SLAB AND WALL ANALYSIS AND DESIGN. Angel Francisco Martinez Civil Engineer MIDASoft

Similar documents
Transcription:

SLAB AND WALL ANALYSIS AND DESIGN Angel Francisco Martinez Civil Engineer MIDASoft

Dimensions 8m 54ft 2m 93 ft 8.8m 2m 2m 2.8m 24 m 9m 171 ft

Define Properties Define Material -Concrete ASTM C4500 Define 4 rectangle Sections as shown H B Column 0.2 m 0.2 m Slab girder 0.15 m 0.15 m Raft girder 0.3 m 0.3 m Wall marker.001 m.001 m 3 thicknesses as shown Raft Wall Slab Thickness 0.3 m 0.2 m 0.15 m

Import DXF CAD Layers Import Slab and Wall DXF Select Wall Layer and assign wall marker section Select Raft Layer and assign raft girder section Select Slab Layer and assign slab girder section

Extrude Columns Extrude columns Assign Element Type: General beam Section: Column Select center slab layer nodes as shown Extrude: -2.8 m

Mesh Slab Auto Mesh Planar Area Method: Line Elements Element Type: Plate Thickness: 0.15 Select Slab and Wall layers Mesh size 1m Domain: Slab

Extrude Walls Extrude walls Extrude Type: Line Elem to Planar Element Assign Element Type: Plate Thickness 0.2m Select center wall layer From work tree 2 Extrude: -2.8 m

Extrude Walls Extrude walls Extrude Type: Line Element to Planar Element Assign Element Type: Plate Thickness 0.2m Select center wall layer From work tree 2 Extrude: -2.8 m

Mesh Raft Auto Mesh Planar Area Method: Line Elements Element Type: Plate Thickness: 0.3m Select All Bottom nodes Mesh size 1m Domain: Raft

Load Cases Static Load Cases Create 4 load cases Assign Self Weight to dead load case

Assign Pressure Loads Assign pressure load to slab Load Case: Live Element type: Plate Assign a -7 kn/m^2 load to 0.15 thick slab

Building Generation Make copies of the first floor Select All except raft elements Copy 3 times at 2m Click Add Click Apply

Mesh Wall Auto Mesh Planar Area Method: Planar Elements Element Type: Plate Thickness: 0.2 m Select All 0.2m thick elements Mesh size 1m Domain: Wall

Generate story data Auto Generate Story Data Convert Self weight into Masses

Wind Load X Add Wind Load Load > Static Loads > Lateral > Wind Loads > Click [Add] Load Case: Wind X Wind Load Code: IBC 2012 Exposure: C X Direction Scale Factor 1 Accidental Eccentricity X Direction Positive Inspect Wind Load Profile

Wind Load Y Add Wind Load Load > Static Loads > Lateral > Wind Loads > Click [Add] Load Case: Wind Y Wind Load Code: IBC 2012 Exposure: C Y Direction Scale Factor 1 Accidental Eccentricity Y Direction Positive Inspect Wind Load Profile

Response Spectrum Functions Seismic Load Load > Seismic > Response Spectrum Data > Response Spectrum Functions Click Add Click Design Spectrum Generate Design Spectrum: IBC2012(ASCE7-10)

Seismic Load Load > Response Spectrum Data > Response Spectrum Load Cases Load Case Name: RX Excitation Angle : 0 Check : IBC2012(ASCE7-10) Check: Accidental Eccentricity Click [Add] Load Cases Name : RY Excitation Angle : 90 > Click [Add] Check: Accidental Eccentricity Click [Eigenvalue Analysis control] Number of Frequencies: 15 > Click [OK] Click [Close] Response Spectrum Load Cases

Add Spring Supports Add Surface Springs Element Type: Planar Spring Type: Linear Kx = Ky = 1,500 Kz = 15,000 kn/m^3 Select Raft thickness 0.3 m Click Apply Boundary Condition

Load combination Generate Load Combo Results > Combinations > Concrete Design > Auto Generation Select Concrete and Design Auto Generation Design Code: ACI318-14

Perform Analysis

Results: Deformations

Results: Axial Plate Forces

Results: Moments Y

Results: Shear Forces

Slab and wall load combinations Slab/Wall Load Combination Select the load combinations for the slab/wall element design. Design > Design > Meshed Design > Slab/Wall Load Combinations Select the 1 st load combination in each column to consider during the slab/wall design.

Define Design Criteria for Rebar Specify rebar size Enter the standard sizes of rebars used in the design of reinforcement for slab/wall elements. Design > Design > Meshed Design > Design Criteria for Rebar Check off [Basic Rebar for Slab] For Slab Design: Dir. 1 : 0.03 m, 0.03 m Dir. 2 : 0.05 m, 0.05 m For Wall Design Face to Center Rebar 0.02m

Slab/Wall Rebar Checking Data Specify rebar size Select all slabs from tree menu Layer Top Dir 1 Add rebar 1: #3 @ 100mm Add rebar 2: #3 Add/Replace

Slab/Wall Rebar Checking Data Specify rebar size Select all 0.2m walls from tree menu Layer Top Dir 1 Vertical 1: #3 @ 100mm Horizontal 2: #3 @ 100mm Add/Replace

Slab Flexural Design Run Design Select Avg. Nodal Dir. 1 Resistance Ratio : The ratio of the design moment to the moment resistance when the designed rebar spacing is applied.

Slab Flexural Design

Slab Flexural Design

Slab Flexural Design

Slab Flexural Design

Slab Flexural Design

Slab Flexural Design

Slab Serviceability Check Run Check Check UnCracked Creep Phi : 3 Ratio

Slab Shear Checking Run Check Check on Punching Shear Check Slab Shear Checking Produce the two-way shear (punching shear) check results at the supports of slab elements or at concentrated loads and the one way shear check results along the user-defined Shear Check Lines

Slab Shear Checking

Slab Shear Checking

Slab Shear Checking

Slab Shear Checking

Slab Shear Checking

Slab Shear Checking

Slab Shear Checking

Wall Design Run Design Specify Design Criteria as Resistance Ratio

Wall Design

Wall Design

End