Wind Impact on Textile Structures
|
|
- Sydney Oliver Simon
- 6 years ago
- Views:
Transcription
1 Wind Impact on Textile Structures J. Wacker TensiNet Symposium, Newcastle, UK, 26 th 28 th of October 2016
2 About Wacker Ingenieure, Wind Engineering Office in Birkenfeld, Germany 3 own wind tunnels Own model fabrication shop Codes for numerical flow simulations 2
3 Typical structures to be investigated with regard to different Wind Engineering Aspects Special constructions = Not covered directly within standards 3
4 Textile Structures = Special Structures Al Bayt Stadium, Al Khor City, Qatar New Stadium in Caracas, Venezuela 4
5 Textile Structures: Wind Engineering Aspects Smoke extraction in case of fire Structural and local wind loads Wind-induced vibrations Snow loads, drift and accumulation Sand loads, drift and accumulation Wind-induced noise Wind-induced rain infiltration Natural Ventilation Wind comfort inside / outside Structural engineer Fire engineer Architect 5
6 Textile Structures: Wind Engineering Aspects Today: Structural and local wind loads Wind-induced vibrations 6
7 Wind Impact on Typical Textile Structures For structural design of textile structures: realistic wind loads are required including dynamic wind loads Examples for shapes not covered in codes Wind tunnel modelling most appropriate method to acquire wind pressure data. 7
8 Wind Tunnel Testing of Textile Structures Due to Great variability and complexity of shapes Geometrically complex eigenmodes, often across-wind vibrations Membrane structures often attached to bigger structures that complicate the wind situation and enhance turbulence and dynamic excitation no proper code approaches available, wind loads extremely case-dependent! Wind tunnel testing of textile structures necessary, realistic evaluation of dynamic responses is complicated 8
9 Wind tunnel testing - Equipment Schematic section of boundary layer wind tunnel Pitot static tube Rigid or aeroelastic building model; scale 1:100 to 1:500) Pressure taps Test building Surroundings Reference pressure (static pressure of the flow) Turn table Simulation of atmospheric boundary layer Floor roughness Approach flow Fence Spires Honeycombs Fans Differential pressure transducers Differential pressure transducer Wind pressure time series c p (t) Voltmeter Filtering + + Verstärker Amplification A D PC Simultaneous measurement of pressure time series Measurement of the reference wind speed 9
10 Wind Loads on Textile Structures: Development of Methodology Formerly: c p = p/ q W = c p,mean * q gust [kn/m 2 ] Wind pressure time series c p (t) Then: W = (c p,mean +/- k * c p,rms ) * q mean [kn/m 2 ] Today: Measurement of c p (t) simultaneously within the area of interest Extraction of critical load pattern with regard to different responses of interest Weighting with influence functions (customized load cases) Calculation of dynamic responses in time domain (several modes) Consideration of added mass and aerodynamic damping effects Typical influence function 10
11 Case study 1: Large textile umbrellas Projects in Medina and Mecca, Saudi Arabia Umbrellas up to 53 m x 53 m Full-scale tests
12 Wind tunnel simulation 12
13 Wind pressure distributions on umbrellas Simultaneous measurements of wind pressure time series cp(t) on upside and downside of umbrella membranes allow evaluation of time-varying pressure field; Time-varying pressure field reveals typical load patterns which are extracted in order to cover typical peak events (load cases) [c p,net ] Blue = upward (1) Red = downward (2) (3) 1) maximum bending moment at base 2) maximum overall suction (upward wind force) 3) maximum overall pressure (downward wind force)
14 Total vertical wind forces on umbrellas Integration of pressure field results in total (global) forces acting on umbrellas; The time-series of vertical force F z shown below exhibits strong upwards and downwards peaks despite low mean forces, there are pronounced events producing high overall suction and high overall pressure; pressure events suction events overall uplift time
15 Wind-induced dynamic response of umbrellas time-varying c p,net -distribution on umbrella and dynamic response (see bottom plot for effective base moment). Effective base moment time 15
16 Conclusion Case Study 1: Large textile umbrellas Simultaneous akquisition of time-dependent wind pressure field is important to be able to consider different load patterns which result in different load cases for one and the same wind direction Consideration of of dynamic wind effects is necessary; consideration in time domain and consideration of several modes yields higher accuracy, corresponding inertia forces cause higher effective loads 16
17 Case Study 2: Huge flat textile roof structure Horizontal flat fabric roof - Operable (retractable) - Size about 180 x 90 m - exposed to strongly turbulent wind (built-up surrounding) 17
18 Wind tunnel tests: Surface pressure distribution Quasi-static time-varying c p,net -distribution obtained from wind-pressure time series (wind tunnel tests) showing both pronounced pressure and suction events: [c p,net ] overall uplift time 18
19 Dynamic Response: Implementation of 12DOF-model Membrane oscillation caused by short-time vertical force pulse in its center shows need of considering more than 1 eigenmode; (animation below based on 12 modes; multimodal representation) Eigenmodes f e,1 =0.32 Hz f e,2 =0.42 Hz f e,3 =0.47 Hz f e,3 =0.49 Hz 19
20 Dynamic Response: Consideration of added mass and aerodynamic damping Movement of membrane up and down caused by wind very light roof with 1st eigemode like horizontal beam Air masses above and beneath moving membrane will be moved, too, and consequently, damping and eigenfrequencies will be changed. 2D-FSI-simulation of middle section was performed for oscillating roof after initial displacement in order to check effective damping and added mass effects. Afterwards the original structural parameters, i.e. structural damping and eigenfrequencies, were adapted carefully. 20
21 Dynamic response caused by wind Wind-induced oscillations (top) and quasistatic and effective vertical force F z (bottom) effective vertical force F z blue = qstat green = effective time 21
22 Final effective load distributions Elaboration of representative load cases for respective target variables c p,net -distribution for load case pressure without dynamic effects (quasi-static wind load): Without dynamics c p,net -distribution for load case pressure including inertial contributions from the moving membrane mass): With dynamics [c p,net ] 22
23 Final effective load distributions Elaboration of representative load cases for respective target variables c p,net -distribution for load case pressure without dynamic effects (quasi-static wind load): Without dynamics c p,net -distribution for load case pressure including inertial contributions from the moving membrane mass): With dynamics [c p,net ] Higher wind loads in central roof part due to pronounced oscillation amplitude in this area (see 1st mode amplitude to the right) 23
24 Conclusion Case Study 2: Huge flat textile roof Consideration of dynamic wind effects is necessary Consideration of higher vibration modes may be important for widely spanned membrane structures Consideration of added mass effects and aerodynamic damping effects may be important for light-weight membrane structures 24
25 Case Study 3: TK Test Tower for high-speed elevators Site: Rottweil, Germany Height: H = 245 m Structure: reinforced concrete cylinder Skin: permeable membrane facade Airspace between structure and skin 25
26 Skin: Curtain-type permeable nord - sued grid membrane ost - west Crosssection porosity Öffnungsanteil 50% porosity Öffnungsanteil 40% porosity Öffnungsanteil 30% porosity Öffnungsanteil 20% porosity Öffnungsanteil 0% EB ,8 25,
27 Wind tunnel tests: Aeroelastic models of tower well-known: Slender cylindrical structure prone to across-wind vibrations caused by wind (vortex shedding) Question (beside wind loads): Is there an impact of curtain-type grid membrane facade on suspectibility to wind vibrations? Measurements of dynamic response in wind tunnel using aero-elastic model of tower Without membrane facade With (nearby) closed membrane facade With permeable membrane facade 27
28 Impact of membrane facade on across-wind vibrations of total structure caused by wind 100% 90% 80% 28
29 Conclusion Case Study 3: TK Test Tower Advantages of curtain-type permeable membrane facade: More interesting appearance of tower Reduction of asymmetric solar heating of concrete Reduction of across-wind vibrations caused by wind due to helix shape and permeability (including air space) of membrane facade 29
30 Outlook: Numerical Fluid-Structure-Interaction (FSI) Computation In theory, FSI could be fully accounted for using two techniques: 1. Full aeroelastic model in wind tunnel only possible for relatively simple modal shapes, but in general not feasible, especially if membrane itself shows significant vibration modes 2. Full numerical FSI computation still extremely high computational effort, sometimes possible for selected configurations and over short simulation times*** In general, exactly accounting for FSI in either way is still prohibitively expensive and would only be profitable in very few, very special cases. *** Example: FSI for umbrella project Calculation time on high performance computing cluster (HPC) 768 cores Calculation time: 4 weeks for 600 seconds in full-scale Equivalent wind tunnel time: <10 seconds 30
31 Conclusion Wind effects often are decisive for textile structures design Wind tunnel testing is still the most exact and affordable tool to gather raw data (simultaneously measured wind pressure time series) Subsequent dynamic and statistical computations are essential in order to obtain optimized and safe load distributions for the structural engineer The more the wind engineer is involved in the structural planning from an early stage, the more optimization is possible Canopy Roof, Rotterdam, Netherlands Gulf Shade, Canopy in Riad, Saudi Arabia Canopy, Aarau, Switzerland 31
32 THANKS FOR YOUR ATTENTION 32
boundary layer wind flow. Measured wind pressures were expanded from limited measurement points to all the structural nodes using the orthonormal coor
Internal stresses in cladding support members of long-span arched roof under wind load hibin Ding a, Yukio Tamura a, Akihito Yoshida a a Tokyo Polytechnic University, Iiyama 1583, Atsugi, Kanagawa, Japan
More informationMulti-scale methodology to assess wind loads on building louvers
8 th International Colloquium on Bluff Body Aerodynamics and Applications Northeastern University, Boston, Massachusetts, USA June 7-11, 2016 BBAA VIII Multi-scale methodology to assess wind loads on building
More informationAERODYNAMIC RESPONSE OF LONG SPAN CABLE STAYED CONCRETE BRIDGE
AERODYNAMIC RESPONSE OF LONG SPAN CABLE STAYED CONCRETE BRIDGE FX. Supartono *) ABSTRACT This paper presents the result of aerodynamic study and wind tunnel test carried out on Melak Bridge. Being located
More informationXyston Inn. NY. Proposal. Xiaodong Jiang. Structure Option. Advisor: Dr. Linda Hanagan
Proposal Xiaodong Jiang Structure Option Advisor: Dr. Linda Hanagan December 12, 2014 Executive Summary Xyston Inn is a 17-story hotel building that will be located in Brooklyn, New York. The design of
More informationWind Tunnel Applications for Buildings
Wind Tunnel Applications for Buildings Presented by: Jim Swanson, Halvorson and Partners Donald Scott, PCS Structural Solutions Jon Galsworthy, RWDI Add Company Logo Here Outline 1. Introduction 2. ASCE7
More informationStatic wind loads on adjacent cooling towers considering flow interference
Bauhaus Summer School in Forecast Engineering: Global Climate change and the challenge for built environment 17-29 August 2014, Weimar, Germany Static wind loads on adjacent cooling towers considering
More informationWIND TUNNEL STUDIES AND THEIR VALIDATIONS WITH FIELD MEASUREMENTS FOR A SUPER-TALL BUILDING
The Seventh Asia-Pacific Conference on Wind Engineering, November 8-12, 2009, Taipei, Taiwan WIND TUNNEL STUDIES AND THEIR VALIDATIONS WITH FIELD MEASUREMENTS FOR A SUPER-TALL BUILDING Q.S. Li 1, Jiming
More informationA NEW VIBRATION DAMPING FACILITY FOR STEEL CHIMNEYS
Gerb_Chimney.doc - 1 - Prof. Dr. Klein A NEW VIBRATION DAMPING FACILITY FOR STEEL CHIMNEYS H.W. Klein University of Paderborn, now FH Südwestfalen -University of Applied Sciences, Meschede Germany W. Kaldenbach
More informationAeroelastic Wind-Tunnel Testing Technique Revisited
ctbuh.org/papers Title: Author: Subject: Keyword: Aeroelastic Wind-Tunnel Testing Technique Revisited Risto Kontturi Wind Engineering Wind Publication Date: 2005 Original Publication: Paper Type: CTBUH
More informationXyston Inn. NY. Proposal. Xiaodong Jiang. Structure Option. Advisor: Dr. Linda Hanagan
Proposal Xiaodong Jiang Structure Option Advisor: Dr. Linda Hanagan December 12, 2014 Executive Summary Xyston Inn is a 17-story hotel building that will be located in Brooklyn, New York. The design of
More informationFull Paper Proc. of Int. Conf. on Advances in Civil Engineering 2012
Behaviour of R.C.C. Tall Buildings Having Different Shapes Subjected to Wind Load Prof. Sarita Singla 1, Taranjeet Kaur 2, Megha Kalra 3 and Sanket Sharma 4 1 Email:ssaritasingla@yahoo.com 2 Baddi University/Civil
More informationCFD/FEM Based Analysis Framework for Wind Effects on Tall Buildings in Urban Areas
2017 2nd International Conference on Industrial Aerodynamics (ICIA 2017) ISBN: 978-1-60595-481-3 CFD/FEM Based Analysis Framework for Wind Effects on Tall Buildings in Urban Areas Qiao Yan, Dalong Li,
More informationSET PROJECT STRUCTURAL ANALYSIS OF A TROUGH MODULE STRUCTURE, IN OPERATION AND EMERGENCY Luca Massidda
SET PROJECT STRUCTURAL ANALYSIS OF A TROUGH MODULE STRUCTURE, IN OPERATION AND EMERGENCY Luca Massidda Table of Contents Introduction... 2 Finite element analysis... 3 Model description... 3 Mirrors...
More informationEngr. Thaung Htut Aung M. Eng. Asian Institute of Technology Deputy Project Director, AIT Consulting
Engr. Thaung Htut Aung M. Eng. Asian Institute of Technology Deputy Project Director, AIT Consulting Selection of Structural systems Load paths Materials Approximate sizing of members Primary mechanisms
More informationPREDICTION OF SEISMIC TORSIONAL EFFECTS IN TALL SYMMETRIC BUILDINGS
PREDICTION OF SEISMIC TORSIONAL EFFECTS IN TALL SYMMETRIC BUILDINGS C. Justine Jose, T. P. Somasundaran & V. Mustafa Civil Engineering Department, National Institute of Technology Calicut, Kozhikode, Kerala-673601,
More informationTacoma Narrows Bridge
Tacoma Narrows Bridge Structure description: The bridge is a three-span suspension bridge (335m-853m-335m). The towers are 130 meters high. The deck consists of a section with steel beams of 2.45 m thickness,
More informationDYNAMIC WIND LOADING OF H-SHAPED TALL BUILDINGS
The Seventh Asia-Pacific Conference on Wind Engineering, November 8-12, 2009, Taipei, Taiwan DYNAMIC WIND LOADING OF H-SHAPED TALL BUILDINGS K. M. Lam 1, S. Y. Wong 1 and A. P. To 2 1 Department of Civil
More informationVibration control system with digitally adjustable electromagnetic damping and stiffness
Southern Cross University epublications@scu 23rd Australasian Conference on the Mechanics of Structures and Materials 214 Vibration control system with digitally adjustable electromagnetic damping and
More informationTHE PREDICTION OF WIND LOADS ON BUILDING ATTACHMENTS
THE PREDICTION OF WIND LOADS ON BUILDING ATTACHMENTS C. Mans 1, G. A. Kopp, D. Surry Boundary Layer Wind Tunnel Laboratory The University of Western Ontario, London, Ontario, Canada, N6A 5B9 1 Corresponding
More informationPerformance of the Acrylife Roof Vent
Performance of the Acrylife Roof Vent Murray J. Morrison, PhD, Anne D. Cope, PhD, P.E., Timothy A. Reinhold, PhD, P.E. Report: IBHS-12XX01 August 31, 2012 Prepared for: Acrylife 1165 Stafford Umberger
More informationResponse Analysis of an RC Cooling Tower Under Seismic and Windstorm Effects D. Makovička
Response Analysis of an RC Cooling Tower Under Seismic and Windstorm Effects D. Makovička The paper compares the RC structure of a cooling tower unit under seismic loads and under strong wind loads. The
More informationWind Tunnel Applications for Buildings
Wind Tunnel Applications for Buildings Presented by: Jim Swanson, Halvorson and Partners Donald Scott, PCS Structural Solutions Jon Galsworthy, RWDI Add Company Logo Here Outline 1. Introduction 2. ASCE7
More informationWind loads at solar and photovoltaic modules for large plants
Ruscheweyh Consult GmbH Aachen Veröffentlichung Wind loads at solar and photovoltaic modules for large plants Hans Ruscheweyh, Reiner Windhövel Ruscheweyh Consult GmbH, Teichstr. 8, Aachen, Germany, info@ruscheweyh.de
More informationBenchmark Buildings for an International HFBB Comparison
Benchmark Buildings for an International HFBB Comparison Introduction The High Frequency Base Balance (HFBB) (also known as the High-Frequency Force Balance (HFFB)), has been widely used as a wind-tunnel
More informationThis point intends to acquaint the reader with some of the basic concepts of the earthquake engineer:
Chapter II. REVIEW OF PREVIOUS RESEARCH II.1. Introduction: The purpose of this chapter is to review first the basic concepts for earthquake engineering. It is not intended to review the basic concepts
More informationS T R U C T U R. Practical Solutions. magazine. Supplemental Damping and Using Tuned Sloshing Dampers. Tuned Sloshing Dampers
Practical Solutions solutions for the practicing structural engineer Supplemental Damping and Using Tuned Sloshing Dampers By Jamieson K. Robinson P.Eng., Scott L. Gamble P.Eng., and Bujar M. Myslimaj
More informationEVALUATION OF HIGHRISE BUILDING MODEL USING FUNDAMENTAL FREQUENCY MEASUREMENTS
EVALUATION OF HIGHRISE BUILDING MODEL USING FUNDAMENTAL FREQUENCY MEASUREMENTS ABSTRACT Liga Gaile *, Normunds Tirans **, Jans Velicko ** * Riga Technical University, Department of Structural Analysis
More informationTransactions, SMiRT-22 San Francisco, California, USA - August 18-23, 2013 Division V
Transactions, SMiRT- San Francisco, California, USA - August 8-, SIMPLIFIED MODELING OF EFFECTS OF CONCRETE CRACKING ON OUT-OF-PLANE VIBRATIONS OF FLOORS Luben Todorovski, Mahmoud Khoncarly, Dan M Ghiocel,
More informationComparative study of wind tunnel test results to international and Egyptian design codes
Comparative study of wind tunnel test results to international and Egyptian design codes *Chang- Abdulmonem A. Badri 1), *Manar M. Hussein 2) and Walid A. Attia 3) 1), 2), 3) 1 Department of Structural
More informationInterrelation of Dynamic Response and Geometry of Short Steel Chimneys Harshal Deshpande 1, Roshni john2 Shweta motarkar3
Interrelation of Dynamic Response and Geometry of Short Steel Chimneys Harshal Deshpande 1, Roshni john Shweta motarkar 1 PG Student, Dept of Civil Engg, Saraswati College of Engineering, Kharghar, India,
More informationUrban Space Regeneration Design using architectural minimal structure (old market place regeneration using tensile structure)
Urban Space Regeneration Design using architectural minimal structure (old market place regeneration using tensile structure) Research Objectives Tensile Structures Definition History Shading in Urban
More informationSEISMIC SOIL-STRUCTURE INTERACTION (SSI) EFFECTS FOR A DIFFERENT TYPE OF BUILDINGS IN DENSE URBAN AREA
SEISMIC SOIL-STRUCTURE INTERACTION (SSI) EFFECTS FOR A DIFFERENT TYPE OF BUILDINGS IN DENSE URBAN AREA Ovidiu BOGDAN 1, Dan M. GHIOCEL 2 and Dan CRETU 3 ABSTRACT The paper presents the results of a project
More informationPERFORMANCE OPTIMIZATION OF TALL BUILDINGS SUBJECTED TO WIND AN INDIAN SCENARIO
The Eighth Asia-Pacific Conference on Wind Engineering, December 10 14, 2013, Chennai, India ABSTRACT PERFORMANCE OPTIMIZATION OF TALL BUILDINGS SUBJECTED TO WIND AN INDIAN SCENARIO Aswin Kumar 1*, Rahul
More informationDYNAMIC CHARACTERISTICS ASSESSMENT OF STEEL BEAM-COLUMN CONNECTIONS WITH FLOOR SLAB
10NCEE Tenth U.S. National Conference on Earthquake Engineering Frontiers of Earthquake Engineering July 21-25, 2014 Anchorage, Alaska DYNAMIC CHARACTERISTICS ASSESSMENT OF STEEL BEAM-COLUMN CONNECTIONS
More informationRESPONSE OF GROUND SUPPORTED CYLINDRICAL TANKS TO HARMONIC LOADING
RESPONSE OF GROUND SUPPORTED CYLINDRICAL TANKS TO HARMONIC LOADING Asha Joseph 1 and Glory Joseph 2 1 Research Scholar, Cochin University of Science and Technology, Kerala 2 Associate Professor, Cochin
More informationCHAPTER III DYNAMIC BEHAVIOR OF A LABORATORY SPECIMEN
CHAPTER III DYNAMIC BEHAVIOR OF A LABORATORY SPECIMEN To address the vibration response of a long span deck floor system, an experiment using a specimen that resembles the conditions found in the in-situ
More informationS. Gandhi *1, Syed Rizwan 2
2017 IJSRSET Volume 3 Issue 3 Print ISSN: 2395-1990 Online ISSN : 2394-4099 Themed Section: Engineering and Technology Analysis and Design of Tall Building (G+21) Using ETABS S. Gandhi *1, Syed Rizwan
More informationTHE EXTENDED N2 METHOD IN SEISMIC DESIGN OF STEEL FRAMES CONSIDERING SEMI-RIGID JOINTS
THE EXTENDED N2 METHOD IN SEISMIC DESIGN OF STEEL FRAMES CONSIDERING SEMI-RIGID JOINTS Paulina KROLO 1, Mehmed CAUSEVIC 2 and Mladen BULIC 3 ABSTRACT In this paper the nonlinear static seismic analysis
More informationCorrelation of Geometry and Dynamic Response of Self- Supported Short Circular Steel Stacks
Correlation of Geometry and Dynamic Response of Self- Supported Short Circular Steel Stacks Harshal Deshpande 1, Post Graduate Student in Structural Engineering, Saraswati College of Engineering, Kharghar
More informationCHAPTER 4. 1:6-Scale Frame: Stiffness and Modal Testing 4.1 OVERVIEW
CHAPTER 4 1:6-Scale Frame: Stiffness and Modal Testing 4.1 OVERVIEW A 1:6-scale steel moment frame was designed for shaking-table experiments described in Chapter 5 based on Drain-2DX (DRAIN) analyses.
More informationDesign of a new wind tunnel facility at Industrial Engineering School in Badajoz (Spain)
Design of a new wind tunnel facility at Industrial Engineering School in Badajoz (Spain) F. Zayas Hinojosa Department of Electronics and Electromechanical Engineering, University of Extremadura, Spain
More informationDetermination of damage location in RC beams using mode shape derivatives
Determination of damage location in RC beams using mode shape derivatives Z. Ismail, H. Abdul Razak, A.G. Abdul Rahman Periodic structural condition monitoring of reinforced concrete structures is necessary
More informationSEISMIC DESIGN CHARACTERISTICS OF THE NEW BUILDING FOR DIGITAL AUTOMATION EQUIPMENT FOR LOVIISA NUCLEAR POWER PLANT
13 th World Conference on Earthquake Engineering Vancouver, B.C., Canada August 1-6, 2004 Paper No. 2803 SEISMIC DESIGN CHARACTERISTICS OF THE NEW BUILDING FOR DIGITAL AUTOMATION EQUIPMENT FOR LOVIISA
More informationVibration-Induced Fatigue Failure of Discharge Bottle Fitting Connections A Case Study
Vibration-Induced Fatigue Failure of Discharge Bottle Fitting Connections A Case Study By Ramin Rahnama Team Lead Wood Group Vibration, Dynamics & Noise (formerly BETA Machinery Analysis) Paul Crowther
More informationInterference of Wind Turbines with Different Yaw Angles of the Upstream Wind Turbine
42nd AIAA Fluid Dynamics Conference and Exhibit 25-28 June 2012, New Orleans, Louisiana AIAA 2012-2719 Interference of Wind Turbines with Different Yaw Angles of the Upstream Wind Turbine Ahmet Ozbay 1,
More informationStructural Design and Optimization of Long-Span Ultra-Slim Composite Floor for Super Tall Residence
Structural Design and Optimization of Long-Span Ultra-Slim Composite Floor for Super Tall Residence *Rong He 1), Guo Ding 2), Yue Yang 3) and Liwei Ye 4) 1), 2), 3) Tongji Architectural Design (Group)
More informationINTERNATIONAL JOURNAL OF PURE AND APPLIED RESEARCH IN ENGINEERING AND TECHNOLOGY
INTERNATIONAL JOURNAL OF PURE AND APPLIED RESEARCH IN ENGINEERING AND TECHNOLOGY A PATH FOR HORIZING YOUR INNOVATIVE WORK SPECIAL ISSUE FOR NATIONAL LEVEL CONFERENCE "SUSTAINABLE TECHNOLOGIES IN CIVIL
More informationVibration Isolation Systems
Vibration Isolation Systems...we design and manufacture individual solutions Vibration Isolation Air Springs Steel Spring Isolators Level Control Systems Vibration Engineering Vibration Isolation Systems
More informationPart III Special Topics of Bridges
ENCE717 Bridge Engineering Special Topics of Bridges III Chung C. Fu, Ph.D., P.E. (http: www.best.umd.edu) 1 Part III Special Topics of Bridges 6. Dynamic/Earthquake Analysis (17.0) i. Basics of Bridge
More informationSeismic Analysis and Design of Vertically Irregular RC Building Frames
Seismic Analysis and Design of Vertically Irregular RC Building Frames Himanshu Bansal 1, Gagandeep 2 1 Student (M.E.), PEC University of Technology, Civil Department, Chandigarh, India 2 Student (M.E.),
More informationProgressive Collapse Analysis of RC Buildings using Linear Static and Linear Dynamic Method
Progressive Collapse Analysis of RC Buildings using Linear Static and Linear Dynamic Method Bhavik R. Patel M.Tech (Civil-STRUCTURAL DESIGN), Faculty of Technology, CEPT University Ahmedabad, Gujarat,
More informationCOMPARATIVE SEISMIC ANALYSIS OF OVERHEAD CRANE ON STEEL FRAME CARRYING STRUCTURE: EVALUATION OF ADEQUATE EQUIPMENT-STRUCTURE INTERACTION MODELING
COMPARATIVE SEISMIC ANALYSIS OF OVERHEAD CRANE ON STEEL FRAME CARRYING STRUCTURE: EVALUATION OF ADEQUATE EQUIPMENT-STRUCTURE INTERACTION MODELING Andrea GODOY 1, Frédéric BARBIER, Charisis CHATZIGOGOS
More informationACCURATE LINEAR AND NONLINEAR SEISMIC SSI ANALYSIS BASED ON ANSYS FE MODELING USING EXTENDED SASSI METHODOLOGY
Transactions, SMiRT-24 II, Paper 468 ACCURATE LINEAR AND NONLINEAR SEISMIC SSI ANALYSIS BASED ON ANSYS FE MODELING USING EXTENDED SASSI METHODOLOGY Dan M. Ghiocel 1, Mike Saremi 2 1 Chief of Engineering
More informationExecutive Summary Building Description: Introduction... 13
Table of Contents Executive Summary... 2 Building Description:... 2 Report Summary:... 2 Introduction... 3 Building Description:... 3 Current Framing Layout... 4 Report Topics:... 4 Loads and Load Cases...
More informationThe University of Liège Wind Tunnel Facility
The University of Liège Wind Tunnel Facility Technical description The University of Liège Wind Tunnel Facility Technical description December 2009-1/27 The University of Liège Wind Tunnel Facility Technical
More informationInternational Journal of Advance Engineering and Research Development
Scientific Journal of Impact Factor (SJIF): 4.72 International Journal of Advance Engineering and Research Development Volume 4, Issue 7, July -2017 e-issn (O): 2348-4470 p-issn (P): 2348-6406 Pushover
More informationMSC NASTRAN AEROELASTICITY FOR AIRCRAFT CERTIFICATION
SESSION TITLE WILL BE COMPLETED BY MSC SOFTWARE MSC NASTRAN AEROELASTICITY FOR AIRCRAFT Robert Lind (TLG Aerospace, USA); Steve Muenzberg (TLG Aerospace, USA) Robert Lind, Engineering Manager SUMMARY MSC
More informationCase Study: Challenges of a Single-layer Reticulated Dome
Case Study: Challenges of a Single-layer Reticulated Dome Naveed Anwar, Pramin Norachan, Thaung Htut Aung AIT Consulting, Asian Institute of Technology, Bangkok, Thailand Contact: nanwar@ait.asia Abstract
More informationEVALUATION OF NONLINEAR STATIC PROCEDURES FOR SEISMIC DESIGN OF BUILDINGS
EVALUATION OF NONLINEAR STATIC PROCEDURES FOR SEISMIC DESIGN OF BUILDINGS By H.S. Lew 1 and Sashi K. Kunnath Presented at the rd Joint Meeting of the UJNR Panel on Wind and Seismic Effects ABSTRACT This
More informationNON-LINEAR STATIC PUSHOVER ANALYSIS FOR MULTI-STORED BUILDING BY USING ETABS
NON-LINEAR STATIC PUSHOVER ANALYSIS FOR MULTI-STORED BUILDING BY USING ETABS Polupalli Victor Paul 1, K Sampath Kumar 2 1 PG Student, Dept of Civil Engineering, Nova College of Engineering & Technology,
More informationFEDERATION TOWER MOSCOW DIFFERENT ROOM CLIMATES UNDER ONE ROOF
FEDERATION TOWER MOSCOW DIFFERENT ROOM CLIMATES UNDER ONE ROOF Oliver Baumann 1, and Claudius Reiser 1/2 1 Ebert & Baumann Consulting Engineers, Washington, D.C. 2 Ebert-Ingenieure GmbH &Co. KG, Munich,
More informationFlexible Structural Façade
Ir. A.P.H.W. Habraken Faculty of Building and Architecture Eindhoven University of Technology Copyright with the authors. All rights reserved. Flexible Structural Façade Arjan Habraken, Assistant Professor
More informationDYNAMIC TESTING OF FULL-SCALE 11-STORY RC BUILDING AND ITS 3-STORY STRUCTURAL PART: COMPARISON OF THE RESULTS AND SEISMIC RESISTANCE ESTIMATION
DYNAMIC TESTING OF FULL-SCALE 11-STORY RC BUILDING AND ITS 3-STORY STRUCTURAL PART: COMPARISON OF THE RESULTS AND SEISMIC RESISTANCE ESTIMATION ABSTRACT : I. Iskhakov and Y. Ribakov Dept. of Civil Engineering,
More informationDynamic Analysis of High Rise Flat Plate Building with Different Retrofitting Systems
EUROPEAN ACADEMIC RESEARCH Vol. I, Issue 11/ February 2014 ISSN 2286-4822 www.euacademic.org Impact Factor: 3.1 (UIF) DRJI Value: 5.9 (B+) Dynamic Analysis of High Rise Flat Plate Building with Different
More informationOptimization of Wind Loads Affecting Skyscrapers using ANSYS
Optimization of Wind Loads Affecting Skyscrapers using ANSYS Kavana B C 1, M S kalappa 2 1MTech student, dept of civil Engineering, MCE, Hassan, Karnataka, India 2Professor, dept of civil Engineering,
More informationAPPLYING COMPUTATIONAL FLUID DYNAMICS TO ARCHITEC- TURAL DESIGN DEVELOPMENT
APPLYING COMPUTATIONAL FLUID DYNAMICS TO ARCHITEC- TURAL DESIGN DEVELOPMENT Strategy and Implementation JIN-YEU TSOU Department of Architecture, Chinese University of Hong Kong Sha Tin, New Territories,
More informationTorsional and Seismic Behavior of Shear Wall Dominant Flat Plate Buildings
Torsional and Seismic Behavior of Shear Wall Dominant Flat Plate Buildings Ramya S R 1, Dr. P M Ravindra 2 1M. Tech Student, Department of Civil Engineering, Bangalore Institute of Technology, Bengaluru-
More informationSTUDY ON EFFECTS OF P-DELTA ANALYSIS ON RC STRUCTURES
STUDY ON EFFECTS OF P-DELTA ANALYSIS ON RC STRUCTURES Bhavani Shankar 1, Dheekshith K 2, Naveen Kumar 3 1,2 Assistant Professor, Dept. of Civil Engg., S.S.E, Mukka, Karnataka, India 3PG Student, Dept.
More informationAmbient Vibration Testing of Three Unreinforced Brick Masonry Buildings in Vancouver, Canada
Ambient Vibration Testing of Three Unreinforced Brick Masonry Buildings in Vancouver, Canada Abstract Martin Turek 1, Katherine Thibert 1, Carlos Ventura 2 and Steven Kuan 3 (1) Graduate Students (2) Professor
More informationBraced deep excavations in soft ground
1 Introduction Braced deep excavations in soft ground Halim and Wong presented a paper in a publication called Underground Singapore 2005. The title of the paper is Evaluation of Modified Cam Clay Parameters
More informationCOMPUTER AIDED DESIGN AND ANALYSIS OF RC FRAME BUILDINGS SUBJECTED TO EARTHQUAKES
COMPUTER AIDED DESIGN AND ANALYSIS OF RC FRAME BUILDINGS SUBJECTED TO EARTHQUAKES ABSTRACT O. El Kafrawy 1, M. Yousuf 1 and A. Bagchi 2 Computer use in structural analysis and design dates back a number
More informationAn Introduction to Spread Footings and Mat Foundations
An Introduction to Spread Footings and Mat Foundations J. Paul Guyer, P.E., R.A. Editor Paul Guyer is a registered civil engineer, mechanical engineer, fire protection engineer, and architect with over
More informationComparative Study of Static and Dynamic Seismic Analysis of a Multistoried Building
IJSTE - International Journal of Science Technology & Engineering Volume 2 Issue 01 July 2015 ISSN (online): 2349-784X Comparative Study of Static and Dynamic Seismic Analysis of a Multistoried Building
More informationAl Islam Textile Ltd.
Al Islam Textile Ltd. 9 Kornopara,Savar,Dhaka-1340 (23.824207N, 90.256342E) 27 APRIL 2014 1 2 Observations Item 1 observation Column loads in excess of design loads Verify concrete strengths in columns
More informationR. J. McNamara, S.E.
USE OF MOTION AMPLIFICATION DEVICES AND FLUID DAMPERS TO REDUCE THE WIND INDUCED RESPONSE OF TALL BUILDINGS by R. J. McNamara, S.E. McNamara/Salvia, Inc. Boston, MA 02110 USE OF MOTION AMPLIFICATION DEVICES
More informationLoad Bearing Mechanism of Piled Raft Foundation during Earthquake
Proceedings Third UJNR Workshop on Soil-Structure Interaction, March 9-,, Menlo Park, California, USA. Load Bearing Mechanism of Piled Raft during Earthquake Shoichi Nakai a), Hiroyuki Kato a), Riei Ishida
More informationModeling and Analysis of Acoustic Emissions and Structural Vibration in a Wind Turbine
Modeling and Analysis of Acoustic Emissions and Structural Vibration in a Wind Turbine CH. V. N. Badrinath & P. Kranthi Chakravarthy R. M. K Engineering College, R. S. M Nagar, Kavaraipettai - 601206 E-mail
More informationDynamic Stability of Elastomeric Bearings at Large Displacement
Dynamic Stability of Elastomeric Bearings at Large Displacement A. Masroor, J. Sanchez, G. Mosqueda University at Buffalo, NY, USA K. L. Ryan University of Nevada, Reno, USA SUMMARY: Bearings used in the
More informationForced vibration testing of a thirteen storey concrete building
Forced vibration testing of a thirteen storey concrete building F. Shabbir, & P. Omenzetter Department of Civil and Environmental Engineering, University of Auckland, Auckland, New Zealand 2008 NZSEE Conference
More informationA Promising Approach in the World: Tensile Structures Roofing
International Journal of Engineering Research and Development, Vol.7, No.3, 015, All in One Conference Special Issue 1 A Promising Approach in the World: Tensile Structures Roofing Talha Ekmekyapar, Alaa
More informationSabah Shawkat Cabinet of Structural Engineering 2017
3.1-1 Continuous beams Every building, whether it is large or small, must have a structural system capable of carrying all kinds of loads - vertical, horizontal, temperature, etc. In principle, the entire
More informationfifteen design for lateral loads Lateral Load Resistance Load Direction Lateral Load Resistance
APPLIED ARCHITECTURAL STRUCTURES: STRUCTURAL ANALYSIS AND SYSTEMS DR. ANNE NICHOLS FALL 2013 lecture fifteen design for lateral loads Lateral Load Resistance stability important for any height basic mechanisms
More informationFluid Viscous Dampers to reduce Wind-induced Vibrations in Tall Buildings
Fluid Viscous Dampers to reduce Wind-induced Vibrations in Tall Buildings Abstract R.J. McNamara, SE McNamara / Salvia Inc. 160 Federal Street, 16 th Floor Boston, MA 02110 +1 617 737 0040 Douglas P. Taylor,
More informationEffect of plastic hinge, soil nonlinearity and uplift on earthquake energy in structures
Effect of plastic hinge, soil nonlinearity and uplift on earthquake energy in structures M. Sarrafzadeh, E. Lim, X. Qin & N. Chouw Department of Civil and Environmental Engineering, the University of Auckland,
More informationNonlinear Dynamic Analysis a Step Advance
Nonlinear Dynamic Analysis a Step Advance in Assessing the Vulnerability of Buildings Editor s note: The strength of an earthquake catastrophe model in producing to Earthquake reliable loss estimates lies
More informationModelling and Analysis of Irregular Geometrical Configured RCC Multi- Storey Building Using Shear Wall
Kalpa Publications in Civil Engineering Volume 1, 2017, Pages 388 397 ICRISET2017. International Conference on Research and Innovations in Science, Engineering &Technology. Selected papers in Civil Engineering
More informationGoverning Loads for Design of A tall RCC Chimney
IOSR Journal of Mechanical and Civil Engineering (IOSR-JMCE) ISSN: 78-684, PP: -9 www.iosrjournals.org Governing Loads for Design of A tall RCC Chimney M. G. SAIK, MIE,.A.M.I. KAN ( Department of Applied
More informationDYNAMIC ANALYSIS OF STEEL TUBE STRUCTURE WITH BRACING SYSTEMS
DYNAMIC ANALYSIS OF STEEL TUBE STRUCTURE WITH BRACING SYSTEMS Dhanapalagoud Patil 1, Naveena M P 2 1 Student, Structural Engineering, MVJ College of Engg, Karnataka, India 2 Assistant Professor, Structural
More informationReliability of Using Modal Curvature Method in Long Span Cable Stayed Bridges
Reliability of Using Modal Curvature Method in Long Span Cable Stayed Bridges Dhanya S Remesan 1, Rahul Leslie 2, Ashok Mathew 3 1 M Tech Scholar, Department of Civil Engineering, Sree Buddha College of
More informationBuilding in Beijing. Steel provides the support for two new high-profile atriums in China s capital.
international projects Building in Beijing By Mark Sarkisian, P.E., S.E., Neville Mathias, P.E., S.E., and Aaron Mazeika, P.E. Steel provides the support for two new high-profile atriums in China s capital.
More informationNonlinear Analysis and Design of a Guyed Mast: Comparison of Two Design Proposals
Advanced Materials Research Online: 2010-12-06 ISSN: 1662-8985, Vols. 163-167, pp 20-24 doi:10.4028/www.scientific.net/amr.163-167.20 2011 Trans Tech Publications, Switzerland Nonlinear Analysis and Design
More informationDesign of large scale wind turbine towers in seismic areas
Design of large scale wind turbine towers in seismic areas C.C. Baniotopoulos, I. Lavassas, G. Nikolaidis, P.Zervas Institute of Metal Structures, Dept. of Civil Engineering, A.U.Th., Thessaloniki, Greece
More informationComparative Analysis and Design of Flat and Grid Slab System with Conventional Slab System
Comparative Analysis and Design of Flat and Grid Slab System with Conventional Slab System Syed Abdul Qavi 1, Syed Khaleelullah Shah Quadri 2 Syed Farrukh Anwar 3 1 PG Student, M.tech in Structural engineering,
More informationANALYSIS OF WIND & EARTHQUAKE LOAD FOR DIFFERENT SHAPES OF HIGH RISE BUILDING
INTERNATIONAL JOURNAL OF CIVIL ENGINEERING AND TECHNOLOGY (IJCIET) International Journal of Civil Engineering and Technology (IJCIET), ISSN 0976 6308 (Print), ISSN 0976 6308 (Print) ISSN 0976 6316(Online)
More informationTesting and modelling on an energy absorbing rock bolt
Testing and modelling on an energy absorbing rock bolt A. Ansell Department of Structural Engineering, Royal Institute of Technology, Stockholm, Sweden Abstract Dynamic loads on underground structures,
More informationfifteen design for lateral loads Lateral Load Resistance Load Direction Lateral Load Resistance
APPLIED ARCHITECTURAL STRUCTURES: STRUCTURAL ANALYSIS AND SYSTEMS DR. ANNE NICHOLS SPRING 2017 lecture fifteen design for lateral loads Lateral Load Resistance stability important for any height basic
More information1. INTRODUCTION 1.1 FLAT SLAB. 275 P a g e
Sandesh D. Bothara, Dr.Valsson Varghese / International Journal of Engineering Research and Applications Dynamic Analysis Of Special Moment Resisting Frame Building With Flat Slab And Grid Slab *Sandesh
More informationStructural Redesign Gravity System
Redesign Gravity System Design Considerations A composite floor system was used for this design to maximize the efficiency of the material being used. This type of system requires less material and provides
More informationEQUIVALENT UNIFORM DAMPING RATIOS for Irregular in Height Concrete / Steel Structural systems
EUROSTEEL 2008, 3-5 September 2008, Graz, Austria 1485 EQUIVALENT UNIFORM DAMPING RATIOS for Irregular in Height Concrete / Steel Structural systems A.V. Papageorgiou a, C.J. Gantes a a National Technical
More informationCFD and Wind Tunnel Study of the Performance of a Multi- Directional Wind Tower with Heat Transfer Devices
Available online at www.sciencedirect.com ScienceDirect Energy Procedia 75 (2015 ) 1692 1697 The 7 th International Conference on Applied Energy ICAE2015 CFD and Wind Tunnel Study of the Performance of
More information