OG-100 ICC-SRCC TM CERTIFIED SOLAR COLLECTOR # D

Size: px
Start display at page:

Download "OG-100 ICC-SRCC TM CERTIFIED SOLAR COLLECTOR # D"

Transcription

1 accredited and EPA recognized Certification Body, in accordance with the SRCC OG-100 Certification Program, as defined in SRCC OG-100, Operating Guidelines and Minimum Standards for Certifying Solar Collectors. This award of certification is subject to all terms and conditions of the current OG-100 Program Agreement and the documents incorporated therein by reference. This document must be reproduced in its Climate -> Category (Ti-Ta) Kilowatt-hours (thermal) Per Panel Per Day High Radiation (6.3 kwh/m².day) Medium Radiation (4.7 kwh/m².day) COLLECTOR THERMAL PERFORMANCE RATINGS Low Radiation (3.1 kwh/m².day) Climate -> Category (Ti-Ta) Thousands of Btu Per Panel Per Day High Radiation (2000 Btu/ft².day) Medium Radiation (1500 Btu/ft².day) Low Radiation (1000 Btu/ft².day) A (-5 C) A (-9 F) B (5 C) B (9 F) C (20 C) C (36 F) D (50 C) D (90 F) E (80 C) E (144 F) TECHNICAL RESULTS Tested in accordance with: ISO Efficiency Equation [NOTE: Based on gross area and (P)=Ti-Ta] SI UNITS: η= (P/G) (P²/G) Y Intercept: Slope: W/m². C IP UNITS: η= (P/G) (P²/G) Y Intercept: Slope: Btu/hr.ft². F Incident Angle: θ Transverse IAM: Kτα Longitudinal IAM: Kτα COLLECTOR SPECIFICATIONS Gross Area: m² ft² Dry Weight: 41.3 kg 91.1 lb Net Aperture Area: m² ft² Fluid Capacity: 2.1 liter 0.6 gal REMARKS: Technical Director Print April 10, 2018 Page 1 of 5

2 ADDITIONAL INFORMATION (click here to return to the rating page) COLLECTOR TESTING INFORMATION Test Lab: Bodycote Test June 29, 2009 Test Report Number: Test Location: Test Fluid: Water Test Mass Flow Rate: kg/(s m²) lb/(hr ft²) Test Pressure: 1103 kpa 160 psi SOLAR COLLECTOR CONSTRUCTION DETAILS Header Enclosure: Gross Length: m Gross Width: m Gross Depth: Tube Bank: Gross Length: Gross Width: COLLECTOR MATERIALS Outer Cover: Other Enclosure back: Aluminum Back Insulation:, Inner Cover: None Enclosure side: Aluminum Side Insulation:, Absorber Description: Flow Pattern: Riser Tube: Stainless Steel Fin: Absorber Coating: Selective Tube to fin connection GLAZING Outer Cover Inner Cover Material: Other None Surface Characteristics: Thickness: 0.0 mm N/A Transmissivity: Gross Tube Length (uninstalled): m Diameter: m Tube Glazing to Header Enclosure Seal: Print April 10, 2018 Page 2 of 5

3 Reflector Shape: Reflector Material: ABSORBER Header Material: Header OD: Header Wall: Riser Tube Material: Stainless Steel Riser Tube OD: Riser Tube Wall Thickness: Fin Material: Fin Thickness: 0.00 mm Flow Pattern: Number of absorber tubes: Number of Flow Tubes / Heat Pipes: 12 Flow Tube to Fin Bond: Length of Flow Path: 0.00 m Riser to Fin/Plate Bond: 12 Tube / Heat Pipe Spacing: Length of Flow Path: 0.00 m INSULATION: Location Type Thickness Location Type Thickness Back Top Layer: Sides Inner Layer: Back Bottom Layer: Sides Outer Layer: Enclosure Fastening Methods: Header Enclosure: Power Output per Collector(W) [ Ti-Ta, G = 1000 W/m² ] Print April 10, 2018 Page 3 of 5

4 PRESSURE DROP Flow ΔP Flow ΔP ml/s Pa gpm in H₂ Print April 10, 2018 Page 4 of 5

5 ICC-SRCC OG-100 Certification Label The collectors listed in this certification must display the label below. The certification label must be permanently affixed to each collector in accordance with SRCC OG-100 program requirements. This product certified by the Solar Rating & Certification Corporation ICC-SRCC Certification Number: High Solar Radiation Climate Rating in Category C 9.41 kwh/day kbtu/day Print April 10, 2018 Page 5 of 5

Optimization of Thermosiphon Solar Water Heating systems working in a Mediterranean Environment of Cyprus

Optimization of Thermosiphon Solar Water Heating systems working in a Mediterranean Environment of Cyprus Archimedes Solar Energy Laboratory (ASEL) Optimization of Thermosiphon Solar Water Heating systems working in a Mediterranean Environment of Cyprus 7-8 October, Nicosia Cyprus Rafaela A. Agathokleous Solar

More information

Experimental Study of Sunearth Flat Plate Solar Collector

Experimental Study of Sunearth Flat Plate Solar Collector Experimental Study of Sunearth Flat Plate Solar Collector K.R. Anderson *1, S. Hill 2, C. Selerberg 3, E. Guiterez 4 1,2,3,4 Solar Thermal Alternative Renewable Energy Lab, Mechanical Engineering, California

More information

Solar Flat Plate Thermal Collector

Solar Flat Plate Thermal Collector Solar Flat Plate Thermal Collector 1 OBJECTIVE: Performance Study of Solar Flat Plate Thermal Collector Operation with Variation in Mass Flow Rate and Level of Radiation INTRODUCTION: Solar water heater

More information

G SERIES Solar Collectors

G SERIES Solar Collectors 2.47m (97-3/8") 2.38m (93-7/8") G SERIES Solar Collectors Thermo Dynamics Ltd. 101 Frazee Avenue Dartmouth, Nova Scotia Canada, B3B-1Z4 Tel: (902) 468-1001 Fax: (902) 468-1002 Email: solarinfo@thermo-dynamics.com

More information

Sir, We hereby place an order on you for the services as described below: Collector Area (m²) No. of samples

Sir, We hereby place an order on you for the services as described below: Collector Area (m²) No. of samples APPLICATION FORM SOLAR FLAT PLATE COLLECTOR (FPC) From: - Company (Please write complete Postal address) Sir, We hereby place an order on you for the services as described below: Sr. No. Description Collector

More information

ICC-SRCC LISTING. DIVISION: PLUMBING Section: Residential Solar Domestic Water Heater System

ICC-SRCC LISTING. DIVISION: PLUMBING Section: Residential Solar Domestic Water Heater System ICC-SRCC LISTING SRCC TM Solar Heating & Cooling Code & Standard Listing Program Listing Number: SRCC-16004 Effective Date: May 27, 2017 This listing is subject to re-examination in one year. www.solar-rating.org

More information

SUMMARY AND CONCLUSION

SUMMARY AND CONCLUSION 5 SUMMARY AND CONCLUSION Energy in the form of heat is required for diverse applications in various sectors including domestic, agricultural, commercial and industrial sectors. As there is a gap between

More information

Design Considerations for Flat Plate Solar Water Heater System

Design Considerations for Flat Plate Solar Water Heater System Design Considerations for Flat Plate Solar Water Heater System 1* P. P.Patil, 2 Dr.D.S.Deshmukh. 1* Assi. Prof., Mech. Engg. Department, SGDCOE Jalgaon.MS India 2 Professor, Mech. Engg. Department, SSBT

More information

ICC-SRCC LISTING. DIVISION: PLUMBING Section: Residential Solar Domestic Water Heater System

ICC-SRCC LISTING. DIVISION: PLUMBING Section: Residential Solar Domestic Water Heater System ICC-SRCC LISTING ICC-SRCC Solar Thermal Listing Program Listing Number: SRCC-16004 Effective Date: May 31, 2018 This listing is subject to re-examination in one year. www.solar-rating.org (888) 422-7233

More information

High Quality. UniPlate. Solar Collectors ENERGY SYSTEMS. Solartechnik Prüfung Forschung

High Quality. UniPlate. Solar Collectors ENERGY SYSTEMS. Solartechnik Prüfung Forschung High Quality UniPlate Solar Collectors ENERGY SYSTEMS Solartechnik Prüfung Forschung 10 n Solar energy has by far the highest theoretical potential of the earth s renewable energy sources. It is the most

More information

Performance Improvement in Solar Evacuated Glass Tube Collector

Performance Improvement in Solar Evacuated Glass Tube Collector Performance Improvement in Solar Evacuated Glass Tube Collector Amol Rao 1, Prof. Pankaj Jain 2, Ketan Patil 3, Shreyash Deshpande 4, Yogesh Dhondge 5 1, 2, 3, 4, 5, Jawahar Institute of Technology, India.

More information

Heat Exchanger activities at TWI SOLEGLASS Project Overview All glass Mid temperature Direct flow thermal solar vacuum tube

Heat Exchanger activities at TWI SOLEGLASS Project Overview All glass Mid temperature Direct flow thermal solar vacuum tube Heat Exchanger activities at TWI SOLEGLASS Project Overview All glass Mid temperature Direct flow thermal solar vacuum tube Maxime Mrovcak 20 th May 2014 Project Context Solar Thermal systems are rapidly

More information

ICC 901/SRCC xx Minimum Standards for Solar Thermal Collectors

ICC 901/SRCC xx Minimum Standards for Solar Thermal Collectors ICC 901/SRCC 100-20xx Minimum Standards for Solar Thermal Collectors October 2013 Page 1 TABLE OF CONTENTS CHAPTER 1 APPLICATION AND ADMINISTRATION Section 101 GENERAL 102 SCOPE 103 COMPLIANCE ALTERNATIVES

More information

Available online Journal of Scientific and Engineering Research, 2017, 4(1): Research Article

Available online   Journal of Scientific and Engineering Research, 2017, 4(1): Research Article Available online www.jsaer.com, 2017, 4(1):105-109 Research Article SSN: 2394-2630 CODEN(USA): JSERBR Design and Testing Parabolic Trough Solar Collector S. Abdelhady, M. Shaban, M. Fathy, A. Ahmed Aswan

More information

SRCC Standard ?? MINIMUM STANDARDS FOR SOLAR THERMAL COLLECTORS

SRCC Standard ?? MINIMUM STANDARDS FOR SOLAR THERMAL COLLECTORS SRCC Standard 100-2013-114-?? MINIMUM STANDARDS FOR SOLAR THERMAL COLLECTORS November 7, 2013???, 2014 20143 Solar Rating & Certification Corporation. All Rights Reserved. This document is the exclusive

More information

LAY OUT OF SYSTEMS High-flow and low-flow systems

LAY OUT OF SYSTEMS High-flow and low-flow systems LAY OUT OF SYSTEMS High-flow and low-flow systems Werner Weiss AEE - Institute for Sustainable Technologies (AEE INTEC) A-8200 Gleisdorf, Feldgasse 19 AUSTRIA Mode of Operation high-flow Kollektorfeld

More information

International Journal of Engineering Research & Science (IJOER) ISSN: [ ] [Vol-2, Issue-6, June- 2016]

International Journal of Engineering Research & Science (IJOER) ISSN: [ ] [Vol-2, Issue-6, June- 2016] International Journal of Engineering Research & Science (IJOER) ISSN: [2395-6992] [Vol-2, Issue-6, June- 216] Performance Evaluation of Solar Parabolic Trough Collector with Stainless Steel Sheet as a

More information

Simulation Performance, Solar Heat Gain Coefficient, Visible Transmittance and Condensation Resistance Calculation Report

Simulation Performance, Solar Heat Gain Coefficient, Visible Transmittance and Condensation Resistance Calculation Report Simulation Performance, Solar Heat Gain Coefficient, Visible Transmittance and Condensation Resistance Calculation Report REPORT NO: SIMULATION DATE: 11/18/11 REPORT DATE: 11/18/11 Client: Product Line:

More information

Passive House Northwest

Passive House Northwest Passive House Northwest AIA CEU Provider Window Workshop- A Window on the Future Course# 021518-phnw Daniel Haaland, RDH Building Science February 15th, 2018 1 Credit(s) earned on completion of this course

More information

Technology for Process Heat Applications. and Solar Field Optimization

Technology for Process Heat Applications. and Solar Field Optimization Technology for Process Heat Applications and Solar Field Optimization erfis PARABOLIC TROUGH Technical Data Sheet Parabolic Trough Collector Design Solar Field Engineering Construction Erection Fields

More information

Solar Hot Air Collectors. Rob Taisey Assured Solar Energy

Solar Hot Air Collectors. Rob Taisey Assured Solar Energy Solar Hot Air Collectors Rob Taisey Assured Solar Energy Program Outline Solar Basics overview: Passive; Active-PV, Solar Thermal Solar Air Heaters (SAH) Types (Glazed, Unglazed) Applications:Space heat,

More information

CPC EVACUATED TUBE COLLECTOR SYSTEMS FOR PROCESS HEAT UP TO 160 C

CPC EVACUATED TUBE COLLECTOR SYSTEMS FOR PROCESS HEAT UP TO 160 C CPC EVACUATED TUBE COLLECTOR SYSTEMS FOR PROCESS HEAT UP TO 6 C Rolf Meissner Ritter XL Solar GmbH e-mail: r.meissner@ritter-xl-solar.com Introduction Using water as heat transfer fluid CPC evacuated tube

More information

Bridging on Building Envelope Performance. A Whole Building Energy Perspective

Bridging on Building Envelope Performance. A Whole Building Energy Perspective The Effects of Thermal Bridging on Building Envelope Performance A Whole Building Energy Perspective Dave André PEng Dave André, P.Eng. January 2014 1 Thermal Bridging g Impact 2 Thermal Bridging Overview

More information

Performance Analysis of Glazed Liquid Photovoltaic-thermal Collector with Use of Detail Model

Performance Analysis of Glazed Liquid Photovoltaic-thermal Collector with Use of Detail Model Performance Analysis of Glazed Liquid Photovoltaic-thermal Collector with Use of Detail Model Nikola Pokorny 1,2, Tomas Matuska 1,2 1 CTU in Prague, Faculty of Mechanical Engineering, Department of Environmental

More information

Development and Validation of Flat-Plate Collector Testing Procedures

Development and Validation of Flat-Plate Collector Testing Procedures Development and Validation of Flat-Plate Collector Testing Procedures Report for September October, 2006 Focus on Energy (FOE) supports solar thermal systems that displace conventional fuels by offering

More information

Triple E Eligibility Criteria

Triple E Eligibility Criteria Triple E Eligibility Criteria Category: Heating and Electricity Provision Technology: Solar Thermal Collectors Solar thermal collectors are defined as renewable energy equipment which transforms solar

More information

SOLAR COLLECTORS TITANPOWER TM FLAT PLATE & THERMOPOWER TM EVACUATED TUBES

SOLAR COLLECTORS TITANPOWER TM FLAT PLATE & THERMOPOWER TM EVACUATED TUBES SOLAR COLLECTORS TITANPOWER TM FLAT PLATE & THERMOPOWER TM EVACUATED TUBES SUPERIOR PERFORMANCE SunMaxx solar collectors are among the best performing and most efficient in the solar thermal industry CUTTING-EDGE

More information

Experimental Investigation of a New Solar Flat Plate Collector

Experimental Investigation of a New Solar Flat Plate Collector Abstract Research Journal of Engineering Sciences ISSN 2278 9472 Experimental Investigation of a New Solar Flat Plate Collector Raj Thundil Karuppa R. 1, Pavan P. 2 and Reddy Rajeev D. 3, School of Mechanical

More information

ASSE International Product (Seal) Listing Program. ASSE Outdoor Enclosures for Fluid Conveying Components

ASSE International Product (Seal) Listing Program. ASSE Outdoor Enclosures for Fluid Conveying Components ASSE International Product (Seal) Listing Program ASSE 1060-2017 Outdoor Enclosures for Fluid Conveying Components Manufacturer: Contact Person: E-mail: Address: Laboratory: Laboratory File Number: Model

More information

Thermal Bridging and Whole Building Energy Performance

Thermal Bridging and Whole Building Energy Performance Thermal Bridging and Whole Building Energy Performance Steve Murray, P.Eng. PMP Morrison Hershfield May 8 & 9, 2013 1 Acknowledgments The real work for ASHRAE 1365 RP was done by others in MH s Vancouver

More information

Thermal Analysis of Solar Flat Plate Collector

Thermal Analysis of Solar Flat Plate Collector Thermal Analysis of Solar Flat Plate Collector # Yakoob Kolipak,Associate Professor, ME Dept, E-mail:yakoob.cjits @gmail.com # Kranthi Kumar Guduru,Assistant Professor,ME Dept, E-mail: kranthicjits1@gmail.com

More information

SYSTEM PACKAGES OR CUSTOMIZED CONFIGURATIONS

SYSTEM PACKAGES OR CUSTOMIZED CONFIGURATIONS A USA MANUFACTURER OF SOLAR THERMAL SYSTEMS Providing ADVANCED, RELIABLE TECHNOLOGIES OG for residential, industrial, commercial, institutional markets. SYSTEM PACKAGES OR CUSTOMIZED CONFIGURATIONS EVACUATED

More information

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ROOFING AND SIDING PANELS REPORT HOLDER: FOUR SEASONS BUILDING PRODUCTS, LLC

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ROOFING AND SIDING PANELS REPORT HOLDER: FOUR SEASONS BUILDING PRODUCTS, LLC 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 2229 Reissued 05/2018 This report is subject to renewal 05/2019. DIVISION: 07 00

More information

Comments: Select "Approximate Analysis" Diagnostic results from source areas are as follows:

Comments: Select Approximate Analysis Diagnostic results from source areas are as follows: FIN TEST PROBLEMS The non-proprietary test problems that have been used to validate fin analysis in INSTED are discussed in this section. You might need to consult the original sources of the various test

More information

U-Factor, Solar Heat Gain Coefficient, Visible Transmittance and Condensation Resistance Calculation Report

U-Factor, Solar Heat Gain Coefficient, Visible Transmittance and Condensation Resistance Calculation Report U-Factor, Solar Heat Gain Coefficient, Visible Transmittance and Condensation Resistance Calculation Report REPORT NO: SIMULATION DATE: 11/30/15 REPORT DATE: 11/30/15 Client: Product Line: Specification:

More information

K. All mechanical rooms shall be designed with a minimum 3-1/2 dropped floor.

K. All mechanical rooms shall be designed with a minimum 3-1/2 dropped floor. PART 1: GENERAL 1.01 Purpose: A. This standard is intended to provide useful information to the Professional Service Provider (PSP) to establish a basis of design. The responsibility of the engineer is

More information

New Efficient Water Heating Technologies What do they mean for solar thermal? ACEEE Hot Water Forum Future of Solar Water Heating March 21, 2018

New Efficient Water Heating Technologies What do they mean for solar thermal? ACEEE Hot Water Forum Future of Solar Water Heating March 21, 2018 New Efficient Water Heating Technologies What do they mean for solar thermal? ACEEE Hot Water Forum Future of Solar Water Heating March 21, 2018 What is ICC-ES? ICC-ES evaluates products using codes and

More information

Unitised Curtain Wall Beaded

Unitised Curtain Wall Beaded Unitised Curtain Wall Beaded Glazed Frame Unitised Curtain Wall Reference Brand: Sapa Building System Elegance 72 GF GENERAL DESCRIPTION Unitised curtain wall system using glazing beads for glass retention.

More information

Simulation Performance, Solar Heat Gain Coefficient, Visible Transmittance and Condensation Resistance Calculation Report REPORT NO: DRAFT

Simulation Performance, Solar Heat Gain Coefficient, Visible Transmittance and Condensation Resistance Calculation Report REPORT NO: DRAFT Simulation Performance, Solar Heat Gain Coefficient, Visible Transmittance and Condensation Resistance Calculation Report REPORT NO: SIMULATION DATE: 08/06/10 REPORT DATE: 08/06/10 Client: Product Line:

More information

David Baker Piping Technology & Products. NIA s 62nd Annual Convention Sheraton Grand at Wild Horse Pass March 29 April 1, 2017

David Baker Piping Technology & Products. NIA s 62nd Annual Convention Sheraton Grand at Wild Horse Pass March 29 April 1, 2017 David Baker Piping Technology & Products NIA s 62nd Annual Convention Sheraton Grand at Wild Horse Pass March 29 April 1, 2017 Piping Technology & Products, Inc. Piping Technology & Products, Inc. (PT&P)

More information

Design and Fabrication of Parabolic Trough Solar Water Heater for Hot Water Generation

Design and Fabrication of Parabolic Trough Solar Water Heater for Hot Water Generation Design and Fabrication of Parabolic Trough Solar Water Heater for Hot Water Generation Santosh Kumar Singh 1 Arvind Kumar Singh 2 and Santosh Kumar Yadav 3 1 asst. prof. and Corresponding Author, 2 assistant

More information

Solar Process Heat for Production and Advanced Applications. Comparison of process heat collectors with respect to technical and economic conditions

Solar Process Heat for Production and Advanced Applications. Comparison of process heat collectors with respect to technical and economic conditions Solar IEA SHC Task 49 SolarPACES Annex IV Solar Process Heat for Production and Advanced Applications Comparison of process heat collectors with respect to technical and economic conditions Technical Report

More information

Calculation and Fabrication of a Solar Flat Plate Collector Efficiency using Mild Steel as Absorber Plate

Calculation and Fabrication of a Solar Flat Plate Collector Efficiency using Mild Steel as Absorber Plate IJSTE - International Journal of Science Technology & Engineering Volume 3 Issue 08 February 2017 ISSN (online): 2349-784X Calculation and Fabrication of a Solar Flat Plate Collector Efficiency using Mild

More information

Solar Thermal Systems for Residential Homes

Solar Thermal Systems for Residential Homes Solar Thermal Systems for Residential Homes Lingying Zhao, Professor Braydi McPherson, Student Assistant Dept. of Food, Agricultural and Biological Engineering The Ohio State University 1 Questions: What

More information

Performance Evaluation of Solar Parabolic Trough for Cloths Laundry application

Performance Evaluation of Solar Parabolic Trough for Cloths Laundry application Performance Evaluation of Solar Parabolic Trough for Cloths Laundry application Shubham Gupta*, Prof. R. S. Mishra Department of Mechanical Engineering Delhi Technological University, Delhi-110042. guptashubham@outlook.in,

More information

THE COMPLETE POLYETHYLENE INSULATION PACKAGE FOR EFFECTIVE ENERGY SAVING AND ACOUSTIC PROTECTION

THE COMPLETE POLYETHYLENE INSULATION PACKAGE FOR EFFECTIVE ENERGY SAVING AND ACOUSTIC PROTECTION THE COMPLETE POLYETHYLENE INSULATION PACKAGE FOR EFFECTIVE ENERGY SAVING AND ACOUSTIC PROTECTION Powered by TCPDF (www.tcpdf.org) Complete range of PE thermal and acoustic insulation products Meets European

More information

Renewable energy from the sun Daikin solar thermal systems for the installer

Renewable energy from the sun Daikin solar thermal systems for the installer Renewable energy from the sun Daikin solar thermal systems for the installer Renewable energy from the sun Solar Thermal systems Why choose Daikin Solar? Your customer requires a solar thermal system:

More information

UNIT FOUR SOLAR COLLECTORS

UNIT FOUR SOLAR COLLECTORS ME 476 Solar Energy UNIT FOUR SOLAR COLLECTORS Concentrating Collectors Concentrating Collectors 2 For many applications it is desirable to deliver energy at temperatures higher than those possible with

More information

SOLTRAIN II SOLAR WATER HEATING SYSTEM TEST AND DEMONSTRATION FACILITY

SOLTRAIN II SOLAR WATER HEATING SYSTEM TEST AND DEMONSTRATION FACILITY SASEC2015 Third Southern African Solar Energy Conference 11 13 May 2015 Kruger National Park, South Africa SOLTRAIN II SOLAR WATER HEATING SYSTEM TEST AND DEMONSTRATION FACILITY Silinga C.* *Author for

More information

State of New Hampshire Public Utilities Commission 21 S. Fruit Street, Suite 10, Concord, NH

State of New Hampshire Public Utilities Commission 21 S. Fruit Street, Suite 10, Concord, NH State of New Hampshire Public Utilities Commission 21 S. Fruit Street, Suite 10, Concord, NH 03301-2429 REVISED 5-3-18 APPLICATION FORM FOR RENEWABLE ENERGY SOURCE ELIGIBILITY FOR CLASS I THERMAL SOURCES

More information

ECOTOP VF-HF. high efficiency glazed flat-plate solar collectors > MAXIMUM MODULARITY > SIMPLIFIED INSTALLATION

ECOTOP VF-HF. high efficiency glazed flat-plate solar collectors > MAXIMUM MODULARITY > SIMPLIFIED INSTALLATION p r o d u c t MADE IN ITALY ECOTOP VF-HF high efficiency glazed flat-plate solar collectors VF 2.8 VF 2.3 HF 2.3 VF 2.0 > MAXIMUM MODULARITY > SIMPLIFIED INSTALLATION > ASSEMBLY ON THE ROOF OR FLUSH WITH

More information

LT/ArmaFlex. Industrial INSULATION FOR THE OIL AND GAS INDUSTRY. High density industrial grade FEF installation

LT/ArmaFlex. Industrial INSULATION FOR THE OIL AND GAS INDUSTRY. High density industrial grade FEF installation INSULATION FOR THE OIL AND GAS INDUSTRY LT/ArmaFlex Industrial High density industrial grade FEF installation // Built-in water vapour barrier mitigates risk of corrosion under insulation (CUI) // Low

More information

Draft proposals for Test methods for close-coupled solar water heating systems - Reliability and safety

Draft proposals for Test methods for close-coupled solar water heating systems - Reliability and safety IEA/SHC Task 57, Subtask B Draft proposals for new test procedures B4: Final Draft Draft proposals for Test methods for close-coupled solar water heating systems - Reliability and safety HE Zinian Beijing

More information

Dimensioning a small-sized PTC solar field for heating and cooling of a hotel in Almería (Spain)

Dimensioning a small-sized PTC solar field for heating and cooling of a hotel in Almería (Spain) Available online at www.sciencedirect.com Energy Procedia 30 (2012 ) 967 973 SHC 2012 Dimensioning a small-sized PTC solar field for heating and cooling of a hotel in Almería (Spain) Manuel Quirante a,

More information

ENERGY STAR Qualifying Criteria for Residential Windows, Doors, and Skylights Sold in Canada Version 3.0 October 1, 2010

ENERGY STAR Qualifying Criteria for Residential Windows, Doors, and Skylights Sold in Canada Version 3.0 October 1, 2010 ENERGY STAR Qualifying Criteria for Residential Windows, Doors, and Skylights Sold in Canada Below is the product criteria for ENERGY STAR qualified residential windows, doors, and skylights sold in Canada

More information

Efficiencies of flat plate solar collectors at different flow rates

Efficiencies of flat plate solar collectors at different flow rates Available online at www.sciencedirect.com Energy Procedia 30 (01 ) 65 7 SHC 01 Efficiencies of flat plate solar collectors at different flow rates Ziqian Chen*, a Simon Furbo, Bengt Perers, Jianhua Fan,

More information

BASIC EUROPEAN GLAZED COLLECTORS & SOLAR DOMESTIC

BASIC EUROPEAN GLAZED COLLECTORS & SOLAR DOMESTIC ISO 98061 ISO 98O62 ISO 9459-2 BASIC EUROPEAN AND INTERNATIONAL STANDARDS ON SOLAR THERMAL GLAZED COLLECTORS & SOLAR DOMESTIC HOT WATER SYSTEMS A brief review addressed to: Manufacturers, Retailers, Promoters,

More information

EXPERIMENTAL STUDY ON SOLAR HEATING BY NATURAL HEAT CONVECTION AND RADIATION

EXPERIMENTAL STUDY ON SOLAR HEATING BY NATURAL HEAT CONVECTION AND RADIATION International Journal of Recent Advances in Mechanical Engineering (IJMECH) Vol., No.3/, November 17 EXPERIMENTAL STUDY ON SOLAR HEATING BY NATURAL HEAT CONVECTION AND RADIATION SeifA. Ahmed Mechanical

More information

SunWave Smoke Vent. Product Information. Description: Selection Information: Smoke Vents (Acrylic and Polycarbonate): Method of Application: Storage:

SunWave Smoke Vent. Product Information. Description: Selection Information: Smoke Vents (Acrylic and Polycarbonate): Method of Application: Storage: Item Description Smoke Vent Product Information Description: Smoke Vents (Acrylic) provide a double glazed, 100% Impact Modified 0.181" (4.6 mm) outer lens and a 50% Impact Modified 0.120" (3 mm) inside

More information

Exergy analysis of a flat plate solar collector

Exergy analysis of a flat plate solar collector Exergy analysis of a flat plate solar collector Sunil Chamoli GRDIMT Dehradun, Uttarakhand, India Abstract In this study, exergetic performance analysis of flat plate solar collector has been carried out

More information

Guidance page for practical work 1: modeling of a thermodynamic solar plant

Guidance page for practical work 1: modeling of a thermodynamic solar plant Guidance page for practical work 1: modeling of a thermodynamic solar plant 1) Objectives of the practical work The project objective is to study the operation of thermodynamic solar plants, to show how

More information

Hot water persons. Map section

Hot water persons. Map section Project Hot water 4-160 persons Location of the system Rapperswil SG Longitude: 8.82 Latitude: 47.23 Elevation: 417 m Map section "Current report item is not supported in this report format." This report

More information

Application Note AN 84/01. Pressure Transducer Temperature. Isolation Using Tubing. (Steady State Condition)

Application Note AN 84/01. Pressure Transducer Temperature. Isolation Using Tubing. (Steady State Condition) Application Note AN 84/01 Pressure Transducer Temperature Isolation Using Tubing (Steady State Condition) Revised August 19, 2002 Adam Kane Introduction Pressure Transducer Temperature Isolation Using

More information

DESIGN AND EXPERIMENT OF PARABOLIC TROUGH COLLECTOR WITH NORTH-SOUTH ORIENTATION

DESIGN AND EXPERIMENT OF PARABOLIC TROUGH COLLECTOR WITH NORTH-SOUTH ORIENTATION DESIGN AND EXPERIMENT OF PARABOLIC TROUGH COLLECTOR WITH NORTH-SOUTH ORIENTATION Mr. Shailesh Prajapati 1 and Mr. Dip Shah 2 1,2 Assistant Proffesor,Mechanical Enginnering Department,Institute of Technolgy

More information

SECTION SLOPED TRANSLUCENT METAL SKYLIGHT SYSTEM

SECTION SLOPED TRANSLUCENT METAL SKYLIGHT SYSTEM PART 1- GENERAL 1.1 SUMMARY A. Section Includes: SECTION 084523 - SLOPED TRANSLUCENT METAL SKYLIGHT SYSTEM 1. Flat factory prefabricated structural insulated translucent sandwich panels; with glazed endwalls.

More information

SOLAR DESALINATION AUGMENTED WITH EVACUATED-TUBE COLLECTOR

SOLAR DESALINATION AUGMENTED WITH EVACUATED-TUBE COLLECTOR SOLAR DESALINATION AUGMENTED WITH EVACUATED-TUBE COLLECTOR BADRAN, ALI A 1, MOHAMMAD DEYAB 2, ALRAYAN AHMAD 3, ABDALLAH SAEED 4 AND AHMED MUHANNA 5 1 Department of Mechanical Engineering, Philadelphia

More information

Thermal Analyses on Solar Collectors with Nano Carbon Coated Absorbers

Thermal Analyses on Solar Collectors with Nano Carbon Coated Absorbers Thermal Analyses on Solar Collectors with Nano Carbon Coated Absorbers Abstract P.H.Sudharlin Paul* 1, R.V.Jeba Rajasekhar 2 1 Department of Physics, St.Alphonsa College of Arts & Science, Karinkal, Kanyakumari

More information

Solar Calculations for the Raseiniai District Heating Plant

Solar Calculations for the Raseiniai District Heating Plant Solar Calculations for the Raseiniai District Heating Plant Linn Laurberg Jensen PlanEnergi E-mail: llj@planenergi.dk Tel.: + 45 9682 0450 Quality assured by Daniel Trier E-mail: dt@planenergi.dk Tel.:

More information

Continental J. Engineering Sciences 6 (1): 24-30, 2011 Wilolud Journals, 2011 ` Printed in Nigeria

Continental J. Engineering Sciences 6 (1): 24-30, 2011 Wilolud Journals, 2011 ` Printed in Nigeria Continental J. Engineering Sciences 6 (1): 24-30, 2011 Wilolud Journals, 2011 ` Printed in Nigeria ISSN: 2141-4068 http:/ //www.wiloludjournal.com SOLAR COLLECTOR EFFFICIENCY: Analysis and Application

More information

Solar desalination of seawater using a single-basin single sloped solar still with a parabolic concentrator

Solar desalination of seawater using a single-basin single sloped solar still with a parabolic concentrator Solar desalination of seawater using a single-basin single sloped solar still with a parabolic concentrator Deepak.S.A 1, Sagar Shetty 2, Soyal Kumar 2, Siddesha.K.M 3 1Assistant Professor, Dept. of Mechanical

More information

Thermal Analysis of Solar Flat Plate Collector Using CFD

Thermal Analysis of Solar Flat Plate Collector Using CFD Thermal Analysis of Solar Flat Plate Collector Using CFD 1 Mohammed Abdul Junaid, 2 Mohammed Nazimuddin, 3 Mohd Arifuddin, 4 Mohammed Faisal Asst. Prof, Mechanical Engg Dept. Lords Institute of Engg &

More information

Numerical Study on the Characteristics of a Specially Designed Rectangular Tube Absorber Photovoltaic Thermal Collector (PVT)

Numerical Study on the Characteristics of a Specially Designed Rectangular Tube Absorber Photovoltaic Thermal Collector (PVT) Numerical Study on the Characteristics of a Specially Designed Rectangular Tube Absorber Photovoltaic Thermal Collector (PVT) Ali Najah Al-Shamani 1,2*, Sohif Mat 1, M. H. Ruslan 1, Azher M. Abed 1, K.

More information

THERMAL SOLUTIONS HIGH FINNED TUBES GEWA-H, GEWA-HB

THERMAL SOLUTIONS HIGH FINNED TUBES GEWA-H, GEWA-HB THERMAL SOLUTIONS HIGH FINNED TUBES GEWA-H, GEWA-HB HIGH FINNED TUBES GEWA-H, GEWA-HB APPLICATIONS GEWA-H and GEWA-HB high finned tubes are made of aluminium alloys or copper and copper alloys. They are

More information

Performance Analysis of Evacuated Tube Heat Pipe Solar Water Heating System using Nanofluid coupled with parabolic Trough Concentrator

Performance Analysis of Evacuated Tube Heat Pipe Solar Water Heating System using Nanofluid coupled with parabolic Trough Concentrator IJSRD - International Journal for Scientific Research & Development Vol. 4, Issue 10, 2016 ISSN (online): 2321-0613 Performance Analysis of Evacuated Tube Heat Pipe Solar Water Heating System using Nanofluid

More information

Curtain Wall Stick System (Capped)

Curtain Wall Stick System (Capped) Curtain Wall Stick System (Capped) Stick Construction Capped Curtain Wall Reference Brand: Sapa Building System Elegance 52 ST GENERAL DESCRIPTION Grid based thermally insulated curtain wall system with

More information

Medium temperature solar thermal collector with an internally integrated CPC

Medium temperature solar thermal collector with an internally integrated CPC Ahmad Mojiri Medium temperature solar thermal collector with an internally integrated CPC Ahmad Mojiri, Cameron Stanley, David Rodriguez-Sanchez and Gary Rosengarten RMIT University, 115 Queensberry St.,

More information

ROOFS ROOFS WALLS FLOORS. Energy efficiency for constructions... Always environment-friendly...

ROOFS ROOFS WALLS FLOORS. Energy efficiency for constructions... Always environment-friendly... PRODUCT CATALOG Energy efficiency for constructions... Always environment-friendly... www.prodexcr.com CONSTRUCTION AREA REFLECTIVE THERMAL INSULATION AD AD= ALUMINUM + ALUMINUM 0,39; 0,19; and 0,11 in

More information

An experimental investigation on the effect of ferrofluids on the efficiency of novel parabolic trough solar collector under laminar flow conditions

An experimental investigation on the effect of ferrofluids on the efficiency of novel parabolic trough solar collector under laminar flow conditions An experimental investigation on the effect of ferrofluids on the efficiency of novel parabolic trough solar collector under laminar flow conditions Mustafa Alsaady, Yuying Yan, Rabah Boukhanouf Faculty

More information

Computational Study of Hybrid Water Heater with Evacuated Glass Tube Solar Collector and Rice Husk Combustion

Computational Study of Hybrid Water Heater with Evacuated Glass Tube Solar Collector and Rice Husk Combustion Energy Research Journal 1 (2): 182-188, 2010 ISSN 1949-0151 2010 Science Publications Computational Study of Hybrid Water Heater with Evacuated Glass Tube Solar Collector and Rice Husk Combustion Piyanun

More information

Originally Issued: 12/12/2014 Revised: 12/29/2017 Valid Through: 12/29/2018

Originally Issued: 12/12/2014 Revised: 12/29/2017 Valid Through: 12/29/2018 Originally Issued: 12/12/2014 Revised: 12/29/2017 Valid Through: 12/29/2018 TK Products A Division of Sierra Corporation TK-HYDROMAX 2001 SB DAMPPROOF COATING, TK-HYDROMAX 2002 SB FOUNDATION WATERPROOF

More information

AR No. # Solar Thermal. Assessment Recommendation Savings Summary Source. Cost Savings Natural Gas. $984 * 1 MMBtu = 1,000,000 Btu

AR No. # Solar Thermal. Assessment Recommendation Savings Summary Source. Cost Savings Natural Gas. $984 * 1 MMBtu = 1,000,000 Btu AR No. # Solar Thermal Recommendation We recommend installing a solar thermal array on the building roof. This will provide an alternative source for 9.8% of the facilities energy consumption and reduce

More information

REPORT HOLDER: UNITED DURALUME PRODUCTS, INC. EVALUATION SUBJECT: DURACOOL COMPOSITE STRUCTURAL INSULATED PANELS

REPORT HOLDER: UNITED DURALUME PRODUCTS, INC. EVALUATION SUBJECT: DURACOOL COMPOSITE STRUCTURAL INSULATED PANELS 0 ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org Most Widely Accepted and Trusted ESR 3779 Reissued 01/2017 Revised 10/2018 This report is subject to renewal 01/2019.

More information

KOMBI PVA KOMBI PVA 1 CC

KOMBI PVA KOMBI PVA 1 CC KOMBI PVA ** Radius of bend Max. supply pressure *D= Ø internal nominal Flame retardant (categoria II) - 10 C +120 C 0 Pa PVC/ALUMINIUM combined flexible duct that combines the high mechanical resistance

More information

Solar Keymark Network

Solar Keymark Network Solar Keymark Network Experience exchange circle of test labs and certifiers working according to the Solar Keymark scheme rules SKN_N0100.R2 List of Decisions Revision 2 Date: September 11 th, 2009 Preface:

More information

PERFORMANCE ANALYSIS OF EVACUATED TUBE HEAT PIPE SOLAR WATER HEATING SYSTEM USING COPPER OXIDE NANOFLUIDS

PERFORMANCE ANALYSIS OF EVACUATED TUBE HEAT PIPE SOLAR WATER HEATING SYSTEM USING COPPER OXIDE NANOFLUIDS PERFORMANCE ANALYSIS OF EVACUATED TUBE HEAT PIPE SOLAR WATER HEATING SYSTEM USING COPPER OXIDE NANOFLUIDS Sumedh S. Jagtap Jagdish D. Irale Dhiraj R. Bulkunde Palash A. Pandilwar Amirhussain R. Ansari

More information

Break it, or Lose it: Thermal Bridging in Building Envelopes

Break it, or Lose it: Thermal Bridging in Building Envelopes Break it, or Lose it: Thermal Bridging in Building Envelopes NESEA BuildingEnergy 16 March 9, 2016 INTRODUCTION Learning Objectives 1. Learn the significance that thermal bridges can have on decreasing

More information

Vessfire Simulation Report. Rupture summary No ruptures occurred. Case Definition. Vessel 23-VG02A. Report generated:

Vessfire Simulation Report. Rupture summary No ruptures occurred. Case Definition. Vessel 23-VG02A. Report generated: Vessfire Simulation Report Report generated: 21.1.214 13:8:17 Rupture summary No ruptures occurred. Case Definition Vessel 23-VG2A Flame: Longitudinal start: 45 % Longitudinal end: 55 % Angle from top:

More information

AR No. # - Solar Thermal

AR No. # - Solar Thermal AR No. # - Solar Thermal Recommendation We recommend installing a solar thermal array on the building roof. This will provide an alternative source for 10% of the facilities energy consumption and reduce

More information

SunWave Smoke Vent. Product Information. Description: Selection Information: Smoke Vents (Acrylic and Polycarbonate): Method of Application: Storage:

SunWave Smoke Vent. Product Information. Description: Selection Information: Smoke Vents (Acrylic and Polycarbonate): Method of Application: Storage: Item Description Smoke Vent Product Information Description: Smoke Vents (Acrylic) provide a double glazed, 100% Impact Modified 0.181" outer lens and a 50% Impact Modified 0.120" inside lens that is hail

More information

SECTION TUBULAR DAYLIGHTING DEVICE. Display hidden notes to specifier. (Don't know how? Click Here)

SECTION TUBULAR DAYLIGHTING DEVICE. Display hidden notes to specifier. (Don't know how? Click Here) SECTION 08625 TUBULAR DAYLIGHTING DEVICE Display hidden notes to specifier. (Don't know how? Click Here) PART 1 GENERAL 1.1 SECTION INCLUDES A. Tubular daylighting device, consisting of roof dome, reflective

More information

ELASTOMER- METAL- ABSORBER - DEVELOPMENT AND APPLICATION

ELASTOMER- METAL- ABSORBER - DEVELOPMENT AND APPLICATION ELASTOMER- METAL- ABSORBER - DEVELOPMENT AND APPLICATION Bernd Bartelsen, Gunter Rockendorf Institut für Solarenergieforschung GmbH, Am Ohrberg, D-386 Emmerthal, Germany, Tel. +49 ()55/ 999-522, Fax -5

More information

RHM80. High Flow Coriolis Mass Flow Meter. Features. Applications. Benefits

RHM80. High Flow Coriolis Mass Flow Meter. Features. Applications. Benefits RHM80 High Flow Coriolis Mass Flow Meter Features Standard pressure ratings up to 341 bar (4946 psi) Temperature ratings from -196 to 350 C (-320 to 662 F) Mass flow uncertainty down to 0.15% Density uncertainty

More information

SunMaxxTM Information Guide: Evacuated Tube Solar Collectors

SunMaxxTM Information Guide: Evacuated Tube Solar Collectors SunMaxxTM Information Guide: Evacuated Tube Solar Collectors P: 877.SUNMAXX / 888.SOLAR.11 www.siliconsolar.com / www.sunmaxxsolar.com Silicon Solar Inc Innovative Solar Solutions SunMaxxTM Information

More information

Specific CEN Keymark Scheme Rules for Solar Thermal Products

Specific CEN Keymark Scheme Rules for Solar Thermal Products SKN_N0106.R30 Specific CEN Keymark Scheme Rules for Solar Thermal Products 2017-04-07, Jan Erik Nielsen Page 1 of 33 Contents 1 DEFINITION OF SCOPE 5 1.1 Products covered by the scheme 5 1.2 List of European

More information

RHM60. Coriolis Mass Flow Meter with Uncompromising Performance. Features. Applications. Benefits

RHM60. Coriolis Mass Flow Meter with Uncompromising Performance. Features. Applications. Benefits RHM60 Coriolis Mass Flow Meter with Uncompromising Performance Features Standard pressure ratings up to 490 bar (7107 psi) Temperature ratings from -196 to 350 C (-320 to 662 F) Mass flow uncertainty down

More information

Balancing High Strength Tubing Selection and Cost in Hydraulic System Design IFPE 2014

Balancing High Strength Tubing Selection and Cost in Hydraulic System Design IFPE 2014 Balancing High Strength Tubing Selection and Cost in Hydraulic System Design IFPE 2014 Objectives Review the development of High Strength Steels and how that relates to hydraulic tubing development Explore

More information

Baltimore County Detention Center Expansion Towson, Maryland

Baltimore County Detention Center Expansion Towson, Maryland V. Active Solar System Introduction After the energy crises of the 1970s and the subsequent increases in the cost of petroleumbased fuels, interest in active solar energy systems surged. Thousands of active

More information