CODE REQUIREMENTS: CONFORM TO THE 2014 OREGON STRUCTURAL SPECIALTY CODE (OSSC), BASED ON THE 2012 INTERNATIONAL BUILDING CODE (IBC).

Size: px
Start display at page:

Download "CODE REQUIREMENTS: CONFORM TO THE 2014 OREGON STRUCTURAL SPECIALTY CODE (OSSC), BASED ON THE 2012 INTERNATIONAL BUILDING CODE (IBC)."

Transcription

1 DRAWING INDE S0. GENERAL STRUCTURAL NOTES S0. GENERAL STRUCTURAL NOTES (CONT.) S0. SPECIAL S S0. SPECIAL S (CONT.) S. OVERALL FRAMING PLAN - BUILDINGS A AND B S. PARTIAL FRAMING PLAN - BUILDING B DECK & STAIR S6. DETAILS SPACER ########## STRUCTURAL DRAWINGS ARE A PORTION OF THE CONTRACT DOCUMENTS AND ARE INTENDED TO BE USED WITH ARCHITECTURAL, MECHANICAL, AND ELECTRICAL DRAWINGS. THE CONTRACTOR IS RESPONSIBLE FOR COORDINATING THE FROM THESE DRAWINGS INTO THEIR SHOP DRAWINGS AND WORK. THESE GENERAL NOTES SUPPLEMENT THE PROJECT SPECIFICATIONS. REFER TO THE PROJECT SPECIFICATIONS FOR ADDITIONAL. NOTES AND DETAILS ON THE STRUCTURAL DRAWINGS SHALL TAKE PRECEDENCE OVER THE GENERAL NOTES AND TYPICAL DETAILS. WHERE NO DETAILS ARE GIVEN, CONSTRUCTION SHALL BE AS SHOWN FOR SIMILAR WORK. CODE : CONFORM TO THE 0 OREGON STRUCTURAL SPECIALTY CODE (OSSC), BASED ON THE 0 INTERNATIONAL BUILDING CODE (IBC). TEMPORARY CONDITIONS: THE STRUCTURE IS DESIGNED TO FUNCTION AS A UNIT UPON COMPLETION. THE CONTRACTOR IS RESPONSIBLE FOR FURNISHING ALL TEMPORARY BRACING AND/OR SUPPORT THAT MAY BE REQUIRED AS THE RESULT OF THE CONTRACTOR'S CONSTRUCTION METHODS AND/OR SEQUENCES. GENERAL STRUCTURAL NOTES SEISMIC LOAD RESISTING SYSTEM: THE SEISMIC LOAD RESISTING SYSTEM (SLRS) FOR THE COMPLETED STRUCTURE IS AS FOLLOWS: ELEVATED DECKS: STEEL MOMENT FRAME AT PERIMETER OF NEW DECK WITH PLYWOOD SHEATHED DIAPHRAGM DESIGN AND DETAILING WAS BASED ON CRITERIA FOR SEISMIC DESIGN CATEGORY D STRUCTURAL OBSERVATION: THE STRUCTURAL ENGINEER OF RECORD (SER) WILL PERFORM STRUCTURAL OBSERVATION BASED ON THE OF THE OSSC AT THE STAGES OF CONSTRUCTION LISTED BELOW. CONTRACTOR SHALL PROVIDE SUFFICIENT NOTICE AND ACCESS FOR THE SER TO PERFORM THESE OBSERVATIONS. ITEM STRUCTURAL OBSERVATIONS OBSERVED BY () PRIOR TO FIRST CONCRETE POUR REF. NOTES,,,5 AOR SER COMMENTS SW Fifth Ave., Suite 500 Portland, OR 970 O: CONTRACTOR'S CONSTRUCTION AND/OR ERECTION SEQUENCES SHALL RECOGNIZE AND CONSIDER THE EFFECTS OF THERMAL MOVEMENTS OF STRUCTURAL ELEMENTS DURING THE CONSTRUCTION PERIOD. DURING INITIAL STEEL ERECTION REF. NOTES,, AS REQUIRED TO ADDRESS STRUCTURAL ISSUES REF. NOTES,, EISTING CONDITIONS: ALL EISTING CONDITIONS, DIMENSIONS AND ELEVATIONS SHALL BE FIELD VERIFIED. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT OF ANY SIGNIFICANT DISCREPANCIES FROM CONDITIONS SHOWN ON THE DRAWINGS. ASSUMED FUTURE CONSTRUCTION: VERTICAL: NONE HORIZONTAL: NONE FOOTNOTES:. CONTRACTOR IS RESPONSIBLE FOR NOTIFYING THE SER IN ADVANCE.. SER - STRUCTURAL ENGINEER OF RECORD. AOR - ARCHITECT OF RECORD.. A FIELD REPORT WILL BE SUBMITTED TO THE BUILDING DEPARTMENT FOLLOWING EACH SITE VISIT. EPIRES DESIGN CRITERIA: DESIGN WAS BASED ON THE STRENGTH AND DEFLECTION CRITERIA OF THE OSSC. IN ADDITION TO THE DEAD LOADS, THE FOLLOWING LOADS AND ALLOWABLES WERE USED FOR DESIGN, WITH LIVE LOADS (L.L.) REDUCED PER OSSC: OFFICES ROOF LIVE/SNOW LOAD DESIGN CRITERIA GRAVITY SYSTEM CRITERIA 5 PSF L.L. (ALSO SEE SNOW LOAD CRITERIA BELOW) FLOOR LIVE LOADS: UNIFORM LOAD CONCENTRATED LOAD 50 PSF L.L. + 5 PSF FOR PARTITIONS, OR 00 PSF L.L. (INCLUDING PARTITIONS) WHICHEVER IS MORE CRITICAL FOR MEMBER DESIGN,000 LBS. STAIRWAYS 00 PSF L.L.,000 LBS. (00 STAIRS) RESIDENTIAL 0 PSF L.L. -. STRUCTURAL OBSERVATION IS FOR THE GENERAL CONFORMANCE OF THE STRUCTURAL DRAWING, SPECIAL IS STILL REQUIRED. 5. AFTER REINFORCING STEEL HAS BEEN INSTALLED. SPECIAL AND TESTING: SPECIAL WILL BE PROVIDED BY THE OWNER BASED ON THE OF THE OSSC AS SUMMARIZED IN THE SPECIAL AND TESTING PROGRAM ON SHEET S00. CONTRACTOR SHALL PROVIDE SUFFICIENT NOTICE AND ACCESS FOR THE SPECIAL INSPECTOR TO PERFORM THESE S. SUBMITTALS: SHOP DRAWINGS SHALL BE SUBMITTED TO THE ARCHITECT PRIOR TO FABRICATION AND CONSTRUCTION OF ALL STRUCTURAL ITEMS, INCLUDING THE FOLLOWING: ITEM SUBMITTALS SUBMITTAL (,) DEFERRED SUBMITTAL (,) COMMENTS VERTICAL FLOOR DEFLECTION 0.75" OR L/60 WHICHEVER IS LESS LONG TERM DEAD LOAD PLUS LIVE LOAD CONCRETE MI DESIGNS NOTES:. LIVE LOADS REDUCED PER OSSC. CONCRETE REINFORCEMENT. MEMBER DESIGNED FOR MORE CRITICAL OF UNIFORM OR CONCENTRATED LOAD. SNOW CRITERIA CONCRETE ANCHORAGES EMBEDDED STEEL ITEMS DESIGN ROOF SNOW LOAD 5 PSF MINIMUM IN ACCORDANCE WITH OSSC GROUND SNOW LOAD Pg= 0 PSF IN ACCORDANCE WITH 007 SNOW LOAD ANALYSIS FOR OREGON FLAT ROOF SNOW LOAD Pf = PSF SNOW EPOSURE FACTOR Ce =.0 STRUCTURAL STEEL STEEL WELDING PROCEDURES STEEL FASTENERS SNOW LOAD IMPORTANCE FACTOR Is =.0 THERMAL FACTOR Ct =.0 GEOTECHNICAL CRITERIA DESIGN BASED ON REPORT BY: G.R.I. DATED MARCH, 05 STAIRS AND RAILINGS FOOTNOTES: ALLOWABLE SOIL PRESSURE: NATIVE SANDY SOILS RISK CATEGORY SEISMIC DESIGN CATEGORY SITE CLASS SEISMIC CRITERIA,500 PSF IMPORTANCE FACTOR IE =.0 MCE SPECTRAL ACCELERATION Ss = 0.96 S = 0. SITE COEFFICIENT Fa =.0 Fv =.60 DESIGN SPECTRAL ACCELERATION SDS = 0.7 SD = 0. ANALYSIS PROCEDURE EQUIVALENT LATERAL FORCE PER ASCE 7-0, SECTION.8 SEISMIC LOAD RESISTING SYSTEM (SLRS) II D D DIRECTION (E / W) Y DIRECTION (N / S) LIGHT FRAMED WOOD SHEAR WALLS LIGHT FRAMED WOOD SHEAR WALLS RESPONSE MODIFICATION FACTOR R =.5 R =.5 SEISMIC RESPONSE COEFFICIENT Cs = 0.6 Cs = 0.6. SHOP DRAWINGS SHALL BE SUBMITTED TO THE ARCHITECT PRIOR TO FABRICATION AND CONSTRUCTION OF STRUCTURAL ITEMS. IF THE SHOP DRAWINGS DIFFER FROM OR ADD TO THE DESIGN OF THE STRUCTURAL DRAWINGS, THEY SHALL BEAR THE SEAL AND SIGNATURE OF A STRUCTURAL ENGINEER REGISTERED IN THE STATE OF OREGON. ANY CHANGES TO THE STRUCTURAL DRAWINGS SHALL BE SUBMITTED TO THE ARCHITECT AND ARE SUBJECT TO REVIEW AND ACCEPTANCE OF THE STRUCTURAL ENGINEER.. DESIGN DRAWINGS, SHOP DRAWINGS, AND CALCULATIONS FOR THE DESIGN AND FABRICATION OF ITEMS THAT ARE DESIGNED BY OTHERS SHALL BEAR THE SEAL AND SIGNATURE OF A STRUCTURAL ENGINEER REGISTERED IN THE STATE OF OREGON, AND SHALL BE SUBMITTED TO THE ARCHITECT PRIOR TO FABRICATION. CALCULATIONS SHALL BE INCLUDED FOR ALL CONNECTIONS TO THE STRUCTURE, CONSIDERING LOCALIZED EFFECTS ON STRUCTURAL ELEMENTS INDUCED BY THE CONNECTION LOADS. DESIGN SHALL BE BASED ON THE OF THE OSSC AND AS NOTED UNDER "DESIGN CRITERIA".. THE CONTRACTOR SHALL COORDINATE SEISMIC RESTRAINTS OF MECHANICAL, PLUMBING, AND ELECTRICAL EQUIPMENT, MACHINERY, AND ASSOCIATED PIPING WITH THE STRUCTURE. CONNECTIONS TO STRUCTURE SHALL CONFORM TO ASCE 7-0 CHAPTER, BE DESIGNED BY AN ENGINEER REGISTERED IN THE STATE OF OREGON, AND SHALL BE SUBMITTED TO THE ARCHITECT PRIOR TO FABRICATION.. FIELD ENGINEERED DETAILS DEVELOPED BY THE CONTRACTOR THAT DIFFER FROM OR ADD TO THE STRUCTURAL DRAWINGS SHALL BEAR THE SEAL AND SIGNATURE OF A STRUCTURAL ENGINEER REGISTERED IN THE STATE OF OREGON AND SHALL BE SUBMITTED TO THE ARCHITECT PRIOR TO CONSTRUCTION. DESIGN BASE SHEAR KIPS KIPS

2 GENERAL STRUCTURAL NOTES (CONT.) STRUCTURAL DRAWINGS ARE A PORTION OF THE CONTRACT DOCUMENTS AND ARE INTENDED TO BE USED WITH ARCHITECTURAL, MECHANICAL, AND ELECTRICAL DRAWINGS. THE CONTRACTOR IS RESPONSIBLE FOR COORDINATING THE FROM THESE DRAWINGS INTO THEIR SHOP DRAWINGS AND WORK. THESE GENERAL NOTES SUPPLEMENT THE PROJECT SPECIFICATIONS. REFER TO THE PROJECT SPECIFICATIONS FOR ADDITIONAL. NOTES AND DETAILS ON THE STRUCTURAL DRAWINGS SHALL TAKE PRECEDENCE OVER THE GENERAL NOTES AND TYPICAL DETAILS. WHERE NO DETAILS ARE GIVEN, CONSTRUCTION SHALL BE AS SHOWN FOR SIMILAR WORK. CODE : CONFORM TO THE 0 OREGON STRUCTURAL SPECIALTY CODE (OSSC), BASED ON THE 0 INTERNATIONAL BUILDING CODE (IBC). TEMPORARY CONDITIONS: SPACER ########## THE STRUCTURE IS DESIGNED TO FUNCTION AS A UNIT UPON COMPLETION. THE CONTRACTOR IS RESPONSIBLE FOR FURNISHING ALL TEMPORARY BRACING AND/OR SUPPORT THAT MAY BE REQUIRED AS THE RESULT OF THE CONTRACTOR'S CONSTRUCTION METHODS AND/OR SEQUENCES. REINFORCING STEEL: ALL LONGITUDINAL FLEURE REINFORCEMENT IN ABOVE GROUND LEVEL BEAMS, COLUMNS AND SHEAR WALLS SHALL BE ASTM A706, GRADE 60. ALL OTHER DEFORMED BAR REINFORCEMENT MAY BE ASTM A65 GRADE 60 OR ASTM A706 GRADE 60. REINFORCING STEEL SHALL BE DETAILED IN ACCORDANCE WITH THE "ACI MANUAL OF PRACTICE FOR DETAILING REINFORCED CONCRETE STRUCTURES," ACI 5. SHOP DRAWINGS SHALL INCLUDE ELEVATIONS OF ALL CONCRETE ELEMENTS SHOWING BAR LOCATIONS. LAP ALL REINFORCING BARS PER THE TYPICAL LAP SPLICE LENGTH SCHEDULES, ECEPT AS NOTED ON DRAWINGS. USE LAP LENGTH FOR SMALLER BAR WHEN SPLICING DIFFERENT BAR SIZES. BAR SIZE,000 FOUNDATION AND MAT LAP SPLICE LENGTH SCHEDULE (IN.),000 BOTTOM BARS (NOTE 7) TOP BARS (NOTE 7) 5,000,000,000 # 8 6 5,000 SAWN LUMBER: SAWN LUMBER SHALL CONFORM TO WEST COAST LUMBER BUREAU OR WESTERN WOOD PRODUCTS ASSOCIATION GRADING RULES. LUMBER SHALL BE KILN DRIED AND BE THE SPECIES AND GRADE NOTED BELOW: SAWN LUMBER USE SPECIES AND GRADE Fb () DIM. LUMBER " TO " THICK DOUGLAS FIR-LARCH NO. 900 T&G DECKING DOUGLAS FIR-LARCH COMMERCIAL DE 50 ALL LUMBER IN CONTACT WITH CONCRETE OR CMU SHALL BE PRESSURE TREATED, UNLESS AN APPROVED MOISTURE BARRIER IS PROVIDED. FRAMING ACCESSORIES AND STRUCTURAL FASTENERS SHALL BE MANUFACTURED BY SIMPSON STRONG TIE (OR APPROVED EQUAL) AND OF THE SIZE AND TYPE SHOWN ON THE DRAWINGS. ALL NAIL HOLES SHALL BE FILLED WITH STRUCTURAL FASTENERS, UNLESS NOTED OTHERWISE ON THE DRAWINGS AND FASTENERS SHALL BE INSTALLED FOLLOWING ALL MANUFACTURERS. IF A SUBSTITUTION IS MADE, A DOCUMENT SHALL BE SUBMITTED TO THE ARCHITECT FOR APPROVAL OUTLINING THE FRAMING ACCESSORIES BEING REPLACED AND THE SUBSTITUTED FRAMING ACCESSORIES. ALLOWABLE LOADS FOR THE SIMPSON ACCESSORIES SHALL BE TABULATED ALONG WITH ALLOWABLE LOADS FOR THE SUBSTITUTED ACCESSORIES, WHICH CLEARLY INDICATE THE SUBSTITUTED ACCESSORIES HAVING AN EQUAL OR GREATER CAPACITY. HANGERS NOT SHOWN SHALL BE SIMPSON U-TYPE OR B-TYPE OF SIZE RECOMMENDED FOR THE MEMBER. SW Fifth Ave., Suite 500 Portland, OR 970 O: CONTRACTOR'S CONSTRUCTION AND/OR ERECTION SEQUENCES SHALL RECOGNIZE AND CONSIDER THE EFFECTS OF THERMAL MOVEMENTS OF STRUCTURAL ELEMENTS DURING THE CONSTRUCTION PERIOD. EISTING CONDITIONS: ALL EISTING CONDITIONS, DIMENSIONS AND ELEVATIONS SHALL BE FIELD VERIFIED. THE CONTRACTOR SHALL NOTIFY THE ARCHITECT OF ANY SIGNIFICANT DISCREPANCIES FROM CONDITIONS SHOWN ON THE DRAWINGS. ASSUMED FUTURE CONSTRUCTION: VERTICAL: NONE HORIZONTAL: NONE DESIGN CRITERIA: DESIGN WAS BASED ON THE STRENGTH AND DEFLECTION CRITERIA OF THE OSSC. IN ADDITION TO THE DEAD LOADS, THE FOLLOWING LOADS AND ALLOWABLES WERE USED FOR DESIGN, WITH LIVE LOADS (L.L.) REDUCED PER OSSC: CONCRETE: CONCRETE WORK SHALL CONFORM TO CHAPTER 9 OF THE OSSC. CONCRETE STRENGTHS SHALL BE VERIFIED BY CYLINDER TESTS PER ASTM C9. MI DESIGNS SHALL BE AS FOLLOWS: # # TABLE NOTES:. MINIMUM LAP SPLICES NOTED ARE FOR NON-LATERAL LOAD RESISTING ELEMENTS. FOR REBAR LAPS SPLICES AT LATERAL LOAD RESISTING ELEMENTS, PLANS AND ELEVATIONS.. ASTM A65 OR ASTM A706, GRADE 60 DEFORMED REINFORCING BARS. MINIMUM CLEAR COVER AND BAR SPACING of db TO BE PROVIDED.. NORMAL WEIGHT CONCRETE, FOR LIGHT-WEIGHT CONCRETE MULTIPLY TABLE VALUES BY.. 5. UNCOATED BARS, FOR EPOY-COATED BARS MULTIPLY TABLE VALUES BY COMBINATIONS OF EFFECTS DUE TO CONCRETE STRENGTH, CONCRETE WEIGHT, AND EPOY COATING ARE CUMULATIVE. SLAB AND FOUNDATION TOP BARS ARE BARS CAST ABOVE MORE THAN " OF FRESH CONCRETE. ALL OTHER SLAB BARS MAY BE CONSIDERED BOTTOM BARS. REINFORCING STEEL SHALL HAVE PROTECTION AS FOLLOWS: ALL FRAMING NAILS SHALL BE OF THE SIZE AND NUMBER INDICATED ON THE DRAWINGS AND CONFORM TO ASTM F 667, " SPECIFICATION OF DRIVEN FASTENERS: NAILS, SPIKES, AND STAPLES AND NER-7 "POWER-DRIVEN STAPLES AND NAILS FOR USE IN ALL TYPES OF BUILDING CONSTRUCTION." NAILS SHALL BE IDENTIFIED BY LABELS (ATTACHED TO THEIR CONTAINERS) THAT SHOW THE MANUFACTURER'S NAME AND NES REPORT NUMBER, NAIL SHANK DIAMETER, AND LENGTH AND SHALL BE SUBMITTED TO THE ARCHITECT PRIOR TO FRAMING. NAILING NOT SHOWN SHALL BE AS INDICATED ON OSSC TABLE 0.9. OR NER-7. THE FOLLOWING NAIL SIZES SHALL BE USED: NAIL TYPE FRAMING NAILS SHANK DIAMETER (IN.) MINIMUM PENETRATION INTO FRAMING MEMBER (IN.) 6d d d BOLTS AND LAG SCREWS SHALL CONFORM TO ANSI/ASME B ALL BOLTS AND LAG SCREWS SHALL BE INSTALLED WITH CUT WASHERS. ALL A07 BOLTS SHALL HAVE CUT THREADS. EPIRES USE CONCRETE MI DESIGNS f'c () TEST AGE (DAYS) MA. W/CM RATIO (NOTE ) MA. AGGREGATE SIZE SPREAD FOOTINGS, " ETERIOR SLABS ON GRADE, /" USE WALLS: EPOSED TO EARTH OR WEATHER REINFORCING STEEL CONCRETE COVER CLEAR COVER -/" (#5 AND SMALLER) " (#6 AND LARGER) CUTTING AND NOTCHING OF JOISTS AND STUDS SHALL CONFORM TO OSSC SECTIONS 08..., AND WOOD STRUCTURAL PANELS: WOOD STRUCTURAL PANELS SHALL CONFORM TO THE OF "U.S. PRODUCT PS FOR CONSTRUCTION AND INDUSTRIAL PLYWOOD", "U.S. PRODUCT PS PERFORMANCE FOR WOOD-BASED STRUCTURAL-USE PANELS", OR "APA PRP-08 PERFORMANCE S". UNLESS NOTED, PANELS SHALL BE APA RATED SHEATHING, EPOSURE, OF THE THICKNESS AND SPAN RATING SHOWN ON THE DRAWINGS. TABLES NOTES:. VERIFY WATER-CEMENTITOUS MATERIAL RATIO WITH FLOOR COVERING MANUFACTURER FOR CONCRETE FLOORS WITH MOISTURE SENSITIVE FLOOR COVERINGS.. ESTABLISH WATER-CEMENTITOUS MATERIAL RATIO PER ACI 8- CHAPTER 5.. EPOSED SLAB GENERAL NOTES FOR ADDITIONAL MI. PORTLAND CEMENT CONTENT MAY BE REPLACED UP TO 0% WITH FLYASH CONFORMING TO ASTM C68 (INCLUDING TABLE A) TYPE F OR TYPE C OR UP TO 50% WITH SLAG CEMENT CONFORMING TO ASTM C989, PROVIDED THAT THE MI STRENGTH IS SUBSTANTIATED BY TEST DATA. FOR MI DESIGNS WITH 5,000 OR LESS, SLAG CEMENT MAY BE SUBSTITUTED FOR FLYASH AT A : RATIO WITHOUT TEST DATA. WHEN SLAG CEMENT IS SUBSTITUTED IN HIGHER STRENGTH MIES OR AT DIFFERENT RATIO, THE MI STRENGTH MUST BE SUBSTANTIATED BY TEST DATA. CONCRETE CAST AGAINST AND EPOSED TO EARTH " CONCRETE ACCESSORIES: POST-INSTALLED ANCHORS SHALL BE OF THE TYPE AND PRODUCT SPECIFIED ON THE DRAWINGS OR AS FOLLOWS: TYPE EPANSION CONCRETE SCREW EPOY ADHESIVE POST INSTALLED CONCRETE ANCHORS APPROVED ANCHORS [HILTI KWIK BOLT TZ (ICC ESR-97)] [SIMPSON STRONG-BOLT (ICC ESR-07)] [POWERS POWER-STUD+ SD (ESR-50)] [HILTI KWIK HUS-EZ (ICC ESR-07)] [SIMPSON TITEN HD (ICC ESR-7)] [POWERS WEDGE-BOLT+ (ESR-56)] [HILTI HIT-HY00 (ICC ESR-87)] [SIMPSON SET-P (ICC ESR-508)] [POWERS PURE0+ (ESR-98)] WOOD STRUCTURAL PANEL INSTALLATION SHALL BE IN CONFORMANCE WITH APA RECOMMENDATIONS. ALLOW /8" SPACING AT PANEL ENDS AND EDGES, UNLESS OTHERWISE RECOMMENDED BY THE PANEL MANUFACTURER. ALL FLOOR SHEATHING SHALL BE INSTALLED WITH FACE GRAIN PERPENDICULAR TO SUPPORTS, ECEPT AS INDICATED ON THE DRAWINGS. FLOOR SHEATHING SHALL BE UNBLOCKED, ECEPT AS INDICATED ON DRAWINGS. SUB-FLOOR PANELS SHALL BE FIELD GLUED TO THE FRAMING USING ADHESIVES MEETING APA SPECIFICATION AFG-0 OR ASTM D98. TONGUE AND GROOVE PANELS SHALL ALSO BE GLUED AT THE T&G JOINT. ALL NAILS SHALL BE RING SHANK FOR FLOOR SHEATHING. NAIL HEADS SHALL BE DRIVEN FLUSH WITH SHEATHING. DO NOT PENETRATE SURFACE PLY WITH NAIL HEADS. IF NAIL HEADS ARE NOT FLUSH NOTIFY E.O.R. A WATER-REDUCING ADMITURE CONFORMING TO ASTM C9 USED IN STRICT ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS SHALL BE INCORPORATED IN CONCRETE DESIGN MIES. A HIGH-RANGE WATER-REDUCING (HRWR) ADMITURE CONFORMING TO ASTM C9 TYPE F OR G MAY BE USED IN CONCRETE MIES PROVIDING THAT THE SLUMP DOES NOT ECEED 0". AN AIR-ENTRAINING AGENT CONFORMING TO ASTM C60 SHALL BE USED IN CONCRETE MIES FOR ALL CONCRETE EPOSED TO WEATHER. THE AMOUNT OF ENTRAINED AIR BY VOLUME SHALL BE AS FOLLOWS ±.5%: MA. AGGREGATE SIZE CONCRETE MI AIR CONTENT CONCRETE SUBJECT TO FREEZE/THAW CONCRETE SUBJECT TO CONT. MOISTURE AND/OR DEICING CHEMICALS ALL ANCHORS SHALL BE INSTALLED IN STRICT CONFORMANCE WITH THE MANUFACTURER'S RECOMMENDATIONS AND PRODUCT EVALUATION REPORTS. REQUESTS FOR ANCHOR SUBSTITUIONS SHALL BE SUBMITTED TO THE EOR IN WRITING ALONG WITH EVIDENCE OF EQUAL OR GREATER CAPACITY TO THE SPECIFIED CONNECTION. DO NOT CUT REINFORCING IN NEW OR EISTING CONCRETE DURING INSTALLATION. ANCHORS EPOSED TO EARTH OR WEATHER SHALL BE PROTECTED FROM CORROSION BY HOT-DIP GALVANIZING OR USE OF STAINLESS STEEL. PERMANENTLY EPOSED EMBEDDED PLATES AND ANGLES SHALL BE HOT-DIPPED GALVANIZED AFTER FABRICATION, UNLESS NOTED OTHERWISE. NO LOADS OR WELDS SHALL BE PLACED ON EMBEDDED PLATES OR ANGLES FOR A MINIMUM OF 7 DAYS AFTER CASTING. STRUCTURAL STEEL: STRUCTURAL STEEL SHALL BE: /" 5.0% 6.0% ".5% 6.0% -/".5% 5.5% CONCRETE ELEMENTS SUBJECT TO FREEZE/THAW INCLUDE ALL SIDEWALKS AND ETERIOR SLABS. MATERIAL GRADE ASTM A57, GRADE 50 ASTM A6 ASTM A500, GRADE B (FY=6KSI) ASTM A5, GRADE B (FY=5 KSI) STRUCTURAL STEEL SHAPE PLATES WHERE NOTED CHANNELS, PLATES AND ANGLES, ECEPT AS NOTED HOLLOW STRUCTURAL SECTIONS (TUBES) PIPES THE CONTRACTOR SHALL SUBMIT CONCRETE MI DESIGNS ALONG WITH TEST DATA COMPLIANT WITH ACI 8- OSSC SECTION 905 A MINIMUM OF TWO WEEKS PRIOR TO PLACING CONCRETE. NO WATER MAY BE ADDED TO CONCRETE IN THE FIELD UNLESS SPECIFICALLY APPROVED IN WRITING BY THE CONCRETE SUPPLIER IN CONJUNCTION WITH THE CONCRETE MI DESIGN. WHERE NEW CONCRETE IS PLACED AGAINST EISTING CONCRETE, THE EISTING CONCRETE SURFACE SHALL BE CLEANED AND ROUGHENED TO A MINIMUM /" AMPLITUDE PER ACI 8 SECTION.6.9. PROVIDE /" CHAMFERS ON ALL EPOSED CONCRETE EDGES, UNLESS NOTED OTHERWISE. DESIGN, FABRICATION, AND ERECTION SHALL BE IN ACCORDANCE WITH THE "AISC SPECIFICATION FOR THE DESIGN, FABRICATION, AND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS" WITH "COMMENTARY" AND THE "CODE OF PRACTICE", WITH ECEPTIONS NOTED IN SPECIFICATIONS. BOLTS SHALL CONFORM TO THE ASTM AND RCSC SPECIFICATIONS FOR JOINTS USING A5 OR A90 HIGH STRENGTH BOLTS. BOLTS SHALL BE SNUG-TIGHT UNLESS NOTED OTHERWISE. WELDING SHALL CONFORM TO THE AWS CODES FOR ARC AND GAS WELDING IN BUILDING CONSTRUCTION. WELDING SHALL BE PERFORMED IN ACCORDANCE WITH A WELDED PROCEDURE SPECIFICATION (WPS) AS REQUIRED IN AWS D. AND APPROVED BY THE STRUCTURAL ENGINEER. THE WPS VARIABLES SHALL BE WITHIN THE PARAMETERS ESTABLISHED BY THE FILLER-METAL MANUFACTURER. FOR MEMBERS INCLUDED IN THE SEISMIC LOAD RESISTING SYSTEM (SLRS), OF AWS D.8 (SEISMIC SUPPLEMENT) SHALL APPLY ALL WELDS USED IN MEMBERS AND CONNECTIONS THAT ARE PART OF THE SEISMIC LOAD RESISTING SYSTEM (SLRS) SHALL BE MADE WITH A FILLER METAL THAT HAS A MINIMUM CHARPY V-NOTCH (CVN) TOUGHNESS OF 0 FT-LBS AT 0 DEGREES F, AS DETERMINED BY AWS CLASSIFICATION OR MANUFACTURER CERTIFICATION. FOR MEMBERS AND CONNECTIONS THAT ARE PART OF THE SEISMIC LOAD RESISTING SYSTEM, DISCONTINUITIES CREATED BY ERRORS OR BY FABRICATION OR ERECTION OPERATIONS, SUCH AS TACK WELDS, ERECTION AIDS, AIR-ARC GOUGING, AND FLAME CUTTING, SHALL BE REPAIRED AS REQUIRED BY THE STRUCTURAL ENGINEER. WELDS SHALL BE MADE USING E70 ELECTRODES AND SHALL BE /6" MINIMUM, UNLESS OTHERWISE NOTED. WELDING SHALL BE BY AWS CERTIFIED WELDERS MEETING CITY OF PORTLAND S. PROVIDE WEEP HOLES AT ETERIOR CLOSED SECTIONS WHERE MOISTURE MAY ACCUMULATE.

3 SPACER ########## TABLE - REQUIRED GEOTECHNICAL SPECIAL S SPECIAL S TABLE (CONT.) - REQUIRED STRUCTURAL SPECIAL S S SW Fifth Ave., Suite 500 Portland, OR 970 O: SOILS POST INSTALLED CONCRETE ANCHORS VERIFY MATERIALS BELOW FOOTINGS ARE ADEQUATE TO ACHIEVE THE DESIGN BEARING CAPACITY VERIFY ECAVATIONS ARE ETENDED TO PROPER DEPTH AND HAVE REACHED PROPER MATERIAL PERFORM CLASSIFICATION AND TESTING OF CONTROLLED FILL MATERIALS VERIFY USE OF PROPER MATERIALS, DENSITIES AND LIFT THICKNESSES DURING PLACEMENT AND COMPACTION OF CONTROLLED FILL PRIOR TO PLACEMENT OF CONTROLLED FILL, OBSERVE SUBGRADE AND VERIFY THAT SITE HAS BEEN PREPARED PROPERLY GEOTECHNICAL REPORT BY THE GEOTECHNICAL ENGINEER POST INSTALLED ANCHORS INSTALLATION IN HARDENED CONCRETE AND COMPLETED MASONRY FABRICATION OF PREFABRICATED STRUCTURAL ELEMENTS. FABRICATION OF DIAPHRAGMS: A. VERIFY STRUCTURAL PANEL GRADE AND THICKNESS B. VERIFY NOMINAL SIZE OF FRAMING MEMBERS AT ADJOINING PANEL EDGES ACI 8:.,.8.6 (NOTE 8) WOOD TABLE 06. () TABLE 06. () PER ICC EVALUATION REPORT REFER TO OF FABRICATOR TABLE - REQUIRED STRUCTURAL SPECIAL S C. VERIFY NAIL DIAMETER AND LENGTH AND SPACING BETWEEN FASTENERS IN EACH LINE AND AT EDGES TABLE 06. () TABLE A - REQUIRED STRUCTURAL STEEL SPECIAL S EPIRES FABRICATORS FABRICATORS DEFERRED SUBMITTALS DEFERRED SUBMITTALS GENERAL REINFORCING STEEL PLACEMENT OF CAST-IN-PLACE BOLTS VERIFYING USE OF REQUIRED MI DESIGN(S) CONCRETE ACI 8. ACI 8.5 ACI 8 7. TO 7.7 ACI 8, CH. ACI CONCRETE PLACEMENT, NON-SHRINK GROUT ACI CONCRETE/SHOTCRETE CURING 90.9 ACI VERIFICATION OF IN-SITU CONCRETE STRENGTH PRIOR TO STRESSING OF TENDONS IN POST-TENSIONED CONCRETE PRESTRESSED / POST-TENSIONED CONCRETE ACI APPLICATION OF PRESTRESSING FORCES ACI GROUTING OF BONDED PRESTRESSING TENDONS IN THE SEISMIC FORCE RESISTING SYSTEM ACI ERECTION OF PRECAST MEMBERS ACI 8 CH. 6 VERIFICATION OF IN-SITU CONCRETE PRIOR TO REMOVAL OF FORMS AND SHORES FROM ELEVATED BEAMS AND SLABS ACI 8 6. VERIFICATION OF FORMWORK ACI EMBEDDED ITEMS IN CONCRETE STEEL TABLE A FOR REQUIRED SPECIAL S FOR STEEL STAINLESS STEEL FABRICATION OF STAINLESS STEEL ELEMENTS SPECIAL IS REQUIRED FOR STRUCTURAL LOAD-BEARING MEMBERS AND ASSEMBLIES FABRICATED ON THE PREMISES OF A FABRICATOR'S SHOP PER TABLE AND AS REQUIRED ELSEWHERE IN THE SPECIAL PROGRAM. THE SPECIAL INSPECTOR SHALL VERIFY THAT THE FABRICATOR MAINTAINS DETAILED FABRICATION AND QUALITY CONTROL PROCEDURES AND SHALL REVIEW FOR COMPLETENESS AND ADEQUACY RELATIVE TO THE CODE REQUIREMENT. SECTION FOR APPROVED FABRICATOR ECEPTION. SPECIAL FOR DEFERRED SUBMITTAL ITEMS TO BE SPECIFIED BY THE SYSTEMS ENGINEER AND INCLUDED WITH DEFERRED SUBMITTAL DOCUMENTS. SPECIAL S OF CONCRETE SHALL CONFORM TO THE OF SECTION 705. OF THE OSSC AND SECTION. OF ACI 8. REINFORCING TO COMPLY WITH ALL CODE PROTECTION, SPACING AND TOLERANCE LIMITS. ALL BOLTS VISUALLY INSPECTED ALL CONNECTIONS VISUALLY INSPECTED. REFER TO ANCHOR BOLT AND WELDING SPECIAL S APPLY TO SHAPE, LOCATION AND DIMENSIONS OF THE CONCRETE MEMBER BEING FORMED ALL NON-STRUCTRAL EMBEDDED ITEMS, SUCH AS CONDUITS, PIPES AND SLEEVES, SHALL BE REVIEWED FOR CONFORMANCE WITH STRUCTURAL DOCUMENTS FOR SIZE, SPACING, LOCATION, EDGE DISTANCE AND TRIM REINFORING. REFER TO OF FABRICATOR MATERIAL VERIFICATION OF STAINLESS STEEL CERTIFIED MILL TEST REPORTS MATERIAL VERIFICATION OF BOLTS MANUFACTURER'S CERTIFIED TEST REPORTS CONTRACTOR QUALITY CONTROL STEEL FABRICATION AISC 60 CHAPTER N (NOTES 5 AND 6) OBSERVE PERFORM STEEL FABRICATION OF STRUCTURAL ELEMENTS AISC 60 N MATERIAL VERIFICATION OF STRUCTURAL STEEL FOR OTHER STEEL, IDENTIFICATION MARKINGS TO CONFORM TO ASTM S SPECIFIED IN THE APPROVED CONSTRUCTION DOCUMENTS MATERIAL VERIFICATION OF WELD FILLER METALS STRUCTURAL STEEL WELDING TABLE 705. TABLE 705. TABLE 705. ASTM A6 ASTM S SPECIFIED IN CONSTRUCTIO N DOCUMENTS AISC 60 A. AISC 60 N. APPLICABLE ASTM S AISC 60 A.5 AISC 60 N. APPLICABLE AWS A5 DOCUMENTS VERIFYING USE OF PROPER WPS'S AISC 60 N. VERIFYING WELDER QUALIFICATIONS COMPLETE AND PARTIAL JOINT PENETRATION GROOVE WELDS MULTIPASS FILLET WELDS SINGLE PASS FILLET WELDS GREATER THAN 5/6" PLUG AND SLOT WELDS SINGLE PASS FILLET WELDS LESS THAN OR EQUAL TO 5/6" TABLE 705. WELDING STAIR AND RAILING SYSTEMS 705.(.5) TS AWS D. SECTION 6 AWS D. SECTION 6 CONTRACTOR TO PROVIDE QUALITY CONTROL FOR ALL ITEMS INDICATED TO BE OBSERVE AND/OR PERFORM IN TABLE BELOW REFER TO OF FABRICATOR CERTIFIED MILL TEST REPORTS MANUFACTURER'S CERTIFIED TEST REPORTS MANUFACTURER'S CERTIFIED TEST REPORTS RETAIN A RECORD OF WELDING PROCEDURE SPECIFICATIONS RETAIN A RECORD OF QUALIFICATION CARDS ALL WELDS VISUALLY INSPECTED PER AWS D.6.9 ALL WELDS VISUALLY INSPECTED PER AWS D. 6.9 MATERIAL VERIFICATION OF WELD FILLER METALS MANUFACTURER'S CERTIFIED TEST REPORTS VERIFYING USE OF PROPER WPS'S RETAIN A RECORD OF WELDING PROCEDURE SPECIFICATIONS VERIFYING WELDER QUALIFICATIONS AWS D.6 SECTION 6 RETAIN A RECORD OF QUALIFICATION CARDS COMPLETE AND PARTIAL PENETRATION GROOVE WELDS ALL WELDS VISUALLY INSPECTED PER AWS D.6 MULTIPASS FILLET WELDS 6.8. SINGLE PASS FILLET WELDS

4 SPECIAL S (CONT.) NAILING, BOLTING, ANCHORING, AND OTHER FASTENING OF COMPONENTS WITHIN THE MAIN WIND-FORCE RESISTING SYSTEM, INCLUDING WOOD SHEAR WALLS, WOOD DIAPHRAGMS, COLLECTORS, BRACES, AND HOLDOWNS SPACER ########## TABLE 5 - REQUIRED SPECIAL S FOR WIND RESISTANCE WOOD SPECIAL S ARE NOT REQUIRED FOR WOOD SHEAR WALLS AND DIAPHRAGMS WHERE FASTENER SPACING IS MORE THAN INCHES ON CENTER. REFER TO TABLE FOR MATERIAL SPECIFIC STATEMENT OF SPECIAL NOTES:. SPECIAL S SHALL CONFORM TO SECTION 705 OF THE 0 OSSC, CONTRACT DOCUMENTS AND APPROVED SUBMITTALS. REFER TO TABLES THROUGH 5 FOR SPECIAL AND TABLES 6, 7 AND 7A FOR TESTING.. SPECIAL S AND ASSOCIATED TESTING SHALL BE PERFORMED BY AN APPROVED ACCREDITED INDEPENDENT AGENCY MEETING THE OF ASTM E9 (MATERIALS). THE AND TESTING AGENCY SHALL FURNISH TO THE ARCHITECT A COPY OF THEIR SCOPE OF ACCREDITATION. SPECIAL INSPECTORS SHALL BE APPROVED BY THE BUILDING OFFICIAL. WELDING INSPECTORS SHALL BE QUALIFIED PER SECTION 6... OF AWS D... THE SPECIAL INSPECTOR SHALL OBSERVE THE INDICATED WORK FOR COMPLIANCE WITH THE APPROVED CONSTRUCTION DOCUMENTS. ALL DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE CONTRACTOR FOR CORRECTION AND NOTED IN THE REPORTS. SW Fifth Ave., Suite 500 Portland, OR 970 O: FIELD GLUING OPERATIONS OF ELEMENTS OF MAIN WIND-FORCE-RESISTING SYSTEM TESTING TABLE 6 - REQUIRED TESTING FOR SPECIAL S. THE SPECIAL INSPECTOR AND GEOTECHNICAL ENGINEER SHALL FURNISH REPORTS FOR EACH TO THE BUILDING OFFICIAL, ENGINEER, ARCHITECT, CONTRACTOR, AND OWNER. THE SPECIAL AGENCY SHALL SUBMIT A FINAL REPORT STATING THAT THE WORK REQUIRING SPECIAL WAS INSPECTED AND IS IN CONFORMANCE WITH THE APPROVED CONSTRUCTION DOCUMENTS AND THAT ALL DISCREPANCIES NOTED IN THE REPORTS HAVE BEEN CORRECTED. 5 FOR STEEL S PER AISC 60 AND (TABLES A): QUALITY ASSURANCE (QA) IS REQUIRED FOR EACH ITEM IN TABLES UNLESS SPECIFICALLY NOTED OTHERWISE. QUALITY CONTORL (QC) TO BE PROVIDED BY THE FABRICATOR, ERECTOR OR OTHER RESPONSIBLE CONTRACTOR AS APPLICABLE. CONTRACTOR AND SPECIAL INSPECTOR TO DOCUMENT QUALITY CONTROL AS REQUIRED IN AISC 60 SECTION N AND AISC SECTION J. 6 TYPES EPIRES CONCRETE : THE FULL-TIME OBSERVATION OF WORK REQUIRING SPECIAL BY AN APPROVED SPECIAL INSPECTOR WHO IS PRESENT IN THE AREA WHERE THE WORK IS BEING PERFORMED. CONCRETE STRENGTH CONCRETE SLUMP CONCRETE AIR CONTENT 705. ASTM C7 ASTM C ACI8:5.6,5.8 ASTM C9 ASTM C ASTM C EACH 50 CY NOR LESS THAN EACH 5000 SF OF SLAB OR WALL PLACED EACH SHIFT FABRICATE SPECIMENS AT TIME FRESH CONCRETET IS PLACED : THE PART-TIME OR INTERMITTENT OBSERVATION OF WORK REQUIRING SPECIAL BY AN APPROVED SPECIAL INSPECTOR WHO IS PRESENT IN THE AREA WHERE THE WORK HAS BEEN OR IS BEING PERFORMED AND AT THE COMPLETION OF THE WORK. OBSERVE : OBSERVE THESE FUNCTIONS ON A RANDOM, DAILY BASIS. OPERATIONS NEED NOT BE DELAYED PENDING OBSERVATIONS. PERFORM : S SHALL BE PERFORMED PRIOR TO THE FINAL ACCEPTANCE OF THE ITEM. CONCRETE TEMPERATURE ASTM C06 7 PERFORM PRIOR TO FINAL ACCEPTANCE OF THE ITEM FOR TEN WELDS TO BE MADE BY A GIVEN WELDER, WITH THE WELDER DEMONSTRATING UNDERSTANDING OF AND POSSESSION OF SKILLS AND TOOLS TO VERIFY THESE ITEMS, THE PERFORM DESIGNATION OF THIS TASK SHALL BE REDUCED TO OBSERVE, AND THE WELDER SHALL PERFORM THIS TASK. SHOULD THE INSPECTOR DETERMINE THAT THE WELDER HAS DISCONTINUED PERFORMANCE OF THIS TASK, THE TASK SHALL BE RETURNED TO PERFORM UNTIL SUCH TIME AS THE INSPECTOR HAS RE-ESTABLISHED ADEQUATE ASSURANCE THAT THE WELDER WILL PERFORM THE TASKS LISTED 8 SPECIAL OF MECHANICAL POST INSTALLED ANCHORS SHALL BE IN STRICT CONFORMANCE WITH THE ICC REPORT AND MANUFACTURERS INSTALLATION. ANCHOR INSTALLERS SHALL BE QUALIFIED AS REQUIRED BY JURISDICTION. REPORTS SHALL IDENTIFY NAMES OF INSTALLERS. SPECIAL INSPECTOR SHALL PROVIDE DOCUMENTATION AT THE END OF ANCHOR INSTALLATIONS STATING THAT THE ANCHORS WERE INSPECTED PER APPROVED ANCHOR EVAULATION REPORT. 9 DOCUMENT (D): INDICATES CONTRACTOR AND SPECIAL INSPECTOR TO PROVIDE DOCUMENTATION IN ACCORDANCE WITH AISC. CONTRACTOR RESPONSIBILITY: THE CONTRACTOR RESPONSIBLE FOR THE CONSTRUCTION OF THE MAIN WIND-OR SEISMIC-FORCE-RESISTING SYSTEM, OR A WIND-OR SEISMIC-RESISTING COMPONENT LISTED IN TABLE 5 SHALL SUBMIT A WRITTEN STATEMENT OF RESPONSIBILITY TO THE BUILDING OFFICIAL AND THE OWNER PRIOR TO THE COMMENCEMENT OF WORK ON THE SYSTEM OR COMPONENT. THE CONTRACTOR'S STATEMENT OF RESPONSIBILITY SHALL CONTAIN THE FOLLOWING: ACKNOWLEDGEMENT OF AWARENESS OF THE SPECIAL CONTAINED IN THE STATEMENT OF SPECIAL S.. ACKNOWLEDGEMENT THAT CONTROL WILL BE EERCISED TO OBTAIN CONFORMANCE WITH THE CONSTRUCTION DOCUMENTS APPROVED BY THE BUILDING OFFICIAL.. PROCEDURES FOR EERCISING CONTROL WITHIN THE CONTRACTOR'S ORGANIZATION, THE METHOD AND FREQUENCY OF REPORTING AND DISTRIBUTION OF THE REPORTS.. IDENTIFICATION AND QUALIFICATIONS OF THE PERSON(S) EERCISING SUCH CONTROL AND THEIR POSITION(S) IN THE ORGANIZATION.

5 SW Fifth Ave., Suite 500 Portland, OR 970 O: EPIRES 7 OVERALL PLAN - BUILDINGS A AND B /8"='-0"

6 DN '-" (E) WALL LEDGER TO REMAIN 6'- 6" '-0" (E) BUILDING B STUD WALL SW Fifth Ave., Suite 500 Portland, OR 970 O: '-" HSS0xx HSS5x5 STAIR POSTS BELOW REF. S. HSS0xx HSS0xx 7 8 DN UP HSS0xx 8 HSS0xx HSS0xx (8) HSS6x6x DECK POSTS EPIRES (8) HSS5x5x STAIR POSTS HSS0xx '-" cc INTERMEDIATE HSS xx RAILING POSTS () LOCATIONS 7'-6" cc HSS0xx 6 '-5" cc PARTIAL FRAMING PLAN - BUILDING B DECK AND STAIR PLAN /"='-0" 8'-0" (E) WALL LEDGER TO REMAIN (E) BUILDING A STUD WALL '-5" AGAINST CURB LOCATIONS '-" UP HSS0xx (5) HSS6x6x DECK POSTS HSS0xx HSS5x5 STAIR POST BELOW REF. S. HSS0xx 9'-7" (8) HSS5x5x STAIR POSTS 7'-6" HSS0xx HSS0xx INTERMEDIATE HSS xx RAILING POSTS () LOCATIONS 6 PARTIAL FRAMING PLAN - BUILDING A DECK AND STAIR PLAN /"='-0"

7 RAILING SYSTEM REF. /S6.0 HSS POSTS REF. PLAN " SQ. BAR AT " o.c. SPACING " '-0 9 6" CLEAR MAIMUM LENGTH " SQ. BAR TOP AND BOTTOM (N) STEEL RAILING () SIDES OF DECK REF. /S6. SW Fifth Ave., Suite 500 Portland, OR 970 O: LANDING DECK "x0 GAUGE TYPE W PLUS " TOPPING SLAB (W.xW. WWF) Lxx CONT. DECK LEADERS TO HSS0x BEAMS DECK STRINGER '-" " HSS0xx 8 BEAM '-0" ETENSION (N) 7 6" CD SHEATHINGETERIOR GRADE w/ 8d SCREWS AT 6'' o.c. EDGE/" o.c. FIELD TO JOISTS AND GIRDERS (E) BUILDING WALL LEVEL EL..' TO BE FIELD VERIFIED ( ( ) ) 6 STAIR LANDING SECTION "='-0" HSS6xx " LANDING BEAM HSS0x EDGE BEAMS REF. PLAN STEEL RAILING SYSTEM REF. /S6. NOTE: REF. ARCH. FOR RAILING DIMENSIONS NOT SHOWN. INTERMEDIATE HSSxx RAILING POSTS AS REQIRED STEEL RAILING AT DECK AND STAIRS "='-0" HSSx5x5x POSTS (E) x8 WALL LEDGER TO REMAIN (N) x8 # D-F-L 6" o.c. w/ SIMPSON LU6 HANGER EACH END ±'-0" HEIGHTS (VARIES w/ GROUND FINISH) REF. CIVIL SITE PLAN EPIRES STAIR STRINGER AND TREADS REF. /S6. (N) STEEL RAILING, REF. /S6. '-0" CLEAR TREAD CONCRETE FILLED PAN TREADS '-0" HSS POST AND FOOTING REF. PLAN 6" MIN. (E) CONC. WALL 5 BASE PL x0x0'-0 w/ () ''Øx8'' 7'' o.c. THICKENED SLAB EDGE AT STRINGER BASE FOOTING REF. /S6. Lxx 5 6x0'-6" w/ () 8 "Øx" EMBEDMENT EPANSION " o.c. HSS0xx STEEL STAIR STRINGER, FOOTING '-0"x'-0"x" DEEP ('-0"x'-0"x" DEEP AT WALL) w/ () # EACH WAY BOTTOM REINF. UNDISTURBED NATIVE SOILS OR 6" LAYER OF COMPACTED GRAVELS () # EPOY DOWELS w/ " EMBEDMENT INTO (E) WALL 7 STAIR BASE CONNECTION "='-0" TYPICAL STAIR FRAME SECTION "='-0" TYPICAL DECK FRAMING SECTION "='-0" PL " CAP w/ SEAL WELD ALL AROUND, ALL POSTS PL GA. TRADE SYSTEM FULL END RET. 8 REF. ARCH. " CONCRETE PAN FILL AT EACH TRADE REF. ARCH. REF. ARCH. (N) 7 8" CD SHEATHING REF. /S6. " '-" " STEEL RAILING, REF. ARCH PLANS AND /S Lxx0'-8" TRADE SUPPORT EACH END HSS POST AND BEAM, REF. /S6. 5 TYPICAL STAIR TREAD SECTION "='-0" DECK END FRAME SECTION "='-0"

Statement of Special Inspections 2013 CBC

Statement of Special Inspections 2013 CBC BUILDIG & SAFET DIVISIO 2729 Prospect Park Drive Rancho Cordova, CA 95670 Phone: (916) 851-8760 Fax: (916) 851-8762 Statement of Special Inspections 2013 CBC PERMIT #: PROJECT ADDRESS: This Statement of

More information

Statement of Special Inspections Michigan Building Code 2012 (MBC 2012)

Statement of Special Inspections Michigan Building Code 2012 (MBC 2012) Gaines Charter Township 8555 Kalamazoo Ave SE Caledonia MI 49316 PH: 616 698-6640 Fax: 616 698-2490 www.gainestownship.org Building Department Statement of Special Inspections Michigan Building Code 2012

More information

STATEMENT OF SPECIAL INSPECTION FORM

STATEMENT OF SPECIAL INSPECTION FORM Project Title: Permit #: Project Address: STATEMENT OF SPECIAL INSPECTION FORM This Statement of Special Inspections is submitted in fulfillment of the requirements of CBC Sections 1704 and 1705. Special

More information

Structural Tests and Special Inspections Form. Inspection of Fabricators (1704.2)

Structural Tests and Special Inspections Form. Inspection of Fabricators (1704.2) Inspection of Fabricators (1704.2) Furnish inspection reports (1704.2.1) - Fabricators that have not been approved Provide a Certificate of Compliance (1704.2.2) - Approved Fabricators Steel Construction

More information

Statement of Special Inspection Requirements

Statement of Special Inspection Requirements Statement of Special Inspection Requirements California Building Code Chapter 17 Construction plans shall include a statement of special inspection in accordance with CBC chapter 17. The statement of special

More information

Mechanical Engineer of Record: (Smoke Control Systems Only) Name & License Company. Others: Responsible Party Name & License Company

Mechanical Engineer of Record: (Smoke Control Systems Only) Name & License Company. Others: Responsible Party Name & License Company PRINCE WILLIAM COUNTY Department Development Services Building Development Division STATEMENT OF SPECIAL INSPECTIONS (Building/Other Structures other than Retaining Walls) Version 2015-12-31 Building Permit

More information

PLANNING DEPARTMENT 701 OCEAN STREET, 4 TH FLOOR, SANTA CRUZ, CA (831) FAX: (831)

PLANNING DEPARTMENT 701 OCEAN STREET, 4 TH FLOOR, SANTA CRUZ, CA (831) FAX: (831) County of Santa Cruz PLANNING DEPARTMENT 701 OCEAN STREET, 4 TH FLOOR, SANTA CRUZ, CA 95060 (831) 4542580 FA: (831) 4542131 STATEMENT OF SPECIAL INSPECTIONS California Building Code 1704.3 Prior to issuance,

More information

Project Address: Name of Person Completing Form:

Project Address: Name of Person Completing Form: Statement of Inspections This form is provided as a way to list aspects of the project that require special inspection and testing in accordance with IBC Sections 107.1, 1704, and 1705 and define duties

More information

SPECIAL INSPECTION AGREEMENT

SPECIAL INSPECTION AGREEMENT PART 1 STATEMENT OF SPECIAL INSPECTIONS When special inspection is required to be performed in accordance with International Building Code Chapter 17, a building permit cannot be issued until a statement

More information

2012 VIRGINIA TECH SCHEDULE OF SPECIAL INSPECTIONS

2012 VIRGINIA TECH SCHEDULE OF SPECIAL INSPECTIONS 2012 VIRGINIA TECH SCHEDULE OF SPECIAL INSPECTIONS HECO-6 GENERAL Pre-construction conference Preconstruction meeting Scheduled by SI with the Contractor, UBO, A/E, and relevant subs prior to commencement

More information

Anchor bolts ASTM F1554, Gr. 36 Wide flange beams ASTM A992, Fy = 50 ksi Misc. structural steel ASTM A36, Fy = 36 ksi

Anchor bolts ASTM F1554, Gr. 36 Wide flange beams ASTM A992, Fy = 50 ksi Misc. structural steel ASTM A36, Fy = 36 ksi STRUCTURAL NOTES MATERIAL STRENGTHS Structural Steel Reinforcing Steel Concrete Masonry Structural Lumber Anchor bolts ASTM F1554, Gr. 36 Wide flange beams ASTM A992, Fy = 50 ksi Misc. structural steel

More information

SPECIAL INSPECTION AND TESTING AGREEMENT

SPECIAL INSPECTION AND TESTING AGREEMENT COUNTY OF MENDOCINO DEPARTMENT OF PLANNING AND BUILDING SERVICES 860 NORTH BUSH STREET UKIAH CALIFORNIA 95482 120 WEST FIR STREET FT. BRAGG CALIFORNIA 95437 STEVE DUNNICLIFF, DIRECTOR PHONE: 707-234-6650

More information

SPECIAL INSPECTION AGREEMENT FORM

SPECIAL INSPECTION AGREEMENT FORM CITY OF TRACY DEVELOPMENT & ENGINEERING SERVICES 333 CIVIC CENTER PLAZA, TRACY, CA 95376 P :( 209) 831-6400 F :( 209) 831-6439 http://www.ci.tracy.ca.us SPECIAL INSPECTION AGREEMENT FORM Prior to issuance

More information

STRUCTURAL STEEL FRAMING

STRUCTURAL STEEL FRAMING SECTION 05 12 00 - STRUCTURAL STEEL FRAMING PART 1 - GENERAL 1.1 SUMMARY A. Section includes 1. Structural steel framing 2. Structural steel framing required for support and framing of rooftop mechanical

More information

EXAMPLE STATEMENT OF SPECIAL INSPECTIONS (SSI)

EXAMPLE STATEMENT OF SPECIAL INSPECTIONS (SSI) EXAMPLE STATEMENT OF SPECIAL INSPECTIONS (SSI) For this example let s consider a single-story retail shell building. The main structural walls consist of CMU construction with the front of the building

More information

Statement of Special Inspections

Statement of Special Inspections Statement of Special Inspections SUCF Project No: Project Title: Registered Design Professionals in Responsible Charge: (Name) (Address) Architect: Structural Engineer: Mechanical Engineer: Identification

More information

SPECIAL INSPECTION AND OBSERVATION PROGRAM City of Walnut Creek Building Division. Project Address:

SPECIAL INSPECTION AND OBSERVATION PROGRAM City of Walnut Creek Building Division. Project Address: SPECIAL INSPECTION AND OBSERVATION PROGRAM City of Walnut Creek Building Division Permit Application #: Project Address: Purpose: To meet the requirements of City of Walnut Creek Municipal Code Section

More information

Building Department Informational Handout

Building Department Informational Handout City of Sonoma Building Department Informational Handout Statement of Special Inspections Handout No: 7 Revised 1/12/2017 Project Name: Project Address: For building permit applications of projects requiring

More information

Report of Special Inspections

Report of Special Inspections Project: Project Location: Report of Special Inspections Central Carolina Technical College Advanced Manufacturing Technology Training Center Sumter, South Carolina Permit Number: Owner/Address: 853 Broad

More information

PROJECT: TULSA COMMUNITY COLLEGE BOOKSTORE RENOVATION PROJECT NUMBER: ISSUE: CONSULTANT: SEAL: SHEET NUMBER: GENERAL NOTES

PROJECT: TULSA COMMUNITY COLLEGE BOOKSTORE RENOVATION PROJECT NUMBER: ISSUE: CONSULTANT: SEAL: SHEET NUMBER: GENERAL NOTES GENERAL NOTES TYPICAL DETAILS REQUIRED VERIFICATION & INSPECTION OF CONCRETE CONSTRUCTION VERIFICATION AND INSPECTION 1. Inspection of reinforcing steel, including prestressing tendons and placement. 2.

More information

SPECIAL INSPECTION AGREEMENT

SPECIAL INSPECTION AGREEMENT DEVELOPMENT SERVICES DEPARTMENT BUILDING AND SAFETY DIVISION 156 S. BROADWAY, SUITE 130 TURLOCK, CALIFORNIA 95380 PHONE 209-668-5560 FAX 209-668-5107 SPECIAL INSPECTION AGREEMENT PERMIT NUMBER: DATE: OWNER:

More information

Jackson Crossing Located in Alexandria, VA. Technical Report 1 Michael Bologna

Jackson Crossing Located in Alexandria, VA. Technical Report 1 Michael Bologna Jackson Crossing Located in Alexandria, VA Technical Report 1 Michael Bologna Structural Option Advisor: Dr. Linda Hanagan September 11, 2015 Table of Contents Executive Summary.3 Introduction 4 Purpose..4

More information

DESIGN STANDARDS WASHINGTON UNIVERSITY SCHOOL OF MEDICINE

DESIGN STANDARDS WASHINGTON UNIVERSITY SCHOOL OF MEDICINE SECTION 01 43 29 (00041) SPECIAL INSPECTIONS PART 1 GUIDELINES As defined by the IBC 2003, Section 1704, Special Inspections of materials, installation, fabrication, erection of components and connections

More information

SPECIAL INSPECTION AND OBSERVATION PROGRAM CITY OF CONCORD BUILDING DIVISION. Project Address:

SPECIAL INSPECTION AND OBSERVATION PROGRAM CITY OF CONCORD BUILDING DIVISION. Project Address: SPECIAL INSPECTION AND OBSERVATION PROGRAM CITY OF CONCORD BUILDING DIVISION Permit Application #: Project Address: Purpose: To meet the requirements of CBC Section 1704.3 this form may be used as a statement

More information

SPECIAL INSPECTION PROGRAM GUIDE

SPECIAL INSPECTION PROGRAM GUIDE CHARTER TOWNSHIP OF WEST BLOOMFIELD BUILDING DEPARTMENT SPECIAL INSPECTION PROGRAM GUIDE 9/5/08 TABLE OF CONTENTS Page No. INTRODUCTION 1 GENERAL GUIDELINES FOR THE SPECIAL INSPECTION PROGRAM.. 2 Purpose

More information

1. Base plates, setting plates and anchor rods for columns. 8. Lintels if connected to structural steel columns.

1. Base plates, setting plates and anchor rods for columns. 8. Lintels if connected to structural steel columns. PAGE 051200-1 SECTION 051200 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification sections,

More information

SECTION MISCELLANEOUS METAL FABRICATIONS

SECTION MISCELLANEOUS METAL FABRICATIONS SECTION 05500 PART I - GENERAL 1.01 DESCRIPTION: A. Scope: Work under this Section shall include all material and installation necessary to provide Miscellaneous Metal Fabrications, as shown and detailed

More information

ANCHOR BOLT ANGLE (AISC) ARCH. A. BOLT LBS. ARCHITECTURAL POUNDS B.O. DOUBLE ANGLE (AISC) BCI BOTTOM OF I-JOIST (BOISE CASCADE) LVL

ANCHOR BOLT ANGLE (AISC) ARCH. A. BOLT LBS. ARCHITECTURAL POUNDS B.O. DOUBLE ANGLE (AISC) BCI BOTTOM OF I-JOIST (BOISE CASCADE) LVL A. BOLT ANCHOR BOLT L ANGLE (AISC) ARCH. ARCHITECTURAL LBS. POUNDS B.O. BOTTOM OF LL DOUBLE ANGLE (AISC) BCI I-JOIST (BOISE CASCADE) LVL LAMINATED VENEER LUMBER BRG. BEARING MAX. MAXIMUM C CHANNEL (AISC)

More information

ANCHOR BOLT ANGLE (AISC) ARCH. A. BOLT LBS. ARCHITECTURAL POUNDS B.O. DOUBLE ANGLE (AISC) BCI BOTTOM OF I-JOIST (BOISE CASCADE) LVL

ANCHOR BOLT ANGLE (AISC) ARCH. A. BOLT LBS. ARCHITECTURAL POUNDS B.O. DOUBLE ANGLE (AISC) BCI BOTTOM OF I-JOIST (BOISE CASCADE) LVL A. BOLT ANCHOR BOLT L ANGLE (AISC) ARCH. ARCHITECTURAL LBS. POUNDS B.O. BOTTOM OF LL DOUBLE ANGLE (AISC) BCI I-JOIST (BOISE CASCADE) LVL LAMINATED VENEER LUMBER BRG. BEARING MAX. MAXIMUM C CHANNEL (AISC)

More information

Mezzanines By Design Page 1

Mezzanines By Design Page 1 SECTION 05120 STRUCTURAL STEEL PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General Conditions and Division 1 apply to this Section. 1.2 SUMMARY

More information

SPECIAL INSPECTIONS AND TESTS

SPECIAL INSPECTIONS AND TESTS CHAPTER 17 SPECIAL INSPECTIONS AND TESTS SECTION 1701 GENERAL 1701.1 Scope. The provisions of this chapter shall govern the quality, workmanship and requirements for materials covered. Materials of construction

More information

SECTION PLATE CONNECTED WOOD TRUSSES

SECTION PLATE CONNECTED WOOD TRUSSES SECTION 06173 PLATE CONNECTED WOOD TRUSSES PART 1 GENERAL 1.01 SUMMARY A. Section Includes: 1. Shop fabricated wood trusses for roof and floor framing. 2. Bridging, bracing, and anchorage. B. Related Sections:

More information

SECTION COLD-FORMED METAL TRUSSES

SECTION COLD-FORMED METAL TRUSSES SECTION 054400 COLD-FORMED METAL TRUSSES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

DIVISION 5 METALS SECTION STRUCTURAL STEEL

DIVISION 5 METALS SECTION STRUCTURAL STEEL DIVISION 5 METALS SECTION 05 12 00 PART 1 GENERAL 1.01 SUMMARY A. Section Includes: All labor and materials required to furnish and install the structural steel shown on the Drawings and required by these

More information

HAMPTON ROADS AREA STATEMENT OF SPECIAL INSPECTIONS

HAMPTON ROADS AREA STATEMENT OF SPECIAL INSPECTIONS Appendix A HAMPTON ROADS AREA STATEMENT OF SPECIAL INSPECTIONS PROJECT PERMIT APPLICANT PRIMARY RDP OF RECORD STRUCTURAL ENGINEER OF RECORD This Statement of Special Inspections is submitted as a condition

More information

INSPECTION GUIDELINES: SPECIAL INSPECTION REQUIREMENTS

INSPECTION GUIDELINES: SPECIAL INSPECTION REQUIREMENTS Special Inspection Requirements Page 1 of 8 Revision Date: 08/07/2018 DEVELOPMENT SERVICES BUILDING INSPECTION INSPECTION GUIDELINES: SPECIAL INSPECTION REQUIREMENTS INSPECTION CODE: N/A SCOPE: RESIDENTIAL

More information

1. Cast-in-place concrete is specified in Section

1. Cast-in-place concrete is specified in Section SECTION 03 38 00 PART 1 - GENERAL 1.01 DESCRIPTION A. This Section describes the requirements for furnishing and installing post-tensioned slabs, jacks, jacking and anchors at Parking Structure, and record

More information

K. ASTM F436- Standard Specification for Hardened Steel Washers; 2011.

K. ASTM F436- Standard Specification for Hardened Steel Washers; 2011. DIVISION 05 METALS 05 12 00 STRUCTURAL STEEL FRAMING PART 1 GENERAL 1.1 SECTION INCLUDES A. Structural steel framing members, support members. 1.2 RELATED REQUIREMENTS A. Section 05 50 00 - Metal Fabrications:

More information

SECTION ANCHOR SYSTEMS

SECTION ANCHOR SYSTEMS SECTION 05 05 00 ANCHOR SYSTEMS PART 1 GENERAL 1.1 SUMMARY A. Section Includes: 1. Anchor bolts. B. Requirement: 1. Furnish all materials, labor and equipment required to provide anchor systems not specifically

More information

STRUCTURAL TESTS AND SPECIAL INSPECTIONS

STRUCTURAL TESTS AND SPECIAL INSPECTIONS CHAPTER 17 STRUCTURAL TESTS AND SPECIAL INSPECTIONS SECTION 1701 GENERAL 1701.1 Scope. The provisions of this chapter shall govern the quality, workmanship and requirements for materials covered. Materials

More information

SECTION STRUCTURAL METAL FRAMING

SECTION STRUCTURAL METAL FRAMING SECTION 05100 STRUCTURAL METAL FRAMING PART 1 GENERAL 1.01 SUMMARY A. Section Includes: Structural steel framing including lintels, shelf angles, bearing plates, anchor bolts and other items as shown on

More information

STATEMENT OF SPECIAL INSPECTIONS - MBC-200 City of Bloomfield Hills Building Department

STATEMENT OF SPECIAL INSPECTIONS - MBC-200 City of Bloomfield Hills Building Department 1 2 STATEMENT OF SPECIAL INSPECTIONS - MBC-200 City of Bloomfield Hills Building Department 3 4 5 6 7 PROJECT INFORMATION: Project Name: Owner Name: Architect/Engineer Name: FORM PREPARED BY: Project Address:

More information

A. Structural Steel: Elements of structural-steel frame, as classified by AISC 303, "Code of Standard Practice for Steel Buildings and Bridges.

A. Structural Steel: Elements of structural-steel frame, as classified by AISC 303, Code of Standard Practice for Steel Buildings and Bridges. SECTION 05 12 00 - STRUCTURAL STEEL FRAMING PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

STATEMENT OF SPECIAL INSPECTIONS - MBC-2012

STATEMENT OF SPECIAL INSPECTIONS - MBC-2012 1 2 STATEMENT OF SPECIAL INSPECTIONS - MBC-2012 CHARTER TOWNSHIP OF WEST BLOOMFIELD BUILDING DEPARTMENT 3 4 5 6 7 8 9 10 11 12 13 PROJECT INFORMATION: Project Name: Owner Name: Architect/Engineer Name:

More information

DECK PERMIT APPLICATION

DECK PERMIT APPLICATION DECK PERMIT APPLICATION APPLICANT S INFORMATION Name: Company Name: Current address: City: State: ZIP Code: Phone: Email: PROPERTY OWNER S INFORMATION Name: Property Address: Phone: E-mail: City: State:

More information

Residential Deck Safety, Construction and Repair. Juneau Permit Center, 4 th Floor Marine View Center,(907) February 2016

Residential Deck Safety, Construction and Repair. Juneau Permit Center, 4 th Floor Marine View Center,(907) February 2016 February 2016 Residential Deck Safety, Construction and Repair Juneau Permit Center, 4 th Floor Marine View Center,(907)586-0770 This handout is designed to help you build your deck to comply with the

More information

C. Delegated-Design Submittal: For metal-plate-connected wood trusses indicated to comply with

C. Delegated-Design Submittal: For metal-plate-connected wood trusses indicated to comply with SECTION 06 17 53 PART1 - GENERAL 1.01 A. SUMMARY Section Includes installation of the following products which have been purchased and delivered to the project site under a separate contract: 1. Wood roof

More information

Statement of Special Inspections

Statement of Special Inspections Statement of Special Inspections Project: Location: Owner: Design Professional in Responsible Charge: This Statement of Special Inspections is submitted as a condition for permit issuance in accordance

More information

GARAGE MAIN FLOOR PLAN

GARAGE MAIN FLOOR PLAN BUILDING CONTRACTOR/HOME OWNER TO REVIEW AND VERIFY ALL DIMENSIONS, SPECS, AND CONNECTIONS BEFORE CONSTRUCTION BEGINS. SHED TO BE BUILT AS PER IRC, UBC OR CURRENT LOCAL CODE To the best of my knowledge

More information

Chapter 2 QUALITY ASSURANCE

Chapter 2 QUALITY ASSURANCE Chapter 2 QUALITY ASSURANCE 2.1 GENERAL 2.1.1 Scope. This chapter provides minimum requirements for quality assurance for seismic-forceresisting systems and designated seismic systems. These requirements

More information

SECTION WOOD FRAMING. A. Includes But Not Limited To 1. Furnish and install wood framing and blocking as described in Contract Documents.

SECTION WOOD FRAMING. A. Includes But Not Limited To 1. Furnish and install wood framing and blocking as described in Contract Documents. SECTION 06110 WOOD FRAMING PART 1 GENERAL 1.1 SUMMARY A. Includes But Not Limited To 1. Furnish and install wood framing and blocking as described in Contract Documents. B. Products Installed But Not Supplied

More information

SECTION STRUCTURAL STEEL

SECTION STRUCTURAL STEEL SECTION 051200 STRUCTURAL STEEL PART 1 GENERAL 1.01 SECTION INCLUDES A. Structural steel framing members and support members. B. Base plates, shear stud connectors. C. Grouting under base plates. 1.02

More information

SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS SECTION 260548 - VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 SUMMARY A. Section includes: 1. Isolation pads. 2. Spring isolators. 3. Restrained spring isolators. 4. Channel

More information

Facility Repairs - MCAS Cherry Point - Tank Farm A SECTION STRUCTURAL STEEL 05/14

Facility Repairs - MCAS Cherry Point - Tank Farm A SECTION STRUCTURAL STEEL 05/14 SECTION 05 12 00 STRUCTURAL STEEL 05/14 PART 1 GENERAL 1.1 REFERENCES The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the

More information

SECTION STRUCTURAL STEEL

SECTION STRUCTURAL STEEL SECTION 05120 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification Sections, apply to this

More information

2016 Port of San Francisco Building Code

2016 Port of San Francisco Building Code PORT CODE PROCEDURE NO. : DATE : December 5, 2012 SUBJECT : Permit Process; Inspection TITLE : Special Inspection and Structural Observation Procedures PURPOSE : The purpose of this Port Code Procedure

More information

Stone and Masonry Veneer

Stone and Masonry Veneer Stone and Masonry Veneer R703.7 Stone and masonry veneer, general. Stone and masonry veneer shall be installed in accordance with this chapter, Table R703.4 and Figure R703.7. These veneers installed over

More information

SPECIAL INSPECTION PROCEDURE IBC CHAPTER 17, 2015 EDITION

SPECIAL INSPECTION PROCEDURE IBC CHAPTER 17, 2015 EDITION SPECIAL INSPECTION PROCEDURE IBC CHAPTER 17, 2015 EDITION When uired All projects that require a SC Licensed Architect or Engineer per SC Architectural and Engineering Registration Law. Overview The program

More information

DIVISION 5 - STRUCTURAL STEEL AND IRON WORK

DIVISION 5 - STRUCTURAL STEEL AND IRON WORK DIVISION 5 - STRUCTURAL STEEL AND IRON WORK SECTION 05100 STRUCTURAL METAL FRAMING PART 1.00 GENERAL 1.01 SCOPE OF WORK A. Work Included: 1. 2. Structural steel complete in place. Steel joists complete

More information

HILLSBOROUGH TOWNSHIP CODE ENFORCEMENT

HILLSBOROUGH TOWNSHIP CODE ENFORCEMENT HILLSBOROUGH TOWNSHIP CODE ENFORCEMENT SAMPLE GUIDE FOR RESIDENTIAL DECKS revised 7 16 Call before you dig! 1 800 272 1000 New Jersey One Call. Utility Mark Out. THIS GENERIC GUIDE IS NOT ALL INCLUSIVE

More information

Typical Deck. CONSTRUCTION TIP SHEET 5 Basic Decks w/ 60 lb Live Loading

Typical Deck. CONSTRUCTION TIP SHEET 5 Basic Decks w/ 60 lb Live Loading CONSTRUCTION TIP SHEET 5 w/ 60 lb Live Loading April 1, 2017 This Tip Sheet reflects code requirements of the 2015 International Residential Code (IRC) with Washington State Amendments which update the

More information

Student Services & Classroom Addition SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

Student Services & Classroom Addition SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS SECTION 26 05 48 - VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 SUMMARY A. Section includes: 1. Isolation pads. 2. Spring isolators. 3. Restrained spring isolators. 4. Channel

More information

SECTION VIBRATION AND SEISMIC CONTROLS FOR HVAC PIPING AND EQUIPMENT

SECTION VIBRATION AND SEISMIC CONTROLS FOR HVAC PIPING AND EQUIPMENT SECTION 230548 - VIBRATION AND SEISMIC CONTROLS FOR HVAC PIPING AND EQUIPMENT PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary

More information

Multi-Institutional Academic Health Science & Research Center Evansville, IN

Multi-Institutional Academic Health Science & Research Center Evansville, IN SECTION 05 5117 ALTERNATING TREAD STEEL STAIRS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification

More information

SECTION METAL FABRICATIONS FOR STEAM UTILITY DISTRIBUTION

SECTION METAL FABRICATIONS FOR STEAM UTILITY DISTRIBUTION PAGE 055015-1 SECTION 055015 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification sections,

More information

DIVISION 5 METALS SECTION METAL DECKING

DIVISION 5 METALS SECTION METAL DECKING DIVISION 5 METALS SECTION 05 30 00 PART 1 GENERAL 1.01 SUMMARY A. Section Includes: All labor and materials required to furnish and install metal decking and accessories including shear connectors, closures,

More information

The designer shall also submit additional information required by the University as described and underlined below.

The designer shall also submit additional information required by the University as described and underlined below. I. Structural Engineering Submissions The designer shall submit all information required by the State Construction Office (SCO) as described in the State Construction Manual Chapter 300 - Project Design

More information

Typical Deck Details Based on the 2009 International Residential Code (Designed and Printed August 2010)

Typical Deck Details Based on the 2009 International Residential Code (Designed and Printed August 2010) 1307 West Lehigh Street Bethlehem, PA 18018 610-866-9663 Office info@keycodes.net www.keycodes.net Typical Deck Details Based on the 2009 International Residential Code (Designed and Printed August 2010)

More information

Typical Deck. CONSTRUCTION TIP SHEET 5 Basic Decks w/ 60 psf Live Loading

Typical Deck. CONSTRUCTION TIP SHEET 5 Basic Decks w/ 60 psf Live Loading CONSTRUCTION TIP SHEET 5 Basic Decks w/ 60 psf Live Loading April 1, 2017 This Tip Sheet reflects code requirements of the 2015 International Residential Code (IRC) with Washington State Amendments which

More information

NORTHWESTERN UNIVERSITY PROJECT NAME JOB #

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # SECTION 26 0529 - HANGERS AND SUPPORTS FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and

More information

STATE UNIVERSITY CONSTRUCTION FUND. UNIVERSITY CON DIRECTIVE 5-1 Issue date: October 2014

STATE UNIVERSITY CONSTRUCTION FUND. UNIVERSITY CON DIRECTIVE 5-1 Issue date: October 2014 STATE STRUCTION FUND DIRECTIVE 5-1 Issue date: October 2014 STRUCTURAL STEEL 1. General: It is the Fund's policy that the design of the structural steel is the prime responsibility of the project's Structural

More information

Owner... Contractor... City/St... Zip... Phone... City/St... Zip... Phone...

Owner... Contractor... City/St... Zip... Phone... City/St... Zip... Phone... COUNTY OF MENDOCINO DEPARTMENT OF PLANNING AND BUILDING SERVICES 860 NORTH BUSH STREET UKIAH CALIFORNIA 95482 120 WEST FIR STREET FORT BRAGG CALIFORNIA 95437 STATEMENT OF SPECIAL INSPECTIONS STEVE DUNNICLIFF,

More information

SECTION METAL STAIRS

SECTION METAL STAIRS SECTION 05 51 00 METAL STAIRS PART 1 GENERAL 1.1 SUMMARY A. Section includes steel stair frame of structural sections, with closed risers; pan to receive concrete fill stair treads and landings; integral

More information

SECTION METAL STAIRS

SECTION METAL STAIRS SECTION 05510 METAL STAIRS PART 1 GENERAL 1.01 SECTION INCLUDES A. Stairs with concrete treads. B. Stairs with metal treads. C. Structural steel stair framing and supports. D. Handrails and guards. 1.02

More information

List of Required Structural Tests & Special Inspections CBC

List of Required Structural Tests & Special Inspections CBC Page 1 of 6 School Name Solana Ranch Elementary School 37-81 IMPORTANT: This form is only a summary list of structural tests and some of the special inspections required for the project. Generally, the

More information

CARROLL COUNTY BUREAU OF PERMITS AND INSPECTIONS RESIDENTIAL CODE COMPLIANCE GUIDELINES FOR DECKS

CARROLL COUNTY BUREAU OF PERMITS AND INSPECTIONS RESIDENTIAL CODE COMPLIANCE GUIDELINES FOR DECKS CARROLL COUNTY BUREAU OF PERMITS AND INSPECTIONS RESIDENTIAL CODE COMPLIANCE GUIDELINES FOR DECKS Code Reference: Chapter 97, Code of Public Local Laws and Ordinances of Carroll County and The International

More information

PROJECT: 4/30/14 DATE: REVISIONS: 6/10/14 7/28/14 11/3/14 11/12/14 11/14/14 OF 6

PROJECT: 4/30/14 DATE: REVISIONS: 6/10/14 7/28/14 11/3/14 11/12/14 11/14/14 OF 6 4/30/14 C 7/31/2014 4'-6" RAMP TO EXISTING GRADE DRAWN: JW 11/12/2014 AS REQ'D 7'-10 1/2" 7'-10 1/2" 7'-10 1/2" 7'-10 1/2" 2'-0 1/2" 4'-10 1/2" 6" 3'-10" 3'-8" L2X2X1/8 @ 16" OC (TYP) L2X2X1/8 @ 16"

More information

REINFORCED CONCRETE MASONRY SECTION

REINFORCED CONCRETE MASONRY SECTION SECTION 04 22 02 - REINFORCED CONCRETE MASONRY PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of Contract, including General and Supplementary Conditions and Division 01 Specification

More information

REQUEST FOR PROPOSAL FOR MATERIAL TESTING AND SPECIAL INSPECTION SERVICES

REQUEST FOR PROPOSAL FOR MATERIAL TESTING AND SPECIAL INSPECTION SERVICES REQUEST FOR PROPOSAL FOR MATERIAL TESTING AND SPECIAL INSPECTION SERVICES DATE: November 13, 2018 PROJECT: OWNER: BUDGET: University Farm Pavilion College of Agriculture and Environmental Services NC A&T

More information

Insulating Cellular Concrete Steel Joists Painting. A. America Society for Testing and Materials (ASTM):

Insulating Cellular Concrete Steel Joists Painting. A. America Society for Testing and Materials (ASTM): SECTION 05120 STRUCTURAL STEEL PART 1 GENERAL 1.01 SUMMARY A. Related Sections: 1. 03342 - Insulating Cellular Concrete. 2. 05210 - Steel Joists. 3. 09900 - Painting. 1.02 REFERENCES A. America Society

More information

1.02 SYSTEM DESCRIPTION

1.02 SYSTEM DESCRIPTION 1 OF 7 MODULAR MEZZANINES GUIDE SPECIFICATIONS FOR PART 1 - GENERAL 1.01 RELATED WORK A. SECTION 03 30 00: Cast in Place Concrete (and Concrete Finishing) 1. The area where mezzanine is installed shall

More information

GARAGE MAIN FLOOR PLAN

GARAGE MAIN FLOOR PLAN 30 year dimensional shingles and Metal Verticle siding over structural sheathing. Nailing schedule is " on ends 12" on centers d nails. Trusses are engineered on 24" and framing is 2" x " on 1" centers.

More information

1.02 SYSTEM DESCRIPTION

1.02 SYSTEM DESCRIPTION 1 OF 7 MODULAR MEZZANINES GUIDE SPECIFICATIONS FOR PART 1 - GENERAL 1.01 RELATED WORK A. SECTION 03 30 00: Cast in Place Concrete (and Concrete Finishing) 1. The area where mezzanine is installed shall

More information

SECTION METAL PLATE CONNECTED WOOD TRUSSES PART 1 - GENERAL 1.01 RELATED DOCUMENTS

SECTION METAL PLATE CONNECTED WOOD TRUSSES PART 1 - GENERAL 1.01 RELATED DOCUMENTS SECTION 06192 - PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification Sections, apply to

More information

SPECIAL INSPECTION REQUIREMENTS - STEEL CONSTRUCTION

SPECIAL INSPECTION REQUIREMENTS - STEEL CONSTRUCTION GENERAL STRUCTURAL NOTES 1. The Contractor shall be responsible for means, methods sequences and procedures of construction. 2. Construction shall comply fully with the applicable provisions of OSHA and

More information

CHAPTER 3 BUILDINGS WITH WOOD FRAMED EXTERIOR WALLS 301 SCOPE

CHAPTER 3 BUILDINGS WITH WOOD FRAMED EXTERIOR WALLS 301 SCOPE CHAPTER 3 BUILDINGS WITH WOOD FRAMED EXTERIOR WALLS WOOD CHAPTER 3 301 SCOPE This chapter prescribes construction requirements for buildings where all exterior walls above the foundation are wood framed

More information

Manufactured decking (composite) may be used when approved by the building department

Manufactured decking (composite) may be used when approved by the building department DO YOU THINK YOU MIGHT ENCLOSE YOUR DECK IN THE FUTURE? Deck plans are approved based on the assumption that the deck will be used only as a deck for the life of the structure. Because there are so many

More information

Trusted ICC ES TEK USA, Evaluation. report, or as to any. ICC-ES Evaluation

Trusted ICC ES TEK USA, Evaluation. report, or as to any. ICC-ES Evaluation 0 ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.orgg Most Widely Accepted and Trusted ESR 3105 Reissued 08/2017 Revised 10/2018 This report is subject to renewal 08/2019.

More information

STRUCTURAL STEEL FRAMING Section

STRUCTURAL STEEL FRAMING Section PART 1 - GENERAL 1.1 SUMMARY A. Section Includes: 1. Structural steel. 2. Grout. 1.2 DEFINITIONS A. Structural Steel: Elements of the structural frame indicated on Drawings and as described in AISC 303,

More information

SPECIFICATIONS Drawing Name: V:\Projects - Current\ J Small Projects - SEHS Womens Locker Room\2. Design\2.5 Design Phase\c. Construction D

SPECIFICATIONS Drawing Name: V:\Projects - Current\ J Small Projects - SEHS Womens Locker Room\2. Design\2.5 Design Phase\c. Construction D SPECIFICATIONS Drawing Name: V:\Projects - Current\17-0715-04 4J Small Projects - SEHS Womens Locker Room\2. Design\2.5 Design Phase\c. Construction Documents\c. Working Drawings\Struc\SEHS WLR Struc Plan.dwg

More information

Home Depot Page 1 of 5 HDPB Humacao, PR 10/19/09

Home Depot Page 1 of 5 HDPB Humacao, PR 10/19/09 PART 1 - GENERAL 1.01 SUMMARY A. Types of cold-formed metal framing units include the following: 1. C-shaped steel studs B. Related work specified elsewhere includes but may not be limited to: 1. Section

More information

Student Services & Classroom Addition

Student Services & Classroom Addition SECTION 055113 - METAL PAN STAIRS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

S001 Structural General Notes and Legend

S001 Structural General Notes and Legend General Notes A. PROJECT INFORMATION. Building Jurisdiction: Summit County, CO. Building Code: IRC 0 B. DESIGN INFORMATION. Load Table: Load e Dead Weight (psf) Dead Load (psf) Superimposed Loads Live

More information

Custom 22' x 40' - 16' Tall Garage Plan #g227 By SDS-CAD Specialized Design Systems

Custom 22' x 40' - 16' Tall Garage Plan #g227 By SDS-CAD Specialized Design Systems P O Box 34 Mendon, Utah Custom 22' x 40' - 16' Tall Garage Plan #g22 By Page 1 Title Page Page 2 Main Floor Plan Page 3 Foundation Plan Page 4 Elevation Views Page 5 Framing and Details Page 6 Typical

More information

SECTION STRUCTURAL STEEL FRAMING

SECTION STRUCTURAL STEEL FRAMING SECTION 05 1200 STRUCTURAL STEEL FRAMING PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

Carroll County Bureau of Permits and Inspection Residential Code Compliance Guidelines Detached Garage

Carroll County Bureau of Permits and Inspection Residential Code Compliance Guidelines Detached Garage Carroll County Bureau of Permits and Inspection Residential Code Compliance Guidelines Detached Garage The following list of code requirements is intended to assist you in complying with the Code of Public

More information

SECTION STRUCTURAL STEEL

SECTION STRUCTURAL STEEL SECTION 05120 PART I - GENERAL 1.01 DESCRIPTION A. Scope: Work under this Section shall include all materials and installation necessary to provide Structural Steel as shown and detailed on the Drawings

More information

TCC/SHORE TRANSIT BUS MAINTENANCE FACILITY - PHASE II

TCC/SHORE TRANSIT BUS MAINTENANCE FACILITY - PHASE II SECTION 052100 - STEEL JOISTS PART 1 - GENERAL 1.1 RELATED DOCUMENTS: A. Drawings and General Provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification Sections

More information

Commission No Section

Commission No Section Commission No. 1511 Section 05120-1 PART ONE - GENERAL 1.1 DESCRIPTION A. Work Included: Structural steel and grout. Furnish, fabricate, mark for erection identification, pack, crate, or otherwise properly

More information

SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions, apply to this Section. 1.2 SUMMARY A. This Section includes the

More information