MANUAL for Engineered Wood Construction 2015 EDITION

Size: px
Start display at page:

Download "MANUAL for Engineered Wood Construction 2015 EDITION"

Transcription

1 By downloading this file to your computer, you are accepting and agreeing to the terms of AWC s end-user license agreement (EULA), which may be viewed here: End User License Agreement. Copyright infringement is a violation of federal law subject to criminal and civil penalties. MANUAL for Engineered Wood Construction 2015 EDITION

2 Updates and Errata While every precaution has been taken to ensure the accuracy of this document, errors may have occurred during development. Updates or Errata are posted to the American Wood Council website at Technical inquiries may be addressed to The American Wood Council (AWC) is the voice of North American traditional and engineered wood products. From a renewable resource that absorbs and sequesters carbon, the wood products industry makes products that are essential to everyday life. AWC s engineers, technologists, scientists, and building code experts develop state-of-the-art engineering data, technology, and standards on structural wood products for use by design professionals, building officials, and wood products manufacturers to assure the safe and efficient design and use of wood structural components.

3 i MANUAL FOR ENGINEERED WOOD CONSTRUCTION MANUAL for Engineered Wood Construction 2015 EDITION Copyright 2016 American Wood Council

4 ii MANUAL FOR ENGINEERED WOOD CONSTRUCTION Manual for Engineered Wood Construction 2015 Edition First Web Version: March 2016 ISBN Copyright 2016 by American Wood Council All rights reserved. No part of this publication may be reproduced, distributed, or transmitted in any form or by any means, including, without limitation, electronic, optical, or mechanical means (by way of example and not limitation, photocopying, or recording by or in an information storage retrieval system) without express written permission of the American Wood Council. For information on permission to copy material, please contact: Copyright Permission American Wood Council 222 Catoctin Circle, SE, Suite 201 Leesburg, VA

5 MANUAL FOR ENGINEERED WOOD CONSTRUCTION iii FOREWORD This Manual for Engineered Wood Construction (Manual) provides guidance for design of most woodbased structural products used in the construction of wood buildings. This Manual is intended for use with the Wood Design Package which includes the following documents: ANSI/AWC NDS-2015 National Design Specification (NDS ) for Wood Construction with Commentary, NDS Supplement Design Values for Wood Construction, 2015 Edition, ANSI/AWC SDPWS-2015 Special Design Provisions for Wind and Seismic (SDPWS) with Commentary, The American Wood Council (AWC) has developed this manual for design professionals. AWC and its predecessor organizations have provided engineering design information to users of structural wood products for over 75 years, first in the form of the Wood Structural Design Data series and then in the National Design Specification (NDS) for Wood Construction. It is intended that this document be used in conjunction with competent engineering design, accurate fabrication, and adequate supervision of construction. AWC does not assume any responsibility for errors or omissions in the document, nor for engineering designs, plans, or construction prepared from it. Those using this document assume all liability arising from its use. The design of engineered structures is within the scope of expertise of licensed engineers, architects, or other licensed professionals for applications to a particular structure. American Wood Council

6 iv MANUAL FOR ENGINEERED WOOD CONSTRUCTION

7 MANUAL FOR ENGINEERED WOOD CONSTRUCTION v TABLE OF CONTENTS Part/Title Page Part/Title Page M1: GENERAL REQUIREMENTS FOR STRUCTURAL DESIGN... 1 M1.1 Products Covered in This Manual M1.2 General Requirements M1.3 Design Procedures M2: DESIGN VALUES FOR STRUCTURAL MEMBERS... 3 M2.1 General Information M2.2 Reference Design Values M2.3 Adjustment of Reference Design Values M3: DESIGN PROVISIONS AND EQUATIONS... 5 M3.1 General M3.2 Bending Members - General M3.3 Bending Members - Flexure M3.4 Bending Members - Shear M3.5 Bending Members - Deflection M3.6 Compression Members M3.7 Solid Columns M3.8 Tension Members M3.9 Combined Bending and Axial Loading M3.10 Design for Bearing M4: SAWN LUMBER...11 M4.1 General M4.2 Reference Design Values M4.3 Adjustment of Reference Design Values M4.4 Special Design Considerations M5: STRUCTURAL GLUED LAMINATED TIMBER M5.1 General M5.2 Reference Design Values M5.3 Adjustment of Reference Design Values M5.4 Special Design Considerations M6: ROUND TIMBER POLES AND PILES...23 M6.1 General M6.2 Reference Design Values M6.3 Adjustment of Reference Design Values M6.4 Special Design Considerations M7: PREFABRICATED WOOD I-JOISTS M7.1 General M7.2 Reference Design Values M7.3 Adjustment of Reference Design Values M7.4 Special Design Considerations M8: STRUCTURAL COMPOSITE LUMBER...43 M8.1 General M8.2 Reference Design Values M8.3 Adjustment of Reference Design Values M8.4 Special Design Considerations M9: WOOD STRUCTURAL PANELS...49 M9.1 General M9.2 Reference Design Values M9.3 Adjustment of Reference Design Values M9.4 Design Considerations M10: CROSS-LAMINATED TIMBER...59 M10.1 General M10.2 Reference Design Values M10.3 Adjustment of Reference Design Values M10.4 Design Considerations M11: MECHANICAL CONNECTIONS...65 M11.1 General M11.2 Reference Design Values M11.3 Adjustment of Reference Design Values M11.4 Typical Connection Details M11.5 Pre-Engineered Metal Connectors M12: DOWEL- TYPE FASTENERS...81 M12.1 General M12.2 Reference Withdrawal Design Values M12.3 Reference Lateral Design Values M12.4 Combined Lateral and Withdrawal Loads M12.5 Adjustment of Reference Design Values M12.6 Multiple Fasteners

8 vi MANUAL FOR ENGINEERED WOOD CONSTRUCTION Part/Title Page Part/Title Page M13: SPLIT RING AND SHEAR PLATE CONNECTORS...85 M13.1 General M13.2 Reference Design Values M13.3 Placement of Split Ring and Shear Plate Connectors M14: TIMBER RIVETS...87 M14.1 General M14.2 Reference Design Values M14.3 Placement of Timber Rivets LIST OF TABLES M4.3-1 M4.4-1 Applicability of Adjustment Factors for Sawn Lumber Approximate Moisture and Thermal Dimensional Changes M4.4-2 Coefficient of Moisture Expansion, e ME, and Fiber Saturation Point, FSP, for Solid Woods M4.4-3 M5.1-1 M5.3-1 M5.4-1 M6.3-1 M7.3-1 M8.3-1 Coefficient of Thermal Expansion, e TE, for Solid Woods Economical Spans for Structural Glued Laminated Timber Framing Systems Applicability of Adjustment Factors for Structural Glued Laminated Timber Average Specific Gravity and Weight Factor Applicability of Adjustment Factors for Round Timber Poles and Piles Applicability of Adjustment Factors for Prefabricated Wood I-Joists Applicability of Adjustment Factors for Structural Composite Lumber M9.1-1 Guide to Panel Use M9.2-1 M9.2-2 M9.2-3 Wood Structural Panel Bending Stiffness and Strength Capacities Wood Structural Panel Axial Stiffness, Tension, and Compression Capacities Wood Structural Panel Shear-in-the-Plane Capacities M15: SPECIAL LOADING CONDITIONS...89 M15.1 Lateral Distribution of Concentrated Loads M15.2 Spaced Columns M15.3 Built-Up Columns M15.4 Wood Columns with Side Loads and Eccentricity M16: FIRE DESIGN M16.1 General M16.2 Design Procedures for Exposed Wood Members M16.3 Wood Connections M9.2-4 M9.3-1 Wood Structural Panel Rigidity and Shear Through-the-Thickness Capacities Applicability of Adjustment Factors for Wood Structural Panels M9.4-1 Panel Edge Support M9.4-2 Minimum Nailing for Wood Structural Panel Applications M Allowable Design Properties for the Parallel Layers of PRG 320 CLT (for use in the U.S.) M Allowable Bending Capacities for CLT Grades (for use in the U.S.) M Applicability of Adjustment Factors for Cross-Laminated Timber M Applicability of Adjustment Factors for Mechanical Connections M Applicability of Adjustment Factors for Dowel-Type Fasteners M Applicability of Adjustment Factors for Split Ring and Shear Plate Connectors M Applicability of Adjustment Factors for Timber Rivets M Heavy Timber Size Equalivalencies M Minimum Sizes to Qualify as Heavy Timber Construction M Privacy Afforded According to STC Rating... 99

9 MANUAL FOR ENGINEERED WOOD CONSTRUCTION vii LIST OF FIGURES M5.1-1 M5.2-1 Unbalanced and Balanced Layup Combinations Structural Glued Laminated Timber Axes Orientations M7.4-1 Design Span Determination M7.4-2 Load Case Evaluations M7.4-3 End Bearing Web Stiffeners (Bearing Block) M7.4-4 Web Stiffener Bearing Interface M7.4-5 Beveled End Cut M7.4-6 Sloped Bearing Conditions (Low End) M7.4-7 Sloped Bearing Conditions (High End) M7.4-8 Lateral Support Requirements for Joists in Hangers M7.4-9 Top Flange Hanger Support M Connection Requirements for Face Nail Hangers M Details for Vertical Load Transfer M9.2-1 Structural Panel with Strength Direction Across Supports M9.2-2 Example of Structural Panel in Bending M9.2-3 Structural Panel with Axial Compression Load in the Plane of the Panel M9.2-4 M9.2-5 Shear-in-the-Plane for Wood Structural Panels Through-the-Thickness Shear for Wood Structural Panels M Example of CLT Panel in Bending M CLT Panel in Bending with Axial Compression Load in the Plane of the Panel M Shear-in-the-Plane for CLT Panels M Through-the-Thickness Shear for CLT Panels M Cross Sections of Possible One-Hour Area Separations M Beam to Column Connection - Connection Not Exposed to Fire M Beam to Column Connection - Connection Exposed to Fire Where Appearance is a Factor M Beam to Column Connection - Connection Exposed to Fire Where Appearance is Not a Factor M Column Connections Covered M Beam to Girder - Concealed Connection

10 viii MANUAL FOR ENGINEERED WOOD CONSTRUCTION

11 MANUAL FOR ENGINEERED WOOD CONSTRUCTION 1 M1: GENERAL REQUIREMENTS FOR STRUCTURAL DESIGN 1 M1.1 Products Covered in This Manual 2 M1.2 General Requirements 2 M1.2.1 Bracing 2 M1.3 Design Procedures 2

12 2 M1: GENERAL REQUIREMENTS FOR STRUCTURAL DESIGN M1.1 Products Covered in This Manual This Manual was developed with the intention of covering all structural applications of wood-based products and their connections that meet the requirements of the referenced standards. The Manual is a dual format document incorporating design provisions for both allowable stress design (ASD) and load and resistance factor design (LRFD). Design information is available for the following list of products. Each product chapter contains information for use with this Manual and the National Design Specification (NDS ) for Wood Construction. Chapters are organized to parallel the chapter format of the NDS. Sawn Lumber Chapter 4 Structural Glued Laminated Timber Chapter 5 Round Timber Poles and Piles Chapter 6 Prefabricated Wood I-Joists Chapter 7 Structural Composite Lumber Chapter 8 Wood Structural Panels Chapter 9 Cross-Laminated Timber Chapter 10 Mechanical Connections Chapter 11 Dowel-Type Fasteners Chapter 12 Split Ring and Shear Plate Connectors Chapter 13 Timber Rivets Chapter 14 An additional Standard, titled Special Design Provisions for Wind and Seismic (SDPWS), has been developed to cover materials, design, and construction of wood members, fasteners, and assemblies to resist wind and seismic forces. M1.2 General Requirements This Manual is organized for use with the Wood Design Package which includes the following documents: NDS and Commentary; NDS Supplement: Design Values for Wood Construction, Special Design Provisions for Wind and Seismic (SDPWS) and Commentary, M1.2.1 Bracing Design considerations related to both temporary and permanent bracing differ among product types. Specific discussion of bracing is included in the product chapter. M1.3 Design Procedures The NDS is a dual format specification incorporating design provisions for ASD and LRFD. Behavioral equations, such as those for member and connection design, are the same for both ASD and LRFD. Adjustment factor tables include applicable factors for determining an adjusted ASD design value or an adjusted LRFD design value. NDS Appendix N (Mandatory) Load and Resistance Factor Design (LRFD) and product chapters outline requirements that are unique to LRFD and adjustment factors for LRFD. The basic design equations for ASD or LRFD require that the specified product adjusted design value meet or exceed the actual (applied) stress or other effect imposed by the specified loads. Load combination equations for use with ASD and LRFD are given in the model building codes.

13 MANUAL FOR ENGINEERED WOOD CONSTRUCTION 3 M2: DESIGN VALUES FOR STRUCTURAL MEMBERS 2 M2.1 General Information 4 M2.2 Reference Design Values 4 M2.3 Adjustment of Design Values 4

14 4 M2: DESIGN VALUES FOR STRUCTURAL MEMBERS M2.1 General Information Structural wood products are provided to serve a wide range of end uses. Some products are marketed through commodity channels where the products meet specific standards and the selection of the appropriate product is the responsibility of the user. Other products are custom manufactured to meet the specific needs of a given project. Products in this category are metal plate connected wood trusses and custom structural glued laminated timbers. Design of the individual members is based on criteria specified by the architect or engineer of record on the project. Manufacture of these products is performed in accordance with the product s manufacturing standards. Engineering of these products normally only extends to the design of the products themselves. Construction-related issues, such as load path analysis and erection bracing, remain the responsibility of the professional of record for the project. M2.2 Reference Design Values Reference design value designates the allowable stress design value based on normal load duration. To avoid confusion, the descriptor reference is used and serves as a reminder that design value adjustment factors are applicable for design values in accordance with referenced conditions specified in the NDS such as normal load duration. Reference design values for sawn lumber, structural glued laminated timber, and round timber poles and piles are contained in the NDS Supplement: Design Values for Wood Construction. Reference design values for doweltype fasteners, split ring and shear plate connectors, and timber rivets are contained in the NDS. Reference design values for all other products are typically contained in the manufacturer s code evaluation report. M2.3 Adjustment of Reference Design Values Adjusted design value designates reference design values which have been multiplied by adjustment factors. Basic requirements for design use terminology applicable to both ASD and LRFD. In equation format, this takes the standard form f b F b which is applicable to either ASD or LRFD. Reference design values (F b, F t, F v, F c, F c, E, E min ) are multiplied by adjustment factors to determine adjusted design values (F b, F t, F v, F c, F c, E, E min ). Reference conditions have been defined such that a majority of wood products used in interior or in protected environments will require no adjustment for moisture, temperature, or treatment effects. Moisture content (MC) reference conditions are 19% or less for sawn lumber products. The equivalent limit for glued products (structural glued laminated timber, structural composite lumber, prefabricated wood I-joists, wood structural panels, and cross-laminated timber) is defined as 16% MC or less. Temperature reference conditions include sustained temperatures up to 100ºF. Note that it has been traditionally assumed that these reference conditions also include common building applications in desert locations where daytime temperatures will often exceed 100ºF. Examples of applications that may exceed the reference temperature range include food processing or other industrial buildings. Tabulated design values and capacities are for untreated members. Tabulated design values and capacities also apply to wood products pressure treated by an approved process and preservative except as specified for load duration factors. An unincised reference condition is assumed. For members that are incised to increase penetration of preservative chemicals, use the incising adjustment factors given in the product chapter. The effects of fire retardant chemical treatment on strength shall be accounted for in the design. Reference design values, including connection design values, for lumber and structural glued laminated timber pressuretreated with fire retardant chemicals shall be obtained from the company providing the treatment and redrying service. The impact load duration factor shall not apply to structural members pressure-treated with fire retardant chemicals.

15 MANUAL FOR ENGINEERED WOOD CONSTRUCTION 5 M3: DESIGN PROVISIONS AND EQUATIONS 3 M3.1 General 6 M3.2 Bending Members - General 6 M3.3 Bending Members - Flexure 6 M3.4 Bending Members - Shear 6 M3.5 Bending Members - Deflection 7 M3.6 Compression Members 7 M3.7 Solid Columns 8 M3.8 Tension Members 8 M3.8.1 Tension Parallel to Grain 8 M3.8.2 Tension Perpendicular to Grain 8 M3.9 Combined Bending and Axial Loading 8 M3.10 Design for Bearing 9

16 6 M3: DESIGN PROVISIONS AND EQUATIONS M3.1 General This Chapter covers design of members for bending, compression, tension, combined bending and axial loads, and bearing. M3.2 Bending Members - General This section covers design of members stressed primarily in flexure (bending). Examples of such members include primary framing members (beams) and secondary framing members (purlins, joists). Products commonly used in these applications include glulam, solid sawn lumber, structural composite lumber, and prefabricated I joists. Bending members are designed so that no design capacity is exceeded under applied loads. Strength criteria for bending members include bending moment, shear, local buckling, lateral torsional buckling, and bearing. See specific product chapters for moment and shear capacities (joist and beam selection tables) and reference bending and shear design values. M3.3 Bending Members - Flexure The basic equation for moment design of bending members is: M M (M3.3-1) where: M = adjusted moment capacity M = bending moment The equation for calculation of adjusted moment capacity is: M = F b S (M3.3-2) where: S = section modulus, in. 3 F b = adjusted bending design value, psi. See product chapters for applicable adjustment factors. M3.4 Bending Members - Shear The basic equation for shear design of bending members is: V V (M3.4-1) where: V = adjusted shear capacity parallel to grain, lbs V = shear force, lbs The equation for calculation of shear capacity is: V = F v Ib/Q (M3.4-2) which, for rectangular unnotched bending members, reduces to: V = 2/3 (F v ) A (M3.4-3) where: I = moment of inertia, in. 4 A = area, in. 2 F v = adjusted shear design value, psi. See product chapters for applicable adjustment factors.

17 MANUAL FOR ENGINEERED WOOD CONSTRUCTION 7 M3.5 Bending Members - Deflection Users should note that design of bending members is often controlled by serviceability limitations rather than strength. Serviceability considerations, such as deflection and vibration, are often designated by the authority having jurisdiction. For a simple span uniformly loaded rectangular member, the equation used for calculating mid-span deflection is: = 5 4 w (M3.5-1) 384EI where: = deflection, in. w = uniform load, lb/in. M3.6 Compression Members This section covers design of members stressed primarily in compression parallel to grain. Examples of such members include columns, truss members, and diaphragm chords. Information in this section is limited to the case in which loads are applied concentrically to the member. Provisions of NDS 3.9 or NDS Chapter 15 should be used if loads are eccentric or if the compressive forces are applied in addition to bending forces. The NDS differentiates between solid, built-up, and spaced columns. In this context built-up columns are assembled from multiple pieces of similar members connected in accordance with NDS A spaced column must comply with provisions of NDS Note that this definition includes main column elements, spacer blocks with their connectors, and end blocks with shear plate or split ring connectors. Compression Parallel to Grain The basic equation for design of compression members is: P P (M3.6-1) where: P = adjusted compression parallel to grain capacity, lbs P = compressive force, lbs = span, in. E I = stiffness of beam section, lb-in. 2 Values of modulus of elasticity, E, and moment of inertia, I, for lumber and structural glued laminated timber for use in the preceding equation can be found in the NDS Supplement. Engineered wood products such as I-joists and structural composite lumber will have EI values published in individual manufacturer s product literature or evaluation reports. Some manufacturers might publish true E which would require additional computations to account for shear deflection. See NDS Appendix F for information on shear deflection. See product chapters for more details about deflection calculations. The complete equation for calculation of adjusted compression capacity is: P = F c A (M3.6-2) where: A = area, in. 2 F c = adjusted compression parallel to grain design value, psi. See product chapters for applicable adjustment factors. Special Considerations Net Section Calculation As in design of tension members, compression members should be checked both on a gross section and a net section basis (see NDS 3.6.3). Bearing Capacity Checks Design for bearing is addressed in NDS Radial Compression in Curved Members Stresses induced in curved members under load include a component of stress in the direction of the radius of curvature. Radial compression is a specialized design consideration that is addressed in NDS M3: DESIGN PROVISIONS AND EQUATIONS

18 8 M3: DESIGN PROVISIONS AND EQUATIONS M3.7 Solid Columns Slenderness Considerations and Stability The user is cautioned that stability calculations are highly dependent upon boundary conditions assumed in the analysis. For example, the common assumption of a pinned-pinned column is only accurate or conservative if the member is restrained against sidesway. If sidesway is possible and a pinned-free condition exists, the value of K e in NDS doubles (see NDS Appendix Table G1 for recommended buckling length coefficients, K e ) and the computed adjusted compression parallel to grain capacity decreases. M3.8 Tension Members This section covers design of members stressed primarily in tension parallel to grain. Examples of such members include shear wall end posts, truss members, and diaphragm chords. The designer is advised that use of wood members in applications that induce tension perpendicular to grain stresses should be avoided. M3.8.1 Tension Parallel to Grain The basic equation for design of tension members is: T T (M3.8-1) where: T = adjusted tension parallel to grain capacity, lbs T = tensile force, lbs The equation for calculation of adjusted tension capacity is: T = F t A (M3.8-2) where: A = area, in. 2 F t = adjusted tension design value, psi. See product chapters for applicable adjustment factors. Net Section Calculation Design of tension members is often controlled by the ability to provide connections to develop tensile forces within the member. In the area of connections, one must design not only the connection itself (described in detail in Chapter M11) but also the transfer of force across the net section of the member. One method for determining these stresses is provided in NDS Appendix E. M3.8.2 Tension Perpendicular to Grain Radial Stress in Curved Members Stresses induced in curved members under load include a component of stress in the direction of the radius of curvature. This stress is traditionally called radial tension. Radial stress design is a specialized consideration that is covered in NDS M3.9 Combined Bending and Axial Loading This section covers design of members stressed under combined bending and axial loads. The applicable strength criteria for these members is explicit in the NDS equations limiting the sum of various stress ratios to less than or equal to unity. Bending and Axial Tension For designs in which the axial load is in tension rather than compression, the designer should use NDS Equations and

19 MANUAL FOR ENGINEERED WOOD CONSTRUCTION 9 Bending and Axial Compression The equation for design of members under bending plus compression loads is given below in terms of load and moment ratios: 2 P M M P P M P M P M 2 E PE (M3.9-1) 1 M 2 E where: P = adjusted compression capacity determined per M3.6, lbs P = compressive force determined per M3.6, lbs M 1 = adjusted moment capacity (strong axis) determined per M3.3, in.-lbs M 1 = bending moment (strong axis) determined per M3.3, in.-lbs M 2 = adjusted moment capacity (weak axis) determined per M3.3, in.-lbs M 2 = bending moment (weak axis) determined per M3.3, in.-lbs P E1 = F ce1 A = critical column buckling capacity (strong axis) determined per NDS 3.9.2, lbs P E2 = F ce2 A = critical column buckling capacity (weak axis) determined per NDS 3.9.2, lbs M E = F be S = critical beam buckling capacity determined per NDS 3.9.2, in.-lbs Members must be designed by multiplying all applicable adjustment factors by the reference design values for the product. See M3.3 and M3.6 for discussion of applicable adjustment factors for bending or compression, respectively. Equation in the NDS is used to check the intermediate calculation for members subjected to flatwise bending in combination with axial compression, with or without edgewise bending. When a flatwise bending load is checked with the third term of the stress interaction equation (NDS Equation 3.9-3), the axial and edgewise bending interaction in the denominator can become a negative value. The occurrence of the negative value indicates an overstress. However, use of this negative term in the stress interaction equation (NDS Equation 3.9-3) overlooks the overstress in flatwise bending and incorrectly reduces the overall interaction. Design Techniques A key to understanding design of members under combined bending and axial loads is that components of the design equation are simple ratios of compressive force (or moment) to compression capacity (or moment capacity). Note that the compression term in this equation is squared. This is the result of empirical test data. Moderate compressive forces do not have as large an impact on capacity (under combined loads) as previously thought. It is believed that this is the result of compressive reinforcing of what would otherwise be a tensile failure mode in bending. 3 M3: DESIGN PROVISIONS AND EQUATIONS M3.10 Design for Bearing Columns often transfer large forces within a structural system. While satisfaction of column strength criteria is usually the primary concern, the designer should also check force transfer at the column bearing. For cases in which the column is bearing on another wood member, especially if bearing is perpendicular to grain, this calculation will often control the design. The basic equation for bearing design is: R R (M3.10-1) where: R = adjusted compression perpendicular to grain capacity, lbs R = compressive force or reaction, lbs The equation for calculation of adjusted compression perpendicular to grain capacity is: R = F c A (M3.10-2) where: A = area, in. 2 F c = adjusted compression perpendicular to grain design value, psi. See product chapters for applicable adjustment factors.

20 10 M3: DESIGN PROVISIONS AND EQUATIONS

21 MANUAL FOR ENGINEERED WOOD CONSTRUCTION 11 M4: SAWN LUMBER 4 M4.1 General 12 M4.2 Reference Design Values 12 M4.3 Adjustment of Reference Design Values 13 M4.4 Special Design Considerations 14

22 12 M4: SAWN LUMBER M4.1 General Product Information Structural lumber products are well-known throughout the construction industry. The economic advantages of lumber often dictate its choice as a preferred building material. Lumber is available in a wide range of species, grades, sizes, and moisture contents. Structural lumber products are typically specified by either the stress level required or by the species, grade, and size required. This Chapter provides information for designing structural lumber products in accordance with the NDS. Common Uses Structural lumber and timbers have been a primary construction material throughout the world for many centuries. They are the most widely used framing material for housing in North America. In addition to use in housing, structural lumber finds broad use in commercial and industrial construction. Its high strength, universal availability, and cost saving attributes make it a viable option in most low- and mid-rise construction projects. Structural lumber is used as beams, columns, headers, joists, rafters, studs, and plates in conventional construction. In addition to its use in lumber form, structural lumber is used to manufacture structural glued laminated beams, trusses, wood I-joists, and cross-laminated timber. Availability Structural lumber is a widely available construction material. However, to efficiently specify structural lumber for individual construction projects, the specifier should be aware of the species, grades, and sizes available locally. The best source of this information is your local lumber supplier. M4.2 Reference Design Values General The NDS Supplement provides reference design values for design of sawn lumber members. These design values are used when manual calculation of member capacity is required and must be used in conjunction with the adjustment factors specified in NDS 4.3. Reference Design Values Reference design values are provided in the NDS Supplement as follows: NDS Supplement Table Number 4A and 4B 4C 4D 4E 4F Visually graded dimension lumber Mechanically graded dimension lumber Visually graded timbers Visually graded decking Non-North American visually graded dimension lumber

23 MANUAL FOR ENGINEERED WOOD CONSTRUCTION 13 M4.3 Adjustment of Reference Design Values To generate member design capacities, reference design values for sawn lumber are multiplied by adjustment factors and section properties per Chapter M3. Applicable adjustment factors for sawn lumber are defined in NDS 4.3. Table M4.3-1 shows the applicability of adjustment factors for sawn lumber in a slightly different format for the designer. Table M4.3-1 Applicability of Adjustment Factors for Sawn Lumber 4 Allowable Stress Design Load and Resistance Factor Design F b = F b C D C M C t C L C F C fu C i C r F b = F b C M C t C L C F C fu C i C r (2.54)(0.85) λ F t = F t C D C M C t C F C i F t = F t C M C t C F C i (2.70)(0.80) λ F v = F v C D C M C t C i F v = F v C M C t C i (2.88)(0.75) λ F c = F c C M C t C i C b F c = F c C M C t C i C b (1.67)(0.90) F c = F c C D C M C t C F C i C P F c = F c C M C t C F C i C P (2.40)(0.90) λ M4: SAWN LUMBER E = E C M C t C i E = E C M C t C i E min = E min C M C t C i C T E min = E min C M C t C i C T (1.76)(0.85) Bending Member Example For unincised, straight, laterally supported bending members stressed in edgewise bending in single member use and used in a normal building environment (meeting the reference conditions of NDS 2.3 and 4.3), the adjusted design values reduce to: For ASD: F b = F b C D C F F v = F v C D F c = F c C b E = E For LRFD: F b = F b C F (2.54)(0.85) λ F v = F v (2.88)(0.75) λ F c = F c C b (1.67)(0.90) E = E Axially Loaded Member Example For unincised axially loaded members used in a normal building environment (meeting the reference conditions of NDS 2.3 and 4.3) designed to resist tension or compression loads, the adjusted tension or compression design values reduce to: For ASD: F c = F c C D C F C P F t = F t C D C F E min = E min For LRFD: F c = F c C F C P (2.40)(0.90) λ F t = F t C F (2.70)(0.80) λ E min = E min (1.76)(0.85)

24 14 M4: SAWN LUMBER M4.4 Special Design Considerations General With proper detailing and protection, structural lumber can perform well in a variety of environments. One key to proper detailing is planning for the natural shrinkage and swelling of wood members as they are subjected to various drying and wetting cycles. While moisture changes have the largest impact on lumber dimensions, some designs must also check the effects of temperature on dimensions as well. Dimensional Changes Table M4.4-1 is extracted from more precise scientific and research reports on these topics. The coefficients are conservative (yielding more shrinkage and expansion than one might expect for most species). This level of information should be adequate for common structural applications. Equations are provided in this section for those designers who require more precise calculations. Design of wood members and assemblies for fire resistance is discussed in Chapter M16. Table M4.4-1 Approximate Moisture and Thermal Dimensional Changes Description Dimensional change due to moisture content change 1 Dimensional change due to temperature change 2 Radial or Tangential Direction 1% change in dimension per 4% change in MC in./in. per degree F 1. Corresponding longitudinal direction shrinkage/expansion is about 1% to 5% of that in radial and tangential directions. 2. Corresponding longitudinal direction coefficient is about 1/10 as large as radial and tangential. Equations for Computing Moisture and Thermal Shrinkage/Expansion Due to Moisture Changes For more precise computation of dimensional changes due to changes in moisture, the change in radial (R), tangential (T), and volumetric (V) dimensions due to changes in moisture content can be calculated as: X X MC e (M4.4-1) = ( ) o ME where: X 0 = initial dimension or volume and: X = dimension or volume change MC = moisture content change (%) e ME = coefficient of moisture expansion: linear (in./in./%mc) or volumetric (in. 3 /in. 3 /%MC) MC = M M o (M4.4-2) where: M o = initial moisture content % (M o FSP) M = new moisture content % (M FSP) FSP = fiber saturation point Values for e ME and FSP are shown in Table M Due to Temperature Changes For more precise calculation of dimensional changes due to changes in temperature, the shrinkage/expansion of solid wood including lumber and timbers can be calculated as: X X T e (M4.4-3) = ( ) o TE where: X 0 = reference dimension at T 0 and: where: X = computed dimension at T T 0 = reference temperature ( F) T = temperature at which the new dimension is calculated ( F) e TE = coefficient of thermal expansion (in./in./ F) T = T T o (M4.4-4) 60 F T o 130 F The coefficient of thermal expansion of ovendry wood parallel to grain ranges from about to per F.

25 MANUAL FOR ENGINEERED WOOD CONSTRUCTION 15 The linear expansion coefficients across the grain (radial and tangential) are proportional to wood density. These coefficients are about five to ten times greater than the parallel-to-the-grain coefficients and are given as: Radial: e TE G in./in. / F (M4.4-5) Tangential: Table M4.4-2 Species ( ) e = ( TE G ) in./in. / F (M4.4-6) where: ( ) G = tabulated specific gravity for the species. Coefficient of Moisture Expansion, e ME, and Fiber Saturation Point, FSP, for Solid Woods Radial (in./in./%) Tangential (in./in./%) e ME Volumetric (in. 3 /in. 3 /%) Alaska Cedar Douglas Fir-Larch Englemann Spruce Redwood Red Oak Southern Pine Western Hemlock Yellow Poplar FSP (%) 4 M4: SAWN LUMBER Table M4.4-3 provides the numerical values for e TE for the most commonly used commercial species or species groups. Wood that contains moisture reacts to varying temperature differently than does dry wood. When moist wood is heated, it tends to expand because of normal thermal expansion and to shrink because of loss in moisture content. Unless the wood is very dry initially (perhaps 3% or 4% MC or less), the shrinkage due to moisture loss on heating will be greater than the thermal expansion, so the net dimensional change on heating will be negative. Wood at intermediate moisture levels (about 8% to 20%) will expand when first heated, then gradually shrink to a volume smaller than the initial volume, as the wood gradually loses water while in the heated condition. Even in the longitudinal (grain) direction, where dimensional change due to moisture change is very small, such changes will still predominate over corresponding dimensional changes due to thermal expansion unless the wood is very dry initially. For wood at usual moisture levels, net dimensional changes will generally be negative after prolonged heating. Calculation of actual changes in dimensions can be accomplished by determining the equilibrium moisture content of wood at the temperature value and relative humidity of interest. Then the relative dimensional changes due to temperature change alone and moisture content change alone are calculated. By combining these two changes the final dimension of lumber and timber can be established.

26 16 M4: SAWN LUMBER Table M4.4-3 Coefficient of Thermal Expansion, e TE, for Solid Woods e TE Species Radial (10-6 in./in./ F) Tangential (10-6 in./in./ F) California Redwood Douglas Fir-Larch Douglas Fir-South Eastern Spruce Hem-Fir Red Oak Southern Pine Spruce-Pine-Fir Yellow Poplar Also applies when species name includes the designation North. Durability Designing for durability is a key part of the architectural and engineering design of the building. Many design conditions can be detailed to minimize the potential for decay; for other problem conditions, preservative-treated wood or naturally durable species should be specified. This section does not cover the topic of designing for durability in detail. There are many excellent texts on the topic, including AWC s Design of Wood Structures for Permanence, WCD No. 6. Designers are advised to use this type of information to assist in designing for difficult design areas, such as: structures in moist or humid conditions where wood comes in contact with concrete or masonry where wood members are supported in steel hangers or connectors in which condensation could collect anywhere that wood is directly or indirectly exposed to the elements where wood, if it should ever become wet, could not naturally dry out. This list is not intended to be all-inclusive it is merely an attempt to alert designers to special conditions that may cause problems when durability is not considered in the design.

27 MANUAL FOR ENGINEERED WOOD CONSTRUCTION 17 M5: STRUCTURAL GLUED LAMINATED TIMBER 5 M5.1 General 18 M5.2 Reference Design Values 20 M5.3 Adjustment of Reference Design Values 21 M5.4 Special Design Considerations 22

28 18 M5: STRUCTURAL GLUED LAMINATED TIMBER M5.1 General Products Description Structural glued laminated timber (glulam) is a structural member glued up from suitably selected and prepared pieces of wood either in a straight or curved form with the grain of all of the pieces parallel to the longitudinal axis of the member. The reference design values given in the NDS Supplement are applicable only to structural glued laminated timber members produced in accordance with American National Standard for Wood Products Structural Glued Laminated Timber, ANSI A Structural glued laminated timber members are produced in laminating plants by gluing together dry lumber, normally of 2-inch or 1-inch nominal thickness, under controlled temperature and pressure conditions. Members with a wide variety of sizes, profiles, and lengths can be produced having superior characteristics of strength, serviceability, and appearance. Structural glued laminated timber beams are manufactured with the strongest laminations on the bottom and top of the beam, where the greatest tension and compression stresses occur in bending. This allows a more efficient use of the lumber resource by placing higher grade lumber in zones that have higher stresses and lumber with less structural quality in lower stressed zones. Structural glued laminated timber members are manufactured from several softwood species, primarily Douglas fir-larch, southern pine, hem-fir, spruce-pine-fir, eastern spruce, and Alaska cedar. Other species including redwood and various hardwoods are occasionally used. Standard structural glued laminated timber sizes are given in the NDS Supplement. Any length, up to the maximum length permitted by transportation and handling restrictions, is available. A structural glued laminated timber member can be manufactured using a single grade or multiple grades of lumber, depending on intended use. In addition, a mixedspecies structural glued laminated timber member is also possible. When the member is intended to be primarily loaded either axially or in bending with the loads acting parallel to the wide faces of the laminations, a single grade combination is recommended. On the other hand, a multiple grade combination provides better cost-effectiveness when the member is primarily loaded in bending due to loads applied perpendicular to the wide faces of the laminations. On a multiple grade combination, a structural glued laminated timber member can be produced as either a balanced or unbalanced combination, depending on the geometrical arrangement of the laminations about the mid-depth of the member. As shown in Figure M5.1-1, a balanced combination is symmetrical about the mid-depth, so it has the same reference bending design values for both positive and negative bending. Unbalanced combinations are asymmetrical about the mid-depth, so they have lower reference design values for negative bending than for positive bending. The top face of an unbalanced member is required to be marked TOP by the manufacturer. The balanced combinations are intended for use in continuous or cantilevered applications to provide equal capacity in both positive and negative bending. Whereas unbalanced combinations are primarily for use in simple span applications, they can also be used for short cantilever applications (cantilever less than 20% of the back span) or for continuous span applications when the design is controlled by shear or deflection. Figure M5.1-1 B C B A Unbalanced Unbalanced and Balanced Layup Combinations A B C B A Balanced Structural glued laminated timber members can be used as primary or secondary load-carrying components in structures. Table M5.1-1 lists economical spans for selected timber framing systems using structural glued laminated timber members in buildings. Other common uses of structural glued laminated timber members are for utility structures, pedestrian bridges, highway bridges, railroad bridges, marine structures, noise barriers, and towers. Table M5.1-1 may be used for preliminary design purposes to determine the economical span ranges for the selected framing systems. However, all systems require a more extensive analysis for final design.

29 MANUAL FOR ENGINEERED WOOD CONSTRUCTION 19 Table M5.1-1 Economical Spans for Structural Glued Laminated Timber Framing Systems Type of Framing System Economical Spans (ft) ROOF Simple Span Beams Straight or slightly cambered 10 to 100 Tapered, double tapered-pitched, or 25 to 105 curved Cantilevered Beams (Main span) up to 90 Continuous Beams (Interior spans) 10 to 50 Girders 40 to 100 Three-Hinged Arches Gothic 40 to 100 Tudor 40 to 140 A-Frame 20 to 100 Three-centered, Parabolic, or Radial 40 to 250 Two-Hinged Arches Radial or Parabolic 50 to 200 Trusses (Four or more ply chords) Flat or parallel chord 50 to 150 Triangular or pitched 50 to 150 Bowstring (Continuous chord) 50 to 200 Trusses (Two or three ply chords) Flat or parallel chord 20 to 75 Triangular or pitched 20 to 75 Tied arches 50 to 200 Dome structures 200 to 500+ FLOOR Simple Span Beams 10 to 40 Continuous Beams (Individual spans) 10 to 40 HEADERS Windows and Doors < 10 Garage Doors 9 to 18 Appearance Classifications Structural glued laminated timber members are typically produced in four appearance classifications: Premium, Architectural, Industrial, and Framing. Premium and Architectural beams are higher in appearance qualities and are surfaced for a smooth finish ready for staining or painting. Industrial classification beams are normally used in concealed applications or in construction where appearance is not important. Framing classification beams are typically used for headers and other concealed applications in residential construction. Design values for structural glued laminated timber members are independent of the appearance classifications. For more information and detailed descriptions of these appearance classifications and their typical uses, refer to APA EWS Technical Note Y110 or AITC Standard 110. Availability Structural glued laminated timber members are available in both custom and stock sizes. Custom beams are manufactured to the specifications of a specific project, while stock beams are made in common dimensions, shipped to distribution yards, and cut to length when the beam is ordered. Stock beams are available in virtually every major metropolitan area. Although structural glued laminated timber members can be custom fabricated to provide a nearly infinite variety of forms and sizes, the best economy is generally realized by using standard-size members as noted in the NDS Supplement. When in doubt, the designer is advised to check with the structural glued laminated timber supplier or manufacturer concerning the availability of a specific size prior to specification. 5 M5: STRUCTURAL GLUED LAMINATED TIMBER

30 20 M5: STRUCTURAL GLUED LAMINATED TIMBER M5.2 Reference Design Values Reference design values of structural glued laminated timber are affected by the layup of members composed of various grades of lumber, as well as the orientation of the laminations relative to the applied loads. As a result, different design values are assigned for structural glued laminated timber used primarily in bending (NDS Supplement Table 5A) and primarily in axial loading (NDS Supplement Table 5B). The reference design values are used in conjunction with the dimensions provided in Table 1C (western species) and Table 1D (southern pine) of the NDS Supplement, but are applicable to any size of structural glued laminated timber when the appropriate modification factors discussed in M5.3 are applied. Reference design values are given in NDS Supplement Table 5A for bending about the X-X axis (see Figure M5.2 1). Although permitted, axial loading or bending about the Y-Y axis (also see Figure M5.2-1) is not efficient in using the structural glued laminated timber combinations given in NDS Supplement Table 5A. In such cases, the designer should select structural glued laminated timber from NDS Supplement Table 5B. Similarly, structural glued laminated timber combinations in NDS Supplement Table 5B are inefficiently utilized if the primary use is bending about the X-X axis. The reference design values given in NDS Supplement Tables 5A and 5B are based on use under normal duration of load (10 years) and dry conditions (less than 16% moisture content). When used under other conditions, see NDS Chapter 5 for adjustment factors. The reference bending design values are based on members loaded as simple beams. When structural glued laminated timber is used in continuous or cantilevered beams, the reference bending design values given in NDS Supplement Table 5A for top of beam stressed in tension should be used for the design of stress reversal. Figure M5.2-1 X Y Y X-X Axis Loading Structural Glued Laminated Timber Axes Orientations X Y X X Y-Y Axis Loading Y

31 MANUAL FOR ENGINEERED WOOD CONSTRUCTION 21 M5.3 Adjustment of Reference Design Values The adjustment factors provided in the NDS are for non-reference end-use conditions and material modification effects. These factors are used to modify the reference design values when one or more of the specific end uses or material modification conditions are beyond the limits of the reference conditions given in the NDS. Adjustment factors unique to structural glued laminated timber include the volume factor, C V, the curvature factor, C c,stress interaction factor, C I, and the shear reduction factor, C vr. All are defined in Chapter 5 of the NDS. To generate member design capacities, reference design values for structural glued laminated timber are multiplied by adjustment factors and section properties per Chapter M3. Applicable adjustment factors for structural glued laminated timber are defined in NDS 5.3. Table M5.3-1 shows the applicability of adjustment factors for structural glued laminated timber in a slightly different format for the designer. Table M5.3-1 Applicability of Adjustment Factors for Structural Glued Laminated Timber 1 5 Allowable Stress Design Load and Resistance Factor Design F b = F b C D C M C t C L C V C fu C c C I F b = F b C M C t C L C V C fu C c C I (2.54)(0.85) λ F t = F t C D C M C t F t = F t C M C t (2.70)(0.80) λ F v = F v C D C M C t C vr F v = F v C M C t C vr (2.88)(0.75) F rt ' = F rt C D C M C t F rt ' = F rt C M C t (2.88)(0.75) λ F c = F c C D C M C t C P F c = F c C M C t C P (2.40)(0.90) λ F c = F c C M C t C b F c = F c C M C t C b (1.67)(0.90) E = E C M C t E = E C M C t E min = E min C M C t E min = E min C M C t (1.76)(0.85) 1. The beam stability factor, C L, shall not apply simultaneously with the volume factor, C V, for structural glued laminated timber bending members (see NDS 5.3.6). Therefore, the lesser of these adjustment factors shall apply. Bending Member Example For straight, prismatic, untapered, laterally supported bending members loaded perpendicular to the wide face of the laminations and used in a normal building environment (meeting the reference conditions of NDS 2.3 and 5.3), the adjusted design values reduce to: Axially Loaded Member Example For axially loaded members used in a normal building environment (meeting the reference conditions of NDS 2.3 and 5.3) designed to resist tension or compression loads, the adjusted tension or compression design values reduce to: M5: STRUCTURAL GLUED LAMINATED TIMBER For ASD: F b = F b C D C V F v = F v C D F c = F c C b E = E For LRFD: F b = F b C V (2.54)(0.85) λ F v = F v (2.88)(0.75) λ F c = F c C b (2.40)(0.90) E = E For ASD: F c = F c C D C P F t = F t C D E min = E min For LRFD: F c = F c C P (2.40)(0.90) λ F t = F t (2.70)(0.80) λ E min = E min (1.76)(0.85)

32 22 M5: STRUCTURAL GLUED LAMINATED TIMBER M5.4 Special Design Considerations General This section contains information concerning physical properties of structural glued laminated timber members including specific gravity and response to moisture or temperature. In addition to designing to accommodate dimensional changes and detailing for durability, another significant design consideration is that of fire performance, which is discussed in Chapter M16. Note that the information contained in this section addresses design considerations separate from those described in NDS 5.4. Specific Gravity Table M5.4-1 provides specific gravity values for some of the most common wood species used for structural glued laminated timber. These values are used in determining various physical and connection properties. Further, weight factors are provided at four moisture contents. When the cross-sectional area (in. 2 ) is multiplied by the appropriate weight factor, it provides the weight of the structural glued laminated timber member per linear foot of length. For other moisture contents, the tabulated weight factors can be interpolated or extrapolated. Structural glued laminated timber members often are manufactured using different species at different portions of the cross section. In this case the weight of the structural glued laminated timber may be computed by the sum of the products of the cross-sectional area and the weight factor for each species. Dimensional Changes See M4.4 for information on calculating dimensional changes due to moisture or temperature. Durability See M4.4 for information on detailing for durability. Table M5.4-1 Average Specific Gravity and Weight Factor Weight Factor 2 Species Combination Specific Gravity 1 12% 15% 19% 25% California Redwood (close grain) Douglas Fir-Larch Douglas Fir (South) Eastern Spruce Hem-Fir Red Maple Red Oak Southern Pine Spruce-Pine-Fir (North) Yellow Poplar Specific gravity is based on weight and volume when ovendry. 2. Weight factor shall be multiplied by net cross-sectional area in in. 2 to obtain weight in pounds per lineal foot.

33 MANUAL FOR ENGINEERED WOOD CONSTRUCTION 23 M6: ROUND TIMBER POLES AND PILES M6.1 General 24 M6.2 Reference Design Values 24 M6.3 Adjustment of Reference Design Values 25 M6.4 Special Design Considerations 26 6

34 24 M6: ROUND TIMBER POLES AND PILES M6.1 General Product Information Timber poles and piles offer many advantages relative to competing materials. As with other wood products, timber poles and piles offer the unique advantage of being the only major construction material that is a renewable resource. Common Uses Timber poles are used extensively in post-frame construction and are also used architecturally. This Chapter is not for use with poles used in the support of utility lines. Timber piles are generally used as part of foundation systems. Availability Timber poles are supplied to the utility industry in a variety of grades and species. Because these poles are graded according to ANSI 05.1, Specifications and Dimensions for Wood Poles, they must be regraded according to ASTM D3200 if they are to be used with the NDS. Timber piles are typically available in three species: Pacific Coast Douglas-fir, southern pine, and red pine. However, local pile suppliers should be contacted because availability is dependent upon geographic location. M6.2 Reference Design Values General The tables in the NDS Supplement provide reference design values for timber pole and pile members. These reference design values are used when manual calculation of member strength is required and shall be used in conjunction with adjustment factors specified in NDS Chapter 6. These values, with the exception of F c, are applicable for all locations in the pole or pile. The F c values can be increased at other locations in accordance with NDS Reference design values for poles and piles are based on air dried conditioning. Kiln-drying, steam conditioning, or boultonizing prior to treatment will have the effect of reducing the reference design value per NDS Pole and Pile Reference Design Values Reference design values for piles and poles are provided in NDS Supplement Tables 6A and 6B, respectively.

35 MANUAL FOR ENGINEERED WOOD CONSTRUCTION 25 M6.3 Adjustment of Reference Design Values To generate member design capacities, reference design values are multiplied by adjustment factors and section properties. Adjustment factors unique to round timber poles and piles include the condition treatment factor, C ct, the critical section factor, C cs, and the load sharing factor, C ls. All are defined in Chapter 6 of the NDS. To generate member design capacities, reference design values for round timber poles and piles are multiplied by adjustment factors and section properties per Chapter M3. Applicable adjustment factors for round timber poles and piles are defined in NDS 6.3. Table M6.3-1 shows the applicability of adjustment factors for round timber poles and piles in a slightly different format for the designer. Table M6.3-1 Applicability of Adjustment Factors for Round Timber Poles and Piles Allowable Stress Design Load and Resistance Factor Design F c = F c C D C t C ct C P C cs C ls F c = F c C t C ct C P C cs C ls (2.40)(0.90) λ F b = F b C D C t C ct C F C ls F b = F b C t C ct C F C ls (2.54)(0.85) λ F v = F v C D C t C ct F v = F v C t C ct (2.88)(0.75) λ F c = F c C t C ct C b F c = F c C t C ct C b (1.67)(0.90) E = E C t E = E C t E min = E min C t E min = E min C t (1.76)(0.85) Axially Loaded Pole or Pile Example For single, axially loaded, air dried poles or piles, fully laterally supported in two orthogonal directions, used in a normal environment (meeting the reference conditions of NDS 2.3 and 6.3), designed to resist compression loads only, and less than 13.5" in diameter, the adjusted compression design values reduce to: 6 M6: ROUND TIMBER POLES AND PILES For ASD: F c = F c C D For LRFD: F c = F c (2.40)(0.90) λ

36 26 M6: ROUND TIMBER POLES AND PILES M6.4 Special Design Considerations With proper detailing and protection, timber poles and piles can perform well in a variety of environments. One key to proper detailing is planning for the natural shrinkage and swelling of wood products as they are subjected to various drying and wetting cycles. While moisture changes have the largest impact on product dimensions, some designs must also check the effects of temperature. See M4.4 for design information on dimensional changes due to moisture and temperature. Durability issues related to piles are generally both more critical and more easily accommodated. Since piles are in constant ground contact, they cannot be insulated from contact with moisture thus, the standard condition for piles is preservatively treated. The importance of proper treatment processing of piles cannot be overemphasized. See M4.4 for more information about durability. In addition to designing to accommodate dimensional changes and detailing for durability, another significant issue in the planning of wood structures is that of fire performance, which is discussed in Chapter M16.

37 MANUAL FOR ENGINEERED WOOD CONSTRUCTION 27 M7: PREFABRICATED WOOD I-JOISTS M7.1 General 28 M7.2 Reference Design Values 28 M7.3 Adjustment of Reference Design Values 30 M7.4 Special Design Considerations 31 7

38 28 M7: PREFABRICATED WOOD I-JOISTS M7.1 General Product Information Prefabricated wood I-joists are exceptionally stiff, lightweight, and capable of long spans. Holes may be easily cut in the web according to manufacturer s recommendations, allowing ducts and utilities to be run through the joist. I-joists are dimensionally stable and uniform in size, with no crown. This keeps floors quieter, reduces field modifications, and eliminates rejects in the field. I- joists may be field cut to proper length using conventional methods and tools. Manufacturing of I-joists utilizes the geometry of the cross section and high strength components to maximize the strength and stiffness of the wood fiber. Flanges are manufactured from solid sawn lumber or structural composite lumber, while webs typically consist of plywood or oriented strand board. The efficient utilization of raw materials, along with high-quality exterior adhesives and state of the art quality control procedures, result in an extremely consistent product that maximizes environmental benefits as well. Prefabricated wood I-joists are produced as proprietary products which are covered by code evaluation reports. Evaluation reports and product literature should be consulted for current design information. Common Uses Prefabricated wood I-joists are widely used as a framing material for housing in North America. I-joists are made in different grades and with various processes and can be utilized in various applications. Proper design is required to optimize performance and economics. In addition to use in housing, I-joists find increasing use in commercial and industrial construction. The high strength, stiffness, wide availability, and cost saving attributes make them a viable alternative in most low-rise construction projects. Prefabricated wood I-joists are typically used as floor and roof joists in conventional construction. In addition, I-joists are used as studs where long lengths and high strengths are required. Availability To efficiently specify I-joists for individual construction projects, consideration should be given to the size and the required strength of the I-joist. Sizes vary with each individual product. The best source of this information is your local lumber supplier, distribution center, or I-joist manufacturer. Proper design is facilitated through the use of manufacturer s literature and specification software available from I-joist manufacturers. M7.2 Reference Design Values Introduction to Design Values As stated in NDS 7.2, each wood I-joist manufacturer develops its own proprietary design values. The derivation of these values is reviewed by the applicable building code authority. Since materials, manufacturing processes, and product evaluations may differ between the various manufacturers, selected design values are only appropriate for the specific product and application. To generate the design capacity of a given product, the manufacturer of that product evaluates test data. The design capacity is then determined per ASTM D5055. The latest model building code agency evaluation reports are a reliable source for wood I-joist design values. These reports list accepted design values for shear, moment, stiffness, and reaction capacity based on minimum bearing. In addition, evaluation reports note the limitations on web holes, concentrated loads, and requirements for web stiffeners. Bearing/Reaction Design Tabulated design capacities reflect standard conditions and must be modified as discussed in NDS Chapter 7 to obtain adjusted design values. Bearing lengths at supports often control the design capacity of an I-joist. Typically minimum bearing lengths are used to establish design parameters. In some cases additional bearing is available and can be verified in an installation. Increased bearing length means that the joist can support additional loading, up to the value limited by the shear capacity of the web material and web joint. Both interior and exterior reactions must be evaluated. Use of web stiffeners may be required and typically increase the bearing capacity of the joist. Correct

39 MANUAL FOR ENGINEERED WOOD CONSTRUCTION 29 installation is required to obtain the specified capacities. Additional loading from walls above will load the joist in bearing, further limiting the capacity of the joist if proper end detailing is not followed. Additional information regarding design considerations for joist bearing can be found in M7.4. Adjusted design reactions (bearing capacities), R r, are determined in the same empirical fashion as is allowable shear. Deflection Design Wood I-joists, due to their optimized web materials, are susceptible to the effects of shear deflection. This component of deflection can account for as much as 15% to 30% of the total deflection. For this reason, both bending and shear deflection are considered in deflection design. A typical deflection calculation for simple span wood I-joists under uniform load is shown in Equation M Shear Design At end bearing locations, critical shear is the vertical shear at the ends of the design span. The practice of neglecting all uniform loads within a distance from the end support equal to the joist depth, commonly used for other wood materials, is not applicable to end supports for wood I-joists. At locations of continuity, such as interior supports of multi-span I-joists, the critical shear location for several wood I-joist types is located a distance equal to the depth of the joist from the centerline of bearing (uniform loads only). A cantilevered portion of a wood I-joist is generally not considered a location of continuity (unless the cantilever length exceeds the joist depth) and vertical shear at the cantilever bearing is the critical shear. Individual manufacturers, or the appropriate evaluation reports, should be consulted for reference to shear design at locations of continuity. Often, the adjusted shear design values, V r ', are based on other considerations such as bottom flange bearing length or the installation of web stiffeners or bearing blocks. Moment Design Reference moment design values, M r, of prefabricated wood I-joists are determined from empirical testing of a completely assembled joist or by engineering analysis supplemented by tension testing the flange component. If the flange contains end jointed material, the allowable tension value is the lesser of the joint capacity or the material capacity. Because flanges of a wood I-joist can be highly stressed, field notching of the flanges is not allowed. Similarly, excessive nailing or the use of improper nail sizes can cause flange splitting that will also reduce capacity. The manufacturer should be contacted when evaluating a damaged flange. Deflection = Bending Component + Shear Component 5w w = + 384EI k 4 2 (M7.2-1) where: w = uniform load in pounds per lineal inch = design span, in. E I = joist moment of inertia times flange modulus of elasticity k = shear deflection coefficient Individual manufacturers provide equations in a similar format. Values for use in the preceding equation can be found in the individual manufacturer s evaluation reports. For other load and span conditions, an approximate answer can be found by using conventional bending deflection equations adjusted as follows: Deflection = Bending Deflection EI 5 2 k Since wood I-joists can have long spans, the model building code maximum live load deflection criteria may not be appropriate for many floor applications. Many wood I-joist manufacturers recommend using stiffer criteria, such as L/480 for residential floor construction and L/600 for public access commercial applications such as office floors. The minimum code required criteria for storage floors and roof applications is normally adequate. 7 M7: PREFABRICATED WOOD I-JOISTS

40 30 M7: PREFABRICATED WOOD I-JOISTS M7.3 Adjustment of Reference Design Values General Member design capacity is the product of reference design values and adjustment factors. Reference design values for I-joists are discussed in M7.2. The design values listed in the evaluation reports are generally applicable to dry use conditions. Less typical conditions, such as high moisture, high temperatures, or pressure impregnated chemical treatments, typically result in strength and stiffness adjustments different from those used for sawn lumber. NDS 7.3 outlines adjustments to reference design values for I-joists; however, individual wood I-joist manufacturers should be consulted to verify appropriate adjustments. Table M7.3-1 shows the applicability of adjustment factors for prefabricated wood I-joists in a slightly different format for the designer. The user is cautioned that manufacturers may not permit the use of some applications and/or treatments. Unauthorized treatments can void a manufacturer s warranty and may result in structural deficiencies. Table M7.3-1 Applicability of Adjustment Factors for Prefabricated Wood I-Joists Allowable Stress Design M r = M r C D C M C t C L C r V r = V r C D C M C t R r = R r C D C M C t Load and Resistance Factor Design M r = M r C M C t C L C r K F (0.85) λ V r = V r C D C M C t K F (0.75) λ R r = R r C M C t K F (0.75) λ EI = EI C M C t EI = EI C M C t EI min = EI min C M C t EI min = EI min C M C t K F (0.85) K = K C M C t K = K C M C t Bending Member Example For fully laterally supported bending members loaded in strong axis bending and used in a normal building environment (meeting the reference conditions of NDS 2.3 and 7.3), the adjusted design values reduce to: For ASD: M r = M r C D V r = V r C D R r = R r C D E I = E I K = K For LRFD: M r = M r K F (0.85) λ V r = V r K F (0.75) λ R r = R r K F (0.75) λ EI = EI K = K Lateral Stability The design values contained in the evaluation reports for prefabricated wood I-joists assume the compression flange is supported throughout its length to prevent lateral displacement, and the ends at points of bearing have lateral support to prevent rotation (twisting). Lateral restraint is generally provided by diaphragm sheathing or bracing spaced at 16" on center or less (based on 1½" width joist flanges) nailed to the joist s compression flange. Applications without continuous lateral bracing will generally have reduced moment design capacities. The reduced capacity results from the increased potential for lateral buckling of the joist s compression flange. NDS provides guidance for design of an unbraced I-joist compression flange. Special Loads or Applications Wood I-joists are configured and optimized to act primarily as joists to resist bending loads supported at the bearing by the bottom flange. Applications that result in significant axial tension or compression loads, require web holes, special connections, or other unusual conditions should be evaluated only with the assistance of the individual wood I-joist manufacturers.

41 MANUAL FOR ENGINEERED WOOD CONSTRUCTION 31 M7.4 Special Design Considerations Introduction The wood I-joist is similar to conventional lumber in that it is based on the same raw materials, but differs in how the material is composed. For this reason, conventional lumber design practices are not always compatible with the unique configuration and wood fiber orientation of the wood I-joist. Designers using wood I-joists should develop solutions in accordance with the following guidelines. Durability issues cannot be overemphasized. See M4.4 for more information about durability. In addition to detailing for durability, another significant issue in the planning of wood structures is that of fire performance, which is discussed in Chapter M16. Design Span The design span used for determining critical shears and moments is defined as the clear span between the faces of support plus one-half the minimum required bearing on each end (see Figure M7.4-1). For most wood I-joists, the minimum required end bearing length varies from 1½" to 3½" (adding 2" to the clear span dimension is a good estimate for most applications). At locations of continuity over intermediate bearings, the design span is measured from the centerline of the intermediate support to the face of the bearing at the end support, plus one-half the minimum required bearing length. For interior spans of a continuous joist, the design span extends from centerline to centerline of the intermediate bearings. Figure M7.4-1 Design Span Determination 7 M7: PREFABRICATED WOOD I-JOISTS

42 32 M7: PREFABRICATED WOOD I-JOISTS Load Cases Most building codes require consideration of a critical distribution of loads. Due to the long length and continuous span capabilities of the wood I-joist, these code provisions have particular meaning. Considering a multiple span member, the following design load cases should be considered: All spans with total loads Alternate span loading Adjacent span loading Partial span loading (joists with holes) Concentrated load provisions (as occurs) A basic description of each of these load cases follows: All spans with total loads This load case involves placing all live and dead design loads on all spans simultaneously. Alternate span loading This load case places the L, L R, S, or R load portion of the design loads on every other span and can involve two loading patterns. The first pattern results in the removal of the live loads from all even numbered spans. The second pattern removes live loads from all odd numbered spans. For roof applications, some building codes require removal of only a portion of the live loads from odd or even numbered spans. The alternate span load case usually generates maximum end reactions, mid-span moments, and mid-span deflections. Illustrations of this type of loading are shown in Figure M Adjacent span loading This load case (see Figure M7.4-2) removes L, L R, S or R loads from all but two adjoining spans. All other spans, if they exist, are loaded with dead loads only. Depending on the number of spans involved, this load case can lead to a number of load patterns. All combinations of adjacent spans become separate loadings. This load case is used to develop maximum shears and reactions at internal bearing locations. Partial span loading This load case involves applying L, L R, S or R loads to less than the full length of a span (see Figure M7.4-2). For wood I-joists with web holes, this case is used to develop shear at hole locations. When this load case applies, uniform L, L R, S, R load is applied only from an adjacent bearing to the opposite edge of a rectangular hole (centerline of a circular hole). For each hole within a given span, there are two corresponding load cases. Live loads other than the uniform application load, located within the span containing the hole, are also applied simultaneously. This includes all special loads such as point or tapered loads. Concentrated load provisions Most building codes have a concentrated load (live load) provision in addition to standard application design loads. This load case considers this concentrated load to act in combination with the system dead loads on an otherwise unloaded floor or roof. Usually, this provision applies to non-residential construction. An example is the safe load applied over a 2½ square foot area for office floors. This load case helps insure the product being evaluated has the required shear and moment capacity throughout it s entire length and should be considered when analyzing the effect of web holes. A properly designed multiple span member requires numerous load case evaluations. Most wood I-joist manufacturers have developed computer programs, load and span tables, or both that take these various load cases into consideration.

43 MANUAL FOR ENGINEERED WOOD CONSTRUCTION 33 Figure M7.4-2 Load Case Evaluations 7 M7: PREFABRICATED WOOD I-JOISTS

44 34 M7: PREFABRICATED WOOD I-JOISTS Floor Performance Designing a floor system to meet the minimum requirements of a building code may not always provide acceptable performance to the end user. Although minimum criteria help assure a floor system can safely support the imposed loads, the system ultimately must perform to the satisfaction of the end user. Since expectancy levels may vary from one person to another, designing a floor system becomes a subjective issue requiring judgment as to the sensitivity of the intended occupant. Joist deflection is often used as the primary means for designing floor performance. Although deflection is a factor, there are other equally important variables that can influence the performance of a floor system. A glue-nailed floor system will generally have better deflection performance than a nailed only system. Selection of the decking material is also an important consideration. Deflection of the sheathing material between joists can be reduced by placing the joists at a closer on center spacing or increasing the sheathing thickness. Proper installation and job site storage are important considerations. All building materials, including wood I-joists, need to be kept dry and protected from exposure to the elements. Proper installation includes correct spacing of sheathing joints, care in fastening of the joists and sheathing, and providing adequate and level supports. All of these considerations are essential for proper system performance. Vibration may be a design consideration for floor systems that are stiff and where very little dead load (i.e., partition walls, ceilings, furniture, etc.) exists. Vibration can generally be damped with a ceiling system directly attached to the bottom flange of the wood I-joists. Effective bridging or continuous bottom flange nailers (i.e., 2x4 nailed flat-wise and perpendicular to the joist and tied off to the end walls) can also help minimize the potential for vibration in the absence of a direct applied ceiling. Limiting the span/depth ratio of the I-joist may also improve floor performance. Joist Bearing Bearing design for wood I-joists requires more than consideration of perpendicular to grain bearing values. Minimum required bearing lengths take into account a number of considerations. These include: cross grain bending and tensile forces in the flanges, web stiffener connection to the joist web, adhesive joint locations and strength, and perpendicular to grain bearing stresses. The model building code evaluation reports provide a source for bearing design information, usually in the form of minimum required bearing lengths. Usually, published bearing lengths are based on the maximum allowable shear capacity of the particular product and depth or allowable reactions are related to specific bearing lengths. Bearing lengths for wood I-joists are most often based on empirical test results rather than a calculated approach. Each specific manufacturer should be consulted for information when deviations from published criteria are desired. To better understand the variables involved in a wood I-joist bearing, it s convenient to visualize the member as a composition of pieces, each serving a specific task. For a typical simple span joist, the top flange is a compression member, the bottom flange is a tension member, and the web resists the vertical shear forces. Using this concept, shear forces accumulate in the web member at the bearing locations and must be transferred through the flanges to the support structure. This transfer involves two critical interfaces: between the flange and support member and between the web and flange materials. Starting with the support member, flange to support bearing involves perpendicular to grain stresses. The lowest design value for either the support member or flange material is usually used to develop the minimum required bearing area. The second interface to be checked is between the lower joist flange and the bottom edge of the joist web, assuming a bottom flange bearing condition. This connection, usually a routed groove in the flange and a matching shaped profile on the web, is a glued joint secured with a waterproof structural adhesive. The contact surfaces include the sides and bottom of the routed flange. In most cases, the adhesive line stresses at this joint control the bearing length design. The effective bearing length of the web into the flange is approximately the length of flange bearing onto the support plus an incremental length related to the thickness and stiffness of the flange material. Since most wood I-joists have web shear capacity in excess of the flange to web joint strength, connection reinforcement is sometimes utilized. The most common method of reinforcement is the addition of web stiffeners (also commonly referred to as bearing blocks). Web stiffeners are vertically oriented wood blocks positioned on both sides of the web. Web stiffeners should be cut so that a gap of at least 1/8" is between the stiffener and the flange to avoid a force fit. Stiffeners are positioned tight to the bottom flange at bearing locations and snug to the bottom of the top flange beneath heavy point loads within a span. Figure M7.4-3 provides an illustration of a typical end bearing assembly.

45 MANUAL FOR ENGINEERED WOOD CONSTRUCTION 35 Figure M7.4-3 End Bearing Web Stiffeners (Bearing Block) 7 Web Stiffeners When correctly fastened to the joist web, web stiffeners transfer some of the load from the web into the top of the bottom flange. This reduces the loads on the web to flange joint. A pair of web stiffeners (one on each side) is usually mechanically connected to the web with nails or staples loaded in double shear. For some of the higher capacity wood I-joists, nailing and supplemental gluing with a structural adhesive is required. The added bearing capacity achievable with web stiffeners is limited by the allowable bearing stresses where the stiffeners contact the bearing flange and by their mechanical connection to the web. Web stiffeners also serve the implied function of reinforcing the web against buckling. Since shear capacity usually increases proportionately with the depth, web stiffeners are very important for deep wood I-joists. For example, a 30" deep wood I-joist may only develop 20% to 30% of its shear and bearing capacity without properly attached web stiffeners at the bearing locations. This is especially important at continuous span bearing locations, where reaction magnitudes can exceed simple span reactions by an additional 25%. Web stiffeners should be cut so that a gap of at least 1/8" is between the stiffener and the top or bottom of the flange to avoid a force fit. Web stiffeners should be installed snug to the bottom flange for bearing reinforcement or snug to the top flange if under concentrated load from above. For shallow depth joists, where relatively low shear capacities are required, web stiffeners may not be needed. When larger reaction capacities are required, web stiffener reinforcement may be needed, especially where short bearing lengths are desired. Figure M7.4-4 illustrates the bearing interfaces. M7: PREFABRICATED WOOD I-JOISTS

46 36 M7: PREFABRICATED WOOD I-JOISTS Figure M7.4-4 Web Stiffener Bearing Interface Beveled End Cuts Beveled end cuts, where the end of the joist is cut on an angle (top flange does not project over the bearing, much like a fire cut), also requires special design consideration. Again the severity of the angle, web material, location of web section joints, and web stiffener application criteria effect the performance of this type of bearing condition. The specific wood I-joist manufacturers should be consulted for limits on this type of end cut. It is generally accepted that if a wood I-joist has the minimum required bearing length, and the top flange of the joist is not cut beyond the face of bearing (measured from a line perpendicular to the joist s bottom flange), there is no reduction in shear or reaction capacity. This differs from the conventional lumber provision that suggests there is no decrease in shear strength for beveled cuts of up to an angle of 45 o. The reason involves the composite nature of the wood I-joist and how the member fails in shear and or bearing. Figure M7.4-5 provides an illustration of the beveled end cut limitation. Figure M7.4-5 Beveled End Cut

47 MANUAL FOR ENGINEERED WOOD CONSTRUCTION 37 Sloped Bearing Conditions Sloped bearing conditions require design considerations different from conventional lumber. An example is a birdsmouth bearing cut (notches in the bottom flange, see Figure M7.4-6). This type of bearing should only be used on the low end bearing for wood I-joists. Another example is the use of metal joist support connectors that attach only to the web area of the joist and do not provide a bottom seat in which to bear. In general, this type of connector is not recommended for use with wood I-joists without consideration for the resulting reduced capacity. The birdsmouth cut is a good solution for the low end bearing when the slope is steep and the tangential loads are high (loads along the axis of the joist member). This assumes the quality of construction is good and the cuts are made correctly and at the right locations. This type of bearing cut requires some skill and is not easy to make, particularly with the wider flange joists. The bearing capacity, especially with high shear capacity members, may be reduced as a result of the cut since the effective flange bearing area is reduced. The notched cut will also reduce the member s shear and moment capacity at a cantilever location. An alternative to a birdsmouth cut is a beveled bearing plate matching the joist slope or special sloped seat bearing hardware manufactured by some metal connector suppliers. These alternatives also have special design considerations with steep slope applications. As the member slope increases, so does the tangential component of reaction, sometimes requiring additional flange to bearing nailing or straps to provide resistance. Figure M7.4-6 shows some examples of acceptable low end bearing conditions. Figure M7.4-6 Sloped Bearing Conditions (Low End) 7 M7: PREFABRICATED WOOD I-JOISTS

48 38 M7: PREFABRICATED WOOD I-JOISTS For the high end support, bottom flange bearing in a suitable connector or on a beveled plate is recommended. When slopes exceed 30, straps or gussets may be needed to resist the tangential component of the reaction. Support connections only to the web area of a wood I-joist, especially at the high end of a sloped application, are not generally recommended. Since a wood I-joist is comprised of a number of pieces, joints between web sections occurring near the end of the member may reduce the joist s shear capacity when not supported from the bottom flange. When a wood I-joist is supported from the web only, the closest web to web joint from the end may be stressed in tension. This could result in a joint failure with the web section pulling out of the bottom flange. Locating these internal joints away from the end of the member or applying joint reinforcements are potential remedies, but generally are not practical in the field. The best bearing solution is to provide direct support to the joist s bottom flange to avoid reductions in capacity. Figure M7.4-7 shows typical high end bearing conditions. Figure M7.4-7 Sloped Bearing Conditions (High End) Connector Design/Joist Hangers Although there are numerous hangers and connectors available that are compatible with wood I-joists, many are not. Hangers developed for conventional lumber or glulam beams often use large nails and space them in a pattern that will split the joist flanges and web stiffeners. Hanger selection considerations for wood I-joists should include nail length and diameter, nail location, wood I-joist bearing capacity, composition of the supporting member, physical fit, and load capacity. For example, hangers appropriate for a wood I-joist to glulam beam support may not be compatible for an I-joist to I-joist connection. In general, nails into the flanges should not exceed the diameter of a 10d common nail, with a recommended length no greater than 1½". Nails into web stiffeners should not exceed the diameter of a 16d common nail. Nails through the sides of the hanger, when used in combination with web stiffeners, can be used to reduce the joist s minimum required bearing length. Nails help transfer loads directly from the I-joist web into the hanger, reducing the load transferred through direct bearing in the bottom hanger seat. Hangers should be capable of providing lateral support to the top flange of the joist. This is usually accomplished by a hanger flange that extends the full depth of the joist. As a minimum, hanger support should extend to at least midheight of a joist used with web stiffeners. Some connector manufacturers have developed hangers specifically for use with wood I-joists that provide full lateral support without the use of web stiffeners. Figure M7.4-8 illustrates lateral joist support requirements for hangers. NDS Commentary section C7.3.5 also provides additional guidance on direct attachment of sheathing to the I-joist compression flange to provide lateral support.

49 MANUAL FOR ENGINEERED WOOD CONSTRUCTION 39 Figure M7.4-8 Lateral Support Requirements for Joists in Hangers Figure M7.4-9 Top Flange Hanger Support When top flange style hangers are used to support one I-joist from another, especially the wider flange I-joists, web stiffeners need to be installed tight to the bottom side of the support joist s top flanges. This prevents cross grain bending and rotation of the top flange (see Figure M7.4-9). When face nail hangers are used for joist to joist connections, nails into the support joist should extend through and beyond the web element (Figure M7.4-10). Filler blocks should also be attached sufficiently to provide support for the hanger. Again, nail diameter should be considered to avoid splitting the filler block material. Multiple I-joists need to be adequately connected together to achieve desired performance. This requires proper selection of a nailing or bolting pattern and attention to web stiffener and blocking needs. Connections should be made through the webs of the I-joists and never through the flanges. 7 M7: PREFABRICATED WOOD I-JOISTS

50 40 M7: PREFABRICATED WOOD I-JOISTS For a double I-joist member loaded from one side only, the minimum connection between members should be capable of transferring at least 50% of the applied load. Likewise, for a triple member loaded from one side only, the minimum connection between members must be capable of transferring at least 2/3 of the applied load. The actual connection design should consider the potential slip and differential member stiffness. Many manufacturers recommend limiting multiple members to three joists. Multiple I-joists with 3½" wide flanges may be further limited to two members. The low torsional resistance of most wood I-joists is also a design consideration for joist to joist connections. Eccentrically applied side loads, such as a top flange hanger hung from the side of a double joist, create the potential for joist rotation. Bottom flange restraining straps, blocking, or directly applied ceiling systems may be needed on heavily loaded eccentric connections to resist rotation. Figure M shows additional I-joist connection considerations for use with face nail hangers. Figure M Connection Requirements for Face Nail Hangers Vertical Load Transfer Bearing loads originating above the joists at the bearing location require blocking to transfer these loads around the wood I-joist to the supporting wall or foundation. This is typically the case in a multi-story structure where bearing walls stack and platform framing is used. Usually, the available bearing capacity of the joist is needed to support its reaction, leaving little if any excess capacity to support additional bearing wall loads from above. The most common type of blocking uses short pieces of wood I-joist, often referred to as blocking panels, positioned directly over the lower bearing and cut to fit in between the joists. These panels also provide lateral support for the joists and an easy means to transfer lateral diaphragm shears. The ability to transfer lateral loads (due to wind, seismic, construction loads, etc.) to shear walls or foundations below is important to the integrity of the building design. Compared with dimension lumber blocking, which usually is toe-nailed to the bearing below, wood I-joist blocking can develop higher diaphragm transfer values because of a wider member width and better nail values. Specialty products designed specifically for rim boards are pre-cut in strips equal to the joist depth and provide support for the loads from above. This solution may also provide diaphragm boundary nailing for lateral loads.

51 MANUAL FOR ENGINEERED WOOD CONSTRUCTION 41 A third method uses vertically oriented short studs, often called squash blocks or cripple blocks, on each side of the joist and cut to a length slightly longer than the depth of the joist. This method should be used in combination with some type of rim joist or blocking material when lateral stability or diaphragm transfer is required. The use of horizontally oriented sawn lumber as a blocking material is unacceptable. Wood I-joists generally do not shrink in the vertical direction due to their panel type web, creating the potential for a mismatch in height as sawn lumber shrinks to achieve equilibrium. When conventional lumber is used in the vertical orientation, shrinkage problems are not a problem because changes in elongation due to moisture changes are minimal. Figure M shows a few common methods for developing vertical load transfer. Figure M Details for Vertical Load Transfer 7 Web Holes Holes cut in the web area of a wood I-joist affect the member s shear capacity. Usually, the larger the hole, the greater the reduction in shear capacity. For this reason, holes are generally located in areas where shear stresses are low. This explains why the largest holes are generally permitted near mid-span of a member. The required spacing between holes and from the end of the member is dependent upon the specific materials and processes used during manufacturing. The allowable shear capacity of a wood I-joist at a hole location is influenced by a number of variables. These include: percentage of web removed, proximity to a vertical joint between web segments, the strength of the web to flange glue joint, the stiffness of the flange, and the shear strength of the web material. Since wood I-joists are manufactured using different processes and materials, each manufacturer should be consulted for the proper web hole design. The methodology used to analyze application loads is important in the evaluation of web holes. All load cases that will develop the highest shear at the hole location should be considered. Usually, for members resisting simple uniform design loads, the loading condition that develops the highest shear loads in the center area of a joist span involves partial span loading. Web holes contribute somewhat to increased deflection. The larger the hole the larger the contribution. Provided not too many holes are involved, the contribution is negligible. In most cases, if the manufacturer s hole criteria are followed and the number of holes is limited to three or less per span, the additional deflection does not warrant consideration. M7: PREFABRICATED WOOD I-JOISTS

52 42 M7: PREFABRICATED WOOD I-JOISTS

53 MANUAL FOR ENGINEERED WOOD CONSTRUCTION 43 M8: STRUCTURAL COMPOSITE LUMBER M8.1 General 44 M8.2 Reference Design Values 45 M8.3 Adjustment of Reference Design Values 46 M8.4 Special Design Considerations 47 8

54 44 M8: STRUCTURAL COMPOSITE LUMBER M8.1 General Product Information Structural composite lumber (SCL) products are well known throughout the construction industry. The advantages of SCL include environmental benefits from better wood fiber utilization along with higher strength, stiffness, and consistency from fiber orientation and manufacturing process control. SCL is manufactured from strips or full sheets of veneer. The process typically includes alignment of stress graded fiber, application of adhesive, and pressing the material together under heat and pressure. By redistributing natural defects and through state of the art quality control procedures, the resulting material is extremely consistent and maximizes the strength and stiffness of the wood fiber. The material is typically produced in a long length continuous or fixed press in a billet form. This is then resawn into required dimensions for use. Material is currently available in a variety of depths from 4-3/8" to 24" and thicknesses from 3/4" to 7". SCL is available in a wide range of sizes and grades. When specifying SCL products, a customer may specify on the basis of size, stress (strength), or appearance. SCL products are proprietary and are covered by code evaluation reports. Such reports should be consulted for current design information while manufacturer s literature can be consulted for design information, sizing tables, and installation recommendations. Common Uses SCL is widely used as a framing material for housing. SCL is made in different grades and with various processes and can be utilized in numerous applications. Proper design is required to optimize performance and economics. In addition to use in housing, SCL finds increasing use in commercial and industrial construction. Its high strength, stiffness, universal availability, and cost saving attributes make it a viable alternative in most low-rise construction projects. SCL is used as beams, headers, joists, rafters, studs, and plates in conventional construction. In addition, SCL is used to fabricate structural glued laminated beams, trusses, prefabricated wood I-joists, and cross-laminated timber. Availability SCL is regarded as a premium construction material and is widely available. To efficiently specify SCL for individual projects, the customer should be aware of the species and strength availability. Sizes vary with each individual product. The best source of this information is your local lumber supplier, distribution center, or SCL manufacturer. Proper design is facilitated through the use of manufacturer s literature, code reports, and software available from SCL manufacturers.

55 MANUAL FOR ENGINEERED WOOD CONSTRUCTION 45 M8.2 Reference Design Values General Bending As stated in NDS 8.2, SCL products are proprietary and each manufacturer develops design values appropriate for their products. These values are reviewed by the model building codes and published in evaluation reports and manufacturer s literature. Reference design values are used in conjunction with the adjustment factors in M8.3. Shear Design SCL is typically designed and installed as a rectangular section. Loads near supports may be reduced per NDS However, such load must be included in bearing calculations. Shear values for SCL products often change with member orientation. Bearing SCL typically has high F c and F c properties. With the higher shear and bending capacities, shorter or continuous spans are often controlled by bearing. The user is cautioned to ensure the design accounts for compression of the support material (i.e., plate) as well as the beam material. Often the plate material is of softer species and will control the design. Published bending capacities of SCL beams are determined from testing of production specimens. Adjustment for the size of the member is also determined by test. Field notching or drilling of holes is typically not allowed. Similarly, excessive nailing or the use of improper nail sizes can cause splitting that will also reduce capacity. The manufacturer should be contacted when evaluating a damaged beam. Deflection Design Deflection calculations for SCL typically are similar to provisions for other rectangular wood products (see M3.5). Values for use in deflection equations can be found in the individual manufacturer s product literature or evaluation reports. Some manufacturers might publish true E values which would require additional calculations to account for shear deflection (see NDS Appendix F). 8 M8: STRUCTURAL COMPOSITE LUMBER

56 46 M8: STRUCTURAL COMPOSITE LUMBER M8.3 Adjustment of Reference Design Values Member design capacity is the product of reference design values, adjustment factors, and section properties. Reference design values for SCL are discussed in M8.2. Adjustment factors are provided for applications outside the reference end-use conditions and for member configuration effects as specified in NDS 8.3. When one or more of the specific end use or member configuration conditions are beyond the range of the reference conditions, these adjustment factors shall be used to modify the appropriate property. Adjustment factors for the effects of moisture, temperature, member configuration, and size are provided in NDS 8.3. Additional adjustment factors can be found in the manufacturer s product literature or code evaluation report. Table M8.3-1 shows the applicability of adjustment factors for SCL in a slightly different format for the designer. Certain products may not be suitable for use in some applications or with certain treatments. Such conditions can result in structural deficiencies and may void manufacturer warranties. The manufacturer or code evaluation report should be consulted for specific information. Table M8.3-1 Applicability of Adjustment Factors for Structural Composite Lumber 1 Allowable Stress Design Load and Resistance Factor Design F b = F b C D C M C t C L C V C r F b = F b C M C t C L C V C r (2.54)(0.85) λ F t = F t C D C M C t F t = F t C M C t (2.70)(0.80) λ F v = F v C D C M C t F v = F v C M C t (2.88)(0.75) λ F c = F c C D C M C t C P F c = F c C M C t C P (2.40)(0.90) λ F c = F c C M C t C b F c = F c C M C t C b (1.67)(0.90) E = E C M C t E = E C M C t E min = E min C M C t E min = E min C M C t (1.76)(0.85) 1. See NDS for information on simultaneous application of the volume factor, C V, and the beam stability factor, C L. Bending Member Example For fully laterally supported members stressed in strong axis bending and used in a normal building environment (meeting the reference conditions of NDS 2.3 and 8.3), the adjusted design values reduce to: For ASD: F b = F b C D C V F v = F v C D F c = F c C b E = E For LRFD: F b = F b C V (2.54)(0.85) λ F v = F v (2.88)(0.75) λ F c = F c C b (1.67)(0.90) E = E Axially Loaded Member Example For axially loaded members used in a normal building environment (meeting the reference conditions of NDS 2.3 and 8.3) designed to resist tension or compression loads, the adjusted tension or compression design values reduce to: For ASD: F c = F c C D C P F t = F t C D E min = E min For LRFD: F c = F c C P (2.40)(0.90) λ F t = F t (2.70)(0.80) λ E min = E min (1.76)(0.85)

57 MANUAL FOR ENGINEERED WOOD CONSTRUCTION 47 M8.4 Special Design Considerations General With proper detailing and protection, SCL can perform well in a variety of environments. One key to proper detailing is planning for the natural shrinkage and swelling of wood members as they are subjected to various drying and wetting cycles. While moisture changes have the largest impact on lumber dimensions, some designs must also check the effects of temperature. While SCL is typically produced using dry veneer, some moisture accumulation may occur during storage. If the product varies significantly from specified dimensions, the user is cautioned from using such product as it will shrink as it dries. In addition to designing to accommodate dimensional changes and detailing for durability, another significant issue in the planning of wood structures is that of fire performance, which is covered in Chapter M16. Dimensional Changes Durability Designing for durability is a key part of the architectural and engineering design of the building. Wood exposed to high levels of moisture can decay over time. While there are exceptions such as naturally durable species, preservative-treated wood, and those locations that can completely air-dry between moisture cycles prudent design calls for a continuing awareness of the possibility of moisture accumulation. Awareness of the potential for decay is the key many design conditions can be detailed to minimize the accumulation of moisture; for other problem conditions, preservative-treated wood or naturally durable species should be specified. This section cannot cover the topic of designing for durability in detail. There are many excellent texts that devote entire chapters to the topic, and designers are advised to use this information to assist in designing difficult design areas, such as: The dimensional stability and response to temperature effects of engineered lumber is similar to that of solid sawn lumber of the same species. Some densification of the wood fiber can occur in various manufacturing processes. SCL that is densified will result in a product that has more wood fiber in a given volume and can, therefore, hold more water than a solid sawn equivalent. When soaked these products expand and dimensional changes can occur. Adhesive applied during certain processes tends to form a barrier to moisture penetration. Therefore, the material will typically take longer to reach equilibrium than its solid sawn counterpart. For given temperatures and applications, different levels of relative humidity are present. This will cause the material to move toward an equilibrium moisture content (EMC). Eventually all wood products will reach their EMC for a given environment. SCL will typically equilibrate at a lower EMC (typically 3% to 4% lower) than solid sawn lumber and will take longer to reach an ambient EMC. Normal swings in humidity during the service life of the structure should not produce noticeable dimensional changes in SCL members. More information on designing for moisture and temperature change is included in M4.4. structures in high moisture or humid conditions, where wood comes in contact with concrete or masonry, where wood members are supported in steel hangers or connectors in which condensation could collect, anywhere that wood is directly or indirectly exposed to the elements, where wood, if it should ever become wet, could not naturally dry out. This list is not intended to be all-inclusive it is merely an attempt to alert designers to special conditions that may cause problems when durability is not considered in the design. More information on detailing for durability is included in M M8: STRUCTURAL COMPOSITE LUMBER

58 48 M8: STRUCTURAL COMPOSITE LUMBER

59 MANUAL FOR ENGINEERED WOOD CONSTRUCTION 49 M9: WOOD STRUCTURAL PANELS M9.1 General 50 M9.2 Reference Design Values 50 M9.3 Adjustment of Reference Design Values 56 M9.4 Design Considerations 57 9

60 50 M9: WOOD STRUCTURAL PANELS M9.1 General Product Description Wood structural panels are wood-based panel products that have been rated for use in structural applications. Common applications for wood structural panels include roof sheathing, wall sheathing, subflooring, and single-layer flooring (combination subfloor-underlayment). Structural plywood is also manufactured in various sanded grades. Wood structural panels are classified by span ratings. Panel span ratings identify the maximum recommended support spacings in inches for specific end uses. The span rating applies when the long panel dimension or strength axis is across supports, unless the strength axis is otherwise identified. Design capacities are provided on the basis of span ratings. Sanded grades are classed according to grade and performance category and design capacities are provided on that basis. Designers must specify wood structural panels by the span ratings, performance category, grades, and constructions associated with tabulated design recommendations. Exposure durability classification must also be identified. Wood structural panel adhesive bond classification relates to moisture resistance of the glue bond, and thus to structural integrity of the panel. Bond classification of the panel does not relate to physical (erosion, ultraviolet, etc.) or biological (mold, fungal decay, insect, etc.) resistance of the panel. Exposure 1 panels may be used for applications where construction delays may be expected prior to providing protection or where exposure to the outdoors is on the underside only. Exterior bond classification indicates the glue bond is suitable for applications subject to long-term exposure to weather or moisture. Single-floor panels typically have tongue-and-groove edges. If square edge panels are specified for single-floor applications, the specification shall require lumber blocking between supports. Table M9.1-1 provides descriptions and typical uses for various panel grades and types. M9.2 Reference Design Values General Wood structural panel design capacities listed in Tables M9.2-1 and M9.2-2 are minimum for grade and span rating. Multipliers shown in each table provide adjustments in capacity for Structural I panel grades. To take advantage of these multipliers, the specifier must insure that the correct panel is used in construction. The tabulated capacities and adjustment factors are based on data from tests of panels manufactured in accordance with industry standards and which bear the trademark of a qualified inspection and testing agency. Structural panels have a strength axis direction and a cross panel direction. The direction of the strength axis is defined as the axis parallel to the orientation of OSB face strands or plywood face veneer grain and is typically the long dimension of the panel unless otherwise indicated by the manufacturer. This is illustrated in Figure M Figure M ft Typical Structural Panel with Strength Direction Across Supports Strength Direction 8-ft Typical Panel Stiffness and Strength Panel design capacities listed in Table M9.2-1 are based on flat panel bending (Figure M9.2-2) as measured by testing according to principles of ASTM D3043 Method C (large panel testing). Stiffness (EI) Panel bending stiffness is the capacity to resist deflection and is represented as EI. E is the reference modulus of elasticity of the material, and I is the moment of inertia

61 MANUAL FOR ENGINEERED WOOD CONSTRUCTION 51 of the cross section. The units of EI are lbf-in. 2 per foot of panel width. Strength (F b S) Bending strength capacity is the design maximum moment, represented as F b S. F b is the reference extreme fiber bending stress of the material, and S is the section modulus of the cross section. The units of F b S are lbf-in. per foot of panel width. Figure M9.2-2 Example of Structural Panel in Bending Table M9.1-1 Guide to Panel Use Panel Grade and Bond Classification Sheathing EXP 1 Description & Use Unsanded sheathing grade for wall, roof, subflooring, and industrial applications such as pallets and for engineering design with proper capacities. Common Performance Category (in.) 5/16, 3/8, 15/32, 1/2, 19/32, 5/8, 23/32, 3/4 OSB Panel Construction Plywood Minimum Veneer Grade Yes Yes Structural I Sheathing EXP 1 Single Floor EXP 1 Underlayment EXP 1 or EXT C-D-Plugged EXP 1 Panel grades to use where shear and crosspanel strength properties are of maximum importance. Plywood Structural I is made from all Group 1 woods. Combination subfloor-underlayment. Provides smooth surface for application of carpet and pad. Possesses high concentrated and impact load resistance during construction and occupancy. Touch-sanded. Available with tongue-and-groove edges. For underlayment under carpet and pad. Available with exterior glue. Touch-sanded or sanded. Panels with performance category of 19/32 or greater may be available with tongueand-groove edges. For built-ins, wall and ceiling tile backing. Not for underlayment. Touch-sanded. 3/8, 7/16, 15/32, 1/2, 19/32, 5/8, 23/32, 3/4 19/32, 5/8, 23/32, 3/4, 7/8, 1, 1-3/32, 1-1/8 1/4, 11/32, 3/8, 15/32, 1/2, 19/32, 5/8, 23/32, 3/4 1/2, 19/32, 5/8, 23/32, 3/4 Yes Yes Yes Yes No Yes, face C-Plugged, back D, inner D No Yes, face C-Plugged, back D, inner D 9 M9: WOOD STRUCTURAL PANELS Sanded Grades EXP 1 or EXT Marine EXT Generally applied where a high-quality surface is required. Includes A-A, A-C, A-D, B-B, B-C, and B-D grades. Superior Exterior-type plywood made only with Douglas-fir or western larch. Special solid-core construction. Available with medium density overlay (MDO) or high density overlay (HDO) face. Ideal for boat hull construction. 1/4, 11/32, 3/8, 15/32, 1/2, 19/32, 5/8, 23/32, 3/4 1/4, 11/32, 3/8, 15/32, 1/2, 19/32, 5/8, 23/32, 3/4 No Yes, face B or better, back D or better, inner C & D No Yes, face A or face B, back A or inner B

62 52 M9: WOOD STRUCTURAL PANELS Table M9.2-1 Wood Structural Panel Bending Stiffness and Strength Capacities Span Rating Stress Parallel to Strength Axis 1 Stress Perpendicular to Strength Axis 1 Plywood Plywood 3-ply 4-ply 5-ply OSB 3-ply 4-ply 5-ply OSB PANEL BENDING STIFFNESS, EI (lbf-in. 2 /ft of panel width) 24/0 66,000 66,000 66,000 60,000 3,600 7,900 11,000 11,000 24/16 86,000 86,000 86,000 78,000 5,200 11,500 16,000 16,000 32/16 125, , , ,000 8,100 18,000 25,000 25,000 40/20 250, , , ,000 18,000 39,500 56,000 56,000 48/24 NA 440, , ,000 NA 65,000 91,500 91,500 16oc 165, , , ,000 11,000 24,000 34,000 34,000 20oc 230, , , ,000 13,000 28,500 40,500 40,500 24oc NA 330, , ,000 NA 57,000 80,500 80,500 32oc NA NA 715, ,000 NA NA 235, ,000 48oc NA NA 1,265,000 1,150,000 NA NA 495, ,000 Multiplier for Structural I Panels PANEL BENDING STRENGTH, F b S (lbf-in./ft of panel width) 24/ / / / /24 NA 930 1,000 1,000 NA oc oc oc NA NA oc NA NA 1,050 1,050 NA NA oc NA NA 1,900 1,900 NA NA 1,200 1,200 Multiplier for Structural I Panels Strength axis is defined as the axis parallel to the face and back orientation of the flakes or the grain (veneer), which is generally the long panel direction, unless otherwise marked. NA - Not applicable. Atypical panel construction. Axial Capacities Axial Stiffness (EA) Panel axial stiffnesses listed in Table M9.2-2 are based on testing according to the principles of ASTM D3501 Method B. Axial stiffness is the capacity to resist axial strain and is represented as EA. E is the reference axial modulus of elasticity of the material, and A is the area of the cross section. The units of EA are pounds force per foot of panel width. Tension (F t A) Tension capacities listed in Table M9.2-2 are based on testing according to the principles of ASTM D3500 Method B. Tension capacity is given as F t A. F t is the reference axial tensile stress of the material, and A is the area of the cross section. The units of F t A are pounds force per foot of panel width.

63 MANUAL FOR ENGINEERED WOOD CONSTRUCTION 53 Table M9.2-2 Wood Structural Panel Axial Stiffness, Tension, and Compression Capacities Span Rating Stress Parallel to Strength Axis 1 Stress Perpendicular to Strength Axis 1 Plywood Plywood 3-ply 4-ply 5-ply OSB 3-ply 4-ply 5-ply OSB PANEL TENSION, F t A (lbf/ft of panel width) 24/0 2,300 2,300 3,000 2, /16 2,600 2,600 3,400 2, ,300 1,300 32/16 2,800 2,800 3,650 2,800 1,250 1,250 1,650 1,650 40/20 2,900 2,900 3,750 2,900 1,600 1,600 2,100 2,100 48/24 NA 4,000 5,200 4,000 NA 1,950 2,550 2,550 16oc 2,600 2,600 3,400 2,600 1,450 1,450 1,900 1,900 20oc 2,900 2,900 3,750 2,900 1,600 1,600 2,100 2,100 24oc NA 3,350 4,350 3,350 NA 1,950 2,550 2,550 32oc NA NA 5,200 4,000 NA NA 3,250 3,250 48oc NA NA 7,300 5,600 NA NA 4,750 4,750 Multiplier for Structural I Panels PANEL COMPRESSION, F c A (lbf/ft of panel width) 24/0 2,850 4,300 4,300 2,850 2,500 3,750 3,750 2,500 24/16 3,250 4,900 4,900 3,250 2,500 3,750 3,750 2,500 32/16 3,550 5,350 5,350 3,550 3,100 4,650 4,650 3,100 40/20 4,200 6,300 6,300 4,200 4,000 6,000 6,000 4,000 48/24 NA 7,500 7,500 5,000 NA 7,200 7,200 4,300 16oc 4,000 6,000 6,000 4,000 3,600 5,400 5,400 3,600 20oc 4,200 6,300 6,300 4,200 4,000 6,000 6,000 4,000 24oc NA 7,500 7,500 5,000 NA 7,200 7,200 4,300 32oc NA NA 9,450 6,300 NA NA 9,300 6,200 48oc NA NA 12,150 8,100 NA NA 10,800 6,750 Multiplier for Structural I Panels PANEL AXIAL STIFFNESS, EA (lbf/ft of panel width) 24/0 3,350,000 3,350,000 3,350,000 3,350,000 2,900,000 2,900,000 2,900,000 2,500, /16 3,800,000 3,800,000 3,800,000 3,800,000 2,900,000 2,900,000 2,900,000 2,700, /16 4,150,000 4,150,000 4,150,000 4,150,000 3,600,000 3,600,000 3,600,000 2,700,000 40/20 5,000,000 5,000,000 5,000,000 5,000,000 4,500,000 4,500,000 4,500,000 2,900, /24 NA 5,850,000 5,850,000 5,850,000 NA 5,000,000 5,000,000 3,300, oc 4,500,000 4,500,000 4,500,000 4,500,000 4,200,000 4,200,000 4,200,000 2,700,000 20oc 5,000,000 5,000,000 5,000,000 5,000,000 4,500,000 4,500,000 4,500,000 2,900, oc NA 5,850,000 5,850,000 5,850,000 NA 5,000,000 5,000,000 3,300, oc NA NA 7,500,000 7,500,000 NA NA 7,300,000 4,200,000 48oc NA NA 8,200,000 8,200,000 NA NA 7,300,000 4,600,000 9 M9: WOOD STRUCTURAL PANELS Multiplier for Structural I Panels Strength axis is defined as the axis parallel to the face and back orientation of the flakes or the grain (veneer), which is generally the long panel direction, unless otherwise marked. 2. The values shall be permitted to be increased to 2,900,000 lbf/ft for the calculation of the bending stiffness (EI joist ) of prefabricated wood I-joists. 3. The values shall be permitted to be increased to 4,500,000 lbf/ft for the calculation of the composite floor bending stiffness (EI composite ) of prefabricated wood I-joists. NA - Not applicable. Atypical panel construction.

64 54 M9: WOOD STRUCTURAL PANELS Compression (F c A) Compression (Figure M9.2-3) capacities listed in Table M9.2-2 are based on testing according to the principles of ASTM D3501 Method B. Compression capacity is given as F c A. F c is the reference axial compression stress of the material, and A is the area of the cross section. The units of F c A are pounds force per foot of panel width. Shear Capacities Figure M9.2-3 Structural Panel with Axial Compression Load in the Plane of the Panel Shear-in-the-Plane of the Panel (F s [Ib/Q]) Shear-in-the-plane of the panel (innerlaminer or rolling shear) capacities listed in Table M9.2-3 are based on testing according to the principles of ASTM D2718. Shear strength in the plane of the panel is the capacity to resist horizontal shear breaking loads when loads are applied or developed on opposite faces of the panel (Figure M9.2-4), as in flat panel bending. Planar shear capacity is given as F s [Ib/Q]. F s is the reference material innerlaminar shear stress, and Ib/Q is the panel cross-sectional shear constant. The units of F s [Ib/Q] are pounds force per foot of panel width. Panel Rigidity Through-the-Thickness (G v t v ) Panel rigidities listed in Table M9.2-4 are based on testing according to the principles of ASTM D2719. Panel rigidity is the capacity to resist deformation under shear through the thickness stress (Figure M9.2-5). Rigidity is given as G v t v. G v is the reference modulus of rigidity, and t v is the effective panel thickness for shear. The units of G v t v are pounds force per inch of panel depth (for vertical applications). Multiplication of G v t v by panel depth gives GA, used by designers for some applications. Panel Shear Through-the-Thickness (F v t v ) Through-the-thickness shear capacities listed in Table M9.2-4 are based on testing according to the principles of ASTM D2719. Allowable shear through-the-thickness is the capacity to resist horizontal shear breaking loads when loads are applied or developed on opposite edges of the panel (Figure M9.2-5), such as in an I-joist web. Where additional support is not provided to prevent buckling, design capacities in Table M9.2-4 are limited to sections 2 ft or less in depth. Deeper sections may require additional reductions. F v is the reference shear through-the-thickness stress of the material, and t v is the effective panel thickness for shear. The units of F v t v are pounds force per inch of shear resisting panel length. Figure M9.2-4 Shear-in-the-Plane for Wood Structural Panels Planar (Rolling) Shear Shear Area Figure M9.2-5 Through-the-Thickness Shear for Wood Structural Panels

65 MANUAL FOR ENGINEERED WOOD CONSTRUCTION 55 Table M9.2-3 Wood Structural Panel Shear-in-the-Plane Capacities Stress Parallel to Strength Axis Span Plywood Plywood Stress Perpendicular to Strength Axis Rating 3-ply 4-ply 5-ply OSB 3-ply 4-ply 5-ply OSB PANEL SHEAR-IN-THE-PLANE, F s (Ibf/Q) (lbf/ft of panel width) 24/ / / / /24 NA NA oc oc oc NA NA oc NA NA NA NA oc NA NA NA NA Multiplier for Structural I Panels NA - Not applicable. Atypical panel construction Table M9.2-4 Wood Structural Panel Rigidity and Shear Through-the- Thickness Capacities Stress Parallel to Strength Axis Stress Perpendicular to Strength Axis Span Plywood Plywood Rating 3-ply 4-ply 5-ply 1 OSB 3-ply 4-ply 5-ply 1 OSB PANEL RIGIDITY THROUGH-THE-THICKNESS, G v t v (lbf/in. of panel depth) 24/0 25,000 32,500 37,500 77,500 25,000 32,500 37,500 77,500 24/16 27,000 35,000 40,500 83,500 27,000 35,000 40,500 83,500 32/16 27,000 35,000 40,500 83,500 27,000 35,000 40,500 83,500 40/20 28,500 37,000 43,000 88,500 28,500 37,000 43,000 88,500 48/24 NA 40,500 46,500 96,000 NA 40,500 46,500 96,000 16oc 27,000 35,000 40,500 83,500 27,000 35,000 40,500 83,500 20oc 28,000 36,500 42,000 87,000 28,000 36,500 42,000 87,000 24oc NA 39,000 45,000 93,000 NA 39,000 45,000 93,000 32oc NA NA 54, ,000 NA NA 54, ,000 48oc NA NA 76, ,000 NA NA 76, ,000 Multiplier for Structural I Panels PANEL SHEAR THROUGH-THE-THICKNESS, F v t v (lbf/in. of shear-resisting panel length) 24/ / / / /24 NA NA oc oc oc NA NA oc NA NA NA NA oc NA NA NA NA Multiplier for Structural I Panels M9: WOOD STRUCTURAL PANELS 1. 5-ply applies to plywood with five or more layers. For 5-ply plywood with three layers, use G n t n values for 4-ply panels. NA - Not applicable. Atypical panel construction.

66 56 M9: WOOD STRUCTURAL PANELS M9.3 Adjustment of Reference Design Values General Adjusted panel design capacities are determined by multiplying reference capacities, as given in Tables M9.2-1 through M9.2-4, by the adjustment factors in NDS 9.3. Some adjustment factors should be obtained from the manufacturer or other approved source. In the NDS Commentary, C9.3 provides additional information on typical adjustment factors. Tabulated capacities provided in this Chapter are suitable for reference end-use conditions. Reference end-use conditions are consistent with conditions typically associated with light-frame construction. For wood structural panels, these typical conditions involve the use of full-sized untreated panels in moderate temperature and moisture exposures. Appropriate adjustment factors are provided for applications in which the conditions of use are inconsistent with reference conditions. In addition to temperature and moisture, this includes consideration of panel treatment and size effects. NDS Table lists applicability of adjustment factors for wood structural panels. Table M9.3-1 shows the applicability of adjustment factors for wood structural panels in a slightly different format for the designer. Table M9.3-1 Applicability of Adjustment Factors for Wood Structural Panels Allowable Stress Design Load and Resistance Factor Design F b S = F b S C D C M C t C s F b S = F b S C M C t C s (2.54)(0.85) λ F t A = F t A C D C M C t C s F t A = F t A C M C t C s (2.70)(0.80) λ F v t v = F v t v C D C M C t F v t v = F v t v C M C t (2.88)(0.75) λ F s (Ib/Q) = F s (Ib/Q) C D C M C t F s (Ib/Q) = F s (Ib/Q) C M C t (2.88)(0.75) λ F c A = F c A C D C M C t F c A = F c A C M C t (2.40)(0.90) λ F c = F c C M C t F c = F c C M C t (1.67)(0.90) EI = EI C M C t EA = EA C M C t G v t v = G v t v C M C t Bending Member Example For non-structural I grade wood structural panels, greater than 24" in width, loaded in bending, and used in a normal building environment (meeting the reference conditions of NDS 2.3 and 9.3), the adjusted design values reduce to: For ASD: F b S = F b S C D EI = EI For LRFD: F b S = F b S (2.54)(0.85) λ EI = EI EI = EI C M C t EA = EA C M C t G v t v = G v t v C M C t Axially Loaded Member Example For non-structural I grade wood structural panels, greater than 24" in width, axially loaded, and used in a normal building environment (meeting the reference conditions of NDS 2.3 and 4.3) designed to resist tension or compression loads, the adjusted tension or compression design values reduce to: For ASD: F c A = F c A C D F t A = F t A C D EA = EA For LRFD: F c A = F c A (2.40)(0.90) λ F t A = F t A (2.70)(0.80) λ EA = EA

67 MANUAL FOR ENGINEERED WOOD CONSTRUCTION 57 Preservative Treatment Capacities given in Tables M9.2-1 through M9.2-4 apply, without adjustment, to plywood pressure-impregnated with preservatives and redried in accordance with American Wood Protection Association (AWPA) Standard U1. OSB panels are currently recommended only for nonpressure applications of preservative treating in accordance with AWPA Standard T1. Fire Retardant Treatment The information provided in this Chapter does not apply to fire retardant treated panels. All capacities and end-use conditions for fire retardant treated panels shall be in accordance with the recommendations of the company providing the treating and redrying service. M9.4 Design Considerations Panel Edge Support Panel Spacing For certain span ratings, the maximum recommended roof span for sheathing panels is dependent upon panel edge support. Edge support may be provided by lumber blocking, tongue and groove, or panel clips when edge support is required. Table M9.4-1 summarizes the relationship between panel edge support and maximum recommended spans. Table M9.4-1 Panel Edge Support 2 Sheathing Span Rating Maximum Recommended Span (in.) With Edge Support Without Edge Support 24/ / / / / in. for 3/8 and 7/16 performance category panels, 24 in. for 15/32 and 1/2 performance category panels. 2. Additional edge support is recommended when panel widths are less than 24 inches. Edge support requirements should be obtained from the manufacturer. Long-Term Loading Wood structural panels under constant load will creep (deflection will increase) over time. Where total deflection under long-term loading must be limited, provisions of NDS are applicable. For wood structural panels in dry-service conditions, the immediate deflection due to long term loading is increased by a factor of 2.0 to account for deformation under long-term loading. For long-term loading under high moisture and/or high temperature, appropriate adjustments should be obtained from the manufacturer or an approved source. Wood-based panel products expand and contract slightly as a natural response to changes in panel moisture content. To provide for in-plane dimensional changes, panels should be installed with a 1/8" spacing at all panel end and edge joints at the time of installation. A standard 10d box nail may be used to check panel edge and panel end spacing. Minimum Nailing Minimum nailing for wood structural panel applications is shown in Table M M9: WOOD STRUCTURAL PANELS

68 58 M9: WOOD STRUCTURAL PANELS Table M9.4-2 Minimum Nailing for Wood Structural Panel Applications Nail Spacing (in.) Recommended Panel Intermediate Application Nail Size & Type Edges Supports Single Floor Glue-nailed installation 5 Ring- or screw-shank 16, 20, 24 oc, 3/4 performance category or less 6d oc, 7/8 or 1 performance category 8d , 48 oc, (32-in. span (c-c) application) 8d oc, (48-in. span (c-c) application) 8d Single Floor Nailed-only installation Ring- or screw-shank 16, 20, 24 oc, 3/4 performance category or less 6d oc, 7/8 or 1 performance category 8d , 48 oc, (32-in. span application) 8d oc, (48-in. span application) 8d Sheathing Subflooring 3 Common smooth, ring- or screw-shank 7/16 to 1/2 thick performance category 6d /8 performance category or less 8d 6 12 Thicker panels 10d 6 6 Sheathing Wall sheathing Common smooth, ring- or screw-shank or galvanized box 3 7/16 performance category or less 6d 6 12 Over 7/16 performance category 8d 6 12 Sheathing Roof sheathing Common smooth, ring- or screw-shank 3 5/16 to 1 performance category 8d Thicker panels 8d ring- or screw-shank or 10d common smooth 1. 8d common nails may be substituted if ring- or screw-shank nails are not available d ring-shank, screw-shank, or common nails may be substituted if supports are dry in accordance with NDS. 3. Other code-approved fasteners may be used. 4. For spans 48 in. or greater, space nails 6 in. at all supports. 5. Use only adhesives conforming to ASTM D3498.

69 MANUAL FOR ENGINEERED WOOD CONSTRUCTION 59 M10: CROSS- LAMINATED TIMBER M10.1 General 60 M10.2 Reference Design Values 60 M10.3 Adjustment of Reference Design Values 63 M10.4 Design Considerations 64 10

70 60 M10: CROSS-LAMINATED TIMBER M10.1 General Product Description Cross-Laminated Timber (CLT) is a prefabricated engineered wood product consisting of at least three layers of solid-sawn lumber or structural composite lumber where the adjacent layers are cross-oriented and bonded with structural adhesive to form a solid wood element. M10.2 Reference Design Values General CLT design properties shown in Tables M and M are excerpted from ANSI/APA PRG 320 Annex A and are based on products manufactured in accordance with the ANSI standard and which bear the trademark of a qualified inspection and testing agency. Table M provides allowable design properties for the parallel layers of CLT grades listed, which represent the production intended for use by the CLT manufacturers in North America and are based on the following layups: E1: 1950f-1.7E Spruce-pine-fir MSR lumber in all parallel layers and No. 3 Spruce-pine-fir lumber in all perpendicular layers E2: 1650f-1.5E Douglas fir-larch MSR lumber in all parallel layers and No. 3 Douglas fir-larch lumber in all perpendicular layers E3: 1200f-1.2E Eastern Softwoods, Northern Species, or Western Woods MSR lumber in all parallel layers and No. 3 Eastern Softwoods, Northern Species, or Western Woods lumber in all perpendicular layers E4: 1950f-1.7E Southern pine MSR lumber in all parallel layers and No. 3 Southern pine lumber in all perpendicular layers V1: No. 2 Douglas fir-larch lumber in all parallel layers and No. 3 Douglas fir-larch lumber in all perpendicular layers V2: No. 1/No. 2 Spruce-pine-fir lumber in all parallel layers and No. 3 Spruce-pine-fir lumber in all perpendicular layers V3: No. 2 Southern pine lumber in all parallel layers and No. 3 Southern pine lumber in all perpendicular layers TABLE M Allowable Design Properties (a,b,c) for the Parallel Layers of PRG 320 CLT (for use in the U.S.) Reprinted with permission of APA-The Engineered Wood Association CLT Grades F b,0 (psi) E 0 (10 6 psi) Major Strength Direction F t,0 (psi) F c,0 (psi) F v,0 (psi) F s,0 (psi) F b,90 (psi) Minor Strength Direction E 90 (10 6 psi) F t,90 (psi) F c,90 (psi) F v,90 (psi) E1 1, ,375 1, E2 1, ,020 1, E3 1, , E4 1, ,375 1, V , V , V , F s,90 (psi) For SI: 1 psi = MPa (a) See APA PRG 320 Section 4 for symbols. (b) Tabulated values are allowable lumber design values and not permitted to be increased for the lumber size adjustment factor in accordance with the NDS. The design values shall be used in conjunction with the section properties provided by the CLT manufacturer based on the actual layup used in manufacturing the CLT panel (see Table M10.2-2). (c) Custom CLT grades that are not listed in this table shall be permitted in accordance with ANSI/APA PRG 320 Section

71 MANUAL FOR ENGINEERED WOOD CONSTRUCTION 61 The allowable design capacities for these CLT grades with layups of 3, 5, and 7 layers are provided in Table M These capacities are deemed achievable using the standard laminations tabulated in the PRG 320 standard. These capacities were derived analytically using the Shear Analogy Model 1 (the calculated moment capacities in the major strength direction were further multiplied by a factor of 0.85 for conservatism) and validated by testing. The lamination thicknesses are as tabulated. Allowable tensile, compressive, and shear capacities will be developed and added to future editions of the PRG 320 standard. TABLE M Allowable Bending Capacities (a,b,c) for CLT Grades (for use in the U.S.) Reprinted with permission of APA-The Engineered Wood Association Lamination Thickness (in.) in CLT Layup Major Strength Direction Minor Strength Direction CLT Grade CLT t (in.) ^ ^ ^ F b S eff,0 (lbfft/ft) EI eff,0 (10 6 lbf -in. 2 /ft) GA eff,0 (10 6 lbf /ft) F b S eff,90 (lbf-ft /ft) EI eff,90 (10 6 lbf -in. 2 /ft) GA eff,90 (10 6 lbf /ft) E1 E2 E3 E4 V1 V2 V3 4 1/8 1 3/8 1 3/8 1 3/ , /8 1 3/8 1 3/8 1 3/8 1 3/8 1 3/ , , /8 1 3/8 1 3/8 1 3/8 1 3/8 1 3/8 1 3/8 1 3/8 18,375 1, , /8 1 3/8 1 3/8 1 3/ , /8 1 3/8 1 3/8 1 3/8 1 3/8 1 3/ , , /8 1 3/8 1 3/8 1 3/8 1 3/8 1 3/8 1 3/8 1 3/8 15, , /8 1 3/8 1 3/8 1 3/ , /8 1 3/8 1 3/8 1 3/8 1 3/8 1 3/ , /8 1 3/8 1 3/8 1 3/8 1 3/8 1 3/8 1 3/8 1 3/8 11, , /8 1 3/8 1 3/8 1 3/ , /8 1 3/8 1 3/8 1 3/8 1 3/8 1 3/ , , /8 1 3/8 1 3/8 1 3/8 1 3/8 1 3/8 1 3/8 1 3/8 18,400 1, , /8 1 3/8 1 3/8 1 3/ , /8 1 3/8 1 3/8 1 3/8 1 3/8 1 3/ , , /8 1 3/8 1 3/8 1 3/8 1 3/8 1 3/8 1 3/8 1 3/8 8,500 1, , /8 1 3/8 1 3/8 1 3/ , /8 1 3/8 1 3/8 1 3/8 1 3/8 1 3/ , , /8 1 3/8 1 3/8 1 3/8 1 3/8 1 3/8 1 3/8 1 3/8 8, , /8 1 3/8 1 3/8 1 3/ , /8 1 3/8 1 3/8 1 3/8 1 3/8 1 3/ , , /8 1 3/8 1 3/8 1 3/8 1 3/8 1 3/8 1 3/8 1 3/8 9,200 1, , For SI: 1 in. = 25.4 mm; 1 ft = mm; 1 lbf = N (a) See ANSI/APA PRG 320 Section 4 for symbols. (b) This table represents one of many possibilities that the CLT could be manufactured by varying lamination grades, thicknesses, orientations, and layer arrangements in the layup. (c) Custom CLT grades that are not listed in this table shall be permitted in accordance with ANSI/APA PRG 320 Section M10: CROSS-LAMINATED TIMBER 1 Gagnon, S. and M. Popovski Structural Design of Cross-Laminated Timber Elements. In Chapter 3, CLT Handbook. FPInnovations, Canada.

72 62 M10: CROSS-LAMINATED TIMBER CLT Stiffness and Strength CLT stiffness and strength design capacities are based on flat panel bending (Figure M10.2-1) according to principles of ANSI/APA PRG 320. Figure M CLT Panel with Axial Compression Load in the Plane of the Panel Figure M Example of CLT Panel in Bending Strength, F b (S eff ) Bending strength capacity is the design maximum moment, represented as (F b S eff ). F b is the reference extreme fiber bending stress, and S eff is the effective section modulus of the cross section based on the layup used in the manufacturing process. The units of F b S eff are lbf-in. per foot of panel width. Bending Stiffness for Deflection Calculations, (EI) app CLT apparent bending stiffness is the capacity to resist deflection and is represented as (EI) app. The apparent stiffness is based on the layup used in the manufacturing process and is calculated using published (EI) eff values adjusted per the NDS. The units of EI are lbf-in. 2 per foot of panel width. CLT Axial Capacities Tension, Ft(A parallel ) Tension capacities are based on the principles of ANSI/ APA PRG 320. Tension capacity is given as F t (A parallel ). F t is the reference axial tensile stress of the material, and A parallel is the area of the cross section with fibers parallel to the load direction. The units of F t (A parallel ) are pounds force per foot of panel width. This property can be obtained from the CLT manufacturer or an approved source. Compression, Fc(A parallel ) Compression capacities (Figure M10.2-2) are based on principles of APA PRG 320. Compression capacity is given as F c (A parallel ). F c is the reference axial compression stress of the material and A parallel is the area of the cross section with fibers parallel to the load direction. The units of F c (A parallel ) are pounds force per foot of panel width. Bending Stiffness for Buckling Stability Calculations, (EI) app-min CLT apparent bending stiffness for panel buckling stability calculations is represented as (EI) app-min. The apparent bending stiffness is based on the layup used in the manufacturing process. The units of EI are lbf-in. 2 per foot of panel width. This property can be obtained from the CLT manufacturer or an approved source. Bearing, Fc (A) Bearing capacities are based on compression perpendicular to grain values of the side grain of the CLT panels and the total bearing area of all wood. This property can be obtained from the CLT manufacturer or an approved source. As with solid sawn lumber, compression perpendicular to grain design values are permitted to be multiplied by the bearing area factor specified in NDS CLT Shear Capacities Shear-in-the-Plane of the Panel, Fs(Ib/Q) eff Shear-in-the-plane of the panel (planar or rolling shear) capacities are based on the principles of ANSI/APA PRG 320. Shear strength in the plane of the panel is the capacity to resist horizontal shear breaking loads when loads are applied or developed on opposite faces of the panel (Figure M10.2-3), as in flat panel bending. Planar shear capacity is given as F s (Ib/Q) eff. F s is the reference material innerlaminar shear stress, and (Ib/Q) eff is the effective CLT cross-sectional shear constant. The units of F s (Ib/Q) eff are pounds force per foot of panel width.

73 MANUAL FOR ENGINEERED WOOD CONSTRUCTION 63 Figure M Shear-in-the-Plane for CLT Panels Planar (Rolling) Shear F v is the reference shear through-the-thickness stress of the material, and t v is the panel thickness for shear. The units of F v (t v ) are pounds force per inch of shear resisting panel length. This property can be obtained from the CLT manufacturer or an approved source. Figure M Through-the- Thickness Shear for CLT Panels Shear Area Shear Through-the-Thickness, F v (t v ) Through-the-thickness shear capacities are based on the principles of ANSI/APA PRG 320. Allowable shear through-the-thickness is the capacity to resist horizontal shear breaking loads when loads are applied or developed on opposite edges of the panel (Figure M10.2-4). M10.3 Adjustment of Reference Design Values General Adjusted CLT design capacities are determined by multiplying reference capacities by the adjustment factors in NDS Some adjustment factors should be obtained from the manufacturer or other approved source. In the NDS Commentary, C10.3 provides additional information on typical adjustment factors. Tabulated capacities provided in the manufacturer s literature are suitable for reference end-use conditions. For CLT, these typical conditions involve the use of untreated products in moderate temperature and moisture exposures. Appropriate adjustment factors are provided for applications in which the conditions of use are inconsistent with reference conditions. In addition to temperature and moisture, this includes load duration, beam stability, column stability, and bearing area adjustments. NDS Table lists applicability of adjustment factors for cross-laminated timber. Table M shows the applicability of adjustment factors for cross-laminated timber in an equation format. Table M Applicability of Adjustment Factors for Cross-Laminated Timber Allowable Stress Design Load and Resistance Factor Design F b (S eff ) = F b (S eff ) C D C M C t C L F b (S eff ) = F b (S eff ) C M C t C L (2.54)(0.85) λ F t (A parallel ) = F t (A parallel ) C D C M C t F t (A parallel ) = F t (A parallel ) C M C t (2.70)(0.80) λ F v t v = F v t v C D C M C t F v t v = F v t v C M C t (2.88)(0.75) λ F s (Ib/Q) eff = F s (Ib/Q) eff C M C t F s (Ib/Q) eff = F s (Ib/Q) eff C M C t (2.88)(0.75) F c (A parallel ) = F c (A parallel ) C D C M C t C P F c (A parallel ) = F c (A parallel ) C M C t C P (2.40)(0.90) λ F c (A) = F c (A) C M C t C b F c (A) = F c (A) C M C t C b (1.67)(0.90) (EI) app = (EI) app C M C t (EI) app = (EI) app C M C t (EI) app-min = (EI) app-min C M C t (EI) app-min = (EI) app-min C M C t (1.76)(0.85) 10 M10: CROSS-LAMINATED TIMBER

74 64 M10: CROSS-LAMINATED TIMBER Bending Member Example For cross-laminated timber, loaded in bending, and used in a normal building environment (meeting the reference conditions of NDS 2.3 and 10.3), the adjusted design values reduce to: For ASD: F b (S eff ) = F b (S eff ) C D F c (A) = F c (A) C b (EI) app = (EI) app For LRFD: F b (S eff ) = F b (S eff ) (2.54)(0.85) λ F c (A) = F c (A) C b (1.67)(0.90) (EI) app = (EI) app Axially Loaded Member Example For cross-laminated timber, axially loaded, and used in a normal building environment (meeting the reference conditions of NDS 2.3 and 10.3) designed to resist tension or compression loads, the adjusted tension or compression design values reduce to: For ASD: F c (A parallel ) = F c (A parallel ) C D C P F t (A parallel ) = F t (A parallel ) C D For LRFD: F c (A parallel ) = F c (A parallel ) C P (2.40)(0.90) λ F t (A parallel ) = F t (A parallel ) (2.70)(0.80) λ Preservative Treatment The information provided in this chapter does not apply to preservative treated CLT. All capacities and enduse conditions for preservative treated CLT shall be in accordance with the recommendations of the manufacturer. Fire Retardant Treatment The information provided in this chapter does not apply to fire retardant treated CLT. All capacities and end-use conditions for fire retardant treated CLT shall be in accordance with the recommendations of the company providing the treating and redrying service. M10.4 Design Considerations Connections Connections used in cross-laminated timber shall be in accordance with applicable NDS connection chapters or manufacturers recommendations. Long-Term Loading Cross-laminated timber under constant load will creep (deflection will increase) over time. Where total deflection under long-term loading must be limited, provisions of NDS are applicable. For CLT in dry-service conditions, the immediate deflection due to long-term loading is increased by a factor of 2.0 to account for deformation under long-term loading. For long-term loading under high moisture and/or high temperature, appropriate adjustments should be obtained from the manufacturer or an approved source.

75 MANUAL FOR ENGINEERED WOOD CONSTRUCTION 65 M11: MECHANICAL CONNECTIONS M11.1 General 66 M11.2 Reference Design Values 67 M11.3 Adjustment of Reference Design Values 67 M11.4 Typical Connection Details 68 M11.5 Pre-Engineered Metal Connectors 76 11

76 66 M11: MECHANICAL CONNECTIONS M11.1 General This Chapter covers design of connections between wood members using metal fasteners. Several common connection types are outlined below. Dowel-Type (Nails, Bolts, Screws, Pins) These connectors rely on metal-to-wood bearing for transfer of lateral loads and on friction or mechanical interfaces for transfer of axial (withdrawal) loads. They are commonly available in a wide range of diameters and lengths. More information is provided in Chapter M12. Split Rings and Shear Plates These connectors rely on their geometry to provide larger metal-to-wood bearing areas per connector. Both are installed into precut grooves or daps in the members. More information is provided in Chapter M13. Timber Rivets Timber rivets are a dowel-type connection, however, because the ultimate load capacity of such connections are limited by rivet bending and localized crushing of wood at the rivets or by the tension or shear strength of the wood at the perimeter of the rivet group, a specific design procedure is required. Timber rivet design loads are based on the lower of the maximum rivet bending load and the maximum load based on wood strength. Chapter M13 contains more information on timber rivet design. designed, metal connector manufacturers have several categories of connectors that do not fit the categories above, including: framing anchors hold down devices straps and ties These connectors are also generally proprietary connectors. See the manufacturer s literature or M11.4 for more information regarding design. Connections are designed so that no applicable capacity is exceeded under loads. Strength criteria include lateral or withdrawal capacity of the connection, and tension or shear in the metal components. Some types of connections also include compression perpendicular to grain as a design criteria. Users should note that design of connections may also be controlled by serviceability limitations. These limitations are product specific and are discussed in specific product chapters. Stresses in Members at Connections Local stresses in connections using multiple fasteners can be evaluated in accordance with NDS Appendix E. Structural Framing Connections Structural framing connections provide a single-piece connection between two framing members. They generally consist of bent or welded steel, carrying load from the supported member (through direct bearing) into the supporting member (by hanger flange bearing, fastener shear, or a combination of the two). Structural framing connections are proprietary connectors and are discussed in more detail in M11.4. Other Connectors Just as the number of possible building geometries is limitless, so too is the number of possible connection geometries. In addition to providing custom fabrication of connectors to meet virtually any geometry that can be

77 MANUAL FOR ENGINEERED WOOD CONSTRUCTION 67 M11.2 Reference Design Values Reference design values for mechanical connections are provided in various sources. The NDS contains reference design values for dowel-type connections such as nails, bolts, lag screws, wood screws, split rings, shear plates, drift bolts, drift pins, and timber rivets. Pre-engineered metal connectors are proprietary and reference design values are provided in code evaluation reports. More information on their use is provided in M11.5. Metal connector plates are proprietary connectors for trusses, and reference design values are provided in code evaluation reports. Staples and many power-driven fasteners are proprietary, and reference design values are provided in code evaluation reports. M11.3 Adjustment of Reference Design Values To generate connection design capacities, reference design values for connections are multiplied by adjustment factors per NDS Applicable adjustment factors for connections are defined in NDS Table Table M shows the applicability of adjustment factors for connections in a slightly different format for the designer. Table M Applicability of Adjustment Factors for Mechanical Connections 1 Allowable Stress Design Load and Resistance Factor Design Lateral Loads Dowel-Type Fasteners Z = Z C D C M C t C g C C eg C di C tn Z = Z C M C t C g C C eg C di C tn (3.32)(0.65) λ Split Ring and Shear P = P C D C M C t C g C C d C st P = P C M C t C g C C d C st (3.32)(0.65) λ Plate Connectors Q = Q C D C M C t C g C C d Q = Q C M C t C g C C d (3.32)(0.65) λ Timber Rivets P = P C D C M C t C st P = P C M C t C st (3.32)(0.65) λ Q = Q C D C M C t C C st Q = Q C M C t C C st (3.32)(0.65) λ Spike Grids Z = Z C D C M C t C Z = Z C M C t C (3.32)(0.65) λ Withdrawal Loads Nails, Spikes, Lag Screws, Wood Screws, and Drift Pins W = W C D C M C t C eg C tn Z = Z C M C t C eg C tn (3.32)(0.65) λ 1. See NDS Table footnotes for additional guidance on application of adjustment factors for mechanical connections. The following connection product chapters contain examples of the application of adjustment factors to reference design values: Chapter M12 dowel-type fasteners, Chapter M13 split ring and shear plate connectors, Chapter M14 timber rivets. 11 M11: MECHANICAL CONNECTIONS

78 68 M11: MECHANICAL CONNECTIONS M11.4 Typical Connection Details General Concepts of Well- Designed Connections Connections must obviously provide the structural strength necessary to transfer loads. Well-designed connections hold the wood members in such a manner that shrinkage/swelling cycles do not induce splitting across the grain. Well-designed connections also minimize regions that might collect moisture providing adequate clearance for air movement to keep the wood dry. Finally, well-designed connections minimize the potential for tension perpendicular to grain stresses either under design conditions or under unusual loading conditions. The following connection details (courtesy of the Canadian Wood Council) are organized into nine groups: 1. Beam to concrete or masonry wall connections 2. Beam to column connections 3. Column to base connections 4. Beam to beam connections 5. Cantilever beam connections 6. Arch peak connections 7. Arch base to support 8. Moment splice 9. Problem connections 1. Beam on shelf in wall. The bearing plate distributes the load and keeps the beam from direct contact with the concrete. Steel angles provide uplift resistance and can also provide some lateral resistance. The end of the beam should not be in direct contact with the concrete. 2. Similar to detail 1 with a steel bearing plate only under the beam. Many of the detail groups begin with a brief discussion of the design challenges pertinent to the specific type of connection. Focusing on the key design concepts of a broad class of connections often leads to insights regarding a specific detail of interest. Group 1. Beam to Concrete or Masonry Wall Connections Design concepts. Concrete is porous and wicks moisture. Good detailing never permits wood to be in direct contact with concrete. 3. Similar to detail 1 with slotted holes to accommodate slight lateral movement of the beam under load. This detail is more commonly used when the beam is sloped, rather than flat.

79 MANUAL FOR ENGINEERED WOOD CONSTRUCTION 69 Group 2. Beam to Column Connections Design concepts. All connections in the group must hold the beam in place on top of the column. Shear transfer is reasonably easy to achieve. Some connections must also resist some beam uplift. Finally, for cases in which the beam is spliced, rather than continuous over the column, transfer of forces across the splice may be required. 6. Custom welded column caps can be designed to transfer shear, uplift, and splice forces. Note design variations to provide sufficient bearing area for each of the beams and differing plate widths to accommodate differences between the column and the beam widths. 4. Simple steel dowel for shear transfer. 7. Combinations of steel angles and straps, bolted and screwed, to transfer forces. 5. Concealed connection in which a steel plate is inserted into a kerf in both the beam and the column. Transverse pins or bolts complete the connection. 8. A very common connection beam seat welded to the top of a steel column. 11 M11: MECHANICAL CONNECTIONS

80 70 M11: MECHANICAL CONNECTIONS 9. When both beams and columns are continuous and the connection must remain in-plane, either the beam or the column must be spliced at the connection. In this detail the column continuity is maintained. Optional shear plates may be used to transfer higher loads. Note that, unless the bolt heads are completely recessed into the back of the bracket, the beam end will likely require slotting. In a building with many bays, it may be difficult to maintain dimensions in the beam direction when using this connection. 11A. Similar to details 1 and 2. 11B. Alternate to detail 11A. Group 3. Column to Base Connections Design concepts. Since this is the bottom of the structure, it is conceivable that moisture from some source might run down the column. Experience has shown that base plate details in which a steel shoe is present can collect moisture that leads to decay in the column. 12. Similar to detail Similar to detail 4, with a bearing plate added. Group 4. Beam to Beam Connections Design concepts. Many variations of this type of connection are possible. When all members are flat and their tops are flush, the connection is fairly straightforward. Slopes and skews require special attention to fabrication dimensions well-designed connections provide adequate clearance to insert bolts or other connectors and also provide room to grip and tighten with a wrench. Especially for sloped members, special attention is required to visualize the stresses induced as the members deflect under load some connections will induce large perpendicular to grain stresses in this mode.

81 MANUAL FOR ENGINEERED WOOD CONSTRUCTION Bucket-style welded bracket at a cross junction. The top of the support beam is sometimes dapped to accommodate the thickness of the steel. suspended beam, permitting plugging of the holes after the pin is installed. Note that the kerf in the suspended beam must accommodate not only the width of the steel plate, but also the increased width at the fillet welds. 14. Face-mounted hangers are commonly used in beam to beam connections. In a cross junction special attention is required to fastener penetration length into the carrying beam (to avoid interference from other side). 17. Similar to detail 13, with somewhat lower load capacity. 18. Clip angle to connect crossing beam. 15. Deep members may be supported by fairly shallow hangers in this case, through-bolted with shear plates. Clip angles are used to prevent rotation of the top of the suspended beam. Note that the clip angles are not connected to the suspended beam doing so would restrain a deep beam from its natural across-the-grain shrinking and swelling cycles and would lead to splits. 19. Special detail to connect the ridge purlin to sloped members or to the peak of arch members. 11 M11: MECHANICAL CONNECTIONS 16. Concealed connections similar to detail 5. The suspended beam may be dapped on the bottom for a flush connection. The pin may be slightly narrower than the

82 72 M11: MECHANICAL CONNECTIONS 20A. Similar to detail 19, but with the segments of the ridge purlin set flush with the other framing. 23. Similar to detail 22, with added shear plate. 20B. Alternate to detail 20A. 24. Similar to detail 22 for low slope arches. Side plates replace the threaded rod. Group 5. Cantilever Beam Connections 21. Hinge connector transfers load without need to slope cut member ends. Beams are often dapped top and bottom for a flush fit. Group 6. Arch Peak Connections Group 7. Arch Base to Support Design concepts. Arches transmit thrust into the supporting structure. The foundation may be designed to resist this thrust or tie rods may be used. The base detail should be designed to accommodate the amount of rotation anticipated in the arch base under various loading conditions. Elastomeric bearing pads can assist somewhat in distributing stresses. As noted earlier, the connection should be designed to minimize any perpendicular to grain stresses during the deformation of the structure under load. 25. Welded shoe transmits thrust from arch to support. Note that inside edge of shoe is left open to prevent collection of moisture. 22. Steep arches connected with a rod and shear plates.

83 MANUAL FOR ENGINEERED WOOD CONSTRUCTION Arch base fastened directly to a steel tie beam in a shoe-type connection. Group 8. Moment Splice Design concepts. Moment splices must transmit axial tension, axial compression, and shear. They must serve these functions in an area of the structure where structural movement may be significant thus, they must not introduce cross-grain forces if they are to function properly. 29. Separate pieces of steel each provide a specific function. Top and bottom plate transfer axial force, pressure plates transfer direct thrust, and shear plates transmit shear. 27. Similar to detail 25. This more rigid connection is suitable for spans where arch rotation at the base is small enough to not require the rotational movement permitted in detail 25. Note that, although the shoe is boxed a weep slot is provided at the inside face. 30. Similar to detail 29. Connectors on side faces may be easier to install, but forces are higher because moment arm between steel straps is less than in detail For very long spans or other cases where large rotations must be accommodated, a true hinge connection may be required. Group 9. Problem Connections Hidden column base. It is sometimes preferable architecturally to conceal the connection at the base of the column. In any case it is crucial to detail this connection to minimize decay potential. 11 M11: MECHANICAL CONNECTIONS

84 74 M11: MECHANICAL CONNECTIONS 31A. Similar to detail 11, but with floor slab poured over the top of the connection. THIS WILL CAUSE DECAY AND IS NOT A RECOMMENDED DETAIL! 32B. As an alternative to detail 32A, smaller plates will transmit forces, but they do not restrain the wood from its natural movements. 31B. Alternate to detail 31A. Notched beam bearing. Depth limitations sometimes cause detailing difficulties at the beam supports. A simple solution is to notch the beam at the bearing. This induces large tension perpendicular to grain stresses and leads to splitting of the beam at the root of the notch. 33A. Notching a beam at its bearing may cause splits. THIS DETAIL IS NOT RECOMMENDED! Full-depth side plates. It is sometimes easier to fabricate connections for deep beams from large steel plates rather than having to keep track of more pieces. Lack of attention to wood s dimensional changes as it breathes may lead to splits. 32A. Full-depth side plates may appear to be a good connection option. Unfortunately, the side plates will remain fastened while the wood shrinks over the first heating season. Since it is restrained by the side plates, the beam may split. THIS DETAIL IS NOT RECOMMENDED! 33B. Alternate to detail 33A.

85 MANUAL FOR ENGINEERED WOOD CONSTRUCTION 75 34A. This sloped bearing with a beam that is not fully supported may also split under load. THIS DETAIL IS NOT RECOMMENDED! 35B. As an alternative to detail 35A, the plates may be extended and the connection made to the upper half of the beam. 34B. Alternate to detail 34A. Hanger to side of beam. See full-depth side plates discussion. 36A. Deep beam hangers that have fasteners installed in the side plates toward the top of the supported beam may promote splits at the fastener group should the wood member shrink and lift from the bottom of the beam hanger because of the support provided by the fastener group. THIS DETAIL IS NOT RECOMMENDED! Hanging to underside of beam. Sometimes it is advantageous to hang a load from the underside of a beam. This is acceptable as long as the hanger is fastened to the upper half of the beam. Fastening to the lower half of the beam may induce splits A. Connecting a hanger to the lower half of a beam that pulls downward may cause splits. THIS DETAIL IS NOT RECOMMENDED! 36B. Alternate to detail 36A. M11: MECHANICAL CONNECTIONS

86 76 M11: MECHANICAL CONNECTIONS M11.5 Pre-Engineered Metal Connectors Product Information Pre-engineered metal connectors for wood construction are commonly used in all types of wood construction. There are numerous reasons for their widespread use. Connectors often make wood members easier and faster to install. They increase the safety of wood construction, not only from normal loads, but also from natural disasters such as earthquakes and high winds. Connectors make wood structures easier to design by providing simpler connections of known load capacity. They also allow for the use of more cost-effective engineered wood members by providing the higher capacity connections often required by the use of such members. In certain locations, model building codes specifically require connectors or hangers. Metal connectors are usually manufactured by stamping sheets or strips of steel, although some heavy hangers are welded together. Different thicknesses and grades of steel are used, depending on the required capacity of the connector. Some metal connectors are produced as proprietary products which are covered by evaluation reports. Such reports should be consulted for current design information, while the manufacturer s literature can be consulted for additional design information and detailed installation instructions. Common Uses Pre-engineered metal connectors for wood construction are used throughout the world. Connectors are used to resist vertical dead, live, and snow loads; uplift loads from wind; and lateral loads from ground motion or wind. Almost any type of wood member may be fastened to another using a connector. Connectors may also be used to fasten wood to other materials, such as concrete, masonry, or steel. Availability Connectors are manufactured in varying load capacities, sizes, and configurations to fit a wide range of applications. A variety of connectors are widely available through lumber suppliers. Because of the wide variety of available connectors, a generic design document such as this must be limited in its scope for simplicity s sake. Design values for specific connectors are available from the connector manufacturer.

87 MANUAL FOR ENGINEERED WOOD CONSTRUCTION 77 Types of Connectors There are many different types of connectors, due to the many different applications in which connectors may be used. The following sections list the most common types of connectors. Face Mount Joist Hangers Face mount joist hangers install on the face of the supporting member, and rely on the shear capacity of the nails to provide holding power. Although referred to as joist hangers, these connectors may support other horizontal members subject to vertical loads, such as beams or purlins. Top Flange Joist Hangers Top flange joist, beam, and purlin hangers rely on bearing of the top flange onto the top of the supporting member, along with the shear capacity of any fasteners that are present in the face. Although referred to as joist hangers, these connectors may support other horizontal members subject to vertical loads, such as beams or purlins. Bent-style Joist, Beam, and Purlin Hanger* Top Flange I-joist Hanger* Face Mount Joist Hanger Heavy Face Mount Joist Hanger S tr ong- Tie SIMPSON Welded-type Purlin, Heavy Welded Beam Beam, and Joist Hanger* Hanger (Saddle Type) Slope- and Skew- Face Mount Adjustable Joist Hanger I-Joist Hanger* * Joists shall be provided with lateral support at points of bearing to prevent rotation. Sometimes this restraint can be provided by the hangers. 11 M11: MECHANICAL CONNECTIONS

88 @ 78 M11: MECHANICAL CONNECTIONS Adjustable Style Hanger Adjustable style joist and truss hangers have straps which can be either fastened to the face of a supporting member, similar to a face mount hanger, or wrapped over the top of a supporting member, similar to a top flange hanger. Seismic and Hurricane Ties Seismic and hurricane ties are typically used to connect two members that are oriented 90º from each other. These ties resist forces through the shear capacity of the nails in the members. These connectors may provide resistance in three dimensions. Adjustable Style Truss Hangers Seismic and Hurricane Ties Connecting Roof Framing to Top Plates Flat Straps Flat straps rely on the shear capacity of the nails in the wood members to transfer load. Hold Downs and Tension Ties Hold downs and tension ties usually bolt to concrete or masonry, and connect wood members to the concrete or masonry through the shear resistance of either nails, screws, or bolts. They may also be used to connect two wood members together. Strap Used to Transfer Uplift Forces Strap Used to Transfer Lateral Forces Hold Down Tension Tie

89 MANUAL FOR ENGINEERED WOOD CONSTRUCTION 79 Embedded Type Anchors Embedded anchors connect a wood member to concrete or masonry. One end of the connector embeds in the concrete or masonry, and the other end connects to the wood through the shear resistance of the nails or bolts. type of fasteners to be used corrosion resistance desired appearance desired Once the listed information is known, proper selection is facilitated through the use of manufacturer s literature, code evaluation reports, and software available from connector manufacturers. This Manual provides guidance for specifying preengineered metal connectors to satisfy specific design criteria for a given application. Embedded Truss Anchor Embedded Nailed Hold Down Strap Connection Details Connections, including pre-engineered metal connections, must provide the structural strength necessary to transfer loads. Well-designed connections hold wood members in such a manner that shrinkage/swelling cycles do not induce splitting across the grain. Well-designed connections also minimize collection of moisture providing adequate clearance for air movement to keep the wood dry. Finally, well-designed connections minimize the potential for tension perpendicular to grain stresses either under design conditions or under unusual loading conditions. Section M10.4 contains general concepts of well-designed connections, including over 40 details showing acceptable and unacceptable practice. Other Considerations Product Selection Purlin Anchor Proper choice of connectors is required to optimize performance and economics. The selection of a connector will depend on several variables. These include the following: capacity required size and type of members being connected species of wood being connected slope and/or skew of member connector type preference With proper selection and installation, structural connectors will perform as they were designed. However, proper selection and installation involves a variety of items that both the designer and the installer must consider including the general topics of: the wood members being connected; the fasteners used; and the connectors themselves. These items are discussed in the following sections. This Manual does not purport to address these topics in an all-inclusive manner it is merely an attempt to alert designers to the importance of selection and installation details for achieving the published capacity of the connector. Wood Members The wood members being connected have an impact on the capacity of the connection. The following are important items regarding the wood members themselves: The species of wood must be the same as that for which the connector was rated by the manufacturer. Manufacturers test and publish allowable design values only for certain species of wood. For other species, consult with the connector manufacturer. 11 M11: MECHANICAL CONNECTIONS

90 80 M11: MECHANICAL CONNECTIONS The wood must not split when the fastener is installed. A fastener that splits the wood will not take the design load. If wood tends to split, consider pre-boring holes using a diameter not exceeding 3/4 of the nail diameter. Pre-boring requirements for screws and bolts are provided in the NDS. Wood can shrink and expand as it loses and gains moisture. Most connectors are manufactured to fit common dry lumber dimensions. Other dimensions may be available from the manufacturer. Where built-up lumber (multiple members) is installed in a connector, the members must be fastened together prior to installation of the connector so that the members act as a single unit. The dimensions of the supporting member must be sufficient to receive the specified fasteners. Most connectors are rated based on full penetration of all specified fasteners. Refer to the connector manufacturer for other situations. Bearing capacity of the joist or beam should also be evaluated to ensure adequate capacity. Fasteners Most wood connectors rely on the fasteners to transfer the load from one member to the other. Therefore, the choice and installation of the fasteners is critical to the performance of the connector. The following are important items regarding the fasteners used in the connector: Connectors Finally, the condition of the connector itself is critical to how it will perform. The following are important items regarding the connector itself: Connectors may not be modified in the field unless noted by the manufacturer. Bending steel in the field may cause fractures at the bend line, and fractured steel will not carry the rated load. Modified connectors may be available from the manufacturer. Not all modifications are tested by all manufacturers. Contact the manufacturer to verify loads on modified connectors. In general, all holes in connectors should be filled with the nails specified by the manufacturer. Contact the manufacturer regarding optional nail holes and optional loads. Different environments can cause corrosion of steel connectors. Always evaluate the environment where the connector will be installed. Connectors are available with differing corrosion resistances. Contact the manufacturer for availability. Fasteners must be at least the same corrosion resistance as that chosen for the connector. All fasteners specified by the manufacturer must be installed to achieve the published value. The size of fastener specified by the manufacturer must be installed. Most manufacturers specify common nails, unless otherwise noted. The fastener must have at least the same corrosion resistance as the connector. Bolts must generally be structural quality bolts, equal to or better than ANSI/ASME Standard B Bolt holes must be a minimum of 1/32" and a maximum of 1/16" larger than the bolt diameter. Fasteners must be installed prior to loading the connection. Power-driven fasteners may deflect and injure the operator or others. Nail tools may be used to install connectors, provided the correct quantity and type of nails are properly installed in the manufacturer s nail holes. Nail tools with nail hole-locating mechanisms should be used. Follow the nail tool manufacturer s instructions and use the appropriate safety equipment.

91 MANUAL FOR ENGINEERED WOOD CONSTRUCTION 81 M12: DOWEL- TYPE FASTENERS M12.1 General 82 M12.2 Reference Withdrawal Design Values 82 M12.3 Reference Lateral Design Values 82 M12.4 Combined Lateral and Withdrawal Loads 82 M12.5 Adjustment of Reference Design Values 83 M12.6 Multiple Fasteners 83 12

92 82 M12: DOWEL-TYPE FASTENERS M12.1 General This Chapter covers design of connections between wood members using metal dowel-type (nails, bolts, lag screws, wood screws, drift pins) fasteners. These connectors rely on metal-to-wood bearing for transfer of lateral loads and on friction or mechanical interfaces for transfer of axial (withdrawal) loads. They are commonly available in a wide range of diameters and lengths. M12.2 Reference Withdrawal Design Values The basic design equation for dowel-type fasteners under withdrawal loads is: W p R W where: W = adjusted withdrawal design value R W = axial (withdrawal) force p = depth of fastener penetration into wood member Reference withdrawal design values are tabulated in NDS Chapter 12. M12.3 Reference Lateral Design Values The basic equation for design of dowel-type fasteners under lateral load is: Z R Z where: Z = adjusted lateral design value R Z = lateral force Reference lateral design values are tabulated in NDS Chapter 12. M12.4 Combined Lateral and Withdrawal Loads Lag screws, wood screws, nails, and spikes resisting combined lateral and withdrawal loads shall be designed in accordance with NDS 12.4.

93 MANUAL FOR ENGINEERED WOOD CONSTRUCTION 83 M12.5 Adjustment of Reference Design Values Dowel-type connections must be designed by applying all applicable adjustment factors to the reference withdrawal design value or reference lateral design value for the connection. NDS Table lists all applicable adjustment factors for dowel-type connectors. Table M shows the applicability of adjustment factors for dowel-type fasteners in a slightly different format for the designer. Table M Applicability of Adjustment Factors for Dowel-Type Fasteners 1 Allowable Stress Design Load and Resistance Factor Design Lateral Loads Dowel-Type Fasteners Z = Z C D C M C t C g C C eg C di C tn Z = Z C M C t C g C C eg C di C tn (3.32)(0.65) λ Withdrawal Loads Nails, Spikes, Lag Screws, Wood Screws, and Drift Pins W = W C D C M C t C eg C tn Z = Z C M C t C eg C tn (3.32)(0.65) λ 1. See NDS Table footnotes for additional guidance on application of adjustment factors for dowel-type fasteners. Example of a Dowel-Type Fastener Loaded Laterally Example of a Dowel-Type Fastener Loaded in Withdrawal For a single dowel-type fastener installed in side grain perpendicular to the length of the wood member, meeting the end and edge distance and spacing requirements of NDS , used in a normal building environment (meeting the reference conditions of NDS 2.3 and 11.3), and not a nail or spike in diaphragm construction, the general equation for Z reduces to: for ASD: Z = Z C D for LRFD: Z = Z (3.32)(0.65) λ For a single dowel-type fastener installed in side grain perpendicular to the length of the wood member, used in a normal building environment (meeting the reference conditions of NDS 2.3 and 11.3), the general equation for W reduces to: for ASD: W = W C D for LRFD: W = W (3.32)(0.65) λ Installation Requirements M12: DOWEL-TYPE FASTENERS 12 To achieve stated design values, connectors must comply with installation requirements such as spacing of connectors, minimum edge and end distances, proper drilling of lead holes, and minimum fastener penetration. M12.6 Multiple Fasteners Local stresses in connections using multiple fasteners can be evaluated in accordance with NDS Appendix E.

94 84 M12: DOWEL-TYPE FASTENERS

95 MANUAL FOR ENGINEERED WOOD CONSTRUCTION 85 M13: SPLIT RING AND SHEAR PLATE CONNECTORS M13.1 General 86 M13.2 Reference Design Values 86 M13.3 Placement of Split Ring and Shear Plate Connectors 86 13

96 86 M13: SPLIT RING AND SHEAR PLATE CONNECTORS M13.1 General This Chapter covers design for split rings and shear plates. These connectors rely on their geometry to provide larger metal-to-wood bearing areas per connector. Both are installed into precut grooves or daps in the members. M13.2 Reference Design Values Reference lateral design values (P, Q) are tabulated in the split ring and shear plate tables in NDS Design Adjustment Factors Split ring and shear plate connections must be designed by applying all applicable adjustment factors to the reference lateral design value for the connection. NDS Table provides all applicable adjustment factors for split ring and shear plate connectors. Table M shows the applicability of adjustment factors for dowel-type fasteners in a slightly different format for the designer. Table M Applicability of Adjustment Factors for Split Ring and Shear Plate Connectors 1 Split Ring and Shear Plate Connectors Allowable Stress Design Load and Resistance Factor Design P = P C D C M C t C g C C d C st P = P C M C t C g C C d C st (3.32)(0.65) λ Q = Q C D C M C t C g C C d Q = Q C M C t C g C C d (3.32)(0.65) λ 1. See NDS Table footnotes for additional guidance on application of adjustment factors for split ring and shear plate connectors. For a single split ring or shear plate connection installed in side grain perpendicular to the length of the wood members, meeting the end and edge distance and spacing requirements of NDS 13.3, used in a normal building environment (meeting the reference conditions of NDS 2.3 and 11.3), and meeting the penetration requirements of NDS , the general equations for P and Q reduce to: for ASD: P = P C D Q = Q C D for LRFD: P = P (3.32)(0.65) λ Q = Q (3.32)(0.65) λ M13.3 Placement of Split Ring and Shear Plate Connectors Installation Requirements To achieve stated design values, connectors must comply with installation requirements such as spacing of connectors, minimum edge and end distances, proper dapping and grooving, drilling of lead holes, and minimum fastener penetration as specified in NDS 13.3.

97 MANUAL FOR ENGINEERED WOOD CONSTRUCTION 87 M14: TIMBER RIVETS M14.1 General 88 M14.2 Reference Design Values 88 M14.3 Placement of Timber Rivets 88 14

98 88 M14: TIMBER RIVETS M14.1 General This Chapter covers design for timber rivets. Timber rivets are hardened steel nails that are driven through predrilled holes in steel side plates (typically 1/4" thickness) to form an integrated connection where the plate and rivets work together to transfer load to the wood member. M14.2 Reference Design Values Reference wood capacity design values parallel to grain, P w, are tabulated in the timber rivet Tables A through F in the NDS. Reference design values perpendicular to grain are calculated per NDS Design Adjustment Factors Connections must be designed by applying all applicable adjustment factors to the reference lateral design value for the connection. NDS Table lists all applicable adjustment factors for timber rivets. Table M shows the applicability of adjustment factors for timber rivets in a slightly different format for the designer. Table M Applicability of Adjustment Factors for Timber Rivets 1 Timber Rivets Allowable Stress Design Load and Resistance Factor Design P = P C D C M C t C st P = P C M C t C st (3.32)(0.65) λ Q = Q C D C M C t C D C st Q = Q C M C t C D C st (3.32)(0.65) λ 1. See NDS Table footnotes for additional guidance on application of adjustment factors for timber rivets. For a timber rivet connection installed in side grain perpendicular to the length of the wood members, with metal side plates 1/4" or greater, used in a normal building environment (meeting the reference conditions of NDS 2.3 and 11.3), and where wood capacity perpendicular to grain, Q w, does not control, the general equations for P and Q reduce to: for ASD: P = P C D Q = Q C D for LRFD: P = P (3.32)(0.65) λ Q = Q (3.32)(0.65) λ M14.3 Placement of Timber Rivets Installation Requirements To achieve stated design values, connectors must comply with installation requirements such as spacing of connectors, minimum edge and end distances per NDS 14.3; and drilling of lead holes, minimum fastener penetration, and other fabrication requirements per NDS

99 MANUAL FOR ENGINEERED WOOD CONSTRUCTION 89 M15: SPECIAL LOADING CONDITIONS M15.1 Lateral Distribution of Concentrated Loads 90 M Lateral Distribution of a Concentrated Load for Moment 90 M Lateral Distribution of a Concentrated Load for Shear 90 M15.2 Spaced Columns 90 M15.3 Built-Up Columns 90 M15.4 Wood Columns with Side Loads and Eccentricity 90 15

100 90 M15: SPECIAL LOADING CONDITIONS M15.1 Lateral Distribution of Concentrated Loads M Lateral Distribution of a Concentrated Load for Moment The lateral distribution factors for moment in NDS Table are keyed to the nominal thickness of the flooring or decking involved (2" to 6" thick). Spacing of the stringers or beams is based on recommendations of the American Association of State Highway and Transportation Officials. Lateral distribution factors determined in accordance with NDS Table can be used for any type of fixed or moving concentrated load. M Lateral Distribution of a Concentrated Load for Shear The lateral distribution factors for shear in NDS Table relate the lateral distribution of concentrated load at the center of the beam or stringer span as determined under NDS , or by other means, to the distribution of load at the quarter points of the span. The quarter points are considered to be near the points of maximum shear in the stringers for timber bridge design. M15.2 Spaced Columns As used in the NDS, spaced columns refer to two or more individual members oriented with their longitudinal axis parallel, separated at the ends and in the middle portion of their length by blocking and joined at the ends by split ring or shear plate connectors capable of developing required shear resistance. The end fixity developed by the connectors and end blocks increases the load-carrying capacity in compression parallel to grain of the individual members only in the direction perpendicular to their wide faces. AWC s Wood Structural Design Data (WSDD) provides load tables for spaced columns. M15.3 Built-Up Columns As with spaced columns, built-up columns obtain their efficiency by increasing the buckling resistance of individual laminations. The closer the laminations of a mechanically fastened built-up column deform together (the smaller the amount of slip occurring between laminations) under compressive load, the greater the relative capacity of that column compared to a simple solid column of the same slenderness ratio made with the same quality of material. M15.4 Wood Columns with Side Loads and Eccentricity The eccentric load design provisions of NDS are not generally applied to columns supporting beam loads where the end of the beam bears on the entire cross section of the column. It is standard practice to consider such loads to be concentrically applied to the supporting column. This practice reflects the fact that the end fixity provided by the end of the column is ignored when the usual pinned end condition is assumed in column design. In applications where the end of the beam does not bear on the full cross section of the supporting column, or in special critical loading cases, use of the eccentric column loading provisions of NDS may be considered appropriate by the designer.

101 MANUAL FOR ENGINEERED WOOD CONSTRUCTION 91 M16: FIRE DESIGN M16.1 General 92 Lumber 94 Structural Glued Laminated Timber 94 Poles and Piles 95 Structural Composite Lumber 95 Wood I-Joists 96 Metal Plate Connected Wood Trusses 96 Transitory Floor Vibration and Sound Transmission 99 M16.2 Design Procedures for Exposed Wood Members 100 M16.3 Wood Connections

102 92 M16: FIRE DESIGN M16.1 General This Chapter outlines fire considerations including design requirements and fire-rated assemblies for various wood products. Lumber, glued laminated timber, poles and piles, wood I-joists, structural composite lumber, metal plate connected wood trusses, and cross-laminated timber are discussed. Planning As a first step, the authority having jurisdiction where a proposed building is to be constructed must be consulted for the requirements of the specific design project. This normally concerns the type of construction desired as well as allowable building areas and heights for each construction type. Wood building construction is generally classified into types such as wood frame (Type V), noncombustible or fire-retardant-treated wood wall-wood joist (Type III), and heavy timber (Type IV). Type V construction is defined as having exterior walls, bearing walls, partitions, floors and roofs of wood stud and joist framing of 2" nominal dimension. These are divided into two subclasses that are either protected or unprotected construction. Protected construction calls for having load bearing assemblies of 1 hour fire endurance. Type III construction has exterior walls of noncombustible materials and roofs, floors, and interior walls and partitions of wood frame. As in Type V construction, these are divided into two subclasses that are either protected or unprotected. Type IV construction includes exterior walls of noncombustible materials or fire-retardant-treated wood and columns, floors, roofs, and interior partitions of wood of a minimum size, as shown in Tables M and M In addition to having protected and unprotected subclasses for each building type, increases in floor area and height of the building are allowed when active fire protection, such as sprinkler protection systems, are included. For example, protected wood-frame business occupancies can be increased from three to four stories in height because of the presence of sprinklers. Also, the floor area may be further increased under some conditions. Additional information is available at Table M Heavy Timber Size Equalivalencies Minimum Nominal Solid Sawn Size Minimum Glued Laminated Timber Net Size Minimum Structural Composite Lumber Net Size Width, inch Depth, inch Width, inch Depth, inch Width, inch Depth, inch /4 8-1/ / /2 5-1/4 9-1/ /4 5-1/4 7-1/ /4 5-1/ /8 3-1/2 5-1/2

103 MANUAL FOR ENGINEERED WOOD CONSTRUCTION 93 Table M Minimum Sizes to Qualify as Heavy Timber Construction Material Roof Decking Floor Decking Roof Framing Floor Framing Columns Exterior Walls Minimum Size (all sizes nominal unless noted) Sawn or glued laminated lumber planks, splined or T&G 2 in. thickness Structural-use panels 1-1/8 in. thickness 1 Planks set on edge close together 3 in. width Cross-laminated timber 3 in. thickness (actual) Sawn or glued laminated lumber planks, splined or T&G, and 3 in. thickness topped with - Tongue-and-groove flooring, or 1 in. thickness 1 - Wood Structural panel, or 15/32 in. thickness 1 - Particleboard 1/2 in. thickness Planks set on edge close together, and topped with 4 in. width - Flooring, or 1 in. thickness 1 - Wood Structural panel, or 15/32 in. thickness 1 - Particleboard 1/2 in. thickness Cross-laminated timber 4 in. thickness (actual) Wood-frame or glued laminated arches from the floor line or grade not supporting floors - Lower half of the height 6 in. width by 8 in. width - Upper half of the height 6 in. width by 6 in. width Wood-frame or glued laminated arches from the top of walls, not 4 in. width by 6 in. width supporting floors Framed timber trusses and other roof framing 4 in. width by 6 in. width Spaced members shall be permitted to be composed of two or more 3 in. thickness pieces where - Blocked solidly throughout the intervening spaces 2 in, thickness - Spaces are tightly closed by a continuous wood cover plate secured 2 in. thickness to the underside of the members - Splice plates 3 in. thickness Roof framing members protected by approved automatic sprinklers 3 in. width under the roof deck Sawn or glued-laminated beams and girders 6 in. width by 10 in. depth Wood-frame or glulam arches from the floor line or grade supporting floors 8 in. width by 8 in. depth Framed timber trusses 8 in. width by 8 in. depth Sawn or glued-laminated beams and girders - Supporting floor loads 8 in. width by 8 in. depth - Supporting only roof and ceiling loads 6 in. width by 8 in. depth Cross-laminated timber with fire-resistance rating up to 2 hours and covered with 6 in. total wall thickness (actual) - Fire-retardant-treated wood sheathing, or 15/32 in. thickness 1 - Gypsum board 1/2 in. thickness 1. Performance Category value for wood structural panels produced in accordance with PS 1 or PS 2. M16: FIRE DESIGN 16

104 94 M16: FIRE DESIGN Lumber Building Code Requirements For occupancies such as stores, apartments, offices, and other commercial and industrial uses, building codes commonly require floor/ceiling and wall assemblies to be fire-resistance rated in accordance with standard fire tests. Depending on the application, wall assemblies may need to be rated either from one side or both sides. For specific exterior wall applications, the International Building Code (IBC) allows wood-frame, wood-sided walls to be tested for exposure to fire from the inside only. Rating for both interior and exterior exposure is only required when the wall has a fire separation distance of less than 5 feet. Code recognition of 1- and 2-hour wood-frame wall systems is also predicated on successful fire and hose stream testing in accordance with ASTM E119, Standard Test Methods for Fire Tests of Building Construction Materials. Fire Tested Assemblies Fire-rated wood-frame assemblies can be found in a number of sources including the IBC, Underwriters Laboratories (UL) Fire Resistance Directory, Intertek Testing Services Directory of Listed Products, and the Gypsum Association s Fire Resistance Design Manual. The American Wood Council (AWC) and its members have tested a number of wood-frame fire-rated assemblies. Descriptions of these successfully tested assemblies are provided in AWC s Design for Code Acceptance (DCA) No. 3, Fire Rated Wood Floor and Wall Assemblies which is available at Structural Glued Laminated Timber Fires do not normally start in structural framing, but rather in the building s contents. These fires generally reach temperatures of between 1,290 F and 1,650 F. Glued laminated timber members perform very well under these conditions. Unprotected steel members typically suffer severe buckling and twisting during fires, often collapsing catastrophically. Wood ignites at about 480 F, but charring may begin as low as 300 F. Wood typically chars at 1/40 in. per minute. Thus, after 30 minutes of fire exposure, only the outer 3/4 in. of the structural glued laminated timber will be damaged. Char insulates a wood member and hence raises the temperature it can withstand. Most of the cross section will remain intact, and the member will continue supporting loads during a typical building fire. It is important to note that neither building materials alone, nor building features alone, nor detection and fire extinguishing equipment alone can provide adequate safety from fire in buildings. To ensure a safe structure in the event of fire, authorities base fire and building code requirements on research and testing, as well as fire histories. The model building codes classify heavy timber as a specific type of construction and give minimum sizes for roof and floor beams. The requirements set out for heavy timber construction in model building codes do not constitute 1-hour fire resistance. However, procedures are available to calculate the structural glued laminated timber size required for projects in which 1-hour fire resistance is required (see NDS 16.2 and AWC s Technical Report 10 available at To achieve a 1-hour fire rating for beams whose dimensions qualify them for this rating, the basic layup must be modified one core lamination must be removed from the center and the tension face augmented with the addition of a tension lamination. For more information concerning the effects of fire on structural glued laminated timber, refer to APA EWS Technical Note Y245 or AITC Technical Note 7. For determining fire resistance other than 1 hour, see NDS 16.2 and AWC s Technical Report 10 available at

105 MANUAL FOR ENGINEERED WOOD CONSTRUCTION 95 Poles and Piles Very few elements of modern structures can be called fire proof. Even in buildings where the major structural members are noncombustible, most of the furnishings are flammable. It is for this reason that much of the attention in modern building codes addresses issues related to containing and limiting fires, rather than simply calling materials combustible and noncombustible. While this topic is fairly complex for other types of products, fire performance is relatively straightforward for poles and piles. Poles are generally used in cross-sectional sizes that qualify as heavy timber construction in the model building codes. On this basis, timber poles compare favorably with other construction materials in their performance under fire conditions. Piles are generally not exposed to fire conditions unless they extend substantially above the groundline. Structural Composite Lumber Engineered wood products have fire resistive characteristics very similar to conventional wood frame members. Since many engineered wood products are proprietary, they are usually recognized in a code evaluation report published by an evaluation service. Each evaluation report usually contains fire resistance information. Very few elements of modern structures can be called fire proof. Even in buildings where the major structural members are noncombustible, most of the furnishings are flammable. It is for this reason that much of the attention in model building codes addresses issues related to containing and limiting fires, rather than simply calling materials combustible and noncombustible. The primary intent of the building codes is to ensure structural stability to allow exiting, evacuation, and fire fighting. As with the previous topic of durability, this Manual cannot cover the topic of designing for optimal structural performance in fire conditions in detail. There are many excellent texts on the topic, and designers are advised to use this information early in the design process. To assist the designer in understanding several ways in which fire performance can be addressed, the following overview is provided. Fire sprinklers are probably the most effective method to enhance fire resistance of engineered wood systems (as well as other systems). They are designed to control the fire while protecting the occupants and the building until the fire department arrives. They are the ultimate way to improve fire safety. Heavy timber construction has proven to be acceptable in many areas where fire safety is of utmost concern. These applications have proven to be not only reliable, but economical in certain structures many wider width SCL products can be used in heavy timber construction. Consult manufacturer s literature or code evaluation reports for specific information. The fire performance of wood structures can be enhanced in the same ways as that of structures of steel, concrete, or masonry: Fire sprinkler systems have proven to be effective in a variety of structures, both large and small Protection of the structural members with materials such as properly attached gypsum sheathing can provide greatly improved fire performance. Fire ratings, as established from test procedures specified in ASTM E-119, of up to 2 hours can be achieved through the use of gypsum sheathing Where surface burning characteristics are critical, fire-retardant treatments can be used to reduce the flamespread for some products To reiterate, this Manual does not purport to address this topic in an all-inclusive manner it is merely an attempt to alert designers to the need to address fire performance issues in the design of the structure. M16: FIRE DESIGN 16

106 96 M16: FIRE DESIGN Wood I-Joists The wood I-joist industry has actively supported the following projects to establish fire performance of systems using wood I-joist products: ASTM E-119 fire tests have been conducted by the wood I-joist industry to establish fire resistance ratings for generic I-joist systems. Detailed descriptions of these systems are shown in AWC s Design for Code Acceptance (DCA) No. 3, Fire Rated Wood Floor and Wall Assemblies available at org. ASTM E-119 fire tests have been conducted by wood I-joist manufacturers to establish fire resistance ratings for proprietary I-joist systems. Detailed descriptions of these systems are available from the individual I joist manufacturer. National Fire Protection Research Foundation Report titled National Engineered Lightweight Construction Fire Research Project. This report documents an extensive literature search of the fire performance of engineered lightweight construction. A video, I-JOISTS:FACTS ABOUT PROGRESS, has been produced by the Wood I-Joist Manufacturer s Association (WIJMA). This video describes some basic facts about changes taking place within the construction industry and the fire service. Along with this video is a document that provides greater details on fire performance issues. Industry research in fire endurance modeling for I-joist systems. Metal Plate Connected Wood Trusses Generally, a fire endurance rating of 1 hour is mandated by code for many of the applications where trusses could be used. All testing on these assemblies is performed in accordance with the ASTM s Standard Methods for Fire Tests of Building Construction and Materials (ASTM E119). The two primary source documents for fire endurance assembly results are the Fire Resistance Design Manual, published by the Gypsum Association (GA), and the Fire Resistance Directory, published by Underwriters Laboratories, Inc. (UL). Warnock Hersey (WH) assemblies are now listed in the ITS Directory of Listed Products. These tested assemblies are available for specification by architects or building designers, and for use by all truss manufacturers where a rated assembly is required, and can generally be applied to both floor and roof assembly applications. According to the UL Directory s Design Information Section: Ratings shown on individual designs apply to equal or greater height or thickness of the assembly, and to larger structural members, when both size and weight are equal or larger than specified, and when the thickness of the flanges, web or diameter of chords is equal or greater. Thus, larger and deeper trusses can be used under the auspices of the same design number. This approach has often been used in roof truss applications since roof trusses are usually much deeper than the tested assemblies. Thermal and/or acoustical considerations at times may require the installation of insulation in a floor-ceiling or roof-ceiling assembly that has been tested without insulation. As a general rule, experience indicates that it is allowable to add insulation to an assembly, provided that the depth of the truss is increased by the depth of the insulation. And as a general rule, assemblies that were tested with insulation may have the insulation removed. To make a rational assessment of any modification to a tested assembly, one must look at the properties of the insulation and the impact that its placement inside the assembly will have on the fire endurance performance of the assembly. Insulation retards the transfer of heat, is used to retain heat in warm places, and reduces the flow of heat into colder areas. As a result, its addition to a fire endurance assembly will affect the flow of heat through and within an assembly. One potential effect of insulation placed directly on the gypsum board is to retard the dissipation of heat through the assembly, concentrating heat in the protective gypsum board. In some cases specific branded products are listed in the test specifications. Modifications or substitutions to fire endurance assemblies should be reviewed with the building designer and code official, preferably with the assistance of a professional engineer. This review is required because the final performance of the assembly is a result of the composite of the materials used in the construction of the assembly. The Structural Building Components Association provides summaries of wood truss fire endurance assemblies and sound transmission ratings. For more information, visit

107 MANUAL FOR ENGINEERED WOOD CONSTRUCTION 97 Also, several truss plate manufacturers have developed proprietary fire resistant assemblies. These results apply only to the specific manufacturer s truss plates and referenced fire endurance assembly system. For more detailed information on these assemblies, the individual truss plate manufacturer should be contacted. Complete specifications on the UL, GA, and WH assemblies are available on their respective websites. Area Separation Assemblies It is of great concern when fire-rated assemblies are designed and specified without consideration of sound structural principles. Should a fire develop, these structural inadequacies could cause the assemblies to fail unexpectedly, increasing the risk of loss of life. There are a number of ways to provide sound structural and fire endurance details that maintain 1-hour rated area separation assemblies. Figure M shows several possible assemblies that can be used to make up the 1-hour rated system for separation between occupancies for a) floor trusses parallel to the wall assembly; and b) perpendicular to the wall assembly. A 2x4 firestop is used between the walls next to the wall top plates. This effectively prevents the spread of fire inside the wall cavity. A minimum 1/2-inch gypsum wallboard attached to one side of the floor truss system, and located between the floor trusses, also provides a draftstop and fire protection barrier between occupancy spaces if a fire starts in the floor truss concealed space, which is a rare occurrence. The tenant separation in the roof is maintained through the use of a 1/2-inch gypsum wallboard draftstop attached to the ends of one side of the monopitch trusses and provided for the full truss height. Figure M effectively provides 1-hour compart mentation for all the occupied spaces using listed 1-hour rated assemblies and the appropriate draftstops for the concealed spaces as prescribed by the model building codes. If a fire-resistive assembly, rather than draftstopping, is required within concealed attic spaces, UL U338, U339, and U377, provide approved 1-hour and 2-hour rated assemblies that may be used within the roof cavity and that may be constructed with gable end frames. The critical aspects for fire endurance assemblies include: Ensuring that the wall and ceiling assemblies of the room use 1-hour rated assemblies. These are independent assemblies. The wall assembly does not have to be continuous from the floor to the roof to meet the intent of the code or the fire endurance performance of the structure. The intent of the code is that the building be broken into compartments to contain a fire to a given area. Fire resistance assemblies are tested to provide code-complying fire endurance to meet the intent of the code. The foregoing details meet the intent of the code. Properly fastening the gypsum wallboard to the wall studs and trusses. This is critical for achieving the desired fire performance from a UL or GA assembly. Ensuring that the detail being used is structurally sound, particularly the bearing details. All connection details are critical to assembly performance. When a fire begins, if the structural detail is poor, the system will fail at the poor connection detail earlier than expected. Accommodating both sound structural details with appropriate fire endurance details. Since all conceivable field conditions have not been and cannot be tested, rational engineering judgment needs to be used. The foregoing principles could also be applied to structures requiring 2-hour rated area separation assemblies. In this case, acceptable 2-hour wall assemblies would be used in conjunction with the 2-hour floor-ceiling and roof-ceiling fire endurance assemblies. Through-Penetration Fire Stops Because walls and floors are penetrated for a variety of plumbing, ventilation, electrical, and communication purposes, ASTM E814 Standard Method of Fire Tests of Through-Penetration Fire Stops uses fire-resistive assemblies (rated per ASTM E119) and penetrates them with cables, pipes, and ducts, etc., before subjecting the assembly to ASTM E119 s fire endurance tests. Despite the penetrations, firestop assemblies tested according to ASTM E814 must not significantly lose their fire containment properties in order to be considered acceptable. Properties are measured according to the passage of any heat, flame, hot gases, or combustion through the fire stop to the test assembly s unexposed surface. Upon successful completion of fire endurance tests, fire stop systems are given F&T ratings. These ratings are expressed in hourly terms, in much the same fashion as fire-resistive barriers. To obtain an F-Rating, a fire stop must remain in the opening during the fire and hose stream test, withstanding the fire test for a prescribed rating period without permitting the passage of flame on any element of its unexposed side. During the hose stream test, a fire stop must not develop any opening that would permit a projection of water from the stream beyond the unexposed side. To obtain a T-Rating, a fire stop must meet the requirements of the F-Rating. In addition, the fire stop must prevent the transmission of heat during the prescribed rating period which would increase the temperature of any M16: FIRE DESIGN 16

108 98 M16: FIRE DESIGN Figure M Cross Sections of Possible One-Hour Area Separations

109 MANUAL FOR ENGINEERED WOOD CONSTRUCTION 99 thermocouple on its unexposed surface, or any penetrating items, by more than 325 F. The UL Fire Resistance Directory lists literally thousands of tested systems. They have organized the systems with an alpha-alpha-numeric identification number. The first alpha is either a F, W, or C. These letters signify the type of assembly being penetrated: F signifies a floor, W signifies a wall, and C signifies a ceiling. The second alpha signifies a limiting description, for example: C signifies a framed floor, and L signifies a framed wall. The numeric portion is also significant: signifies no penetrating items, signifies metallic pipe, signifies nonmetallic pipe, signifies electrical cable, signifies cable trays, signifies insulated pipes, signifies miscellaneous electrical penetrants, signifies miscellaneous mechanical penetrants, and signifies a combination of penetrants. Transitory Floor Vibration and Sound Transmission Sound Transmission Sound transmission ratings are closely aligned with fire endurance ratings for assemblies. This is due to the fact that flame and sound penetrations follow similar paths of least resistance. Sound striking a wall or ceiling surface is transmitted through the air in the wall or ceiling cavity. It then strikes the opposite wall surface, causing it to vibrate and transmit the sound into the adjoining room. Sound also is transmitted through any openings into the room, such as air ducts, electrical outlets, window openings, and doors. This is airborne sound transmission. The Sound Transmission Class (STC) method of rating airborne sounds evaluates the comfort ability of a particular living space. The higher the STC, the better the airborne noise control performance of the structure. An STC of 50 or above is generally considered a good airborne noise control rating. Table M describes the privacy afforded according to the STC rating. Impact Sound Transmission is produced when a structural element is set into vibration by direct impact someone walking, for example. The vibrating surface generates sound waves on both sides of the element. The Impact Insulation Class (IIC) is a method of rating the impact sound transmission performance of an assembly. The higher the IIC, the better the impact noise control of the element. An IIC of 55 is generally considered a good impact noise control. Table M Privacy Afforded According to STC Rating STC Rating Privacy Afforded 25 Normal speech easily understood 30 Normal speech audible, but not intelligible 35 Loud speech audible and fairly understandable 40 Loud speech barely audible, but not intelligible 45 Loud speech barely audible 50 Shouting barely audible 55 Shouting inaudible M16: FIRE DESIGN 16

110 100 M16: FIRE DESIGN M16.2 Design Procedures for Exposed Wood Members For members stressed in one principle direction, simplifications can be made which allow the tabulation of load factor tables for fire design. These load factor tables can be used to determine the structural design load ratio, R s, at which the member has sufficient capacity for a given fire endurance time. AWC s Technical Report 10 Calculating the Fire Resistance of Exposed Wood Members provides derivation of load ratios and load ratio tables for bending, compression, and tension members. TR10 is available at

111 MANUAL FOR ENGINEERED WOOD CONSTRUCTION 101 M16.3 Wood Connections Where 1-hour fire endurance is required, connectors and fasteners must be protected from fire exposure by 1.5" of wood, fire-rated gypsum board, or any coating approved for a 1-hour rating. Typical details for commonly used fasteners and connectors in timber framing are shown in Figure M through Figure M Figure M Beam to Column Connection - Connection Exposed to Fire Where Appearance is Not a Factor Provide lateral support for end of beam Figure M Beam to Column Connection - Connection Not Exposed to Fire Provide lateral support for end of beam Wood beam Steel connec on welded to steel plate cast-in top of concrete column Exposed por on of beam Apply approved fire protec ve coa ng rated for required fire-resistance ra ng over steel 2x backup nailer to box-in around beam Concrete column Gypsum board layer(s) having finish ra ng the required fire-resistance ra ng ELEVATION ELEVATION Figure M Beam to Column Connection - Connection Exposed to Fire Where Appearance is a Factor Provide lateral support for end of beam Wood plug over bolt, having depth a char /1.2 Cross shaped connec on recessed in wood Wood beam Fill void around seat with plaster of paris or approved compount Wood column M16: FIRE DESIGN 16 END VIEW ELEVATION

112 102 M16: FIRE DESIGN Figure M Column Connections Covered Provide lateral support for end of beams Figure M Beam to Girder - Concealed Connection Top surfaces of beam and girder protected by floor/roof (not shown) Wood beam Standard steel connec ons box-in using wood members with thickness a char /1.2 to protect steel Wood column TOP VIEW Wood plug over bolt, having depth a char /1.2 ELEVATION Wood cover a char /1.2 on bo om and sides Floor ELEVATION

113 American Wood Council AWC Mission Statement To increase the use of wood by assuring the broad regulatory acceptance of wood products, developing design tools and guidelines for wood construction, and influencing the development of public policies affecting the use and manufacture of wood products.

114 ISBN American Wood Council 222 Catoctin Circle, SE, Suite 201 Leesburg, VA

2005 EDITION ASD/LRFD MANUAL MANUAL FOR ENGINEERED WOOD CONSTRUCTION. American Forest & Paper Association. American Wood Council

2005 EDITION ASD/LRFD MANUAL MANUAL FOR ENGINEERED WOOD CONSTRUCTION. American Forest & Paper Association. American Wood Council 2005 EDITION ASD/LRFD MANUAL MANUAL FOR ENGINEERED WOOD CONSTRUCTION American Forest & Paper Association American Wood Council Updates and Errata While every precaution has been taken to ensure the accuracy

More information

2005 EDITION ASD/LRFD MANUAL MANUAL FOR ENGINEERED WOOD CONSTRUCTION. American Forest & Paper Association. American Wood Council

2005 EDITION ASD/LRFD MANUAL MANUAL FOR ENGINEERED WOOD CONSTRUCTION. American Forest & Paper Association. American Wood Council 2005 EDITION ASD/LRFD MANUAL MANUAL FOR ENGINEERED WOOD CONSTRUCTION American Forest & Paper Association American Wood Council May 2013 Codes and Standards Addenda and Amendments Related to Design Value

More information

CH. 9 WOOD CONSTRUCTION

CH. 9 WOOD CONSTRUCTION CH. 9 WOOD CONSTRUCTION PROPERTIES OF STRUCTURAL LUMBER Grading Load carrying capacity effected by: - Size and number of knots, splits & other defects - Direction of grain - Specific gravity of wood Grading

More information

2005 ERRATA to the Edition of. the Allowable Stress Design (ASD) Manual for Engineered Wood Construction (printed version dated M)

2005 ERRATA to the Edition of. the Allowable Stress Design (ASD) Manual for Engineered Wood Construction (printed version dated M) AMERICAN FOREST & PAPER ASSOCIATION American Wood Council Engineered and Traditional Wood Products June 2005 2005 ERRATA the Allowable Stress Design (ASD) Manual for Engineered Wood Construction 93 In

More information

National Design Specification for Wood Construction. Copyright Materials. Learning Objectives

National Design Specification for Wood Construction. Copyright Materials. Learning Objectives National Design Specification for Wood Construction The Wood Products Council is a Registered Provider with The American Institute of Architects Continuing Education Systems (AIA/CES). Credit(s) earned

More information

John Buddy Showalter, PE Vice President, Technology Transfer American Wood Council

John Buddy Showalter, PE Vice President, Technology Transfer American Wood Council 2015 NDS Changes John Buddy Showalter, PE Vice President, Technology Transfer American Wood Council Michelle Kam-Biron, PE, SE, SECB Director of Education American Wood Council Copyright Materials This

More information

The listed reference design values are for visually graded dimension lumber 2-4 inches thick

The listed reference design values are for visually graded dimension lumber 2-4 inches thick The listed reference design values are for visually graded dimension lumber 2-4 inches thick Species/ grade Bending Tension parallel Design values in pounds per square inch (psi) Shear Compression Compression

More information

twelve wood construction: materials & beams ARCHITECTURAL STRUCTURES: FORM, BEHAVIOR, AND DESIGN DR. ANNE NICHOLS SUMMER 2014 lecture

twelve wood construction: materials & beams ARCHITECTURAL STRUCTURES: FORM, BEHAVIOR, AND DESIGN DR. ANNE NICHOLS SUMMER 2014 lecture ARCHITECTURAL STRUCTURES: FORM, BEHAVIOR, AND DESIGN DR. ANNE NICHOLS SUMMER 2014 lecture twelve wood construction: materials & beams Wood Beams 1 Wood Beam Design National Design Specification National

More information

thirteen wood construction: materials & beams ELEMENTS OF ARCHITECTURAL STRUCTURES: FORM, BEHAVIOR, AND DESIGN DR. ANNE NICHOLS SPRING 2016 lecture

thirteen wood construction: materials & beams ELEMENTS OF ARCHITECTURAL STRUCTURES: FORM, BEHAVIOR, AND DESIGN DR. ANNE NICHOLS SPRING 2016 lecture ELEMENTS OF ARCHITECTURAL STRUCTURES: FORM, BEHAVIOR, AND DESIGN DR. ANNE NICHOLS SPRING 2016 lecture thirteen wood construction: materials & beams Wood Beams 1 Wood Beam Design National Design Specification

More information

Significant Changes to AWC s Special Design Provisions for Wind and Seismic

Significant Changes to AWC s Special Design Provisions for Wind and Seismic Significant Changes to AWC s Special Design Provisions for Wind and Seismic Michelle Kam-Biron, PE, SE, SECB Director of Education American Wood Council Copyright Materials This presentation is protected

More information

thirteen wood construction: materials & beams Timber Wood Beam Design Wood Properties

thirteen wood construction: materials & beams Timber Wood Beam Design Wood Properties ELEMENTS OF ARCHITECTURAL STRUCTURES: FORM, BEHAVIOR, AND DESIGN DR. ANNE NICHOLS SPRING 2018 lecture thirteen wood construction: materials & beams Wood Beams 1 Wood National Design Specification f Wood

More information

twelve wood construction: materials & beams Wood Beam Design Wood Properties Timber National Design Specification

twelve wood construction: materials & beams Wood Beam Design Wood Properties Timber National Design Specification ARCHITECTURAL STRUCTURES: FORM, BEHAVIOR, AND DESIGN DR. ANNE NICHOLS SUMMER 2017 lecture twelve wood construction: materials & beams Wood Beams 1 Lecture 12 Architectural Structures F2009abn Wood Beam

More information

twelve wood construction: materials & beams Wood Beam Design Wood Properties Timber National Design Specification

twelve wood construction: materials & beams Wood Beam Design Wood Properties Timber National Design Specification ARCHITECTURAL STRUCTURES: FORM, BEHAVIOR, AND DESIGN DR. ANNE NICHOLS SUMMER 2016 lecture twelve wood construction: materials & beams Wood Beams 1 Lecture 12 Architectural Structures F2009abn Wood Beam

More information

twelve wood construction: materials & beams Wood Beam Design Timber Wood Properties National Design Specification

twelve wood construction: materials & beams Wood Beam Design Timber Wood Properties National Design Specification ARCHITECTURAL STRUCTURES: FORM, BEHAVIOR, AND DESIGN DR. ANNE NICHOLS SUMMER 20178 lecture twelve wood construction: materials & beams Wood Beams 1 Lecture 12 Architectural Structures F2009abn Wood National

More information

twelve wood construction: materials & beams Wood Beam Design Wood Properties Timber National Design Specification

twelve wood construction: materials & beams Wood Beam Design Wood Properties Timber National Design Specification ARCHITECTURAL STRUCTURES: FORM, BEHAVIOR, AND DESIGN DR. ANNE NICHOLS SUMMER 2014 lecture twelve wood construction: materials & beams Wood Beams 1 Lecture 12 Architectural Structures F2009abn Wood Beam

More information

IAPMO UNIFORM EVALUATION SERVICES EVALUATION CRITERIA FOR JOIST HANGERS AND MISCELLANEOUS CONNECTORS

IAPMO UNIFORM EVALUATION SERVICES EVALUATION CRITERIA FOR JOIST HANGERS AND MISCELLANEOUS CONNECTORS IAPMO UNIFORM EVALUATION SERVICES EVALUATION CRITERIA FOR JOIST HANGERS AND MISCELLANEOUS CONNECTORS EC 002-2017 (Adopted June 2007, Revised August 2017) 1.0 INTRODUCTION 1.1 Purpose: The purpose of this

More information

Joint Evaluation Report

Joint Evaluation Report 0 Joint Evaluation Report ICC ES (800) 423 6587 (562) 699 0543 www.icc es.org 000 ESR 1040 Reissued 09/2018 Revised 03/2019 This report is subject to renewal 09/2019. DIVISION: 06 00 00 WOOD, PLASTICS

More information

Joint Evaluation Report

Joint Evaluation Report 0 Joint Evaluation Report ICC-ES (800) 423-6587 (562) 699-0543 www.icc-es.org 000 ESR-1040 Reissued 09/2016 This report is subject to renewal 09/2018. DIVISION: 06 00 00 WOOD, PLASTICS AND COMPOSITES SECTION:

More information

Joint Evaluation Report

Joint Evaluation Report 0 Joint Evaluation Report ICC-ES (800) 423-6587 (562) 699-0543 www.icc-es.org 000 ESR-1040 Reissued 09/2018 This report is subject to renewal 09/2019. DIVISION: 06 00 00 WOOD, PLASTICS AND COMPOSITES SECTION:

More information

Method for Increased Buckling Capacity of Built-Up Beams and Columns

Method for Increased Buckling Capacity of Built-Up Beams and Columns Method for Increased Buckling Capacity of Built-Up Beams and Columns Donald A. Bender, Robert E. Kimble, and Frank E. Woeste Abstract Built-up beams and columns made of dimension lumber fastened with nails,

More information

Determining Allowable Design Values for Wood

Determining Allowable Design Values for Wood PDHonline ourse S246 (3 PDH) Determining Allowable Design Values for Wood Instructor: Richard E. Nolan, PE 2012 PDH Online PDH enter 5272 Meadow Estates Drive Fairfax, VA 22030-6658 Phone & Fax: 703-988-0088

More information

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: LAMINATED VENEER LUMBER REPORT HOLDER: REDBUILT LLC EVALUATION SUBJECT:

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: LAMINATED VENEER LUMBER REPORT HOLDER: REDBUILT LLC EVALUATION SUBJECT: 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 42 6587 (562) 699 054 www.icc es.org ESR 299 Reissued 01/2019 This report is subject to renewal 01/2021. DIVISION: 06 00 00

More information

Changes to the 2005 NDS Supplement Design Values for Wood Construction

Changes to the 2005 NDS Supplement Design Values for Wood Construction Changes to the 2005 NDS Supplement Design Values for Wood Construction by Kevin Cheung, Jeff Linville, Phil Line Introduction An integral part of the National Design Specification (NDS ) for Wood Construction

More information

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: SHOP FABRICATED WOOD TRUSSES REPORT HOLDER: BARRETTE STRUCTURAL DISTRIBUTION, INC.

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: SHOP FABRICATED WOOD TRUSSES REPORT HOLDER: BARRETTE STRUCTURAL DISTRIBUTION, INC. 0 Most Widely Accepted and Trusted ICC ES Report ICC ES 000 (800) 43 6587 (56) 699 0543 www.icc es.org ESR 999 Reissued 0/07 This report is subject to renewal 0/08. DIVISION: 06 00 00 WOOD, PLASTICS AND

More information

AITC TECHNICAL NOTE 26 DESIGN VALUES FOR STRUCTURAL GLUED LAMINATED TIMBER IN EXISTING STRUCTURES December 2007

AITC TECHNICAL NOTE 26 DESIGN VALUES FOR STRUCTURAL GLUED LAMINATED TIMBER IN EXISTING STRUCTURES December 2007 AITC TECHNICAL NOTE 26 DESIGN VALUES FOR STRUCTURAL GLUED LAMINATED TIMBER IN EXISTING STRUCTURES December 2007 AMERICAN INSTITUTE OF TIMBER CONSTRUCTION 7012 S. Revere Parkway Suite 140 Centennial, CO

More information

SECTION PLATE CONNECTED WOOD TRUSSES

SECTION PLATE CONNECTED WOOD TRUSSES SECTION 06173 PLATE CONNECTED WOOD TRUSSES PART 1 GENERAL 1.01 SUMMARY A. Section Includes: 1. Shop fabricated wood trusses for roof and floor framing. 2. Bridging, bracing, and anchorage. B. Related Sections:

More information

Fundamentals of Wood Design and Engineering

Fundamentals of Wood Design and Engineering Fundamentals of Wood Design and Engineering Session 3 Wood Design Introduction to Wood Engineering; Codes & Standards; Load combinations, weights of building materials and tributary area; Simple beam design:

More information

American Institute of Timber Construction 7012 South Revere Parkway Suite 140 Centennial, CO Phone: 303/ Fax: 303/

American Institute of Timber Construction 7012 South Revere Parkway Suite 140 Centennial, CO Phone: 303/ Fax: 303/ 7012 South Revere Parkway Suite 140 Centennial, CO 80112 form per section/change. All information is mandatory, failure to include all information may result in your ballot being excluded from consideration

More information

ANSI Standard Specification for Structural Glued Laminated Tımber of Softwood Species

ANSI Standard Specification for Structural Glued Laminated Tımber of Softwood Species ANSI 117-2010 american national standard Standard Specification for Structural Glued Laminated Tımber of Softwood Species American National Standard Approval of an American National Standard requires review

More information

WOOD I-JOIST AWARENESS GUIDE

WOOD I-JOIST AWARENESS GUIDE WOOD I-JOIST AWARENESS GUIDE American Wood Council Flange Web Flange American Forest & Paper Association WOOD I-JOIST AWARENESS GUIDE The American Wood Council is part of the wood products group of the

More information

SDPWS. Special Design Provisions for Wind & Seismic 2015 EDITION

SDPWS. Special Design Provisions for Wind & Seismic 2015 EDITION SDPWS Special Design Provisions for Wind & Seismic 2015 EDITION ANSI/AWC SDPWS-2015 Approval date September 8, 2014 Updates and Errata While every precaution has been taken to ensure the accuracy of this

More information

GLOBAL LVL HEADERS, BEAMS AND COLUMNS. 1.9E-2850Fb. 1.9E-2850Fb. User guide User guide. lvlglobal.com

GLOBAL LVL HEADERS, BEAMS AND COLUMNS. 1.9E-2850Fb. 1.9E-2850Fb. User guide User guide. lvlglobal.com GLOBAL LVL HEADERS, BEAMS AND COLUMNS 1.9E-2850Fb GLOBAL LVL HEADERS, BEAMS AND COLUMNS 1.9E-2850Fb User guide User guide lvlglobal.com Global LVL, the product of choice for all of your residential, commercial

More information

Structural Design for Wind Loads: An Overview of Engineering Considerations for Wood

Structural Design for Wind Loads: An Overview of Engineering Considerations for Wood Structural Design for Wind Loads: An Overview of Engineering Considerations for Wood Lori Koch, PE Manager, Educational Outreach American Wood Council Buildings Copyright Materials This presentation is

More information

Principles of STRUCTURAL DESIGN. Wood, Steel, and Concrete SECOND EDITION RAM S. GUPTA. CRC Press. Taylor& Francis Group

Principles of STRUCTURAL DESIGN. Wood, Steel, and Concrete SECOND EDITION RAM S. GUPTA. CRC Press. Taylor& Francis Group SECOND EDITION Principles of STRUCTURAL DESIGN Wood, Steel, and Concrete RAM S. GUPTA CRC Press Taylor& Francis Group Boca Raton London New York CRC Press is an imprint of the Taylor & Francis Croup, an

More information

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: SHOP FABRICATED STRUCTURAL WOOD REPORT HOLDER: SWEET S JOISTS, INC.

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: SHOP FABRICATED STRUCTURAL WOOD REPORT HOLDER: SWEET S JOISTS, INC. 0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 2504 Reissued 05/2018 This report is subject to renewal 05/2019. DIVISION: 06 00

More information

Murphy LVL Limit States Design Guide 2.0 E-LVL 2.2 E-LVL

Murphy LVL Limit States Design Guide 2.0 E-LVL 2.2 E-LVL Murphy LVL Limit States Design Guide 2.0 E-LVL 2.2 E-LVL Our Company At Murphy Company we take pride in providing our customers with premium quality products and services. Our LVL is manufactured to provide

More information

PRODUCT: Structural Insulated Panels (SIP) DIVISION: Wood and Plastics (06) SECTION: Structural Panels ( )

PRODUCT: Structural Insulated Panels (SIP) DIVISION: Wood and Plastics (06) SECTION: Structural Panels ( ) PRODUCT: Structural Insulated Panels (SIP) DIVISION: Wood and Plastics (06) SECTION: Structural Panels (06 12 16) Report Holder General Panel Corporation PO Box 279 2604 Sunset Drive Grenada, Mississippi

More information

Mid-Rise Engineering Considerations for Engineered Wood Products

Mid-Rise Engineering Considerations for Engineered Wood Products Mid-Rise Engineering Considerations for Engineered Wood Products Presented by Frank Powell, P.E. Presented by [ Presenter s Name ] Please add relevant logo here Disclaimer: This presentation was developed

More information

INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS, EVALUATION SERVICES EVALUATION CRITERIA FOR STEEL ROOF DECK.

INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS, EVALUATION SERVICES EVALUATION CRITERIA FOR STEEL ROOF DECK. INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS, EVALUATION SERVICES EVALUATION CRITERIA FOR STEEL ROOF DECK EC 007-2010 e1 1.0 INTRODUCTION 1.1 Purpose: This criteria establishes the requirements

More information

WIND & SEISMIC 2008 EDITION ASD/LRFD WITH COMMENTARY. American Forest & Paper Association. American Wood Council ANSI/AF&PA SDPWS-2008

WIND & SEISMIC 2008 EDITION ASD/LRFD WITH COMMENTARY. American Forest & Paper Association. American Wood Council ANSI/AF&PA SDPWS-2008 2008 EDITION ANSI/AF&PA SDPWS-2008 Approval Date: August 4, 2008 ASD/LRFD WIND & SEISMIC Special Design Provisions for Wind and Seismic WITH COMMENTARY American Forest & Paper Association American Wood

More information

Statewide Alternate Method January 2015 No Cross-Laminated Timber Provisions

Statewide Alternate Method January 2015 No Cross-Laminated Timber Provisions Statewide Alternate Method January 2015 No. 15-01 Cross-Laminated Timber Provisions (Ref.: ORS 455.060) Statewide Alternate Methods are approved by the Division administrator in consultation with the appropriate

More information

Technical Data for. Headers. and Beams

Technical Data for. Headers. and Beams L A M I N A T E D V E N E E R L U M B E R Technical Data for Headers and Beams E A S T E R N E N G I N E E R E D W O O D P R O D U C T S OUR COMPANY Our total focus on engineered wood products and providing

More information

Temporary Structures. Form Materials and Accessories ATCE--II. Advanced Topics in Civil Engineering Form Materials and Accessories ATCE-II

Temporary Structures. Form Materials and Accessories ATCE--II. Advanced Topics in Civil Engineering Form Materials and Accessories ATCE-II Temporary Structures Form Materials and Accessories Practically all formwork jobs require some lumber. Local supplier will advise what material and sizes are in stock or promptly obtainable, and the designer

More information

WIND & SEISMIC 2008 EDITION ASD/LRFD WITH COMMENTARY. American Forest & Paper Association. American Wood Council ANSI/AF&PA SDPWS-2008

WIND & SEISMIC 2008 EDITION ASD/LRFD WITH COMMENTARY. American Forest & Paper Association. American Wood Council ANSI/AF&PA SDPWS-2008 2008 EDITION ANSI/AF&PA SDPWS-2008 Approval Date: August 4, 2008 ASD/LRFD WIND & SEISMIC Special Design Provisions for Wind and Seismic WITH COMMENTARY American Forest & Paper Association Updates and Errata

More information

LVL Product Guide 2.0E LVL 1.5E LVL

LVL Product Guide 2.0E LVL 1.5E LVL LVL Product Guide 2.0E LVL 1.5E LVL Our Company Anthony Forest Products Company, a family-owned business founded in 1916, is headquartered in El Dorado, Arkansas. The company operates a southern pine lumber

More information

PRODUCT: Structural Insulated Panels (SIPs) DIVISION: Wood, Plastics, and Composites (06) SECTION: Structural Panels ( )

PRODUCT: Structural Insulated Panels (SIPs) DIVISION: Wood, Plastics, and Composites (06) SECTION: Structural Panels ( ) PRODUCT: Structural Insulated Panels (SIPs) DIVISION: Wood, Plastics, and Composites (06) SECTION: Structural Panels (06 12 00) Report Holder ACME Panel Company 1905 West Main St. Radford, VA 24141 Manufacturing

More information

LPI 56 Technical Guide

LPI 56 Technical Guide LPI 56 Technical Guide Floor & Roof Applications Product Specifications & Design Values 2 Floor Tables 3 Uniform Floor Load (PLF) Tables: Simple s 4 Uniform Floor Load (PLF) Tables: Continuous s 5 Uniform

More information

Evaluation Report CCMC R Murphy LVL

Evaluation Report CCMC R Murphy LVL Evaluation Report CCMC 13507-R Murphy LVL MasterFormat: 06 17 10 Evaluation issued: 2010-10-27 Re-evaluated: 2016-04-18 Revised: 2017-10-18 Re-evaluation due: 2016-10-27 1. Opinion It is the opinion of

More information

Trusted ICC ES TEK USA, Evaluation. report, or as to any. ICC-ES Evaluation

Trusted ICC ES TEK USA, Evaluation. report, or as to any. ICC-ES Evaluation 0 ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.orgg Most Widely Accepted and Trusted ESR 3105 Reissued 08/2017 Revised 10/2018 This report is subject to renewal 08/2019.

More information

REPORT HOLDER: MITEK USA, INC. (FORMERLY USP STRUCTURAL CONNECTORS) SOUTHCROSS DRIVE, SUITE 200 BURNSVILLE, MINNESOTA EVALUATION SUBJECT:

REPORT HOLDER: MITEK USA, INC. (FORMERLY USP STRUCTURAL CONNECTORS) SOUTHCROSS DRIVE, SUITE 200 BURNSVILLE, MINNESOTA EVALUATION SUBJECT: 0 Most Widely Accepted and Trusted ICC-ES Evaluation Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org ESR-2787 Reissued 05/2017 This report is subject to renewal 05/2019. DIVISION: 03 00

More information

April 2, 2018 PARTIES INTERESTED IN CROSS LAMINATED TIMBER PANELS USED AS COMPONENTS IN FLOOR AND ROOF DECKS

April 2, 2018 PARTIES INTERESTED IN CROSS LAMINATED TIMBER PANELS USED AS COMPONENTS IN FLOOR AND ROOF DECKS April 2, 2018 TO: PARTIES INTERESTED IN CROSS LAMINATED TIMBER PANELS USED AS COMPONENTS IN FLOOR AND ROOF DECKS SUBJECT: Proposed Revisions to the ICC-ES Acceptance Criteria for Cross-laminated Timber

More information

Tr T e r a e t a e t d e d G l G u l l u a l m a

Tr T e r a e t a e t d e d G l G u l l u a l m a Treated Glulam Eastern Engineered Wood Products Our total focus on the engineered wood products business is what distinguishes us. At Eastern Engineered Wood Products we take pride in providing our customers

More information

BROADSPAN. LVL Design Brochure. Design properties for LVL header and beam applications in the U.S. for residential floor and roof systems

BROADSPAN. LVL Design Brochure. Design properties for LVL header and beam applications in the U.S. for residential floor and roof systems BROADSPAN LVL Design Brochure Design properties for LVL header and beam applications in the U.S. for residential floor and roof systems LVL Design Brochure Product Line You ve probably been building with

More information

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: NAILS REPORT HOLDER: HY-TEK FASTENERS INC. EVALUATION SUBJECT: HY-TEK NAILS

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: NAILS REPORT HOLDER: HY-TEK FASTENERS INC. EVALUATION SUBJECT: HY-TEK NAILS 0 ICC-ES Evaluation Report ICC-ES 000 (800) 423-6587 (562) 699-0543 www.icc-es.org Most Widely Accepted and Trusted ESR-2648 Reissued 06/2018 Revised 10/24/2018 This report is subject to renewal 06/2020.

More information

Introduction to Structural Analysis TYPES OF STRUCTURES LOADS AND

Introduction to Structural Analysis TYPES OF STRUCTURES LOADS AND AND Introduction to Structural Analysis TYPES OF STRUCTURES LOADS INTRODUCTION What is the role of structural analysis in structural engineering projects? Structural engineering is the science and art

More information

OUR COMPANY OUR WARRANTY OUR GUARANTEE

OUR COMPANY OUR WARRANTY OUR GUARANTEE DESIGN MANUAL-USA FRAMED BY QUALITY BUILT WITH SUCCESS OUR COMPANY At International Beams Inc. we take pride in providing our customers with premium quality products and services. Our full range of engineered

More information

Joint Evaluation Report ICC-ES (800) (562)

Joint Evaluation Report ICC-ES (800) (562) 0 Joint Evaluation Report ICC-ES (800) 423-6587 (562) 699-0543 www.icc-es.org 000 ESR-1336 Reissued 09/2016 This report is subject to renewal 09/2018. DIVISION: 06 00 00 WOOD, PLASTICS AND COMPOSITES SECTION:

More information

NORDIC ENGINEERED WOOD NON-RESIDENTIAL DESIGN CONSTRUCTION GUIDE NORDIC LAMTM FSC-CERTIFIED PRODUCTS AVAILABLE

NORDIC ENGINEERED WOOD NON-RESIDENTIAL DESIGN CONSTRUCTION GUIDE NORDIC LAMTM FSC-CERTIFIED PRODUCTS AVAILABLE NORDIC ENGINEERED WOOD NON-RESIDENTIAL DESIGN CONSTRUCTION GUIDE NORDIC LAMTM FSC-CERTIFIED PRODUCTS AVAILABLE BRINGING NATURE S RESOURCES HOME Nordic Engineered Wood was founded in the year 2000 to develop

More information

PR-L274 Nordic Structures Revised April 16, 2017

PR-L274 Nordic Structures Revised April 16, 2017 Nordic TM PR-L274 Nordic Structures Revised April 16, 2017 Products: NI-20, 40, 40x, 60, 70, 80, 80x, 90, and 90x Prefabricated Wood I-s Nordic Structures 1100 Avenue des Canadiens-de-Montréal, Suite 504

More information

ICC-ES Evaluation Report Reissued September 1, 2011 This report is subject to renewal in two years.

ICC-ES Evaluation Report Reissued September 1, 2011 This report is subject to renewal in two years. ICC-ES Evaluation Report www.icc-es.org (800) 423-6587 (562) 699-0543 ESR-1336 Reissued September 1, 2011 This report is subject to renewal in two years. A Subsidiary of the International Code Council

More information

Fire Resistive Design of Exposed Timber Structures

Fire Resistive Design of Exposed Timber Structures Fire Resistive Design of Exposed Timber Structures Heavy Timber & One Hour Fire Rating Paul C. Gilham, P.E., S.E. Western Wood Structures, Inc. The Wood Products Council is a Registered Provider with The$

More information

GLULAM DESIGN PROPERTIES AND LAYUP COMBINATIONS

GLULAM DESIGN PROPERTIES AND LAYUP COMBINATIONS GLULAM DESIGN PROPERTIES AND LAYUP COMBINATIONS ENGINEERED WOOD SYSTEMS 2001 ENGINEERED WOOD SYSTEMS ALL RIGHTS RESERVED. ANY COPYING, MODIFICATION, DISTRIBUTION OR OTHER USE OF THIS PUBLICATION OTHER

More information

GLULAM DESIGN PROPERTIES AND LAYUP COMBINATIONS

GLULAM DESIGN PROPERTIES AND LAYUP COMBINATIONS GLULAM DESIGN PROPERTIES AND LAYUP COMBINATIONS ENGINEERED WOOD SYSTEMS WOOD The Miracle Material Wood is the right choice for a host of construction applications. It is the earth s natural, energy efficient

More information

Maximum Spans Southern Pine Joists & Rafters

Maximum Spans Southern Pine Joists & Rafters Maximum Spans Southern Pine Joists & Rafters VISUALLY GRADED LUMBER MACHINE STRESS RATED (MSR) MACHINE EVALUATED LUMBER (MEL) www.southernpine.com CONTENTS INDEX TO TABLES Floor and Rafter Framing Diagrams.......

More information

Wood Solutions Fair, 2014, Toronto

Wood Solutions Fair, 2014, Toronto Overview of Changes to CSA O86-2014 & Structural Design Provisions for Mid-Rise in OBC Wood Solutions Fair, 2014, Toronto Jasmine Wang, Ph.D., P.Eng. Canadian Wood Council Copyright Materials This presentation

More information

S TRUCTURAL W OOD D ESIGN

S TRUCTURAL W OOD D ESIGN S TRUCTURAL W OOD D ESIGN Structural Wood Design: A Practice-Oriented Approach Using the ASD Method. Abi Aghayere and Jason Vigil Copyright 2007 John Wiley & Sons, Inc. S TRUCTURAL W OOD D ESIGN A PRACTICE-ORIENTED

More information

ARCH 331. Study Guide for Final Examination

ARCH 331. Study Guide for Final Examination ARCH 331. Study Guide for Final Examination This guide is not providing answers for the conceptual questions. It is a list of topical concepts and their application you should be familiar with. It is an

More information

LRFD EXAMPLE PROBLEMS FOR WOOD STRUCTURES LOAD AND RESISTANCE FACTOR DESIGN

LRFD EXAMPLE PROBLEMS FOR WOOD STRUCTURES LOAD AND RESISTANCE FACTOR DESIGN LRFD LOAD AND RESISTANCE FACTOR DESIGN EXAMPLE PROBLEMS FOR WOOD STRUCTURES American Forest & Paper Association Southern Forest Products Association Wood Truss Council of America In Cooperation with the

More information

KING BEAM 3000 and BOISE GLULAM PR-L313 Boise Cascade Wood Products, L.L.C. Revised May 29, 2017

KING BEAM 3000 and BOISE GLULAM PR-L313 Boise Cascade Wood Products, L.L.C. Revised May 29, 2017 KING BEAM 3000 and BOISE GLULAM PR-L313 Boise Cascade Wood Products, L.L.C. Revised May 29, 2017 Products: KING BEAM 3000 and BOISE GLULAM Boise Cascade Wood Products, L.L.C., P.O. Box 185, 4318 Pioneer

More information

VARIOUS TYPES OF SLABS

VARIOUS TYPES OF SLABS VARIOUS TYPES OF SLABS 1 CHOICE OF TYPE OF SLAB FLOOR The choice of type of slab for a particular floor depends on many factors. Economy of construction is obviously an important consideration, but this

More information

2015 Special Design Provisions for Wind and Seismic Philip Line, P.E., John Buddy Showalter, P.E., Michelle Kam-Biron, P.E., S.E., Jason Smart, P.E.

2015 Special Design Provisions for Wind and Seismic Philip Line, P.E., John Buddy Showalter, P.E., Michelle Kam-Biron, P.E., S.E., Jason Smart, P.E. 2015 Special Design Provisions for Wind and Seismic Philip Line, P.E., John Buddy Showalter, P.E., Michelle Kam-Biron, P.E., S.E., Jason Smart, P.E. The 2015 Edition of Special Design Provisions for Wind

More information

Analysis of Glulam Timber Beams with Mechanically Graded (E-rated) Outer Laminations

Analysis of Glulam Timber Beams with Mechanically Graded (E-rated) Outer Laminations In: Gopu, Vijaya K.A., ed. Proceedings of the international wood engineering conference; 1996 October 28-31; New Orleans, LA. Baton Rouge, LA: Louisiana State University: Vol. 1: 144-150 Analysis of Glulam

More information

Featuring Selection and Installation Information for Lateral Wind Loads

Featuring Selection and Installation Information for Lateral Wind Loads #TJ-8000 SPECIFIER S GUIDE 1¼" TIMBERSTRAND LSL RIM BOARD AND 1 1 8" TJ RIM BOARD Featuring Selection and Installation Information for Lateral Wind Loads For Use in ASCE/SEI 7-05 Basic Wind Speed Regions

More information

Steel Roof Deck EC X

Steel Roof Deck EC X IAPMO ES Cover Sheet Evaluation Criteria of Steel Roof Deck EC 007-200 Posted for public commenting on 10/16/2009 to 11/12/2009 INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS, EVALUATION

More information

Evaluation Report CCMC R Parallam PSL

Evaluation Report CCMC R Parallam PSL Evaluation Report CCMC 11161-R Parallam PSL MasterFormat: 06 17 10 Evaluation issued: 1986-04-03 Re-evaluated: 2015-05-25 Revised: 2017-01-11 Re-evaluation due: 2017-06-14 1. Opinion It is the opinion

More information

Evaluation Listing CCMC L Nordic X-Lam

Evaluation Listing CCMC L Nordic X-Lam CONSTRUCTION Evaluation Listing CCMC 3654-L Nordic X-Lam Evaluation Issued: 203-2-24 Re-evaluation due: 206-2-24 Preface: Masterformat 06 9 00.02, Cross Laminated Timber (CLT) Panels (Standardized) Preface

More information

VOLUNTARY - EARTHQUAKE HAZARD REDUCTION IN EXISTING HILLSIDE BUILDINGS (Division 94 Added by Ord. No. 171,258, Eff. 8/30/96.)

VOLUNTARY - EARTHQUAKE HAZARD REDUCTION IN EXISTING HILLSIDE BUILDINGS (Division 94 Added by Ord. No. 171,258, Eff. 8/30/96.) DIVISION 94 VOLUNTARY - EARTHQUAKE HAZARD REDUCTION IN EXISTING HILLSIDE BUILDINGS (Division 94 Added by Ord. No. 171,258, Eff. 8/30/96.) SEC. 91.9401. PURPOSE. (Amended by Ord. No. 172,592, Eff. 6/28/99,

More information

Metal-plate connections loaded in combined bending and tension

Metal-plate connections loaded in combined bending and tension Metal-plate connections loaded in combined bending and tension Ronald W. Wolfe Abstract This study evaluates the load capacity of metal-plate connections under combined bending and axial loads and shows

More information

FIGURE R502.2 FLOOR CONSTRUCTION

FIGURE R502.2 FLOOR CONSTRUCTION CHAPTER 5 FLOORS 11 I SECTION R501 GENERAL R501.1 Application. The provisions of this chapter shall control the design and construction of the floors for all buildings including the floors of attic spaces

More information

INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS UNIFORM EVALUATION SERVICE EVALUATION CRITERIA FOR

INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS UNIFORM EVALUATION SERVICE EVALUATION CRITERIA FOR INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS UNIFORM EVALUATION SERVICE EVALUATION CRITERIA FOR SINGLE SKIN STEEL ROOF AND WALL PANELS EC 011-2015 (Adopted - September 2013, Revision

More information

Pacific Woodtech Corporation Revised January 26, 2018

Pacific Woodtech Corporation Revised January 26, 2018 PWI s PR-L262 Pacific Woodtech Corporation Revised January 26, 2018 Products: PWI-20, 30, 40, 45, 47, 50, 60, 70, 77, 77w, and 90 Series I-joists Pacific Woodtech Corporation, 1850 Park Lane, Burlington,

More information

A Guide for the Interpretation of Structural Design Options for Residential Concrete Structures

A Guide for the Interpretation of Structural Design Options for Residential Concrete Structures CFA Technical Note: 008-2010 A Guide for the Interpretation of Structural Design Options for Residential Concrete Structures CFA Technical This CFA Technical Note is intended to serve as a guide to assist

More information

Heel Blocking Requirements and Capacity Analysis. Overview Revised 3/22/2017

Heel Blocking Requirements and Capacity Analysis. Overview Revised 3/22/2017 Heel Blocking Requirements and Capacity Analysis Overview Revised 3/22/2017 SBCA has been the voice of the structural building components industry since 1983, providing educational programs and technical

More information

Joint Evaluation Report ICC-ES (800) (562)

Joint Evaluation Report ICC-ES (800) (562) 0 Joint Evaluation Report ICC-ES (800) 423-6587 (562) 699-0543 www.icc-es.org 000 ESR-3631 Reissued 09/2018 This report is subject to renewal 09/2019. DIVISION: 06 00 00 WOOD, PLASTICS AND COMPOSITES SECTION:

More information

STEEL DESIGNERS MANUAL

STEEL DESIGNERS MANUAL STEEL DESIGNERS MANUAL SIXTH EDITION The Steel Construction Institute Edited by Buick Davison Department of Civil & Structural Engineering, The University of Sheffield Graham W. Owens Director, The Steel

More information

ANSI A Standard for Wood Products Structural Glued Laminated Tımber

ANSI A Standard for Wood Products Structural Glued Laminated Tımber ANSI A190.1-2017 american national standard Standard for Wood Products Structural Glued Laminated Tımber American National Standard Approval of an American National Standard requires review by ANSI that

More information

2.2E Parallam PSL Deep Beam

2.2E Parallam PSL Deep Beam #TJ-7001 SPECIFIER S GUIDE 2.2E Parallam PSL Deep Beam Featuring 20" 24" Deep Trus Joist Parallam PSL Beams Ideal for multi-family and light commercial applications Offers high strength and consistent

More information

ASD and LRFD with the 2005 NDS

ASD and LRFD with the 2005 NDS ASD and LRFD with the 2005 NDS Copyright 2005 American Forest & Paper Association, Inc. Welcome to the 2005 NDS! See what s new inside 1 Outline Document layout Chapter-by-chapter description Changes from

More information

Lintels and Beams: Engineering Basis

Lintels and Beams: Engineering Basis Lintels and Beams: Engineering Basis The calculator is intended for the design of lintels and beams in timber- framed buildings generally within the scope of NZS 3604. However, the range of applications,

More information

LIMIT STATES DESIGN INFORMATION for Specific Engineering Design for New Zealand Construction

LIMIT STATES DESIGN INFORMATION for Specific Engineering Design for New Zealand Construction technical certificate LIMIT STATES DESIGN INFORMATION for Specific Engineering Design for New Zealand Construction Technical Note 82-07-04 (Replaces 82-07-02, 82-06-06, 06-03-82, 98-01-39 and 05-11-39)

More information

Load Design Charts. R-CONTROL SIPs STRUCTURAL INSULATED PANELS. CONTROL, NOT COMPROMISE.

Load Design Charts. R-CONTROL SIPs STRUCTURAL INSULATED PANELS.   CONTROL, NOT COMPROMISE. R-CONTROL s STRUCTURAL INSULATED PANELS Note: Information deemed reliable at time of printing. Please visit www.r-control.com for latest information. June 2012 CONTROL, NOT COMPROMISE. www.r-control.com

More information

The LP Family of Sub-Flooring

The LP Family of Sub-Flooring The P Family of Sub-Flooring UNIQUE TO TOPNOTCH Our RainChannel notch system helps protect against moisture absorption and edge swell. Engineered specifically for sub-flooring applications Designed for

More information

Anchor bolts ASTM F1554, Gr. 36 Wide flange beams ASTM A992, Fy = 50 ksi Misc. structural steel ASTM A36, Fy = 36 ksi

Anchor bolts ASTM F1554, Gr. 36 Wide flange beams ASTM A992, Fy = 50 ksi Misc. structural steel ASTM A36, Fy = 36 ksi STRUCTURAL NOTES MATERIAL STRENGTHS Structural Steel Reinforcing Steel Concrete Masonry Structural Lumber Anchor bolts ASTM F1554, Gr. 36 Wide flange beams ASTM A992, Fy = 50 ksi Misc. structural steel

More information

Prescriptive Residential Wood Deck Construction Guide with Commentary DCA IRC Version (BCD 306)

Prescriptive Residential Wood Deck Construction Guide with Commentary DCA IRC Version (BCD 306) Prescriptive Residential Wood Deck Construction Guide with Commentary DCA 6-2015 IRC Version (BCD 306) Loren Ross P.E. Manager, Engineering Research American Wood Council Copyright Materials This presentation

More information

Stora Enso S-LVL Laminated Veneer Lumber (LVL) TER No

Stora Enso S-LVL Laminated Veneer Lumber (LVL) TER No (LVL) TER No. 1507-01 Stora Enso Wood Products Oy Ltd. Kanavaranta 1 PO Box 309 Helsinki Finland FL-00101 buildingandliving.storaenso.com Issue Date: February 7, 2017 Updated: May 1, 2018 Subject to Renewal:

More information

Trusted WOOD I JOISTS SECTION: 06 ON WEB i. Conformity! ICC-ES Evaluation. Copyright 2015

Trusted WOOD I JOISTS SECTION: 06 ON WEB i. Conformity! ICC-ES Evaluation. Copyright 2015 0 ICC ES Report ICC ES (800) 42 6587 (562) 699 054 www.icc es.orgg 000 Most Widely Accepted and Trusted ESR 2974 Reissued 07/4 This report is subject to renewal 07/5. DIVISION: 06 00 00 WOOD, PLASTICS

More information