METS TOP PENETRATION DRAWING INDEX: C-01 - COVER PAGE & DRAWING INDEX SHEET A-01 - WALKING PAD A-02 - METAL PARAPET CAP AND BASE FLASHING A-03 - SKYLIGHT A-04 - PLUMBING VENT A-05 - DRAIN A-06 - SCUPPER A-07 - CURB A-08 - RAISED CURB FOR TOP EQUIPMENT A-09 - BASE FLASHING WITH COUNTER FLASHING A-10 - PERIMETER EDGE A-11 - GUTTER A-12 - FIELD SEAMS C-01

METS TOP COATS APPLIED OVER GRANULES GRANULES TO BE APPLIED TO METS SILICONE TOPCOAT METS TOPCOAT EXISTING RO0F WITH EXISTING TOPCOAT WALKING PAD A-01

3-COURSE PARAPET CAP SEAMS AND SCREWS WITH GEL AND POLYESTER FABRIC SHEET METAL PARAPET CAP OPTION 1-3 COURSE WITH GEL AND POLYESTER FABRIC (SEE NOTE 1) PRIMER EXISTING METAL PARAPET CAP & BASE FLASHING 1. THE PRIMER APPLICATION IS REQUIRED BEFORE THE 3-COURSING IS STARTED A-02

EXISTING SKYLIGHT OPTION 1-3 COURSE WITH GEL AND POLYESTER FABRIC AROUND THE BASE OF SKYLIGHT AND ONTO SYSTEM (SEE NOTE 1) PRIMER EXISTING SKYLIGHT 1. THE PRIMER APPLICATION IS REQUIRED BEFORE THE 3-COURSING IS STARTED A-03

TOP OF FLASHING CAPPED OR ROLLED INTO PIPE APPROXIMATELY 1" EXISTING VENT METS COATING OPTION 1-3 COURSE WITH GEL AND POLYESTER FABRIC, GO UP PIPE MINIMUM 3" (SEE NOTE 1) PRIMER EXISTING PLUMBING VENT 1. THE PRIMER APPLICATION IS REQUIRED BEFORE THE 3-COURSING IS STARTED A-04

OPTION 1 - REMOVE DRAIN RING AND 3 COURSE WITH GEL AND POLYESTER FABRIC INTO AND AROUND THE DRAIN PARAMETER (SEE NOTE 1) METS TOPCOAT EXISTING EXISTING DRAIN DRAIN RING DECK CLAMP DRAIN BOWL DRAIN 1. THE PRIMER APPLICATION IS REQUIRED BEFORE THE 3-COURSING IS STARTED A-05

PARAPET WALL SCUPPER OPTION 1-3 COURSE WITH GEL AND POLYESTER FABRIC (SEE NOTE 1) COMPLETELY INSIDE THE SCUPPER OVERLAPPING ONTO THE WALL AT LEAST 2" ALL AROUND ALL SIDES OF SCUPPER EXISTING SCUPPER 1. THE PRIMER APPLICATION IS REQUIRED BEFORE THE 3-COURSING IS STARTED A-06

O SEALING MATERIAL SHEET METAL FLASHING METS TOP COAT OPTION 1-3 COURSE WITH GEL AND POLYESTER FABRIC AROUND THE BASE OF THE CURB AND ONTO THE SYSTEM (SEE NOTE 1) PRIMER EXISTING CURB 1. THE PRIMER APPLICATION IS REQUIRED BEFORE THE 3-COURSING IS STARTED A-07

OPTION 1-3 COURSE WITH GEL AND POLYESTER FABRIC (SEE NOTE 1) OVERLAPPED JOINTS INCLUDING PERIMETER OF METAL WITH GEL & FABRIC METS TOPCOAT OPTION 1-3 COURSE WITH GEL AND POLYESTER FABRIC PERIMETER OF CRICKET AND SEAMS (SEE NOTE 1) EXISTING EXAMPLE OF CRICKET FLASHING RAISED CURB FOR TOP EQUIPMENT 1. THE PRIMER APPLICATION IS REQUIRED BEFORE THE 3-COURSING IS STARTED A-08

3 COURSE WITH GEL AND POLYESTER FABRIC ONTO WALL AND FLASHING (SEE NOTE 1 & 2) SHEET METAL COUNTERFLASHING 3 COURSE WITH GEL AND POLYESTER FABRIC (SEE NOTE 1) EXISTING BASE FLASHING WITH COUNTER FLASHING 1. THE PRIMER APPLICATION IS REQUIRED BEFORE THE 3-COURSING IS STARTED 2. TOP OF THE FLASHING NEEDS TO BE SEALED TO WALL A-09

OPTION 1-3 COURSE WITH GEL AND POLYESTER FABRIC OVER PERIMETER EDGE (SEE NOTE 1) EXISTING PERIMETER EDGE PERIMETER EDGE 1. THE PRIMER APPLICATION IS REQUIRED BEFORE THE 3-COURSING IS STARTED 2. NEW METAL DRIP EDGE OR PARAMETER FLASHING NEEDS TO BE TREATED WITH EITHER VINEGAR OR A PRODUCT THAT WILL REMOVE THE OILY RESIDUE BEFORE PROCEEDING TO APPLY COATING PRODUCTS OVER THE NEW OILY SURFACE. A-10

SHEET METAL COUNTERFLASHING OPTION 1-3 COURSE WITH GEL AND POLYESTER FABRIC (SEE NOTE 1) EXISTING EXTEND 3-COURSING INTO GUTTER IF NEEDING TO SEAL GUTTER TO EXISTING SYSTEM SHEET METAL GUTTER GUTTER 1. THE PRIMER APPLICATION IS REQUIRED BEFORE THE 3-COURSING IS STARTED 2. NEW METAL DRIP EDGE OR PARAMETER FLASHING NEEDS TO BE TREATED WITH EITHER VINEGAR OR A PRODUCT THAT WILL REMOVE THE OILY RESIDUE BEFORE PROCEEDING TO APPLY COATING PRODUCTS OVER THE NEW METAL SURFACE. A-11

FIELD SEAM EXISTING OPTION 1-3 COURSE WITH GEL AND 4" OR 6" POLYESTER FABRIC DOWN SEAM (SEE NOTE 1) OPTION 2-3 COURSE WITH BASE AND 6" POLYESTER FABRIC FIELD SEAMS 1. THE PRIMER APPLICATION IS REQUIRED BEFORE THE 3-COURSING IS STARTED 2. 3-COURSING WITH EITHER GEL OR BASE AND FABRIC IS AN OPTION TO TREAT AN ENTIRE FIELD SEAM OR JUST TO REPAIR A DAMAGED FIELD SEAM. A-12