door Opener 2 0 4 FX7 2 1W4D Toilet 2 0 412 FX8 2 14W14D 14" Round 2 0 41 FX9 2 41W9D Square Shower [41] 1 0 414 FX10 2 60W2D Standard Tub [60W] 1 0 415 Subtotal: 416 Appliance 417 A1 0 22W29D Gas Furnace [22W29D] 1 0 418 A2 0 20W20D Water Heater 40G 2 0 419 A 1 28W27D Dryer (gas) 1 0 420 A4 1 26W27D Washer 1 0 421 A5 1 0W26D Elec (professional) 1 0 422 A6 1 6W1D Side-by-Side 1 0 42 A7 1 5W9D Outdoor Compressor Unit 1 0 424 Subtotal: 425 Electrical 426 E1 0 wall mount Duplex 25 0 427 E2 0 ceiling mount Half Dome Light - lighting grey 8 0 428 E 0 ceiling mount Smoke Detector 1 0 429 E4 1 wall mount Duplex (weatherproof) - color light gra 6 0 40 E5 1 wall mount Duplex 55 0 41 E6 1 wall mount Porch Lantern 0 42 E7 1 wall mount Single Pole 1 0 4 E8 1 wall mount Three Way 10 0 44 E9 1 wall mount GFCI 2 0 45 E10 1 wall mount Four Way 6 0 46 E 1 wall mount Half Cone - lighting grey 0 47 E12 1 wall mount 220V 2 0 48 E1 1 ceiling mount Half Dome Light - lighting grey 8 0 49 E14 1 ceiling mount Smoke Detector 1 0 440 E15 1 ceiling mount Exhaust 2 0 441 E16 2 wall mount Duplex 2 0 442 E17 2 wall mount Single Pole 10 0 44 E18 2 wall mount GFCI 2 0 444 E19 2 wall mount Half Cone - lighting grey 1 0 445 E20 2 wall mount Three Way 2 0 446 E21 2 ceiling mount Smoke Detector 4 0 447 E22 2 ceiling mount Half Dome Light - lighting grey 12 0 448 E2 2 ceiling mount Exhaust 2 0 449 Subtotal: 450 Hardware

ID Sub Cat Flr Size Description Count Extra Unit Price Tot Cost 451 H1 1 cab drawer glide 20 0 452 45 Decks-Walks 454 DW1 1 4 1/2" wide ext. railing 51 0 ft 455 DW2 1 4 1/2" wide railing shoe 51 0 ft 456 DW 1 4x8 in beam over rail 154 0 ft 457 DW4 1 1 1/2" square. baluster 241 0 458 DW5 1 8" diam. Column [84H] half support post 4 0 459 DW6 1 10" diam. Round Column [84H] support post 5 0 460 DW7 1 8" diam. Column [84H] support post 7 0 461 DW8 1 1/2" wide ext. railing 55 0 ft 462 DW9 1 1/2" wide railing shoe 55 0 ft 46 DW10 1 2x12"-16'+ rim joists - lumber 275 0 ft 464 DW 1 2x12"-14' rim joists - lumber 2 0 465 DW12 1 2x12"-16'+ floor joists - lumber 00 0 ft 466 DW1 1 2x12"-10' rim joists - lumber 4 0 467 DW14 1 2x12"-20' rim joists - lumber 1 0 468 DW15 1 2x12"-10' floor joists - lumber 8 0 469 Subtotal: 470 471 Total:

Permit Number REScheck Compliance Certificate 200 IECC REScheck Software Version.6 Release 1 Data filename: T:\#8 Tammy and Brad anderson\mech check.rck Checked By/Date CITY: Newton STATE: Utah HDD: 715 CONSTRUCTION TYPE: Single Family WINDOW / WALL RATIO: 0.16 : 05/19/05 OF PLANS: 5-19-2005 COMPLIANCE: Passes Maximum UA = 47 Your Home UA = 408 1.7% Better Than Code (UA) Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Factor UA Ceiling 1: Flat Ceiling or Scissor Truss 1418 8.0 0.0 4 Wall 1: Wood Frame, 16" o.c. 1425 19.0 0.0 69 Window 1: Vinyl Frame:Double Pane with Low-E 222 0.50 78 Door 1: Solid 49 0.50 17 Wall 2: Wood Frame, 16" o.c. 1049 19.0 0.0 5 Window : Vinyl Frame:Double Pane with Low-E 158 0.50 55 Basement Wall 1: Solid Concrete or Masonry 1425 1.0 0.0 82 Wall height: 8.0' Depth below grade: 7.0' Insulation depth: 8.0' Window 2: Vinyl Frame:Double Pane with Low-E 2 0.50 Furnace 1: Forced Hot Air, 90 AFUE Air Conditioner 1: Electric Central Air, 10 SEER COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 200 IECC requirements in RES check Version.6 Release 1 (formerly MECcheck) and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. Builder/Designer Date

REScheck Inspection Checklist 200 IECC REScheck Software Version.6 Release 1 : 05/19/05 Bldg. Dept. Use Ceilings: [ ] 1. Ceiling 1: Flat Ceiling or Scissor Truss, R-8.0 cavity insulation Comments: Above-Grade Walls: [ ] 1. Wall 1: Wood Frame, 16" o.c., R-19.0 cavity insulation Comments: [ ] 2. Wall 2: Wood Frame, 16" o.c., R-19.0 cavity insulation Comments: Basement Walls: [ ] 1. Basement Wall 1: Solid Concrete or Masonry, 8.0' ht/7.0' bg/8.0' insul, R-1.0 cavity insulation Comments: Windows: [ ] 1. Window 1: Vinyl Frame:Double Pane with Low-E, U-factor: 0.50 For windows without labeled U-factors, describe features: # Panes Frame Type Thermal Break? [ ] Yes [ ] No Comments: [ ] 2. Window : Vinyl Frame:Double Pane with Low-E, U-factor: 0.50 For windows without labeled U-factors, describe features: # Panes Frame Type Thermal Break? [ ] Yes [ ] No Comments: [ ]. Window 2: Vinyl Frame:Double Pane with Low-E, U-factor: 0.50 For windows without labeled U-factors, describe features: # Panes Frame Type Thermal Break? [ ] Yes [ ] No Comments: Doors: [ ] 1. Door 1: Solid, U-factor: 0.50 Comments: Heating and Cooling Equipment: [ ] 1. Furnace 1: Forced Hot Air, 90 AFUE or higher Make and Model Number [ ] 2. Air Conditioner 1: Electric Central Air, 10 SEER or higher Make and Model Number Air Leakage: [ ] Joints, penetrations, and all other such openings in the building envelope that are sources of air

leakage must be sealed. [ ] Recessed lights must be 1) Type IC rated, or 2) installed inside an appropriate air-tight assembly with a 0.5" clearance from combustible materials. If non-ic rated, the fixture must be installed with a " clearance from insulation. Skylights: [ ] Minimum insulation requirement for skylight shafts equal to or greater than 12 inches is R-19. Vapor Retarder: [ ] Required on the warm-in-winter side of all non-vented framed ceilings, walls, and floors. Materials Identification: [ ] Materials and equipment must be installed in accordance with the manufacturer's installation instructions. [ ] Materials and equipment must be identified so that compliance can be determined. [ ] Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. [ ] Insulation R-values, glazing U-factors, and heating equipment efficiency must be clearly marked on the building plans or specifications. Duct Insulation: [ ] Supply ducts in unconditioned attics or outside the building must be insulated to R-8. [ ] Return ducts in unconditioned attics or outside the building must be insulated to R-4. [ ] Supply ducts in unconditioned spaces must be insulated to R-8. [ ] Return ducts in unconditioned spaces (except basements) must be insulated to R-2. [ ] Where exterior walls are used as plenums, the wall must be insulated to R-8. Insulation is not required on return ducts in basements. Duct Construction: [ ] Duct connections to flanges of air distribution system equipment must be sealed and mechanically fastened. [ ] All joints, seams, and connections must be securely fastened with welds, gaskets, mastics (adhesives), mastic-plus-embedded-fabric, or tapes. Tapes and mastics must be rated UL 181A or UL 181B. Exception: Continuously welded and locking-type longitudinal joints and seams on ducts operating at less than 2 in. w.g. (500 Pa). [ ] The HVAC system must provide a means for balancing air and water systems. Temperature Controls: [ ] Thermostats are required for each separate HVAC system. A manual or automatic means to partially restrict or shut off the heating and/or cooling input to each zone or floor shall be provided. Service Water Heating: [ ] Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. [ ] Insulate circulating hot water pipes to the levels in Table 1. Circulating Hot Water Systems: [ ] Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools: [ ] All heated swimming pools must have an on/off heater switch and require a cover unless over 20% of the heating energy is from non-depletable sources. Pool pumps require a time clock. Heating and Cooling Piping Insulation:

[ ] HVAC piping conveying fluids above 105 ºF or chilled fluids below 55 ºF must be insulated to the levels in Table 2.

Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes. Insulation Thickness in Inches by Pipe Sizes Heated Water Non-Circulating Runouts Circulating Mains and Runouts Temperature ( F) Up to 1" Up to 1.25" 1.5" to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-160 0.5 0.5 1.0 1.5 100-10 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVAC Pipes. Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping System Types Range ( F) 2" Runouts 1" and Less 1.25" to 2" 2.5" to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate (for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water, Refrigerant, 40-55 0.5 0.5 0.75 1.0 and Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD (Building Department Use Only)