Article 324: Flat Conductor Cable (FCC) 1.! Type FCC (flat conductor cable) cable wiring system is designed for installations under.

Size: px
Start display at page:

Download "Article 324: Flat Conductor Cable (FCC) 1.! Type FCC (flat conductor cable) cable wiring system is designed for installations under."

Transcription

1 Part F: Code Book Questions Article 324: Flat Conductor Cable (FCC) 1.! Type FCC (flat conductor cable) cable wiring system is designed for installations under.! (a) tile! (c) carpet squares! (b) carpet! (d) concrete 2.! Voltage between the ungrounded and the grounded conductor on FCC cable shall not exceed! volts.! (a) 50! (c) 300! (b) 150! (d) ! FCC cable can have individual branch circuits with a rating not exceeding amperes.! (a) 15! (c) 25! (b) 20! (d) 30 4.! FCC carpet squares that are adhered to the floor shall be attached with.! (a) tacking strip! (c) glue! (b) release-type adhesive! (d) any of these 5.! Metal components of the FCC system shall be.! (a)!insulated from contact with corrosive substances! (b)!coated with corrosion-resistant materials! (c)! corrosion-resistant! (d)!any of these 6.! When installing a type FCC system under carpet squares, not more than crossings of cable! runs shall be permitted at any one point.! (a) 1! (c) 4! (b) 2! (d) 5 7.! All type FCC cable connections shall use connectors identified for their use, installed such that! against dampness and liquid spillage are provided.! (a) electrical continuity! (c) sealing! (b) insulation! (d) all of the above

2 8.! Power feed, grounding connection, and shield system connection between the FCC system!and! other wiring systems shall be accomplished in a.! (a) transition assembly! (b) raceway! (c) trench! (d) none of these 9.! Connection from any grounding conductor of the type FCC cable shall be made to the shield! system at each.! (a) boxes! (c) self-contained device! (b) receptacle housings! (d) all of these 10.!FCC cable shall consist of flat copper conductors, one of which shall be an equipment! grounding conductor.! (a) three! (c) five! (b) four! (d) any of these 11.!Type FCC cable shall be clearly and durably marked with.! (a) material of conductors! (c) ampacity! (b) maximum temperature rating! (d) all of the above Article 326: Integrated Gas Spacer Cable (IGS) 12.!The ampacity of a #250 kcmil IGS (integral gas spacer) cable is amperes.! (a) 119! (c) 215! (b) 168! (d) !The maximum ampacity for a single #500 kcmil conductor in a type IGS cable shall not exceed! amperes.! (a) 119! (c) 206! (b) 168! (d) !The nominal gas pressure for IGS cable insulation shall be pounds per square inch guage.! (a) 5! (c) 15! (b) 10! (d) 20

3 Article 328: Medium Voltage Cable (MV) 15.!Type, medium voltage cable, is a single or multiconductor solid dielectric insulated cable! rated 2001 volts or higher.! (a) MI! (c) MVC! (b) NM! (d) MV 16.!Type MV cables shall be permitted for use on power systems rated up to volts.! (a) 600! (c) 4,160! (b) 2,300! (d) 35, !Type MV cables shall not be used unless identified for the use.! (a) where exposed to direct sunlight! (c) direct buried! (b) in cable trays! (d) all of these Article 330: Metal-Clad Cable (MC) 18.!Type, metal-clad cable, is a factory assembly of one or more conductors, each individually! insulated and enclosed in a metallic sheath of interlocking tape, or a smooth or corrugated tube.! (a) MI! (c) MC! (b) AC! (d) MCC 19.!Type MC cable installed outside of buildings or as aerial cable shall comply with NEC! Article.! (a) ! (c) ! (b) ! (d) none of these 20.!Type MC cable shall not be used.! (a) where subject to physical damage! (c) in concrete! (b) directly buried in the earth! (d) any of these 21.!MI cable shall be permitted. Article 332: Mineral Insulated, Metal-Sheathed Cable (MI)! (a) for services, feeders and branch circuits!! (c) where exposed or concealed! (b) in dry, wet, continuously moist locations! (d) all of the above

4 22.!Which of the following statements about MI cable is correct?! (a)!it may be used in any hazardous (classified) location! (b)!it may be mounted flush on a wall in a wet location! (c)! it shall be supported every 10 feet! (d)!a single run of cable shall not contain more than four quarter bends 23.!For MI cable, bends in the radius of the inner edge of any bend shall not be less than times! the external diameter of the metallic sheath for cable not more than 3/4 in external diameter.! (a) 5! (c) 7! (b) 6! (d) 8 24.!Where MI cable terminates, an end shall be provided immediately after stripping to prevent! the entrance of moisture into the insulation.! (a) bushing! (c) fitting! (b) connector! (d) seal fitting 25.!Ml cable has.! (a)!solid copper conductors! (b)!outer sheath to provide mechanical protection! (c)! an adequate path for grounding purposes! (d)!all of these Article 334: Nonmetallic-Sheathed Cable (NM, NMC, NMS) 31.!Which of the following is true concerning type NM (non-metallic sheathed) cable?! (a)!it may be installed where exposed to corrosive fumes! (b)!it may be fished in air voids in masonry block or tile walls! (c)! it may be embedded in masonry, concrete, or plaster! (d)!it may be covered with plaster, adobe, or similar finish 32.!When passing through a floor NM cable shall be enclosed in a pipe or conduit extending at least! above the floor! (a) 1 inch! (c) 6 inches! (b) 3 inches! (d) 1 foot 33.!NM (nonmetallic sheath cable): If installed in an attic that is not accessible by stairs or permanent! ladder needs to be protected within feet of a scuttle hole.! (a) 2! (b) 3! (c) 6! (d) 10

5 34.!The allowable distance between supports of nonmetallic-sheathed cable shall not exceed feet.! (a) 2! (c) 4! (b) 3-1/2! (d) 4-1/2 35.!Nonmetallic sheath cable shall be supported within of every cabinet, box or fitting.! (a) 6 inches! (c) 2 feet! (b) 12 inches! (d) 4 feet 36.! of insulating material shall be permitted to be used without boxes in exposed cable wiring! and for rewiring of existing buildings.! (a) Switch devices! (c) Tap devices! (b) Outlet devices! (d) any of these 37.!The ampacity of types NM and NMC cable shall be that of conductors.! (a) 60 C! (c) 90 C! (b) 75 C! (d) 140 C 38.!The power conductors in type NMS cable are manufactured in sizes copper.! (a)!#14-#6! (c)! #14-#2! (b)!#14-#4! (d)!#12-#2 39.!The overall covering of type NMC cable shall be.! (a) flame retardant! (c) fungus and corrosion resistant! (b) moisture resistant! (d) all of the above Article 336: Power And Control Tray Cable (TC) 40.!Type TC power and control cable shall be permitted to be used.! (a)!for power, lighting, control, and signal circuits! (b)!in outdoor locations when supported by a messenger wire! (c)! in cable trays! (d)!all of the above

6 Article 338: Service-Entrance Cable (SE, USE) 41.!Type SE service-entrance cables shall be permitted in interior wiring systems where all of the! circuit conductors of the cable are of the type.! (a) cross-linked polymer! (c) thermoplastic! (b) rubber-covered! (d) rubber-covered or thermoplastic 42.!SE cable used to supply shall not be subject to conductor temperatures in excess of the! temperature specified for the type of insulation involved.! (a) lighting! (c) motors! (b) appliances! (d) generators 43.!Type USE service entrance cable identified for underground use in a cabled assembly shall be! permitted to have a concentric conductor applied.! (a) bare copper! (c) bare aluminum! (b) covered metal! (d) covered 44.!If SE or USE cable consists of two or more conductors, one shall be permitted to be.! (a) insulated! (c) tagged! (b) green! (d) uninsulated Article 340: Underground Feeder And Branch-Circuit Cable (UF) 45.!Type UF cable shall be permitted for.! (a) service entrance cable! (c) underground! (b) embedded in concrete! (d) hoistways 46.!Type UF cable shall be permitted for wiring in locations.! (a) wet! (b) dry! (c) corrosive! (d) any of these 47.!The ampacity of type UF cable shall be that of conductors.! (a) 60 F! (c) 75 C! (b) 60 C! (d) 140 C 48.!Type UF cable is manufactured in sizes #14 through.! (a) #4/0! (c) #6! (b) #4! (d) #10

7 49.!The overall covering of UF cable shall be.! (a) flame-retardant!! (c) suitable for direct burial in the earth! (b) moisture, fungus and corrosion resistant!! (d) all of the above Article 342: Intermediate Metal Conduit (IMC) 50.!Where practicable, dissimilar metals in contact anywhere in the system shall be avoided to! eliminate the possibility of.! (a) hysteresis! (c) specific gravity! (b) galvanic action! (d) resistance 51.! fittings and enclosures shall be permitted to be used with IMC.! (a) lead! (c) aluminum! (b) copper! (d) any of these 52.!Where conduit is threaded in the field, a standard conduit cutting die with a inch taper per! foot shall be used.! (a) 1/2! (c) 1! (b) 3/4! (d) 1-1/4 Article 344: Rigid Metal Conduit (RMC) 53.! shall be permitted to be installed in concrete, in direct contact with the earth, or in areas! subject to severe corrosive influences where protected by corrosion protection and judged suitable! for the condition.! (a) PVC! (c) Orangeburg! (b) Ceramic! (d) Rigid Metal Conduit 54.!There shall not be more than the equivalent of quarter bends (360 degrees total) between! pull points.! (a) 2! (c) 4! (b) 3! (d) none of these 55.!All cut ends of (RMC) rigid metal conduit shall be.! (a) threaded! (c) reamed! (b) electrically continuous! (d) cut square

8 56.!Rigid metal conduit size 2 shall be supported every feet.! (a) 10! (c) 14! (b) 12! (d) !Rigid conduit shall be every 10 feet as required by section ! (a) stamped! (c) marked! (b) clearly and durably identified! (d) none of these Article 348: Flexible Metal Conduit (FMC) 58.!The largest conductor permitted in 3/8 flexible conduit is.! (a) #12! (c) #14! (b) #16! (d) #10 59.!How many #12 XHHW conductors can you install in a 3/8 flexible metal conduit with the fitting! outside the conduit?! (a) 0! (c) 2! (b) 1! (d) 3 60.!Flexible metal conduit shall be secured by approved means at intervals not exceeding feet! and within 12 on each side of every outlet box.! (a) 2! (c) 4-1/2! (b) 4! (d) 8 Article 350: Liquidtight Flexible Metal Conduit (LFMC) 61.!Liquidtight flexible metal conduit may be used in which of the following locations?! (a) in areas that are both exposed or concealed! (b)!in areas where the ambient temperature is to be greater than 194 C! (c)! in areas that are subject to physical damage! (d)!in connection areas for gasoline dispensing pumps 62.!Liquidtight flexible metal conduit shall not be permitted.! (a)!in hazardous locations! (b)!in exposed and concealed work! (c)! where temperatures are in excess for which the material is approved! (d)!where installations requires flexibility or protection from liquids, vapors or solids

9 63.!Liquidtight flexible metal conduit is shipped in what sizes (minimum to maximum)?! (a) 1/2 to 4! (c) 3/4 to 5! (b) 1/2 to 6! (d) 1/2 to 2 Article 352: Rigid Nonmetallic Conduit (RNC) 64.!Which of the following is not true regarding rigid nonmetallic conduit?! (a)!extreme cold may cause some nonmetallic conduits to become brittle and therefore more!! susceptible to damage from physical contact.! (b)!rnc can be used to support fixtures.! (c)! RNC can be used in walls, floors and ceilings.! (d)!expansion joints shall be provided to compensate for thermal expansion and contraction. 65.!When installing rigid nonmetallic conduit.! (a)!all joints shall be made with expansion fittings! (b)!all cut ends shall be trimmed inside and outside to remove rough edges! (c)! there shall be support within 2 feet of each box, cabinet! (d)!bending shall be made by an approved bending machine 66.!Rigid nonmetallic conduit has a maximum spacing between supports of feet.! (a) 3! (c) 6! (b) 5! (d) 8 67.!In a straight run of rigid nonmetallic conduit expansion joints are required where the computed! length change due to thermal expansion or contraction is at least inch or more.! (a) 1/8! (b) 1/4! (c) 3/8! (d) 1/2 Article 354: Nonmetallic Underground Conduit With Conductors (NUCC) 68.!Factory assembled nonmetallic conduit (NUCC) with conductors is not permitted.! (a)!in cinder fill! (b)!in exposed locations! (c)! encased or embedded in concrete! (d)!in underground locations subject to severe corrosive influences

10 Article 358: Electrical Metallic Conduit (EMT) 69.!EMT (electrical metallic tubing) shall not be used.! (a)!for exposed work!! (b)!where protected from corrosion solely by enamel! (c)! for concealed work!! (d)!none of these 70.!Aluminum fittings and enclosures shall be permitted to be used with where not subject to! severe corrosive influences.! (a) both ferrous and nonferrous conduits!! (c) electrical nonmetallic tubing! (b) PVC schedule 80 conduit!! (d) steel (EMT) electrical metallic tubing 71.!Minimum and maximum sizes of EMT are except for special installations.! (a) 5/16 to 3! (c) 1/2 to 3! (b) 3/8 to 4! (d) 1/2 to 4 72.!The maximum number of quarter bends in one run of EMT is.! (a) two! (c) five! (b) four! (d) none of these 73.!EMT shall be permitted as an equipment grounding conductor.! (a) true! (b) false!!! Article 360: Flexible Metallic Tubing (FMT) 74.!The radius of bends of 1/2 of flexible metallic tubing (FMT) for flexing use shall not be less than! inches.! (a) 3-1/2! (c) 12-1/2! (b) 4! (d) 17-1/2 75.!The minimum radius of a fixed bend for a 3/4 flexible metallic tubing is inches.! (a)!17-1/2! (c) 10! (b) 12-1/2! (d) 5

11 Article 362: Electrical Nonmetallic Conduit (ENT) 76.!A pliable raceway is a raceway which can be bent with a reasonable force, but without other! assistance.! (a) with heat! (c) by hand! (b) without heat! (d) easily 77.!Electrical nonmetallic tubing is not permitted.! (a)!above a suspended ceiling (with a 15 minute fire rating)! (b)!embedded in concrete! (c)! for direct burial! (d)!concealed in walls, floors and ceilings (with a 15 minute fire rating over three floors) 78.!The voltage limitation for electrical nonmetallic tubing (ENT) is.! (a) 600 volts! (c) 1100 volts! (b) 900 volts! (d) 1200 volts 79.!Electrical nonmetallic tubing (ENT) is permitted to be used in sizes.! (a) 1/2-1! (c) 3/8-3! (b) 1/2-2! (d) 3/ !Electrical nonmetallic tubing shall be clearly and durably marked at least every feet.! (a) 3! (c) 8! (b) 6! (d) 10 Article 366: Auxilliary Gutters 81.!Metallic auxiliary gutters shall be permitted to supplement wiring spaces at meter centers,! distribution centers, switchboards, and similar points of wiring systems and may enclose.! (a) electric wires! (c) busbars! (b) cables! (d) any of these 82.!An auxiliary gutter shall not extend a greater distance than feet beyond the equipment which! it supplements.! (a) 10! (c) 30! (b) 20! (d) 40

12 83.!How much current is allowed on a copper bus bar (4 wide by 1/2 thick)?! (a) 500 amps! (c) 1500 amps! (b) 1000 amps! (d) 2000 amps 84.!Sheet metal auxiliary gutters shall be supported throughout their entire length at intervals not! exceeding feet.! (a) 5! (b) 6! (c) 8! (d) !In auxiliary gutters where the voltage on bus bars is 150 volts and the bars are opposite polarity,! held free in the air, the minimum spacing between the parts is inches.! (a) 3/4! (c) 1-1/2! (b) 1! (d) 2 Article 368: Busways 86.!For industrial use omission of overcurrent protection shall be permitted at points where busways! are reduced in size, provided that the smaller busway doesn t extend more than feet.! (a) 10! (b) 20! (c) 50! (d) !Where devices containing a disconnecting means are mounted out of reach, suitable means shall! be provided to operate the disconnecting means from the floor. Which of the following is! permitted?! (a) Devices cannot be mounted out of reach.! (c) Ropes, chains or sticks shall be provided! (b) Ladders are not permitted.!! (d) No method is permitted. 88.!Busways shall be securely supported, unless otherwise designed and marked at intervals not to! exceed feet.! (a) 3! (c) 8! (b) 5! (d) !Metal-enclosed busways, over 600 volts, shall be installed so that from induced circulating! currents in any adjacent metallic parts will not be hazardous to personnel or constitute a fire! hazard.! (a) stray currents! (c) the impedance! (b) magnetic flux! (d) temperature rise

13 90.!Busways over 600 volts having sections located both inside and outside of buildings shall have a! at the building wall.!!! (a) vapor seal! (c) condulet! (b) fire barrier! (d) ventilated enclosure 91.!Busways rated over 600 volts shall have all conductor termination and connection hardware! accessible for.! (a) installation! (c) maintenance! (b) connection! (d) all of these

WIRING METHODS CHAPTER 38

WIRING METHODS CHAPTER 38 CHAPTER 38 WIRING METHODS SECTION E3801 GENERAL REQUIREMENTS E3801.1 Scope. This chapter covers the wiring methods for services, feeders and branch circuits for electrical power and distribution. E3801.2

More information

NEC 2014 Code Changes

NEC 2014 Code Changes NEC 2014 Code Changes Articles 280.21-300.50 CHANGES FROM 2011 TO 2014 CODE ARE IN RED Chapter 2 - Wiring and Protection ARTICLE 280 Surge Arresters, Over 1000 volts II. Instillation III. Connecting Surge

More information

Appendix C - International NEC Electric Code Amendments

Appendix C - International NEC Electric Code Amendments - International NEC Electric Code Amendments The International NEC Electric Code shall be amended as follows: (Revised Ord 2016-52) Section 220.14(A) Specific Appliances or Loads. At the end of this Sub-Section,

More information

Article 300: Wiring Methods And Materials

Article 300: Wiring Methods And Materials Part E: Code Book Questions Article 300: Wiring Methods And Materials 1.! Conductors of A.C. or D.C. circuits rated 600 volt or less, shall be permitted to occupy the same! conduit if.! (a)!conductors

More information

2003 International Residential Code ELECTRICAL PROVISIONS ONLY October 2005 EDITORIAL CHANGES SEVENTH PRINTING

2003 International Residential Code ELECTRICAL PROVISIONS ONLY October 2005 EDITORIAL CHANGES SEVENTH PRINTING 2003 International Residential Code ELECTRICAL PROVISIONS ONLY October 2005 EDITORIAL CHANGES SEVENTH PRINTING E3305.3: now reads The space equal to the width and depth of the panelboard and extending

More information

BASIC CONCEPTS IN ELECTRICAL DESIGN. Prepared by Engr. John Paul Timola

BASIC CONCEPTS IN ELECTRICAL DESIGN. Prepared by Engr. John Paul Timola BASIC CONCEPTS IN ELECTRICAL DESIGN Prepared by Engr. John Paul Timola ELECTRICAL CONDUCTORS AND INSULATORS Electrical Conductors substances that offer a very low resistance to current flow. Insulators

More information

Panel 7 Proposals For 2005 NEC Articles 320, 322, 324, 326, 328, 330, 332, 334, 336, 338, 340, 382, 394, 396 and 398

Panel 7 Proposals For 2005 NEC Articles 320, 322, 324, 326, 328, 330, 332, 334, 336, 338, 340, 382, 394, 396 and 398 Panel 7 Proposals For 2005 NEC Articles 320, 322, 324, 326, 328, 330, 332, 334, 336, 338, 340, 382, 394, 396 and 398 The National Electrical Code Technical Correlating Committee Identified concerns with

More information

EFFECTIVE DATE: November 1, 2011, unless a later date is cited at the end of a section. [ NMAC - Rp,

EFFECTIVE DATE: November 1, 2011, unless a later date is cited at the end of a section. [ NMAC - Rp, TITLE 14 CHAPTER 10 PART 4 HOUSING AND CONSTRUCTION ELECTRICAL CODES 2011 NEW MEXICO ELECTRICAL CODE 14.10.4.1 ISSUING AGENCY: The Construction Industries Division of the Regulation and Licensing Department.

More information

SERVICES CHAPTER 35. wire. For all other installations, the rating of the ungrounded conductors shall be not less than 60 amperes.

SERVICES CHAPTER 35. wire. For all other installations, the rating of the ungrounded conductors shall be not less than 60 amperes. CHAPTER 35 SERVICES SECTION E3501 GENERAL SERVICES E3501.1 Scope. This chapter covers service conductors and equipment for the control and protection of services and their installation requirements. E3501.2

More information

TABLE OF CONTENTS CHAPTER 2 WIRING AND PROTECTION CHAPTER 1 GENERAL RULES... 19

TABLE OF CONTENTS CHAPTER 2 WIRING AND PROTECTION CHAPTER 1 GENERAL RULES... 19 TABLE OF CONTENTS About This Textbook... xvii How to Use the National Electrical Code... 1 Article 90 Introduction to the National Electrical Code... 7 90.1 Purpose of the NEC... 7 90.2 Scope of the NEC...

More information

Student Services & Classroom Addition

Student Services & Classroom Addition SECTION 260533 - RACEWAY AND BOXES FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes raceways, fittings, boxes, enclosures, cabinets, and track busway for electrical wiring.

More information

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 26 ELECTRICAL SECTION RACEWAY AND BOXES FOR ELECTRICAL SYSTEMS

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 26 ELECTRICAL SECTION RACEWAY AND BOXES FOR ELECTRICAL SYSTEMS SECTION 260533 - RACEWAY AND BOXES FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 SUMMARY A. This Section includes raceways, fittings, boxes, enclosures, and cabinets for electrical wiring. B. See Division

More information

A. Product Data: For surface pathways, wireways and fittings, floor boxes, hinged-cover enclosures, and cabinets.

A. Product Data: For surface pathways, wireways and fittings, floor boxes, hinged-cover enclosures, and cabinets. ALLIANT ENERGY CENTER PAVILIONS Project No. 2013 027 SECTION 27 05 28 - PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions

More information

IMPORTANT CODE UPDATE ENFORCEMENT DATE FOR NEW NATIONAL ELECTRIC CODE IS SET FOR MAY 1, 2013

IMPORTANT CODE UPDATE ENFORCEMENT DATE FOR NEW NATIONAL ELECTRIC CODE IS SET FOR MAY 1, 2013 IMPORTANT CODE UPDATE ENFORCEMENT DATE FOR NEW NATIONAL ELECTRIC CODE IS SET FOR MAY 1, 2013 2011 National Electrical Code (NEC) Update Statement The National Electrical Code, 2011 Edition, with Appendices,

More information

DESIGN GUIDELINES WIRING AND CONDUITS PAGE 1 of 7

DESIGN GUIDELINES WIRING AND CONDUITS PAGE 1 of 7 DESIGN GUIDELINES WIRING AND CONDUITS PAGE 1 of 7 1.1. REFERENCE STANDARDS 1.1.1. Publications listed below (including amendments, addenda, revisions, supplements and errata) form a part of this specification

More information

Design Standard Conduit for Electrical Systems

Design Standard Conduit for Electrical Systems Design Standard Purpose: This design standard has the purpose of creating a consistent application for the installation of conduits throughout the East Side Union High School District, therefore achieving

More information

EFFECTIVE DATE: July 1, 2008, unless a later date is cited at the end of a section. [ NMAC - Rp,

EFFECTIVE DATE: July 1, 2008, unless a later date is cited at the end of a section. [ NMAC - Rp, TITLE 14 CHAPTER 10 PART 4 HOUSING AND CONSTRUCTION ELECTRICAL CODES 2008 NEW MEXICO ELECTRICAL CODE 14.10.4.1 ISSUING AGENCY: The Construction Industries Division of the Regulation and Licensing Department.

More information

Sections through of Chapter 5 of the Victoria City Code are amended to read as follows: ARTICLE IX. NATIONAL ELECTRICAL CODE

Sections through of Chapter 5 of the Victoria City Code are amended to read as follows: ARTICLE IX. NATIONAL ELECTRICAL CODE Sections 5-100 through 5-105 of Chapter 5 of the Victoria City Code are amended to read as follows: ARTICLE IX. NATIONAL ELECTRICAL CODE Sec. 5-100. Adoption of published code. There is hereby adopted

More information

Replace 210.8(a)(7) with: Sinks. Where receptacles are installed within 6 feet of the outside edge of a sink. Page 1 of 5

Replace 210.8(a)(7) with: Sinks. Where receptacles are installed within 6 feet of the outside edge of a sink. Page 1 of 5 CHAPTER 23.30 LOCAL AMENDMENTS TO THE NATIONAL ELECTRICAL CODE 2002 EDITION SECTIONS: 23.30.010 Local Amendments to the National Electrical Code 2002 Edition 23.30.020 Certificate of Fitness - Right to

More information

DIVISION 26 RACEWAYS AND BOXES FOR ELECTRICAL SYSTEMS PART 1 - GENERAL RELATED DOCUMENTS

DIVISION 26 RACEWAYS AND BOXES FOR ELECTRICAL SYSTEMS PART 1 - GENERAL RELATED DOCUMENTS PART 1 - GENERAL 01.01 RELATED DOCUMENTS A. Drawings and general provisions of Contract, including General and Supplementary Conditions and Division 1 Specification sections, apply to work of this Section.

More information

CITY OF OCEANSIDE. Electrical Lines, Plumbing and Mechanical Burial & Support Requirements. Informational Bulletin

CITY OF OCEANSIDE. Electrical Lines, Plumbing and Mechanical Burial & Support Requirements. Informational Bulletin Electrical Lines, Plumbing and Mechanical Burial & Support Requirements Informational Bulletin MINIMUM BURIAL DEPTH REQUIREMENTS 2016 CALIFORNIA ELECTRICAL CODE (CEC) Burial depth shall be per Table 300.5,

More information

About This Textbook... xvii About the National Electrical Code...xxi About the Author... xxv About the Illustrator... xxvi About the Team...

About This Textbook... xvii About the National Electrical Code...xxi About the Author... xxv About the Illustrator... xxvi About the Team... About This Textbook... xvii About the National Electrical Code...xxi About the Author... xxv About the Illustrator... xxvi About the Team...xxvii Article 90 Introduction to the National Electrical Code...

More information

SECTION WIRE, CABLE AND BUSWAYS. A. This section specifies providing wire, cable and busways.

SECTION WIRE, CABLE AND BUSWAYS. A. This section specifies providing wire, cable and busways. SECTION 16120 WIRE, CABLE AND BUSWAYS PART 1 - GENERAL 1.01 DESCRIPTION: A. This section specifies providing wire, cable and busways. B. Definitions: 1. Cable: Cable having low smoke generating characteristics.

More information

Procurement Services SVC East Fowler Avenue Tampa, Florida (813)

Procurement Services SVC East Fowler Avenue Tampa, Florida (813) Procurement Services SVC 1073 4202 East Fowler Avenue Tampa, Florida 33620 (813) 974-2481 Web Address: https://www.usf.edu/business-finance/purchasing/public-bids/rfi.aspx October 12, 2018 Invitation to

More information

SECTION PATHWAYS FOR ELECTRONIC SAFETY AND SECURITY

SECTION PATHWAYS FOR ELECTRONIC SAFETY AND SECURITY SECTION 280528 - PATHWAYS FOR ELECTRONIC SAFETY AND SECURITY PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Metal conduits, tubing, and fittings. 2. Nonmetallic conduits, tubing, and fittings. 3.

More information

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 5/12/10 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 5/12/10 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions MECKLENBURG COUNTY Land Use and Environmental Service Agency Code Enforcement 5/12/10 ELECTRICAL CONSISTENCY MEETING Code Consistency Questions 1. Is it illegal to install a wet-niche luminaire face-up

More information

SECTION GROUNDING

SECTION GROUNDING SECTION 16450 GROUNDING PART 1 - GENERAL 1.1 DESCRIPTION A. This section specifies general grounding and bonding requirements of electrical and telecommunication installations for personnel safety, equipment

More information

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: Electrical Standards

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: Electrical Standards Date Description of Change Pages / Sections Modified ID 6/15/16 Updated format, division title, and removed references to other sections. - mgl44 A. Summary This section contains design criteria for the

More information

2008 NEC Guide Lines for Home Owner Doing Electrical Work on their Property

2008 NEC Guide Lines for Home Owner Doing Electrical Work on their Property 2008 NEC Guide Lines for Home Owner Doing Electrical Work on their Property A brief summary of the most used code references for residential wiring State of Idaho Division of Building Safety Electrical

More information

CONTENTS. B. System Design and Performance Requirements

CONTENTS. B. System Design and Performance Requirements 16060 Grounding and Bonding This document provides design standards only, and is not intended for use, in whole or in part, as a specification. Do not copy this information verbatim in specifications or

More information

B. Provide a complete conduit system with associated couplings, connectors, and fittings.

B. Provide a complete conduit system with associated couplings, connectors, and fittings. SECTION 26 05 33 PART 1 - GENERAL 1.01 WORK INCLUDED A. Comply with the provisions of Sections 260500. B. Provide a complete conduit system with associated couplings, connectors, and fittings. 1.02 RELATED

More information

Standard of Practice - Campus Electrical Distribution System

Standard of Practice - Campus Electrical Distribution System A26.3 Standard of Practice - Campus Electrical Distribution System NOTE: Significant revisions or additions to the previous standards are highlighted in italics. GENERAL Designers shall verify that all

More information

(Condensed from National Electric Code)

(Condensed from National Electric Code) WIRING, SPECIFICATIONS, INSPECTION, AND METER INSTALLATION PROCEDURES FOR RESIDENTIAL CUSTOMERS SERVED BY SOUTHWEST ARKANSAS ELECTRIC COOPERATIVE CORPORATION Effective April 1, 1974 Revised February 3,

More information

CHAPTER LOCAL AMENDMENTS TO THE NATIONAL ELECTRICAL CODE 2011 EDITION

CHAPTER LOCAL AMENDMENTS TO THE NATIONAL ELECTRICAL CODE 2011 EDITION CHAPTER 23.30 LOCAL AMENDMENTS TO THE NATIONAL ELECTRICAL CODE 2011 EDITION Sections 23.30.010 Local amendments to the National Electrical Code 2011 Edition.... 1 23.30.020 Certificate of fitness - right

More information

6. SECONDARY SERVICES (under 600 volts) 6.1 AVAILABILITY For the electrical characteristics of available secondary services see Section 3.4.

6. SECONDARY SERVICES (under 600 volts) 6.1 AVAILABILITY For the electrical characteristics of available secondary services see Section 3.4. 6. SECONDARY SERVICES (under 600 volts) 6.1 AVAILABILITY For the electrical characteristics of available secondary services see Section 3.4. 6.2 OVERHEAD SERVICES Wiring of any premises for connection

More information

Inspection Guide for PV Systems in One- and Two- Family Dwellings (For Rooftop Photovoltaic Systems meeting the Standard Plan)

Inspection Guide for PV Systems in One- and Two- Family Dwellings (For Rooftop Photovoltaic Systems meeting the Standard Plan) TOOLKIT DOCUMENT #7 Inspection Guide for PV Systems in One- and Two- Family Dwellings (For Rooftop Photovoltaic Systems meeting the Standard Plan) This document has two sections. Neither section is all-inclusive

More information

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 7/14/10 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 7/14/10 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions MECKLENBURG COUNTY Land Use and Environmental Service Agency Code Enforcement 7/14/10 ELECTRICAL CONSISTENCY MEETING Code Consistency Questions 1. We were turned down for an underground installation of

More information

Specifications Rigid Metal Conduit / PVC Coated Rigid Metal Conduit

Specifications Rigid Metal Conduit / PVC Coated Rigid Metal Conduit Specifications Rigid Metal Conduit / PVC Coated Rigid Metal Conduit Ref. CEC Rule 12-1000 Rigid Metal Conduit affords maximum mechanical protection to conductors within the raceway. Rigid metal conduit

More information

MANUFACTURING TECHNICAL INSTRUCTIONS SAFETY Subject: DESIGN, MAINTENANCE AND INSPECTION OF SECONDARY ELECTRICAL DISTRIBUTION SYSTEMS

MANUFACTURING TECHNICAL INSTRUCTIONS SAFETY Subject: DESIGN, MAINTENANCE AND INSPECTION OF SECONDARY ELECTRICAL DISTRIBUTION SYSTEMS DAIMLERCHRYSLER MANUFACTURING TECHNICAL INSTRUCTIONS SAFETY Subject: DESIGN, MAINTENANCE AND INSPECTION OF SECONDARY ELECTRICAL DISTRIBUTION SYSTEMS ISSUE DATE: 5/1/90 EFFECTIVE DATE: 2/4/92 REVIEW DATE:

More information

DEVICES AND LUMINAIRES

DEVICES AND LUMINAIRES CHAPTER 40 DEVICES AND LUMINAIRES SECTION E4001 SWITCHES E4001.1 Rating and application of snap switches. General-use snap switches shall be used within their ratings and shall control only the following

More information

Click here to get back to 2011 NEC Code Updates Part 1

Click here to get back to 2011 NEC Code Updates Part 1 www.garyklinka.com Page 1 of 13 2011 NEC Code Updates Code Language Part 1 Click here to get back to 2011 NEC Code Updates Part 1 100 Definitions Ampacity. The maximum current, in amperes, that a conductor

More information

UNDERGROUND SERVICES SECONDARY

UNDERGROUND SERVICES SECONDARY Reference UNDERGROUND SERVICES SECONDARY Underground services secondary... U- 1 General requirements for underground service... U- 2 Name of parts for underground service... U- 3 Conduit layouts... U-

More information

MREC March, 2005 Powering the Dairy Industry

MREC March, 2005 Powering the Dairy Industry Mark A. Cook Manager Licensed Designer of Engineering Systems Certified Commercial and UDC Electrical Inspector Certified Master Electrician Public Service Commission of Wisconsin mark.cook@starband.net

More information

3. Intermediate metal conduit (IMC). 4. Electric metallic tubing (EMT). 5. Flexible metal conduit (FLEX). 6. Polyvinyl chloride conduit (PVC).

3. Intermediate metal conduit (IMC). 4. Electric metallic tubing (EMT). 5. Flexible metal conduit (FLEX). 6. Polyvinyl chloride conduit (PVC). SECTION 16111 CONDUITS PART 1 - GENERAL 1.01 DESCRIPTION A. General: Provide conduits, complete, as shown, specified or required per Contract Documents. Principal items include: 1. Rigid aluminum conduit.

More information

Specifications Electrical Metallic Tubing (EMT)

Specifications Electrical Metallic Tubing (EMT) T& Fittings Specifications Electrical Metallic Tubing (EMT) Ref. CEC Rule 12-000 not exceeding 750 Volts Electrical Metallic Tubing (EMT) is similar to rigid steel conduit but is much lighter, weighing

More information

T&B Fittings. Industrial Fittings. Rigid Metal Conduit Fittings. Specifications Rigid Metal Conduit/PVC Coated Rigid Metal Conduit

T&B Fittings. Industrial Fittings. Rigid Metal Conduit Fittings. Specifications Rigid Metal Conduit/PVC Coated Rigid Metal Conduit Specifications Rigid Metal Conduit/PVC Coated Rigid Metal Conduit Ref. CEC Rule 12-1000 Rigid Metal Conduit affords maximum mechanical protection to conductors within the raceway. Rigid metal conduit can

More information

6. SECONDARY SERVICES (under 600 volts) 6.1 AVAILABILITY For the electrical characteristics of available secondary services see Section 3.4.

6. SECONDARY SERVICES (under 600 volts) 6.1 AVAILABILITY For the electrical characteristics of available secondary services see Section 3.4. 6. SECONDARY SERVICES (under 600 volts) 6.1 AVAILABILITY For the electrical characteristics of available secondary services see Section 3.4. 6.2 OVERHEAD SERVICES Wiring of any premises for connection

More information

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number: SECTION 260526 - GROUNDING AND BONDING FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract apply to this Section. 1.2 SUMMARY A. This Section

More information

GLENWOOD PLACE 2 MAR 2015

GLENWOOD PLACE 2 MAR 2015 PART 1 - GENERAL 1.01 SUMMARY: SECTION 16110 RACEWAYS A. Description: 1. Provide continuous conduit systems - beginning at the service point, to all distribution equipment and to every outlet and piece

More information

1.2 REFERENCES.1 CSA C22.2 No.0.3, Test Methods for Electrical Wires and Cables.

1.2 REFERENCES.1 CSA C22.2 No.0.3, Test Methods for Electrical Wires and Cables. Issued 2005/06/01 Section 16122 Wire and Cables (0 1000V) Page 1 of 5 PART 1 GENERAL 1.1 RELATED SECTIONS.1 Section 16151 Wire and Box Connectors 0 1000 1.2 REFERENCES.1 CSA C22.2 No.0.3, Test Methods

More information

Youngstown State University

Youngstown State University SECTION 260533 - RACEWAYS PART 1 - GENERAL SUMMARY A. This section includes raceways for electrical wiring. Types of raceways in this section include the following: 1. Flexible metal conduit 2. Liquid

More information

CHAPTER 11 CONDUITS AND FITTINGS

CHAPTER 11 CONDUITS AND FITTINGS CONDUITS AND FITTINGS CHAPTER 11 CONDUITS AND FITTINGS The standards and requirements for conduits and fittings used for traffic control signal and lighting systems are presented in this chapter. 11.1

More information

A. All materials shall be tested and listed by an OSHA approved Nationally Recognized Testing Laboratory (NRTL).

A. All materials shall be tested and listed by an OSHA approved Nationally Recognized Testing Laboratory (NRTL). 16450 GROUNDING ************************************************************************************************************* SPECIFIER: CSI MasterFormat 2004 number: 26 05 26 An optional keynote to the

More information

SECTION CONDUIT AND FITTINGS

SECTION CONDUIT AND FITTINGS SECTION 16111 CONDUIT AND FITTINGS PART 1 - GENERAL 1.1 DESCRIPTION A. This section describes specific requirements, products, and methods of execution relating to conduit and conduit fittings approved

More information

CONDUITS AND FITTINGS

CONDUITS AND FITTINGS CONDUIT AND FITTINGS Rigid Steel Conduit 3801 Rigid PVC Conduit 3803 HDPE Conduit 3803 Flexible Non Metallic Liquid Tight Conduit Type LFNC-B 3804 PVC Coated Urethane Lined Galvanized Rigid Steel Conduit

More information

DEVICES AND LUMINAIRES

DEVICES AND LUMINAIRES CHAPTER 39 DEVICES AND LUMINAIRES SECTION E3901 SWITCHES E3901.1 Rating and application of snap switches [404.14(A)]. General-use snap switches shall be used within their ratings and shall control only

More information

Please check with your local inspection authority for any additional requirements before installation.

Please check with your local inspection authority for any additional requirements before installation. Specifications for Residential Underground Electric Service Installation This brochure addresses most typical residential underground service installations. Variances for the following specifications must

More information

UNDERGROUND SERVICES (RESIDENTIAL) SINGLE FAMILY RESIDENTIAL, DUPLEXES, OR TOWNHOUSES

UNDERGROUND SERVICES (RESIDENTIAL) SINGLE FAMILY RESIDENTIAL, DUPLEXES, OR TOWNHOUSES 7.01 GENERAL UNDERGROUND SERVICES (RESIDENTIAL) SINGLE FAMILY RESIDENTIAL, DUPLEXES, OR TOWNHOUSES Also refer to Chapter 3 (Service Entrances), and Chapter 4 (Metering Installation). OPPD will install,

More information

SECTION (Master Template Final-05) ELECTRICAL BOXES. A. Provide boxes for electrical equipment and wiring devices as follows:

SECTION (Master Template Final-05) ELECTRICAL BOXES. A. Provide boxes for electrical equipment and wiring devices as follows: SECTION 16130 (Master Template Final-05) ELECTRICAL BOXES PART 1 GENERAL 1.01 SECTION INCLUDES A. Provide boxes for electrical equipment and wiring devices as follows: 1. Wall and ceiling outlet boxes.

More information

SECTION PART 1 GENERAL

SECTION PART 1 GENERAL SECTION 16060 GROUNDING AND BONDING PART 1 GENERAL 1.1 SUMMARY A. Section Includes: Grounding of electrical systems and equipment and basic requirements for ground for equipment, circuits, and systems.

More information

BASIC ELECTRICAL MATERIALS AND METHODS

BASIC ELECTRICAL MATERIALS AND METHODS BASIC ELECTRICAL MATERIALS AND METHODS General Scope Provide raceways for all wiring. All exposed and concealed wiring (including low voltage control, telecommunications, and power limited wiring) shall

More information

ELECTRICAL DEFINITIONS

ELECTRICAL DEFINITIONS CHAPTER 35 ELECTRICAL DEFINITIONS SECTION E3501 GENERAL E3501.1 Scope. This chapter contains definitions that shall apply only to the electrical requirements of Chapters 34 through 43. Unless otherwise

More information

METERING INSTALLATION

METERING INSTALLATION 4.01 METERING SPECIFICATIONS METERING INSTALLATION Metering specifications will be issued to the customer by OPPD. Metering specifications are required before any work is started on all new wiring or additions

More information

ELECTRICAL SAFETY Information Bulletin

ELECTRICAL SAFETY Information Bulletin ELECTRICAL SAFETY Information Bulletin March 2014 CEC-12 [rev-6] Page 1 of 6 CANADIAN ELECTRICAL CODE SUBJECT: Section 12 Wiring Methods Conductors General Insulation Thickness on Conductors Used in Ungrounded

More information

SECTION PATHWAYS FOR COMMUNICATIONS SYSTEMS

SECTION PATHWAYS FOR COMMUNICATIONS SYSTEMS SECTION 270528 PATHWAYS FOR COMMUNICATIONS SYSTEMS PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Communications equipment coordination and installation. 2. Sleeves for pathways and cables. 3. Raceway

More information

POWER AND LIGHTING DISTRIBUTION Reserved

POWER AND LIGHTING DISTRIBUTION Reserved CHAPTER POWER AND LIGHTING DISTRIBUTION Reserved INTERNATIONAL RESIDENTIAL CODE R This page left intentionally blank. R INTERNATIONAL RESIDENTIAL CODE SECTION E GROUND-FAULT AND ARC-FAULT CIRCUIT-INTERRUPTER

More information

a) Line and load compartments must be separated by a stable barrier.

a) Line and load compartments must be separated by a stable barrier. 1.00 GENERAL 1.01 The electric utility shall furnish and connect all meters, instrument transformers, test switches, and meter control wiring necessary to complete the meter installation. 1.02 The customer

More information

City of Santa Monica Building and Safety Division

City of Santa Monica Building and Safety Division This is to be used as a general checklist; it is not inclusive of all code requirements and inspection criteria. General requirements Verify that address on permit matched Address, Description and Approvals:

More information

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 11/10/10 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 11/10/10 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions MECKLENBURG COUNTY Land Use and Environmental Service Agency Code Enforcement 11/10/10 ELECTRICAL CONSISTENCY MEETING Code Consistency Questions 1. If a microwave oven, or refrigerator or freezer has a

More information

ELECTRICAL SECTION 2

ELECTRICAL SECTION 2 ELECTRICAL SECTION 2 COMMON WORK RESULTS FOR ELECTRICAL PART 1 - GENERAL 1.1 GENERAL REQUIREMENTS A. This Section includes raceways, conductors and cables, grounding materials, boxes, electrical identification

More information

1.05 Power System Fault and Coordination Study with Arc Flash Calculations

1.05 Power System Fault and Coordination Study with Arc Flash Calculations PART 1: GENERAL 1.01 Underground Ducts and Manholes A. The work included in this section of the construction standards consists of the design requirements for the complete layout and installation of a

More information

DOWNTOWN UNDERGROUND NETWORK SECONDARY SERVICES GUIDELINES

DOWNTOWN UNDERGROUND NETWORK SECONDARY SERVICES GUIDELINES Guidelines effective March 5, 2007 NES is committed to providing safe, reliable electric service at a reasonable price for all of our customers. These guidelines offer direction for activities relating

More information

POWER AND LIGHTING DISTRIBUTION

POWER AND LIGHTING DISTRIBUTION CHAPTER POWER AND LIGHTING DISTRIBUTION Chapter is not adopted in the City of Seattle. See the Seattle Electrical Code for electrical regulations. SECTION E RECEPTACLE OUTLETS E. General. Outlets for receptacles

More information

A. Provide a complete Distribution Panelboard system as indicated on the drawings, and as specified herein.

A. Provide a complete Distribution Panelboard system as indicated on the drawings, and as specified herein. 16470 PANELBOARDS ************************************************************************************************************* SPECIFIER: CSI MasterFormat 2004 number: 26 24 16 An optional keynote to

More information

2008 Port of San Francisco Electrical Code February 2010 edition. February 2010 edition of the 2008 Port of San Francisco Building Code

2008 Port of San Francisco Electrical Code February 2010 edition. February 2010 edition of the 2008 Port of San Francisco Building Code of the 2008 Port of San Francisco Building Code The complete of the 2008 Port of San Francisco Building Code includes the of the 2008 Port of San Francisco Electrical Code, which adopts and amends, the

More information

SECTION METAL-ENCLOSED BUS MEDIUM VOLTAGE

SECTION METAL-ENCLOSED BUS MEDIUM VOLTAGE METAL-ENCLOSED BUS MEDIUM VOLTAGE PART 1 GENERAL 1.01 1.02 1.03 1.04 1.05 SCOPE The Contractor shall furnish and install the equipment as specified herein and as shown on the contract drawings. The medium

More information

1510 RACEWAY AND BOXES FOR ELECTRICAL SYSTEMS

1510 RACEWAY AND BOXES FOR ELECTRICAL SYSTEMS SECTION 260533-RACEWAY AND BOXES FOR ELECTRICAL SYSTEMS PART 1 GENERAL 1.1 SUMMARY A. Section includes conduit raceways, and tubing, surface raceways, wireways, outlet boxes, pull and junction boxes, and

More information

OVERHEAD SERVICES - SECONDARY

OVERHEAD SERVICES - SECONDARY OVERHEAD SERVICES - SECONDARY Contents - Overhead Services... O-1 General Requirements for Overhead Service... O-2 Names of Parts for Overhead Service... O-3 Service Attachment on an Unguyed Service Mast...

More information

B. Insulated Conductors: Stranded copper wire, green or green with yellow stripe insulation, insulated for 600 V, and complying with UL 83.

B. Insulated Conductors: Stranded copper wire, green or green with yellow stripe insulation, insulated for 600 V, and complying with UL 83. SECTION 270526 - GROUNDING AND BONDING FOR COMMUNICATIONS SYSTEMS PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Grounding conductors. 2. Grounding connectors. 3. Grounding busbars. 4. Grounding

More information

SECTION CONDUI T

SECTION CONDUI T PART1 GENERA L 1.01 SECTION INCLUDE S SECTION 26 0534 CONDUI T A. Galvanized steel rigid metal conduit (RMC). B. Intermediate metal conduit (IMC). C. Flexible metal conduit (FMC). D. Liquidtight flexible

More information

SECTION CONDUITS AND BACKBOXES FOR COMMUNICATIONS SYSTEMS

SECTION CONDUITS AND BACKBOXES FOR COMMUNICATIONS SYSTEMS SECTION 16711-27 05 28.33 PART 1 - GENERAL 1.01 SUMMARY A. This section includes Labor, materials and equipment necessary to complete the installation required for the items specified under this Section,

More information

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017 SECTION 26 0526 - GROUNDING AND BONDING FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions

More information

Raceway and Boxes for Electrical Systems Page 1 of 7

Raceway and Boxes for Electrical Systems Page 1 of 7 Last Update: May 12, 2017 A. Conduits: Page 1 of 7 1. All conductors for each and every electrical system shall be installed in a raceway except communications and A/V systems which shall have stubs to

More information

SECTION A. Underwriters Laboratories, Inc., listed and NEC approved

SECTION A. Underwriters Laboratories, Inc., listed and NEC approved PART 1 GENERAL 1.01 DESCRIPTION A. Provide all raceways, fittings, and boxes of specified type required for complete project. Install all systems in raceways unless specifically noted otherwise. Provide

More information

2. Article (A) Delete the measurement of 6 feet 7 inches and insert: 66 inches (5 feet 6 inches).

2. Article (A) Delete the measurement of 6 feet 7 inches and insert: 66 inches (5 feet 6 inches). H. The National Electric Code 2011 is hereby revised: 1. Article 230.70 (A) (1) Delete in its entirety and insert: 230.70 (A) (1) Readily Accessible Location. The service disconnect means shall be installed

More information

SECTION OUTLET, PULL, AND JUNCTION BOXES

SECTION OUTLET, PULL, AND JUNCTION BOXES SECTION 16131 OUTLET, PULL, AND JUNCTION BOXES PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. 09900 - Painting. 2. 16112 - Raceways and Conduits. 1.02 SYSTEM DESCRIPTION A. Performance Requirements:

More information

A. This section includes building wire and cable rated 600V and less Full Short Circuit Device, Coordination and Arc Fault Study

A. This section includes building wire and cable rated 600V and less Full Short Circuit Device, Coordination and Arc Fault Study PART 1: GENERAL 1.01 Underground Ducts and Manholes A. The work included in this section of the construction standards consists of the design requirements for the complete layout and installation of a

More information

This product specification is written according to the Construction Specifications Institute MasterFormat, 2014 Update.

This product specification is written according to the Construction Specifications Institute MasterFormat, 2014 Update. Kaf-Tech Product Specification This product specification is written according to the Construction Specifications Institute MasterFormat, 2014 Update. SECTION 260519 METAL CLAD CABLE - MC-PLUS Neutral

More information

Code Compliance for Spring Steel Fasteners Based on the 2005 NEC

Code Compliance for Spring Steel Fasteners Based on the 2005 NEC Code Compliance for Spring Steel Fasteners Based on the 2005 NEC B-Line has recognized the need for a reference source, detailing the National Electrical Code requirements for Spring Steel Fasteners. The

More information

NORTHEASTERN REMC ELECTRIC STANDARDS MANUAL

NORTHEASTERN REMC ELECTRIC STANDARDS MANUAL NORTHEASTERN REMC ELECTRIC STANDARDS MANUAL WARNING Before digging or trenching... Call 811 Indiana Underground Protection Service 1-800-382-5544 AVOID BURIED POWER CABLES 4901 East Park 30 Drive P.O.

More information

SECTION CONDUIT AND BOXES

SECTION CONDUIT AND BOXES PART 1 - GENERAL 1.01 SUMMARY SECTION 27 05 33 CONDUIT AND BOXES A. This Section includes specific requirements for conduits and boxes within the Communications Pathway System as defined in Division 27

More information

SECTION ELECTRICAL UTILITY SERVICES

SECTION ELECTRICAL UTILITY SERVICES SECTION 33 71 73 ELECTRICAL UTILITY SERVICES PART 1 GENERAL 1.1 REFERENCES A. American Association of State Highway Officials (AASHO): 1. Standard Specifications B. California Administrative Code (CAC):

More information

Service Entrance Cable Fittings

Service Entrance Cable Fittings Suggested Specifications for Service Entrance Fittings All service fittings shall be approved for the purpose by a nationally recognized testing laboratory, inspection agency or product evaluation organization.

More information

SECTION WIRE AND CABLE Raceways and Conduit Motor Power and Control Wiring.

SECTION WIRE AND CABLE Raceways and Conduit Motor Power and Control Wiring. SECTION 16120 WIRE AND CABLE PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. 16112 - Raceways and Conduit. 2. 16155 - Motor Power and Control Wiring. 1.02 SYSTEM DESCRIPTION A. Performance Requirements:

More information

SECTION GROUNDING AND BONDING

SECTION GROUNDING AND BONDING SECTION 16060 GROUNDING AND BONDING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification

More information

POWER AND LIGHTING DISTRIBUTION

POWER AND LIGHTING DISTRIBUTION CHAPTER POWER AND LIGHTING DISTRIBUTION SECTION E RECEPTACLE OUTLETS E. General [.,.]. Outlets for receptacles rated at volts, - and -amperes shall be provided in accordance with Sections E. through E..

More information

Educational Course Application

Educational Course Application STATE OF WISCONSIN Department of Safety and Professional Services Educational Course Application Personal information you provide may be used for secondary purposes [Privacy Law, s. 15.04(1)(m)]. Division

More information

WIRE AND CABLE Raceways and Conduit Motor Power and Control Wiring.

WIRE AND CABLE Raceways and Conduit Motor Power and Control Wiring. SECTION 16120 WIRE AND CABLE PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. 16112 - Raceways and Conduit. 2. 16155 - Motor Power and Control Wiring. 1.02 SYSTEM DESCRIPTION A. Performance Requirements:

More information

A. Coordinate arrangement, mounting, and support of electrical equipment:

A. Coordinate arrangement, mounting, and support of electrical equipment: SECTION 260500 -BASIC ELECTRICAL MATERIALS AND METHODS PART 1- GENERAL 1.1 SUMMARY A. This Section includes the following: 1. Electrical equipment coordination and installation. 2. Sleeves for raceways

More information

ORDINANCE NO. ORD

ORDINANCE NO. ORD ORDINANCE NO. ORD-2012-9407 AN ORDINANCE AMENDING SECTION 8-11 OF ARTICLE II BUILDING CODES OF CHAPTER 8 IRVING BUILDING STANDARDS CODE OF THE IRVING LAND DEVELOPMENT CODE BY ADOPTING THE 2011 EDITION

More information