Perforated. Perforated 47. Applications Education Healthcare Hotels Leisure Office Retail

Size: px
Start display at page:

Download "Perforated. Perforated 47. Applications Education Healthcare Hotels Leisure Office Retail"

Transcription

1 46 Perforated Perforated 47 ASTM E 1264 classification, Type III, Form 2, Pattern C,E. Accessible acoustical ceiling system with pin perforted panels. Mid range sound absorption, provides balance to room acoustics Mid range sound attenuation, ideal for general commercial construction Maximum economy and design simplicity Easy to trim and install Healthcare Hotels Leisure Office etail a patented process blend of NC mineral fiber, organic binders. Pre-finished with primer and top coat paints. Manufactured in water felted mineral fiber technology. Material safety data sheet available on request. Perforated Perforated Perforated *Type: : egular SLT 24 x 24 x 3/4 PS 665 PS 225 PS 669 PS 229 PS 665 PS % 84% 84% E Fire eaction BS 476 Pt 6/7 Class 1/0 ASTM E84, Class A Flame spread: 25 Smoke developed: 15 Fire resistance egular BS 476 Pt min. protection to steel beams and timber floor. Humidity esistance Maximum 90% H / 32 C Thermal esistance 0.33 m 2 C/W kg/m 2 (egular) for 15mm panel Maintenance Easily cleaned using soft brush or vacuum. Class D Hz αs egular 15mm αw = 0.5 Perforted/DONN DX24

2 48 Plain Plain 49 ASTM E 1264 classification, Type III, Form 2, Pattern C,E. Accessible acoustical ceiling system with plain finish panels Low sound absorption, ideal where increased room reverberation is desired Mid range sound attenuation, ideal for general commercial construction High humidity resistant in ClimaPlus, suitable for applications with intermittent heating and cooling. May be installed early in the building program Fire resistant system options, for life safety and protection of property Easy to trim and install High light reflectance performance Healthcare Hotels Leisure Office etail a patented process blend of NC mineral fiber, organic binders. Pre-finished with primer and top coat paints. Manufactured in water felted mineral fiber technology. Material safety data sheet available on request. Fire eaction BS 476 Pt 6/7 Class 1/0 ASTM E84, Class A Flame spread: 25 Smoke developed: 15 Fire resistance egular BS 476 Pt min. protection to steel beams and timber floor. Humidity esistance Maximum 90% H / 32 C (ClimaPlus) Thermal esistance 0.37 m 2 C/W kg/m 2 (egular / ClimaPlus 15mm) Maintenance Easily cleaned using soft brush or vacuum. Plain Plain Plain Plain *Type: : egular SLT ILT FL BS 665 BS 225 BS 665 BS 225 BSI 665 BSI 225 BSF 665 BSF Hz αs αw = % 85% 85% 85% E E H, J Class E Plain/DONN DX24

3 50 Sonatone Sparta Sonatone Sparta 51 Plain Star Plus ASTM E 1264 classification, Type XII, Form 1, Pattern E. Accessible acoustical ceiling system with smooth and textured laminated panels Durable laminated construction High light reflectance, to improve lighting efficiency. Lightweight for easy handling Ultra high humidity resistant and sag resistance Scrub resistant. Dirt marks are easy to remove. Scuff and scratch resistant, for longer life Easy to trim and install Healthcare / Laboratories Hotels Leisure Office etail a patented process blend of NC mineral fiber, organic binders. Pre-finished with primer and PVC facing. Manufactured in water felted mineral fiber technology.material safety data sheet available on request Humidity esistance Maximum 95% H / 32 C Plain Plain Star Plus 24 x 24 x5/8 Star Plus 24 x 24 x3/4 *Type: : egular. Note: Other thicknesses available on request. 600 x600 x x 24 x3/4 LPW 665 LPW 225 LPW 669 LPW 229 LSP 665 LSP 225 LSP 669 LSP % 84% 84% 84% Thermal esistance 0.37 m 2 C/W kg/m 2 for 15mm panel, regular quality. Maintenance: Easily cleaned using soft brush or vacuum, or a damp sponge. Hz αs Sonatone/DONN DX24

4 52 Cross Fissured Cross Fissured 53 ASTM E 1264 classification, Type III, Form 2, Pattern C,D. a patented process blend of NC mineral fiber, organic binders. Pre-finished with primer and top coat paints. Manufactured in water felted mineral fiber technology. Material safety data sheet available on request. Fire eaction BS 476 Pt 6/7 Class 1/0 ASTM E84, Class A Flame spread: 25 Smoke developed: 10 Fire resistance egular BS 476 Pt min. protection to steel beams and timber floor. Firecode BS 476 Pt 21/ min. protection to steel beams and timber floor. Humidity esistance Maximum 70% H / 32 C (egular) Maximum 90% H / 32 C (ClimaPlus) Thermal esistance 0.33 m 2 C/W 1.4 (egular / ClimaPlus ) 0.37 m 2 C/W 1.6 (Firecode) 3.50 kg/m 2 (egular / ClimaPlus 15mm), 5.00 kg/m 2 (Firecode 15mm) 4.50 kg/m 2 (egular / ClimaPlus 19mm) 6.10 kg/m 2 (Firecode 19mm) Maintenance Easily cleaned using soft brush or vacuum. Accessible acoustical ceiling system with directional fissured panels Maximum economy and design simplicity Mid range sound absorption, provides balance to room acoustics Mid range sound attenuation, ideal for general commercial construction Easy to trim and install Cross Fissured Cross Fissured Cross Fissured - Climaplus Cross Fissured - Climaplus Cross Fissured - Climaplus Cross Fissured - Climaplus Cross Fissured - Firechief CP CP CP CP FC Cross Fissured - Firechief FC 24 x 24 x 3/4 *Type : : egular, CP: ClimaPlus, FC: Firecode. SLT SLT 24 x 24 x 5/8 24 x 24 x5/8 600 x 1200 x x 48 x5/8 24 x 24 x3/4 24 x 24 x 3/4 24 x 24 x 5/8 CFS 665 CFS 225 CFS 665 CFS 225 CFC 665 CFC 225 CFC 625 CFC 245 CFC 669 CFC 229 CFC 669 CFC 229 CFX 665 CFX225 CFX 669 CFX 229 Healthcare Mass Merchandisers Convenience Stores Administrative Office etail / Corridors Hz αs egular 15 mm αw= 0.45 αs Firecode 15 mm αw= 0.4 αs egular 19 mm αw= % 82% 82% 82% 82% 82% 82% 82% E E Class C for 19mm Class D for 15mm Cross Fissured/DONN DX24

5 54 Favia Favia 55 ASTM E 1264 classification, Type III, Form 2, Pattern C,D,E. a patented process blend of NC mineral fiber, organic binders. Pre-finished with primer and top coat paints. Manufactured in water felted mineral fiber technology. Material safety data sheet available on request. Fire eaction BS 476 Pt 6/7 Class 1/0 ASTM E84, Class A Flame spread: 25 Smoke developed: 15 Fire resistance egular BS 476 Pt min. protection to steel beams and timber floor. Humidity esistance Maximum 90% H / 32 C Thermal esistance 0.33 m 2 C/W kg/m 2 (egular 15mm) Accessible acoustical ceiling system with fine non-directional fissured panel Mid sound absorption, for effective reduction of unwanted noise Mid range sound attenuation, ideal for general commercial construction High humidity resistant in ClimaPlus, suitable for applications with intermittent heating and cooling. May be installed early in the building program Fire resistant system options, for life safety and protection of property Durable fully painted and sealed rebated edge options, ideal for frequently accessed ceilings Easy to trim and install Favia Favia *Type: : egular **All items are available in 15mm(5/8 ) only. SLT FNS 665 FNS 225 FNS 665 FNS 225 Healthcare Hotels Leisure Administrative Office etail / Corridors Mass Merchandisers Stores Hz αs egular αw = % 85% E Class D Maintenance Easily cleaned using soft brush or vacuum. Favia/DONN DX24

6 56 Favia Acoustic Favia Acoustic 57 ASTM E 1264 classification, Type III, Form 2, Pattern C,D,E. a patented process blend of NC mineral fiber, organic binders. Pre-finished with primer and top coat paints. Manufactured in water felted mineral fiber technology. Material safety data sheet available on request. Accessible acoustical ceiling system with fine non-directional fissured panel Mid to high sound absorption, for effective reduction of unwanted noise Mid range sound attenuation, ideal for general commercial construction High humidity resistant in ClimaPlus, suitable for applications with intermittent heating and cooling. May be installed early in the building program Fire resistant system options, for life safety and protection of property Durable fully painted and sealed rebated edge options, ideal for frequently accessed ceilings Easy to trim and install Favia Acoustic Favia Acoustic 24 x 24 x 3/4 FAS 665 FAS 225 FAS 669 FAS 229 Healthcare Hotels Stores Administrative Office etail / Mass Merchandisers % 75% Fire eaction BS 476 Pt 6/7 Class 1/0 ASTM E84, Class A Flame spread: 25 Smoke developed: 15 Favia Acoustic Favia Acoustic- ClimaPlus Favia Acoustic- ClimaPlus CP CP SLT ILT 24 x 24 x 5 / 8 24 x 24 x 3/4 FAS 665 FAS 225 FAC 669 FAC 229 FACI 665 FACI % 75 % 75 % E B1, E Fire resistance egular BS 476 Pt min. protection to steel beams and timber floor. Humidity esistance Maximum 90% H / 32 C Thermal esistance 0.37 m 2 C/W 1.7 for 19mm 0.33 m 2 C/W 1.4 for 15mm 3.50 kg/m 2 (egular / ClimaPlus 15mm) 4.50 kg/m 2 (egular / ClimaPlus 19mm) Favia Acoustic- ClimaPlus CP *Type: : egular, CP: ClimaPlus ILT 24 x 24 x 3/4 FACI 669 FACI Hz αs 15mm αw = 0.5 αs 19mm αw = % B1, E Class D for 15mm Class C for 19mm Maintenance Easily cleaned using soft brush or vacuum. Favia Acoustic/DONN DX24

7 58 adar adar 59 ASTM E 1264 classification, type III, Form 2, Pattern C, D, E a patented process blend of NC mineral fiber organic binders. Pre-finished wih primer and top coat paints. Manufactured in water felted, mineral fiber technology. Material safety data sheet available on request. Fire eaction BS 476 pt 6/7 Class 1/0 ASTM E84, Class A Flame spread: 25 Smoke developed: 15 Fire esistance egular BS 476 Pt min. protection to steel beams and timber floor. Firecode BS 476 Pt 21/ min. protection to steel beams and timber floor. Humidity esistance Maximum 90% H / 32 C Accessible acoustical ceiling system with fine non-directional fissured panel 360 non directional pattern with a fresh, clean appearance offers fast, economical installation Mid range sound absorption, provides balance to room acoustics Mid range sound attenuation, ideal for general commercial construction Fire resistant system options, for life safety and protection of property Easy to trim and install 600 x 1200 x 15 24"x 48"x 5/8" 24"x 24"x 5/8" 24"x 24"x 3/4" 24"x 24"x 5/8" Healthcare Hotels Leisure Office etail Thermal esistance 0.37 m² C/W (Firecode 19mm-15mm) 0.33 m² C/W (egular / ClimaPlus 15mm) Firechief FC 600 x 1200 x 15 24"x 48"x 5/8" DX 625 DX kg/m 2 (egular/climaplus) for 15mm panel 5.00 kg/m 2 (Firecode) for 15mm panel 4.50 kg/m 2 (egular/climaplus) for 19mm panel Maintenance: Easily cleaned using soft brush or vacuum αs αs αw = 0.5 αw = 0.6 adar/donn DX24

8 60 ocktone ocktone 61 ASTM E 1264 classification, type III, Form 2, Pattern C,D,E Accessible acoustical ceiling system with fine non-directional fissured panels 360 non directional pattern with a fresh, clean appearance offers fast, economical installation Mid range sound absorption, provides balance to room acoustics Mid range sound attenuation, ideal for general commercial construction Fire resistant system options, for life safety and protection of property Easy to trim and install Healthcare Hotels Leisure Office etail a patented process blend of NC mineral fiber organic binders. Pre-finished wih primer and top coat paints. Manufactured in water felted, mineral fiber technology. Material safety data sheet available on request. Fire eaction BS 476 pt 6/7 Class 1/0 ASTM E84, Class A Flame spread: 25 Smoke developed:15 Fire esistance BS 476 Pt min.protection to steel beams and timber floor. Humidity esistance Maximum 90% H / 32 C Thermal esistance 0.33 m² C/W (egular 15mm) 3.50 kg/m 2 (egular) for 15mm panel Maintenance: Easily cleaned using soft brush or vacuum ocktone Type: : egular S 665 S % Hz αs ocktone/donn DX15

9 62 Omni Omni 63 ASTM E 1264 classification, Type III, Form 2, Pattern C,D. a patented process blend of NC mineral fiber, organic binders. Pre-finished with primer and top coat paints. Manufactured in water felted mineral fiber technology. Material safety data sheet available on request. Fire eaction BS 476 Pt 6/7 Class 1/0 ASTM E84, Class A Flame spread: 25 Smoke developed: 15 Fire esistance egular BS 476 Pt min. protection to steel beams and timber floor. Firecode BS 476 Pt 21/ min. protection to steel beams and timber floor. Humidity esistance Maximum 90% H / 32 C Accessible acoustical ceiling system with fine non-directional fissured panels 360 non directional pattern with a fresh, clean appearance offers fast, economical installation. Mid range sound absorption, provides balance to room acoustics Mid range sound attenuation, ideal for general commercial construction Fire resistant system options, for life safety and protection of property Easy to trim and install Omni Omni Omni - Firechief *Type: : egular, FC: Firecode. FC 24 x 24 x 3/4 egular and Firecode panels are available in washable paint finish per ASTM D264 OMS 665 OMS 225 OMS 665W OMS 225W OMX 669 OMX 229 Healthcare Hotels Leisure Office etail Hz αs αs Available in "WATE SHIELD" application. egular 15mm αw = 0.5 Firecode 19mm αw = % 85% 85% Class D for 15mm Class C for 19mm Thermal esistance 0.33 m 2 C/W 1.4 for (egular / ClimaPlus 15mm) 0.37 m 2 C/W 1.7 for (Firecode 19mm) 3.50 kg/m 2 (egular / ClimaPlus 15mm) 5.00 kg/m 2 (Firecode 15mm) 6.10 kg/m 2 (Firecode 19mm) Maintenance Easily cleaned using soft brush or vacuum. Omni/DONN DX15

10 64 Chessboard Chessboard 65 ASTM E 1264 classification, Type III, Form 2, Pattern C,D,E,K. a patented process blend of NC mineral fiber, organic binders. Pre-finished with primer and top coat paints. Manufactured in water felted mineral fiber technology. Material safety data sheet available on request. Fire eaction BS 476 Pt 6/7 Class 1/0 ASTM E84, Class A Flame spread: 25 Smoke developed: 15 Fire resistance ClimaPlus BS 476 Pt 21/23 30 min. protection to steel beams and timber floor. Humidity esistance Maximum 90% H / 32 C Thermal esistance 0.37 m 2 C/W kg/m 2 (egular) Maintenance Easily cleaned using soft brush or vacuum. Accessible acoustical ceiling system with fine non-directional face cut panels Shallow geometric square or linear face cuts disguise the grid for a monolithic appearance Low sound absorption, ideal where increase room reverberation is desired Mid range sound attenuation, ideal for general commercial construction Easy to trim and install Chessboard *Type: : egular SLT CHS % E 24 x 24 x 3/4 CHS 229 Hz αs Healthcare Hotels Leisure Office etail Class E αw = 0.2 Chessboard/DONN DX24

11 66 Comet Line Comet Line 67 ASTM E 1264 classification, Type III, Form 2, Pattern C,D,E,K. a patented process blend of NC mineral fiber, organic binders. Pre-finished with primer and top coat paints. Manufactured in water felted mineral fiber technology. Material safety data sheet available on request. Fire eaction BS 476 Pt 6/7 Class 1/0 ASTM E84, Class A Flame spread: 25 Smoke developed: 15 Fire resistance egular BS 476 Pt min. protection to steel beams and timber floor. Humidity esistance Maximum 90% H / 32 C (ClimaPlus) Thermal esistance 0.37 m 2 C/W 1.7 Accessible acoustical ceiling system with fine directional face cut panels Shallow geometric square or linear face cuts disguise the grid for a monolithic appearance Low sound absorption, ideal where increased room reverberation is desired Mid range sound attenuation, ideal for general commercial construction Easy to trim and install Comet Line *Type: : egular SLT CS % E 24 x 24 x 3/4 CS 229 Hz αs Healthcare Hotels Leisure Office etail Class E αw = kg/m 2 (egular) Maintenance Easily cleaned using soft brush or vacuum. Comet Line/ DONN DX24

12 68 Designer Squares Designer Squares 69 ASTM E 1264 classification, Type III, Form 2, Pattern C,D,E,K. a patented process blend of NC mineral fiber, organic binders. Pre-finished with primer and top coat paints. Manufactured in water felted mineral fiber technology. Material safety data sheet available on request. Fire eaction BS 476 Pt 6/7 Class 1/0 ASTM E84, Class A Flame spread: 25 Smoke developed: 15 Fire resistance egular BS 476 Pt min. protection to steel beams and timber floor. Humidity esistance Maximum 90% H / 32 C Thermal esistance 0.33 m 2 C/W 4.25 kg/m 2 (egular 19mm) Maintenance Easily cleaned using soft brush or vacuum. Accessible acoustical ceiling system with fine non-directional fissured face cut panels Deep geometric square or linear face cuts disguise the grid for a monolithic appearance Mid - high sound absorption, for effective reduction of unwanted noise Mid range sound attenuation, ideal for general commercial construction High humidity resistant in ClimaPlus, suitable for applications with intermittent heating and cooling. May be installed early in the building program Easy to trim and install Designer Squares - Plain Designer Squares -36 Plain Designer Squares - 81 Plain Designer Squares - Favia Designer Squares - Perforated *Type : : egular SLT SLT FL SLT SLT 24 x 24 x 3/4 24 x 24 x 3/4 24 x 24 x 3/4 24 x 24 x 3/4 24 x 24 x 3/4 QBS 669 QBS 229 QBS 669 (36/15) QBS 229 (36/15) QBSF 669 (81/5) QBSF 229 (81/5) QFNS 669 QFNS 229 QPS 669 QPS 229 Healthcare Hotels Leisure Executive Office etail Hz αs Plain αw= 0.15 αs Perforted αw= % 88% 85% 83% 83% E E H, J E E Class C for Perforted Class E for Plain Designer Squares I/DONN DX15

13 70 Pedestals I Pedestals I 71 ASTM E 1264 classification, Type III, Form 1, Pattern E,L. Accessible acoustical ceiling system with plain textured stepped face cut panels Triple stepped face cuts adds depth and proportion to the ceiling Pedestals I, the look of 600 x 600 mm tiles Contemporary non perforated plain texture Mid range sound attenuation, ideal for general commercial construction Easy to install and cut Clean look for a rich looking ceiling Healthcare Hotels Leisure Office etail a patented process blend of NC mineral fiber, organic binders. Pre-finished with primer and top coat paints. Manufactured in water felted mineral fiber technology. Material safety data sheet available on request. Fire eaction BS 476 Pt 6/7 Class 1/0 ASTM E84, Class A Flame spread: 25 Smoke developed: 15 Fire resistance egular BS 476 Pt min. protection to steel beams and timber floor. Humidity esistance Maximum 90% H / 32 C (ClimaPlus) Thermal esistance 0.37 m 2 C/W kg/m 2 (egular) for 3/4" panel Maintenance Easily cleaned using soft brush or vacuum. Pedestal I Plain *Type : : egular ILT 24 x 24 x 3/4 DPIS669 DPIS % D Class E Hz αs αw= 0.15 Pedestals/DONN DX15

14 72 US specialty ceilings DONN grid suspension systems 73 Innovation and quality you can build on US also offers a number of innovative specialty ceiling systems to enhance unique architectural settings. Whether you want a classic sculpted feel, the excitement and drama of a 3-dimensional design, or just plain elegance, US can offer you ceiling solutions to meet the demanding and artistic requirements of contemporary building interiors US is the world s leading manufacturer of ceiling grid, offering the widest range of profiles on the market today. DONN grid from US is compatible with all US ceiling tiles as well as most third party brands. DONN DX from US is the most widely specified grid in Middle East the patented clip design makes it fast and easy to install but also easy to remove without the need for tools. All US DONN grid suspension systems are designed and manufactured to ensure both structural and aesthetic integrity in all ceiling designs. They are certified to meet the most stringent national standards and to comply with all relevant building codes and norms. Strict quality assurance procedures (ISO 9001 : 2008) ensure consistent manufacturing and finished product quality. US s extensive distribution and sales network has been operating for more than 25 years, supplying technical expertise and support to all our customers. You can rest assured that your products will be delivered wherever you need them, on spec and on time. From the product formulation we choose to the processes we employ, we are committed to products that are designed, manufactured, distributed and used in a sustainable way to minimize overall environmental impact.

15 74 Installing a DONN grid system 75 Step 1 Measuring and planning are key first steps in the Step 3 To confirm level, stretch a string until taut along Step 4 ➍ ➋ Step 2 ➊ Steps 5/6 ➌ installation process. Measurement and placement of the tees will be on centre (o.c.), meaning from the centre of one to the centre of the next. Planning starts with a drawing of the room that shows all walls, including bays, alcoves beams and stairwells. Note which direction the joists (if any) are running, or if architectural drawings necessitate working in one direction or another. Determine the lines for main runners and cross tees in such a way that the tiles that about the wall are at least half a tile (300mm). ➊ Main tee 3600/3660mm ➋ Cross Tee 1200/1220mm ➌ Cross Tee 600/610mm the positions which the main tee will occupy. Inserting a nail between the wall and the wall angle at marked locations serves as a good anchor for this purpose. Stretch another string across the room where the first row of cross tees will be located. This identifies where the first prepunched slots need to fall. Check to be sure the cross tee string is at 90 to the main tee string via the method. Install the hangers at 1200mm o.c. above the lines of the main runners. Fix to the structure above using appropriate plugs, screws or other devices. Step 4 Attach the main runners to the hangers. In each row, trim the main tee so that the cross-tee slot will line up with the cross-tee string. Mount main tees, resting the cut end of the main tee on the wall angle. The cut end of the main runner should be about 5mm away from the wall. Step 7 emoval as easy as installation. Just grasp the main tee with one thumb under the main tee-cross tee connection and, pushing up with the thumb, give the main tee a quick, short twist. That s all it takes no tools needed. The strong clip means that the grid can be reinstalled straightaway with no tearing or bending of the clip. ➊ Main Tee 3600/3660mm ➋ Cross Tee 1200/1220mm ➌ Cross Tee 600/610mm ➍ Hanger The appearance of a suspended acoustical ceiling is dependent both on the materials used and on the quality of the installation. US manufactures components to meet BS8290 & BS EN 13964, assuring that the material, structural and quality standards are as prescribed. Installation must meet BS8290, assuring proper level and secure attachment as prescribed.ood construction conditions are very important when successfully installing a suspended ceiling. It is recommended that the temperature and humidity range be C and max. 75% relative humidity. Store materials in a protected area, store tiles on the job at least 3 days prior to installation. Step 2 Mark the desired ceiling height (maintaining at least 70mm clearance below the lowest duct, pipe or beam.) Measure and mark the walls at all corners above the installation level (= add the height of the wall angle to the desired ceiling height.) Snap a chalk line and test for level. Measuring down from joists or up from the floor is not recommended, since neither may be level. Install wall angle with top edge of angle at the chalk line, spacing appropriate fixings 450mm o.c. or closer. Cut and mitre outside and inside angles at 45, fitting them snugly together. Alternatively, simply butt angles at corner (as in system illustration). Step 5 Install cross tees, assuring that they are adequately connected to main tees (they click in place when properly seated). Where two cross tees intersect in the same slot, insert second cross-tee end to the left of the first. Where a cross-tee is installed without an opposing cross-tee, a nail should be slipped into the opening of the cross-tee clip to maintain the pull-out value for the cross-tee. Step 8 Main tee demounting Using a straight shearing motion, push with your left hand and pull with your right hand to disconnect the main runner splice. Note: do not twist the splice during the removal procedure Other installation tips A Cut tees with aviation snips, first the stem and then the flanges. B Cut mineral fibre panels with utility knife and straight edge, cutting the face first. Cut panels should be at least 15mm larger than the opening. max. 450mm x Hanger positions Step 6 Lay in panels, beginning at one corner and completing row by row. Tilt each panel up through the opening and lower it to rest squarely on all four tees. C To install panels around obstructions, draw their exact locations on the panels and cut out. Then cut the panel in two parts through the largest section of the cut-out to enable fitting. D To trim for Shadowline edge, use a utility knife to cut the panel, first at the face, then from the edge, to the same depth as Shadowline. If windows, stairwells, etc., extend above the ceiling plane, build suitable valances and attach wall angle.

16 76 DONN DX24 Intermidiate Duty 77 Main unner DX3600IM Tile edge supported DX 24 / Suspension wire - DSW2 DX24 / Angle section - DA5 Long Cross Tee DX1200LM DX24 / SLT DX24 / Cross section Main tee and cross tee connection. DX24 / SLB Materials All US suspension systems feature a body and cap made of hot-dip galvanized steel. To ensure that the cap remains attractive and rust-free for long term, manufacturing includes an exclusive four-step coating process that outperforms the competition in paint adhesion and corrosion resistance, as proven by industry-standard salt spray tests conducted by an independant laboratory. For our extreme environments we offer our grid system, with hot-dipped galvanized steel body and painted aluminum cap for additional corrosion and humidity resistance. Product Information Nr Item reference Metric Imperial ➊ Main unner DX3600IM DX3660IM ➋ Long Cross Tee DX1200LM DX1220LM ➌ Short Cross Tee DX600LM DX610LM ➍ Wall Angle MT3600-MS3600 ➎ Hanger DSW2 ef. Distance (mm) A max B 1200 C max. 400 D 600 Quantity Linear meter requierd per square meter For construction layouts use the following formulas to calculate linear meters (LM) per square meter (m 2 ) Main tee (1/ Main Tee centres) eg. if MT at 1200mm centres 1 =0.83LM/m Cross tee (1/ Cross Tee centres) eg. if CT at 600mm centres 1 =1.67LM/m Note: These calculations do not allow for wastage, damage or irregularities but are intended as an informative guideline to assist with the calculation of product required for a given area ( in m 2 ) System characteristics: Exposed 24mm system The most widely used grid system in the world Safe, fast and simple to install & easily accessible Maximum economy and design simplicity Cross-tees with override-ends resist twisting and give professionnally finished look with no exposed steel edges Patented QUICK-ELEASE TM clip design: demountable without tools Compatible with square edge and SLB edge ceiling tiles Audible Click means you know when tees are connected Exceed load compliance specifications as per ASTM C 635 Available in metric and imperial sizes Short Cross Tee DX600LM Maximum allowed weight of tiles per m 2 of ceiling Main runner at 1200mm Module Main runner at 600mm Hanger distance (mm) 600 x x x x Note: The load per m 2 must be distributed uniformly (no point loads) over the ceiling area. After loading, the deflection of any grid component will remain within the maximum deflection per span as stated in BS: 8290: 1991, provided the grid layout is as presented in the sketch. Please consult US for other layouts, load or hanger distance. Specification DONN DX24-IM rid shall be DONN DX24 exposed grid system, hot dipped galvanised steel ' T ' section with pre-painted capping. Table width 24mm. To suit variable module sizes, most typically 600 x 600mm and 1200 x 600mm. Main runners: 33 x 24mm, ref DX3600IM shall be normally spaced at 1200mm centres and suspended from the structure or soffit using pre-straightened 2mm diameter HD steel wire hangers, ref DSW2, at typically 1200mm centres. First hanger shall be no more than 450mm from the perimeter. Main runners joined end on by means of the integral splice. Splice connections shall be supported within 150mm with a hanger, and shall be staggered across the ceiling area. Cross tees: 1200mm cross tees, 25 x 24mm ref DX1200LM, shall be installed perpendicular between the main runners at 600mm centres to form a 1200 x 600mm module. If applicable, 600mm cross tees, 25 x 24mm ref DX600LM, shall be installed perpendicular between the 1200mm cross tees to form a 600 x 600mm module. All cross tees feature a joggled end detail. Perimeter trims: 22mm x 19.5mm /19 x 9 x 9 x 19mm painted HD steel angle trim, ref MT3600/MS3600, fixed to perimeter wall using fixings appropriate to the structure at maximum 450mm centres. Corners shall normally be finished with a lapped or butt joint. Clip to Clip Security Clip to Clip Connection DX24 / revoe clip Partition head fixing using revoe clips with DX24. Spring clip Spring clip application. Hangers: Shall be from pre straightened 2mm diameter HD steel wire, ref DSW2. Hangers shall be fixed through holes in stalk or bulb of main runner and wrapped around itself a minimum of 3 times. Alternatively, hangers can be formed from 25 x 25mm HD steel angle section, ref DA5, fixed to main runners using appropriate self drilling screws or nut and bolt fixings. Hangers shall be normally spaced at 1200mm centres although alternative spacings are acceptable provided maximum loadings stated above are not exceeded. Hangers to be fixed to structure or soffit using fixings appropriate to the structure or soffit. Hold down clips: Where applicable, these shall be non removable type clips, ref VB45. These generally will only be required in certain fire protecting assemblies or where there is a risk of tile uplift. Where fitted, these should be applied to all grid members at a rate of 1 clip per 600mm of tile edge.

17 78 DONN DX24 Heavy Duty - Standard 79 Main unner DX3600H Tile edge supported DX24 / SLT DX24 / DX24 / SLB DX24 / Suspension wire - DSW2 DX24 / Angle section - DA5 Long Cross Tee DX1200H30 / DX1200LM Cross section Main tee and cross tee connection. ef. Distance (mm) A max B 1200 C max. 400 D 600 Quantity Linear meter requierd per square meter For construction layouts use the following formulas to calculate linear meters (LM) per square meter (m 2 ) Main tee (1/ Main Tee centres) 1 eg. if MT at 1200mm centres =0.83LM/m Cross tee (1/ Cross Tee centres) 1 eg. if CT at 600mm centres =1.67LM/m Note: These calculations do not allow for wastage, damage or irregularities but are intended as an informative guideline to assist with the calculation of product required for a given area ( in m 2 ) Short Cross Tee DX600H30 / DX 600LM Maximum allowed weight of tiles per m 2 of ceiling Main runner at 1200mm Module Main runner at 600mm Hanger distance (mm) 600 x x x x 1200 DX24 / revoe clip Partition head fixing using revoe clips with DX24. Clip to Clip Security Clip to Clip Connection Spring clip Spring clip application. Materials All US suspension systems feature a body and cap made of hot-dip galvanized steel. To ensure that the cap remains attractive and rust-free for long term, manufacturing includes an exclusive four-step coating process that outperforms the competition in paint adhesion and corrosion resistance, as proven by industry-standard salt spray tests conducted by an independant laboratory. For our extreme environments we offer our grid system, with hot-dipped galvanized steel body and painted aluminum cap for additional corrosion and humidity resistance. Product Information Nr Item reference Metric Imperial ➊ Main unner DX3600H DX3660H30 ➋ Long Cross Tee DX1200H30 / DX1200 LM DX1220H30 / DX 1220LM ➌ Short Cross Tee DX600H30 / DX600LM DX610H30 / DX610LM ➍ Wall Angle MT3600-MS3600 ➎ Hanger DSW2 System characteristics: Exposed 24mm system The most widely used grid system in the world Safe, fast and simple to install & easily accessible Maximum economy and design simplicity Cross-tees with override-ends resist twisting and give professionnally finished look with no exposed steel edges Patented QUICK-ELEASE TM clip design: demountable without tools Compatible with square edge and SLB edge ceiling tiles Audible Click means you know when tees are connected Exceed load compliance specifications as per ASTM C635 Available in metric and imperial size Note: The load per m 2 must be distributed uniformly (no point loads) over the ceiling area. After loading, the deflection of any grid component will remain within the maximum deflection per span as stated in BS: 8290: 1991, provided the grid layout is as presented in the sketch. Please consult US for other layouts, load or hanger distance. Specification DONN DX24-H rid shall be DONN DX24 exposed grid system, hot dipped galvanized steel ' T ' section with pre painted capping. Table width 24mm. To suit variable module sizes, most typically 600 x 600mm and 1200 x 600mm. Main runners: 38 x 24mm, ref DX3600H shall be normally spaced at 1200mm centres and suspended from the structure or soffit using pre-straightened 2mm diameter HD steel wire hangers, ref DSW2, at typically 1200mm centres. First hanger shall be no more than 450mm from the perimeter. Main runners joined end on by means of the integral splice. Splice connections shall be supported within 150mm with a hanger, and shall be staggered across the ceiling area. Cross tees: 1200mm cross tees, 38 x 24mm ref DX 1200H30 and 25 x 24mm ref DX1200LM, shall be installed perpendicular between the main runners at 600 mm centres to form a 1200 x 600mm module. If applicable, 600mm cross tees, 25 x 24mm ref DX600LM and 38 x24mm ref DX600H30, shall be installed perpendicular between the 1200mm cross tees to form a 600 x 600mm module. All cross tees feature a joggled end detail. Perimeter trims: 22mm x 19.5mm/19 x 9 x 9 x19mm painted HD steel angle trim, ref MT3600/MS3600, fixed to perimeter wall using fixings appropriate to the structure at maximum 450mm centres.corners shall normally be finished with a lapped or but joint. Hangers: Shall be from pre straightened 2mm diameter HD steel wire, ref DSW2. Hangers shall be fixed through holes in stalk or bulb of main runner and wrapped around itself a minimum of 3 times. Alternatively, hangers can be formed from 25 x 25mm HD steel angle section, ref DA5, fixed to main runners using appropriate self drilling screws or nut and bolt fixings. Hangers shall be normally spaced at 1200mm centres although alternative spacings are acceptable provided maximum loadings stated above are not exceeded. Hangers to be fixed to structure or soffit using fixings appropriate to the structure or soffit. Hold down clips: Where applicable, these shall be non removable type clips, ref VB45. These generally will only be required in certain fire protecting assemblies or where there is a risk of tile uplift. Where fitted, these should be applied to all grid members at a rate of 1 clip per 600mm of tile edge.

18 80 DONN DXL24 Heavy Duty - Fire ated 81 Main unner DXL3600 Tile edge supported DX24 / DX24 / SLT DX24 / SLB DX24 / Suspension wire - DSW2 DX24/ Angle section - DA5 Long Cross Tee DX1200H30 Cross section Main tee and cross tee connection. ef. Distance (mm) A max B 1200 C max. 400 D 600 Quantity Linear meter requierd per square meter For construction layouts use the following formulas to calculate linear meters (LM) per square meter (m 2 ) Main tee (1/ Main Tee centres) eg. if MT at 1200mm centres 1 =0.83LM/m Cross tee (1/ Cross Tee centres) eg. if CT at 600mm centres 1 =1.67LM/m Note: These calculations do not allow for wastage, damage or irregularities but are intended as an informative guideline to assist with the calculation of product required for a given area ( in m 2 ) Short Cross Tee DX600H30 Maximum allowed weight of tiles per m 2 of ceiling Main runner at 1200mm Module Main runner at 600mm Hanger distance (mm) 600 x x x x Fire protection DX main tees are designed to expand at the fire lance in the event of a fire (shown here). This maintains the structural integrity of the ceiling and holds tiles in place. DX24 / revoe clip Partition head fixing using revoe clips with DX24. Spring clip Spring clip application. Materials All US suspension systems feature a body and cap made of hot-dip galvanized steel. To ensure that the cap remains attractive and rust-free for long term, manufacturing includes an exclusive four-step coating process that outperforms the competition in paint adhesion and corrosion resistance, as proven by industry-standard salt spray tests conducted by an independant laboratory. For our extreme environments we offer our grid system, with hot-dipped galvanized steel body and painted aluminum cap for additional corrosion and humidity resistance. Product Information Nr Item reference Metric Imperial ➊ Main unner DXL3600 DXL3660 ➋ Long Cross Tee DX1200H30 DX1220H30 ➌ Short Cross Tee DX600H30 DX610H30 ➍ Wall Angle MT MS3600 ➎ Hanger DSW2 System characteristics: Exposed 24mm system The most widely used grid system in the world Safe, fast and simple to install and easily accessible Maximum economy and design simplicity Cross-tees with override-ends resist twisting and give professionally finished look with no exposed steel edges Patented QUICK-ELEASE TM clip design Demountable with tools Compatible with Square edge and SLB edge ceiling tiles Designed for fire rated ceilings Audible Click means you know when tees are connected Exceed load compliance specifications as per ASTM C 635 Available in metric and imperial sizes Note: The load per m 2 must be distributed uniformly (no point loads) over the ceiling area. After loading, the deflection of any grid component will remain within the maximum deflection per span as stated in BS: 8290: 1991, provided the grid layout is as presented in the sketch. Please consult US for other layouts, load or hanger distance. Specification DONN DXL24 rid shall be DONN DX24 exposed grid system, hot dipped galvanised steel ' T ' section with pre-painted capping. Table width 24mm. To suit variable module sizes, most typically 600 x 600mm and 1200 x 600mm. Main runners: 38 x 24mm, ref DXL3600 shall be normally spaced at 1200mm centres and suspended from the structure or soffit using pre-straightened 2mm diameter HD steel wire hangers, ref DSW2, at typically 1200mm centres. First hanger shall be no more than 450mm from the perimeter. Main runners joined end on by means of the integral splice. Splice connections shall be supported within 150mm with a hanger, and shall be staggered across the ceiling area. Cross tees: 1200mm cross tees, 38 x 24mm ref DX1200H30, shall be installed perpendicular between the main runners at 600mm centres to form a 1200 x 600mm module. If applicable, 600mm cross tees, 38 x24mm ref DX600H30 shall be installed perpendicular between the 1200mm cross tees to form a 600 x 600mm module. All cross tees feature a joggled end detail. Perimeter trims: 22mm x 19.5mm/19 x 9 x9 x19mm painted HD steel angle trim, ref MT3600/ MS3600, fixed to perimeter wall using fixings appropriate to the structure at maximum 450mm centres. Corners shall normally be finished with a lapped or butt joint. Hangers: Shall be from pre straightened 2mm diameter HD steel wire, ref DSW2. Hangers shall be fixed through holes in stalk or bulb of main runner and wrapped around itself a minimum of 3 times. Alternatively, hangers can be formed from 25 x 25mm HD steel angle section, ref DA5, fixed to main runners using appropriate self drilling screws or nut and bolt fixings. Hangers shall be normally spaced at 1200mm centres although alternative spacings are acceptable provided maximum loadings stated above are not exceeded. Hangers to be fixed to structure or soffit using fixings appropriate to the structure or soffit. Hold down clips: Where applicable, these shall be non removable type clips, ref VB45. These generally will only be required in certain fire protecting assemblies or where there is a risk of tile uplift. Where fitted, these should be applied to all grid members at a rate of 1 clip per 600mm of tile edge.

19 82 DONN DX15 Centricitee 83 Main unner DXT M 3600 mm Tile edge supported 75mm 150mm 150mm 150mm DX15 / Suspension wire - DSW2 DX15 / Angle section - DA5 Long Cross Tee DXT M DX15 / FL DX15 / FLB Cross section (joggled) Main tee and cross tee connection. ef. Distance (mm) A max B 1200 C max. 400 D 600 Quantity Linear meter requierd per square meter For construction layouts use the following formulas to calculate linear meters (LM) per square meter (m 2 ) Main tee (1/ Main Tee centres) eg. if MT at 1200mm centres 1 =0.83LM/m Cross tee (1/ Cross Tee centres) eg. if CT at 600mm centres 1 =1.67LM/m Note: These calculations do not allow for wastage, damage or irregularities but are intended as an informative guideline to assist with the calculation of product required for a given area ( in m 2 ) Short Cross Tee DXT15-600M Maximum allowed weight of tiles per m 2 of ceiling Main runner at 1200mm Module Main runner at 600mm Hanger distance (mm) 600 x x x x Cross section (butt cut) Main tee and cross tee connection. Fire protection DX main tees are designed to expand at the fire lance in the event of a fire (shown here). This maintains the structural integrity of the ceiling and holds tiles in place. Materials All US suspension systems feature a body and cap made of hot-dip galvanized steel. To ensure that the cap remains attractive and rust-free for long term, manufacturing includes an exclusive four-step coating process that outperforms the competition in paint adhesion and corrosion resistance, as proven by industry-standard salt spray tests conducted by an independant laboratory. For our extreme environments we offer our grid system, with hot-dipped galvanized steel body and painted aluminum cap for additional corrosion and humidity resistance. Product Information Nr Item reference Metric Imperial ➊ Main unner DXT M DXT IM ➋ Long Cross Tee DXT M DXT IM ➌ Short Cross Tee DXT15-600M DXT15-610IM ➍ Wall Angle M93600 ➎ Hanger DSW2 System characteristics: Exposed 15mm system Narrow table grid for subtle visual effect Cross-tees with override-ends resist twisting and give professionally finished look with no exposed steel edges Patented QUICK-ELEASE clip design: easy to remove without tools Safe, fast and simple to install and easily accessible Standard joggled (overriding) cross tee system Suitable for FLB edge and most face cut design ceiling tiles Designed for fire rated ceilings Lay-on Cross Tees resist twist and gapping Audible Click means you know when tees are connected Exceed load compliance specifications as per ASTM C635 Available in metric in imperial size Note: The load per m 2 must be distributed uniformly (no point loads) over the ceiling area. After loading, the deflection of any grid component will remain within the maximum deflection per span as stated in BS: 8290: 1991, provided the grid layout is as presented in the sketch. Please consult US for other layouts, load or hanger distance. Specification DONN DX15 rid shall be DONN DX15 exposed grid system, hot dipped galvanised steel ' T ' section with pre painted capping. Table width 15mm. To suit variable module sizes, most typically 600 x 600mm and 1200 x 600mm. Main runners: 38 x 15mm, ref DXT M shall be normally spaced at 1200mm centres and suspended from the structure or soffit using pre-straightened 2mm diameter HD steel wire hangers, ref DSW2, at typically 1200mm centres. First hanger shall be no more than 450mm from the perimeter. Main runners joined end on by means of the integral splice. Splice connections shall be supported within 150mm with a hanger, and shall be staggered across the ceiling area. Cross tees: 1200mm cross tees, 38x15mm ref DXT M, shall be installed perpendicular between the main runners at 600mm centres to form a 1200 x 600mm module. If applicable, 600mm cross tees, 38x15mm ref DXT15-600M, shall be installed perpendicular between the 1200mm cross tees to form a 600 x 600mm module. All cross tees feature a joggled end detail. Perimeter trims: 24mmx15mm painted HD steel angle trim, ref M9-3600, fixed to perimeter wall using fixings appropriate to the structure at maximum 450mm centres. Corners shall normally be finished with a lapped or butt joint. Hangers: Shall be from pre straightened 2mm diameter HD steel wire, ref DSW2. Hangers shall be fixed through holes in stalk or bulb of main runner and wrapped around itself a minimum of 3 times. Alternatively, hangers can be formed from 25 x 25mm HD steel angle section, ref DA5, fixed to main runners using appropriate self drilling screws or nut and bolt fixings. Hangers shall be normally spaced at 1200mm centres although alternative spacings are acceptable provided maximum loadings stated above are not exceeded. Hangers to be fixed to structure or soffit using fixings appropriate to the structure or soffit. Hold down clips: Where applicable, these shall be non removable type clips, ref VB45. These generally will only be required in certain fire protecting assemblies or where there is a risk of tile uplift. Where fitted, these should be applied to all grid members at a rate of 1 clip per 600mm of tile edge.

20 84 US Middle East Limited Loadings - DONN DX 24mm Exposed rid Lighting Installation DONN DX 24mm Exposed rid 85 Ceiling Mass - Kg/m 2 Use of Maximum Allowable ross Ceiling Charts: Determine the maximum allowable ceiling weight for the chosen Main Tee and hanger spacings from raph. Determine the maximum allowable ceiling weight for the chosen Cross Tee spacing from table. The maximum allowable gross weight is the lower of the values from step 1 and 2. Note that any heavy lighting, or other mechanical fixtures should be independently supported. Siesmic considerations for in-plane loads may take precedence in determining the required section (refer US epresentative for detalis). NOTES: Values are based on simple span tests in accordance with recognised International Standard ASTM C635. Higher values can often be attained by allowing for the effect of continuous spans, the actual increase being subject to span arrangements. Please contact US Interiors for guidance. For cross-nogged configurations e.g.: where a 1200x600 mm panel runs parallel with the main tee, the spacing values should be used as for 1200x1200mm module. Where main tees are at 1200mm centres, creating a 600x600mm configuration does not significantly increase load carrying limits. Uniform Loads - kg/lm (linear metre) Uniform loads are loads that are transferred evenly along a given tee. The maximum load is the combined load on both sides of the tee. Example: A 1200 x 600 light fitting weighing 12.6 kg applies a load of 3.5 kg/lm ( = 3.6 lm therefore 12.6 kg / 3.6 lm = 3.5 kg/lm) A 1200 x 600 ceiling panel weighing 3.6 kg applies a load of 1 kg /lm The combined load of light and ceiling panel is 4.5 kg/lm. The maximum allowable uniform load is the lesser of either main or cross tee values. DONN DX Component Uniform Load kg/lm Main Tee DX3600H (m)* 16.8 DX3600I (m)* 11.6 Cross Tee DX600L (m) 35.4 DX1200L (m) 16.7 DX1200L (m) 5.9 * Hanger 1.2m centres Point Loads - kg Point loads are loads that transfer to a tee at a single point (or several points) over a very small area. The weakest point is assumed to be mid span. main tees are based on a 1200mm span. The maximum allowable point load is the lesser of either main or cross tee values. Profile DONN DX DONN DX As worldwide leaders in acoustical ceiling systems, US Interior works with the major lighting manufacturers to ensure system compatibility is maintained. The following guidlines are designed to assist in the correct specification and installation of light fittings in US's DONN Exposed rid and acoustical ceiling systems. Luminaire Positioning Typical recessed pan fitting arrangements are shown below. Main Tees at 1200mm centres are shown horizontal, with suspension at 1200mm centres. efer to Loadings (page 64 this brochure) for maximum allowable point loads, uniform loads and gross ceiling loads depending on type of luminaire and DONN grid selected. Where luminaire weight exceeds point or uniform load maximums consider: a) A higher specifications DONN grid option if applicable (refer to Loadings page 64 this brochure to ensure compliance). b) Independent support from structure. c) Additional suspension points as shown below, or similar. DONN rid Profiles When recessed pan fittings use the top of the DONN tee bulb for support, use the same height tee profiles for even support. DONN DX Component Point Load kg Main Tee DX3600H (m)* 7.9 DX3600I (m)* 7.0 Cross Tee DX600L (m) 13.2 DX1200L (m) 7.9 DX1200L (m) 4.1 * Hanger 1.2m centres Side Elevation End Elevation Ceiling panel Mounted Fittings Light fittings mounted through US acoustical ceiling panels shall not rely on the ceiling panel for support. Their weight shall be transferred back to the grid by: a) Simple supports across the back of the ceiling panel. NB: This method will affect the acoustic properties of the ceiling panel b) Simple supports onto the top of the tee bulb. c) An additional rigid panel across the back of the ceiling panel.

ROCKFON SYSTEM ULTRALINE E

ROCKFON SYSTEM ULTRALINE E System description ROCKFON SYSTEM ULTRALINE E Visible grid ceiling system SYSTE F unctional recess allows for the easy integration of partitions, track lighting and signage E15S8 EDGE WAR YEARS IT LIM

More information

Basic Suspension Systems

Basic Suspension Systems CEILING & WALL SYSTEMS Commercial Ceilings and Walls Solutions Guide Installing Armstrong Suspended Ceilings The ceiling system is made up of Armstrong panels which are supported by a suspension system

More information

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number: SECTION 095113 - ACOUSTICAL PANEL CEILINGS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Provisions of the Contract and of the Contract Documents apply to this Section. 1.2 DEFINITIONS A. AC: Articulation

More information

Code Compliance Meets the requirements for suspended ceilings in accordance with the 2012 International Building Code.

Code Compliance Meets the requirements for suspended ceilings in accordance with the 2012 International Building Code. Pei Evaluation Service is an accredited ISO Standard 17065 Product Certifier, accredited by the IAS. This Product Evaluation Report represents a product that Pei ES has Evaluated and this product has a

More information

ROCKFON SYSTEM T24 A/E ECR

ROCKFON SYSTEM T24 A/E ECR System description ROCKFON SYSTEM T24 A/E ECR Enhanced corrosion resistant ceiling systems for humid environments A EDGE C orrosion resistance Class D (EN 13964) YEARS IT LIM ED GRP WAR NT Y E very single

More information

A. This Section includes acoustical panel ceilings installed with exposed suspension systems.

A. This Section includes acoustical panel ceilings installed with exposed suspension systems. SECTION 09511 ACOUSTICAL PANEL CEILINGS PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of Contract, including General and Supplementary Conditions and Division 1 Specification

More information

USG Ceiling Solutions. LOGIX Integrated Ceiling Systems SYSTEMS GUIDE

USG Ceiling Solutions. LOGIX Integrated Ceiling Systems SYSTEMS GUIDE USG Ceiling Solutions LOGIX Integrated Ceiling Systems SYSTEMS GUIDE SYSTEMS GUIDE Logix Brand Integrated Ceiling Systems from USG allow you to design ceilings that meet building requirements without

More information

SECTION GYPSUM BOARD ASSEMBLIES

SECTION GYPSUM BOARD ASSEMBLIES SECTION 09 21 16 GYPSUM BOARD ASSEMBLIES PART 1 GENERAL 1.1 SECTION INCLUDES A. Metal stud wall and ceiling framing, 20 gauge. B. Metal channel suspended ceiling framing. C. Gypsum board. D. Gypsum sheathing.

More information

Gyptone edge D1 system Installation manual

Gyptone edge D1 system Installation manual Installation manual Design and technique Product description Gyptone edge D is a pre-painted, demountable suspended acoustic ceiling, mounted in a concealed grid system (T-). Gyptone ceilings can be used

More information

SECTION ACOUSTICAL PANEL CEILINGS PART 1 - GENERAL

SECTION ACOUSTICAL PANEL CEILINGS PART 1 - GENERAL SECTION 09511 - ACOUSTICAL PANEL CEILINGS PART 1 - GENERAL 1.01 DESCRIPTION: A. Work under this section is subject to requirements of the Contract Documents including the General Conditions and Supplementary

More information

Technical Services Information Bureau

Technical Services Information Bureau Technical Services Information Bureau INSTALLING ACOUSTICAL LAY-IN TYPE CEILINGS IN SEISMIC REGIONS AUGUST 2009 UPDATED MAY 2017 TECHNICAL BULLETIN This document covers the installation practices recognized

More information

CI/SfB (35) Xy [ Between us, ideas become reality. ] September 2005 FLAT. DrywallGridSystem. Technical Guide CURVED

CI/SfB (35) Xy [ Between us, ideas become reality. ] September 2005 FLAT. DrywallGridSystem. Technical Guide CURVED CEILING SYSTEMS CI/SfB (35) Xy [ Between us, ideas become reality. ] September 2005 FLAT Technical Guide CURVED Index Page FEATURES and BENEFITS 1 COMPONENTS 2 Main Runners Cross Tees Perimeter Treatment

More information

Ceiling Systems. Technical Guide

Ceiling Systems. Technical Guide Ceiling Systems Between us, ideas become reality In this booklet (also found on armstrong.com/capz) Pages 2-4 System Layout and Components Pages 5-8 Installation Details Pages 9-16 Configuration Drawings

More information

Metal ceilings. OWAtecta. OWAtecta Why metal ceilings. Planning with OWAtecta Variety formation of the ceiling

Metal ceilings. OWAtecta. OWAtecta Why metal ceilings. Planning with OWAtecta Variety formation of the ceiling Metal ceilings Why metal ceilings Metal ceilings are different. The density of their surface and the aesthetic restraint of their design offer the architect and builder particular creative options and

More information

SECTION GYPSUM BOARD

SECTION GYPSUM BOARD SECTION 09250 GYPSUM BOARD PART 1GENERAL 1.1 SUMMARY A. Related Documents: General and Supplementary Conditions of the Contract, Division 1 - General Requirements, and Drawings are collectively applicable

More information

Suspension Systems for Acoustical Lay-in Ceilings Seismic Design Categories D, E & F

Suspension Systems for Acoustical Lay-in Ceilings Seismic Design Categories D, E & F NWCB Technical Document SUSPENDED CEILINGS 401 Suspension Systems for Acoustical Lay-in Ceilings Seismic Design Categories D, E & F 10/09 This document has been revised based on current Building Code standards.

More information

SECTION ACOUSTICAL PANEL CEILINGS

SECTION ACOUSTICAL PANEL CEILINGS SECTION 095113 ACOUSTICAL PANEL CEILINGS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and General Provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification

More information

system 200/205 modular hook-on tiles (concealed grid) SAS International +44 (0)

system 200/205 modular hook-on tiles (concealed grid) SAS International +44 (0) metal ceilings system 200/205 modular hook-on tiles (concealed grid) SAS International +44 (0) 118 929 0900 www.sasint.co.uk system 200 information System Description SAS System 200 is a range of square,

More information

STANDARD PRODUCTS - CUSTOM LOOK

STANDARD PRODUCTS - CUSTOM LOOK AXIOM ClOUDS STANDARD PRODUCTS - CUSTOM LOOK AXIOM AXIOM can give your next space a unique and crisp feel. The AXIOM family offers dramatic visuals with a variety of flat vertical trims and design profiles.

More information

EXCEL Medical Waste - Equipment Installation Section SECTION GYPSUM BOARD

EXCEL Medical Waste - Equipment Installation Section SECTION GYPSUM BOARD SECTION 09 29 00 GYPSUM BOARD PART 1 - GENERAL 1.1 DESCRIPTION This section specifies installation and finishing of gypsum board. 1.2 RELATED WORK A. Installation of steel framing members for walls, partitions,

More information

FIRE PROTECTION. GTEC Shaftwall systems 244 GTEC Shaftwall Stairwell systems 248 GTEC Horizontal Shaftwall systems 249 GTEC Encasement systems 250

FIRE PROTECTION. GTEC Shaftwall systems 244 GTEC Shaftwall Stairwell systems 248 GTEC Horizontal Shaftwall systems 249 GTEC Encasement systems 250 FIRE PROTECTION GTEC Shaftwall range uses a specially designed system to protect voids and shafts in buildings. It resists pressure changes and enables installation from one side of the shaft only. GTEC

More information

METALWORKS Blades Classics

METALWORKS Blades Classics METALWORKS Blades Classics Assembly and Installation Instructions Sold by the: Pcs/Ctn METALWORKS BLADES CLASSICS ITEMS: Item # Item Name Incl with Blades Classics 8155 22.5 x 4 x 1" with two factory installed

More information

SIMEILINGS TORSION SPRING CEILING SYSTEM SPECIFICATION

SIMEILINGS TORSION SPRING CEILING SYSTEM SPECIFICATION TORSION SPRING CEILING SYSTEM SPECIFICATION NOTICE: Consult your local Sound Concepts representative or contact Sound Concepts at 204.783.6297 before specifying any optional or custom element as shape,

More information

ECONO 200 INPLANT OFFICE

ECONO 200 INPLANT OFFICE Warehouse Storage & Material Handling Equipment+ ECONO 200 INPLANT OFFICE INSTALLATION & ASSEMBLY INSTRUCTIONS American Surplus Inc. 1 Noyes Ave. East Providence, RI Phone: (800) 989-7176 Fax: (401) 434-7414

More information

STEEL STUD, TRIMS AND ACCESSORIES FOR DRYWALL CONSTRUCTION MONTREAL TORONTO CALGARY EDMONTON VANCOUVER THE STRENGTH WITHIN

STEEL STUD, TRIMS AND ACCESSORIES FOR DRYWALL CONSTRUCTION MONTREAL TORONTO CALGARY EDMONTON VANCOUVER THE STRENGTH WITHIN STEEL STUD, TRIMS AND ACCESSORIES FOR DRYWALL CONSTRUCTION MONTREAL TORONTO CALGARY EDMONTON VANCOUVER THE STRENGTH WITHIN STEEL STUD AND TRACK FOR DRYWALL PARTITIONS TAKE ADVANTAGE OF THE SAVINGS IN TIME

More information

Section SoundPly LR M25 Acoustic Ceiling Panels

Section SoundPly LR M25 Acoustic Ceiling Panels Section 095126 Acoustic Ceiling Panels PART 1 GENERAL 1.1 RELATED DOCUMENTS 1.2 SUMMARY A. Drawings and general conditions of the Contract, including General and Supplementary Conditions and Division 1

More information

Suspension System Data Center Ceiling Solutions

Suspension System Data Center Ceiling Solutions Hardware That Needs to be Purchased Separately Screws are fine listed as shown: Min 1-1/4" or longer #8 Truss head self-tapping screws for attaching structural wall angle, lateral support bar 16" or 4"

More information

Gold Bond BRAND Gypsum Sheathing

Gold Bond BRAND Gypsum Sheathing BRAND 09 06 29 16 00/NGC 43/NGC brand is a moisture-resistant sheathing installed on the outside of exterior framing as a substrate for exterior claddings. It is manufactured with a treated water-resistant

More information

1. Interior gypsum wallboard. 2. Exterior gypsum board panels for ceilings and soffits. 3. Tile backing panels.

1. Interior gypsum wallboard. 2. Exterior gypsum board panels for ceilings and soffits. 3. Tile backing panels. SECTION 09260 - GYPSUM BOARD ASSEMBLIES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 1 Specification

More information

I-STUD Shaftwall System

I-STUD Shaftwall System I-STUD Shaftwall System Summit Tower I-Stud and CertainTeed Shaftliner TM MILL CERTIFIED Steel-Con 00% GALVANIZED Steel Construction Systems UL Evaluation Report No. ER3660-02 Intertek The I-Stud is approved

More information

A. This Section includes ceilings consisting of acoustical panels and exposed suspension systems.

A. This Section includes ceilings consisting of acoustical panels and exposed suspension systems. SECTION 09 51 13 PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply

More information

GLASS WALL SPECIFICATIONS

GLASS WALL SPECIFICATIONS GLASS WALL SPECIFICATIONS Series GA1 Ultra Acoustical, STC 45/46, Omni, Glass Wall PRODUCT OVERVIEW: Top Supported Side Stack Individual, Omni-Directional s Manually Operated Maximum Opening Height: 12'

More information

Anchor bolts ASTM F1554, Gr. 36 Wide flange beams ASTM A992, Fy = 50 ksi Misc. structural steel ASTM A36, Fy = 36 ksi

Anchor bolts ASTM F1554, Gr. 36 Wide flange beams ASTM A992, Fy = 50 ksi Misc. structural steel ASTM A36, Fy = 36 ksi STRUCTURAL NOTES MATERIAL STRENGTHS Structural Steel Reinforcing Steel Concrete Masonry Structural Lumber Anchor bolts ASTM F1554, Gr. 36 Wide flange beams ASTM A992, Fy = 50 ksi Misc. structural steel

More information

The GlasRoc Shaftliner Type X advantage...

The GlasRoc Shaftliner Type X advantage... C e r t a i n T e e d SHAFTLINER F o r A r e a S e p a r a t i o n F i r e w a l l s Shaftliner S Type X for Area Separation GlasRoc Shaftliner is a specially formulated product for applications where

More information

Model 4010 Individual Panels / Curve & Diverter

Model 4010 Individual Panels / Curve & Diverter Model 4010 Individual Panels / Curve & Diverter Introduction: The following three (3) part specification offers the Standard and Optional features for the Model 4010 Curve & Diverter Operable Wall System.

More information

where high efficiency is the standard

where high efficiency is the standard Access Doors 2016 where high efficiency is the standard Experience Milcor offers years of experience in the manufacture of a broad range of products and services for residential, commercial, institutional

More information

COOK COUNTY ILLINOIS CONTRACT FOR WORK DOCUMENT NO Countywide Warehouse and Records Storage Center Hawthorne Project TKB No.

COOK COUNTY ILLINOIS CONTRACT FOR WORK DOCUMENT NO Countywide Warehouse and Records Storage Center Hawthorne Project TKB No. SECTION 092900 GYPSUM BOARD PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

Union County Vocational - Technical Schools Scotch Plains, New Jersey

Union County Vocational - Technical Schools Scotch Plains, New Jersey SECTION 092500 - GYPSUM BOARD PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections,

More information

Endure 900 Suspended Ceiling Installation Guide

Endure 900 Suspended Ceiling Installation Guide Endure 900 Suspended Ceiling Installation Guide World Commerce Center 2000 Ring Way Road, St. Augustine, FL 32092 Phone: 800-227-8566 or 904-584-1400 www.rulonco.com Receipt and Storage: a. All material

More information

AND ACCESSORIES FOR DRYWALL CONSTRUCTION

AND ACCESSORIES FOR DRYWALL CONSTRUCTION STEEL TRIMS AND ACCESSORIES FOR DRYWALL CONSTRUCTION Quality in your corner. THE STRENGTH WITHIN MONTREAL TORONTO CALGARY EDMONTON VANCOUVER STEEL TRIMS AND ACCESSORIES for Construction BAILEY HAS YOUR

More information

Ecophon Focus E. Connect grid and accessories. The grid is manufactured from galvanized steel.

Ecophon Focus E. Connect grid and accessories. The grid is manufactured from galvanized steel. Ecophon Focus E For applications where an attractive suspended ceiling is required and easy removal of individual tiles is essential. Ecophon Focus E has a recessed visible grid and a tegular edge design,

More information

METHOD STATEMENT FOR Dry Ceiling With Resilient Hanger

METHOD STATEMENT FOR Dry Ceiling With Resilient Hanger METHOD STATEMENT FOR Dry Ceiling With Resilient Hanger Revisions Details: Rev. Date of Issue Prepared 0 6/15/2011 AH Engineering Manager Reviewed QA/QC Manager Approved Project Director Description Originator:

More information

CEILING & WALL SYSTEMS

CEILING & WALL SYSTEMS CEILING & WALL SYSTEMS Axiom Perimeter Trim Commercial Ceilings and Walls Solutions Guide Axiom Perimeter Trim AXIOM Trim The Axiom family of products provide functional and visual options in ceiling design.

More information

The better way to build TM. Installation Manual FOUNDATION SIPs & FROST WALLS SIPs

The better way to build TM. Installation Manual FOUNDATION SIPs & FROST WALLS SIPs The better way to build TM Installation Manual FOUNDATION SIPs & FROST WALLS SIPs November 2016 PWF FOUNDATION & FROST WALL SIPs Installation Manual Table of Contents Topics General Requirements....................................

More information

Com-Tray. Under Floor

Com-Tray. Under Floor Com-Tray Chalfant, a leading supplier of cable trays and systems for utilities, industrial plants, and commercial service, offers Com-Tray, a unique modular, cost-saving system for routing and protecting

More information

SECTION HANGERS AND SUPPORTS FOR ELECTRICAL SYSTEMS

SECTION HANGERS AND SUPPORTS FOR ELECTRICAL SYSTEMS SECTION 26 05 29 HANGERS AND SUPPORTS FOR ELECTRICAL SYSTEMS PART 1 GENERAL 1.1 DESCRIPTION A. Scope: 1. CONTRACTOR shall provide all labor, materials, equipment, and incidentals as shown, specified, and

More information

Shaftwall & Stairwell Systems Fire protection & sound isolation for shafts & stairwells

Shaftwall & Stairwell Systems Fire protection & sound isolation for shafts & stairwells Shaftwall & Stairwell Systems Fire protection & sound isolation f shafts & stairwells what the job demands Shaftwall & Stairwell Systems Fire protection & sound isolation systems f elevat shafts, stairwells

More information

SHORTSPAN. Features. Components

SHORTSPAN. Features. Components Armstrong DGS ShortSpan is a fast and easy solution for framing short spans and an economical alternative to TCR and Furring Channel constructions. Features ShortSpan enables framing without suspension

More information

SECTION PLATE CONNECTED WOOD TRUSSES

SECTION PLATE CONNECTED WOOD TRUSSES SECTION 06173 PLATE CONNECTED WOOD TRUSSES PART 1 GENERAL 1.01 SUMMARY A. Section Includes: 1. Shop fabricated wood trusses for roof and floor framing. 2. Bridging, bracing, and anchorage. B. Related Sections:

More information

HILLSBOROUGH TOWNSHIP CODE ENFORCEMENT

HILLSBOROUGH TOWNSHIP CODE ENFORCEMENT HILLSBOROUGH TOWNSHIP CODE ENFORCEMENT SAMPLE GUIDE FOR RESIDENTIAL DECKS revised 7 16 Call before you dig! 1 800 272 1000 New Jersey One Call. Utility Mark Out. THIS GENERIC GUIDE IS NOT ALL INCLUSIVE

More information

S T R E T C H M E T A L

S T R E T C H M E T A L S T R E T C H M E T A L www.luxalon.com Ceiling Systems Luxalon Stretch metal Striking visual effects Luxalon Stretch Metal offers architects contemporary design freedom. With these versatile materials

More information

2000 POCKET DOOR TECHNICAL DATA

2000 POCKET DOOR TECHNICAL DATA 2000 POCKET DOOR TECHNICAL DATA KWIK-WALL... One Source for Wall Systems. KWIK-WALL s s for the 2000 Series - Steel Panel operable wall systems answer the challenge for space division needs posed by multi-purpose

More information

NATIONAL GYPSUM COMPANY Wood Frame Walls And Ceilings Single- And Double-Layer Construction

NATIONAL GYPSUM COMPANY Wood Frame Walls And Ceilings Single- And Double-Layer Construction Walls And Ceilings Single- And Double-Layer Construction 09 9 00/NGC Single-Layer Construction The single-layer construction system consists of a single layer of Gold Bond brand Gypsum Board applied to

More information

CONCRETE STEPS, HANDRAILS, AND SAFETY RAIL

CONCRETE STEPS, HANDRAILS, AND SAFETY RAIL SUDAS Standard Specifications Division 9 - Site Work and Landscaping Section 9080 - Concrete Steps, Handrails, and Safety Rail CONCRETE STEPS, HANDRAILS, AND SAFETY RAIL PART - GENERAL.0 SECTION INCLUDES

More information

Optima Vector Plank. Installation Instructions. Ceiling

Optima Vector Plank. Installation Instructions. Ceiling Ceiling Systems Between us, ideas become reality Optima Vector Plank Installation Instructions 1. GENERAL 1.1. Product Description The Vector products referenced in these instructions are made from fiberglass.

More information

About Everite and Nutec 2. Nutec Suspended Ceiling Board Features 4. Safety, Handling and Storage 5. General Design Criteria 6

About Everite and Nutec 2. Nutec Suspended Ceiling Board Features 4. Safety, Handling and Storage 5. General Design Criteria 6 c o n t e n t s About Everite and Nutec 2 Nutec Suspended Ceiling Board Features 4 Safety, Handling and Storage 5 General Design Criteria 6 Nutec Suspended Ceiling Board Product Range 7 Nutec Suspended

More information

MODEL KWIK-WALL... One Source for Wall Systems. SOUND CONTROL

MODEL KWIK-WALL... One Source for Wall Systems. SOUND CONTROL MODEL 2020 KWIK-WALL... One Source for Wall Systems. KWIK-WALL s 2000 Series - Steel Reinforced Panel operable wall systems answer the challenge for space division needs posed by multi-purpose room layouts.

More information

Visit for REVIT, CSI AND CAD data.

Visit  for REVIT, CSI AND CAD data. Visit www.architecturalsurfaces.net for REVIT, CSI AND CAD data. With Architectural Surfaces, Inc., you can easily introduce the charm and classic beauty of real wood. For your next project, choose from

More information

RAISED ACCESS FLOOR SYSTEM TECHNICAL SPECIFICATION

RAISED ACCESS FLOOR SYSTEM TECHNICAL SPECIFICATION RAISED ACCESS FLOOR SYSTEM TECHNICAL SPECIFICATION PROVISIONAL BILL OF QUANTITIES RAISED ACCESS FLOOR SYSTEM TECHNICAL SPECIFICATION 1 RAISED ACCESS FLOOR SPECIFICATION SYSTEM DESCRIPTION This specification

More information

GypLyner UNIVERSAL Metal framed wall lining system

GypLyner UNIVERSAL Metal framed wall lining system Metal framed wall lining system Pizza Express, York 30 Metal framed wall lining system wall lining system is a cost-effective, virtually independent metal frame drylining. It is a general purpose system

More information

Nouvelles Cliniques Nantaises, France, Visona Tangent Architect: A.I.A Architectes ingenieurs associes

Nouvelles Cliniques Nantaises, France, Visona Tangent Architect: A.I.A Architectes ingenieurs associes Nouvelles Cliniques Nantaises, France, Visona Tangent Architect: A.I.A Architectes ingenieurs associes VISONA VISONA DEMOUNTABLE T-GRID CEILING Flexible acoustic ceiling solution with Drag n Drop function

More information

SYSTEM S7-RHOMBOS INSTALLATION MANUAL

SYSTEM S7-RHOMBOS INSTALLATION MANUAL SYSTEM S7-RHOMBOS INSTALLATION MANUAL GENERAL INFORMATION GENERAL INFORMATION This assembly manual addresses all metal ceilings manufactured by durlum. The different sections describe the related/relevant

More information

ARCHITECTURAL CEILING HANGERS

ARCHITECTURAL CEILING HANGERS , Inc. Manufacturers of Vibration Control Products 350 Rabro Drive 2101 W. Crescent Ave., Suite D Hauppauge, NY 11788 Anaheim, CA 92801 631/348-0282 714/535-2727 FAX 631/348-0279 FAX 714/535-5738 Info@Mason-Ind.com

More information

OPTIMA Vector ULTIMA Vector

OPTIMA Vector ULTIMA Vector OPTIMA ULTIMA Assembly and Installation Instructions CEILING PANEL ITEMS: OPTIMA: 3900, 3900PB, 3901, 3902, 3903, 3904, 3905, 3906, 3907, 3908, 3908PB, 3909 ULTIMA: 1920, 1921 ULTIMA Create! : Z1920UC1

More information

QUICK-LOCK QUICK-LOCK. A complete survey of all Quick-Lock ceiling systems. QUICK-LOCK Ceiling systems. QUICK-LOCK Cross-Lock.

QUICK-LOCK QUICK-LOCK. A complete survey of all Quick-Lock ceiling systems. QUICK-LOCK Ceiling systems. QUICK-LOCK Cross-Lock. A complete survey of all Quick-Lock ceiling systems QUICK-LOCK Ceiling systems QUICK-LOCK Cross-Lock QUICK-LOCK Omega QUICK-LOCK Insula QUICK-LOCK The best base for your ceiling. Unique systems The Quick-Lock

More information

CI/SfB V. Fellert Spray Applied Acoustic Plastering System. Highly absorbent plaster to improve sound surroundings

CI/SfB V. Fellert Spray Applied Acoustic Plastering System. Highly absorbent plaster to improve sound surroundings Uniclass L55:N373 CI/SfB (4-) V EPIC E23:Y45 (P3) Fellert Spray Applied Acoustic Plastering System Highly absorbent plaster to improve sound surroundings High Performance Sound Absorption can be provided

More information

GLASS WALL SPECIFICATIONS

GLASS WALL SPECIFICATIONS GLASS WALL SPECIFICATIONS Series GA2 Ultra Acoustical, STC 45/46 Paired, Glass Wall PRODUCT OVERVIEW: Top Supported Center Stack Paired s Manually Operated Maximum Opening Height: 12' 2 [3.7m] Maximum

More information

GYPSUM BOARD SECTION GYPSUM BOARD PART 1 - GENERAL

GYPSUM BOARD SECTION GYPSUM BOARD PART 1 - GENERAL 13686.00 GYPSUM BOARD 092116-1 1.1 RELATED DOCUMENTS: SECTION 092116 - GYPSUM BOARD PART 1 - GENERAL A. Drawings and general provisions of Contract, including General and Supplementary Conditions and Division

More information

CO9. Sound absorbing solutions C09

CO9. Sound absorbing solutions C09 ! This section includes updated information, added since it was first published in December 05. Section Last updated Introduction /0/06 CasoLine mf /05/07 CasoLine curve /05/07 GypLyner universal /05/07

More information

FACT SHEET #2 DECK INFORMATION

FACT SHEET #2 DECK INFORMATION Borough of Doylestown Building and Zoning Department 57 West Court Street, Doylestown, PA 18901 215.345.4140 FACT SHEET #2 DECK INFORMATION BACKGROUND The provisions of the PAUCC. ICC Property Maintenance

More information

Moduline. Acoustic Enclosure System. Rugged Noise Control Structures Using Acoustically Rated & Field Proven Demountable Components

Moduline. Acoustic Enclosure System. Rugged Noise Control Structures Using Acoustically Rated & Field Proven Demountable Components Moduline Acoustic Enclosure System Rugged Noise Control Structures Using Acoustically Rated & Field Proven Demountable Components Lab certified acoustic ratings Broad range of performance levels 63 Hz

More information

SECTION IMPACT RESISTANT WALL PROTECTION

SECTION IMPACT RESISTANT WALL PROTECTION SECTION 10265 PART I - GENERAL 1.01 DESCRIPTION A. Scope: Work under this Section shall include all materials and installation necessary to provide Impact-Resistant Wall Protection including Wall guards,

More information

DIVISION: SPECIALTIES SECTION: DEMOUNTABLE PARTITIONS REPORT HOLDER: KRUEGER INTERNATIONAL, INC.

DIVISION: SPECIALTIES SECTION: DEMOUNTABLE PARTITIONS REPORT HOLDER: KRUEGER INTERNATIONAL, INC. 0 Most Widely Accepted and Trusted ICC ES Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 3505 Issued 04/2017 This report is subject to renewal 04/2018. DIVISION: 10 00 00 SPECIALTIES

More information

Chevy Chase Club June 30, 2008 Bowie Gridley Architects SECTION GYPSUM BOARD SHAFT WALL ASSEMBLIES

Chevy Chase Club June 30, 2008 Bowie Gridley Architects SECTION GYPSUM BOARD SHAFT WALL ASSEMBLIES SECTION 092116.23 - GYPSUM BOARD SHAFT WALL ASSEMBLIES PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division

More information

OPTIMA, ULTIMA, and LYRA Vector

OPTIMA, ULTIMA, and LYRA Vector OPTIMA, ULTIMA, and LYRA Assembly and Installation Instructions CEILING PANEL ITEMS: OPTIMA: 3900, 3900PB, 3901, 3902, 3903, 3904, 3905, 3906, 3907, 3908, 3908PB, 3909 Non-directional ULTIMA: 1920, 1921

More information

Field Connector for simple installation. Floating Perimeter detail. Field Connector. Perimeter & XL Connector

Field Connector for simple installation. Floating Perimeter detail. Field Connector. Perimeter & XL Connector mm M0-.5 Turnbuckle connections to structural steel 30mm Perimeter Extrusion Simple supported 4 screw assembly and vertically supported flanged grid 750 Montevideo Road Tel (40)799-4200 Main Runner with

More information

Nursery Valdahon, France, Belgravia, Globe Architect: JC ADAM Architecte

Nursery Valdahon, France, Belgravia, Globe Architect: JC ADAM Architecte Nursery Valdahon, France, Belgravia, Globe Architect: JC ADAM Architecte BELGRAVIA DID YOU KNOW THAT in nature, when limestone and smoke particles from volcanos come in contact with water, the crystal

More information

OmniFlex 300 Plus Installation Instructions

OmniFlex 300 Plus Installation Instructions OmniFlex 300 Plus Installation Instructions IMPORTANT PortaFab advises a thorough reading of these instructions before beginning installation. INTRODUCTION Instructions should be read thoroughly and cross-referenced

More information

INSTALLATION MANUAL. METAL INSULATED PANELS -ROXUL -Expanded Polystyrene

INSTALLATION MANUAL. METAL INSULATED PANELS -ROXUL -Expanded Polystyrene INSTALLATION MANUAL METAL INSULATED PANELS -ROXUL -Expanded Polystyrene Insulated Metal Panels London Eco-Metal Manufacturing Inc. **Also see Eco-Metal s Handling Manual** These instructions are provided

More information

SECTION GYPSUM BOARD

SECTION GYPSUM BOARD Manufacturer: American Gypsum 3811 Turtle Creek Blvd., Suite 1200 Dallas, Texas 75219 (800) 545-6302 (214) 530-5634 fax www.americangypsum.com GUIDE SPECIFICATION SECTION 09 29 00 This guide specification

More information

S h e l v i n g CANTILEVER S H E L V I N G S Y S T E M S S t o r a g e S o l v e d

S h e l v i n g CANTILEVER S H E L V I N G S Y S T E M S S t o r a g e S o l v e d Shelving CANTILEVER S H E L V I N G S Y S T E M S S t o r a g e S o l v e d DESIGN FEATURES Due to their rugged strength and pleasing aesthetic design, Spacesaver Cantilever Shelving and Library Media

More information

OptimA, Ultima, CALLa, and LYRA Vector

OptimA, Ultima, CALLa, and LYRA Vector OptimA, Ultima, CALLa, and LYRA Vector Assembly and Installation Instructions ceiling panel items: OPTIMA: 3900, 3900PB, 3901, 3902, 3903, 3904, 3905, 3906, 3907, 3908, 3908PB, 3909 Non-directional ULTIMA:

More information

Ecophon Hygiene Meditec A

Ecophon Hygiene Meditec A Ecophon Hygiene Meditec A Ecophon Hygiene Meditec A C1 is a wall to wall, soundabsorbing ceiling system intended for environments where disinfection and/or cleaning is required on a regular basis. This

More information

Ecophon Solo Baffle. straight cut and painted. Ecophon Solo Baffles are easily demountable systems.

Ecophon Solo Baffle. straight cut and painted. Ecophon Solo Baffles are easily demountable systems. Ecophon Solo Baffle Ecophon Solo Baffles are acoustic solutions, primarily when it is not possible to install wall-to-wall ceilings. Baffles are suitable in buildings where the volume should be maintained,

More information

Integrated LIGHTING. Solutions

Integrated LIGHTING. Solutions Integrated LIGHTING Solutions Lighting INTEGRATION Made Easy We understand the pain points of trying to integrate lighting into the ceiling plane, while being able to specify and maintain the crisp, clean

More information

Exterior. Flexible durability

Exterior. Flexible durability Exterior Luxalon Exterior Ceilings by Hunter Douglas in special aluminium alloy attached to rigidly suspended carriers ensure durability and withstand severe conditions. Allowing a wide range of design

More information

Staggered stud acoustic partition system

Staggered stud acoustic partition system C0 Partitions Staggered stud acoustic partition system All our systems are covered by SpecSure when using genuine Gyproc and Isover products is a non-loadbearing stud partition incorporating a single framework

More information

ROOFING APPLICATION STANDARD (TAS) No. 102(A)-95

ROOFING APPLICATION STANDARD (TAS) No. 102(A)-95 ROOFING APPLICATION STANDARD (TAS) No. 102(A)-95 TEST PROCEDURE FOR STATIC UPLIFT RESISTANCE OF MECHANICALLY ATTACHED, CLIPPED, RIGID, ROOF SYSTEMS (For Methods of Mechanical Attachment Excluding Clips,

More information

PV Mounting System 2703 SERIES 200 UL GROUND MOUNT SYSTEM. SnapNrack Residential PV Mounting Systems Code Compliant Installation Manual

PV Mounting System 2703 SERIES 200 UL GROUND MOUNT SYSTEM. SnapNrack Residential PV Mounting Systems Code Compliant Installation Manual PV Mounting System 2703 SERIES 200 UL GROUND MOUNT SYSTEM SnapNrack Residential PV Mounting Systems Code Compliant Installation Manual Series 200 UL Introduction Series 200 UL Introduction SnapNrack Series

More information

The Ashland Project. Total Area: 1,778 Sq.Ft. 3 Bedroom, 2 Bath, 2 Car Garage

The Ashland Project. Total Area: 1,778 Sq.Ft. 3 Bedroom, 2 Bath, 2 Car Garage The Ashland Project Total Area: 1,778 Sq.Ft. 3 Bedroom, 2 Bath, 2 Car Garage The garage and bedroom extend from the front of this three bedroom home, drawing you visually into the entryway. Brick and stucco

More information

APPLICATION AND FINISHING OF GYPSUM PANEL PRODUCTS

APPLICATION AND FINISHING OF GYPSUM PANEL PRODUCTS GYPSUM ASSOCIATION SPECIFICATIONSI I 6525 Belcrest Road, Suite 480, Hyattsville MD 20782 APPLICATION AND FINISHING OF GYPSUM PANEL PRODUCTS GA-216-2013 This document may be revised or withdrawn from circulation

More information

Optima Vector Ultima Vector

Optima Vector Ultima Vector CEILING&WALL SYSTEMS Between us, ideas become reality Optima Ultima Installation Instructions ceiling panel items: OPTIMA: 3900, 3901, 3902, 3903, 3904, 3905, 3906, 3907, 3908, 3909 ULTIMA: 1920, 1921

More information

Section SECTIONAL INSULATED STEEL DOORS

Section SECTIONAL INSULATED STEEL DOORS 1 GENERAL 1.1 GENERAL REQUIREMENTS General Conditions and Division 01 apply to this section. 1.2 RELATED WORK Section 05500: Miscellaneous Metal Fabrication Section 07900: Joint Sealers Section 09900:

More information

FORMDECK. constructions. constructions

FORMDECK. constructions. constructions FORMDECK constructions constructions Introduction Formdeck300 (FD300) is a very efficient and durable permanent metal tray formwork, reinforcement and ceiling system used for suspended concrete slab construction.

More information

SPECIFICATION FOR REINFORCED SOIL WALL

SPECIFICATION FOR REINFORCED SOIL WALL SPECIFICATION FOR REINFORCED SOIL WALL 1.0 EXTENT OF WORK The work shall consist of Reinforced Soil walls built in accordance with this specification and in conformity with the lines, levels and details

More information

Assemblies Evaluated For 1. Non Axial Load Bearing Wall 2. Transverse Load Capacity 3. Fire Resistance 4. Abuse Resistance

Assemblies Evaluated For 1. Non Axial Load Bearing Wall 2. Transverse Load Capacity 3. Fire Resistance 4. Abuse Resistance Pei Evaluation Service is an accredited ISO Standard 17065 Product Certifier, accredited by the IAS. This Assembly Evaluation Report represents a product that Pei ES has Evaluated. This Assembly Evaluation

More information

Acousti-Seal Encore Paired Panel (10650) Operable Partitions

Acousti-Seal Encore Paired Panel (10650) Operable Partitions Acousti-Seal Encore Paired Panel 10 22 26 (10650) Operable Partitions Optimal choice for straight-line openings that do not require multiple locations or offset storage Panels are hinged together in groups

More information

1 Exam Prep Placing Reinforcing Bars Tabs and Highlights

1 Exam Prep Placing Reinforcing Bars Tabs and Highlights 1 Exam Prep Placing Reinforcing Bars Tabs and s These 1 Exam Prep Tabs are based on the CRSI Placing Reinforcing Bars Recommended Practices, 9 th Edition. Each 1 Exam Prep tabs sheet has five rows of tabs.

More information

SPECIFICATIONS FOR AluSystems Aluminum Composite Panels Series 20 Dry Joint 1.00 GENERAL 1.01 RANGE OF WORK Section includes: Laminated panels and attachment systems for use as exterior cladding. A. Provide

More information

PLANK METAL CEILING SYSTEMS

PLANK METAL CEILING SYSTEMS PLANK METAL CEILING SYSTEMS INTEGRA TILE INTEGRA PLANK INTEGRA OPEN CELL INTEGRA EXPANDED INTEGRA SPECIALS CLIP-IN PLANK 07 12 16 20 CLIP-IN HEAVY DUTY CLIP-IN HEAVY DUTY NONIUS CLIP-IN HINGE-DOWN CLIP-IN

More information