1 SECTION INSULATED METAL WALL PANELS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this Section. 1.2 SUMMARY A. Section Includes: 1. Foamed-insulation-core metal wall panels. 2. Laminated-fire-resistant metal wall panels. 3. Laminated-insulation-core metal wall panels. 1.3 PREINSTALLATION MEETINGS A. Pre-bid Conference: Conduct conference at Kodiak AST Post & Kodiak 2921 # A Mill Bay Road, Kodiak Alaska Thursday January 23, 2014 at 1:30 p.m. 1.4 ACTION SUBMITTALS A. Product Data: For each type of product. B. LEED Submittals: 1. EA Energy and Atmosphere a. EA Credit 1: Optimize Energy Performance. 1) Demonstrating percentage of performance improvement that meets or surpasses ASHRAE/IESNA Standard EA Credit 2: Minimum Energy Performance 3. MR Material and Resource a. MR Credit 1.1 & 1.2: Building Reuse 1) Maintain Existing Walls, Floors & Roof 2) Maintain Interior Non-Structural Elements b. MR Credit 3: Materials Reuse c. MR Credit 4: Recycled Content INSULATED METAL WALL PANELS
2 1) Percentage weight of post-consumer and pre-consumer recycled content use materials with recycled content. 2) Recycled content value of product assembly by weight. 3) Indicate total value (cost) of each product used. 4. MR Credit 6: Rapidly Renewable Materials 5. IEQ Indoor Environmental Quality a. IEQ Credit 4.1: Low-Emitting Materials Adhesives and Sealants 1) Product data on adhesives and sealants to comply with standards for South Coast Air Quality Management District rule # ) Product data for paint and coatings having no VOC's 6. ID- Innovation in Design: C. Shop Drawings: a. ID Credits 1.1 to Include elevations, fastening patterns, and sections of each condition. 2. Include material type, metal thickness, paint finish, and manufacturer's installation suggestions. D. Panel Samples: Submit 1 ft - 0 in (30.48 cm) by full width sample panel indicating the metal, texture, and finish proposed. 1.5 INFORMATIONAL SUBMITTALS A. Product test reports. B. Warranties: Samples of special warranties. 1.6 QUALITY ASSURANCE A. Installer Qualifications: Installed by a contractor with a minimum of five (5) years experience with this type of construction, and documentation indicating successful completion of contracts for projects of similar size, scope and materials. B. Manufacturer Qualifications: Manufacturer s production and quality processes are inspected on a quarterly basis by third party quality control auditing programs through Factory Mutual, Underwriter Laboratories, and Intertek Testing Services. Quality control manuals for each accreditation agency are in place detailing the production and quality processes and methods used in the manufacturing of product. 1.7 DELIVERY, STORAGE, AND HANDLING INSULATED METAL WALL PANELS
3 A. Protect products of metal panel system during shipping, handling, and storage to prevent staining, denting, deterioration of components, or other damage. B. Deliver, unload, store, and erect metal panels and accessory items in a manner to prevent bending, warping, twisting, and surface damage. C. Store panels in accordance with manufacturer's written instructions. D. Shield foam-insulated metal wall panels from direct sunlight until installation. E. Store products off the ground, with panels sloped for drainage and covered to protect factory finishes from damage. Stack bundles no more than two high. 1.8 WARRANTY A. Warranty: Manufacturer's written limited warranty providing panels to be free from defects in materials and workmanship, excluding coil coatings (paint finishes) that are covered under separate warranty. 1. Warranty Period: Two years from date of Substantial Completion. B. Warranty on Panel Finishes: Manufacturer's standard form in which manufacturer agrees to repair finish or replace metal panels that show evidence of deterioration of factory-applied finishes within specified warranty period. 1. Finish Warranty Period: a. 40 year limited warranty on the exterior paint finish for adhesion to the metal. substrate b. 30 year limited warranty on the exterior paint finish for chalk and fade. PART 2 - PRODUCTS 2.1 PERFORMANCE REQUIREMENTS A. Recycled Content of Steel Products: Postconsumer recycled content plus one-half of preconsumer recycled content not less than 25 percent. B. Structural Performance: Provide metal panel systems capable of withstanding the effects of the following loads, based on testing according to ASTM E 72: 1. Wind Loads: Verified using a 20 psf simulated wind load. 2. Deflection Limits: For wind loads, no greater than 1/180 for exterior wall panels and 1/120 for partition and liner walls. 3. Large Missile Impact Test: Conducted in accordance with ASTM E 1886 and ASTM E INSULATED METAL WALL PANELS
4 C. Air Infiltration: Air leakage of not more than 0.06 cfm/sq. ft. (0.3 L/s per sq. m). Air infiltration shall not exceed 0.01 cfm/sq. ft (0.05 L/s per sq. m) at 6.24 psf (.30 kpa), and 0.04 cfm/ sq. ft (0.2 L/s per sq. m) of wall area] when tested according to ASTM E 283 at a static pressure of 12 psf (.576 kpa). D. Static Water Penetration: There shall be no uncontrolled water penetration through the panel joints at a static pressure of 20 psf (.96 kpa) when tested in accordance with ASTM E 331. E. Dynamic Water Penetration: There shall be no uncontrolled water penetration through the panel joints when subjected to a 95 mph slip stream air flow and application of water for a 15 minute period in accordance with AAMA F. Condensation Resistance Factor: The minimum condensation resistance factor of the panel shall be 92 when tested in general accordance with AAMA G. Thermal Performance: Panels shall provide a K-factor of 0.14 btu/sf/hr/deg F at a 75 deg F (mean temperature when tested in accordance with ASTM C 518. H. Fire Test Response Characteristics: 1. Surface Burning Characteristics: The insulated core shall have been tested in accordance with ASTM E 84 for surface burning characteristics. The core shall have a maximum flame spread of 25 and a smoke developed rating of Factory Mutual Research Corporation (FMRC) Standard 4880: Panel assembly shall not support a self-propagating fire which reaches any limits of the 50 foot high corner test structure as evidenced by flaming or material damage of the ceiling of the assembly. 3. Fire Propagation: The fire assembly shall meet the requirements of the standard for NFPA 285 and NFPA 286. Heat potential shall be determined using NFPA 259 Test Method for Potential Heat of Building Materials. 4. Canadian Certifications Flame spread: Evaluation of fire spread over the exterior surface shall be conducted and in compliance with CAN/ULC S IBC Chapter 26: Panel performance under the above test methods, shall meet the requirements of IBC, Chapter on foam plastics. 6. Laminated Fire-Resistive Metal Panel, Fire Resistance Data: a. Finished panel in a 4 in thickness shall meet the requirements of a one (1) hour fire resistance rating for non- load bearing wall in accordance with UL 263 (per UL design U050 for US and design W021 for Canada), ASTM E119 and CAN/ULC S101 (per Intertek design MS/WA 60-1). b. 1 and 2 hour fire rated wall panels shall meet the requirements of Fire Door and Window Assemblies as listed by UL in accordance with UL 9, CAN4-S106 and UBC Standard 7-4 ( per UL designs SP and WA ) 2.2 FOAMED-INSULATION-CORE METAL WALL PANELS A. General: Provide factory-formed and -assembled metal wall panels fabricated from two rollformed metal facing sheets chemically bonded to insulation core foamed in place during fabrication, and with joints between panels designed to form weather tight seals. Include accessories required for weather tight installation. INSULATED METAL WALL PANELS
5 1. Panel Performance: Kodiak AWT Hangar, Kodiak Airport Alaska, a. Freeze/Heat Cycling: No delamination, surface blistering, or permanent bowing when subjected to cyclic temperature extremes of -20 deg F to +180 deg F for 21 eight hour cycles. b. Humid Aging: Volume increase not greater than 6.0 percent and no delamination or metal corrosion when tested for seven days at 140 deg F and 100 percent relative humidity according to ASTM D c. Fatigue: No evidence of delamination, core cracking, or permanent bowing when tested to a 20-lbf/sq. ft. positive and negative wind load and with deflection of L/180 for 2 million cycles. d. Autoclave: No delamination when exposed to 2-psi pressure at a temperature of 212 deg F for 2-1/2 hours. 2. Insulation Core: Polyurethane foam using a non-cfc blowing agent, with maximum flame-spread and smoke-developed indexes of 25 and 450, respectively. a. Closed-Cell Content: 92 percent when tested according to ASTM D b. Density: 2.0 to 2.6 lb/cu. ft. when tested according to ASTM D c. Compressive Strength: Minimum 20 psi when tested according to ASTM D d. Shear Strength: 26 psi when tested according to ASTM C 273/C 273M. B. Concealed-Fastener, Foamed-Insulation-Core Metal Wall Panels CF42: Formed with tongueand-groove panel edges; designed for sequential installation by interlocking panel edges and mechanically attaching panels to supports using concealed clips or fasteners. 1. Basis-of-Design Product: Subject to compliance with requirements, provide Metl-Span LLC product named or comparable product by one of the following: a. CENTRIA Architectural Systems. b. Firestone Building Products. c. King Span LLC 2. Profiled Wall Panels: Metl-Span CF concealed fastener wall panel: a. CF-42 Wall Panel, 42 in module width, with Mesa profiled face with a Light Mesa profiled liner. 1) Thickness: 4 in. 3. Thermal-Resistance Value (R-Value): R-32 according to ASTM C Materials: a. Exterior Face: G-90 galvanized steel conforming to ASTM A 653 and/or prefinished AZ50 aluminum-zinc coated steel conforming to ASTM A 792, minimum grade 33 with stucco embossed texture. 1) Thickness: 24 Ga. INSULATED METAL WALL PANELS
6 b. Interior Liner: G-90 galvanized steel conforming to ASTM A 653 and/or AZ50 aluminum-zinc coated steel conforming to ASTM A 792, minimum grade 33, with stucco embossed texture. 1) Thickness: 26 Ga. c. Foam Core: Continuously foamed-in-place, zero ODP and zero VOC closed cell polyurethane. d. Flashing and Trim: 5. Finishes: 1) Provide complete insulated metal wall panel assembly incorporating trim and miscellaneous flashings. Provide required fasteners, clips, closures, tapes, and sealants. 2) Flashing and trim shall be brake-formed sheet metal in the same thickness and finish to match panels. a. Exterior face sheet: 1) Base Primer: Nominal 0.2 mil. 2) Finish Coat: Nominal 0.7 mil full strength 70 percent PVDF Fluoropolymer coating in manufacturer's standard colors. b. Interior Sheet: 6. Side Connections: 1) Primer: Nominal 0.2 mil primer. 2) Finish Coat: Nominal 0.7 mil polyester coating in USDA compliant Igloo White. a. CF-42 wall panel shall have offset double tongue and groove joinery with an extended metal shelf allowing fasteners to penetrate both metal faces with clips concealed in the side joint. 7. Sealants: a. All sealants shall be field applied to ensure vapor and water tightness. 2.3 FABRICATION A. General: Fabricate and finish metal panels and accessories at the factory, by manufacturer's standard procedures and processes, as necessary to fulfill indicated performance requirements demonstrated by laboratory testing. Comply with indicated profiles and with dimensional and structural requirements. B. Provide panel profile, including major ribs and intermediate stiffening ribs, if any, for full length of panel. INSULATED METAL WALL PANELS
7 C. Fabricate metal panel joints with factory-installed captive gaskets or separator strips that provide a weather tight seal and prevent metal-to-metal contact, and that minimize noise from movements. D. Sheet Metal Flashing and Trim: Fabricate flashing and trim to comply with manufacturer's recommendations and recommendations in SMACNA's "Architectural Sheet Metal Manual" that apply to design, dimensions, metal, and other characteristics of item indicated. 2.4 FINISHES A. Panels and Accessories: 1. Two-Coat Fluoropolymer: Fluoropolymer finish containing not less than 70 percent PVDF resin by weight in color coat. Prepare, pretreat, and apply coating to exposed metal surfaces to comply with coating and resin manufacturers' written instructions. PART 3 - EXECUTION 3.1 EXAMINATION A. Examine all structural steel before beginning installation to insure that all supporting members are straight, level, plumb and satisfactory for panel installation. B. Intermediate framing member (secondary structural supports) alignment tolerances required, as specified below: 1. 0 to ¼ inch outward of the actual wall framing plane for members at 10 ft or greater spacing. C. Do not begin installation until unsatisfactory conditions are corrected. D. Beginning of installation shall signify the structure and adjacent conditions as being proper and acceptable. 3.2 PREPARATION A. Miscellaneous Supports: Install sub-framing, furring, and other miscellaneous panel support members and anchorages according to ASTM C 754 and metal panel manufacturer's written recommendations. 3.3 INSULATED METAL WALL PANEL INSTALLATION A. General: Apply continuous ribbon of sealant to panel joint on concealed side of insulated metal wall panels as vapor seal; apply sealant to panel joint on exposed side of panels for weather seal. INSULATED METAL WALL PANELS
8 1. Fasten foamed-insulation-core metal wall panels to supports with fasteners at each lapped joint at location and spacing and with fasteners recommended by manufacturer. 2. Apply panels and associated items true to line for neat and weather tight enclosure. Avoid "panel creep" or application not true to line. 3. Provide metal-backed washers under heads of exposed fasteners on weather side of insulated metal wall panels. 4. Locate and space exposed fasteners in uniform vertical and horizontal alignment. Use proper tools to obtain controlled uniform compression for positive seal without rupture of washer. 5. Provide sealant tape at lapped joints of insulated metal wall panels and between panels and protruding equipment, vents, and accessories. 6. Apply a continuous ribbon of sealant tape to panel side laps and elsewhere as needed to make panels weather tight. 7. Apply snap-on battens to exposed-fastener, insulated-core metal wall panel seams to conceal fasteners. B. Foamed-Insulation-Core Metal Wall Panels: Fasten metal wall panels to supports with concealed clips at each joint at location and spacing and with fasteners recommended by manufacturer. Fully engage tongue and groove of adjacent panels. 1. Install clips to supports with self-tapping fasteners. C. Accessory Installation: Install accessories with positive anchorage to building and weather tight mounting, and provide for thermal expansion. Coordinate installation with flashings and other components. D. Flashing and Trim: Comply with performance requirements, manufacturer's written installation instructions, and SMACNA's "Architectural Sheet Metal Manual." Provide concealed fasteners where possible, and set units true to line and level. Install work with laps, joints, and seams that are permanently watertight. 3.4 FIELD QUALITY CONTROL A. Panel installer shall inspect and approve each completed wall area and shall be responsible for protection of completed work from damage by other trades. 3.5 CLEANING A. Remove temporary protective coverings and strippable films before exposure to sunlight. B. Wipe finished surfaces clean of any filings caused by drilling or cutting to prevent rust staining. C. Replace metal panels that have been damaged or have deteriorated beyond successful repair by finish touchup or similar minor repair procedures. END OF SECTION INSULATED METAL WALL PANELS
Guide Specifications. Metl-Span 7.2 Insul-Rib Wall Panel For Commercial & Industrial Buildings PART 1 GENERAL Master Format Section
Guide Specifications 2012 Master Format Section 07 42 13.19 Metl-Span 7.2 Insul-Rib Wall Panel For Commercial & Industrial Buildings PART 1 GENERAL 1.1 Work Included A. Pre-insulated metal panel cladding
More informationGuide Specifications. Metl-Span Architectural Insulated Metal Panel For Commercial & Industrial Buildings PART 1 GENERAL
Guide Specifications 2012 Master Format Section 07 42 13.19 Metl-Span Architectural Insulated Metal Panel For Commercial & Industrial Buildings PART 1 GENERAL 1.1 Work Included A. Pre-insulated metal panel
More informationUnion County Vocational - Technical Schools Scotch Plains, New Jersey
SECTION 074213 - INSULATED METAL WALL PANELS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More informationA. Pre-Installation Conference: Conduct conference at [project site] <insert location>.
SECTION 074213.23 METAL COMPOSITE MATERIAL WALL PANELS PART 1 GENERAL 1.1 SUMMARY A. Exterior cladding consisting of formed metal composite material (MCM) sheet, secondary supports and anchors to structure,
More informationDIVISION 7: MOISTURE PROTECTION SECTION 07417: INSULATED METAL PANELS
DIVISION 7: MOISTURE PROTECTION SECTION 07417: INSULATED METAL PANELS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions
More informationA. Pre-Installation Conference: Conduct conference at [project site] <insert location>.
SECTION 074213.23 METAL COMPOSITE MATERIAL WALL PANELS PART 1 GENERAL 1.1 SUMMARY A. Exterior cladding consisting of formed metal composite material (MCM) sheet, secondary supports and anchors to structure,
More informationArchitectural Wall Products Guide Specifications
Western States Metal Roofing 901 W. Watkins St. Phoenix, AZ 85007 PH: 602-495-0048 FX: 602-261-7726 Architectural Wall Products Guide Specifications FORMED METAL WALL PANELS This Guide Specification is
More informationAlply CLASSIC WALL Architectural Insulated Panel Wall System
SECTION 07 42 13 INSULATED METAL WALL PANELS ALPLY Insulated Panels Alply CLASSIC WALL Architectural Insulated Panel Wall System PART 1 / GENERAL 1.1 SYSTEM DESCRIPTION A. Smooth, non-embossed steel, insulated
More informationArchitectural Roof Products Guide Specifications
Western States Metal Roofing 901 W. Watkins St. Phoenix, AZ 85007 PH: 602-495-0048 FX: 602-261-7726 Architectural Roof Products Guide Specifications FORMED METAL ROOF AND WALL PANELS This Guide Specification
More informationSECTION COMPOSITE WALL PANELS PART 1 GENERAL 1.01 SECTION INCLUDES
SECTION 07 4243 - PART 1 GENERAL 1.01 SECTION INCLUDES A. Composite wall panel system consisting of aluminum-faced composite panels in a rainscreen application as part of the assembly described below.
More informationArchitectural Roof and Wall Products Guide Specifications
Architectural Roof and Wall Products Guide Specifications Western States Metal Roofing 901 W. Watkins St. Phoenix, AZ 85007 PH: 602-495-0048 FX: 602-261-7726 FORMED METAL WALL PANELS This Guide Specification
More informationArchitectural Roof Products Guide Specifications
Western States Metal Roofing 901 W. Watkins St. Phoenix, AZ 85007 PH: 602-495-0048 FX: 602-261-7726 Architectural Roof Products Guide Specifications FORMED METAL ROOF AND WALL PANELS This Guide Specification
More informationPART 1 / GENERAL SECTION ALUMINUM PLATE PANEL SYSTEM. ALPLY Insulated Panels. Alply TECH WALL Aluminum Plate System 2002
SECTION 07 42 13 ALUMINUM PLATE PANEL SYSTEM ALPLY Insulated Panels Alply TECH WALL Aluminum Plate System 2002 PART 1 / GENERAL 1.1 SYSTEM DESCRIPTION A. Preformed Aluminum Plate System for Screen wall
More informationArchitectural Roof and Wall Products Guide Specifications
Architectural Roof and Wall Products Guide Specifications 901 W. Watkins St. Phoenix, AZ 85007 PH: 602-495-0048 FX: 602-261-7726 FORMED METAL ROOF AND WALL PANELS This Guide Specification is to be used
More informationGuide Specifications ADP Series SECTION SHEET METAL ROOFING
PART 1 GENERAL 1.01 SUMMARY A. Section Includes: Sheet metal roofing panels, metal trim, accessories, fasteners, closures, and sealants. [Specifier Note: Edit paragraph below to suit project requirements.]
More informationSECTION COMPOSITE METAL WALL PANEL SYSTEM (Accu-Trac Low Profile DS)
SECTION 07412 COMPOSITE METAL WALL PANEL SYSTEM (Accu-Trac Low Profile DS) PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions
More informationNorth Hanover Township School District North Hanover Township, New Jersey
SECTION 084413 - GLAZED ALUMINUM CURTAIN WALLS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01
More informationIce Rink Renovation & New Clubhouse
SECTION 074243- METAL COMPOSITE MATERIAL WALL PANELS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division
More informationArchitectural Roof and Wall Products Guide Specifications
Architectural Roof and Wall Products Guide Specifications 901 W. Watkins St. Phoenix, AZ 85007 PH: 602-495-0048 FX: 602-261-7726 FORMED METAL ROOF AND WALL PANELS This Guide Specification is to be used
More informationStudent Services & Classroom Addition
SECTION 074243 - METAL COMPOSITE MATERIAL WALL PANELS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division
More informationCOLLEGE OF STATEN ISLAND
SECTION 07415 ALUMINUM PLATE CEILING PANELS PART 1 GENERAL 1.01 SUMMARY A. Section Includes 1. The extent of panel system work is indicated on the drawings and in these specifications. The following specification
More informationGENERAL SPECIFICATION FOR FIRE RATED APPLICATIONS
I N SULROCK FIRE RATED METAL PANELS GENERAL SPECIFICATION FOR FIRE RATED APPLICATIONS 1. GENERAL 1.1. Summary Fire-rated panels as shown on the drawings shall be INSULROCK brand panels as supplied by Green
More informationMETL-SPAN HPCI Barrier Insulated Metal Wall Panels
METL-SPAN HPCI Barrier Insulated Metal Wall Panels Metl-Span Insulated Metal Panels (IMPs) consist of two single-skin metal facings and a factory-foamedin-place core. Metl-Span offers IMPs for both roof
More informationNRM-7000 Guide Specifications
NRM-7000 Guide Specifications MANUFACTURER www.nuraymetals.com sales@nuraymetals.com 800-700-7228 SECTION 07 411 PREFORMED ROOF & WALL PANELS PART 1 - GENERAL 1.1 SUMMARY A. Section includes complete system
More informationSECTION STAINLESS STEEL WALL PANELS
SECTION 07400 PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Dry joint, Rainscreen stainless steel wall panel system. 2. Accessories including attachments, clips, sub girts, shims, and fasteners 3.
More informationMagnolia Transit Center Expansion SECTION METAL SOFFIT PANELS
Magnolia Transit Center Expansion 07416-1 SECTION 07416 METAL SOFFIT PANELS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary
More informationPROJECT LOCATION SECTION COPPER METAL PLATE WALL PANELS
SECTION 07 4213.25 PART 1- GENERAL 1.01 SECTION INCLUDES A. Copper metal plate wall panels. 1.02 RELATED REQUIREMENTS A. Section 05 4000 Cold-Formed Metal Framing: Wall panel substrates support framing.
More informationSL150 Guide Specification
SL150 Guide Specification This is a suggested guide specification for metal roofing projects where the SL150 panel system is applicable. Questions regarding applicability should be discussed with Union
More informationSPECIFICATIONS FOR. CEI Composite Materials, LLC Featuring R4000 Rear Back Ventilated Rainscreen System. Section Aluminum Composite Panels
SPECIFICATIONS FOR (1/13 Edition) CEI Composite Materials, LLC Featuring R4000 Rear Back Ventilated Rainscreen System Section 074243 Aluminum Composite Panels (Based upon CEI Composite Materials R4000
More informationSECTION METAL ROOF AND SOFFIT PANELS
Metal Panel Systems, Inc. 11506 Reading Road Cincinnati, Ohio 45241-2512 Telephone: 800-554-6126 or 513-554-6120 Fax: 513-554-6121 www.metalpanelsystems.com info@metalpanelsystems.com Specifications for
More informationA. Omega-Lite aluminum-faced composite panels, air and vapor barrier, attachments and sealants.
Section 07 42 13 Page 1 PART 1 GENERAL 1.1 SECTION INCLUDES A. Omega-Lite aluminum-faced composite panels, air and vapor barrier, attachments and sealants. 1.2 RELATED SECTIONS A. Section 06112 - Framing
More informationSECTION SLOPED TRANSLUCENT METAL SKYLIGHT SYSTEM
PART 1- GENERAL 1.1 SUMMARY A. Section Includes: SECTION 084523 - SLOPED TRANSLUCENT METAL SKYLIGHT SYSTEM 1. Flat factory prefabricated structural insulated translucent sandwich panels; with glazed endwalls.
More informationSPECIFICATIONS FOR AluSystems Aluminum Composite Panels Series 20 Dry Joint 1.00 GENERAL 1.01 RANGE OF WORK Section includes: Laminated panels and attachment systems for use as exterior cladding. A. Provide
More informationSECTION STANDING SEAM METAL ROOFING
PART 1 - GENERAL 1.1 DESCRIPTION SECTION 07 41 13 SPEC WRITER NOTES: 1. Use this section only for NCA projects. 2. Use for roofing sloped 1 in 4 (3 in/ft) or greater. 3. Delete between // // if not applicable
More informationCS-100 Guide Specifications
MANUFACTURER CUSTOM-BILT METALS 1333 Corporate Drive, Suite 103 Irving, Texas 75038-2520 (800) 826-7813 or info@custombiltmetals.com www.custombiltmetals.com CS-100 Guide Specifications This Guide Specification
More information1. Include similar Samples of trim and accessories involving color selection.
SECTION 074116- INSULATED METAL ROOF PANELS PART 1 - GENERAL 1.1 RELATED DOCUMENTS Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More informationEMBRY RIDDLE PRESCOTT SECTION METAL COMPOSITE MATERIAL WALL PANELS
SECTION 074213.23 - WALL PANELS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,
More informationC. All anchors, brackets, and hardware attachments necessary to complete the specified structural assembly, when included within project scope.
SECTION 08 4519 - POLYCARBONATE WALL SYSTEM PART 1 GENERAL 1.1 SECTION INCLUDES A. Exterior System: The design, manufacture and installation of an aluminum and polycarbonate insulating translucent system.
More informationSECTION METAL ROOF PANELS. A. Vertical-rib, seamed joint, standing seam metal roof panels, with related metal trim and accessories.
SECTION 07 41 13 - PART 1 - GENERAL 1.1 SECTION INCLUDES A. Vertical-rib, seamed joint, standing seam metal roof panels, with related metal trim and accessories. 1.2 RELATED REQUIREMENTS Specifier: If
More informationOSU PROJECT NO PAGE 1 02 NOV 2006 SECTION METAL ROOF PANELS
OSU PROJECT NO. 30-04-15 PAGE 1 PART 1 GENERAL 1.1 SECTION INCLUDES A. Structural roofing system of preformed steel panels. B. Fastening system. C. Factory finishing. D. Accessories and miscellaneous components.
More informationSECTION ALUMINUM COMPOSITE MATERIAL WALL PANELS. A. Section includes aluminum composite material wall panels.
1/11 SECTION 074213.23 - ALUMINUM COMPOSITE MATERIAL WALL PANELS PART 1 - GENERAL 1.1 SUMMARY A. Section includes aluminum composite material wall panels. 1.2 PRE-INSTALLATION MEETINGS A. Pre-installation
More informationGuide Specification SDP 200
PART 1 GENERAL 1.01 SUMMARY A. Section Includes: Sheet metal roofing panels, metal trim, accessories, fasteners, closures, and sealants. [Specifier Note: Edit paragraph below to suit project requirements.]
More informationSpecifiers: Click on the icon in the WORD toolbar to reveal detailed instructions
Specifiers: Click on the icon in the WORD toolbar to reveal detailed instructions SECTION 07 41 00 ROOF PANELS Kingspan Insulated Panels KingZip Pre-Insulated Standing Seam Metal Roof Panels PART 1 - GENERAL
More informationMetl-Span FW-120 Formed Metal Wall Panels
FW-120 Formed Metal Wall Panels The FW-120 panel is a concealed fastener wall and liner panel that provides a flat appearance. FW- 120 is commonly used for architectural, commercial and industrial markets.
More information1.1 SECTION INCLUDES A. Insulated Metal and FRP Wall and Ceiling Panels and Related Accessories.
Permatherm Specification SECTION 07435 (CSI MasterFormat 1995) SECTION 07 42 43 (CSI MasterFormat 2004) SECTION 07 42 13.19 (CSI MasterFormat 2012) INSULATED METAL and FRP WALL PANELS Part 1: General General:
More informationML150 Guide Specification
ML150 Guide Specification This specification is a guide recommendation for many metal roofing projects. It is available for downloading in both Microsoft WORD and.pdf format for your ease of use. Revise
More informationSECTION EXTERIOR SOLID PHENOLIC RAINSCREEN PANELS
SECTION 074233 EXTERIOR SOLID PHENOLIC RAINSCREEN PANELS PART 1 - GENERAL 1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division
More informationSECTION INSULATED METAL ROOF PANELS. ATAS International, Inc. General Specification for Commercial/Industrial and Architectural Applications
SECTION 07 41 13 INSULATED METAL ROOF PANELS ATAS International, Inc. General Specification for Commercial/Industrial and Architectural Applications PART 1 GENERAL 1.1. Summary The contract drawings indicate
More informationSECTION MANUFACTURED ROOF EXPANSION JOINTS
SECTION 07 71 29 - MANUFACTURED ROOF EXPANSION JOINTS PART 1 -GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division
More informationMETAL COMPOSITE MATERIAL WALL PANELS
MasterSpec Full Length 1 of 10 SECTION 074213.23 - METAL COMPOSITE MATERIAL WALL PANELS PART 1 - GENERAL 1.1 SUMMARY A. Section includes metal composite material wall panels. 1.2 PREINSTALLATION MEETINGS
More informationPage 1 of 5
SPECIFICATIONS COMPOSITE MATERIAL PANEL SYSTEM ESTOLGA 1000 DRY SEAL SYSTEM PART 1 GENERAL 1.01 SECTION INCLUDES A. Exterior cladding consisting of formed metal composite material (MCM) sheet, secondary
More informationCorium Brick Rainscreen System Specifications
CORIUM BRICK RAINSCREEN SYSTEM PART 1 - GENERAL 1.1 SUMMARY A. Work Included: The Work of this Section shall include but not be limited to the following: 1. Corium brick plates 2. Galvanized and coated
More informationGuideline Specifications
Page 1 of 7 PART 1 Guideline Specifications Exterior Aluminum/Composite Wall Panels GENERAL ARROWHEAD 508 SYSTEM Pressure Equalized Rainscreen SECTION 07410 1.01 SUMMARY A. Work of this section included
More informationSECTION METAL ROOF PANEL, STANDING SEAM - SRS3
SECTION 07 41 13.03 METAL ROOF PANEL, STANDING SEAM - SRS3 PART 1 GENERAL 1.1 REFERENCES The publications listed below form a part of this specification to the extent referenced. The publications are referred
More informationAll Metals Fabrication AMF FUSION DRILLFREE ALUMINUM COMPOSITE METAL (ACM) WALL PANEL SPECIFICATION
SECTION 07 42 43 All Metals Fabrication AMF FUSION DRILLFREE ALUMINUM COMPOSITE METAL (ACM) WALL PANEL SPECIFICATION SPEC NOTE: Optional text is indicated by square brackets []. Delete unwanted items and
More informationSECTION AWNINGS
SECTION 10 73 13 AWNINGS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes the following: 1. Fixed metal awnings. 1.2 DEFINITIONS A. Awning: An architectural projection that provides weather protection,
More informationSSL-175. Specifications
SSL-175 Specifications Everlast Metals 10 Enterprise Court Lebanon, PA 17042 Phone: (717) 270-6554 Fax: (717) 270-6569 www.everlastmetals.com 7410 Preformed Metal Roofing PART 1: GENERAL 1.01 SECTION INCLUDES
More informationMetl-Span ThermalSafe Insulated Metal Wall and Ceiling Panels
Insulated Metal Wall and Ceiling Panels Metl-Span's ThermalSafe insulated metal wall and ceiling panels (IMP) are developed to protects against fire penetration. Unlike traditional wall materials, this
More informationUnion County Vocational - Technical Schools Scotch Plains, New Jersey
SECTION 102239 - FOLDING PANEL PARTITIONS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More informationSECTION METAL FRAMED SKYLIGHT. A. Engineering, preparation of fabrication drawings and structural calculations for the entire skylight system.
SECTION 08625 METAL FRAMED SKYLIGHT PART 1 GENERAL 1.01 SECTION INCLUDES: A. Engineering, preparation of fabrication drawings and structural calculations for the entire skylight system. B. Fabrication
More informationSECTION INSULATED METAL WALL PANELS. ATAS International, Inc. General Specification for Commercial/Industrial and Architectural Applications
SECTION 07 42 13 INSULATED METAL WALL PANELS ATAS International, Inc. General Specification for Commercial/Industrial and Architectural Applications PART 1 GENERAL 1.1. Summary The contract drawings indicate
More informationSpecifications for FL-100 Soffit Panel
Union Corrugating Company Specifications for FL-100 Soffit Panel SECTION 07410 METAL SOFFIT PANELS PART 1 GENERAL 1.1 DESCRIPTON A. Section Includes: 1. Preformed metal soffit panel system 2. Associated
More informationST. JOHNS COUNTY ARCH. PROJ. NO SECTION PREFABRICATED ALUMINUM CANOPIES PART 1 - GENERAL 1.1 RELATED DOCUMENTS
SECTION 10530 PREFABRICATED ALUMINUM CANOPIES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification
More informationDIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ROOFING AND SIDING PANELS REPORT HOLDER: KINGSPAN INSULATED PANELS, INC.
0 Most Widely Accepted and Trusted ICC-ES Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-1143 Reissued 04/2017 This report is subject to renewal 04/2018. DIVISION: 07 00 00 THERMAL
More informationSECTION EXTERIOR GRILLS AND SCREENS
SECTION 10 82 13 PART 1 GENERAL PART 1 1 SUMMARY A. Section Includes: 1. Exterior perforated aluminum screen wall system with Ombrae TM Optical Tile imaging technology. 2. Accessories including attachments,
More informationSECTION METAL COMPOSITE MATERIAL WALL PANELS
SECTION 074213.23 - METAL COMPOSITE MATERIAL WALL PANELS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division
More informationMetl-Span ShadowRib Formed Metal Wall Panels
ShadowRib Formed Metal Wall Panels ShadowRib is a 3-inch- deep panel that combines aesthetics, economy and function to bring definition to metal structures. ShadowRib is a proven performer and a versatile
More informationDL-200. Specifications
DL-200 Specifications Everlast Metals 10 Enterprise Court Lebanon, PA 17042 Phone: (717) 270-6554 Fax: (717) 270-6569 www.everlastmetals.com 7410 Structural Preformed Metal Roofing PART 1: GENERAL 1.01
More informationSECTION INSULATED CORE METAL WALL PANELS AMERICAN ARCHITECTURAL MANUFACTURERS ASSOCIATION (AAMA)
SECTION 07 42 16.05 INSULATED CORE METAL WALL PANELS PART 1 GENERAL 1.1 REFERENCES AMERICAN ARCHITECTURAL MANUFACTURERS ASSOCIATION (AAMA) AAMA 501.2 AAMA 621 AAMA 2605 (2003) Quality Assurance and Diagnostic
More informationSECTION METAL ROOF PANELS
SECTION 07 41 13 PART 1 GENERAL 1.1 SECTION INCLUDES A. Standing-seam roof panels. B. Metal roofing accessories. 1.2 RELATED SECTIONS A. Section 07 62 00 - Sheet Metal Flashing. B. Section 07 72 00 - Roof
More informationSECTION METAL WALL PANELS
Unience USA, Inc. 2115 Linwood Avenue, Suite 500 Fort Lee, NJ 07024 Phone: 201-676-2467 Fax: 201-944-3660 Email: alfrex@alfrexusa.com Web: www.alfrexusa.com SECTION 07 42 13 METAL WALL PANELS PART 1 GENERAL
More informationSECTION PREFORMED CLADDING. A. Part A and DIVISION 1 of PART B are hereby made a part of this SECTION.
SECTION 074213 PART 1 GENERAL 1.01 GENERAL REQUIREMENTS A. Part A and DIVISION 1 of PART B are hereby made a part of this SECTION. B. Examine all conditions as they exist at the project prior to submitting
More informationCR# August 20, 2015
SECTION 07 40 00 - METAL ROOF AND WALL PANELS PART 1 - GENERAL 1.1 SUMMARY A. Section includes: 1. Factory-formed and field-assembled, standing-seam metal roof panels. 2. Factory-formed and field-assembled,
More informationMETL-SPAN Insulated Concealed Fastener (CF) Metal Wall Panels
Page 1 of 24 METL-SPAN Insulated Concealed Fastener (CF) Metal Wall Panels Metl-Span Insulated Metal Panels (IMPs) consist of two single-skin metal facings and a factory-foamedin-place core. Metl-Span
More informationSECTION ALUMINUM WINDOWS
SECTION 08520 ALUMINUM WINDOWS 1. PART 1 GENERAL 1.1 WORK INCLUDED: 1. Provide labor, material, equipment and services to furnish and install aluminum windows shown on drawings and specified herein. Window
More informationUnion County Vocational - Technical Schools Scotch Plains, New Jersey
SECTION 077200 - ROOF ACCESSORIES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification
More informationArchitectural Roof & Wall Products Guide Specifications MANUFACTURER KLOECKNER METALS KALAELOA BLVD, KAPOLEI, HI 96707,
Architectural Roof & Wall Products Guide Specifications MANUFACTURER KLOECKNER METALS 91-104 KALAELOA BLVD, KAPOLEI, HI 96707, 808-682-3000 This Guide Specification is to be used to develop an office master
More informationSECTION FOLDING ALUMINUM FRAMED WALL SYSTEM
SECTION 08417 FOLDING ALUMINUM FRAMED WALL SYSTEM PART 1 GENERAL 1.1 SUMMARY A. Section includes: 1. Folding aluminum framed door system. 2. Door hardware. 3. Glass. 1.2 SYSTEM DESCRIPTION A. Aluminum-framed
More informationby Rollfab Metal Products
by Rollfab Metal Products SECTION 07460 ALUMINUM SIDING AND SOFFITS PART 1 GENERAL 1.2 RELATED SECTIONS 1.3 REFERENCES A. SECTION INCLUDES B. Aluminum Siding. C. Aluminum Soffits. D. Aluminum trim and
More informationSECTION FIBERGLASS REINFORCED POLYMER (FRP) PANELS
SECTION 07 44 50 FIBERGLASS REINFORCED POLYMER (FRP) PANELS PART 1 - GENERAL 1.1 SECTION INCLUDES A. Design, Engineering, manufacturing and erection of fiberglass reinforced panels. Delegated Design of
More informationMARQUIS Tualatin FIBER-CEMENT SIDING June 15, rev
PART 1 - GENERAL 1.1 SUMMARY A. This Section includes: 1. Reinforced fiber-cement shingle panel siding, 2. Reinforced fiber-cement lap siding. B. Related Sections: 1. Division 1 Section "Quality Requirements"
More informationProject Name Project # Project Information
SECTION 074229.00 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply
More informationLouis Armstrong New Orleans International Airport NOAB Project # North Terminal Development Program Phase 1
Louis Armstrong New Orleans International Airport NOAB Project # 8910-01233 PART 1 - GENERAL SECTION 07 71 29 - MANUFACTURED ROOF EXPANSION JOINTS 1.1 RELATED DOCUMENTS A. Drawings and general provisions
More informationTRUMAN STATE UNIVERSITY GREENWOOD SCHOOL WINDOW REPLACEMENT
SECTION 085200 - WOOD WINDOWS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,
More informationSECTION ROOFING AND SIDING PANELS
PART 1 - GENERAL 1.1 DESCRIPTION SECTION 07 40 00 SPEC WRITER NOTES: 1. Use this section only for NCA projects. 2. Delete between // // if not applicable to project. Also delete any other item or paragraph
More informationTrapezoidal-rib, snap joint, standing seam metal roof panels, with related metal trim and accessories.
SECTION 07 41 13 - PART 1 - GENERAL 1.1 SECTION INCLUDES Trapezoidal-rib, snap joint, standing seam metal roof panels, with related metal trim and accessories. 1.2 RELATED REQUIREMENTS Specifier: If retaining
More informationPROJECT LOCATION SECTION TEXTURED METAL PLATE WALL PANELS
SECTION 07 4213.29 PART 1 - GENERAL 1.01 SECTION INCLUDES A. Textured, aluminum metal plate wall panels. 1.02 RELATED REQUIREMENTS A. Section 05 4000 Cold-Formed Metal Framing: Wall panel substrates support
More informationEC-250 AAMA Pressure-Equalized Aluminum Plate Rainscreen East Coast Metal System
EC-250 AAMA 508-07 Pressure-Equalized Aluminum Plate Rainscreen East Coast Metal System SECTION 074213.16 ALUMINUM PLATE PANELS PART 1 GENERAL 1.1 SECTION INCLUDES A. ALUMINUM PLATE PANELS USED AS EXTERIOR
More informationSECTION ALUMINUM-FRAMED ENTRANCES AND CURTAINWALL
SECTION 084116 - ALUMINUM-FRAMED ENTRANCES AND CURTAINWALL PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Exterior and interior curtainwall framing. 2. Curtainwall framing for punched openings. 3.
More informationDIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL WALL PANELS REPORT HOLDER: METL SPAN, A DIVISION OF NCI GROUP, INC.
0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 2218 Reissued 09/2017 This report is subject to renewal 09/2018. DIVISION: 07 00
More informationSpecifiers: Click on the icon in the WORD toolbar to reveal detailed instructions
Specifiers: Click on the icon in the WORD toolbar to reveal detailed instructions (Specifier Note: The purpose of this guide specification is to assist the specifier in correctly specifying perforated
More informationSECTION C. Water Infiltration: Provide manufactured cupolas and dormers that do not allow water infiltration to cupola and dormer interiors.
PART 1 - GENERAL 1.1 SUMMARY A. Section includes the following: 1. Manufactured exterior cupolas. 2. Manufactured dormers. 3. Historical locomotive weather Vane. 1.2 PERFORMANCE REQUIREMENTS A. General:
More informationSECTION METAL WALL PANELS AMERICAN ARCHITECTURAL MANUFACTURERS ASSOCIATION (AAMA)
SECTION 07 42 13.01 METAL WALL PANELS PART 1 GENERAL 1.1 REFERENCES AMERICAN ARCHITECTURAL MANUFACTURERS ASSOCIATION (AAMA) AAMA 620 AAMA 621 Voluntary Specification for High Performance Organic Coatings
More informationSECTION PORCELAIN TILE WALL SYSTEM. (Porcelanosa Venis Urbatek)
SECTION 074251 (Porcelanosa Venis Urbatek) PART 1 - GENERAL 1.1 GENERAL PROVISIONS A. Attention is directed to the CONTRACT AND GENERAL CONDITIONS and all Sections within DIVISION 01 - GENERAL REQUIREMENTS
More informationJob No Division 07 Section "Sheet Metal Flashing and Trim" for metal flashings installed at perimeters of assemblies.
SECTION 084523 - FIBERGLASS-SANDWICH-PANEL ASSEMBLIES 1.0 PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division
More informationPROJECT LOCATION SECTION ZINC ALLOY METAL PLATE WALL PANELS
SECTION 07 42 13.26 PART 1 - GENERAL 1.01 SECTION INCLUDES A. Zinc alloy metal plate wall panels. 1.02 RELATED REQUIREMENTS A. Section 05 4000 Cold-Formed Metal Framing: Wall panel substrates support framing.
More informationSECTION Structured Polycarbonate Panel Assemblies. Series 3500 BPC System with 40mm Tongue and Groove
Duo-Gard Industries Inc. 40442 Koppernick Road Canton, Michigan 48187 Phone (734) 207-9700 Fax (734) 207-7995 www.duo-gard.com SECTION 08 45 13 Structured Polycarbonate Panel Assemblies Series 3500 BPC
More informationSECTION ALUMINUM WINDOWS
SECTION 08520 ALUMINUM WINDOWS PART 1 - GENERAL 1.01 SUMMARY A. Section includes: 1. Storefront systems and aluminum framed glass doors. 2. Hardware, fasteners, accessories, filler pieces, etc., required
More informationMetl-Span Insulated BattenLok Metal Roof Panels
Metal Roof Panels Insulated BattenLok (IBL) is one of Metl-Span s popular insulated standing seam metal roof panels. The IBL panel is ideal for architectural, commercial, industrial, institutional and
More informationSECTION SHEET MEMBRANE ROOFING
SECTION 07610 SHEET MEMBRANE ROOFING PART I - GENERAL 1.01 DESCRIPTION A. Work of this Section shall include all materials and installation necessary to provide Sheet Metal Roofing as shown and detailed
More information