1 PART L1A GUIDE ENGLAND & WALES MAY 2006 High performance insulation for new mixed development housing Building Regulations Part L1A (2006) COST EFFECTIVE THERMAL SOLUTIONS House Type A House Type B House Type D Semi detached 93m 2 TER Apartment (top) 59m 2 TER Detached 160m 2 TER House Type C Semi detached 96m 2 TER Efficient fabric insulation - Lower energy demands

2 Approved Document L1A Where do we start? Reduce the Energy Demand by providing cost effective energy efficient Thin-R Choosing the right insulation for your project is a vital step when building dwellings to the new Part L1A regulations which will result in energy efficient, comfortable dwellings. This guide provides the solutions to meet the more stringent requirements of the Building Regulations using Xtratherm Thin-R high performance insulation, providing lower U-values in walls, floors and roofs without changing traditional build methods. Rigid Thermal Insulation Further comprehensive information on regulation changes is available in a series of technical briefing notes available from Xtratherm, contact Technical Support for copies. 02

3 Save Energy Save Money Save Space Thin-R The amended Building Regulations Part L1A for New Dwellings came into force on the 6th April Submissions to Building Control from that date need to comply - the requirements are proving more complex than any previous amendments. fabric insulation The revision aims to cut CO 2 emissions in dwellings by around 20% on the previous Part L 2002, and allow for the introduction of the EPBD (Energy Performance of Buildings Directive - Energy Labelling). The directive only allows for a wholebuilding approach based on carbon dioxide emissions, setting an overall Energy Performance target for new houses. This approach allows greater flexibility in the design but with that flexibility, the complexity of available solutions leaves the design vulnerable to failure. The Elemental approach to compliance is no longer available, a greater understanding of the principals of insulation in energy conservation is required in the context of the whole building approach. The starting point for reducing emissions is to provide a well insulated building fabric - this reduces the energy requirements and therefore CO 2 emissions. Whilst other energy saving measures, such as efficient glazing, boilers and renewables will have to be replaced eventually (with perhaps less efficient alternatives) the insulation will deliver energy savings throughout the life of the building. Mixed development sites in England and Wales typically involve a number of house types, each with individual characteristics. We have taken this into consideration when formulating our specifications for the house types illustrated. Standardising thickness requirements for the insulation on a site is important. In the following examples we have achieved compliance using indicative values for all elements, allowing consistency in material specification for all house types thus reducing wastage and potential errors. Improving the air tightness of a design will improve the energy performance, and as experience and good practice develops in relation to air permeability, it might be relied upon to play a more significant part of the energy efficient design. However, because of the uncertainties at present, using the default value of 10 air changes per hour at design stage builds in a Margin of error should a better performance be measured on site. Relying on a more ambitious figure could lead to expensive remedial work having to be completed if the site test differs from an ambitious design calculation figure. Using the Xtratherm default values shown, and allowing for realistic air permeability with cost effective improvements to boiler efficiency and heating controls, the Xtratherm house types illustrated achieve compliance in an efficient, practical and cost effective manner. XTRATHERM DEFAULT VALUES U-VALUE W/m 2 K Floors 0.22 Walls 0.27 Roof - Slope 0.20 Roof -Ceiling

4 CO 2 targets The 20% goal Compliance with Part L1A is dependent on achieving a CO 2 target emission rate lower than that of a Notional Building of the same size and shape as the designed building, using standardised energy performance, conditions of occupancy and weather conditions. Xtratherm Warm-R Eco-House Standard The goal for the designer or the developer is to improve the energy efficiency of the notional building and thus cut the CO 2 emissions by 20% - this new CO 2 emissions figure becomes the Target Emissions Rate (TER). The actual specification of the house being designed or built will provide the Dwellings Emissions Rate (DER), and should reflect the actual house as built taking into account any changes to the design that has been made during construction and the actual measured air permeability. For compehensive guidance on energy efficient design see the Xtratherm Warm-R Guide to building your own home. This final calculation should be submitted to Building Control upon completion. If the DER is below the TER the building will comply with the 1st Criteria (see opposite). Steps to Energy Efficiency and achieving the 20% Consideration should be given to the following inputs when seeking to provide energy efficient designs and thereby reducing CO 2 emissions: Increased fabric insulation with reduced thermal bridging. Improved air-tightness. Controlled ventilation. Efficient heating and hot water systems. Responsive heating and lighting controls. Efficient lighting and fittings that do not permit the use of non-efficient lighting. Input from Low and Zero Carbon Technologies. (See renewable section) An inexhaustible combination of energy efficient measures are available to the specification builder/designer to meet the new Part L Regulations. However, re-arranging these combinations on a site of different house types with different energy requirements, will lead to confusion and costly errors being made. Showing compliance with an over-ambitious design might result in failure when finished measurements taken are less robust than planned for, leading to expensive remedial costs. A builder/designer should aim to achieve an effective building fabric first - lowering the energy target required - then look at how that energy is supplied 04 FOR TECHNICAL SUPPORT CALL

5 Save Energy Save Money Save Space Thin-R 5 criteria to compliance For new dwellings, Approved Document L1A presents five criteria for demonstrating compliance with the new regulations. 1 Calculate CO 2 emissions for the proposed building (using SAP 2005). The Dwelling Carbon Dioxide Emissions Rate (DER, kg/m 2 /yr) must not exceed a Target Carbon Dioxide Emissions Rate (TER, kg/m 2 /yr). 2 Keep within Design limits. Limits for the building fabric and services must not exceed limits set within the document L1A. In reality, building fabric and services with significantly better performance than these design limits will be required to meet the carbon dioxide emissions target. Building fabric - maximum thermal transmittances (U values) for wall, floors & roofs. Approved robust details must be used (see right). Air permeability of the building fabric must not exceed 10 m 3 /m 2 hr, in a 50 Pa pressure test. Minimum efficiencies for heating appliances, minimum controls, and minimum insulation for primary pipework, warm air ducts and hot water storage cylinders. Ventilation equipment, there are design limits expressed in terms of worst acceptable specific fan-power and heat recovery efficiency. Fixed internal lighting must include at least one fitting that will accept only energy efficient lamps (efficacy > 40 lm/w) per 25 m 2 of floorspace or per four fixed lighting outlets (whichever is the greater). Fixed external lighting must either have controls that switch off the lamps (maximum 150 W/lamp) when there is sufficient daylight and when lighting is not required at night, or must use fittings that accept only energy efficient lamps. As well as achieving Target U-values, the revision has placed great emphasis on the Continuity of Insulation in the form of Robust Detailing. The building fabric should be constructed so that there are no reasonably avoidable thermal bridges in the insulation layers, caused by gaps within the various elements, at joints between elements and at the edges of elements such as window and doors surrounds. Details in the publication Limiting thermal bridging and air leakage: robust construction details for dwellings and similar buildings should be followed, or details should be measured to BRE IP1/06. 3 Limit Solar Gains in Summer (Over Heating) There must not be a high risk of the dwelling overheating in warm summer weather. This is demonstrated by a calculation included in the SAP 2005 energy rating calculation, which grades the risk of summer overheating. Designs with High risk do not meet the requirement. A heavy weight (Thermal Mass) building using brick/block is less likely to over heat and is easier to control. 4 Check Quality of Construction and commissioning of building services. There must be no significant thermal bridges. Accredited Robust Construction Details should be used and recorded on site. Pressure tests to establish the tested air permeability must be completed, and actual results used in a revised and final SAP submitted to Building Control. 5 Provide Information to the home owner or occupants of dwellings with operating and maintenance instructions for the building services (heating and hot water systems, and any ventilation or air conditioning systems), to allow for energy efficient operation of the building. See for installation animations 05

6 House Type A (TER 21.17) Detached house 160m 2 TER DER Results shown are specific to the house designs illustrated. There is an inexhaustible combination of energy efficient measures available to the specification builder/designer to meet the new Part L Regulations. Individual designs must be analysed and appraised on practicality of build and cost considerations. All U-values calculations must be calculated in accordance with BR443 Conventions for U-value Calculation SPECIFICATION U-VALUE W/m 2 K Floors 0.22 Walls 0.27 Roof - Slope 0.20 Roof -Ceiling 0.14 Glazing Performance 2.0 Other Inputs Air Changes/Hr 10 Boiler Efficiency 93% VALUE DER kg/m 2 /yr SAP Rating 81 CO 2 IMPROVEMENT 21% Secondary Heating Heating Controls Robust Detailing None Specified Separate time & temp zones 0.08 (Default) AN ALTERNATIVE OPTION FOR REACHING TER WITH INSULATION AS SPECIFIED VALUE VALUE Reduce Boiler efficiency 87% Improve Air Permeability ac/hr 8 Improve Glazing Performance 1.8 New DER New SAP Rating 81 CO 2 Improvement 21% DETACHED DWELLING - House Type A, 160m 2 06 FOR TECHNICAL SUPPORT CALL

7 Thin-R Detached House 160m 2 Specification SLOPE ROOF INSULATION (Xtratherm Pitched Roof) Hybrid roof using a vapour permeable underlay with 25mm void under. Rafters at 600mm c/s. Xtratherm PR 100mm XT/PR100 Between Rafters Xtratherm PR 25mm XT/PR25 Below Rafters 0.20 W/m 2 K WALL INSULATION (Xtratherm Cavity Wall) Partial Fill Cavity Wall - light weight block with dot & dab plasterboard internal finish. Xtratherm CW 50mm XT/CWTG W/m 2 K FLOOR INSULATION (Xtratherm Under Floor) Suspended ground floor P/A 0.58 Xtratherm UF 75mm XT/UF W/m 2 K NOTE 75mm of insulation thickness is optimum for this floor type. No requirement for brickwork coursing to be adjusted. See for installation animations 07

8 House Type B (TER 22.59) Semi-detached house 93m 2 TER DER Results shown are specific to the house designs illustrated. There is an inexhaustible combination of energy efficient measures available to the specification builder/designer to meet the new Part L Regulations. Individual designs must be analysed and appraised on practicality of build and cost considerations. All U-values calculations must be calculated in accordance with BR443 Conventions for U-value Calculation. SPECIFICATION U-VALUE W/m2K Floors 0.22 Walls 0.27 Roof -Ceiling 0.14 Glazing Performance 2.0 VALUE DER kg/m 2 /yr SAP Rating 82 CO 2 IMPROVEMENT 20% Other Inputs Air Changes/Hr 10 Boiler Efficiency 93% Secondary Heating Heating Controls Robust Detailing None Specified Separate time & temp zones 0.08 (Default) AN ALTERNATIVE OPTION FOR REACHING TER WITH INSULATION AS SPECIFIED VALUE VALUE Reduce Boiler efficiency 90% Improve Glazing Performance 1.8 New DER New SAP Rating 82 CO 2 Improvement 20% SEMI-DETACHED DWELLING - House Type B, 93m 2 08 FOR TECHNICAL SUPPORT CALL

9 Save Energy Save Money Save Space Thin-R Semi-detached house 93m 2 Specification ROOF INSULATION (Ceiling Fibre) 2 Layers Fibre insulation 100mm between joists and 200mm over. Fibre 100mm Between Joists Fibre 200mm Over Joists 0.14 W/m 2 K Placing fibre glass between AND over the joists hides the top of the joist and may lead to health and safety concerns when the roof space is being accessed. Placing a layer of Xtratherm to the underside of the joist before the plasterboard is fixed. allows for the roof space to be accessed in a safe manner - leaving the top of the joists exposed, allowing the roof space to be used for storage. WALL INSULATION (Xtratherm Cavity Wall) Partial Fill Cavity Wall - Dense Block with dot & dab plasterboard finish internal finish. Xtratherm CWTG 60mm XT/CWTG W/m 2 K FLOOR INSULATION (Xtratherm Under Floor) Suspended ground floor P/A 0.58 Xtratherm UF 75mm XT/UF W/m 2 K NOTE 75mm of insulation thickness is optimum for this floor type. No requirement for brickwork coursing having to be adjusted. See for installation animations 09

10 House Type C (TER 21.62) Mid-terrace house 96m 2 TER DER Results shown are specific to the house designs illustrated. There is an inexhaustible combination of energy efficient measures available to the specification builder/designer to meet the new Part L Regulations. Individual designs must be analysed and appraised on practicality of build and cost considerations. All U-values calculations must be calculated in accordance with BR443 Conventions for U-value Calculation SPECIFICATION U-VALUE W/m2K Floors 0.20 Walls 0.27 Roof - Slope 0.20 Glazing Performance 2.0 VALUE DER kg/m 2 /yr SAP Rating 83 CO 2 IMPROVEMENT 20% Other Inputs Air Changes/Hr 10 Boiler Efficiency 93% Secondary Heating Heating Controls Robust Detailing None Specified Separate time & temp zones 0.08 (Default) AN ALTERNATIVE OPTION FOR REACHING TER WITH INSULATION AS SPECIFIED VALUE VALUE Reduce Boiler efficiency 87% Improve Glazing Performance 1.5 New DER New SAP Rating 83 CO 2 Improvement 20% MID-TERRACE DWELLING - House Type C, 96m 2 10 FOR TECHNICAL SUPPORT CALL

11 Thin-R Mid-terrace House 96m 2 Specification ROOF INSULATION (Sloped Pitched Roof) Hybrid roof using a vapour permeable underlay with 25mm void under. Rafters at 600mm c/s Xtratherm PR 100mm XT/PR100 Between Rafters Xtratherm PR 25mm XT/PR25 Below Rafters 0.20 W/m 2 K WALL INSULATION (Xtratherm Cavity Wall) Partial Fill Cavity Wall - Dense Block with dot & dab plasterboard finish internal finish. Xtratherm CWTG 60mm XT/CWTG W/m 2 K FLOOR INSULATION (Xtratherm Under Floor) Solid ground floor P/A 0.25 Xtratherm UF 75mm XT/UF W/m 2 K NOTE 75mm of insulation thickness is optimum for this floor type. Increase of thickness will result in brickwork coursing to be adjusted. See for installation animations 11

12 House Type D (TER 25.44) Apartment top floor 59m 2 TER DER Results shown are specific to the house designs illustrated. There is an inexhaustible combination of energy efficient measures available to the specification builder/designer to meet the new Part L Regulations. Individual designs must be analysed and appraised on practicality of build and cost considerations. All U-values calculations must be calculated in accordance with BR443 Conventions for U-value Calculation. SPECIFICATION U-VALUE W/m2K Floors 0.22 Walls 0.27 Roof - Ceiling 0.14 Glazing Performance 2.0 VALUE DER kg/m 2 /yr SAP Rating 83 CO 2 IMPROVEMENT 20% Other Inputs Air Changes/Hr 10 Boiler Efficiency 93% Secondary Heating Heating Controls Robust Detailing None Specified Separate time & temp zones 0.08 (Default) AN ALTERNATIVE OPTION FOR REACHING TER WITH INSULATION AS SPECIFIED VALUE VALUE Reduce Boiler efficiency 87% Improve Air Tightness 6 ac/hr New DER New SAP Rating 83 CO 2 Improvement 20% TOP FLOOR APARTMENT - House Type D, 59m 2 12 FOR TECHNICAL SUPPORT CALL

13 Thin-R Apartment Top Floor 59m 2 Specification ROOF INSULATION (Ceiling Fibre) 2 Layers Fibre insulation 100mm between joists and 200mm over Fibre 100mm Between Joists Fibre 200mm Over Joists 0.14 W/m 2 K Placing fibre glass between AND over the joists hides the top of the joist and may lead to health and safety concerns when the roof space is being accessed. Placing a layer of Xtratherm to the underside of the joist before the plasterboard is fixed. allows for the roof space to be accessed in a safe manner - leaving the top of the joists exposed, allowing the roof space to be used for storage. WALL INSULATION (Xtratherm Cavity Wall) Partial Fill Cavity Wall - Dense Block with dot & dab plasterboard finish internal finish. Xtratherm CWTG 60mm XT/CWTG W/m 2 K FLOOR INSULATION Floor is not included in this calculation as it divides two heated areas, and does not require insulation unless underfloor heating is being used. See for installation animations 13

14 Summary U-value calculations to BS EN ISO:6946 For Technical Support call The combinations available to the designer/builder to achieve the required Target Emissions Rate (TER) are inexhaustable. The specifications for the house types shown, are practical, cost effective solutions that can be relied upon - well insulated building fabric, with efficient boilers and controls. Maintaining consistency in fabric materials simplifies purchase of materials on site for all house types. Using fabric U-values less than those indicated may necessitate the inclusion of more costly technologies and better than normal site practice from sub-contractors to improve air permeability. The goal of achieving best practice in air-tightness should be strived for, but not depended on at this stage to achieve compliance. Detailing in accordance with the Xtratherm Guide to Robust Detailing and the BSRIA Paper 11/ should be consulted. House Type A TER DER Walls Floors Roof SPECIFICATION 50mm Xtratherm 75mm Xtratherm 100/25mm Xtratherm House Type B TER DER Walls Floors Roof SPECIFICATION 60mm Xtratherm 75mm Xtratherm 300mm Fibre* House Type C TER DER Walls Floors Roof SPECIFICATION 60mm Xtratherm 75mm Xtratherm 100/25mm Xtratherm House Type D TER DER Walls Floors Roof SPECIFICATION 60mm Xtratherm N/A 300mm Fibre* 14 *Placing fibre glass between AND over the joists hides the top of the joist and may lead to health and safety concerns when the roof space is being accessed. Placing a layer of Xtratherm to the underside of the joist before the plasterboard is fixed allows for the roof space to be accessed in a safe manner - leaving the top of the joists exposed, allowing the roof space to be used for storage.

15 Save Energy Save Money Save Space Thin-R FAQs When did the revised Part L come into effect? The Part L Revision came into effect on April 6th all plans submitted to Building Control for approval from that date need to meet the new standards. What is the TER & the DER? The TER is the TARGET (CO 2 ) EMISSIONS RATE and is the maximum permitable amount of CO 2 that your design is permitted to create when built. The DER is the ACTUAL (CO 2 ) EMISSIONS RATE of the design. Both the TER & the DER are calculated by SAP 2005, and both are required for building control approval. Can I use the worst allowable U-values quoted in the Part L Document? Much better U-values than 0.35 W/m 2 K for Walls and 0.25 W/m 2 K for floors and roofs can be achieved within traditional contruction methods by simply substituting inefficient insulation materials with Xtratherm PIR. Many traditional insulations will just achieve the worst case U-values - resulting in a lesser performing fabric AND will have to be compensated for by other less cost effective measures. What is Robust Detailing? The Part L Revision places great emphasis on Continuity of Insulation and states that all thermal bridging, or breaks in the insulation layer, be accounted for in the calculations. Xtratherm Insulation Systems, that include Tongued & Grooved wall insulation (T&G jointing is recommended as best practice by the EST) and Floor Perimeter Insulation, have undergone testing by the University of Caledonia and have been found to perform favourably over the default figures given in SAP 2005 for vulnerable junctions. Using Xtratherm Robust Details will ensure an improvement in the SAP Calculation (See the Xtratherm Technical Briefing Note: Xtratherm s Guide to Robust Detailing). What Air Permeability should I design for? Improving the air tightness of a design will improve the energy performance, and as experience and good practice develops in relation to air permeability, it might be relied upon to play a more significant part of the energy efficient design. However, because continuity of site practice cannot be relied upon (variation in teams of sub-contractors and house types for example), using the default value of 10 air changes per hour at design stage builds in a Margin of error should a better performance happen to be measured on site. Relying on a more ambitious figure could lead to expensive remedial work having to be completed if the site test differs from an ambitious design calculation figure. Should I provide insulation at ceiling level - or insulate the rafter slope? Indicative values of 0.14 W/m 2 K have been suggested by many manufacturers as being the required insulation target at ceiling level. This will typically require 300mm of fibrous material to be laid between and OVER the joists, leading to health and safety difficulties when accessing the loft area and necessitate the compression of the fibre at the eaves to allow for ventilation, which leads to thermal bridging and increased condensation risk. Insulating the roof area at the rafter line has the advantage of freeing up the roof area to be used for storage or indeed valuable living space. Why Partial Fill cavity wall insulation? The main goal for the Part L Revision is to reduce the CO 2 pollution caused by new buildings in the UK. These emissions are leading directly to Global Warming, a consequence of which is heavier, more persistent wind driven rain becoming more common in our weather patterns. The most effective protection from wind driven rain is maintaining an air space between the inside of buildings and the outer skin. Xtratherm Partial Fill Cavity insulation has tongued and grooved edges to provide the Robust Jointing specifically asked for under Part L. The advantage of being able to inspect the insulation as it is being built into the building fabric offers reassurance that this continuity is achieved, and indeed enhanced when used as a system with the preformed corner and reveal panels that are provided by Xtratherm. Why 75mm Xtratherm in the floors? Xtratherm Thin-R provides the most efficient means of insulating a floor to the new 2006 standards. Typical floors in the UK have a Perimeter/Area ratio of between 0.4 and mm of Xtratherm will achieve a U-value of between 0.20 and 0.22 W/m 2 K in this range achieving the higher standards within traditional build practices and tie in with brick coursing. Should my design include renewable technologies? Using Low and Zero Carbon Technologies is beneficial in cutting the amount of CO 2 produced by the building, but should be considered only once that energy requirement has been minimised through good design; ie; a well insulated fabric that utilises solar gains and thermal mass to make use of the natural resources (Solar Gains) that are already available to all homes. A well insulated building fabric will last for the life of the building, most other technologies, including glazing, will have to be replaced in a relatively short period of time. Guidance on such systems can be found in the ODPM publication Low or Zero Carbon Energy Sources: Strategic Guide. Will all houses on a site have to be pressure tested? Building Control may ask for one dwelling of each house type to be pressure tested upon completion. If the development is less than 2 dwellings, a default figure of 15 ac/hr can be used when calculating the DER, or if the developer has tested a similar house type in the past 12 months, that test result can be used. Further comprehensive guidance on the new building regulations and best practice advice can be downloaded from the website: 15

16 The Xtratherm range of high performance insulation boards provides the complete solution for newbuild and refurbishment. Thin-R/PR Pitched Roof Effective insulation of roof area Reduced insulation thickness Reduces thermal bridging Minimizes intrusion into living area Suitable for insulating: Ventilated Pitched Roof Warm Pitched Roof Hybrid Pitched Roof Thin-R/TP Flat Roof Insulation & decking in one fix For new & refurbishment roofs Easy to handle & install Rapid weather proofing Suitable for insulating: New Flat Roof Refurbished Flat Roof Thermal Decking Thin-R/CW Cavity Wall Robust tongue & groove jointing Clear cavity maintained No exposure restrictions Low emissivity foil facings Extra thermal performance Suitable for insulating: Partial Fill Cavity Walls Thin-R/TL Thermal Lining High thermal performance Drylining & insulation in one fix Shorter drying time Responsive insulation system Suitable for insulating: Masonry Walls Sloped Rafters Ceilings Thin-R/UF Under Floor Extra thermal performance Suitable for under floor heating Reduced insulation thickness High compressive strength Suitable for insulating: Solid Block Floor Under Screed Floor Suspended Timber Floor Technical Support The Xtratherm Technical Support team provide a single point of contact to offer assistance on a wide range of issues for both the Designer and Builder and can be contacted by phone, fax or . Full details of all Xtratherm products, along with full technical literature can be downloaded from the web site at: Good workmanship and appropriate site procedures are necessary to achieve expected thermal and airtightness performance. The example calculations are indicative only. Default values for components and cavities have been used, for specific U-value calculations contact Xtratherm Technical Support. Comprehensive guidance on installation should be consulted. Xtratherm technical literature and Agrèment certification is available for download on the Xtratherm website. The information contained in this publication is, to the best of our knowledge, true and accurate but any recommendations or suggestions which may be made are without guarantee since the conditions of use are beyond our control. Zero O D P Zero Ozone Depletion Potential Xtratherm UK Limited Park Road Holmewood Chesterfield Derbyshire S42 5UY Tel: Fax: info@xtratherm.com

PIR Insulation. XT/PR Insulation for Pitched Roofs. Roofs 08/ /0183

PIR Insulation. XT/PR Insulation for Pitched Roofs. Roofs 08/ /0183 PIR Insulation Roofs XT/PR Insulation for Pitched Roofs 08/4613 03/0183 Data Sheet XT/PR Insulation for Pitched Roofs Thin-R Pitched Roof XT/PR on sloped roofs (ventilated, hybrid or warm) provides the

More information

The Fabric Energy Efficiency Standard

The Fabric Energy Efficiency Standard Nov 2011 More than insulation. The Fabric Energy Efficiency Standard N Ireland Part F Regulations and the higher levels of the Code for Sustainable Homes Affordable Engineered Solutions to Low Energy Design

More information

Insulation you can trust

Insulation you can trust Insulation you can trust Thin-R Guide Rigid Thermal Insulation More than insulation. Choosing the right insulation for your project is a vital step in creating a building which is comfortable, energy efficient

More information

Superior Performance Phenolic Insulation SR/PR. Insulation for Pitched Roofs. Roofs AS LOW AS 10/4803

Superior Performance Phenolic Insulation SR/PR. Insulation for Pitched Roofs. Roofs AS LOW AS 10/4803 Superior Performance Phenolic Insulation Roofs SR/PR Insulation for Pitched Roofs AS LOW AS 020 10/4803 Data Sheet SR/PR Insulation for Pitched Roofs Safe-R is a superior performance phenolic insulation

More information

The Building Regulations, Part L (2013)

The Building Regulations, Part L (2013) Latest Release November 2013 Technical Briefing Note The Building Regulations, Part L (2013) www.xtratherm.com Technical Briefing Note The Building Regulations, Part L (2013) The latest revisions to energy

More information

Insulation for: Walls. Floors. Roofs. UK Product. Soffit. Handbook. Expect More Choice

Insulation for: Walls. Floors. Roofs. UK Product. Soffit. Handbook. Expect More Choice : Walls Floors UK Product Handbook Roofs Soffit Expect More Choice 2 Introduction For over 30 years Xtratherm has led the way in developing innovative thermal solutions, through advancement in product

More information

One Size Fits All. Insulation A GUIDE TO BUILDING REGULATIONS / STANDARDS COMPLIANCE FOR NEW DWELLINGS USING STRUCTURAL INSULATED PANELS (SIPS)

One Size Fits All. Insulation A GUIDE TO BUILDING REGULATIONS / STANDARDS COMPLIANCE FOR NEW DWELLINGS USING STRUCTURAL INSULATED PANELS (SIPS) Insulation Second Issue April 2018 One Size Fits All A GUIDE TO BUILDING REGULATIONS / STANDARDS COMPLIANCE FOR NEW DWELLINGS USING STRUCTURAL INSULATED PANELS (SIPS) Low Energy Low Carbon Buildings 2

More information

Approved Document L1A and L2A

Approved Document L1A and L2A Guide to: Approved Document L1A and L2A For England and Wales NEWBUILD Conservation of fuel and power APPROVED DOCUMENTL1A Conservation of fuel and power APPROVED DOCUMENTL2A Talk to the SIG360 team at

More information

PIR Insulation XT/TL-MF. Insulation for Drylining Walls (Mechanically Fixed) Walls 04/ /0183

PIR Insulation XT/TL-MF. Insulation for Drylining Walls (Mechanically Fixed) Walls 04/ /0183 PIR Insulation Walls XT/TL-MF Insulation for Drylining Walls (Mechanically Fixed) 04/4130 03/0183 Data Sheet Thin-R Thermal Liner Mechanically Fixed XT/TL-MF is a composite insulated panel of Xtratherm

More information

SAP Calculations. Acheson Construction. Project: Plot 8, Neils View Maiden Newton. Contact: James Frampton Trinity Architecture

SAP Calculations. Acheson Construction. Project: Plot 8, Neils View Maiden Newton. Contact: James Frampton Trinity Architecture SAP Calculations Client: Acheson Construction Project: Plot 8, Neils View Maiden Newton Contact: James Frampton Trinity Architecture james@trinarch.com CODE FOR SUSTAINABLE HOMES - CfSH November 2010 Page

More information

Superior Performance PIR Insulation. XO/PR Insulation for Pitched Roof. Roofs 12/4956

Superior Performance PIR Insulation. XO/PR Insulation for Pitched Roof. Roofs 12/4956 Superior Performance PIR Insulation Roofs XO/PR Insulation for Pitched Roof 021 12/4956 Data Sheet XtroLiner Pitched Roof XO/PR on sloped roofs (ventilated, hybrid or warm) provides the most efficient

More information

Superior Performance PIR Insulation. Roofs. XO/SK (T&G) Insulation for Sarking Warm Roof Construction

Superior Performance PIR Insulation. Roofs. XO/SK (T&G) Insulation for Sarking Warm Roof Construction Superior Performance PIR Insulation Roofs XO/SK (T&G) Insulation for Sarking Warm Roof Construction 021 Data Sheet XO/SK (T&G) Insulation for Sarking Warm Roof Construction XtroLiner Sarking XO/SK is an

More information

Superior Performance Phenolic Insulation SR/TB. Insulation for Drylining Walls Fixed with Adhesive Dabs. Walls AS LOW AS

Superior Performance Phenolic Insulation SR/TB. Insulation for Drylining Walls Fixed with Adhesive Dabs. Walls AS LOW AS Superior Performance Phenolic Insulation Walls SR/TB Insulation for Drylining Walls Fixed with Adhesive Dabs AS LOW AS 020 Data Sheet SR/TB is a composite insulated panel of Xtratherm phenolic insulation

More information

PIR Insulation. XT/UF Insulation for Ground Supported and Suspended Floors. Floors 08/ /0183

PIR Insulation. XT/UF Insulation for Ground Supported and Suspended Floors. Floors 08/ /0183 PIR Insulation Floors XT/UF Insulation for Ground Supported and Suspended Floors 08/4613 03/0183 Data Sheet The floor in any building is an area of considerable downward heat loss when not properly insulated.

More information

PIR Insulation. XT/Walk-R. Insulated Loft Decking. Roofs

PIR Insulation. XT/Walk-R. Insulated Loft Decking. Roofs PIR Insulation Roofs XT/Walk-R Insulated Loft Decking Data Sheet XT/Walk-R Insulated Loft decking Thin-R Loft Decking XT/Walk-R is a composite of high performance PIR insulation with tough OSB board that

More information

A Handbook of thermal bridging details incorporating aircrete blocks

A Handbook of thermal bridging details incorporating aircrete blocks A Handbook of thermal bridging details incorporating aircrete blocks Book 1 Thermal bridging solutions for external wall partial fill cavity details and full fill party wall details Prepared for the Aircrete

More information

PIR Insulation XT/TF. Insulation for Timber Framed Walls. Walls 08/ /0183

PIR Insulation XT/TF. Insulation for Timber Framed Walls. Walls 08/ /0183 PIR Insulation Walls XT/TF Insulation for Timber Framed Walls 08/4613 03/0183 Data Sheet XT/TF Insulation for Timber Framed Walls Timber Frame construction is a fast, systematic method that results in

More information

PIR Insulation XT/TL. Insulation for Drylining Walls Fixed with Adhesive Dabs. Walls 04/ /0183

PIR Insulation XT/TL. Insulation for Drylining Walls Fixed with Adhesive Dabs. Walls 04/ /0183 PIR Insulation Walls XT/TL Insulation for Drylining Walls Fixed with Adhesive Dabs 04/4130 03/0183 Data Sheet XT/TL Insulation for Drylining walls Fixed with Adhesive Dabs Thin-R Thermal Liner Dot & Dab

More information

d1b standard construction drawings new build aerated PART fill 6 digit product code unique to Travis Perkins Group

d1b standard construction drawings new build aerated PART fill 6 digit product code unique to Travis Perkins Group new build standard construction drawings d1b aerated PART fill 6 digit product code unique to Travis Perkins Group 1 Welcome to Sustainable Building Solutions (SBS) is a specialist division of the Travis

More information

PIR Insulation XT/CW (T&G) Insulation for Partial Fill Cavity Walls. Walls 08/ /0183

PIR Insulation XT/CW (T&G) Insulation for Partial Fill Cavity Walls. Walls 08/ /0183 PIR Insulation Walls XT/CW (T&G) Insulation for Partial Fill Cavity Walls 08/4613 03/0183 Data Sheet XT/CW (T&G) Insulation for Partial Fill Cavity Walls Thin-R Partial Fill Cavity Wall XT/CW (T&G) builds

More information

Superior Performance PIR Insulation. XO/FB Insulaton for Steel & Timber Frame. Walls 12/4956

Superior Performance PIR Insulation. XO/FB Insulaton for Steel & Timber Frame. Walls 12/4956 Superior Performance PIR Insulation Walls Insulaton for Steel & Timber Frame 021 12/4956 Data Sheet XtroLiner Framing Board is designed for use in a wide range of construction including steel or timber

More information

Project name SOLAR HOUSE 80/50 Project summary

Project name SOLAR HOUSE 80/50 Project summary http://lowenergybuildings.org.uk Project name SOLAR HOUSE 80/50 Project summary Project Description Projected build start date 01 Mar 2010 Projected date of occupation 19 Jul 2010 Project stage Under construction

More information

Superior Performance PIR Insulation XO/FB. Insulaton for Steel & Timber Frame. Walls 12/4956

Superior Performance PIR Insulation XO/FB. Insulaton for Steel & Timber Frame. Walls 12/4956 Superior Performance PIR Insulation Walls Insulaton for Steel & Timber Frame 021 12/4956 Data Sheet XtroLiner is a superior performance insulation with a lambda value of 0.021 Wm/K and a Euroclass C fire

More information

Xtratherm Thin-R Thermal Liner (XT/TL Grade)

Xtratherm Thin-R Thermal Liner (XT/TL Grade) CERTIFICATE NO. 03/0183 DETAIL SHEET 4 Xtratherm Thin-R Thermal Liner (XT/TL Grade) PRODUCT DESCRIPTION: This Detail Sheet relates to Xtratherm Thin-R Thermal Liner, as defined in NSAI Agrément Certificate

More information

When Self Build Becomes a Team Effort

When Self Build Becomes a Team Effort When Self Build Becomes a Team Effort The Self Build Guide to achieving a practical, affordable energy efficient home. www.xtratherm.ie With you when building your energy efficient home. The goal of achieving

More information

d1c standard construction drawings new build aggregate PART fill 6 digit product code unique to Travis Perkins Group

d1c standard construction drawings new build aggregate PART fill 6 digit product code unique to Travis Perkins Group new build standard construction drawings d1c aggregate PART fill 6 digit product code unique to Travis Perkins Group 1 Welcome to Sustainable Building Solutions (SBS) is a specialist division of the Travis

More information

Taking the Devil out of the Detail?

Taking the Devil out of the Detail? Insulation First Issue March 2017 Taking the Devil out of the Detail? AN EVALUATION OF ψ VALUES FOR KINGSPAN KOOLTHERM CAVITY CLOSER Low Energy Low Carbon Buildings Contents Page Executive Summary 3 Background

More information

Superior Performance Phenolic Insulation SR/UF. Insulation for Ground Supported and Suspended Floors. Floors AS LOW AS 10/4803

Superior Performance Phenolic Insulation SR/UF. Insulation for Ground Supported and Suspended Floors. Floors AS LOW AS 10/4803 Superior Performance Phenolic Insulation Floors SR/UF Insulation for Ground Supported and Suspended Floors AS LOW AS 020 10/4803 Data Sheet Safe-R Under Floor SR/UF is a superior performance rigid phenolic

More information

Superior Performance Phenolic Insulation. SR/CW Insulation for Partial Fill Cavity Walls. Walls AS LOW AS 10/4803

Superior Performance Phenolic Insulation. SR/CW Insulation for Partial Fill Cavity Walls. Walls AS LOW AS 10/4803 Superior Performance Phenolic Insulation Walls SR/CW Insulation for Partial Fill Cavity Walls AS LOW AS 020 10/4803 Data Sheet SR/CW Insulation for Partial Fill Cavity Walls Safe-R SR/CW Partial Fill cavity

More information

INSULATION, PLASTERBOARD & BUILDING REGULATIONS

INSULATION, PLASTERBOARD & BUILDING REGULATIONS 2016 / 2017 INSULATION, PLASTERBOARD & BUILDING REGULATIONS ENGLA D EDITION N The key to success Keep compliant by using the products MKM stock Continue using traditional construction methods Trust your

More information

Superior Performance Phenolic Insulation. SR/FB Insulation for Steel and Timber Frame. Walls AS LOW AS 10/4803

Superior Performance Phenolic Insulation. SR/FB Insulation for Steel and Timber Frame. Walls AS LOW AS 10/4803 Superior Performance Phenolic Insulation Walls Insulation for Steel and Timber Frame AS LOW AS 020 10/4803 Data Sheet Insulation for Steel and Timber Frame Safe-R Framing Board is designed for use with

More information

Superior Performance Phenolic Insulation. SR/FB Insulation for Steel and Timber Frame. Walls AS LOW AS 10/4803

Superior Performance Phenolic Insulation. SR/FB Insulation for Steel and Timber Frame. Walls AS LOW AS 10/4803 Superior Performance Phenolic Insulation Walls Insulation for Steel and Timber Frame AS LOW AS 020 10/4803 Data Sheet Insulation for Steel and Timber Frame Safe-R Framing Board is designed for use with

More information

Refurbishment site guidance for solid-walled houses roofs

Refurbishment site guidance for solid-walled houses roofs GOOD PRACTICE GUIDE 296 Refurbishment site guidance for solid-walled houses roofs What energy savings to aim for Key points to consider Energy savings and SAP ratings Environmental considerations GOOD

More information

An introduction to Part L U-values

An introduction to Part L U-values December 2010 An introduction to Part L This document provides a wide selection of building fabric constructions with their associated. It has been produced a support to our publication An introduction

More information

A handbook of thermal bridging details incorporating Porotherm blocks

A handbook of thermal bridging details incorporating Porotherm blocks A handbook of thermal bridging details incorporating Porotherm blocks Book 7 Thermal bridging solutions for external wall cavity details using Porotherm Prepared for Wienerberger Ltd by the BBA Constructive

More information

Project name Gentoo Retrofit Bid 1 Project summary Refurbishment of 2no. Semi Detached houses using Passivhaus principles

Project name Gentoo Retrofit Bid 1 Project summary Refurbishment of 2no. Semi Detached houses using Passivhaus principles http://lowenergybuildings.org.uk Project name Gentoo Retrofit Bid 1 Project summary Refurbishment of 2no. Semi Detached houses using Passivhaus principles Project Description Projected build start date

More information

CHAPTER 13: Sustainability

CHAPTER 13: Sustainability CONTENTS 13.1 THE CODE FOR SUSTAINABLE HOMES 13.2 LOW CARBON / LOW ENERGY HOMES 13.3 AIR TIGHTNESS AND ROBUSTNESS 13.4 RENEWABLE ENERGY SOURCES Chapter 13 FUNCTIONAL REQUIREMENTS FUNCTIONAL REQUIREMENTS

More information

CI/SfB (23) Suspended Timber Floor Applications Can be used with Floorboards or Tongue & Groove floor paneling Joist end Fitting Aluminium Foil Bubble Insulation General Purpose Insulation Dry Lining Insulation

More information

> Performance requirements: Part L UK vs Energiesprong vs Passivhaus.

> Performance requirements: Part L UK vs Energiesprong vs Passivhaus. > Performance requirements: Part L UK vs Energiesprong vs Passivhaus. Introduction The purpose of this paper is to highlight and compare the difference in performance requirements between UK Building Regulations

More information

PIR Insulation XT/CWP (T&G) Insulation for Partial Fill Cavity Walls. Walls 08/ /0324

PIR Insulation XT/CWP (T&G) Insulation for Partial Fill Cavity Walls. Walls 08/ /0324 PIR Insulation Walls XT/CWP (T&G) Insulation for Partial Fill Cavity Walls 08/4613 08/0324 Data Sheet Thin-R Partial Fill Cavity Wall Plus XT/CWP (T&G) builds to a system thanks to its engineered tongue

More information

Xtratherm Thin-R Thermal Liner (XT/TL Grade)

Xtratherm Thin-R Thermal Liner (XT/TL Grade) CERTIFICATE NO. 03/0183 DETAIL SHEET 4 Xtratherm Thin-R Thermal Liner (XT/TL Grade) PRODUCT DESCRIPTION: This Detail Sheet relates to Xtratherm Thin-R Thermal Liner, as defined in NSAI Agrément Certificate

More information

Refurbishment site guidance for solid-walled houses ground floors

Refurbishment site guidance for solid-walled houses ground floors GOOD PRACTICE GUIDE 294 Refurbishment site guidance for solid-walled houses ground floors What energy savings to aim for Key points to consider Energy savings and SAP ratings Environmental considerations

More information

Insulation options. Calculating U-Values

Insulation options. Calculating U-Values April 2017 Data Sheet 8 Aggregate concrete blocks External walls thermal performance Uniclass L3221 :A4 CI/SfB EPIC F611 :X221 Ff2 (Ajv) Concrete Block Association The Old Rectory, 8 Main Street, Glenfield

More information

Suspended Timber Floor Applications Can be used with Floorboards or Tongue & Groove floor paneling Aluminium Foil Bubble Insulation Joist end Fitting General Purpose Insulation Dry Lining Insulation System

More information

EcoHome-Insulation.com. Aluminium Foil Bubble Insulation. General Purpose Insulation. Dry Lining. Cavity Wall. Insulation System.

EcoHome-Insulation.com. Aluminium Foil Bubble Insulation. General Purpose Insulation. Dry Lining. Cavity Wall. Insulation System. Suspended Timber Floor Applications Can be used with Floorboards or Tongue & Groove floor paneling Aluminium Foil Bubble Insulation Joist end Fitting General Purpose Insulation Dry Lining Insulation System

More information

A Handbook of thermal bridging details incorporating aircrete blocks

A Handbook of thermal bridging details incorporating aircrete blocks A Handbook of thermal bridging details incorporating aircrete blocks Book 2 Thermal bridging solutions for external wall full fill cavity details Prepared for the Aircrete Products Association by the BBA

More information

Suspended timber upper floors

Suspended timber upper floors Exposed Soffit Floors Exposed soffit Exposed soffit design Many clients perceive that rooms above exposed upper floors will be cold. However, it is possible to achieve very high levels of thermal insulation

More information

The effect of Building Regulations (Part L1 2002) on existing dwellings

The effect of Building Regulations (Part L1 2002) on existing dwellings GENERAL INFORMATION LEAFLET 70 The effect of Building Regulations (Part L1 2002) on existing dwellings Information for installers and builders for extensions and alterations in England and Wales " Insulation

More information

PIR Insulation XT/HYF (T&G) Insulation for Ground Supported and Suspended Floors. Floors 08/ /0324

PIR Insulation XT/HYF (T&G) Insulation for Ground Supported and Suspended Floors. Floors 08/ /0324 PIR Insulation Floors XT/HYF (T&G) Insulation for Ground Supported and Suspended Floors 08/4613 08/0324 Data Sheet XT/HYF (T&G) Insulation for Ground Supported and Suspended Floors The floor in any building

More information

Building Typology Brochure England September 2014

Building Typology Brochure England September 2014 Building Typology Brochure England September 2014 Disclaimer The sole responsibility for the content of this publication lies with the authors. It does not necessarily reflect the opinion of the European

More information

LABC REGISTERED THERMAL SYSTEMS TO PART L

LABC REGISTERED THERMAL SYSTEMS TO PART L LABC REGISTERED THERMAL SYSTEMS TO PART L 2006 AND 2010 MULTI-FOIL INSULATION AND BREATHER MEMBRANES Contents 1 Foreword...4 2 How TLX Multi-foils Work...5 3 The TLX Range...6 4 U Values and Condensation

More information

Building Sustainability & Compliance

Building Sustainability & Compliance November 2011 WELCOME TO THE STROMA OCDEA TECHNICAL BULLETIN! This bulletin has been produced as a response to the latest full SAP conventions release, to ensure that our assessors are fully informed and

More information

Engineers Ireland Cork Region CPD lecture series

Engineers Ireland Cork Region CPD lecture series Engineers Ireland Cork Region CPD lecture series NZEB and Emerging Legislation & SEAI s Deep Retrofit Pilot Programme Orla Coyle NZEB Programme Manager Conor Hanniffy Deep Retrofit Pilot Programme Manager

More information

LABC RegisteRed thermal systems to PARt L 2006 And 2010 multi-foil insulation And BReAtheR membranes

LABC RegisteRed thermal systems to PARt L 2006 And 2010 multi-foil insulation And BReAtheR membranes LABC Registered Thermal Systems to Part L 2006 and 2010 multi-foil insulation and breather membranes Contents 1 Foreword...4 2 How TLX Multi-foils Work...5 3 The TLX Range...6 4 U Values and Condensation

More information

External Walls Thermal Performance

External Walls Thermal Performance External Walls Thermal Performance Data Sheet 8 October 2017 Uniclass L3221 :A4 EPIC F611 :X221 CI/SfB Ff2 (Ajv) Introduction This data sheet gives guidance for the specification of blocks in conjunction

More information

Project Description. Projected build start date 02 Aug 2010 Projected date of occupation 03 Dec

Project Description. Projected build start date 02 Aug 2010 Projected date of occupation 03 Dec http://lowenergybuildings.org.uk Project name Hounslow Council Passivhaus Retrofit - and the development of a decision making matrix Project summary The house is a 3-bedroom semi-detached single-family

More information

Building Fabric Performance beyond simple U-values

Building Fabric Performance beyond simple U-values Building Fabric Performance beyond simple U-values Giving building professionals the highest level of support from design stage to delivery of real performance on site through the assurance of a validation

More information

Building Fabric Performance beyond simple U-values

Building Fabric Performance beyond simple U-values Building Fabric Performance beyond simple U-values Giving building professionals the highest level of support from design stage to delivery of real performance on site through the assurance of a validation

More information

An introduction to Part L 2010

An introduction to Part L 2010 October 2010 An introduction to Part L 2010 Straight talking solutions Contents Section 1 The Approved Document 03-07 Introduction to changes Road to Zero Carbon Implementation and transitional Period

More information

Garage Conversion - Between and Under Joist Applications

Garage Conversion - Between and Under Joist Applications Issue 1, August 2013 CI/SfB (2 -) Rn7 (M2) Garage Conversion - Between and Under Joist Applications Flat Roof Insulation Introduction Celotex is the brand leading manufacturer of PIR insulation boards,

More information

Part L 2010 Energy Performance Certificates

Part L 2010 Energy Performance Certificates Introduction Timescales for Implementation Changes to Changes for New Buildings Changes for Existing Buildings Part L 2010 Energy Performance Certificates Summary Version A: Sept 2010 Introduction Government

More information

Building Control. A Guide to Compliance When Designing Domestic Extensions

Building Control. A Guide to Compliance When Designing Domestic Extensions Building Control Technical Guidance Leaflet No. 18 Approved Document L1B 2010 Conservation of Fuel and Power This leaflet is one of a series produced by the Hertfordshire Building Control Technical Forum

More information

Project Description. Projected build start date Projected date of occupation. Existing external wall construction.

Project Description. Projected build start date Projected date of occupation. Existing external wall construction. http://lowenergybuildings.org.uk Project name Admirals Hard Project summary FINALIST of the UK Passivhaus Awards 2015 - Situated on the Stonehouse peninsula, by the banks of the River Tamar, Number 3 Admirals

More information

Xtratherm Thin-R Underfloor Board (XT/UF Grade)

Xtratherm Thin-R Underfloor Board (XT/UF Grade) CERTIFICATE NO. 03/0183 DETAIL SHEET 3 Xtratherm Thin-R Underfloor Board (XT/UF Grade) PRODUCT DESCRIPTION: This Detail Sheet relates to Xtratherm Thin-R Underfloor Board, as defined in NSAI Agrément Certificate

More information

Thermal Laminate Board.

Thermal Laminate Board. Thermal Laminate Board www.speedlinedrywall.co.uk The Dry Lining and Thermal Insulation Solution The Dry Lining and Thermal Insulation Solution Around a third of all heat lost within un-insulated or poorly

More information

Part L Review New Domestic Buildings Tom Lelyveld, AECOM

Part L Review New Domestic Buildings Tom Lelyveld, AECOM Part L Review New Domestic Buildings 2014 Tom Lelyveld, AECOM 11 th -13 th February 2014 What I will be talking about Introduction Background Key changes to Part L1A 2014 meeting the five new-build compliance

More information

Xtratherm Thin-R Partial Fill Cavity Wall Board (XT/CW Grade)

Xtratherm Thin-R Partial Fill Cavity Wall Board (XT/CW Grade) CERTIFICATE NO. 03/0183 DETAIL SHEET 1 Xtratherm Thin-R Partial Fill Cavity Wall Board (XT/CW Grade) PRODUCT DESCRIPTION This Detail Sheet relates to Xtratherm Thin-R Partial Fill Cavity Wall Board, as

More information

Energy Performance Certificate

Energy Performance Certificate Energy Performance Certificate 33, Wingfield Road NORWICH NR3 3HF Dwelling type: Date of assessment: Date of certificate: Reference number: Total floor area: Mid-terrace house 21 May 2009 21 May 2009 2998-4025-6205-6421-2074

More information

Project Description. Projected build start date 12 Apr 2010 Projected date of occupation 28 Feb

Project Description. Projected build start date 12 Apr 2010 Projected date of occupation 28 Feb http://lowenergybuildings.org.uk Project name PassivHaus Retrofit - Octavia Housing Project summary PassivHaus retrofit of a three storey solid brick Victorian terraced house in a conservation area. Produce

More information

A Design Guide to Part L: 2013

A Design Guide to Part L: 2013 A Design Guide to Part L: 2013 The very fabric of new home energy efficiency Contents Foreword Foreword A revision to Approved Document L (Conservation of Fuel and Power) of the English Building Regulations

More information

Eco-Versal. insulation. Polyisocyanurate (PIR) foam core with aluminium foil composite to both sides BASELINE TOPLINE SLIMLINE

Eco-Versal. insulation. Polyisocyanurate (PIR) foam core with aluminium foil composite to both sides BASELINE TOPLINE SLIMLINE insulation Eco-Versal A universal solution for insulating pitched roofs, floors, walls, dormer cheeks & ceilings Eco-Versal 5 in 1 Eco-Versal 5 in 1 Polyisocyanurate (PIR) foam core with aluminium foil

More information

Dwellings Energy Assessment Procedure (DEAP) for Building Regulations Compliance. Kevin O Rourke Head, Built Environment Sustainable Energy Ireland

Dwellings Energy Assessment Procedure (DEAP) for Building Regulations Compliance. Kevin O Rourke Head, Built Environment Sustainable Energy Ireland IBCI Conference 2007: Bunratty Shannon Shamrock Hotel 22-23 March 2007 Dwellings Energy Assessment Procedure (DEAP) for Building Regulations Compliance Kevin O Rourke Head, Built Environment Sustainable

More information

SAP Calculations. M & T Homes Limited. Project: Plot 2, Wombourne Road Wombourne, Swindon, South Staffordshire, DY3 4NB

SAP Calculations. M & T Homes Limited. Project: Plot 2, Wombourne Road Wombourne, Swindon, South Staffordshire, DY3 4NB SAP Calculations Client: M & T Homes Limited Project: Plot 2, Wombourne Road Wombourne, Swindon,, DY3 4NB Contact: Geoff Williams ECCO2 Limited geoffwilliams@ecco2ltd.co.uk Building Regulation Compliance

More information

Superior Performance PIR Insulation. Floors. XO/UF Insulation for Solid and Suspended Floors

Superior Performance PIR Insulation. Floors. XO/UF Insulation for Solid and Suspended Floors Superior Performance PIR Insulation Floors XO/UF Insulation for Solid and Suspended Floors 021 Data Sheet XO/UF Insulation for Solid and Suspended Floors XO/UF superior performance PIR offers excellent

More information

Energy efficiency and the Code for Sustainable Homes

Energy efficiency and the Code for Sustainable Homes CE290 Energy efficiency and the Code for Sustainable Homes Level 3 Also available: Energy efficiency guidance for level 4 Energy efficiency guidance for levels 5 and 6 Contents 1. Introduction 3 1.1 The

More information

The Building Regulations Part L Conservation of Fuel & Power 2013 Edition

The Building Regulations Part L Conservation of Fuel & Power 2013 Edition The Building Regulations 2010 Part L Conservation of Fuel & Power 2013 Edition Without looking into the technical input for SAP etc (subject to a further presentation), what does it mean in practical terms

More information

Energy Performance Certificate

Energy Performance Certificate Energy Performance Certificate 129, North Road St. Andrews BRISTOL BS6 5AH Dwelling type: Mid-terrace house Date of assessment: 7 January 2009 Date of certificate: 7 January 2009 Reference number: 8281-6129-5770-1683-9006

More information

Related party disclosure: Boiler and radiators, mains gas 35 m² 120 kwh/m² per year 20 kg/m/m per year Mid-floor flat

Related party disclosure: Boiler and radiators, mains gas 35 m² 120 kwh/m² per year 20 kg/m/m per year Mid-floor flat Energy Performance Certificate Northern Ireland 117 Lisburn Road BELFAST BT9 7AF Energy Efficiency Rating Date of assessment: Date of certificate: Reference number: Accreditation scheme: Assessor's name:

More information

Project Description. Projected build start date 01 Mar 2010 Projected date of occupation 31 May Aberdare, Rhondda Cynon Taff, Wales

Project Description. Projected build start date 01 Mar 2010 Projected date of occupation 31 May Aberdare, Rhondda Cynon Taff, Wales http://lowenergybuildings.org.uk Project name Self Heating Social Housing- the zero carbon retrofit Project summary The target for this project is to create the first UK PassivHaus retrofit using low/zero

More information

Energy Performance Certificate

Energy Performance Certificate Energy Performance Certificate 56 Clifton Street BRIGHTON BN1 3PG Dwelling type: Date of assessment: Date of certificate: Reference number: Total floor area: Mid-terrace house 30 January 2009 30 January

More information

Energy Performance Certificate

Energy Performance Certificate Energy Performance Certificate Flat 4 37, Montreal Close PEACEHAVEN BN10 8FH Dwelling type: Date of assessment: Date of certificate: Reference number: Total floor area: Mid-floor flat December 2011 8 December

More information

Your reference for Recticel PIR insulation.

Your reference for Recticel PIR insulation. Your reference for Recticel PIR insulation. INSULATION EXCELLENCE DATE: JULY 2016 Not every brand of PIR thermal insulation is as easy to install. Because we manufacture our boards to the most perfecting

More information

Guidance on U Values from Domestic Heating Design Guide

Guidance on U Values from Domestic Heating Design Guide Guidance on U Values from Domestic Heating Design Guide The following U Values are from the Domestic Heating Design Guide, and the complete publication is available for purchase from members of the Domestic

More information

BBA Information Bulletin No 3

BBA Information Bulletin No 3 BBA Information Bulletin No 3 APPROVAL INSPECTION TESTING CERTIFICATION TECHNICAL APPROVALS FOR CONSTRUCTION Reflective foil insulation Conventions for U value calculations Introduction Reflective foil

More information

Energy Performance Certificate

Energy Performance Certificate Energy Performance Certificate 26, Grange Fell Road, GRANGEOVERSANDS, LA11 6BU Dwelling type: Detached house Date of assessment: 20 November 2008 Date of certificate: Reference number: 20 November 2008

More information

Energy Performance Certificate

Energy Performance Certificate Energy Performance Certificate Flat 26 Castle Quay, Castle Lane, BEDFORD, MK40 3FE Dwelling type: Midfloor flat Date of assessment: 16 July 2008 Date of certificate: Reference number: 07 November 2008

More information

URSA TF Roll URSA GLASSWOOL.

URSA TF Roll URSA GLASSWOOL. URSA GLASSWOOL E-mail : ursauk@uralita.com URSA UK LTD Crest House 102-104 Church Road Teddington, Middlesex TW11 8PY United Kingdom Tel : 020 8977 96 97 Fax : 020 8977 94 56 Web : www.ursa-uk.co.uk E-mail

More information

XTRATHERM SAFE-R INSULATION XTRATHERM SAFE-R PARTIAL FILL CAVITY BOARD

XTRATHERM SAFE-R INSULATION XTRATHERM SAFE-R PARTIAL FILL CAVITY BOARD Xtratherm UK Ltd Park Road Holmewood Industrial Park Holmewood Chesterfield Derbyshire S42 5UY Tel: 0371 222 1033 Fax: 0371 222 1044 e-mail: info@xtratherm.com website: www.xtratherm.com APPROVAL INSPECTION

More information

Superior Performance Phenolic Insulation. SR/RS Insulation for Ventilated Rainscreen Cladding. Walls 10/4803

Superior Performance Phenolic Insulation. SR/RS Insulation for Ventilated Rainscreen Cladding. Walls 10/4803 Superior Performance Phenolic Insulation Walls SR/RS Insulation for Ventilated Rainscreen Cladding 10/4803 Data Sheet SR/RS Insulation for Ventilated Rainscreen Cladding SR/RS Rainscreen Board provides

More information

Your reference for Recticel PIR insulation. NEW PRODUCTS FOR 2015 INSULATION EXCELLENCE

Your reference for Recticel PIR insulation. NEW PRODUCTS FOR 2015 INSULATION EXCELLENCE Your reference for Recticel PIR insulation. NEW PRODUCTS FOR 1 INSULATION EXCELLENCE DATE: JUNE 1 Not every brand of PIR thermal insulation is as easy to install. Because we manufacture our boards to the

More information

The effect of Building Regulations (Part L1 2002) on existing dwellings

The effect of Building Regulations (Part L1 2002) on existing dwellings Energy Efficiency Best Practice in Housing The effect of Building Regulations (Part L1 2002) on existing dwellings Information for installers and builders for extensions and alterations in England and

More information

Energy Performance Certificate

Energy Performance Certificate Energy Performance Certificate 141, Westfield Lane, Dwelling type: Detached house MANSFIELD, NG19 6BA Date of assessment: 26 May 2008 Date of certificate: Reference number: 26 May 2008 2768-5077-6245-4478-8054

More information

Building Regulations Part L 2013 For England. Ant Wilson Director/AECOM Fellow Building Engineering AECOM

Building Regulations Part L 2013 For England. Ant Wilson Director/AECOM Fellow Building Engineering AECOM Building Regulations Part L 2013 For England Ant Wilson Director/AECOM Fellow Building Engineering AECOM 1 st May 2014 2 Building Byelaws Thermal Insulation 3 Bringing in Part L 2002 Working With DETR

More information

A continuous wall insulation system

A continuous wall insulation system A continuous wall insulation system Delivering ultimate thermal performance with the added assurance of inbuilt protection from wind driven rain. 021 Improved Thermal Conductivity CavityTherm CavityTherm

More information

Energy Performance Certificate

Energy Performance Certificate Energy Performance Certificate 5, Grange Road NORWICH NR2 3NH Dwelling type: Mid-terrace house Date of assessment: 1 December 2008 Date of certificate: 1 December 2008 Reference number: 8998-7095-0520-9706-0283

More information

Thermally Broken Lintel Product Selector

Thermally Broken Lintel Product Selector CI/Sfb Uniclass L325:P4142 March 2017 (31.9) Hh2 EPIC F631:X442 Thermally Broken Lintel Product Selector March 2017 Contents 4 Technically Superior Products 5 Thermally Broken Lintel Solution 6 Thermal

More information

Energy Performance Certificate

Energy Performance Certificate Energy Performance Certificate 17a Chart Lane REIGATE Surrey RH2 7BW Dwelling type: Date of assessment: Date of certificate: Reference number: Total floor area: Top-floor flat 30 January 2009 30 January

More information

Energy Performance Certificate

Energy Performance Certificate Energy Performance Certificate 218, Lode Lane SOLIHULL B91 2HS Dwelling type: Semi-detached house Date of assessment: 9 October 2008 Date of certificate: 12 October 2008 Reference number: 8078-6120-5059-2221-7002

More information

Project Description. Projected build start date 15 Aug 2011 Projected date of occupation 19 Dec Existing external wall construction

Project Description. Projected build start date 15 Aug 2011 Projected date of occupation 19 Dec Existing external wall construction http://lowenergybuildings.org.uk Project name Redlands Project summary Deep retrofit of 1955 brick house in Devon based on EnerPHit standard. House had old gas boiler, double glazing, cavity wall insulation

More information

Expired Report (92-100) (81-91) (69-80) (55-68) (39-54) (21-38) (1-20) Current

Expired Report (92-100) (81-91) (69-80) (55-68) (39-54) (21-38) (1-20) Current 58 Lower Paddock Road WATFORD WD19 4GS Dwelling type: Date of assessment: Date of certificate: Reference number: Total floor area: Semi-detached house 04 May 2008 05 May 2008 0946-1874-6852-0208-3025 110

More information