SC fire & smoke stop for above suspended ceilings
|
|
- Lydia Vivian Morgan
- 6 years ago
- Views:
Transcription
1 fire & smoke stop for above suspended ceilings.01 Introduction Lamatherm s and CS systems have been developed to provide a simple and easy to install method of sealing the void formed above suspended ceilings. The standard range has been optimized to include options of materials that are costeffectively matched to suit the specific performance criteria for all suspended ceiling void requirements. Being specifically designed for this application, these products represent a combination of fully qualified performance, practical installation and service benefits. Advantages Up to 5 hours fire resistance Up to R w = 27 db sound reduction These systems comprise a one-piece, close dimensioned product having a precompressed internal mineral fibre core. The products have integral aluminum foil facings to provide a Class O rating and excellent resistance to smoke. A unique method of manufacture (patent protected) provides a resilient lateral compression required to ensure a tight fit. As standard, the materials are supplied with an interlocking overlap joint to further enhance the integrity of the installation. The materials are either supplied as pre-cut units to suit a quoted void size or in sheet form for cutting on site and are installed with no fixing sub-frame being required. -CB Cavity Barrier systems are used to subdivide uninterrupted voids in accordance with Building Regulations. Figure 1. installed within a suspended ceiling system -FS Fire Stop systems maintain continuity of fire resistance for installations aligned with fire rated partitions and, thereby, maintain compartmentation. ceilings suspended above stops & smoke Comprehensive range to suit requirements Options to seals voids up to 1175 mm high No requirement for additional sealants or adhesives fire A one-piece product No requirement for fixing sub-frame Integral foil smoke barrier 1
2 .02 Application The Lamatherm systems provide a certified resilient seal between the top of a partition, or fire resistant suspended ceiling, and the structural soffit. The choice of material is simply determined by the performance requirement in terms of fire resistance. Typical applications include:- Voids above suspended ceilings Acoustic barriers Areas of difficult access -CB Cavity Barriers have been specifically developed to meet the provisions for cavity barriers as required by current legislation. They are used to laterally subdivide large uninterrupted voids above suspended ceilings of up to 1 metre or less. The vertical seals used to subdivide the ceiling voids should, wherever possible, be placed so as to coincide with the fireresisting partitions in the compartment below the ceiling. This may require location of barriers at less than the maximum 20 Approved Document B to the current Building Regulations stipulates maximum dimensions for concealed spaces so as to limit the spread of unseen fire & smoke. Accordingly, -CB Cavity Barriers are used to form a barrier at maximum 20 metre intervals in all directions - assuming that Class O surfaces are exposed within the cavity. & smoke stops above suspended ceilings metre spacing. Where a compartment has many fire-resisting partitions, it should not be necessary to locate a cavity barrier above every one (so long as the maximum limit on void dimension is not exceeded). However, in practice, consideration should be given to the requirement for the -FS Fire Stops are used in this application to continue the line of fire protection. The material is selected to match the rating of the partition and maintain continuity of fire resistance. fire installation of -CB as an acoustic barrier to limit cross-talk. 2
3 .03 Description The materials can be either supplied as precut units to suit a quoted void size or in sheet form for cutting on site. Standard sheet product is supplied 1200 x 1200mm and is complete with edge rebate detail. Supply in sheet form may be of benefit when the actual ceiling void is not known or where it varies significantly. The suspended ceilings fire stops and cavity barriers are single components which are simply engaged end-to-end within the void to form a continuous Fire, Smoke and Acoustic barrier. The correct sized units are placed in position ensuring that the interlocking joints are pushed tightly together..04 Installation For all installations they are fitted to the full depth of the ceiling void with a compression allowance:- For voids up to 200mm high the minimum product height is void height + 5%. For voids mm the minimum product height is void + 10mm. The vertical boards may be finished with foil tape to maintain continuity of the smoke barrier foil facings and enhance the fire and acoustic integrity of the assembly. Further The height of the is sized to suit the measured void height plus a compression allowance For all voids over 200m the system is supplied with a 25mm rebated joint., providing 1175mm cover length For voids under 200mm the CS is supplied with a butt join, providing 1200mm cover length. Joint may be sealed with foil tape to maintain continuity of smoke barrier foil facing fire & smoke stops above suspended ceilings application of tape to the top and along the base of the unit presents an effectively sealed construction which is suitable for plenum lining applications. If necessary the height of the material can be trimmed on site using a sharp serrated knife providing the compression allowance is maintained. 3
4 Fixing brackets are incorporated into the assembly to maintain the integrity of the construction. They are simply impaled alternately into the top and base of the barrier prior to installing, using 3No. per unit which are positioned at nom. 400mm centres. The fixing brackets are mechanically fixed to the surrounding structure with steel fixings. The standard fixing brackets are available in flat pre-notched form for folding on site to the requisite "L" or "Z" shape. They are precut to a spike so that the long leg can penetrate into the barrier. For voids up to 400mm, B15 0 brackets are used. These comprise galvanized mild steel, 150mm x 120mm x 25mm long x 1mm thick. For voids >400mm high, B355 brackets are required which are 355mm x 150mm x 25mm long x 1mm thick and are used with the long leg penetrating into the barrier. * -FS 60 will achieve a fire performance of 90 minutes in tests when used in voids between 200 and 400mm Table number 1: Specification Table Void size mm mm mm mm Fire Rating CS-CB 15 -CB 15 -CB mins 50 mm 50 mm 50 mm No Brkts. 3no. B355 3no. B355 CS-FS 30 -FS 30 -FS 30 -FS 30 HV 30 mins 60 mm 60 mm 60 mm 75 mm No Brkts. 3no. B355 3no. B355 3no. B355 CS-FS 60 -FS 60* - FS 60 - FS 60 HV 60 mins 75 mm 90 mm 90 mm 120 mm No Brkts. 3no. B355 3no. B355 3no. B355 CS-FS 90 -FS mins 90 mm 90 mm No Brkts. 3no. B355 CS-FS180 -FS mins 120 mm 120 mm No Brkts. 3no. B355 CS-FS 300 -FS mins 175 mm 175 mm No Brkts. 3no. B355 3 no. B355 s brackets are required with all installations of. Below 200mm the CS system is used with no bracket requirements. fire & smoke stops above suspended ceilings 4
5 .05 Fire The design and manufacture of the range of LAMATHERM SYSTEMS is based on proven fire performance to BS 476 : Part 20 : Based on multiple tests, each Table number 2: Fire Rating Table material option has been have formally assessed by The Loss Prevention Council to meet the relevant performance rating given in the FIRE RATING TABLE. Verification of fire performance is available upon request. The Loss Prevention Council assessment CC refers. Product Range Size BS 476 Pt 20 System Fire Rating Void Size (mm) Thickness (mm) Cover Integrity Insulation (mm) (mins) (mins) CS-CB15 15 mins Upto CS-FS30 30 mins. Upto CS-FS60 60 mins. Upto CS-FS90 90 mins. Upto CS-FS mins. Upto CS-FS mins. Upto CB15 15 mins CB30 30 mins CB30HV 30 mins FS60 60 mins FS60HV 60 mins FS90 90 mins FS mins FS mins stops above suspended ceilings Lamatherm CB Cavity Barriers Approved Document B to the current Building Regulations requires that cavity barriers must have a minimum standard of fire resistance of 30 minutes with regard to integrity and 15 minutes with regard to In Scotland, Part D4 of the Building Standards (Scotland) Regulations In Northern Ireland, Technical Booklet E, Section 3.27, The Building Regulations (Northern Ireland) In Eire, Technical Guidance Document B, Lamatherm FS fire stops FS60 is suitable for installation above a 60 minute fire rated partition to provide continuity of fire resistance. For more stringent requirements Lamatherm FS Fire stops can provide a fire & smoke insulation. CB15 cavity barriers meets all relevant current provisions for cavity barriers. Section 3.3, The Building Regulations 1991 Specialist Ceilings & Interiors Association (IA), Guide No.1 Good practice for the rating of upto 300 minutes for both insulation and integrity. fire Specifically, these include:- installation of suspended ceilings, Section 6.2. In England and Wales, Approved When a more stringent specification is Document B3 to the Building Regulations required Lamatherm FS Fire stop systems can be used for 30minute cavity barriers. 5
6 .06 Acoustics The and CS range additionally provides a high performance acoustic barrier which improves the room-to-room sound reduction of suspended ceilings. Their acoustic performance is attributable to the mass of the mineral fibre core coupled to the unique resilient lamella board internal construction. Also, the rebated joints, foil facings and the additional sealing of joints with foil tape all serve to provide improved air tightness. Based on laboratory tests to determine airborne sound transmission in accordance with BS EN ISO : 1995, BS 2750 : Part 3 : 1995 on a variety of lamella board constructions, the following Weighted Sound Reduction Index (Rw) values can be used: The installation of the system above a partition will significantly increase the room-to-room attenuation. Typically, the 'cross-talk' via the suspended ceiling void will be improved by db. The precise value will depend upon the Table number 3: Weighted sound reduction index for a selection of systems System Thickness (mm) R W (db) -CB * -FS * CS-FS FS * -FS FS * * = Rw value interpolated from test results. Sound Research Laboratories Limited test report no. : C/99/5L/7743/1 refers. & smoke stops above suspended ceilings specifics of the ceiling construction. Specific advice is available on a project basis. The installation of systems enhances the sound reduction of suspended ceilings which form a continuous This invariably results in improved speech privacy and greater control of disturbance from intrusive noise. fire common void over adjacent areas. 6
7 .07 Service penetrations Fire spread and limitation of damage is principally achieved by compartmentation. These compartments are bounded by fire resistant elements - including Lamatherm Fire Stops. However, in practice, the many services required for buildings use and operation mean that these elements are breached to permit access for services. The gaps around the penetrations must be sealed so that the fire integrity of the Lamatherm have tested the compatibility of their range of fire stopping systems - within the SYSTEMS. Ad-hoc test FC 149 refers. Standard systems can be readily treated to accommodate small to large obstructions such as PVC pipes, cable trays and ductwork. ceilings suspended element is retained. Penetration by cable trays : Permanent Seal Lamatherm FB-FS60 Coated Batt Fire Stops Will maintain integrity of installed systems Carefully cut in aperture to suit. Cut batt to suit. Perimeter of batt / interface with plus perimeter of service penetrations all additionally sealed with: Lamatherm Fire & Acoustic Gap Sealant Penetration by cable trays : Temporary Seal Lamatherm AP-FS120 Adaptable Pillows Cut to suit. Install intumescent pillows Typically used for temporary seals prior to commissioning of systems or whilst in construction or where additional cables will be installed by following trades etc. Penetration by plastic pipes Lamatherm PC-FS120 Intumescent Collars fire & smoke stops above Cut - overize diameter by 10mm max. Position & secure collar with tab fastening. Fix through with metal pin & non-return washer fixings. Make-good with either: Lamatherm Fire & Acoustic Gap Sealant 7
8 Penetration by metal pipes For metal pipes up to 25mm diameter no separate pipe closure system is necessary as the has sufficient material thickness to maintain the seal. If combustible lagging is present on existing pipework, this must be stripped local to the prior to sealing. 'V' notch the so as to tightly receive the pipe diameter. There must be no remaining gaps through the barrier. To ensure the Integrity of the construction, all joints around the perimeter of the pipe must be sealed with : Lamatherm Fire & Acoustic Gap Sealant For metal pipes between mm diameter proprietary closure systems must be used. Please contact the technical helpline. Penetration by fire rated ducts Carefully cut to suit duct perimeter. Apply Lamatherm FM-FS240 Trowel Grade Mastic to duct & mating edge of. Tightly abutt. Additional seal edges with: Lamatherm Fire & Acoustic Gap Sealant It is recommended that all service penetration details are recorded for maintenance purposes as, typically, the company who undertakes the installation may be invited to carryout subsequent alterations as necessary. Specific advice is available on a project basis..08 Technical Specification Form Supplied Colour Gap Size Mineral Fibre foil faced both sides White Tops of walls Within ceiling void 50mm up to 120mm thick 200mm up to 1150mm 50mm up to 1150mm Coating type Density Class O Aluminium Foil Raw material Inaccordance to BS476 80kg/m3 Product supplied 85kg/m3 fire & smoke stops above suspended ceilings Thermal conductivity Fire rating = 0.04 w/mk 60 mins I Insulation 60 mins E Integrity at mean temp. 20 o C Inaccordance to BS476 8
9 .08 Material Safety Data 1. Company Siderise Insulation Limited, Forge Industrial Estate, Maesteg, Bridgend CF34 0AZ. 2. Composition Inert vitreous silicate mineral wool bonded with a thermosetting phenolic resin which has been urea extended. Up to 0.3% of mineral oil. Faced with reinforced aluminum foil on both surfaces. 3. Hazard identification May cause transient skin irritation. High dust levels may irritate the throat. The fibres from which is made are classified as irritant (Xi:R38) under the CHIP Regulations First Aid Measures Eyes: If irritation occurs wash eyes with water. If symptoms persist seek medical advice. Skin: If irritation occurs wash under running water prior to washing with soap and water. 5. Fire Fighting Measures The products are generally non-combustible and do not pose a fire hazard. However, some packaging materials may burn. a] Suitable extinguishing media: water, foam, carbon dioxide or dry powder. b] Unsuitable extinguishing media: none. c] Products of combustion: carbon dioxide, carbon dioxide and some trace gases. d] Observe normal fire fighting procedures. 6. Accidental Release Measures No special measures required. 7. Handling and Storage Avoid unnecessary handling of product. Store in a dry place. 8. Exposure Controls and Personal Protection Maximum Exposure Limit (MEL) 5mg/m 3, 8 hour weighted average. Ensure good general ventilation. Local exhaust ventilation may be required if the method of use produced dust levels in excess of the MEL. Respiratory protection: If the MEL cannot be met, disposable face masks complying with BS/EN149 FFP1 or FFP2 should be used and are suitable for most applications. Hand protection: Not normally required but industrial gloves can be worn. Eye protection: When working with product above head height, eye protection is advised. Skin protection: No special requirement other than loose clothing. 9. Physical and Chemical Properties Appearance: vitreous mineral wool supplied in the form of foil faced strips or foil faced lamella slabs. Melting point above 1000 o C. Solubility: insoluble in water and generally chemically inert. 10. Stability and Reactivity No special physical conditions need to be avoided. No restrictions regarding incompatible materials. Above 230 o C, some binder degradation may occur for a short while, leading to the evolution of small quantities of carbon dioxide, carbon monoxide and other trace gases. 11. Toxicological Effects Human epidemiological studies show no link between exposure to mineral wool fibres and lung disease or any other chronic effects. The base fibres are not classified as a carcinogen by the European Commission Directive 97/69/ EC. 12. Ecological Information Stable product with no known adverse environmental effects. No CFCs or HCFCs are used in the manufacture of the base slab materials. Zero ozone depletion potential. 13. Disposal Considerations No special precautions. Not classified under the Special Waste Regulations Transport Information No special precautions. 15. Regulatory Information No special labeling required. Mineral wool products are not classified under CHIP as hazardous, but are regulated as a man-made mineral fibre (MMMF) under the Control of Substances Hazardous to Health Regulations (COSHH) with a MEL of 5mg/m 3 (gravimetric). This safety data sheet does not constitute an assessment of workplace risk. 16. Other Information Health and Safety Executive Guidance Note EH46 - Manmade Mineral Fibres. Eurisol Health Statement. E.C. Directive 97/69/EC, Note Q. This material safety data does not constitute an assessment of workplace risk. This information reflects typical values and is not a product specification. No warranty expressed or implied is hereby made. Further written information about Lamatherm products can be obtained from the address below. fire & smoke stops above suspended ceilings 9
Safety Data Sheet (SDS) in accordance with REACH Regulation (EC) No 1907/2006. Rockwool Limited, Pencoed, Bridgend, CF35 6NY
1 Product and company identification 1.1 Product name: ROCKWOOL insulation. 1.2 Product use: Thermal insulation, acoustic insulation, fire protection. 1.3 Product appearance: Grey/green colour. Supplied
More informationCERTIFICATE OF APPROVAL No CF 563 SIDERISE INSULATION LIMITED
CERTIFICATE OF APPROVAL No CF 563 1 This is to certify that, in accordance with TS00 General Requirements for Certification of Fire Protection Products The undermentioned products of Forge Industrial Estate,
More informationAquaroc Fibre Cement Board
Fibre Cement Fibre Cement Description Characteristics is an asbestos-free, cellulose fibre reinforced cement board that is very dense with a non-porous surface. The excellent moisture resistant characteristics
More informationSEPTEMBER construction type cavity barriers. SP Firestop Systems. The purpose-made solution for cavity fire stopping
SP Firestop Systems The purpose-made solution for cavity fire stopping SP Firestop Systems The purpose-made solution for cavity fire stopping As part of the comprehensive FIREPRO range of fire protection
More informationSafety use instruction sheet
Safety use instruction sheet 1. Company and product identification 1.1 Product: ISOVER rolls, slabs and board products of bio-soluble glass fibres, for industrial application 1.2 Field of application:
More informationRainscreen Ventilated Fire Barrier
An intumescent FR barrier for slab edge, curtain wall and façade applications Technical Data Sheet KEY BENEFITS - Allows air movement in building design whilst providing superior fire rating - Fire Resistance
More informationSAFETY DATA SHEET (SDS) IN ACCORDANCE WITH COMMISSION REGULATION (EU) NO 453/2010 (REACH) REACH registration number. EC identification number
ROCKWOOL INSULATION 1. Identification of the substance/mixture and of the company 1.1 Product identifier ROCKWOOL stone wool insulation 1.2 Relevant identified uses of the substance or mixture and uses
More informationFIREPRO FIRE DUCT SYSTEMS Single layer fire protection for rectangular, circular and oval ducts.
FIREPRO FIRE DUCT SYSTEMS Single layer fire protection for rectangular, circular and oval ducts. FIRE DUCT SYSTEMS Rectangular and circular, single layer fire protection for steel ductwork. As part of
More informationSAFETY DATA SHEET Universalskiva 1201
Universalskiva 1201 Page 1 of 7 SAFETY DATA SHEET Universalskiva 1201 SDS according to Regulation (EC) No. 1907/2006 concerning the Registration, Evaluation, Authorisation and Restriction of Chemicals
More informationDIVISION 7 THERMAL AND MOISTURE PROTECTION SECTION PENETRATION FIRESTOPPING
DIVISION 7 THERMAL AND MOISTURE PROTECTION SECTION 07 84 13 PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and
More informationGyproc Habito Plasterboard
Gyproc Habito Plasterboard Technical & Safety Data Sheet www.gyproc.ae INTRODUCTION Characteristics Gyproc Habito consists of a specially reinforced gypsum core designed for high strength and fixing capability.
More informationHP Partial Fill. Robust, long-lasting protection
1 CONSTRUCTION TYPE: cavity walls HP Partial Fill Cavity Walls Robust, long-lasting protection HP Partial Fill slabs have a robust outer surface, designed to withstand on-site rigours and maintain a clearly
More informationDuctslab and Ductwrap
Ductslab and Ductwrap For the thermal insulation of ductwork and water storage tanks ROCKWOOL provide thermal insulation for air conditioning, warm air and extract ducts used in the internal and external
More informationSECTION THROUGH-PENETRATION FIRESTOP SYSTEMS
SECTION 07841 - THROUGH-PENETRATION FIRESTOP SYSTEMS PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division
More informationRecommended Design Considerations. and. Guide Specifications For. Commercial Building Insulation
Recommended Design Considerations and Guide Specifications For Commercial Building Insulation Date of Issue: October 1, 2004 Recommended Design Considerations and Guide Specifications For Commercial Building
More informationFor inhibiting the spread of fire and smoke in concealed spaces
ZERO ODP ZERO GWP CI/SfB Km1 July 2005 (replaces July 2004 issue) (K22) OZONE DEPLETING POTENTIAL GLOBAL WARMING POTENTIAL Construction type Cavity Barriers Cert. N o. 022c Rockwool supports FIRAS accredited
More informationSoundBlocTM. Gyproc SoundBloc Plasterboard. Technical & Safety Datasheet.
SoundBlocTM Gyproc SoundBloc Plasterboard Technical & Safety Datasheet www.gyproc.ae TECHNICAL DATASHEET INTRODUCTION Characteristics Gypsum plasterboard with a higher density core specifically designed
More informationOptik. Optik. SuperSeeker Divot Mix Dye
Indigrow Ltd Safety data sheet according to Regulation (EC) No. 1907/2006. Page 1 of 5 SECTION 1: Identification of the substance/mixture and of the company/undertaking 1.1 Product Identifier 1.2. Relevant
More informationFire Barrier Systems. For inhibiting the spread of fire and smoke in concealed spaces
Fire Barrier Systems 4.09:Fire Barrier Systems 24/4/09 6: Page CI/SfB Km (K22) April 2009 (replaces September 2008 issue) Construction type Cavity Barriers Fire Barrier Systems For inhibiting the spread
More informationConforms to Regulation (EC) No. 1907/2006 (REACH), Annex II - United Kingdom (UK)
1. IDENTIFICATION OF THE SUBSTANCE/PREPARATION AND OF THE COMPANY/UNDERTAKING Identification of the substance/preparation Product name or Trade name Sikaflex -521 UV Safety Data Sheet Conforms to Regulation
More informationSept 30, 2004 Page 1
Sept 30, 2004 Page 1 This section includes a manufacturer's guide specification for TERRAFOAM EPS building insulation. Refer also to Product Description for detailed product properties, options, and other
More informationK10 FM Soffit Board. Insulation
Insulation A4/8 K10FM AW2257B Issue 14 Dec 2017 K10 FM Soffit Board Insulation for concrete soffits Super high performance rigid thermoset phenolic insulation Fibre-free, closed cell insulation core FM
More informationSAFETY DATA SHEET Flex C-skiva
Flex C-skiva Page 1 of 7 SAFETY DATA SHEET Flex C-skiva The safety data sheet is in accordance with Commission Regulation (EU) 2015/830 of 28 May 2015 amending Regulation (EC) No 1907/2006 of the European
More informationCERTIFICATE OF APPROVAL No CF 513 FSI LIMITED
CERTIFICATE OF APPROVAL No CF 513 This is to certify that, in accordance with TS00 General Requirements for Certification of Fire Protection Products The undermentioned products of Westminster Industrial
More informationSIDERISE ceiling void barriers
INTERIORS: CEILING VOID BARRIERS Version 1 : March 2015 SIDERISE ceiling void barriers High performance acoustic barriers designed for use in ceiling voids. Making your world Making your world a quieter
More informationInsulation Board. Knauf Data Sheet PE-DS
Insulation Board Knauf Data Sheet PE-DS-2 12-06 Insulation Board Description Knauf Insulation Board is a thermal and acoustical insulation product made from inorganic glass fibers preformed into boards
More informationMATERIAL SAFETY DATA SHEET
MATERIAL SAFETY DATA SHEET MANUFACTURER: ROCK WOOL MANUFACTURING COMPANY ADDRESS: 1400 7th Ct. (zip: 35094-1504) P.O. BOX 506 LEEDS, AL 35094-0506 USA PHONE: For information purposes: 8:00 AM - 5:00 PM
More informationDSC BUILDING 1200 ALTERATIONS OCTOBER 2011 SECTION DUCT INSULATION
SECTION 230713 DUCT INSULATION PART 1 GENERAL 1.1 SUMMARY A. Related Sections: 1. 233113 Ductwork and Accessories 1.2 REFERENCES A. American Society for Testing and Materials (ASTM): 1. E84-96a Test Method
More informationK12 Framing Board. Insulation
Insulation A4/8 K12 AW2161 Issue 7 Dec 2016 INSULATION FOR USE BEHIND wall lining AND FRAMED WALLS Super high performance rigid thermoset phenolic insulation Fibre-free, closed cell insulation core Can
More informationDate: Former date:
X SAFETY DATA SHEET (INFORMATION FORM FOR CHEMICALS DATA) (*) concerns only chemical notification (**) either 3.1 or 3.2 must be filled SECTION 1: IDENTIFICATION OF THE SUBSTANCE/MIXTURE AND OF THE COMPANY/UNDERTAKING
More informationRMF Intercell. NBS Specification 2013 K41
RMF Intercell NBS Specification 2013 K41 InterfaceFLOR BV. K41 Specification 40mm, 60mm, 80mm, 90mm and 110mm K41 Raised access floors To be read with Preliminaries/ General conditions. TYPES OF RAISED
More informationSection 11 FIRE STOPPING
Section 11 This section highlights the key points relating to Fire Stopping. It is imperative that sites teams understand the importance of fire stopping and check it is completed correctly. It is to be
More informationFIRE PROTECTION. GTEC Shaftwall systems 244 GTEC Shaftwall Stairwell systems 248 GTEC Horizontal Shaftwall systems 249 GTEC Encasement systems 250
FIRE PROTECTION GTEC Shaftwall range uses a specially designed system to protect voids and shafts in buildings. It resists pressure changes and enables installation from one side of the shaft only. GTEC
More informationXtratherm Thin-R Thermal Liner (XT/TL Grade)
CERTIFICATE NO. 03/0183 DETAIL SHEET 4 Xtratherm Thin-R Thermal Liner (XT/TL Grade) PRODUCT DESCRIPTION: This Detail Sheet relates to Xtratherm Thin-R Thermal Liner, as defined in NSAI Agrément Certificate
More informationGyproc Cove and Cornice
ove and ornice Introduction Overview ove and ornice are comprised of a gypsum plaster core encased in a white or ivory paper liner. The cove and cornice range is one of the easiest ways to enhance the
More informationK12 Framing Board. Insulation INSULATION FOR USE BEHIND WALL LINING AND FRAMED WALLS
Insulation A4/8 K12 AW2194 Issue 10 Sep 2017 INSULATION FOR USE BEHIND WALL LINING AND FRAMED WALLS Super high performance rigid thermoset phenolic insulation Fibre-free, closed cell insulation core Can
More informationTechnical Data. SAPPHIRE Hi-Torque (with SUPS) High performance, semi-synthetic gearbox fluids Viscosity grades: ISO VG 100, 220, 320, 460, 680
Technical Data SAPPHIRE Hi-Torque (with SUPS) High performance, semi-synthetic gearbox fluids Viscosity grades: ISO VG 100, 220, 320, 460, 680 Product Overview The ROCOL SAPPHIRE Hi-Torque range of semisynthetic
More informationTechnical Data. SAPPHIRE Hi-Power Oils. Hydraulic, airline and compressor oils ISO VG 22, 32, 46, 68, 100. Product Overview
Technical Data SAPPHIRE Hi-Power Oils Hydraulic, airline and compressor oils ISO VG 22, 32, 46, 68, 100 Product Overview Directions for Storage and Use ROCOL SAPPHIRE Hi-Power oils are high performance,
More informationSAFETY DATA SHEET. PC24: Lubricants, greases, release products. This product has no classification under CHIP.
Page: 1 Compilation date: 21/11/2012 Revision No: 1 Section 1: Identification of the substance/mixture and of the company/undertaking 1.1. Product identifier Product name: 1.2. Relevant identified uses
More informationSAFETY DATA SHEET SUPERCAST PVC WATERSTOPS
SAFETY DATA SHEET SECTION 1: Identification of the substance/mixture and of the company/undertaking 1.1. Product identifier Product name Product number Synonyms; trade names 238xxxxUK9 HYDROFOIL,ANGLEGUARD,REARGUARD
More information1. IDENTIFICATION OF THE SUBSTANCE/PREPARATION AND OF THE COMPANY/UNDERTAKING. SIKA Schweiz AG Tüffenwies Zürich Switzerland
Safety Data Sheet Conforms to Regulation (EC) No. 1907/2006 (REACH), Annex II - Switzerland 1. IDENTIFICATION OF THE SUBSTANCE/PREPARATION AND OF THE COMPANY/UNDERTAKING Identification of the substance/preparation
More informationHILTI CP 674 Cavity Closure For Rainscreen / Cladding Systems
Data Sheet HILTI CP 674 Cavity Closure For Rainscreen / Cladding Systems The enclosed pages are taken from the Hilti Firestop Systems Manual Edition April 2011 Supported by additional standard details
More informationMATERIAL SAFETY DATA SHEET Easy-form TM Caulking Foam
MATERIAL SAFETY DATA SHEET Easy-form TM Caulking Foam Introduction This Safety Data Sheet contains the following information and advice. Contents 1. Identification of: 1.1 Product 1.2 Company 2. Product
More information1. IDENTIFICATION OF THE SUBSTANCE/PREPARATION AND THE COMPANY/UNDERTAKING
1. IDENTIFICATION OF THE SUBSTANCE/PREPARATION AND THE COMPANY/UNDERTAKING Product information Trade name : Filament wound, pultruded and fabricated carbon fibre products Use : Yacht masts & spars, telescopes,
More informationSAFETY DATA SHEET. Blanket D-24B
Blanket D-24B Page 1 of 7 SAFETY DATA SHEET Blanket D-24B SDS according to Regulation (EC) No. 1907/2006 concerning the Registration, Evaluation, Authorisation and Restriction of Chemicals (REACH), Annex
More informationVersion 3.0 Print Date 2011/02/23 Revision Date 2011/02/ Identification of the substance/mixture and of the company/undertaking
1. Identification of the substance/mixture and of the company/undertaking 1.1. Product identifier Trade name : EC-No. : 200-289-5 1.2. Relevant identified uses of the substance or mixture and uses advised
More information1. PRODUCT AND COMPANY IDENTIFICATION. : Product Stewardship (770)
Page 1 of 6 1. PRODUCT AND COMPANY IDENTIFICATION POLYONE CORPORATION 33587 Walker Road, Avon Lake, OH 44012 NON-EMERGENCY TELEPHONE Emergency telephone number : Product Stewardship (770) 271-5902 : CHEMTREC
More informationXtratherm Thin-R Partial Fill Cavity Wall Board (XT/CW Grade)
CERTIFICATE NO. 03/0183 DETAIL SHEET 1 Xtratherm Thin-R Partial Fill Cavity Wall Board (XT/CW Grade) PRODUCT DESCRIPTION This Detail Sheet relates to Xtratherm Thin-R Partial Fill Cavity Wall Board, as
More informationMATERIAL SAFETY DATA SHEET Easy-form TM Open Cell Backer Rod
MATERIAL SAFETY DATA SHEET Easy-form TM Open Cell Backer Rod Introduction This Safety Data Sheet contains the following information and advice. Contents 1. Identification of: 1.1 Product 1.2 Company 2.
More informationMaterial Information Data Sheet
Material Information Data Sheet Polyurethane - flexible foam Issue date: 6 th June 2013 Material: Polyurethane flexible foam or PUR Manufacturer: Carpenter Ltd Address: Dinting Lodge Industrial Estate,
More informationMATERIAL SAFETY DATA SHEET
MATERIAL SAFETY DATA SHEET SECTION 1: PRODUCT AND COMPANY IDENTIFICATION Product Name: BH Therm-L-Wrap Manufacturer: Federal-Mogul Corporation 26555 rthwestern Highway Southfield, MI 48033 MSDS# BH-127
More informationGypLyner. GypLyner. Metal framed wall lining system. All our systems are covered by SpecSure when using genuine Gyproc and Isover products.
GypLyner GypLyner Metal framed wall lining system All our systems are covered by SpecSure when using genuine Gyproc and Isover products Linings GypLyner GypLyner is a cost-effective, virtually independent
More informationTARMAC BUXTON LIME & POWDERS
TARMAC BUXTON LIME & POWDERS Tarmac Buxton Lime and Cement PRODUCT SAFETY DATA SHEET TRUCARB and TRUCAL 1. IDENTIFICATION OF THE SUBSTANCE AND COMPANY 1.1 Product name: Other names Trucal Limestone granules
More informationSAFETY DATA SHEET. Extremely flammable. Harmful to aquatic organisms, may cause long-term adverse effects in the aquatic environment.
Page: 1 Compilation date: 13/02/2012 Revision No: 4 Section 1: Identification of the substance/mixture and of the company/undertaking 1.1. Product identifier Product name: 1.2. Relevant identified uses
More informationMaterial Safety Data Sheet Maxcare Pine Disinfectant Crescent Brands
Page: 1 of 6 1. IDENTIFICATION OF THE SUBSTANCE AND COMPANY DETAILS 1.1 BRAND NAME Maxcare 1.2 PRODUCT CATEGORY Detergent.Disinfectant. Washing and cleaning. 1.3 COMPANY NAME UK 1.4 COMPANY CONTACT DETAILS
More informationMATERIAL SAFETY DATA SHEET
MATERIAL SAFETY DATA SHEET SECTION 1: PRODUCT AND COMPANY IDENTIFICATION Product Name: BH ReflectShield Manufacturer: 1450 Federal-Mogul Corporation 26555 Northwestern Highway Southfield, MI 48033 MSDS#
More informationPANTONE 365U
Page 1 of 6 1. PRODUCT AND COMPANY IDENTIFICATION POLYONE CORPORATION 33587 Walker Road, Avon Lake, OH 44012 NON-EMERGENCY TELEPHONE Emergency telephone number : Product Stewardship (770) 271-5902 : CHEMTREC
More informationMATERIAL SAFETY DATA SHEET
MATERIAL SAFETY DATA SHEET SECTION 1: PRODUCT AND COMPANY IDENTIFICATION Product Name: BH ReflectSleeve Manufacturer: 1450 E Federal-Mogul Corporation 26555 rthwestern Highway Southfield, MI 48033 MSDS#
More informationFire Barrier Duct Wrap 615+
Fire Barrier Duct Wrap 615+ Duct Wrap Fire Protection System for Commercial Kitchen Grease and Ventilation Air Ducts Product Data Batts and blankets for use in fire resistive duct assemblies see UL fire
More information1. IDENTIFICATION OF THE SUBSTANCE/PREPARATION AND OF THE COMPANY. Silica sand and quartz gravel, fire-dried or moist from stockpile
1. IDENTIFICATION OF THE SUBSTANCE/PREPARATION AND OF THE COMPANY 1.1 Identification of the substance, fire-dried or moist from stockpile Index no.: not applicable EINECS: 238-878-4 CAS-no.: 14808-60-7
More informationMaterial Information Data Sheet
POLYURETHANE FLEXIBLE FOAM Material Information Data Sheet Introductory Note This Information Data Sheet on Polyurethane Flexible Foam aims to deliver information needed for the safe handling and use of
More informationSAFETY DATA SHEET. SECTION 1: Identification of the substance/mixture and of the company/undertaking
SAFETY DATA SHEET SECTION 1: Identification of the substance/mixture and of the company/undertaking 1.1 Product identifier Product name: Eastman Amphora(TM) 3D Polymer HT5300 Product No.: HT5300, 50190538,
More informationIdent-No: ARALDITE AY 103
1. IDENTIFICATION OF THE SUBSTANCE/PREPARATION AND THE COMPANY/UNDERTAKING Product information Trade name : ARALDITE AY 103 Use : Resin for adhesive systems Company : Huntsman Advanced Materials (UK) Ltd
More informationSAFETY DATA SHEET. Mineral Wool 1200 Insulation. Section I. Identification. Section II. Hazards Identification
SAFETY DATA SHEET Mineral Wool 1200 Insulation Section I. Identification Identity: Mineral Wool 1200 Insulation - Board, Fitting Insulators Product Use: Insulation Board, Fitting Insulators Manufacturer
More information1. PRODUCT AND COMPANY IDENTIFICATION 2. COMPOSITION/INFORMATION ON REGULATED INGREDIENTS
Page 1 of 6 POLYONE CORPORATION 33587 Walker Road, Avon Lake, OH 44012 1. PRODUCT AND COMPANY IDENTIFICATION Telephone : Product Stewardship (770) 271-5902 Emergency telephone : CHEMTREC 1-800-424-9300
More informationPromat PROMASEAL Fire Barrier
Promat PROMASEAL Fire Barrier PRODUCT DESCRIPTION Promat PROMASEAL Fire Barriers are slabs of high density rock wool with a white endothermic, ablative coating. APPLICATION Promat PROMASEAL Fire Barriers
More informationGypLyner UNIVERSAL Metal framed wall lining system
Metal framed wall lining system Pizza Express, York 30 Metal framed wall lining system wall lining system is a cost-effective, virtually independent metal frame drylining. It is a general purpose system
More informationPart E robustdetails. robustdetails. January 2017 Update Pack. Dear Colleague,
Part E Pack Dear Colleague, This is the first 2017 update to the Part E Robust Details Handbook. In this update pack, we have focussed on clarifying the situation on incorporating underfloor heating (UFH)
More informationMATERIAL SAFETY DATA SHEET
MATERIAL SAFETY DATA SHEET SECTION 1: PRODUCT AND COMPANY IDENTIFICATION Product Name: BH Aluminized Thermocloth Manufacturer: Federal-Mogul Corporation 26555 rthwestern Highway Southfield, MI 48033 MSDS#
More informationSAFETY DATA SHEET. Calcium acetate Ref.50274/1.1/REG_EU/EN Revision Date: Previous date: Print Date:
1. IDENTIFICATION OF THE SUBSTANCE/MIXTURE AND OF THE COMPANY/UNDERTAKING 1.1 Product information Commercial Product Name Chemical name: Registration number: 01-2119987569-11-0001 1.2 Relevant identified
More informationSAFETY DATA SHEET according to Regulation (EU) No. 1907/2006
1. IDENTIFICATION OF THE SUBSTANCE/PREPARATION AND OF THE COMPANY/UNDERTAKING Product information Trade name : Use : Production of moulded plastic articles Company Bayer MaterialScience AG BMS-IO-HSEQ-PSI
More informationSAFETY DATA SHEET. SECTION 1: Identification of the substance/mixture and of the company/undertaking
SAFETY DATA SHEET SECTION 1: Identification of the substance/mixture and of the company/undertaking 1.1 Product identifier Product name: Eastman Amphora(TM) 3D Polymer AM3300 Product No.: AM3300, 50183228,
More informationSt. Monica Food Pantry
St. Monica Food Pantry 07 8400-1 SECTION 07 8400 - FIRESTOPPING PART 1 - GENERAL 1.1 SUMMARY: A. Related work: 1. Concrete. 2. Mortar and grout. 3. Brick masonry. 4. Concrete unit masonry. 5. Structural
More informationACS Material LLC. Safety Data Sheet Silicon Monoxide. Version: 1.2 / EN Revision Date: 7/27/2017
Version: 1.2 / EN Revision Date: 7/27/2017 SECTION 1: IDENTIFICATION OF THE PRODUCT AND OF THE COMPANY 1.1 Product identifiers Product Name : ACS Material Silicon Monoxide Brand : CAS-No. : 10097-28-6
More informationProduct Information Data Sheet Polyurethane bonded flexible foam
Product Information Data Sheet Polyurethane bonded flexible foam Issue date: March 2009 Product: Bonded foam, based on flexible polyurethane Foam, mixed with either cork, latex foam, rubber or polyurethane
More informationT-Barrier System. Masonry Applications. Satisfying Fire, Thermal and Acoustic Requirements at the Combined Party Wall and Pitched Roof Junction
T-Barrier System Masonry Applications Satisfying Fire, Thermal and Acoustic Requirements at the Combined Party Wall and Pitched Roof Junction The Problem: Thermal Bypass Without effective edge sealing,
More informationProduct Information Data Sheet
Product Information Data Sheet Issue date: September 2015 Product: Polyurethane flexible foam Description of foam type: High Resilient PUR foam Manufacturer: Sandella N-6230 Sykkylven, Norway, Phone:+47
More information10% Ultramarine Violet 5011
Page 1 of 5 1. PRODUCT AND COMPANY IDENTIFICATION POLYONE CORPORATION 33587 Walker Road, Avon Lake, OH 44012 NON-EMERGENCY TELEPHONE Emergency telephone number : Product Stewardship (770) 271-5902 : CHEMTREC
More informationMATERIAL SAFETY DATA SHEET
MATERIAL SAFETY DATA SHEET SECTION 1: PRODUCT AND COMPANY IDENTIFICATION Product Name: BH Fyrejacket and Fyretape Manufacturer: Federal-Mogul Corporation 26555 rthwestern Highway Southfield, MI 48033 MSDS#
More informationSAFETY DATA SHEET PUMICE POWDER This SDS is not mandated under REACH Regulation (EC) No 1907/2006 and is provided for information only.
SAFETY DATA SHEET This SDS is not mandated under REACH Regulation (EC) No 1907/2006 and is provided for information only. SECTION 1: Identification of the substance/mixture and of the company/undertaking
More informationSECTION BUILDING INSULATION. Display hidden notes to specifier. (Don't know how? Click Here)
PART 1 GENERAL 1.1 SECTION INCLUDES SECTION 07210 BUILDING INSULATION Display hidden notes to specifier. (Don't know how? Click Here) A. Perimeter Fire Containment Systems. B. Building Insulation for Thermal
More informationAcoustic Cradle Levelling System
Acoustic Cradle Levelling System CONCRETE FLOOR CRADLE & BATTEN Datasheet 52 01 18mm t&g chipboard @ 400mm centres 02 40mm min directly applied sand & cement or proprietary screed (min 80kg/m 2 ) 03 03
More information3.1. Substance Not applicable 3.2. Mixture Name Product identifier % Classification (GHS-US) Phosphite antioxidant Aquatic Chronic 1, H410
SECTION 1: Identification 1.1. Identification Product name : Polypropylene 1.2. Relevant identified uses of the substance or mixture and uses advised against Use of the substance/mixture : Manufacturing
More informationSection 1. Identification
Safety Data Sheet Cotton Fiber Abrasive Products Revision: Section 1. Identification Product name: Rex-Cut Abrasives cotton fiber abrasive products; Mounted Points, Type 1 wheels, High Speed Type 1 wheels,
More informationALUMINUM OXIDE COMMERCIAL GRADE
TECHNICAL & MATERIAL SAFETY DATA SHEET ALUMINUM OXIDE COMMERCIAL GRADE Brown Fused Alumina is a durable non ferrous abrasive that is produced in a way that generates a blocky shaped particle. This grain
More informationGantiel Vensott E.P.S. Pty. Ltd. Vendel N_B. [ White_Black Acetal ] Material Safety Data Sheet
Product Name: White_Black Acetal Company Name: antiel ensott E.P.S. Pty. Ltd. Address: 15, Bearing Road, Seven Hills, NSW 2047 Telephone No: +61 2 8678 9491 Fax No: +61 0 8678 9492 Email: sales@gantiel.com
More informationSAFETY DATA SHEET FIRESTOP 400 VIT
FIRESTOP 400 VIT Page 1 of 7 SAFETY DATA SHEET FIRESTOP 400 VIT SDS according to Regulation (EC) No. 1907/2006 concerning the Registration, Evaluation, Authorisation and Restriction of Chemicals (REACH),
More informationRAINSCREEN DUO SLAB. Non-combustible thermal insulation
RAINSCREEN DUO SLAB Non-combustible thermal insulation RAINSCREEN DUO SLAB Effective, non-combustible thermal insulation for ventilated rainscreen and overcladding applications RAINSCREEN DUO SLAB is a
More informationMechanical carbon products; grades that contain antimony
SAFETY DATA SHEET SDS NA-MC102 Section 1 Product and Supplier Identification Product identifier used on the label: Other means of identification: Uses (and restrictions): Supplier and contact information:
More informationMATERIAL SAFETY DATA SHEET
MATERIAL SAFETY DATA SHEET SECTION 1: PRODUCT AND COMPANY IDENTIFICATION Product Name: BH ReflectShield Manufacturer: 1435 Federal-Mogul Corporation 26555 rthwestern Highway Southfield, MI 48033 MSDS#
More information: RT100S G or D Big Blu
SECTION 1: Identification of the substance/mixture and of the company/undertaking 1.1. Product identifier Product form Product name : Mixture : 1.2. Relevant identified uses of the substance or mixture
More informationSafety Data Sheet According to 1907/2006/EC, article 31
1. IDENTIFICATION OF THE COMPANY / UNDERTAKING: DuoTech Limited 11-12 Queen Square Bristol BS1 4NT Telephone: 0845 519 1112 Fax: 0845 519 1113 Emergency Telephone: 0845 519 1112 Out of hours: 07855 845
More informationMaterial Safety Data Sheet. : Oleo Pine Resin
Material Safety Data Sheet Oleo Pine Resin Section 1 - Chemical Product and Company Identification MSDS Name : Oleo Pine Resin Synonyms : Pine Resin Turpentine Company Identification : Tradeasia International
More informationZIRCONIUM DIOXIDE MSDS
ZIRCONIUM DIOXIDE MSDS 1. Product Identification 1.1 Chemical Name: zirconium dioxide 1.2 Chemical Formula: ZrO 2 1.3 application / preparation: zirconium for dental use 1.4 producer/supplier: Rizhao Huge
More informationConforms to EU regulation EC 1907/2006 and amendments PREMIER KLERCIDE-CR STERILE BIOCIDE C
SAFETY DATA SHEET Conforms to EU regulation EC 1907/2006 and amendments PREMIER KLERCIDE-CR STERILE BIOCIDE C Code 111034E Version 1 Date of revision 24 June 2010 1. Identification of the substance/preparation
More informationEUROPEAN ORGANISATION FOR TECHNICAL APPROVALS
E TA TECHNICAL REPORT Fire Resistance Tests for Cavity Barriers TR 31 Edition October 2008 EUROPEAN ORGANISATION FOR TECHNICAL APPROVALS EOTA TECHNICAL REPORT TR 031 Fire Resistance Tests for Cavity Barriers
More informationJune Residential Refurbishment Separating walls
June 2010 Residential Refurbishment 3.6.1 Separating walls Residential refurbishment 3.0 Residential Refurbishment Separating Walls Contents Introduction find online page Solution optimiser and pathfinder
More informationSAFETY DATA SHEET. Thermally Conductive Ultra-soft silicone pad for electronic components. This product has no classification under CLP.
Page: 1 Compilation date: 18/10/2017 Revision No: 1 Section 1: Identification of the substance/mixture and of the company/undertaking 1.1. Product identifier Product name: Product code: 1.2. Relevant identified
More informationGypLyner UNIVERSAL Metal framed wall lining system
Metal framed wall lining system! This section includes updated information, added since it was first published in July 009. Please see the WHITE BOOK update document for details. Last updated 0/0/00 Cadbury
More information