TRUFILL DCS ORBIT Detachable Coil System
|
|
- Winifred Atkins
- 3 years ago
- Views:
Transcription
1 ORBIT Conforming to Your Complex Needs Excellent Conformability and Concentric Filling for Outstanding Packing Density
2 ORBIT Full range of Mini Complex and new Tight Distal Loop Technology coils Our Complex Standard coils are four times more stretch resistant than our Complex Fill Coils A customized fit for aneurysms: Random loops and breaks seek out the true aneurysm periphery Mini Complex Fill Coils Tight Distal Loop Technology NEW OFFERINGS ORBIT Mini Complex Fill coils are designed for increased volumetric filling Extended offering of sizes including new 2.5 mm and 3.5 mm coils and longer 3 mm x 6 cm coil ORBIT Detachable Coils with Tight Distal Loop Technology First loop is /3 smaller than the coil diameter Avoids crossing the center of the aneurysm Fully Deployed Coil
3 ORBIT ORBIT Delivery System Advantages Conformability: The true complex structure of ORBIT Detachable Coils is designed to provide excellent conformability and concentric filling resulting in outstanding packing density. Outstanding packing density: In a recent study, use of complex-shaped coils with a wire diameter of 0.02 in. to coil cerebral aneurysms, resulted in significantly better packing than was achieved with helical coils of 0.00 in. wire diameter. Soft gripper tube results in minimal microcatheter tip deflection while coiling Stable coil delivery Gripper Tube: Transition from soft polymer delivery tube to coil Concentric Filling For Outstanding Packing Density Microcatheter Deflection Test Setup ORBIT Delivery System Competitive Wire Delivery Systems Clinical Evidence - Long-term Results Fill from periphery to core without crossing the center of the aneurysm Helps to minimize compartmentalization Complex random coil loop of ORBIT Detachable Coils Seek out free space and favor aneurysm periphery MICROCATHETERS For your coiling needs, Codman Neurovascular offers two versions of the PROWLER Microcatheter: PROWLER SELECT LP ES PROWLER 4 ORBIT Coil ORBIT Coil2 Complex Registry ORBIT Coil3 Number of Centers 37 Number of Aneurysms w/ Follow-up Recanalization 5.8% 6.2% 2.9% Retreatment 7.8% 5.% 6.5% These studies show ORBIT cases with relatively low recanalization and retreatment rates PROWLER SELECT Microcatheter Offers more stability PROWLER Microcatheter Offers more flexibility for tortuous anatomy Data on file. 2 Slob, Neurol Res. 2005;27 Suppl :S6-9; 2 3 Hirsch, J Vasc Interv Radiol 2007; 8: Efficient neck coverage Potential for shutdown of aneurysm in-flow zone
4 ORBIT ORBIT Delivery System Advantages Conformability: The true complex structure of ORBIT Detachable Coils is designed to provide excellent conformability and concentric filling resulting in outstanding packing density. Outstanding packing density: In a recent study, use of complex-shaped coils with a wire diameter of 0.02 in. to coil cerebral aneurysms, resulted in significantly better packing than was achieved with helical coils of 0.00 in. wire diameter. Soft gripper tube results in minimal microcatheter tip deflection while coiling Stable coil delivery Gripper Tube: Transition from soft polymer delivery tube to coil Concentric Filling For Outstanding Packing Density Microcatheter Deflection Test Setup ORBIT Delivery System Competitive Wire Delivery Systems Clinical Evidence - Long-term Results Fill from periphery to core without crossing the center of the aneurysm Helps to minimize compartmentalization Complex random coil loop of ORBIT Detachable Coils Seek out free space and favor aneurysm periphery MICROCATHETERS For your coiling needs, Codman Neurovascular offers two versions of the PROWLER Microcatheter: PROWLER SELECT LP ES PROWLER 4 ORBIT Coil ORBIT Coil2 Complex Registry ORBIT Coil3 Number of Centers 37 Number of Aneurysms w/ Follow-up Recanalization 5.8% 6.2% 2.9% Retreatment 7.8% 5.% 6.5% These studies show ORBIT cases with relatively low recanalization and retreatment rates PROWLER SELECT Microcatheter Offers more stability PROWLER Microcatheter Offers more flexibility for tortuous anatomy Data on file. 2 Slob, Neurol Res. 2005;27 Suppl :S6-9; 2 3 Hirsch, J Vasc Interv Radiol 2007; 8: Efficient neck coverage Potential for shutdown of aneurysm in-flow zone
5 ORBIT ORBIT Delivery System Advantages Conformability: The true complex structure of ORBIT Detachable Coils is designed to provide excellent conformability and concentric filling resulting in outstanding packing density. Outstanding packing density: In a recent study, use of complex-shaped coils with a wire diameter of 0.02 in. to coil cerebral aneurysms, resulted in significantly better packing than was achieved with helical coils of 0.00 in. wire diameter. Soft gripper tube results in minimal microcatheter tip deflection while coiling Stable coil delivery Gripper Tube: Transition from soft polymer delivery tube to coil Concentric Filling For Outstanding Packing Density Microcatheter Deflection Test Setup ORBIT Delivery System Competitive Wire Delivery Systems Clinical Evidence - Long-term Results Fill from periphery to core without crossing the center of the aneurysm Helps to minimize compartmentalization Complex random coil loop of ORBIT Detachable Coils Seek out free space and favor aneurysm periphery MICROCATHETERS For your coiling needs, Codman Neurovascular offers two versions of the PROWLER Microcatheter: PROWLER SELECT LP ES PROWLER 4 ORBIT Coil ORBIT Coil2 Complex Registry ORBIT Coil3 Number of Centers 37 Number of Aneurysms w/ Follow-up Recanalization 5.8% 6.2% 2.9% Retreatment 7.8% 5.% 6.5% These studies show ORBIT cases with relatively low recanalization and retreatment rates PROWLER SELECT Microcatheter Offers more stability PROWLER Microcatheter Offers more flexibility for tortuous anatomy Data on file. 2 Slob, Neurol Res. 2005;27 Suppl :S6-9; 2 3 Hirsch, J Vasc Interv Radiol 2007; 8: Efficient neck coverage Potential for shutdown of aneurysm in-flow zone
6 ORBIT CONSTRUCTION Coil Outer Diameter: 0.02 inches Usable Length: 75 cm Easy-to-Use Introducer Design ordering information: PRODUCT COMPATIBILITY Compatible with Dual Markerband PROWLER SELECT LP ES and PROWLER SELECT Plus Microcatheters as well as PROWLER 4 and PROWLER Plus Microcatheters USA Codman & Shurtleff, Inc. 325 Paramount Drive Raynham, MA To place an order, call For technical/product questions, call For product availability, please contact your Codman Neurovascular representative. TDL Shape Coil Length Softness Catalog No. Diameter (mm) (cm) Type Mini Complex Fill 637MF FILL 637MF FILL 637MF FILL 637MF FILL 637MF FILL 637MF FILL 637MF FILL 637MF FILL 637MF FILL 637MF FILL 637MF FILL 637MF FILL 637MF FILL 637MF FILL 638MF FILL 638MF FILL Complex Fill 637CF FILL 637CF FILL 637CF FILL 637CF FILL 637CF FILL 637CF FILL 637CF FILL 637CF FILL 637CF FILL 637CF FILL 637CF FILL 637CF FILL 637CF FILL Shape Coil Length Softness Catalog No. Diameter (mm) (cm) Type Complex Standard 637CS STANDARD 637CS STANDARD 637CS STANDARD 637CS STANDARD 637CS STANDARD 637CS STANDARD 637CS STANDARD 637CS STANDARD 637CS STANDARD 637CS STANDARD Helical Fill 637HF FILL 637HF FILL 637HF FILL 637HF FILL 637HF FILL 637HF FILL 637HF FILL 637HF FILL 637HF FILL 637HF FILL 637HF FILL 637HF FILL 637HF FILL 637HF FILL 637HF FILL 637HF FILL 637HF FILL 637HF FILL Shape Coil Length Softness Catalog No. Diameter (mm) (cm) Type Complex Fill - Tight Distal Loop 638MF FILL 638MF FILL 638CF FILL 638CF FILL 638CF FILL 638CF FILL 638CF FILL 638CF FILL 638CF FILL 638CF FILL Complex Standard - Tight Distal Loop 638CS STANDARD 638CS STANDARD 638CS STANDARD 638CS STANDARD 638CS STANDARD 638CS STANDARD 638CS STANDARD 638CS STANDARD 638CS STANDARD 638CS STANDARD TRUFILL DCS Syringe II / ORBIT Detachable Coil Essential Prescribing Information (EPI) INTENDED USE: The ORBIT Detachable Coil is indicated for embolizing certain intracranial aneurysms that, because of their morphology, location, or the patient s general medical condition, are considered by the treating neurosurgical team to be:. Very high-risk for management by traditional operative techniques; 2. Inoperable and for embolizing other vascular malformations such as arteriovenous malformations and arteriovenous fistulae of the neurovasculature. The ORBIT Detachable Coil is also intended for arterial and venous embolization in the peripheral vasculature. CONTRAINDICATIONS: The use of the ORBIT Detachable Coil is contraindicated when: superselective placement is not possible; the arteries supplying the lesion are not large enough to accept embolic material; patent extra-to-intracranial anastomoses are present; end arteries lead directly to cranial nerves; the A-V shunt is bigger than the size of the coil; there is severe atheromatous disease; in the presence or likely onset of vasospasm. WARNINGS: Therapeutic embolizations to occlude blood vessels are high-risk procedures. The procedure should be carried out under the direction of personnel with the requisite interventional training and thorough knowledge of angiographic techniques, especially coil embolization techniques. Appropriate facilities should be available for managing the potential complications of the procedure. Contaminants found in the angiography room may cause foreign body reactions or infection. The physician must use the utmost caution to avoid introducing contaminants. Incomplete occlusion of vascular bed or territories may give rise to hemorrhage, ischemia, infarction, development of alternative vascular pathways, or recurrence of symptoms. Do not use any other syringes other than the specified TRUFILL DCS Syringe for operation of the ORBIT Detachable Coil. The introduction of air emboli may occur during detachment if one of the following is not performed properly: saline purge of the syringe to remove all air prior to connecting to the delivery tube hub; saline purge of the delivery tube with visual confirmation at the hub; saline flush of the delivery tube hub prior to any system reconnections. Do not use the distal tip of the infusion catheter to manipulate or reposition embolic coils previously detached in the patient s vasculature. Do not reuse. Discard after one procedure. Failure to open the second RHV sufficiently prior to slow and careful removal of the delivery tube from the patient could result in damage to the distal portion of the delivery tube. PRECAUTIONS: ORBIT Detachable Coils are delicate devices and should be handled carefully. Prior to use and when possible during the procedure, inspect the system for bends or kinks. Do not use a coil system that shows signs of damage. Do not expose the product to organic solvents. The long-term effects of this product on extravascular tissues have not been established, so care should be taken to retain this device in the intravascular space. Multiple embolization procedures may be required to achieve the desired occlusion of some vessels or aneurysms. The ORBIT Detachable Coil is intended for one use only. Do not resterilize and/or reuse the device. After use, dispose in accordance with hospital, administrative and/or local government policy. Store in a cool, dark, dry place. Do not use if package is open or damaged. Use prior to the Use By date. Angiography is necessary for the pre-embolization evaluation, operative control, and post-embolization follow up. Ensure proper detachable coil selection according to vascular territory and measurements taken from a baseline angiogram. ADVERSE EVENTS: Complications specific to embolization procedures may occur at any time during or after the procedure and may include, but are not limited to, the following: ischemia at an undesired location; stroke or cerebral infarction; coil migration into normal vessels adjacent to the lesion; pulmonary embolism; vessel dissection, perforation, rupture and hemorrhage; neurological deficits; injury to normal vessels or tissue; infection; allergic reaction; vasospasm; and/or death. Caution: Federal (USA) law restricts these devices to sale by or on the order of a physician. Prior to use, please read the more detailed information in the Instructions for Use. The third party trademarks used herein are trademarks of their respective owners. ORBIT, TRUFILL, Prowler and Prowler Select are registered trademarks of Codman & Shurtleff, Inc Codman & Shurtleff, Inc. All Rights Reserved. Codman Neurovascular is a business unit of Codman & Shurtleff, Inc. VC/SE CNV
TRUFILL n-butyl Cyanoacrylate (n-bca) Liquid Embolic System
TRUFILL n-butyl Cyanoacrylate (n-bca) Liquid Embolic System Codman & Shurtleff, Inc. 325 Paramount Drive Raynham, MA 02767-0350 USA 800 225 0460 +1 508 828 3000 LCN 206362-001/A 2009 Codman & Shurtleff,
Azur Peripheral Coil System Helical HydroCoil Embolization System (Detachable) Instructions for Use
Azur Peripheral Coil System Helical HydroCoil Embolization System (Detachable) Instructions for Use DEVICE DESCRIPTION The Detachable Azur Peripheral Coil System (Azur system) consists of a coil implant
ASAHI Masters PARKWAY SOFT. ASAHI Masters PARKWAY HF
ASAHI Masters PARKWAY SOFT Microcatheter ASAHI Masters PARKWAY HF Microcatheter SYMBOLS 1 English 2 AMK-DT207 Ver.1.40 / 11TS028 SYMBOLS Legal manufacturer Consult instructions for use Do not use if package
ASAHI Masters PARKWAY HF KIT
ASAHI Masters PARKWAY HF KIT Guide Wire Pre-loaded Microcatheter SYMBOLS 1 English 2 AMK-DT202 Ver.1.30 / 11TS023 SYMBOLS Legal manufacturer GC Minimum guiding catheter I.D. Do not use if package is damaged
EkoSonic MACH4 Endovascular Device Instructions for Use
EkoSonic MACH4 Endovascular Device Instructions for Use Indications for Use The EkoSonic Endovascular System is indicated for the: Ultrasound facilitated, controlled and selective infusion of physician-specified
Drug-Eluting Beads Current Indication Status
Drug-Eluting Beads Current Indication Status dcbead.com/allbeadsarenotthesame DC Bead INDICATIONS The CE Mark approved indication statements for DC Bead include loading with doxorubicin and with irinotecan.
Evolution of Embolization
Evolution of Embolization WITH JAFAR GOLZARIAN, MD; FRANCOIS CORNELIS, MD, PhD; COREY L. TEIGEN, MD; DMITRI E. SAMOILOV, MD; AND FRANK R. ARKO III, MD Jafar Golzarian, MD Professor of Radiology Department
RePlay Hemostasis Clip
RePlay Hemostasis Clip Instructions for use. Read carefully prior to use. Caution: Federal (U.S.A.) Law restricts this device to sale by or on the order of a physician. Diversatek Healthcare Corporate
GDC Detachable Coils, GDC 360o Detachable Coils, Matrix2 Detachable Coils, and Target Detachable Coils
GDC Detachable Coils, GDC 0o Detachable Coils, Matrix Detachable Coils, and Target Detachable Coils Magnetic Resonance Imagining (MRI) Compatibility (Neurovascular Use) Non-clinical testing and analysis
Acoustic Pulse Thrombolysis Treatment
Acoustic Pulse Thrombolysis Treatment In-Service Presentation Acoustic Pulse Thrombolysis treatment is a minimally invasive system for accelerating thrombus dissolution. FORWARD-LOOKING STATEMENT This
intervention embosphere embogold quadrasphere bearing nspva
Embolics intervention embosphere embogold quadrasphere bearing nspva Merit Medical brings efficiency, safety, and value to embolotherapy with a comprehensive line of Clinically PROVEN products designed
Instructions for Use Reprocessed Coronary Sinus Diagnostic Electrophysiology Catheter
Reprocessed by Instructions for Use Reprocessed Coronary Sinus Diagnostic Electrophysiology Catheter Reprocessed Device for Single Use STERILE Explanation of Symbols Federal Law in the USA restricts this
INSTRUCTIONS FOR USE FOR:
INSTRUCTIONS FOR USE FOR: en English INSTRUCTIONS FOR USE GORE ENFORM INTRAPERITONEAL BIOMATERIAL Carefully read all instructions prior to use. Observe all instructions, warnings, and precautions noted
MIIG INJECTABLE Graft The following languages are included in this packet:
MIIG INJECTABLE Graft 128801-10 The following languages are included in this packet: English (en) Deutsch (de) Nederlands (nl) Français (fr) Español (es) Italiano (it) Português (pt) 中文 - Chinese (sch)
Page 1 of 6 Reprocessed by. Caution: Federal (U.S.A.) law restricts this device to sale by or on the order of a physician.
Page 1 of 6 Reprocessed by Instructions for Use Reprocessed 3D Diagnostic Ultrasound Catheters Reprocessed Device for Single Use Caution: Federal (U.S.A.) law restricts this device to sale by or on the
Contrast media administration - Alternatives to the cubital vein
Contrast media administration - Alternatives to the cubital vein Radiologists must be prepared for administration of contrast media via the intraosseous route & CVC Hampus Eklöf MD, PhD CMO Unilabs radiology
PER F ORM ANC E b y d e s i g n. Pioneering TEVAR Therapy, Time and Time Again. CONFORMABLE
PER F ORM ANC E b y d e s i g n Pioneering TEVAR Therapy, Time and Time Again. CONFORMABLE T H O R A C I C E N D O P R O S T H E S I S Time-Tested Success For more than 16 years, the GORE TAG Device has
Decide, guide, treat and confirm: The Philips Volcano CLI solution
Decide, guide, treat and confirm: The Philips Volcano CLI solution Trademarks are the property of Koninklijke Philips N.V. or their respective owners Critical Limb Ischemia Affects the Lives of Many Patients
CapSure Permanent Fixation System
CapSure Permanent Fixation System Permanent Fixation Redefined Advancing the Fixation Experience Recipient of 2015 SLS Innovations of the Year recognition. SOFT TISSUE REPAIR Right Procedure. Right Product.
TREAT SMARTER. ACHIEVE MORE. When Treating Thrombus
TREAT SMARTER. ACHIEVE MORE. When Treating Thrombus Treat Smarter When you want fast, safe, predictable results EKOS Ultrasound Accelerated Thrombolysis Unlocks The Clot Without Ultrasonic Energy With
Instructions for Use Reprocessed Electrophysiology Catheter Cables
Reprocessed by Instructions for Use Reprocessed Electrophysiology Catheter Cables Reprocessed Device for Single Use STERILE Explanation of Symbols Federal Law in the USA restricts this device to sale by
Steerable Guide Wires Precision With Every Turn
Steerable Guide Wires Precision With Every Turn The Wholey * and Covidien families of guide wires combine the right amount of support and flexibility along with 1:1 torque control to provide precision
White Paper: Implantable Fabrics Revolutionize Neurovascular Devices. Andrew Metzger Senior Process Development Engineer
White Paper: Implantable Fabrics Revolutionize Neurovascular Devices Andrew Metzger Senior Process Development Engineer In the neurovascular device segment, development is focused on minute, precision
Instructions for Use Reusable Electrophysiology Catheter Cables
Processed by Instructions for Use Reusable Electrophysiology Catheter Cables STERILE Explanation of Symbols Federal Law in the USA restricts this device to sale by or on the order of a physician Sterilized
PREVELEAK Surgical sealant
PREVELEAK Surgical sealant Rx only Instructions for Use DEVICE DESCRIPTION PREVELEAK Surgical sealant (PREVELEAK) is a sealant developed to seal suture holes formed during surgical repair of the circulatory
INSTRUCTIONS FOR USE FOR:
INSTRUCTIONS FOR USE FOR: B I O M A T E R I A L en English INSTRUCTIONS FOR USE FOR GORE SYNECOR INTRAPERITONEAL BIOMATERIAL INDICATIONS The GORE SYNECOR Intraperitoneal Biomaterial device is intended
Image guided therapy. Neuro suite. Azurion. Neuro suite. Neuro decisions are based on what you see, so see more
Image guided therapy Azurion Neuro decisions are based on what you see, so see more Defining the future of Image Guided Therapy Innovative solutions across the health continuum The areas of diagnosis and
Advancing the Open Ventral Hernia Repair Experience
Advancing the Open Ventral Hernia Repair Experience SOFT TISSUE REPAIR Right Procedure. Right Product. Right Outcome. Hernia Repair Fixation Absorbable Fixation System Optimized Design for Open Ventral
EkoSonic Endovascular System
EkoSonic Endovascular System Nursing In-Service EKOS Corporation is a BTG International group company US-EKO-1800192 Forward-looking statement This presentation and information communicated verbally to
Instructions for Use Reusable Ablation Catheter Cables
Processed by Instructions for Use Reusable Ablation Catheter Cables STERILE Explanation of Symbols Federal Law in the USA restricts this device to sale by or on the order of a physician Sterilized by Ethylene
Shapability, Memory, and Luminal Changes in Microcatheters after Steam Shaping: A Comparison of 11 Different Microcatheters
AJNR Am J Neuroradiol 26:2610 2616, November/December 2005 Shapability, Memory, and Luminal Changes in Microcatheters after Steam Shaping: A Comparison of 11 Different Microcatheters Hiro Kiyosue, Yuzo
Advancing minimally invasive. therapeutics through novel device. development. Minima y Invasive New Technologies T H E L E O N A M. A N D H A R R Y B.
MIN T Minima y Invasive New Technologies Advancing minimally invasive therapeutics through novel device development T H E L E O N A M. A N D H A R R Y B. C H A R I T A B L E T R U S T he Minimally Invasive
Complex Left Atrial (CLA) Best Practices for Navigant
Complex Left Atrial (CLA) Best Practices Cavo-tricuspid Isthmus (CTI) Dependent Flutter Best Practices CTI Ablation Procedure Background RF Ablation of CTI dependent flutter is a standard procedure in
ARROW EDGE. Antegrade-tunneled chronic hemodialysis catheter
ARROW EDGE Antegrade-tunneled chronic hemodialysis catheter ARROW EDGE HEMODIALYSIS CATHETERIZATION SET CONTENTS: 1 Catheter: 15 Fr. 1 Arrow SmartSeal Hemostatic Peelable Dialysis Sheath: 16 Fr. 1 Spring
CAUTION: U.S. Federal law restricts this device to sale by or on the order of a licensed physician.
TM CAUTION: U.S. Federal law restricts this device to sale by or on the order of a licensed physician. TABLE OF CONTENTS Section Port Styles 4 Description 5 Indications 5 Contraindications 5-6 Information
HANDLING OF WRIGHT MEDICAL DISPOSABLE PROPHECY TM ANKLE INSTRUMENTS
HANDLING OF WRIGHT MEDICAL DISPOSABLE PROPHECY TM ANKLE INSTRUMENTS 153290-0 The following languages are included in this packet: English (en) For additional languages, visit our website www.wright.com
VASCULAR ACCESS PRELUDE SHEATH INTRODUCERS. Merit Medical s Innovative Family of Vascular Access Products A GREAT INTRODUCTION
VASCULAR ACCESS PRELUDE SHEATH INTRODUCERS Merit Medical s Innovative Family of Vascular Access Products A GREAT INTRODUCTION THE PRELUDE FAMILY OF SHEATH INTRODUCERS A comprehensive product line offering
Conformability without Compromise
Conformability without Compromise THE STANDARD IN Conformability AND Designed for flexibility and conformability in tortuous anatomy. Optimized aortic wall apposition in angulated arch anatomy without
Clinical Applications. ImagingRite. Interventional Radiology
Clinical Applications ImagingRite Interventional Radiology ImagingRite, a comprehensive suite of imaging tools offered with Infinix -i angiographic systems, was designed to assist clinicians in optimizing
TRANSFORMING NEUROLOGICAL HEALTHCARE.
TRANSFORMING NEUROLOGICAL HEALTHCARE. TRANSFORMING THE WAY THE WORLD TREATS NEUROLOGICAL DISORDERS AND DISEASES. At Medtronic, our goal is to be an intrinsic partner in global neurological care, so that
3D Roadmapping in neuroendovascular procedures an evaluation
Clinical applications 3D Roadmapping in neuroendovascular procedures an evaluation H. Okumura T. Terada D. Babic R. Homan T. Katsuma Department of Neurosurgery, Wakayama Rosai Hospital, Wakayama, Japan.
Polidocanol Endovenous Microfoam (PEM) Comprehensive Treatment for Great Saphenous Vein System (GSV) Incompetence
Polidocanol Endovenous Microfoam (PEM) Comprehensive Treatment for Great Saphenous Vein System (GSV) Incompetence By Ariel D. Soffer, MD, FACC Dr. Ariel David Soffer-Bio NCVH Vein Forum Fellow of the American
3M Tegaderm PICC/CVC Securement Device + I.V. Advanced Securement Dressing Product Description
3M Tegaderm PICC/CVC Securement Device + I.V. Advanced Securement Dressing Product Description 3M Tegaderm PICC/CVC Securement Device + I.V. Advanced Securement Dressing ( Securement System ) is designed
Conformability without Compromise
Conformability without Compromise THE STANDARD IN Conformability AND Designed for flexibility and conformability in tortuous anatomy. Optimized aortic wall apposition in angulated arch anatomy without
Bleed Management MAKING A DIFFERENCE TO HEALTH
Bleed Management We offer a comprehensive range of interventional devices to help in the management of GI bleeds. Suitable for both Endoscopic and Surgical procedures. MAKING A DIFFERENCE TO HEALTH Viper
Comfort your patient deserves. Strength you demand.
POLYSITE LOW PROFILE HYBRID PORTS Comfort your patient deserves. Strength you demand. We never settle because you never settle. Throughout our 35-year history, clinicians and patients have benefited from
TRELLIS COLLAGEN RIBBON
TRELLIS COLLAGEN RIBBON 147321-1 English (en) The following languages are included in this packet: M Wright Medical Technology, Inc. 5677 Airline Rd. Arlington, TN 38002 USA www.wmt.com August 2012 Printed
Vascular. Making Best Use of Trinias Applications for Lower Extremity Interventional Procedures. 1. Introduction
Vascular Making Best Use of Trinias Applications for Lower Extremity Interventional Procedures Yasuhiro Takahashi, M.D. Department of Cardiology, The Fraternity Memorial Hospital Yasuhiro Takahashi 1.
BIOTAPE XM TISSUE MATRIX The following languages are included in this packet:
BIOTAPE XM TISSUE MATRIX 150866-0 The following languages are included in this packet: English (en) Deutsch (de) Nederlands (nl) Français (fr) Español (es) Italiano (it) Português (pt) 中文 -Chinese (sch)
PRODUCT DEVELOPMENT OF A NEUROVASCULAR EMBOLIZATION DEVICE. A Thesis CHRISTOPHER JAMES MICIELLI
PRODUCT DEVELOPMENT OF A NEUROVASCULAR EMBOLIZATION DEVICE A Thesis by CHRISTOPHER JAMES MICIELLI Submitted to the Office of Graduate Studies of Texas A&M University in partial fulfillment of the requirements
Ventrio ST Hernia Patch featuring Sepra Technology
Ventrio ST Hernia Patch featuring Sepra Technology Sepra Technology An extensively studied barrier with more than 10 publications and used clinically since 2007. Unique hydrogel barrier swells to minimize
ProCol Vascular Bioprosthesis
Instructions for Use 1. DEVICE DESCRIPTION The ProCol Vascular Bioprosthesis is derived from bovine mesenteric vein processed with glutaraldehyde. Collateral branches are ligated with surgical suture and
P E D A L A P P R O A C H
PEDAL APPROACH PEDAL APPROACH SET-UP & ACCESS ANGIOGRAPHY INTERVENTION HEMOSTASIS INTEGRATE Merit Medical offers the most comprehensive suite of products for pedal access. From Set Up & Access to Hemostasis,
Lombard Medical, Inc. (NASDAQ:EVAR) June 2016
Lombard Medical, Inc. (NASDAQ:EVAR) June 2016 Safe Harbor This presentation contains forward-looking statements as that term is defined in the Private Securities Litigation Reform Act of 1995, as amended.
Whitepaper: Precision Micro-Braiding for Implantable Devices
Whitepaper: Precision Micro-Braiding for Implantable Devices Keys to Design Success When Contemplating Medical Device Braids By: Robert Kiefer and Keith Smith Braided textile structures are among the most
Beyond Tried. True. GuideLiner V3 Catheter Guide Extension Catheter With Half-Pipe Technology
Beyond Tried. True. GuideLiner V3 Catheter Guide Extension Catheter With Half-Pipe Technology Beyond Tried. True. In 2009, the GuideLiner Catheter revolutionized the concept of guide extension, creating
RapidPort EZ Access Port Kit DIRECTIONS FOR USE (DFU)
RapidPort EZ Access Port Kit DIRECTIONS FOR USE (DFU) RapidPort EZ Access Port Kit Ref. No. C-2304 Standard RapidPort EZ Access Port Kit Ref. No. C-2306 Large RapidPort EZ Access Port Kit INTRODUCTION
In-Service Presentation
In-Service Presentation 12016 2016 Boston Boston Scientific. Scientific. Corporation or its or Affiliates. its Affiliates. All rights All rights reserved. reserved. PI-379301-AA EU MAR2016 Agenda WallFlex
Instructions for Use Reprocessed Masimo LNCS Pulse Oximeter Sensor. Reprocessed Device for Single Use
Reprocessed by Instructions for Use Reprocessed Masimo LNCS Pulse Oximeter Sensor Reprocessed Device for Single Use Caution: Federal (U.S.A.) law restricts this device to sale by or on the order of a physician.
Time to Go Augmented in Vascular Interventional Neuroradiology?
Time to Go Augmented in Vascular Interventional Neuroradiology? René Anxionnat, Marie-Odile Berger, Erwan Kerrien To cite this version: René Anxionnat, Marie-Odile Berger, Erwan Kerrien. Time to Go Augmented
S.M.A.R.T. Our inspiration came right from the source. Feeling is believing. S.M.A.R.T. Flex Vascular Stent System. LinkedIn page
to receive our latest news and key activities. S.M.A.R.T. Flex Vascular System Our inspiration came right from the source. S.M.A.R.T. Flex Vascular System Feeling is believing. LinkedIn page Follow us
English. DC Bead LUMI Radiopaque Embolic Drug-Eluting Bead. INSTRUCTIONS FOR USE Version 2
English DESCRIPTION: DC Bead LUMI Radiopaque Embolic Drug-Eluting Bead INSTRUCTIONS FOR USE Version 2 STERILE:SINGLE USE ONLY: (Do not use if package is opened or damaged) DC Bead LUMI are precisely calibrated,
RapidPort EZ Port Applier DIRECTIONS FOR USE (DFU)
RapidPort EZ Port Applier DIRECTIONS FOR USE (DFU) RapidPort EZ Port Applier Ref. No. C-20390 RapidPort EZ Port Applier INTRODUCTION The RapidPort EZ Port Applier is an optional accessory for the LAP-BAND
Protect the Neck. Lieven Maene, MD. Marc Bosiers Koen Deloose Joren Callaert. Patrick Peeters Jürgen Verbist. Lieven Maene Roel Beelen.
A.Z. Sint-Blasius, Dendermonde Marc Bosiers Koen Deloose Joren Callaert Imelda Hospital, Bonheiden Protect the Neck Patrick Peeters Jürgen Verbist OLV Hospital, Aalst Lieven Maene Roel Beelen R.Z. Heilig
BREAKING BOUNDARIES WITH ICE
IcePearl 2.1 CX L Needle IceFORCE 2.1 CX L Needle 23cm Length for Deep Tumours IceSphere 1.5 S Needle Short Shaft for Superficial Lesions IcePearl 2.1 CX Needle IceFORCE 2.1 CX Needle Large Ice, Smaller
Clinical Experience Using SONIALVISION G4 Multi-Purpose R/F System for Angiographic Examinations
R/F Clinical Experience Using SONIALVISION G4 Multi-Purpose R/F System for Angiographic Examinations Department of Central Radiology, Takasago Municipal Hospital Naoki Shioya Mr. Naoki Shioya 1. Introduction
JUL Sponsor/Applicant Name and Address Penumbra, Inc Harbor Bay Parkway Alameda, CA 94502, USA
JUL 0 3 2014-510(k) Summary ILH 134f (as required by 21 CER 807.92) Pursuant to Section 12, Part (a)(i)(3a) of the Safe Medical Devices Act of 1990, Penumbra Inc. is providing the summary of Substantial
Flow Rate Measurement In Emissions Monitoring
00870-0100-4809 July 2006 Page 1 Flow Rate Measurement In Emissions Monitoring Regulation The Kyoto Protocol requires a reduction in greenhouse gas emissions. The 485 Annubar Primary Element in stackbar
ACCESS OPTIONS FOR PATIENTS WITH VENOUS OUTFLOW INSUFFICIENCY SYSTEM MERIT IS COMMITTED TO DIALYSIS ACCESS
ACCESS OPTIONS FOR PATIENTS WITH VENOUS OUTFLOW INSUFFICIENCY SYSTEM MERIT IS COMMITTED TO DIALYSIS ACCESS SYSTEM When end stage renal disease patients are catheter-dependent or are approaching catheter
Great Saphenous Vein Occlusion with Cyanoacrylate: An Alternative to Endovenous Laser Ablation?
acta medica orıgınal artıcle Great Saphenous Vein Occlusion with Cyanoacrylate: An Alternative to Endovenous Laser Ablation? Fatma Gonca Eldem*, [MD] Selin Ardalı 1, [MD] Bora Peynircioğlu 1, [MD] 1, Hacettepe
ACTELION TRANSFORMATION ON THE WAY. Jean-Paul Clozel Chief Executive Officer. Copyright 2016 Actelion Pharmaceuticals Ltd
ACTELION 2015 2020 TRANSFORMATION ON THE WAY Jean-Paul Clozel Chief Executive Officer Copyright The following information contains certain forward-looking statements, relating to the company s business,
January 13, Texas Medical Technologies, Inc. Consultant Smith Associates 1468 Harwell Avenue Crofton, Maryland 21114
DEPARTMENT OF HEALTH & HUMAN SERVICES Public Health Service January 13, 2016 Food and Drug Administration 10903 New Hampshire Avenue Document Control Center - WO66-G609 Silver Spring, MD 20993-0002 Texas
Interventional Fluoroscopy
NATIONAL CANCER INSTITUTE THE SOCIETY OF INTERVENTIONAL RADIOLOGY Interventional Fluoroscopy Reducing Radiation Risks for Patients and Staff CONTENTS Introduction 1 Increasing use and complexity of interventional
LAP-BAND System Access Port II Kit
LAP-BAND System Access Port II Kit DIRECTIONS FOR USE (DFU) Access Port Needle Access Port Priming Needle Access Port II End Plug Band Priming Needle Stainless Steel Connector Tubing LAP-BAND System Access
Monitoring of radiation dose using dose tracking software in a neurovascular intervention room
Monitoring of radiation dose using dose tracking software in a neurovascular intervention room Poster No.: ESI-0017 Congress: EuroSafe Imaging 2017 Type: EuroSafe Imaging Authors: H. Acton 1, K. James
Wireless Implantable Micromachined Pressure Sensors: Approach and Clinical Demonstration
The Problem: Abdominal Aortic Aneurysms (AAA) Wireless Implantable Micromachined Pressure Sensors: Approach and Clinical Demonstration Mark G. Allen School of Electrical and Computer Engineering Georgia
Urology and Women s Health
Urology and Women s Health GYNECOLOGIC SURGERY PRODUCT CATALOG Hysteroscopic Tissue Removal Endometrial Ablation Introduction The all-in-one Symphion System is designed to transform the way you remove
Novel technology for the surgical treatment of cerebrovascular diseases
SYⅣ- Utility of a novel surgical microscope laser light source and its application with integrated dual-image videoangiography (DIVA) Jun Sakuma, Taku Sato, Kyouichi Suzuki, Mudathir S Bakhit, Mazasumi
Company Update. 28 May REVA Medical, Inc.
Company Update 28 May 2015 6 Recent Milestones Q2 through Q4 2014 Developed Fantom (to offer the desired advancements for a second generation product) November 2014 Completed $25 million financing (warrants
SUBJECT: INTRAVENOUS SOLUTIONS AND ADMIXTURE I.V.SOLUTIONS
COALINGA STATE HOSPITAL NURSING POLICY AND PROCEDURE MANUAL SECTION - Medications POLICY NUMBER: 519 Effective Date: August 31, 2006 SUBJECT: INTRAVENOUS SOLUTIONS AND ADMIXTURE I.V.SOLUTIONS 1. DEFINITION:
THE OPTIONAL ALN VENA CAVA FILTER
ALN VENA CAVA FILTERS INTENDED TO BE RETRIEVABLE AT ANY TIME THE OPTIONAL ALN VENA CAVA FILTER PERMANENT AND/OR TEMPORARY Prevention of thrombus migration Proven clinical effectiveness High performance
An Arteriovenous Malformation Model for Testing Liquid Embolic Materials
An Arteriovenous Malformation Model for Testing Liquid Embolic Materials Sangsoo Park, Hisook Yoon, Dae Chul Suh, and Ho-Young Song Summary: An arteriovenous malformation model with a transparent nidus
Guide for Cleaning, Sterilization and Storage of Introducers for Caldera Medical Implants
Guide for Cleaning, Sterilization and Storage of Introducers for Caldera Medical Implants M Manufactured by: Caldera Medical, Inc. 5171 Clareton Drive Agoura Hills, CA 91301 U.S. Toll Free: 866-4-CALDERA
Ordering information Metis Blue. Metis Green
Ordering information Metis Blue METIS BLUE CORONARY GUIDE WIRE - 185 CM - 5 UNITS PER BOX Metis Blue 0.014 185 cm Shaping Ribbon STR Floppy 0.6 CGW185S-0S Metis Blue 0.014 185 cm Shaping Ribbon STR Supersoft
Yukon Choice 4 DES Translumina - Allows natural healing
Coronary Stent System for Drug Application Translumina - Allows natural healing Allows natural healing Clinical history of the Yukon Stent Excellent clinical results with the Rapamycin Yukon Stent Dose-finding
Symphion 6.3 Endoscope
For single use only. Do not reuse. Federal (US) law restricts this device to sale by or on the order of a physician. PREFACE Symphion 6.3 Endoscope Instructions for Use This manual provides the information
Clinical Applications. ImagingRite. Neuro Intervention. 1 ImagingRite
Clinical Applications ImagingRite Neuro Intervention 1 ImagingRite ImagingRite, a comprehensive suite of imaging tools offered with Infinix -i angiographic systems, was designed to assist clinicians in
Cre8 TM BTK polymer-free DES technology: the Activ8 clinical trial
Cre8 TM BTK polymer-free DES technology: the Activ8 clinical trial Enrico Maria Marone Vascular Surgery - - San Raffaele ScientificInstitute, Milan - Italy Disclosure Speaker name: Enrico Maria Marone
Atherectomy as Primary Therapy for Lower Extremity Artery Disease: What will Be its Role in the Drug-Eluting Era
Atherectomy as Primary Therapy for Lower Extremity Artery Disease: What will Be its Role in the Drug-Eluting Era John R. Laird Professor of Medicine Medical Director of the Vascular Center UC Davis Medical
Failed thrombolysis in a 56-year-old aphasic and hemiplegic patient, what s next?
www.edoriumjournals.com CLINICAL IMAGES PEER REVIEWED OPEN ACCESS Failed thrombolysis in a 56-year-old aphasic and hemiplegic patient, what s next? Laurence Gauquelin, Marie-Ève Audet, Marie-Christine
Instructions for Use Reprocessed Balloon Inflation Devices
Reprocessed by Instructions for Use Reprocessed Balloon Inflation Devices Reprocessed Device for Single Use Caution: Federal (U.S.A.) law restricts this device to sale by or on the order of a physician.
Computer-Aided Surgical Navigation Coding Guide Neurosurgery. May 1, 2009
Computer-Aided Surgical Navigation Coding Guide Neurosurgery May 1, 2009 Please direct any questions to: Kim Brew Manager, Reimbursement and Therapy Access Medtronic Surgical Technologies (904) 279-7569
NeuroPort Array PN 4382, 4383, 6248, and 6249 Instructions for Use
630 Komas Drive Suite 200 Salt Lake City UT 84108 USA P +1 801.582.5533 F +1 801.582.1509 www.blackrockmicro.com NeuroPort Array PN 4382, 4383, 6248, and 6249 Instructions for Use Revision 2.00 / LB-0612
in Film Nitinol: nique Biomaterial for Next Generation dovascular Devices
in Film Nitinol: nique Biomaterial for Next Generation dovascular Devices Colin P Kealey MD Vice President, Advanced Development - NeuroSigma Inc. Biointerface Conference, September 2015 Scottsdale, Arizona
Guide for Cleaning, Sterilization and Storage of Reusable Introducers
Guide for Cleaning, Sterilization and Storage of Reusable Introducers M Manufactured by: Caldera Medical, Inc. 5171 Clareton Drive Agoura Hills, CA 91301 U.S. Toll Free: 866-4-CALDERA Telephone: 818-879-6555
Changing the Trajectory of Atrial Fibrillation and Stroke Shlomi Nachman
Changing the Trajectory of Atrial Fibrillation and Stroke Shlomi Nachman Company Group Chairman, Interventional Solutions & Specialty Surgery Cautions Concerning Forward-looking Statements These presentations
Head Fixation Using a Vac-Lok Cushion during Neuroendovascular Therapy
Journal of Neuroendovascular Therapy 2016; 10: 116 120 Online June 10 2016 DOI: 10.5797/jnet.oa.2016-0021 Head Fixation Using a Vac-Lok Cushion during Neuroendovascular Therapy Daisuke Uesaka, 1 Akinori
Interventional Tumor Therapy Minimally Invasive, Maximally Effective
Cover Story Interventional Oncology Interventional Tumor Therapy Minimally Invasive, Maximally Effective There is a continuous expansion of indications for interventional therapies in oncology. Thanks
Merit Medical s Innovative Family. of Vascular Access Products. A Great Introduction
Merit Medical s Innovative Family of Vascular Access Products A Great Introduction Sheath Introducers The Prelude family of sheath introducers is a comprehensive product line offering excellent transitions,
Emilio Calabrese MD National Center for Limb Salvage Pavia Italy International Center for Limb Salvage
Emilio Calabrese MD National Center for Limb Salvage Pavia Italy International Center for Limb Salvage www.gfmer.ch/icls/homepage.htm 5.11.2008 Emilio Calabrese MD Assessing CO 2 Toxicity ANIMAL STUDIES