RSIC ACOUSTIC ASSEMBLY FLOOR CEILING ASSEMBLY World Leader in Noise Control Solutions DIRECT FIX TO WOOD OPEN WEB TRUSS F4545.07 STC 61 IIC 54 CONSTRUCTION Hacker Industries, Inc. Firm-Fill Gypsum Concrete Hacker Industries, Inc. Firm-Fill SCM-250 Sound Control Mat Oriented Strand Board Sheathing Guardian Faces R-13 Fiberglass Insulation York PB Truss L/360 Open Web Truss @ 24" O.C. RSIC-1 Installed @ 24"x48" Clark Dietrich 087F125-18 Furring Channel @ 24" O.C. National Gypsum Gold Bond Fire-Shield C Gypsum Board STC 1 Hour See www.ul.com IIC Test Number F4545.07 STC 61 IIC 54 2016 PAC International, LLC. All Rights Reserved. (866) 774-2100 Fax (866) 649-2710 RSIC is a registered Trade Mark of PAC International, LLC.

ACOUSTICAL PERFORMANCE TEST REPORT ASTM E 90 AND ASTM E 492 Rendered to HACKER INDUSTRIES INC. Series/Model: FIRM-FILL Brand Gypsum Concrete and FIRM-FILL SCM-250e Sound Control Mat - Bare Specimen Type: Open Web Truss - 457 mm Overall Size: 3023 mm by 3632 mm STC 63 IIC 54 Test Specimen Identification: Subfloor Topping: 25.4 mm Hacker Industries, Inc. FIRM-FILL Brand Gypsum Concrete Subfloor Underlayment: 6.5 mm Hacker Industries, Inc. FIRM-FILL SCM-250e Sound Control Mat Subfloor: 18.8 mm Oriented Strand Board Sheathing Insulation: 88.9 mm Guardian Faced R-13 Fiberglass Insulation Truss: 457.2 mm York PB Truss L/360 Open Web Truss Ceiling Isolation: 28 mm PAC International RSIC-1 Classic Isolation Clips Ceiling Isolation: 22.3 mm ClarkDietrich 087F125-18 Furring/Hat Channel Ceiling: 15.9 mm National Gypsum Gold Bond Fire-Shield C Gypsum Board Reference should be made to Intertek-ATI Report F4545.07-113-11 for complete test specimen description. This page alone is not a complete report. 130 Derry Courtaa York, PA 17406aa www.archtest.com www.intertek.com/building p. 717.764.7700 f. 717.764.4129

Page 1 of 4 Acoustical Performance Test Report HACKER INDUSTRIES INC. 1600 Newport Center Drive, Suite 275 Newport Beach, California 92660 Report F4545.07-113-11 Test Date 03/07/16 Report Date 03/15/16 Revision Date 04/29/16 Project Scope Architectural Testing, Inc., a subsidiary of Intertek (Intertek-ATI), was contracted to conduct airborne sound transmission loss and impact sound transmission tests. The complete test data is included as attachments to this report. The client provided the test specimen. The specimen was constructed on the date of testing. Test Methods The acoustical tests were conducted in accordance with the following standards. The equipment listed in the attachments meets the requirements of the following standards. ASTM E 90-09, Standard Test Method for Laboratory Measurement of Airborne Sound Transmission Loss of Building Partitions ASTM E 413-10, Classification for Rating Sound Insulation ASTM E 492-09, Standard Test Method for Laboratory Measurement of Impact Sound Transmission Through Floor-Ceiling Assemblies Using the Tapping Machine ASTM E 989-06 (2012), Classification for Determination of Impact Insulation Class (IIC) ASTM E 2235-04 (2012) Standard Test Method for Determination of Decay Rates for Use in Sound Insulation Test Methods Test Procedure All testing was conducted in the VT test chambers at Intertek-ATI located in York, Pennsylvania. The microphones were calibrated before conducting the tests. The airborne transmission loss test was conducted in accordance with the ASTM E 90 test method using the single direction method. Two background noise sound pressure level and five sound absorption measurements were conducted at each of five microphone positions. Four sound pressure level measurements were made simultaneously in both rooms, at each of five microphone positions. 130 Derry Courtaa York, PA 17406aa www.archtest.com www.intertek.com/building p. 717.764.7700 f. 717.764.4129

Page 2 of 4 Test Procedure (Continued) The impact sound transmission test was conducted in accordance with the ASTM E 492 test method. Two background noise sound pressure level, two sound pressure level measurements with the tapping machine operating at each position specified by ASTM E 492, and five sound absorption measurements were conducted at each of five microphone positions. The air temperature and relative humidity conditions were monitored and recorded during all measurements. Test Conditions Source Room Receive Room Average Temperature 19.4 C Average Temperature 20.3 C Average Relative Humidity 60% Average Relative Humidity 57% Test Calculations The STC (Sound Transmission Class) and IIC (Impact Insulation Class) ratings were calculated in accordance with ASTM E 413 and ASTM E 989, respectively. Test Specimen Materials and Installation Details Material Gypsum Concrete Sound Control Mat Oriented Strand Board Sheathing Fiberglass Insulation Open Web Truss Dimensions (mm) Thickness (mm) Manufacturer and Series Hacker Industries, Inc. FIRM- 3632 by 3023 25.4 10.98 m² 41.99 kg/m² FILL Brand Note: The gypsum concrete was allowed to cure for a minimum of 14 days. The gypsum layer had a closed cell foam perimeter isolation. The product name was specified by client. Hacker Industries, Inc. FIRM- 1219 by 3023 6.5 10.98 m² 0.49 kg/m² FILL SCM-250e Note: Installed per manufacture's specifications with seams overlapping and taped 1219 by 2438 18.8 N/A 10.98 m² 13.82 kg/m² Note: The OSB was adhered to the trusses with Loctite PL 400 Subfloor adhesive. It was attached with 9D nails on 203 mm centers along perimeter and 305 mm centers along trusses. 2962 by 584 88.9 Guardian Faced R-13 10.98 m² 1.33 kg/m² Note: Installed in the cavity between trusses flush with the OSB. Hanger wire was used to keep insulation secure on 305mm 88.9 by 2933.7 457.2 York PB Truss L/360 7 m² 19.05 kg/m² Note: Installed on 610 centers using JUS414 hanger brackets. Quantity Average Weight Isolation Clips 76.9 by 35.6 28.0 PAC International RSIC-1 Classic 24 clips 0.06 kg/clip Note: Fastened to joists in a 610 mm by 1220 mm traditional pattern.

Page 3 of 4 Test Specimen Materials and Installation Details (Continued) Material Dimensions (mm) Thickness (mm) Manufacturer and Series Quantity Average Weight Furring/Hat Channel Gypsum Board 3658 by 76.2 22.3 ClarkDietrich 087F125-18 29.1 lin m 0.48 kg/m Note: Installed into the PAC International RSIC-1 Classic, spaced 610 mm on center. National Gypsum Gold Bond 1219 by 3023 15.9 10.35 m² 10.74 kg/m² Fire-Shield C Note: Fastened to furring channels on 305 mm centers with 25.4 mm type S screws. Seams finished with joint compound. Perimeter sealed with acoustical caulk. Comments The total weight of the floor/ceiling assembly was 892.8 kg. Intertek-ATI will store samples of the test specimen for four years. A drawing of the test specimen is included in the attachments. Intertek-ATI will service this report for the entire test record retention period. Test records, such as detailed drawings, datasheets, representative samples of test specimens, or other pertinent project documentation, will be retained by Intertek-ATI for the entire test record retention period. The test record retention period ends four years after the test date. This report does not constitute certification of this product nor an opinion or endorsement by this laboratory. It is the exclusive property of the client so named herein and relates only to the specimen tested. This report is intended to help in the client s quality assurance program, but it does not represent a continuous or exhaustive evaluation of the specimen tested or of other products or materials that were not evaluated. The statements and data provided herein do not constitute approval, disapproval, certification, or acceptance of performance or materials. This report may not be reproduced, except in full, without the written approval of Intertek-ATI. FOR INTERTEK-ATI: David M. Dacheux Technician II - Acoustical Testing Jordan Strybos Project Manager - Acoustical Testing Attachments (6 Pages): This report is complete only when all attachments are included. * Stated by Client/Manufacturer N/A - Non Applicable

Page 4 of 4 Revision Log Revision Date Page(s) Description R0 03/15/16 N/A Original Report Issue R1 04/29/16 Page 2 Clip spacing installation note corrected This report produced from controlled document template ATI 00629(d), Revised 02/09/15.

Attachments Instrumentation Instrument Manufacturer Model ATI Number Data Acquisition Unit National Instruments PXI-1033 63763 06/14 * Microphone Calibrator Norsonic 1251 Y002919 07/15 Receive Room Microphone Scantek 378B20 63748 05/15 Receive Room Microphone PCB Piezotronics 378B20 63744 05/15 Receive Room Microphone PCB Piezotronics 378B20 63745 05/15 Receive Room Microphone PCB Piezotronics 378B20 63746 05/15 Receive Room Microphone PCB Piezotronics 378B20 63747 05/15 Receive Room Environmental Indicator Source Room Microphone PCB Piezotronics 378B20 63738 04/15 Source Room Microphone PCB Piezotronics 378B20 63739 04/15 Source Room Microphone PCB Piezotronics 378B20 63740 04/15 Source Room Microphone PCB Piezotronics 378B20 63742 04/15 Source Room Microphone Scantek 378B20 63741 04/15 Source Room Environmental Indicator Tapping Machine Look Line s.r.l. EM50 (TM50) 65351 11/15 * The calibration frequency for this equipment is every two years per the manufacturer's recommendation. Test Chambers Comet VT Receive Room Volume 155.77 m³ VT Source Room Volume 190 m³ T7510 63810 63811 10/15 10/15 Comet T7510 63812 11/15 Date of Calibration Page 1 of 6

AIRBORNE SOUND TRANSMISSION LOSS ASTM E 90 Test Date 03/07/16 Data File No. F4545.07 Client Description Specimen Area 10.98 m² Technician Hacker Industries Inc. 25.4 mm Hacker Industries, Inc. FIRM-FILL Brand Gypsum Concrete, 6.5 mm Hacker Industries, Inc. FIRM-FILL SCM- 250e Sound Control Mat, 18.8 mm Oriented Strand Board Sheathing, 88.9 mm Guardian Faced R-13 Fiberglass Insulation, 457.2 mm York PB Truss L/360 Open Web Truss, 28 mm PAC International RSIC-1 Classic Isolation Clips, 22.3 mm ClarkDietrich 087F125-18 Furring/Hat Channel, 15.9 mm National Gypsum Gold Bond Fire-Shield C Gypsum Board David M. Dacheux Freq Background Source Receive Specimen 95% Number Absorption SPL SPL SPL TL Confidence of (Hz) (db) (m²) (db) (db) (db) Limit Deficiencies 50 48.2 27.7 103 66 34 5.20-63 45.6 30.3 102 63 36 3.40-80 46.7 16.6 108 70 38 125 36.2 11.1 107 64 44 200 28.3 10.0 105 57 49 315 24.2 9.7 106 53 55 500 23.5 8.2 104 47 60 800 21.5 7.9 105 44 64 1250 22.0 8.0 105 40 68 2000 14.6 8.7 105 38 68 3150 11.6 10.4 104 32 73 5000 12.2 13.3 105 28 76 8000 13.0 21.9 97 12 83 4.80-100 41.1 11.7 107 66 42 2.70-1.40 3 160 31.2 9.5 109 65 45 1.50 5 1.30 4 250 26.5 10.3 105 54 53 1.30 3 0.60 4 400 22.1 8.6 104 49 57 0.70 5 0.50 3 630 22.2 7.9 106 45 64 0.50 0 0.20 1 1000 21.8 7.8 105 43 65 0.40 1 0.50 0 1600 19.7 7.9 105 39 69 0.30 0 0.40 0 2500 11.3 9.4 103 36 69 0.40 0 0.30 0 4000 12.1 11.7 105 31 74 0.50 0 0.60-6300 12.2 16.7 98 16 81 0.70-0.70-10000 12.8 27.5 92 7 83 0.40 - STC Rating Deficiencies 63 29 (Sound Transmission Class) (Sum of Deficiencies) Notes: 1) Receive Room levels less than 5 db above the Background levels are highlighted in yellow. 2) Specimen TL levels listed in red indicate the lower limit of the transmission loss. 3) Specimen TL levels listed in green indicate that there has been a filler wall correction applied ATI 00614 Revised 02/09/15 Page 2 of 6

AIRBORNE SOUND TRANSMISSION LOSS ASTM E 90 Test Date 03/07/16 Data File No. F4545.07 Client Description Specimen Area 10.98 m² Technician Hacker Industries Inc. 25.4 mm Hacker Industries, Inc. FIRM-FILL Brand Gypsum Concrete, 6.5 mm Hacker Industries, Inc. FIRM-FILL SCM- 250e Sound Control Mat, 18.8 mm Oriented Strand Board Sheathing, 88.9 mm Guardian Faced R-13 Fiberglass Insulation, 457.2 mm York PB Truss L/360 Open Web Truss, 28 mm PAC International RSIC-1 Classic Isolation Clips, 22.3 mm ClarkDietrich 087F125-18 Furring/Hat Channel, 15.9 mm National Gypsum Gold Bond Fire-Shield C Gypsum Board David M. Dacheux 100 Airborne Sound Transmission Loss 90 80 Sound Transmission Loss (db) 70 60 50 40 30 20 10 Specimen TL Contour Curve 0 63 125 250 500 1000 2000 4000 8000 Frequency (Hz) ATI 00614 Revised 02/09/15 Page 3 of 6

IMPACT SOUND TRANSMISSION ASTM E 492 Test Date 03/07/16 Data File No. F4545.07 Client Description Specimen Area 10.98 m² Technician Hacker Industries Inc. 25.4 mm Hacker Industries, Inc. FIRM-FILL Brand Gypsum Concrete, 6.5 mm Hacker Industries, Inc. FIRM-FILL SCM- 250e Sound Control Mat, 18.8 mm Oriented Strand Board Sheathing, 88.9 mm Guardian Faced R-13 Fiberglass Insulation, 457.2 mm York PB Truss L/360 Open Web Truss, 28 mm PAC International RSIC-1 Classic Isolation Clips, 22.3 mm ClarkDietrich 087F125-18 Furring/Hat Channel, 15.9 mm National Gypsum Gold Bond Fire-Shield C Gypsum Board David M. Dacheux Freq Background SPL Absorption Normalized Impact SPL 95% Number Confidence (Hz) (db) (m²) (db) Limit Deficiencies 50 43.6 23.2 64 1.4-63 45.5 26.9 61 3.7-80 47.9 16.9 62 2.3-100 44.8 12.3 59 0.9 1 125 34.3 10.0 58 1.4 0 160 30.1 9.5 60 1.1 2 200 26.0 10.3 58 0.8 0 250 25.1 10.5 58 0.9 0 315 23.3 10.0 57 0.6 0 400 20.3 8.6 57 0.4 0 500 23.3 8.2 57 0.3 1 630 21.3 7.7 58 0.4 3 800 24.0 7.9 57 0.4 3 1000 23.1 7.9 56 0.8 3 1250 23.0 8.0 52 0.2 2 1600 20.3 7.9 51 0.3 4 2000 13.1 8.7 51 0.3 7 2500 9.5 9.4 45 0.2 4 3150 7.2 10.3 36 0.3 0 4000 6.8 11.7 28 0.4-5000 6.7 13.3 21 0.5-6300 7.6 16.9 14 0.4-8000 7.2 21.9 12 0.3-10000 7.4 27.5 12 0.2 - of IIC Rating Deficiencies 54 30 (Impact Insulation Class) (Sum of Deficiencies) Note: Receive Room levels less than 5 db above the Background levels are highlighted in yellow. ATI 00615 Revised 02/09/15 Page 4 of 6

IMPACT SOUND TRANSMISSION ASTM E 492 Test Date 03/07/16 Data File No. F4545.07 Client Description Specimen Area 10.98 m² Technician Hacker Industries Inc. 25.4 mm Hacker Industries, Inc. FIRM-FILL Brand Gypsum Concrete, 6.5 mm Hacker Industries, Inc. FIRM-FILL SCM- 250e Sound Control Mat, 18.8 mm Oriented Strand Board Sheathing, 88.9 mm Guardian Faced R-13 Fiberglass Insulation, 457.2 mm York PB Truss L/360 Open Web Truss, 28 mm PAC International RSIC-1 Classic Isolation Clips, 22.3 mm ClarkDietrich 087F125-18 Furring/Hat Channel, 15.9 mm National Gypsum Gold Bond Fire-Shield C Gypsum Board David M. Dacheux Impact Sound Transmission 100 10 90 20 80 30 Sound Pressure Level (db) 70 60 50 40 30 40 50 60 70 80 Impact Insulation Class (IIC) 20 90 10 Normalized Impact SPL 100 0 110 63 125 250 500 1000 2000 4000 8000 Contour Curve Frequency (Hz) ATI 00615 Revised 02/09/15 Page 5 of 6

Drawing 1-Subfloor Topping 2-Subfloor Underlayment 3-Subfloor 4-Insulation 5-Truss 6-Ceiling Isolation 7-Ceiling Page 6 of 6