1 SECTION INSULATED METAL WALL PANELS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this Section. 1.2 SUMMARY A. Section Includes: 1. Foamed-insulation-core metal wall panels. 2. Laminated-fire-resistant metal wall panels. 3. Laminated-insulation-core metal wall panels. 1.3 PREINSTALLATION MEETINGS A. Pre-bid Conference: Conduct conference at Kodiak AST Post & Kodiak 2921 # A Mill Bay Road, Kodiak Alaska Thursday January 23, 2014 at 1:30 p.m. 1.4 ACTION SUBMITTALS A. Product Data: For each type of product. B. LEED Submittals: 1. EA Energy and Atmosphere a. EA Credit 1: Optimize Energy Performance. 1) Demonstrating percentage of performance improvement that meets or surpasses ASHRAE/IESNA Standard EA Credit 2: Minimum Energy Performance 3. MR Material and Resource a. MR Credit 1.1 & 1.2: Building Reuse 1) Maintain Existing Walls, Floors & Roof 2) Maintain Interior Non-Structural Elements b. MR Credit 3: Materials Reuse c. MR Credit 4: Recycled Content INSULATED METAL WALL PANELS

2 1) Percentage weight of post-consumer and pre-consumer recycled content use materials with recycled content. 2) Recycled content value of product assembly by weight. 3) Indicate total value (cost) of each product used. 4. MR Credit 6: Rapidly Renewable Materials 5. IEQ Indoor Environmental Quality a. IEQ Credit 4.1: Low-Emitting Materials Adhesives and Sealants 1) Product data on adhesives and sealants to comply with standards for South Coast Air Quality Management District rule # ) Product data for paint and coatings having no VOC's 6. ID- Innovation in Design: C. Shop Drawings: a. ID Credits 1.1 to Include elevations, fastening patterns, and sections of each condition. 2. Include material type, metal thickness, paint finish, and manufacturer's installation suggestions. D. Panel Samples: Submit 1 ft - 0 in (30.48 cm) by full width sample panel indicating the metal, texture, and finish proposed. 1.5 INFORMATIONAL SUBMITTALS A. Product test reports. B. Warranties: Samples of special warranties. 1.6 QUALITY ASSURANCE A. Installer Qualifications: Installed by a contractor with a minimum of five (5) years experience with this type of construction, and documentation indicating successful completion of contracts for projects of similar size, scope and materials. B. Manufacturer Qualifications: Manufacturer s production and quality processes are inspected on a quarterly basis by third party quality control auditing programs through Factory Mutual, Underwriter Laboratories, and Intertek Testing Services. Quality control manuals for each accreditation agency are in place detailing the production and quality processes and methods used in the manufacturing of product. 1.7 DELIVERY, STORAGE, AND HANDLING INSULATED METAL WALL PANELS

3 A. Protect products of metal panel system during shipping, handling, and storage to prevent staining, denting, deterioration of components, or other damage. B. Deliver, unload, store, and erect metal panels and accessory items in a manner to prevent bending, warping, twisting, and surface damage. C. Store panels in accordance with manufacturer's written instructions. D. Shield foam-insulated metal wall panels from direct sunlight until installation. E. Store products off the ground, with panels sloped for drainage and covered to protect factory finishes from damage. Stack bundles no more than two high. 1.8 WARRANTY A. Warranty: Manufacturer's written limited warranty providing panels to be free from defects in materials and workmanship, excluding coil coatings (paint finishes) that are covered under separate warranty. 1. Warranty Period: Two years from date of Substantial Completion. B. Warranty on Panel Finishes: Manufacturer's standard form in which manufacturer agrees to repair finish or replace metal panels that show evidence of deterioration of factory-applied finishes within specified warranty period. 1. Finish Warranty Period: a. 40 year limited warranty on the exterior paint finish for adhesion to the metal. substrate b. 30 year limited warranty on the exterior paint finish for chalk and fade. PART 2 - PRODUCTS 2.1 PERFORMANCE REQUIREMENTS A. Recycled Content of Steel Products: Postconsumer recycled content plus one-half of preconsumer recycled content not less than 25 percent. B. Structural Performance: Provide metal panel systems capable of withstanding the effects of the following loads, based on testing according to ASTM E 72: 1. Wind Loads: Verified using a 20 psf simulated wind load. 2. Deflection Limits: For wind loads, no greater than 1/180 for exterior wall panels and 1/120 for partition and liner walls. 3. Large Missile Impact Test: Conducted in accordance with ASTM E 1886 and ASTM E INSULATED METAL WALL PANELS

4 C. Air Infiltration: Air leakage of not more than 0.06 cfm/sq. ft. (0.3 L/s per sq. m). Air infiltration shall not exceed 0.01 cfm/sq. ft (0.05 L/s per sq. m) at 6.24 psf (.30 kpa), and 0.04 cfm/ sq. ft (0.2 L/s per sq. m) of wall area] when tested according to ASTM E 283 at a static pressure of 12 psf (.576 kpa). D. Static Water Penetration: There shall be no uncontrolled water penetration through the panel joints at a static pressure of 20 psf (.96 kpa) when tested in accordance with ASTM E 331. E. Dynamic Water Penetration: There shall be no uncontrolled water penetration through the panel joints when subjected to a 95 mph slip stream air flow and application of water for a 15 minute period in accordance with AAMA F. Condensation Resistance Factor: The minimum condensation resistance factor of the panel shall be 92 when tested in general accordance with AAMA G. Thermal Performance: Panels shall provide a K-factor of 0.14 btu/sf/hr/deg F at a 75 deg F (mean temperature when tested in accordance with ASTM C 518. H. Fire Test Response Characteristics: 1. Surface Burning Characteristics: The insulated core shall have been tested in accordance with ASTM E 84 for surface burning characteristics. The core shall have a maximum flame spread of 25 and a smoke developed rating of Factory Mutual Research Corporation (FMRC) Standard 4880: Panel assembly shall not support a self-propagating fire which reaches any limits of the 50 foot high corner test structure as evidenced by flaming or material damage of the ceiling of the assembly. 3. Fire Propagation: The fire assembly shall meet the requirements of the standard for NFPA 285 and NFPA 286. Heat potential shall be determined using NFPA 259 Test Method for Potential Heat of Building Materials. 4. Canadian Certifications Flame spread: Evaluation of fire spread over the exterior surface shall be conducted and in compliance with CAN/ULC S IBC Chapter 26: Panel performance under the above test methods, shall meet the requirements of IBC, Chapter on foam plastics. 6. Laminated Fire-Resistive Metal Panel, Fire Resistance Data: a. Finished panel in a 4 in thickness shall meet the requirements of a one (1) hour fire resistance rating for non- load bearing wall in accordance with UL 263 (per UL design U050 for US and design W021 for Canada), ASTM E119 and CAN/ULC S101 (per Intertek design MS/WA 60-1). b. 1 and 2 hour fire rated wall panels shall meet the requirements of Fire Door and Window Assemblies as listed by UL in accordance with UL 9, CAN4-S106 and UBC Standard 7-4 ( per UL designs SP and WA ) 2.2 FOAMED-INSULATION-CORE METAL WALL PANELS A. General: Provide factory-formed and -assembled metal wall panels fabricated from two rollformed metal facing sheets chemically bonded to insulation core foamed in place during fabrication, and with joints between panels designed to form weather tight seals. Include accessories required for weather tight installation. INSULATED METAL WALL PANELS

5 1. Panel Performance: Kodiak AWT Hangar, Kodiak Airport Alaska, a. Freeze/Heat Cycling: No delamination, surface blistering, or permanent bowing when subjected to cyclic temperature extremes of -20 deg F to +180 deg F for 21 eight hour cycles. b. Humid Aging: Volume increase not greater than 6.0 percent and no delamination or metal corrosion when tested for seven days at 140 deg F and 100 percent relative humidity according to ASTM D c. Fatigue: No evidence of delamination, core cracking, or permanent bowing when tested to a 20-lbf/sq. ft. positive and negative wind load and with deflection of L/180 for 2 million cycles. d. Autoclave: No delamination when exposed to 2-psi pressure at a temperature of 212 deg F for 2-1/2 hours. 2. Insulation Core: Polyurethane foam using a non-cfc blowing agent, with maximum flame-spread and smoke-developed indexes of 25 and 450, respectively. a. Closed-Cell Content: 92 percent when tested according to ASTM D b. Density: 2.0 to 2.6 lb/cu. ft. when tested according to ASTM D c. Compressive Strength: Minimum 20 psi when tested according to ASTM D d. Shear Strength: 26 psi when tested according to ASTM C 273/C 273M. B. Concealed-Fastener, Foamed-Insulation-Core Metal Wall Panels CF42: Formed with tongueand-groove panel edges; designed for sequential installation by interlocking panel edges and mechanically attaching panels to supports using concealed clips or fasteners. 1. Basis-of-Design Product: Subject to compliance with requirements, provide Metl-Span LLC product named or comparable product by one of the following: a. CENTRIA Architectural Systems. b. Firestone Building Products. c. King Span LLC 2. Profiled Wall Panels: Metl-Span CF concealed fastener wall panel: a. CF-42 Wall Panel, 42 in module width, with Mesa profiled face with a Light Mesa profiled liner. 1) Thickness: 4 in. 3. Thermal-Resistance Value (R-Value): R-32 according to ASTM C Materials: a. Exterior Face: G-90 galvanized steel conforming to ASTM A 653 and/or prefinished AZ50 aluminum-zinc coated steel conforming to ASTM A 792, minimum grade 33 with stucco embossed texture. 1) Thickness: 24 Ga. INSULATED METAL WALL PANELS

6 b. Interior Liner: G-90 galvanized steel conforming to ASTM A 653 and/or AZ50 aluminum-zinc coated steel conforming to ASTM A 792, minimum grade 33, with stucco embossed texture. 1) Thickness: 26 Ga. c. Foam Core: Continuously foamed-in-place, zero ODP and zero VOC closed cell polyurethane. d. Flashing and Trim: 5. Finishes: 1) Provide complete insulated metal wall panel assembly incorporating trim and miscellaneous flashings. Provide required fasteners, clips, closures, tapes, and sealants. 2) Flashing and trim shall be brake-formed sheet metal in the same thickness and finish to match panels. a. Exterior face sheet: 1) Base Primer: Nominal 0.2 mil. 2) Finish Coat: Nominal 0.7 mil full strength 70 percent PVDF Fluoropolymer coating in manufacturer's standard colors. b. Interior Sheet: 6. Side Connections: 1) Primer: Nominal 0.2 mil primer. 2) Finish Coat: Nominal 0.7 mil polyester coating in USDA compliant Igloo White. a. CF-42 wall panel shall have offset double tongue and groove joinery with an extended metal shelf allowing fasteners to penetrate both metal faces with clips concealed in the side joint. 7. Sealants: a. All sealants shall be field applied to ensure vapor and water tightness. 2.3 FABRICATION A. General: Fabricate and finish metal panels and accessories at the factory, by manufacturer's standard procedures and processes, as necessary to fulfill indicated performance requirements demonstrated by laboratory testing. Comply with indicated profiles and with dimensional and structural requirements. B. Provide panel profile, including major ribs and intermediate stiffening ribs, if any, for full length of panel. INSULATED METAL WALL PANELS

7 C. Fabricate metal panel joints with factory-installed captive gaskets or separator strips that provide a weather tight seal and prevent metal-to-metal contact, and that minimize noise from movements. D. Sheet Metal Flashing and Trim: Fabricate flashing and trim to comply with manufacturer's recommendations and recommendations in SMACNA's "Architectural Sheet Metal Manual" that apply to design, dimensions, metal, and other characteristics of item indicated. 2.4 FINISHES A. Panels and Accessories: 1. Two-Coat Fluoropolymer: Fluoropolymer finish containing not less than 70 percent PVDF resin by weight in color coat. Prepare, pretreat, and apply coating to exposed metal surfaces to comply with coating and resin manufacturers' written instructions. PART 3 - EXECUTION 3.1 EXAMINATION A. Examine all structural steel before beginning installation to insure that all supporting members are straight, level, plumb and satisfactory for panel installation. B. Intermediate framing member (secondary structural supports) alignment tolerances required, as specified below: 1. 0 to ¼ inch outward of the actual wall framing plane for members at 10 ft or greater spacing. C. Do not begin installation until unsatisfactory conditions are corrected. D. Beginning of installation shall signify the structure and adjacent conditions as being proper and acceptable. 3.2 PREPARATION A. Miscellaneous Supports: Install sub-framing, furring, and other miscellaneous panel support members and anchorages according to ASTM C 754 and metal panel manufacturer's written recommendations. 3.3 INSULATED METAL WALL PANEL INSTALLATION A. General: Apply continuous ribbon of sealant to panel joint on concealed side of insulated metal wall panels as vapor seal; apply sealant to panel joint on exposed side of panels for weather seal. INSULATED METAL WALL PANELS

8 1. Fasten foamed-insulation-core metal wall panels to supports with fasteners at each lapped joint at location and spacing and with fasteners recommended by manufacturer. 2. Apply panels and associated items true to line for neat and weather tight enclosure. Avoid "panel creep" or application not true to line. 3. Provide metal-backed washers under heads of exposed fasteners on weather side of insulated metal wall panels. 4. Locate and space exposed fasteners in uniform vertical and horizontal alignment. Use proper tools to obtain controlled uniform compression for positive seal without rupture of washer. 5. Provide sealant tape at lapped joints of insulated metal wall panels and between panels and protruding equipment, vents, and accessories. 6. Apply a continuous ribbon of sealant tape to panel side laps and elsewhere as needed to make panels weather tight. 7. Apply snap-on battens to exposed-fastener, insulated-core metal wall panel seams to conceal fasteners. B. Foamed-Insulation-Core Metal Wall Panels: Fasten metal wall panels to supports with concealed clips at each joint at location and spacing and with fasteners recommended by manufacturer. Fully engage tongue and groove of adjacent panels. 1. Install clips to supports with self-tapping fasteners. C. Accessory Installation: Install accessories with positive anchorage to building and weather tight mounting, and provide for thermal expansion. Coordinate installation with flashings and other components. D. Flashing and Trim: Comply with performance requirements, manufacturer's written installation instructions, and SMACNA's "Architectural Sheet Metal Manual." Provide concealed fasteners where possible, and set units true to line and level. Install work with laps, joints, and seams that are permanently watertight. 3.4 FIELD QUALITY CONTROL A. Panel installer shall inspect and approve each completed wall area and shall be responsible for protection of completed work from damage by other trades. 3.5 CLEANING A. Remove temporary protective coverings and strippable films before exposure to sunlight. B. Wipe finished surfaces clean of any filings caused by drilling or cutting to prevent rust staining. C. Replace metal panels that have been damaged or have deteriorated beyond successful repair by finish touchup or similar minor repair procedures. END OF SECTION INSULATED METAL WALL PANELS

Guide Specifications. Metl-Span Architectural Insulated Metal Panel For Commercial & Industrial Buildings PART 1 GENERAL

Guide Specifications. Metl-Span Architectural Insulated Metal Panel For Commercial & Industrial Buildings PART 1 GENERAL Guide Specifications 2012 Master Format Section 07 42 13.19 Metl-Span Architectural Insulated Metal Panel For Commercial & Industrial Buildings PART 1 GENERAL 1.1 Work Included A. Pre-insulated metal panel

More information

Alply CLASSIC WALL Architectural Insulated Panel Wall System

Alply CLASSIC WALL Architectural Insulated Panel Wall System SECTION 07 42 13 INSULATED METAL WALL PANELS ALPLY Insulated Panels Alply CLASSIC WALL Architectural Insulated Panel Wall System PART 1 / GENERAL 1.1 SYSTEM DESCRIPTION A. Smooth, non-embossed steel, insulated

More information

SECTION COMPOSITE METAL WALL PANEL SYSTEM (Accu-Trac Low Profile DS)

SECTION COMPOSITE METAL WALL PANEL SYSTEM (Accu-Trac Low Profile DS) SECTION 07412 COMPOSITE METAL WALL PANEL SYSTEM (Accu-Trac Low Profile DS) PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions

More information

CS-100 Guide Specifications

CS-100 Guide Specifications MANUFACTURER CUSTOM-BILT METALS 1333 Corporate Drive, Suite 103 Irving, Texas 75038-2520 (800) 826-7813 or info@custombiltmetals.com www.custombiltmetals.com CS-100 Guide Specifications This Guide Specification

More information

SL150 Guide Specification

SL150 Guide Specification SL150 Guide Specification This is a suggested guide specification for metal roofing projects where the SL150 panel system is applicable. Questions regarding applicability should be discussed with Union

More information

PROJECT LOCATION SECTION COPPER METAL PLATE WALL PANELS

PROJECT LOCATION SECTION COPPER METAL PLATE WALL PANELS SECTION 07 4213.25 PART 1- GENERAL 1.01 SECTION INCLUDES A. Copper metal plate wall panels. 1.02 RELATED REQUIREMENTS A. Section 05 4000 Cold-Formed Metal Framing: Wall panel substrates support framing.

More information

1. Include similar Samples of trim and accessories involving color selection.

1. Include similar Samples of trim and accessories involving color selection. SECTION 074116- INSULATED METAL ROOF PANELS PART 1 - GENERAL 1.1 RELATED DOCUMENTS Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

SECTION SLOPED TRANSLUCENT METAL SKYLIGHT SYSTEM

SECTION SLOPED TRANSLUCENT METAL SKYLIGHT SYSTEM PART 1- GENERAL 1.1 SUMMARY A. Section Includes: SECTION 084523 - SLOPED TRANSLUCENT METAL SKYLIGHT SYSTEM 1. Flat factory prefabricated structural insulated translucent sandwich panels; with glazed endwalls.

More information

SPECIFICATIONS FOR AluSystems Aluminum Composite Panels Series 20 Dry Joint 1.00 GENERAL 1.01 RANGE OF WORK Section includes: Laminated panels and attachment systems for use as exterior cladding. A. Provide

More information

SECTION ALUMINUM COMPOSITE MATERIAL WALL PANELS. A. Section includes aluminum composite material wall panels.

SECTION ALUMINUM COMPOSITE MATERIAL WALL PANELS. A. Section includes aluminum composite material wall panels. 1/11 SECTION 074213.23 - ALUMINUM COMPOSITE MATERIAL WALL PANELS PART 1 - GENERAL 1.1 SUMMARY A. Section includes aluminum composite material wall panels. 1.2 PRE-INSTALLATION MEETINGS A. Pre-installation

More information

Guide Specification SDP 200

Guide Specification SDP 200 PART 1 GENERAL 1.01 SUMMARY A. Section Includes: Sheet metal roofing panels, metal trim, accessories, fasteners, closures, and sealants. [Specifier Note: Edit paragraph below to suit project requirements.]

More information

Specifiers: Click on the icon in the WORD toolbar to reveal detailed instructions

Specifiers: Click on the icon in the WORD toolbar to reveal detailed instructions Specifiers: Click on the icon in the WORD toolbar to reveal detailed instructions SECTION 07 41 00 ROOF PANELS Kingspan Insulated Panels KingZip Pre-Insulated Standing Seam Metal Roof Panels PART 1 - GENERAL

More information

Page 1 of 5

Page 1 of 5 SPECIFICATIONS COMPOSITE MATERIAL PANEL SYSTEM ESTOLGA 1000 DRY SEAL SYSTEM PART 1 GENERAL 1.01 SECTION INCLUDES A. Exterior cladding consisting of formed metal composite material (MCM) sheet, secondary

More information

1.1 SECTION INCLUDES A. Insulated Metal and FRP Wall and Ceiling Panels and Related Accessories.

1.1 SECTION INCLUDES A. Insulated Metal and FRP Wall and Ceiling Panels and Related Accessories. Permatherm Specification SECTION 07435 (CSI MasterFormat 1995) SECTION 07 42 43 (CSI MasterFormat 2004) SECTION 07 42 13.19 (CSI MasterFormat 2012) INSULATED METAL and FRP WALL PANELS Part 1: General General:

More information

Corium Brick Rainscreen System Specifications

Corium Brick Rainscreen System Specifications CORIUM BRICK RAINSCREEN SYSTEM PART 1 - GENERAL 1.1 SUMMARY A. Work Included: The Work of this Section shall include but not be limited to the following: 1. Corium brick plates 2. Galvanized and coated

More information

Metl-Span ThermalSafe Insulated Metal Wall and Ceiling Panels

Metl-Span ThermalSafe Insulated Metal Wall and Ceiling Panels Insulated Metal Wall and Ceiling Panels Metl-Span's ThermalSafe insulated metal wall and ceiling panels (IMP) are developed to protects against fire penetration. Unlike traditional wall materials, this

More information

SECTION MANUFACTURED ROOF EXPANSION JOINTS

SECTION MANUFACTURED ROOF EXPANSION JOINTS SECTION 07 71 29 - MANUFACTURED ROOF EXPANSION JOINTS PART 1 -GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

SECTION INSULATED METAL WALL PANELS. ATAS International, Inc. General Specification for Commercial/Industrial and Architectural Applications

SECTION INSULATED METAL WALL PANELS. ATAS International, Inc. General Specification for Commercial/Industrial and Architectural Applications SECTION 07 42 13 INSULATED METAL WALL PANELS ATAS International, Inc. General Specification for Commercial/Industrial and Architectural Applications PART 1 GENERAL 1.1. Summary The contract drawings indicate

More information

Guideline Specifications

Guideline Specifications Page 1 of 7 PART 1 Guideline Specifications Exterior Aluminum/Composite Wall Panels GENERAL ARROWHEAD 508 SYSTEM Pressure Equalized Rainscreen SECTION 07410 1.01 SUMMARY A. Work of this section included

More information

Specifications for FL-100 Soffit Panel

Specifications for FL-100 Soffit Panel Union Corrugating Company Specifications for FL-100 Soffit Panel SECTION 07410 METAL SOFFIT PANELS PART 1 GENERAL 1.1 DESCRIPTON A. Section Includes: 1. Preformed metal soffit panel system 2. Associated

More information

ST. JOHNS COUNTY ARCH. PROJ. NO SECTION PREFABRICATED ALUMINUM CANOPIES PART 1 - GENERAL 1.1 RELATED DOCUMENTS

ST. JOHNS COUNTY ARCH. PROJ. NO SECTION PREFABRICATED ALUMINUM CANOPIES PART 1 - GENERAL 1.1 RELATED DOCUMENTS SECTION 10530 PREFABRICATED ALUMINUM CANOPIES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification

More information

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ROOFING AND SIDING PANELS REPORT HOLDER: KINGSPAN INSULATED PANELS, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ROOFING AND SIDING PANELS REPORT HOLDER: KINGSPAN INSULATED PANELS, INC. 0 Most Widely Accepted and Trusted ICC-ES Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-1143 Reissued 04/2017 This report is subject to renewal 04/2018. DIVISION: 07 00 00 THERMAL

More information

METL-SPAN Insulated Concealed Fastener (CF) Metal Wall Panels

METL-SPAN Insulated Concealed Fastener (CF) Metal Wall Panels Page 1 of 24 METL-SPAN Insulated Concealed Fastener (CF) Metal Wall Panels Metl-Span Insulated Metal Panels (IMPs) consist of two single-skin metal facings and a factory-foamedin-place core. Metl-Span

More information

SECTION EXTERIOR GRILLS AND SCREENS

SECTION EXTERIOR GRILLS AND SCREENS SECTION 10 82 13 PART 1 GENERAL PART 1 1 SUMMARY A. Section Includes: 1. Exterior perforated aluminum screen wall system with Ombrae TM Optical Tile imaging technology. 2. Accessories including attachments,

More information

SECTION METAL ROOF PANELS

SECTION METAL ROOF PANELS SECTION 07 41 13 PART 1 GENERAL 1.1 SECTION INCLUDES A. Standing-seam roof panels. B. Metal roofing accessories. 1.2 RELATED SECTIONS A. Section 07 62 00 - Sheet Metal Flashing. B. Section 07 72 00 - Roof

More information

Specifiers: Click on the icon in the WORD toolbar to reveal detailed instructions

Specifiers: Click on the icon in the WORD toolbar to reveal detailed instructions Specifiers: Click on the icon in the WORD toolbar to reveal detailed instructions (Specifier Note: The purpose of this guide specification is to assist the specifier in correctly specifying perforated

More information

Metl-Span Insulated BattenLok Metal Roof Panels

Metl-Span Insulated BattenLok Metal Roof Panels Metal Roof Panels Insulated BattenLok (IBL) is one of Metl-Span s popular insulated standing seam metal roof panels. The IBL panel is ideal for architectural, commercial, industrial, institutional and

More information

SECTION FIBERGLASS REINFORCED POLYMER (FRP) PANELS

SECTION FIBERGLASS REINFORCED POLYMER (FRP) PANELS SECTION 07 44 50 FIBERGLASS REINFORCED POLYMER (FRP) PANELS PART 1 - GENERAL 1.1 SECTION INCLUDES A. Design, Engineering, manufacturing and erection of fiberglass reinforced panels. Delegated Design of

More information

PROJECT LOCATION SECTION TEXTURED METAL PLATE WALL PANELS

PROJECT LOCATION SECTION TEXTURED METAL PLATE WALL PANELS SECTION 07 4213.29 PART 1 - GENERAL 1.01 SECTION INCLUDES A. Textured, aluminum metal plate wall panels. 1.02 RELATED REQUIREMENTS A. Section 05 4000 Cold-Formed Metal Framing: Wall panel substrates support

More information

by Rollfab Metal Products

by Rollfab Metal Products by Rollfab Metal Products SECTION 07460 ALUMINUM SIDING AND SOFFITS PART 1 GENERAL 1.2 RELATED SECTIONS 1.3 REFERENCES A. SECTION INCLUDES B. Aluminum Siding. C. Aluminum Soffits. D. Aluminum trim and

More information

SECTION ALUMINUM WINDOWS

SECTION ALUMINUM WINDOWS SECTION 08520 ALUMINUM WINDOWS PART 1 - GENERAL 1.01 SUMMARY A. Section includes: 1. Storefront systems and aluminum framed glass doors. 2. Hardware, fasteners, accessories, filler pieces, etc., required

More information

Louis Armstrong New Orleans International Airport NOAB Project # North Terminal Development Program Phase 1

Louis Armstrong New Orleans International Airport NOAB Project # North Terminal Development Program Phase 1 Louis Armstrong New Orleans International Airport NOAB Project # 8910-01233 PART 1 - GENERAL SECTION 07 71 29 - MANUFACTURED ROOF EXPANSION JOINTS 1.1 RELATED DOCUMENTS A. Drawings and general provisions

More information

Specifier Note: Revise paragraph below to suit project requirements. Add section numbers per CSI MasterFormat and specifier s practice.

Specifier Note: Revise paragraph below to suit project requirements. Add section numbers per CSI MasterFormat and specifier s practice. McElroy Metal, Inc. 1500 Hamilton Rd. Bossier City, LA 71111 Phone: (800) 562-3576 Phone: (318) 747-8097 Fax: (318) 747-8099 E-mail: info@mcelroymetal.com www.mcelroymetal.com This MANU-SPECª utilizes

More information

PROJECT LOCATION SECTION ZINC ALLOY METAL PLATE WALL PANELS

PROJECT LOCATION SECTION ZINC ALLOY METAL PLATE WALL PANELS SECTION 07 42 13.26 PART 1 - GENERAL 1.01 SECTION INCLUDES A. Zinc alloy metal plate wall panels. 1.02 RELATED REQUIREMENTS A. Section 05 4000 Cold-Formed Metal Framing: Wall panel substrates support framing.

More information

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL WALL PANELS REPORT HOLDER: METL SPAN, A DIVISION OF NCI GROUP, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL WALL PANELS REPORT HOLDER: METL SPAN, A DIVISION OF NCI GROUP, INC. 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 2218 Reissued 09/2017 This report is subject to renewal 09/2018. DIVISION: 07 00

More information

SECTION COPPER WALL PANELS. ***This section has been updated to IBC. Verify for specific project conditions.***

SECTION COPPER WALL PANELS. ***This section has been updated to IBC. Verify for specific project conditions.*** ***This section has been updated to IBC. Verify for specific project conditions.*** PART 1 GENERAL 1.1 SUMMARY ***Edit to project requirements*** A. Section Includes: 1. Clear copper and preweathered copper

More information

Metl-Span Exposed Fastener Metal Wall Panels

Metl-Span Exposed Fastener Metal Wall Panels Exposed Fastener Metal Wall Panels manufactures metal panels with the most technologically advanced manufacturing line in the United States. Our metal panel color and applied finish offerings allow for

More information

SECTION Structured Polycarbonate Panel Assemblies. Series 3500 BPC System with 40mm Tongue and Groove

SECTION Structured Polycarbonate Panel Assemblies. Series 3500 BPC System with 40mm Tongue and Groove Duo-Gard Industries Inc. 40442 Koppernick Road Canton, Michigan 48187 Phone (734) 207-9700 Fax (734) 207-7995 www.duo-gard.com SECTION 08 45 13 Structured Polycarbonate Panel Assemblies Series 3500 BPC

More information

Code Compliance Research Report CCRR-0228

Code Compliance Research Report CCRR-0228 Code Compliance Research Report CCRR-0228 Issue Date: 05-09-2017 Renewal Date: 05-11-2018 Revision Date: 06-23-2017 DIVISION: 07 00 00 THERMAL AND MOISTURE PROTECTION Section: 07 40 00 Roofing and Siding

More information

Prestige Series Guide Specifications

Prestige Series Guide Specifications Prestige Series Guide Specifications MANUFACTURER AEP SPAN www.aepspan.com info@aepspan.com 800-733-4955 Prestige Series is a metal panel for exterior and interior walls, fascias and equipment screen applications.

More information

SECTION EXPANSION CONTROL

SECTION EXPANSION CONTROL SECTION 07 95 00 PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply

More information

General Overview SECTION PBR & R PANEL - PREFORMED ROOF AND WALL PANELS

General Overview SECTION PBR & R PANEL - PREFORMED ROOF AND WALL PANELS SECTION 07410 - PREFORMED ROOF AND WALL PANELS # Specifier: Notation (#) means that text following is a specifier s note or sample. PART 1 - GENERAL 1.01 Description # Specifier: Do not alter paragraph

More information

Metal Roof Panels

Metal Roof Panels University of New Hampshire University of New Hampshire Scholars' Repository Division 07 Thermal and Moisture Protection Chapter 5 Technical Construction and Renovation Standards 1-25-2013 074113 - Metal

More information

EVO ALUMINUM COMPOSITE METAL (ACM) WALL PANEL SPECIFICATION

EVO ALUMINUM COMPOSITE METAL (ACM) WALL PANEL SPECIFICATION SECTION 07 42 43 EVO ALUMINUM COMPOSITE METAL (ACM) WALL PANEL SPECIFICATION SPEC NOTE: Optional text is indicated by square brackets []. Delete unwanted items and square brackets in final specification.

More information

Centria Conversion SECTION METAL WALL PANELS AMERICAN ARCHITECTURAL MANUFACTURERS ASSOCIATION (AAMA)

Centria Conversion SECTION METAL WALL PANELS AMERICAN ARCHITECTURAL MANUFACTURERS ASSOCIATION (AAMA) SECTION 07 42 13.03 METAL WALL PANELS PART 1 GENERAL 1.1 REFERENCES AMERICAN ARCHITECTURAL MANUFACTURERS ASSOCIATION (AAMA) AAMA 620 AAMA 621 Voluntary Specification for High Performance Organic Coatings

More information

CENTRIA FORMABOND II Metal Composite Wall System

CENTRIA FORMABOND II Metal Composite Wall System CENTRIA FORMABOND II Metal Composite Wall System CENTRIA FormaBond II is the only true metal composite panel wall system designed, manufactured and fabricated by a single, reliable national manufacturer

More information

Ceco LS-36 Wall and Roof Insulated Metal Panel

Ceco LS-36 Wall and Roof Insulated Metal Panel Insulated Metal Panel Ceco's LS-36 panels offer versatility for roof and wall applications for a wide range of architectural, commercial and industrial applications. Energy-efficient LS-36 panels provide

More information

SECTION METAL ROOFING MASTER SPECIFICATION

SECTION METAL ROOFING MASTER SPECIFICATION SECTION 07 41 13 METAL ROOFING MASTER SPECIFICATION PART I - GENERAL REQUIREMENTS 1.01 DESCRIPTION OF WORK: A. Section Includes: The extent of each type of preformed metal roofing panel as indicated on

More information

SECTION ALUMINUM STORM WINDOWS

SECTION ALUMINUM STORM WINDOWS PART 1 - GENERAL 1.1 DESCRIPTION: SECTION 08 51 69.11 ALUMINUM STORM WINDOWS SPEC WRITER NOTES: 1. Delete between // // if not applicable to project. 2. Also delete any other item or paragraph not applicable

More information

FIXED SERIES 6200 AAMA/WDMA/CSA 101/I.S.2/A Structural Performance: Thermal Break: Main Frame Depth: 3 1/4. Glazing Thickness (Maximum): 1

FIXED SERIES 6200 AAMA/WDMA/CSA 101/I.S.2/A Structural Performance: Thermal Break: Main Frame Depth: 3 1/4. Glazing Thickness (Maximum): 1 GUIDE SPECIFICATION Boyd Aluminum Manufacturing Company P.O. Box 1565 3248 E. Division Street Springfield, MO 65801-1565 800-737-2800 417-862-1232 fax boydaluminum.com FIXED SERIES 6200 AAMA/WDMA/CSA 101/I.S.2/A440-08

More information

LUX Specifications. Section S - Preformed Steel Siding

LUX Specifications. Section S - Preformed Steel Siding Part 1 General.1 System-1: Installation over building paper or air barrier membrane, on exterior grade gypsum board or exterior grade wood sheathing. 1.2 RELATED SECTIONS.1 Section 01 11 00 Summary of

More information

VITRABOND Aluminum Composite Panel Façade System Specification Template

VITRABOND Aluminum Composite Panel Façade System Specification Template VITRABOND Aluminum Composite Panel Façade System Specification Template SECTION 07 - COMPOSITE METAL WALL PANELS UTILIZING VITRABOND MATERIAL PART 1 GENERAL 1.1 SECTION INCLUDES A. Provide metal composite

More information

1.2.1 Section Cold-Formed Metal Framing: Metal framing for support of aluminum soffits.

1.2.1 Section Cold-Formed Metal Framing: Metal framing for support of aluminum soffits. 1 GENERAL 1.1 SECTION INCLUDES 1.1.1.1 Aluminum Siding. 1.1.1.2 Aluminum Soffits. 1.1.1.3 Thermally Broken Façade Sub-structure. 1.1.1.4 Aluminum trim and accessories. 1.2 RELATED SECTIONS 1.2.1 Section

More information

PRE-ENGINEERED METAL BUILDING SYSTEM

PRE-ENGINEERED METAL BUILDING SYSTEM PRE-ENGINEERED METAL BUILDING SYSTEM PART 1 GENERAL 1.1 SUMMARY A. The building shall include all primary and secondary structural framing members, connection bolts, roof and wall covering, flashing, gutter,

More information

SECTION EXPANSION CONTROL

SECTION EXPANSION CONTROL SECTION 07 95 00 PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply

More information

CENTRIA Intercept Entyre Preformed Metal Modular Panel Wall System

CENTRIA Intercept Entyre Preformed Metal Modular Panel Wall System CENTRIA Intercept Entyre Preformed Metal Modular Panel Wall System CENTRIA Intercept Entyre is a unique modular metal wall system designed, available from a reliable national manufacturer and supported

More information

A. Product Data: For each type of deck, accessory, and product indicated.

A. Product Data: For each type of deck, accessory, and product indicated. SECTION 053100 - PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Roof deck. 2. Composite floor deck. 3. Noncomposite form deck. 1.2 SUBMITTALS A. Product Data: For each type of deck, accessory, and

More information

Section PANEL SIGNAGE

Section PANEL SIGNAGE Section 10 14 23 PANEL SIGNAGE PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including FDOT DIVISION I GENERAL REQUIREMENTS & COVENANTS Specification Sections,

More information

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS SECTION: METAL WALL PANELS REPORT HOLDER:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS SECTION: METAL WALL PANELS REPORT HOLDER: 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 4 6587 (562) 699 0543 www.icc es.org ESR 3152 Reissued 08/2017 This report is subject to renewal 08/2018. DIVISION: 07 00 00

More information

Signature Series 5 Lap SECTION ALUMINUM WINDOWS

Signature Series 5 Lap SECTION ALUMINUM WINDOWS Signature Series 5 Lap SECTION 08 51 13 ALUMINUM WINDOWS PART 1 GENERAL 1.01 SUMMARY A. Related Documents: Conditions of the Contract, Division 1 - General Requirements, and Drawings apply to Work of this

More information

SECTION PROFILED METAL WALL PANEL SYSTEM

SECTION PROFILED METAL WALL PANEL SYSTEM MANUFACTURER Firestone Building Products 1001 Lund Boulevard Anoka, MN 55303-1089 Telephone: (800) 426-7737 or (763) 576-9595 FAX: (763) 576-9596 VR Classic Omega Profiled Panel PART 1 GENERAL SECTION

More information

REYNOBOND FR DURAGLOSS 5000 ECOCLEAN

REYNOBOND FR DURAGLOSS 5000 ECOCLEAN OCTOBER, 2014 REYNOBOND FR DURAGLOSS 5000 ECOCLEAN 1 SECTION 074213 FORMED METAL WALL PANELS This suggested guide specification has been developed using the current edition of the Construction Specifications

More information

(Specifier Note: Aristech Surfaces LLC is the manufacturer of the Avonite brand

(Specifier Note: Aristech Surfaces LLC is the manufacturer of the Avonite brand (Specifier Note: Aristech Surfaces LLC is the manufacturer of the Avonite brand The purpose of this guide specification is to assist the specifier in correctly specifying solid surface wall cladding, shower

More information

SECTION ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS PART 1 - GENERAL 1.1 SUMMARY. A. Section Includes:

SECTION ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS PART 1 - GENERAL 1.1 SUMMARY. A. Section Includes: SECTION 084113 - ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Exterior storefront framing. 2. Storefront framing for ribbon walls. 3. Storefront framing

More information

Architectural Single-Hung Aluminum Window Series L701T SH-AW130 GUIDE SPECIFICATION

Architectural Single-Hung Aluminum Window Series L701T SH-AW130 GUIDE SPECIFICATION Architectural Single-Hung Aluminum Window Series L701T SH-AW130 GUIDE SPECIFICATION Section 08520 Aluminum Windows PART 1: WORK INCLUDED A. The conditions of the contract and applicable sections of Division

More information

ACOUSTICAL WALL TREATMENT SECTION 09840

ACOUSTICAL WALL TREATMENT SECTION 09840 ACOUSTICAL WALL TREATMENT PART 1 GENERAL 1.1 SUMMARY A. Section Includes: Site-fabricated, stretched fabric acoustical wall system built with rigid polymer stretching system to secure fabric over the wall

More information

COLLEGE CLASSROOM & DORMITORY SPECIFICATION SECTION 08100

COLLEGE CLASSROOM & DORMITORY SPECIFICATION SECTION 08100 COLLEGE CLASSROOM & DORMITORY SPECIFICATION SECTION 08100 Part 1 General 1.01 Work Included A. The work under this section shall include the furnishing of all items shown on the drawings and as specified,

More information

Specifiers: Click on the icon in the WORD toolbar to reveal detailed instructions

Specifiers: Click on the icon in the WORD toolbar to reveal detailed instructions Specifiers: Click on the icon in the WD toolbar to reveal detailed instructions (Specifier Note: The purpose of this guide specification is to assist the specifier in correctly specifying metal wall panels

More information

(Project Location) (your firm's name)

(Project Location) (your firm's name) SECTION 07 21 00 THERMAL INSULATION PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including the Conditions of the Contract and Division 01 Specification Sections

More information

CENTRIA MetalWrap Insulated-Composite Backup Panel System

CENTRIA MetalWrap Insulated-Composite Backup Panel System CENTRIA MetalWrap Insulated-Composite Backup Panel System CENTRIA MetalWrap Insulated Composite Backup Panel System is designed to be used with CENTRIA metal wall panel cladding to create a complete rainscreen

More information

TerraClad TM General Specifications

TerraClad TM General Specifications TerraClad TM General Specifications PRODUCT NAMES: Terra cotta Panels and Related Work MANUFACTURER: Boston Valley Terra Cotta 6860 S. Abbott Road Orchard Park, NY 14127 Phone: 888-214-3655 Phone: 716-649-7490

More information

SECTION STILE AND RAIL WOOD DOORS

SECTION STILE AND RAIL WOOD DOORS SECTION 08 1433 NOTE: THIS SECTION USES THE TERM "ARCHITECT." CHANGE THIS TERM TO IDENTIFY THE DESIGN PROFESSIONAL AS DEFINED IN THE AGREEMENT OR GENERAL CONDITIONS OF THE CONTRACT. PART 1 GENERAL 1.01

More information

SECTION METAL BUILDING SYSTEMS

SECTION METAL BUILDING SYSTEMS SECTION 13 3419 PART 1 GENERAL 1.01 SECTION INCLUDES A. Manufacturer-engineered, shop-fabricated structural steel building frame. B. Insulated Metal wall and roof panels including gutters and downspouts.

More information

PRESTON HEALTH SERVICES ARCHITECT'S NO. 2700

PRESTON HEALTH SERVICES ARCHITECT'S NO. 2700 SECTION 09 5113 - ACOUSTICAL PANEL CEILINGS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 08 - OPENINGS. A. This Section includes fixed and operable aluminum-framed windows.

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 08 - OPENINGS. A. This Section includes fixed and operable aluminum-framed windows. SECTION 085113 - ALUMINUM WINDOWS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes fixed and operable aluminum-framed windows. 1.2 PERFORMANCE REQUIREMENTS A. General: Provide aluminum windows capable

More information

CENTRIA FORMABOND. Aluminum Composite Wall System

CENTRIA FORMABOND. Aluminum Composite Wall System CENTRIA FORMABOND Aluminum Composite Wall System CENTRIA FormaBond is the only true aluminum composite panel wall system designed, manufactured and fabricated by a single, reliable national manufacturer

More information

Product Guide Specification

Product Guide Specification April 2014 6840 SW 81 Terrace Miami, Florida 33143 Phone 305-666-6676 Fax 305-666-7675 Website www.trimstonepanels.com E-mail stoneworks@stoneworksofart.com Product Guide Specification Specifier Notes:

More information

SECTION THERMOPLASTIC POLYOLEFIN (TPO) ROOFING PART 1 - GENERAL 1.1 RELATED DOCUMENTS

SECTION THERMOPLASTIC POLYOLEFIN (TPO) ROOFING PART 1 - GENERAL 1.1 RELATED DOCUMENTS SECTION 075423 - THERMOPLASTIC POLYOLEFIN (TPO) ROOFING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including Division 00 Bidding Requirements and other Division

More information

SECTION COLD-FORMED METAL FRAMING

SECTION COLD-FORMED METAL FRAMING SECTION 05400 PART I - GENERAL 1.01 DESCRIPTION A. Scope: Work of this Section shall include all materials and installation necessary to provide all cold formed metal framing. B. This Section includes:

More information

SECTION ROOF SPECIALTIES

SECTION ROOF SPECIALTIES PART 1 - GENERAL 1.1 DESCRIPTION SECTION 07 71 00 1. Use this section only for NCA projects. 2. Delete between // // if not applicable to project. Also delete any other item or paragraph not applicable

More information

EDGEWATER, FLORIDA JUNE 14, 2010

EDGEWATER, FLORIDA JUNE 14, 2010 SECTION 09 2400 - PORTLAND CEMENT PLASTER PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification

More information

SECTION METAL COMPOSITE MATERIAL WALL PANELS

SECTION METAL COMPOSITE MATERIAL WALL PANELS SECTION 07 4264 METAL COMPOSITE MATERIAL WALL PANELS USE THIS SECTION WHEN SPECIFYING C.R. LAURENCE EWS SERIES 100 STANDARD WET SEAL FOR ALUMINUM-FACED, STAINLESS STEEL, COPPER, OR TITANIUM COMPOSITE MATERIAL

More information

Repair Maintenance Hangar Phase II August 2010

Repair Maintenance Hangar Phase II August 2010 SECTION 08800 GLASS AND GLAZING PART 1 - GENERAL 1.01 SUMMARY A. Section Includes: 1. Monolithic glass. 2. Insulating glass. 3. Mirror glass. 4. Glazing accessories. B. Types of work in this section include

More information

Specifications. When specifying metal panel roof systems, roof. system designers and specifiers need to be aware

Specifications. When specifying metal panel roof systems, roof. system designers and specifiers need to be aware 32 www.professionalroofing.net OCTOBER 2012 When specifying metal panel roof systems, roof system designers and specifiers need to be aware of specific standards. Sometimes, the standards applicable to

More information

CONTRACT NUMBER: W912DQ-08-C % CORRECTED DESIGN 28 JULY 2008

CONTRACT NUMBER: W912DQ-08-C % CORRECTED DESIGN 28 JULY 2008 SECTION 085413 - FIBERGLASS WINDOWS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

SECTION METAL FLOOR PLATE STAIRS

SECTION METAL FLOOR PLATE STAIRS SECTION 05513 - METAL FLOOR PLATE STAIRS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

DIVISION 10 SPECIALTIES SECTION OPERABLE PARTITIONS

DIVISION 10 SPECIALTIES SECTION OPERABLE PARTITIONS DIVISION 10 SPECIALTIES SECTION 10 22 26 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

A. Submit the following in addition to the standard requirements.

A. Submit the following in addition to the standard requirements. SECTION [13120] OMNIFLEX 300 MODULAR WALL SYSTEM SECTION 1 GENERAL 1.01 SECTION INCLUDES A. This Section specifies all requirements necessary to furnish and install a complete modular wall system including,

More information

SECTION PRE-ENGINEERED BUILDING INSULATION

SECTION PRE-ENGINEERED BUILDING INSULATION PART 1 GENERAL SECTION 07213 PRE-ENGINEERED BUILDING INSULATION Microsoft Word Instructions: Display hidden notes to specifier by using "Tools"/"Options"/"View"/"Hidden Text". 1.1 SECTION INCLUDES A. Pre-Engineered

More information

SECTION RADIATION SHIELDING ENCLOSURE Low Intensity Radiation Protection

SECTION RADIATION SHIELDING ENCLOSURE Low Intensity Radiation Protection SECTION 13090 RADIATION SHIELDING ENCLOSURE Low Intensity Radiation Protection Prepared by: 90 Dayton Avenue, Unit 4B, Suite 13 Passaic, NJ 07055 (973) 574-9077 13090-1 LOW INTENSITY RADIATION PROTECTION

More information

Specifiers: Click on the icon in the WORD toolbar to reveal detailed instructions

Specifiers: Click on the icon in the WORD toolbar to reveal detailed instructions Specifiers: Click on the icon in the WORD toolbar to reveal detailed instructions SECTION 07 42 13 METAL WALL PANELS Kingspan Insulated Panels KS Series Insulated Wall Panel System PART 1 - GENERAL 1.1

More information

SECTION MANUFACTURED ROOF AND WALL PANELS SECTION SHEET METAL ROOFING

SECTION MANUFACTURED ROOF AND WALL PANELS SECTION SHEET METAL ROOFING SPECIFICATIONS www.englertinc.com MANUFACTURER ENGLERT, INC. 1200 Amboy Avenue Perth Amboy, New Jersey 08861 Tel: (732) 826-8614 Fax: (732) 826-8865 PART I GENERAL 1.01 WORK INCLUDED SECTION 07410 - MANUFACTURED

More information

A. Access doors and frames are part of an access door and frame allowance.

A. Access doors and frames are part of an access door and frame allowance. SECTION 08 31 13 ACCESS DOORS AND FRAMES PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

CENTRIA EcoScreen Perforated Screen Wall Panels

CENTRIA EcoScreen Perforated Screen Wall Panels CENTRIA EcoScreen Perforated Screen Wall Panels CENTRIA EcoScreen Perforated Screen Wall Panels offer a variety of aesthetic solutions to equipment and other screening design requirements. EcoScreen Panels

More information

SECTION MANUFACTURED ROOF AND PANELS SECTION SHEET METAL ROOFING

SECTION MANUFACTURED ROOF AND PANELS SECTION SHEET METAL ROOFING SPECIFICATIONS www.englertinc.com MANUFACTURER ENGLERT, INC. 1200 Amboy Avenue Perth Amboy, New Jersey 08861 Tel: (732) 826-8614 Fax: (732) 826-8865 PART I - GENERAL 1.01 WORK INCLUDED SECTION 07410 -

More information

SECTION INSULATED CORE METAL WALL PANELS 09/09

SECTION INSULATED CORE METAL WALL PANELS 09/09 SECTION 07 42 16 INSULATED CORE METAL WALL PANELS 09/09 PART 1 GENERAL 1.1 SYSTEM DESCRIPTION 1.1.1 Insulated Core Metal Wall Panel System Factory-foamed horizontal and vertical wall panel system consisting

More information

GUIDE SPECIFICATION: DUCT LINER

GUIDE SPECIFICATION: DUCT LINER GUIDE SPECIFICATION: DUCT LINER This specification guide includes thermal & acoustical insulation for ductwork and air handling systems. This section is based on the format recommended by MICA (Midwest

More information

Aluminum Flush Doors and Frames SPECIFICATIONS. Section [8120] PART 1 GENERAL

Aluminum Flush Doors and Frames SPECIFICATIONS. Section [8120] PART 1 GENERAL Aluminum Flush Doors and Frames SPECIFICATIONS Section 081116 [8120] Cline Aluminum Doors, Inc. 112 32nd Avenue West Bradenton, FL 34205-8907 Toll-Free (800) 648-6736 Office (941) 746-4104 Fax (941) 746-5153

More information

INSULATED PANEL OVERVIEW

INSULATED PANEL OVERVIEW INSULATED PANEL OVERVIEW Our various series of wall and roof panels are filled with non CFC polyisocyanurate foam. The panels are manufactured in a uniform pressure laminating process that bonds metal

More information

Specification for larson by Alucoil PE Core Aluminum Composite Material (ACM)

Specification for larson by Alucoil PE Core Aluminum Composite Material (ACM) Specification for larson by Alucoil PE Core Aluminum Composite Material (ACM) PART 1: GENERAL 1.01 SCOPE A. SECTION INCLUDES 1. The extent of panel system work is indicated on the drawings and in these

More information