OG-100 ICC-SRCC TM CERTIFIED SOLAR COLLECTOR # D

Save this PDF as:
 WORD  PNG  TXT  JPG

Size: px
Start display at page:

Download "OG-100 ICC-SRCC TM CERTIFIED SOLAR COLLECTOR # D"

Transcription

1 accredited and EPA recognized Certification Body, in accordance with the SRCC OG-100 Certification Program, as defined in SRCC OG-100, Operating Guidelines and Minimum Standards for Certifying Solar Collectors. This award of certification is subject to all terms and conditions of the current OG-100 Program Agreement and the documents incorporated therein by reference. This document must be reproduced in its Climate -> Category (Ti-Ta) Kilowatt-hours (thermal) Per Panel Per Day High Radiation (6.3 kwh/m².day) Medium Radiation (4.7 kwh/m².day) COLLECTOR THERMAL PERFORMANCE RATINGS Low Radiation (3.1 kwh/m².day) Climate -> Category (Ti-Ta) Thousands of Btu Per Panel Per Day High Radiation (2000 Btu/ft².day) Medium Radiation (1500 Btu/ft².day) Low Radiation (1000 Btu/ft².day) A (-5 C) A (-9 F) B (5 C) B (9 F) C (20 C) C (36 F) D (50 C) D (90 F) E (80 C) E (144 F) TECHNICAL RESULTS Tested in accordance with: ISO Efficiency Equation [NOTE: Based on gross area and (P)=Ti-Ta] SI UNITS: η= (P/G) (P²/G) Y Intercept: Slope: W/m². C IP UNITS: η= (P/G) (P²/G) Y Intercept: Slope: Btu/hr.ft². F Incident Angle: θ Transverse IAM: Kτα Longitudinal IAM: Kτα COLLECTOR SPECIFICATIONS Gross Area: m² ft² Dry Weight: 41.3 kg 91.1 lb Net Aperture Area: m² ft² Fluid Capacity: 2.1 liter 0.6 gal REMARKS: Technical Director Print April 10, 2018 Page 1 of 5

2 ADDITIONAL INFORMATION (click here to return to the rating page) COLLECTOR TESTING INFORMATION Test Lab: Bodycote Test June 29, 2009 Test Report Number: Test Location: Test Fluid: Water Test Mass Flow Rate: kg/(s m²) lb/(hr ft²) Test Pressure: 1103 kpa 160 psi SOLAR COLLECTOR CONSTRUCTION DETAILS Header Enclosure: Gross Length: m Gross Width: m Gross Depth: Tube Bank: Gross Length: Gross Width: COLLECTOR MATERIALS Outer Cover: Other Enclosure back: Aluminum Back Insulation:, Inner Cover: None Enclosure side: Aluminum Side Insulation:, Absorber Description: Flow Pattern: Riser Tube: Stainless Steel Fin: Absorber Coating: Selective Tube to fin connection GLAZING Outer Cover Inner Cover Material: Other None Surface Characteristics: Thickness: 0.0 mm N/A Transmissivity: Gross Tube Length (uninstalled): m Diameter: m Tube Glazing to Header Enclosure Seal: Print April 10, 2018 Page 2 of 5

3 Reflector Shape: Reflector Material: ABSORBER Header Material: Header OD: Header Wall: Riser Tube Material: Stainless Steel Riser Tube OD: Riser Tube Wall Thickness: Fin Material: Fin Thickness: 0.00 mm Flow Pattern: Number of absorber tubes: Number of Flow Tubes / Heat Pipes: 12 Flow Tube to Fin Bond: Length of Flow Path: 0.00 m Riser to Fin/Plate Bond: 12 Tube / Heat Pipe Spacing: Length of Flow Path: 0.00 m INSULATION: Location Type Thickness Location Type Thickness Back Top Layer: Sides Inner Layer: Back Bottom Layer: Sides Outer Layer: Enclosure Fastening Methods: Header Enclosure: Power Output per Collector(W) [ Ti-Ta, G = 1000 W/m² ] Print April 10, 2018 Page 3 of 5

4 PRESSURE DROP Flow ΔP Flow ΔP ml/s Pa gpm in H₂ Print April 10, 2018 Page 4 of 5

5 ICC-SRCC OG-100 Certification Label The collectors listed in this certification must display the label below. The certification label must be permanently affixed to each collector in accordance with SRCC OG-100 program requirements. This product certified by the Solar Rating & Certification Corporation ICC-SRCC Certification Number: High Solar Radiation Climate Rating in Category C 9.41 kwh/day kbtu/day Print April 10, 2018 Page 5 of 5

Experimental Study of Sunearth Flat Plate Solar Collector

Experimental Study of Sunearth Flat Plate Solar Collector Experimental Study of Sunearth Flat Plate Solar Collector K.R. Anderson *1, S. Hill 2, C. Selerberg 3, E. Guiterez 4 1,2,3,4 Solar Thermal Alternative Renewable Energy Lab, Mechanical Engineering, California

More information

Sir, We hereby place an order on you for the services as described below: Collector Area (m²) No. of samples

Sir, We hereby place an order on you for the services as described below: Collector Area (m²) No. of samples APPLICATION FORM SOLAR FLAT PLATE COLLECTOR (FPC) From: - Company (Please write complete Postal address) Sir, We hereby place an order on you for the services as described below: Sr. No. Description Collector

More information

Design Considerations for Flat Plate Solar Water Heater System

Design Considerations for Flat Plate Solar Water Heater System Design Considerations for Flat Plate Solar Water Heater System 1* P. P.Patil, 2 Dr.D.S.Deshmukh. 1* Assi. Prof., Mech. Engg. Department, SGDCOE Jalgaon.MS India 2 Professor, Mech. Engg. Department, SSBT

More information

CPC EVACUATED TUBE COLLECTOR SYSTEMS FOR PROCESS HEAT UP TO 160 C

CPC EVACUATED TUBE COLLECTOR SYSTEMS FOR PROCESS HEAT UP TO 160 C CPC EVACUATED TUBE COLLECTOR SYSTEMS FOR PROCESS HEAT UP TO 6 C Rolf Meissner Ritter XL Solar GmbH e-mail: r.meissner@ritter-xl-solar.com Introduction Using water as heat transfer fluid CPC evacuated tube

More information

SOLAR COLLECTORS TITANPOWER TM FLAT PLATE & THERMOPOWER TM EVACUATED TUBES

SOLAR COLLECTORS TITANPOWER TM FLAT PLATE & THERMOPOWER TM EVACUATED TUBES SOLAR COLLECTORS TITANPOWER TM FLAT PLATE & THERMOPOWER TM EVACUATED TUBES SUPERIOR PERFORMANCE SunMaxx solar collectors are among the best performing and most efficient in the solar thermal industry CUTTING-EDGE

More information

Calculation and Fabrication of a Solar Flat Plate Collector Efficiency using Mild Steel as Absorber Plate

Calculation and Fabrication of a Solar Flat Plate Collector Efficiency using Mild Steel as Absorber Plate IJSTE - International Journal of Science Technology & Engineering Volume 3 Issue 08 February 2017 ISSN (online): 2349-784X Calculation and Fabrication of a Solar Flat Plate Collector Efficiency using Mild

More information

Thermal Analysis of Solar Flat Plate Collector

Thermal Analysis of Solar Flat Plate Collector Thermal Analysis of Solar Flat Plate Collector # Yakoob Kolipak,Associate Professor, ME Dept, E-mail:yakoob.cjits @gmail.com # Kranthi Kumar Guduru,Assistant Professor,ME Dept, E-mail: kranthicjits1@gmail.com

More information

Experimental Investigation of a New Solar Flat Plate Collector

Experimental Investigation of a New Solar Flat Plate Collector Abstract Research Journal of Engineering Sciences ISSN 2278 9472 Experimental Investigation of a New Solar Flat Plate Collector Raj Thundil Karuppa R. 1, Pavan P. 2 and Reddy Rajeev D. 3, School of Mechanical

More information

ENERGY STAR Qualifying Criteria for Residential Windows, Doors, and Skylights Sold in Canada Version 3.0 October 1, 2010

ENERGY STAR Qualifying Criteria for Residential Windows, Doors, and Skylights Sold in Canada Version 3.0 October 1, 2010 ENERGY STAR Qualifying Criteria for Residential Windows, Doors, and Skylights Sold in Canada Below is the product criteria for ENERGY STAR qualified residential windows, doors, and skylights sold in Canada

More information

Exergy analysis of a flat plate solar collector

Exergy analysis of a flat plate solar collector Exergy analysis of a flat plate solar collector Sunil Chamoli GRDIMT Dehradun, Uttarakhand, India Abstract In this study, exergetic performance analysis of flat plate solar collector has been carried out

More information

Computational Study of Hybrid Water Heater with Evacuated Glass Tube Solar Collector and Rice Husk Combustion

Computational Study of Hybrid Water Heater with Evacuated Glass Tube Solar Collector and Rice Husk Combustion Energy Research Journal 1 (2): 182-188, 2010 ISSN 1949-0151 2010 Science Publications Computational Study of Hybrid Water Heater with Evacuated Glass Tube Solar Collector and Rice Husk Combustion Piyanun

More information

Originally Issued: 12/12/2014 Revised: 12/29/2017 Valid Through: 12/29/2018

Originally Issued: 12/12/2014 Revised: 12/29/2017 Valid Through: 12/29/2018 Originally Issued: 12/12/2014 Revised: 12/29/2017 Valid Through: 12/29/2018 TK Products A Division of Sierra Corporation TK-HYDROMAX 2001 SB DAMPPROOF COATING, TK-HYDROMAX 2002 SB FOUNDATION WATERPROOF

More information

ROOFS ROOFS WALLS FLOORS. Energy efficiency for constructions... Always environment-friendly...

ROOFS ROOFS WALLS FLOORS. Energy efficiency for constructions... Always environment-friendly... PRODUCT CATALOG Energy efficiency for constructions... Always environment-friendly... www.prodexcr.com CONSTRUCTION AREA REFLECTIVE THERMAL INSULATION AD AD= ALUMINUM + ALUMINUM 0,39; 0,19; and 0,11 in

More information

ELASTOMER- METAL- ABSORBER - DEVELOPMENT AND APPLICATION

ELASTOMER- METAL- ABSORBER - DEVELOPMENT AND APPLICATION ELASTOMER- METAL- ABSORBER - DEVELOPMENT AND APPLICATION Bernd Bartelsen, Gunter Rockendorf Institut für Solarenergieforschung GmbH, Am Ohrberg, D-386 Emmerthal, Germany, Tel. +49 ()55/ 999-522, Fax -5

More information

An OEM partnership for all seasons

An OEM partnership for all seasons An OEM partnership for all seasons Flat plate collectors Vacuum tube collectors Thermosiphonic systems page 1 Having an in depth understanding of all the factors that make a successful OEM partnership

More information

SECTION SLOPED TRANSLUCENT METAL SKYLIGHT SYSTEM

SECTION SLOPED TRANSLUCENT METAL SKYLIGHT SYSTEM PART 1- GENERAL 1.1 SUMMARY A. Section Includes: SECTION 084523 - SLOPED TRANSLUCENT METAL SKYLIGHT SYSTEM 1. Flat factory prefabricated structural insulated translucent sandwich panels; with glazed endwalls.

More information

SunMaxxTM Information Guide: Evacuated Tube Solar Collectors

SunMaxxTM Information Guide: Evacuated Tube Solar Collectors SunMaxxTM Information Guide: Evacuated Tube Solar Collectors P: 877.SUNMAXX / 888.SOLAR.11 www.siliconsolar.com / www.sunmaxxsolar.com Silicon Solar Inc Innovative Solar Solutions SunMaxxTM Information

More information

Lab # BAEN/CHEN ! page 1 UNIT OPERATION IN FOOD PROCESSING Department of Biological and Agricultural Engineering Texas A&M University

Lab # BAEN/CHEN ! page 1 UNIT OPERATION IN FOOD PROCESSING Department of Biological and Agricultural Engineering Texas A&M University Lab # BAEN/CHEN-422-622! page 1 Heat Exchanger Demonstration Lab Double Pipe HE Shell & Tube HE Tubular HE BAEN/CHEN-422-622! page 2 Heat Exchanger Demonstration Lab Summary The process of heat exchange

More information

Design Optimization of a Non-evacuated CPC Collector

Design Optimization of a Non-evacuated CPC Collector Design Optimization of a Non-evacuated CPC Collector Dariush Zare a,*, Hossein Ebadi a a Biosystems Engineering Department, College of Agriculture, Shiraz University, Shiraz, Fars, Iran * Corresponding

More information

Fire Barrier Duct Wrap 615+

Fire Barrier Duct Wrap 615+ Fire Barrier Duct Wrap 615+ Duct Wrap Fire Protection System for Commercial Kitchen Grease and Ventilation Air Ducts Product Data Batts and blankets for use in fire resistive duct assemblies see UL fire

More information

AR No. # Solar Thermal. Assessment Recommendation Savings Summary Source. Cost Savings Natural Gas. $984 * 1 MMBtu = 1,000,000 Btu

AR No. # Solar Thermal. Assessment Recommendation Savings Summary Source. Cost Savings Natural Gas. $984 * 1 MMBtu = 1,000,000 Btu AR No. # Solar Thermal Recommendation We recommend installing a solar thermal array on the building roof. This will provide an alternative source for 9.8% of the facilities energy consumption and reduce

More information

Administrative Changes

Administrative Changes Revised 11/29/06 Knox County Residential Building Codes Significant Changes From The 1995 CABO One And Two Family Dwelling Code To The 2006 International Residential Code All one and two family dwellings

More information

AR No. # - Solar Thermal

AR No. # - Solar Thermal AR No. # - Solar Thermal Recommendation We recommend installing a solar thermal array on the building roof. This will provide an alternative source for 10% of the facilities energy consumption and reduce

More information

Baltimore County Detention Center Expansion Towson, Maryland

Baltimore County Detention Center Expansion Towson, Maryland V. Active Solar System Introduction After the energy crises of the 1970s and the subsequent increases in the cost of petroleumbased fuels, interest in active solar energy systems surged. Thousands of active

More information

ANSI/ASHRAE STANDARD , METHODS OF TESTING CHILLED BEAMS

ANSI/ASHRAE STANDARD , METHODS OF TESTING CHILLED BEAMS ANSI/ASHRAE STANDARD 200-2015, METHODS OF TESTING CHILLED BEAMS NEMIC 2017 Agenda 1. Foreword 2. Purpose & Scope 3. Definitions 4. Instrumentation & Facilities 5. Test Methods 6. Reporting 7. Normative

More information

U-Factor, Solar Heat Gain Coefficient, Visible Transmittance and Condensation Resistance Calculation Report

U-Factor, Solar Heat Gain Coefficient, Visible Transmittance and Condensation Resistance Calculation Report U-Factor, Solar Heat Gain Coefficient, Visible Transmittance and Condensation Resistance Calculation Report REPORT NO: SIMULATION DATE: 5/25/2016 REPORT DATE: 6/2/2016 Client: Product Line: Specification:

More information

Optimisation and Cost Analysis of a Lithium Bromide Absorption Solar Cooling System

Optimisation and Cost Analysis of a Lithium Bromide Absorption Solar Cooling System Optimisation and Cost Analysis of a Lithium Bromide Absorption Solar Cooling System Georgios A. Florides and Soteris A. Kalogirou Mechanical Engineering Department, Higher Technical Institute, Nicosia,

More information

Cryogenic Pipe Support Systems

Cryogenic Pipe Support Systems Cryogenic Pipe Support Systems Overview Rilco cryogenic pipe supports are developed to support cold piping in various applications ranging from chilled water to liquefied natural gas. The qualified service

More information

PHOTOVOLTAIC SOLAR ENERGY POLYCRYSTALLINE MODULES - SI-ESF-M-P156-60

PHOTOVOLTAIC SOLAR ENERGY POLYCRYSTALLINE MODULES - SI-ESF-M-P156-60 Solar Innova uses the latest materials to manufacture photovoltaic modules. Our modules are ideal for any application that uses the photoelectric effect as a clean energy source because of its minimal

More information

Experimental investigation of single-phase and twophase closed thermosyphon solar water heater systems

Experimental investigation of single-phase and twophase closed thermosyphon solar water heater systems Scientific Research and Essays Vol. 6(4), pp. 688-693, 18 February, 2011 Available online at http://www.academicjournals.org/sre DOI: 10.5897/SRE09.072 ISSN 1992-2248 2011 Academic Journals Full Length

More information

KERTO HEADER INSULATED LVL HEADER 31/2", 51/2" 3 1/2" AND 5 1/2" THICKNESSES DESIGN VALUES USA

KERTO HEADER INSULATED LVL HEADER 31/2, 51/2 3 1/2 AND 5 1/2 THICKNESSES DESIGN VALUES USA KERTO USA page 1/12 KERTO INSULATED LVL 3 1/2" AND 5 1/2" THICKNESSES DESIGN VALUES USA KERTO USA page 2/12 TABLE OF CONTENTS 3 Specification Guide 4 About Kerto Header 5 Insulation Values 6 Maximum Loads

More information

Tube Insulation. Fiber Free

Tube Insulation. Fiber Free Fiber Free Tube Insulation Fiber-free, flexible, elastomeric pipe insulation for reliable protection against condensation, mold, energy loss and ultraviolet radiation in residential and commercial applications

More information

Faculty of Heat and Material Transfer Rheinisch-Westfälische Technische Hochschule, Aachen Professor R. Kneer (Dr. Ing)

Faculty of Heat and Material Transfer Rheinisch-Westfälische Technische Hochschule, Aachen Professor R. Kneer (Dr. Ing) Faculty of Heat and Material Transfer Rheinisch-Westfälische Technische Hochschule, Aachen Professor R. Kneer (Dr. Ing) Calculations of thermal transmission by radiation with the use of Aluthermo Quattro

More information

DINAK Camiño do Laranxo, , VIGO (SPAIN) DIFLUX POLYPOPRYLENE. TÜV Industrie Service GmbH TÜV SÜD Gruppe 0036 CPD

DINAK Camiño do Laranxo, , VIGO (SPAIN) DIFLUX POLYPOPRYLENE. TÜV Industrie Service GmbH TÜV SÜD Gruppe 0036 CPD Rev.2 DECLARATION OF CONFORMITY AND PRODUCT DESCRIPTION 14471 Chimneys - System chimneys with plastic flue liners - Requirements and test methods Manufacturer: Product commercial name: Product description:

More information

PHOTOVOLTAIC SOLAR ENERGY POLYCRYSTALLINE MODULES - SI-ESF-M-BIPV-SM-P125-36

PHOTOVOLTAIC SOLAR ENERGY POLYCRYSTALLINE MODULES - SI-ESF-M-BIPV-SM-P125-36 Solar Innova uses the latest materials to manufacture photovoltaic modules. Our modules are ideal for any application that uses the photoelectric effect as a clean energy source because of its minimal

More information

Analysis of Solar Flat Plate Collector

Analysis of Solar Flat Plate Collector Analysis of Solar Flat Plate Collector B. K. Gond 1, S. Mittal 2, P. Prajapati 3, R. Khare 4 1 Mechanical Engineering Department 1-4 University Institute of Technology, Barkatullah University, Bhopal,

More information

Technical Information

Technical Information General Applications Process Applications Determining Heat Energy Lost The objective of any heating application is to raise or maintain the temperature of a solid, liquid or gas to or at a level suitable

More information

SOLAR KEYMARK SPECIFIC SCHEME RULES ANNEX E: FACTORY PRODUCTION CONTROL INFORMATIVE BASED ON ISO 9001 STANDARD COVERING THE PRODUCTION LINE

SOLAR KEYMARK SPECIFIC SCHEME RULES ANNEX E: FACTORY PRODUCTION CONTROL INFORMATIVE BASED ON ISO 9001 STANDARD COVERING THE PRODUCTION LINE SOLAR KEYMARK SPECIFIC SCHEME RULES ANNEX E: FACTORY PRODUCTION CONTROL INFORMATIVE BASED ON ISO 9001 STANDARD COVERING THE PRODUCTION LINE 1. General This annex specifies the requirements for the Factory

More information

STAINLESS STEEL SHEETS

STAINLESS STEEL SHEETS STAINLESS & NICKEL ALLOY CHATHAM STEEL CORPORATION 59 STAINLESS STEEL SHEETS TYPE 04, 04L, 6, 6L No. 2B Finish Cold Rolled, Annealed *No. 2D Finish No. Finish Polished One Side No. 4 Finish Polished One

More information

GUIDE SPECIFICATION EXETER SECURITY SHIELD SECURITY WINDOW BARRIER SYSTEM

GUIDE SPECIFICATION EXETER SECURITY SHIELD SECURITY WINDOW BARRIER SYSTEM 1 GUIDE SPECIFICATION EXETER SECURITY SHIELD SECURITY WINDOW BARRIER SYSTEM 1.01 WORK INCLUDED PART 1: GENERAL A. Provide for all labor, equipment, materials and services to furnish and install SECURITY

More information

INIZIATIVE INDUSTRIALI

INIZIATIVE INDUSTRIALI INIZIATIVE INDUSTRIALI S.p.A. Sarplast is a company located in Santa Luce (Pisa, Italy) which has over 35 years experience in the design, manufacturing and supply of Glass-Fiber Reinforced Plastic (GRP)

More information

CFFWA-20-1-U Chilled/Hot Water Universal Mount Fan Coil 2-Pipe Heat / Cool Fan Coil 60,000 BTUH

CFFWA-20-1-U Chilled/Hot Water Universal Mount Fan Coil 2-Pipe Heat / Cool Fan Coil 60,000 BTUH CFFWA-20-1-U Chilled/Hot Water Universal Mount Fan Coil 2-Pipe Heat / Cool Fan Coil 60,000 BTUH Rev. 1.3 HVAC Guide Specifications Chilled and Hot Water Universal Mount Fan Coil 2-Pipe Nominal Size: 60,000

More information

thermal solutions LOW Finned Tubes

thermal solutions LOW Finned Tubes thermal solutions LOW Finned Tubes GEWA-K, GEWA-KS Low Finned Tubes GEWA-k, GEWA-KS Wieland GEWA-K and GEWA-KS tubes are low finned tubes in copper and copper alloys as well as carbon steel, stainless

More information

Penn State AE Senior Thesis 2009

Penn State AE Senior Thesis 2009 Penn State AE Senior Thesis 2009 Project Overview Location Baltimore, MD Size 107,000SF/6 Stories Schedule March 2007 to September 2008 Cost $27.5 Million (Est.) Structure Cast in Place Post-Tension Concrete

More information

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS SECTION: METAL WALL PANELS REPORT HOLDER:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS SECTION: METAL WALL PANELS REPORT HOLDER: 0 Most idely Accepted and Trusted ICC-ES Report ICC-ES 000 (800) 423-687 (62) 699-043 www.icc-es.org ESR-199 Reissued 0/2017 This report is subject to renewal 0/2019. DIVISION: 07 00 00 THERMAL AND MOISTURE

More information

T700 SERIES(AW50)-Impact (Formerly 8050 series) SINGLE HUNG 3 1/4 FRAME DEPTH (SIDE LOAD)

T700 SERIES(AW50)-Impact (Formerly 8050 series) SINGLE HUNG 3 1/4 FRAME DEPTH (SIDE LOAD) T700 SERIES(AW50)-Impact (Formerly 8050 series) SINGLE HUNG 3 1/4 FRAME DEPTH (SIDE LOAD) FEATURES 1.) Available Configurations -Single hung -Oriel style (optional) 2.) Main frame / Sash -Drop-in glazing

More information

FLATE Hillsborough Community College - Brandon (813)

FLATE Hillsborough Community College - Brandon (813) The Florida Advanced Technological Education (FLATE) Center wishes to make available, for educational and noncommercial purposes only, materials relevant to the EST1830 Introduction to Alternative/Renewable

More information

E APPENDIX. The following problems are intended for solution using finite element. Problems for Computer Solution E.1 CHAPTER 3

E APPENDIX. The following problems are intended for solution using finite element. Problems for Computer Solution E.1 CHAPTER 3 E APPENDIX Problems for Computer Solution The following problems are intended for solution using finite element analysis software. In general, the problems associated with Chapters 3, 4, and 9 can be solved

More information

THE MICROFLOW SENSOR MICROFLOW SENSOR WITH A WIDE RANGE OF APPLICATIONS THANKS TO THE AVAILABILITY OF DIFFERENT CONNECTION TYPES

THE MICROFLOW SENSOR MICROFLOW SENSOR WITH A WIDE RANGE OF APPLICATIONS THANKS TO THE AVAILABILITY OF DIFFERENT CONNECTION TYPES THE MICROFLOW SENSOR MICROFLOW SENSOR WITH A WIDE RANGE OF APPLICATIONS THANKS TO THE AVAILABILITY OF DIFFERENT CONNECTION TYPES The manufacturer guarantees only English text. Available on our web site:

More information

movable walls Space Optimal Solutions

movable walls Space Optimal Solutions Space Optimal Solutions www.movablewall.co.uk by dividing, we multiply Prestige-Space for every occasion From a large meeting room you then have several smaller ones at your disposal Your hotel instantly

More information

5. AMCA 301 Method of Publishing Sound Ratings for Air Moving Devices. 6. AMCA 500 Test Methods for Louver, Dampers, and Shutters

5. AMCA 301 Method of Publishing Sound Ratings for Air Moving Devices. 6. AMCA 500 Test Methods for Louver, Dampers, and Shutters PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

1 Exam Prep 2014 Florida Building Code -Energy Conservation Questions and Answers

1 Exam Prep 2014 Florida Building Code -Energy Conservation Questions and Answers 1 Exam Prep 2014 Florida uilding ode -Energy onservation Questions and nswers 1. steam type heating system has a fluid design operating temperature of 275 degrees Fahrenheit and a nominal pipe diameter

More information

Electrical/thermal performance of hybrid PV/T system in Sharjah, UAE

Electrical/thermal performance of hybrid PV/T system in Sharjah, UAE International Journal of Smart Grid and Clean Energy Electrical/thermal performance of hybrid PV/T system in Sharjah, UAE Amna A. Alzaabi a, Nadine K. Badawiyeh a, Hind O. Hantoush a, A. K. Hamid b* a

More information

STRONG SEAM PANELING SYSTEM TANK INSULATION SYSTEM www.sli-services.com TANK INSULATION SYSTEM A Strong Seam tank insulation system minimizes long-term maintenance requirements and also lowers the cost

More information

The Concept of Linear and Point Transmittance and its Value in Dealing with Thermal Bridges in Building Enclosures

The Concept of Linear and Point Transmittance and its Value in Dealing with Thermal Bridges in Building Enclosures The Concept of Linear and Point Transmittance and its Value in Dealing with Thermal Bridges in Building Enclosures BEST3, April 2012 Neil Norris, MaSc Patrick Ropell, B.Eng. Mark Lawton, P.Eng MH Vancouver

More information

Design of Experiment for Solar Water Heater Performance Analysis

Design of Experiment for Solar Water Heater Performance Analysis Design of Experiment for Solar Water Heater Performance Analysis Mr. M.V. Kulkarni 1, Dr. D. S Deshmukh 2, 1 Asst. Professor, Department of Mechanical Engineering, SSBT'S COLLEGE OF ENGINEERING AND TECHNOLOGY,

More information

Design, CFD Analysis and Fabrication of Solar Flat Plate Collector

Design, CFD Analysis and Fabrication of Solar Flat Plate Collector Design, CFD Analysis and Fabrication of Solar Flat Plate Collector Prof. Kumavat Mukesh Manilal Assistant Professor, Mechanical Engineering Department, SND COE & RC Yeola, Maharashtra, India ---------------------------------------------------------------------***---------------------------------------------------------------------

More information

Observation of Liquid-filled Window without Presence of Liquid in Test Chamber

Observation of Liquid-filled Window without Presence of Liquid in Test Chamber SSP - JOURNAL OF CIVIL ENGINEERING Vol. 11, Issue 2, 2016 DOI: 10.1515/sspjce-2016-0020 Observation of Liquid-filled Window without Presence of Liquid in Test Chamber Ján Lojkovics Technical University

More information

Figure 5 - A shoring tower is made by assembling end frames with diagonal braces

Figure 5 - A shoring tower is made by assembling end frames with diagonal braces Figure 5 - A shoring tower is made by assembling end frames with diagonal braces Figure 6 shows shoring towers being used in the construction of the new Computer Science building at the University of Washington

More information

Gas Fireplaces. P36D-10 Gas Fireplace. Unit Dimensions With Vignette Faceplate. *** Important: Framing height requires consideration of the hearth

Gas Fireplaces. P36D-10 Gas Fireplace. Unit Dimensions With Vignette Faceplate. *** Important: Framing height requires consideration of the hearth 28-15/16 (735mm) Model P36D-NG10 P36D-LP10 Fuel Type Natural Gas Propane Gas Fireplaces Minimum Supply Pressure Manifold Pressure - High Manifold Pressure - Low 5 W.C. (1.25 kpa) 3.8 W.C. (0.95 kpa) 1.1

More information

Product information Additional window element GIU

Product information Additional window element GIU Edition 1.0 15.12.2014 Product information Additional window element Product description High quality moulded polyurethane with white lacquer finish Fixed window element (non opening) For installation

More information

Design, construction and evaluation of a system of forced solar water heating.

Design, construction and evaluation of a system of forced solar water heating. IOP Conference Series: Materials Science and Engineering PAPER OPEN ACCESS Design, construction and evaluation of a system of forced solar water heating. To cite this article: E Hernández et al 2016 IOP

More information

adaptable 2014 CONCEPT MODULAR PREFAB - MODULI ABITATIVI PREFABBRICATI

adaptable 2014 CONCEPT MODULAR PREFAB - MODULI ABITATIVI PREFABBRICATI The accurate study of the proportions and modularity, led us to design a elementary module from the standard dimensions of around 2,5 x 5,5 x 3 meters. All modules are designed for minimal waste of space

More information

Comments, if any, may please be made in the format as given overleaf and ed to the undersigned at the above address.

Comments, if any, may please be made in the format as given overleaf and  ed to the undersigned at the above address. DRAFT STANDARD UNDER WIDE CIRCULATION DOCUMENT DESPATCH ADVICE Ref: MED 04/T-22,23 & 24 Date: 13-05-2015 Renewable Energy Sources Sectional Committee, MED 04 TO: a) The interested members of Mechanical

More information

Optimization of embedded Heat Exchanger in a flat plate Integrated Collector Storage Solar Water Heater (ICSSWH), with indirect heat withdrawal.

Optimization of embedded Heat Exchanger in a flat plate Integrated Collector Storage Solar Water Heater (ICSSWH), with indirect heat withdrawal. World Renewable Energy Congress (WRECX) Editor A. Sayigh 2008 WREC. All rights reserved. 1815 Optimization of embedded Heat Exchanger in a flat plate Integrated Collector Storage Solar Water Heater (ICSSWH),

More information

Product information Centre-pivot white-painted roof window GGL

Product information Centre-pivot white-painted roof window GGL Edition 2.0 13.09.2017 Product information Centre-pivot white-painted roof window Product description High quality natural pinewood coated with impregnation and layers of water-based acrylic white paint

More information

Performance Evaluation of Flat Plate Solar Collector (Model Te39) In Bauchi

Performance Evaluation of Flat Plate Solar Collector (Model Te39) In Bauchi American Journal of Engineering Research (AJER) 2014 American Journal of Engineering Research (AJER) e-issn : 2320-0847 p-issn : 2320-0936 Volume-3, Issue-10, pp-34-40 www.ajer.org Research Paper Open

More information

Height Finish Pole Options. Series Optics Mounting Lamping Finish Voltage. Metal Halide HPS. H w H070 70w H w H w

Height Finish Pole Options. Series Optics Mounting Lamping Finish Voltage. Metal Halide HPS. H w H070 70w H w H w Series Optics Mounting Lamping / Wattage Finish Voltage SAMG Saturn Magnum MR Type V MTR* 6 Refractor Refractor is an integral part of the fixture and is not an option. Project: Type: SAMG MR Series Optics

More information

An investigation on the performance characteristics of solar flat plate collector with different selective surface coatings

An investigation on the performance characteristics of solar flat plate collector with different selective surface coatings INTERNATIONAL JOURNAL OF ENERGY AND ENVIRONMENT Volume 3, Issue 1, 2012 pp.99-108 Journal homepage: www.ijee.ieefoundation.org An investigation on the performance characteristics of solar flat plate collector

More information

2 kw. ak.com. www. Energy report

2 kw. ak.com. www. Energy report 2 kw Thermal System Example of SolarPeak residential installation Energy report Find your closest agent www w.solarpea ak.com SolarPeak Head Office ops@ @SolarPeak.com (3) 547 58 19 Nelson 1 What is this

More information

ANSI/AAMA/NWWDA 101/I.S.2-97 TEST REPORT. Rendered to: MASTER WINDOW SYSTEMS, INC.

ANSI/AAMA/NWWDA 101/I.S.2-97 TEST REPORT. Rendered to: MASTER WINDOW SYSTEMS, INC. ANSI/AAMA/NWWDA 101/I.S.2-97 TEST REPORT Rendered to: MASTER WINDOW SYSTEMS, INC. SERIES/MODEL: Master 1000 Sliding Window PRODUCT: PVC Horizontal Sliding Window Summary of Results Title Test Specimen

More information

Side by side tests of two SDHW systems with solar collectors with and without antireflection treatment

Side by side tests of two SDHW systems with solar collectors with and without antireflection treatment Downloaded from orbit.dtu.dk on: Mar 31, 2018 Side by side tests of two SDHW systems with solar collectors with and without antireflection treatment Kong, Weiqiang; Han, Jiangong; Perers, Bengt; Furbo,

More information

Florida HERO Program Residential Eligible Product List All Products

Florida HERO Program Residential Eligible Product List All Products All Products In addition to the HERO Product Eligibility Specifications listed below, it is the sole responsibility of the HERO Contractor and property owner (Project Stakeholders) to meet or exceed applicable

More information

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS SECTION: METAL WALL PANELS REPORT HOLDER:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS SECTION: METAL WALL PANELS REPORT HOLDER: 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 4 6587 (562) 699 0543 www.icc es.org ESR 3152 Reissued 08/2017 This report is subject to renewal 08/2018. DIVISION: 07 00 00

More information

Glazed photovoltaic-thermal component for building envelope structures

Glazed photovoltaic-thermal component for building envelope structures Glazed photovoltaic-thermal component for building envelope structures Tomas Matuska 1, Nikola Pokorny 1, Petr Slanina 2 1 Czech Technical University in Prague, Czech Republic 2 Skanska LOP, Prague, Czech

More information

Noise Control. Commercial, Industrial, and Environmental Products and Solutions.

Noise Control. Commercial, Industrial, and Environmental Products and Solutions. Noise Control Commercial, Industrial, and Environmental Products and Solutions www.kineticsnoise.com Commercial Duct Silencers Kinetics Noise Control offers the design and engineering assistance to integrate

More information

Ph: Fax Web: East Philadelphia Street Ontario, California USA

Ph: Fax Web: East Philadelphia Street Ontario, California USA TEST REPORT Ph: 909.472.4100 Fax 909.472.4243 Web: www.iapmo.org 5001 East Philadelphia Street Ontario, California 91761-2816 - USA Report Number: 1724-12001 Report Issued: July 27, 2012 Project No.: 20581

More information

Quality Standard for ACR Copper Tubes in LWC

Quality Standard for ACR Copper Tubes in LWC Quality Standard for ACR Copper Tubes in LWC Foreword cuproclima is a protected tradename for high-quality seamless copper tubes in levelwound coils (LWC) supplied to manufacturers of heat exchangers for

More information

DIVISION: METALS SECTION: STEEL DECKING REPORT HOLDER: EPIC METALS CORPORATION 11 TALBOT AVENUE RANKIN, PENNSYLVANIA 15104

DIVISION: METALS SECTION: STEEL DECKING REPORT HOLDER: EPIC METALS CORPORATION 11 TALBOT AVENUE RANKIN, PENNSYLVANIA 15104 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 2047 Reissued 07/207 This report is subject to renewal 07/209. DIVISION: 05 00 00

More information

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: FIBER-CEMENT SIDING REPORT HOLDER: EQUITONE

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: FIBER-CEMENT SIDING REPORT HOLDER: EQUITONE 0 Most Widely Accepted and Trusted ICC-ES Evaluation Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-3910 Issued 04/2017 This report is subject to renewal 04/2018. DIVISION: 07 00 00

More information

CHAPTER 26 PLASTIC SECTION BC 2601 SECTION BC 2603 GENERAL FOAM PLASTIC INSULATION

CHAPTER 26 PLASTIC SECTION BC 2601 SECTION BC 2603 GENERAL FOAM PLASTIC INSULATION CHAPTER 26 PLASTIC SECTION BC 2601 GENERAL 2601.1 Scope. These provisions shall govern the materials, design, application, construction and installation of foam plastic, foam plastic insulation, plastic

More information

Solar Keymark Network

Solar Keymark Network Solar Keymark Network Experience exchange circle of test labs and certifiers working according to the Solar Keymark scheme rules SKN_N0100.R3 List of Decisions Revision 3 Date: April 17 th, 2010 Preface:

More information

K-FLEX K-FONIK INDUSTRIAL

K-FLEX K-FONIK INDUSTRIAL J a n u a r y 2 0 1 3 K-FLEX K-FONIK INDUSTRIAL Sound & Thermal Insulation design compliant with ISO 15665 www.kflexenergy.com Flexible Elastomeric Foam layer INSULATING PIPING WITH K-FLEX SHEETS > FIRST

More information

Numerical Analysis of Solar Flat Plate Collector for Circular Pipe Configuration by using CFD

Numerical Analysis of Solar Flat Plate Collector for Circular Pipe Configuration by using CFD Numerical Analysis of Solar Flat Plate Collector for Circular Pipe Configuration by using CFD Ranjitha P 1, Somashekar V 2, Jamuna A B 3 1 Asst. Professor, Department of Aeronautical Engineering, Visvesvaraya

More information

Seawater corrosion resistant piping systems for large diameters up to 100 / 2.5 metres O.D.

Seawater corrosion resistant piping systems for large diameters up to 100 / 2.5 metres O.D. OSNA -10 Copper-Nickel Lined Pipes Seawater corrosion resistant piping systems for large diameters up to 100 / 2.5 metres O.D. KME Germany AG & Co. KG Copper-Nickel Lined Pipes [GB] Member of the KME Group

More information

Solar heating system monitoring at solarheatdata.eu. Key monitoring methods and main features of the website

Solar heating system monitoring at solarheatdata.eu. Key monitoring methods and main features of the website Solar heating system monitoring at solarheatdata.eu Key monitoring methods and main features of the website Table of Contents 1 Introduction... 2 2 Features of solarheatdata.eu... 2 2.1 Solar heating system

More information

Armorcoat 2 Mil Clear

Armorcoat 2 Mil Clear Armorcoat 2 Mil Clear % Transmittance 77 71 65 % Absorptance 12 19 20 % Reflectance 11 10 15 % Transmittance 85 84 77 % Reflectance exterior 13 12 19 % Reflectance interior 12 12 19 Emissivity.85.85.85

More information

B-02 THERMAL OIL HEATERS

B-02 THERMAL OIL HEATERS Guideline No.: B-02(201510) B-02 THERMAL OIL HEATERS Issued date: October 20,2015 China Classification Society Foreword: This Guide is a part of CCS Rules, which contains technical requirements, inspection

More information

Target Inline Flowmeter

Target Inline Flowmeter Principle of Operation Flow is measured in terms of dynamic force acting on a target (solid disk) in the flow stream. Hermetically sealed, bonded strain gages in a bridge circuit configuration mounted

More information

Aqua Clear Aqua Clear multi-lobal cross section of individual filaments has more micro-voids giving higher dirt holding capacity and lower resistance

Aqua Clear Aqua Clear multi-lobal cross section of individual filaments has more micro-voids giving higher dirt holding capacity and lower resistance Aqua Clear STRING-WOUND FILTER CARTRIDGES Free of extractables No leaching Twice the life of conventional cartridges Made from continuous filaments No media migration % Polypropylene Wide chemical compatibility

More information

Heat transfer intensification in heat exchangers of air source heat pumps

Heat transfer intensification in heat exchangers of air source heat pumps Heat transfer intensification in heat exchangers of air source heat pumps Dariusz Mikielewicz, Jarosław Mikielewicz, Piotr Doerffer 1. Introduction Air source heat pumps use air as a heat source to evaporate

More information

Dissimilar Metal Welds (DMW) in German LWR s. Design Types, Disbonding, NDT. W. Mayinger, K.J. Metzner E.ON Kernkraft, Hannover, Germany

Dissimilar Metal Welds (DMW) in German LWR s. Design Types, Disbonding, NDT. W. Mayinger, K.J. Metzner E.ON Kernkraft, Hannover, Germany Dissimilar Metal Welds (DMW) in German LWR s Design Types, Disbonding, NDT W. Mayinger, K.J. Metzner E.ON Kernkraft, Hannover, Germany 2 Scope Scope Flaws/Cracks in Dissimilar Metal Welds (DMW) 1. Interfacial

More information

EFFICIENCY ANALYSIS OF FLAT PLATE COLLECTORS FOR BUILDING FAÇADE INTEGRATION

EFFICIENCY ANALYSIS OF FLAT PLATE COLLECTORS FOR BUILDING FAÇADE INTEGRATION EFFICIENCY ANALYSIS OF FLAT PLATE COLLECTORS FOR BUILDING FAÇADE INTEGRATION Richard O Hegarty; Oliver Kinnane; Sarah McCormack. Dept of Civil, Structural and Environmental Engineering, Trinity College

More information

SOLAR DESALINATION TECHNOLOGY BRIEF

SOLAR DESALINATION TECHNOLOGY BRIEF ALPHA-OMEGA SOLAR DESALINATION TECHNOLOGY BRIEF ALPHA OMEGA ECOLOGICAL SOLUTIONS Athens Office: 8, R. Garibaldi & Sofroniskou str. Tel. +30.210.9228225 Email: info@alpha-omega.com.gr Page1of 8 ALPHA OMEGA

More information

Fenestration Energy Performance:

Fenestration Energy Performance: number 9 Builder Insight Fenestration Energy Performance: A Roadmap for Understanding Requirements for Residential Buildings in British Columbia Overview Energy performance requirements for windows, doors

More information

Continental Industries METER RISERS or FAX Visit

Continental Industries METER RISERS or FAX Visit Continental Industries METER RISERS 1-800-558-1373 or FAX 1-800-788-1668 Visit www.conind.com ABOUT US Our Company Continental Industries, headquartered in Tulsa, Oklahoma, was formed in 1958 and is today

More information

3M Fire Barrier Duct Wrap 615+ Product Data Sheet and Installation Guide (Condensed Version)

3M Fire Barrier Duct Wrap 615+ Product Data Sheet and Installation Guide (Condensed Version) M Fire Barrier Duct Wrap + Product Data Sheet and Installation Guide (Condensed Version) FIRE BARRIER UP TO Fire Protection HOUR FLEXIBLE WRAP GREASE & AIR DUCT Fire Protection. Product Description M Fire

More information

High Pressure Filter Assemblies

High Pressure Filter Assemblies High Pressure Filter Assemblies Up to 20,000 PSI (1378 bar) All stainless steel construction Stainless steel metal felt filter elements High Pressure T-Type Filter Assemblies Greater service life than

More information

Northpointe Renovation EPN #1701 F/A Project #17027 September 8, 2017

Northpointe Renovation EPN #1701 F/A Project #17027 September 8, 2017 SECTION 055213 - PIPE AND TUBE RAILINGS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

Evaluation of efficiency and collector time constant of a solar flat plate collector

Evaluation of efficiency and collector time constant of a solar flat plate collector Evaluation of efficiency and collector time constant of a solar flat plate collector Abhijit Devaraj 1, Abhishek Hiremath 2, Akshay R Patil 3, Krushik B N 4 Department of Mechanical Engineering, BMS College

More information