PLANNING REPORT CITY OF EAGAN. APPLICANT: Ryan Companies US, Inc. HEARING DATE: June 23, 2015

Size: px
Start display at page:

Download "PLANNING REPORT CITY OF EAGAN. APPLICANT: Ryan Companies US, Inc. HEARING DATE: June 23, 2015"

Transcription

1 PLANNING REPORT CITY OF EAGAN REPORT DATE: June 16, 2015 CASE: 19-RZ ; 19-PD ; 19-FP APPLICANT: Ryan Companies US, Inc. HEARING DATE: PROPERTY OWNER: MN Autism Center APPLICATION DATE: June 3, 2015 REQUEST: Rezoning, Preliminary Planned Development and Final Plat PREPARED BY: Sarah Thomas LOCATION: West of 3800 Tesseract Place COMPREHENSIVE PLAN: MU, Mixed Use ZONING: CGD, Cedar Grove District SUMMARY OF REQUEST The applicant is requesting approval of a Rezoning from CGD (Cedar Grove District) to PD (Planned Development), a Preliminary Planned Development for proposed Lot 1, Block 1, Tesseract 2nd Addition, to allow a high school and school campus and a Final Plat to create a single parcel. The subject site is located at 3800 Tesseract Place. Execution of the Planned Development Agreement will simultaneously constitute the Final Planned Development Agreement for the property. AUTHORITY FOR REVIEW Rezoning: City Code Chapter 11, Section 11.50, Subd. 5 states in part, 1. The provisions of this chapter may be amended by the majority vote of the council, except that amendments changing the regulations of any district may only be made by an affirmative vote of two-thirds of all members of the council. 2. The City Council shall not rezone any land or area in any zoning district or make any other proposed amendment to the zoning ordinance without first having referred it to the planning commission for its consideration and recommendation.

2 Page 2 Planned Development: City Code Chapter 11.60, Subd. 18, A., states the intent of the Planned Development zoning district as follows: 1. Providing greater flexibility in environmental design and relaxation of strict application of the zoning ordinance in exchange for greater creativity and environmental sensitivity. 2. Recognizing the economic and cultural advantages that will accrue to the residents of a planned community. 3. Encouraging a more creative and efficient approach to the use of the land. 4. Encouraging the preservation and enhancement of desirable site characteristics, natural features, and open space. 5. Encouraging a development pattern that is consistent with land use density, transportation facilities and community facilities objectives of the Comprehensive Plan. BACKGROUND/HISTORY The subject property is zoned CGD (Cedar Grove District) and was platted in The eastern parcel, currently occupied by the MN Autism Center, was previously zoned I-1, Limited Industrial. The former use, Tesseract School, received approval to rezone the property to PD, Planned Development to allow the construction of the school in A PD Amendment to allow an expansion of the school was approved in The City Council initiated a rezoning of 128 acres of land in 2003 which included the subject property. The property was rezoned to CGD, Cedar Grove District. A Conditional Use Permit (CUP) was approved in 2011 to allow a school in the CGD zoning district. The western parcel is an Outlot. EXISTING CONDITIONS The 13 acre site is currently comprised of three individual parcels and abuts public right-of-way on the north (Silver Bell Road), east (Tesseract Place), west (Nicols Road) and south (Highway 13). All of these streets are currently classified as Local streets. A sidewalk extends along the south side of Silver Bell Road from Nicols Road to TH 13. The site contains multiple drainage and utility easements located over the northern half of the site. The southern portion of the property, adjacent to Highway 13, has an existing billboard that is accessed from Nicols Road.

3 Page 3 Site grading, the installation of utilities (water, storm sewer, and sanitary sewer) and a stormwater pond, parking lots and an existing 34,000 sq. ft. school building were constructed with the original development of the eastern parcel (Lot 1, Block 1, Tesseract Addition). The middle parcel, Outlot A, and the unplatted western parcel, are currently undeveloped. The southern and western portions of the site have light tree coverage. SURROUNDING USES The following existing uses, zoning, and comprehensive guide plan designations surround the subject property: Existing Use Zoning Land Use Designation North Silver Bell Road, R-1, Single-family residential LD, Low Density Residential Wuthering Heights neighborhood East Vacant; L1, B1, CGD, Cedar Grove District BP, Business Park Cedar Grove Gateway 1st Addition South Hwy 13 West Goodyear service garage CGD, Cedar Grove District MU, Mixed Use EVALUATION OF REQUEST Description of Proposal The proposed development consists of the construction of a 2-story, 48,000 square foot high school building, an athletic field and a parking lot. The three separate parcels are proposed to be combined into one property to create a school campus. The applicant s narrative states...the need for MAC s (Minnesota Autism Center) services is at an all-time high as ASD (Autism Spectrum Disorder) is becoming more and more prevalent. It is estimated that 1 in every 68 children are diagnosed with ASD...with the expansion capacity, MAC will employ over 200 staff members at their Eagan location and treat well over 200 students. Compatibility with Surrounding Area Surrounding development to the west includes a service garage. To the south, across Highway 13, is the Twin Cities Premium Outlet Mall. The property to the east is vacant. To the north, across Silver Bell Road are residential homes. Consistency with Comprehensive Guide Plan This proposal should be evaluated on how well it achieves the goals and policies of the Comprehensive Guide Plan. On March 17, 2015, the City Council heard a request to amend the land use designation of the subject site from MU (Mixed Use) to QP (Public/Quasi-Public). The City Council indicated openness to an educational use in this location, pending review of a complete development application, and directed city staff to submit the amendment to the Metropolitan Council. The Metropolitan Council Review letter states the City may place this amendment into effect and offers advisory comments related to

4 Page 4 employment forecasts, land use and transportation/aviation. The letter is included as an exhibit. As is the City s practice, Council action to approve or deny the Comprehensive Plan Amendment will occur at the time the development application (Rezoning and PD) is considered by the Council. The City s 2030 Comprehensive Guide Plan focused on three planning trends of Sustainability, Active Living, and Connectivity. These themes are woven throughout multiple chapters of the City s Comprehensive Guide Plan. In addition, the Cedar Grove Commons Special Area Plan includes specific goals and policies which include: to encourage a mixture of market-supportable land uses compatible with one another and with the surrounding area to protect long term vitality of residential areas adjacent to commercial areas and consider the needs of existing businesses that are expected to remain within the redevelopment area to be attractive from Highway 77/Highway 13, as well as their primary access to incorporate sound attenuating construction techniques, as warranted, on new construction Planned Development and Public Benefit The property is currently zoned CGD, Cedar Grove District. The CGD zoning district was established in 2002 as a tool to implement the principles of the Cedar Grove Design Framework for compact mixed-use development with an urban design that is pedestrian friendly. To this end, the CGD district establishes specific standards related to site planning, architecture, building materials, landscaping, signage and other elements. By its nature, the Cedar Grove Redevelopment District is expected to involve compact and more intense development than is the case in other areas of the City. While the CGD Zoning District permits that to occur, in order to be implemented, the details of individual developments may not align with all of the specific requirements of the Zoning District. As a consequence, the City anticipates that the developments within the district will reflect the general expectations of the Code, but will be implemented through Planned Development Zoning, with the specific plans being compared to the standards of that district as well as the redevelopment goals and principles of the Cedar Grove Commons Special Area Plan of the City s Comprehensive Guide Plan. Within the City Code, Planned Development zoning is provided as an option to permit consideration of development that may deviate from the strict application of the Code, in ways that benefit the property owner/developer and that benefit the City in consideration for permitting the deviations. The developer is requesting some deviations to typical Code requirements such as for multiple buildings on one lot, setbacks exceeding the 0-10 build-to line, building materials and architecture, signage, landscaping and parking. This report evaluates the proposed Planned Development in comparison to the CGD zoning district and other City zoning standards, as well as the principles of both the Cedar Grove Commons Special Area Plan and the Cedar Grove Design Framework. Whether there are benefits that can be defined for the City for permitting the Planned Development zoning and deviations is a policy issue for decision makers.

5 Page 5 Rezoning and Preliminary Planned Development: Use The CGD Zoning District allows schools via a conditional use. Term Staff suggests a five-year term for this Planned Development. Conforming Plan The applicant provided a Conforming Plan which includes a conforming Site Plan, Landscape Plan and building elevations. The Site Plan shows the building adjacent to the public right-of-way at the build-to line with parking behind the structure. The plans note complications with the conformation plans: Site Plan Student safety Proximity to neighborhood Slope of Silver Bell Road Elevation of the site Landscape Plan No open space Competitive growth No organization Elevation Plan Building massing Front door Site Plan The Site Plan provides for access to the site from Silver Bell Road. The driveway provides access to both the existing and proposed school and their affiliated parking areas. No changes to the existing school/site are proposed save for handicap parking stall striping. The proposed 2-story, 48,000 sq. ft. building will consist of classrooms, meeting rooms, assembly areas and a gymnasium inside the proposed building. Additionally, the plan provides for a shared soccer and kickball field, intended to be used by the students from both facilities. The new construction will include the addition of 179 parking stalls (103 existing) for a total of 270 parking stalls on site. The design allows traffic to both enter and exit the parking lots in this location. Traffic is also able to exit the property via the second driveway on the east side of the site. A student drop off area is planned for the new school similar to that of the existing school. A sidewalk provides a linkage between the two schools. Two infiltration basins are proposed in the NW and SW corners of the property, surrounded by a 7 chain link fence. A Building Permit is required for any fence 7 or taller.

6 Page 6 Lastly, the plan identifies a potential expansion area up to 8,680 sq. ft. as well as a future playground and future track. Lots The site consists of a developed lot, an Outlot and an uplatted parcel. These lots will be combined via a Final Plat to become Lot 1, Block 1, Tesseract 2 nd Addition. Airport Noise Considerations The site is located within Airport Noise Policy Zone 4 one-mile Buffer. Sec , Aircraft Noise Zone Overlay District, applies to new construction within this area. Within the Buffer of Zone 4, Educational uses are considered Provisional Uses. The Provisional rating means a use that is not permitted, unless it meets certain structural performance standards for noise reduction, and satisfies several land use compatibility factors identified in the Metropolitan Council s 2030 Transportation Plan. If allowed, Provisional land uses must meet structure performance standards for interior sound reduction. Setbacks The CGD zoning district establishes a minimum front yard setback of 0 and maximum of 10, a minimum setback of 0 for side yards, and a minimum setback of 20 for rear yards. Parking setbacks are a minimum of 5. A maximum of 15% of the street frontage should be occupied by off-street parking. CGD zoning prohibits on-grade parking directly in front of a building and within 50 of any intersection. The proposed front yard setback is 360 which far exceeds the 10 maximum. In the rear yard, the proposed building setback is approximately 170, with a potential building expansion at 110. In the side yard, the west side is set back 65. The east side setback accommodates the athletic fields. While the CGD district encourages building placement near the street with less than 10 setbacks, it should be noted that half of the site was built under different zoning standards. This also impacts the parking lot design given the fixed location of the existing parking lot. The existing parking lot alone occupies roughly 47% of the street frontage. The proposed parking lot is also located in the front yard and cumulatively they occupy approximately 70% of the street frontage. The new parking lot does exceed the 50 intersection setback given the infiltration basin is located in the NW corner of the site. Lot Coverage CGD zoning does not specifically establish a maximum building to lot area coverage ratio. This is consistent with the goal of achieving a more urban redevelopment and providing maximum flexibility for a mix of uses within the Cedar Grove District. The proposed project, including the potential building expansion, consists of 44% impervious surface on 13 acres. The total building area is 90,702 s.f., which translates to a building coverage percentage of 16%. Topography/Grading The entire western two parcels will be disturbed for development. The site generally slopes from east to west, with elevations ranging from 805 to 780.

7 Page 7 The preliminary grading plan is acceptable with modification. A detailed grading, drainage, erosion, and sediment control plan should be prepared in accordance with current City standards and codes prior to final planned development approval. All erosion/sediment control plans submitted for development and grading permits should be prepared by a designer who has received current Minnesota Department of Transportation (MNDOT) training, or approved equal training as determined by the City Engineer in designing stormwater pollution prevention plans. Also, all personnel responsible for the construction and management of erosion/sediment control devices, and the establishment of vegetation for the development, should have received Erosion/Sediment Control site management certification through the University of Minnesota, or approved equal training as determined by the City Engineer. Erosion control measures should be installed and maintained in accordance with City Code and engineering standards. Storm Water Management/Water Quality The preliminary storm drainage plan is acceptable with modification. The entire site lies within Drainage District A (as designated in the City Storm Water Management Plan 2007) and generally flows northwest toward the Minnesota River. The applicant proposes to develop the vacant portion of the site, resulting in 3.08 acres of new impervious surface and an additional 3.92 acres of disturbed/graded soils, on the western portion of the acre site. This new development will need to comply with the City s Post Construction Stormwater Management Requirements (City Code 4.34) for stormwater management and surface water quality, including Runoff Rate Control and 1.1 Volume Control. The applicant proposes to meet City water quality requirements through construction of two infiltration basins, one forebay immediately upstream of the largest infiltration basin, and soil remediation for the 3.92-acres of disturbed/graded soil areas that are proposed to be revegetated pervious surfaces. For the existing site, rate control, currently being provided by a pond/basin, which is proposed to be filled, will instead be provided within the proposed northwest infiltration basin, as well as for rate control of the new development. Eagan Water Resources has reviewed the applicant s plans, stormwater design summary and modeling provided for stormwater management and finds the proposed plans to meet City Code 4.34 Post-Construction Stormwater Management Requirements are acceptable with conditions to ensure infiltration capability, effective soil remediation, construction staging and oversight, and future maintenance for continued function. Wetlands Because there are no wetlands on site, City Code 11.67, wetland protection and management regulations, does not apply. Utilities The preliminary utility plan is acceptable. A lateral water main and sanitary sewer of sufficient size and capacity is available through the middle of the site for connection and extension with development of the property. Sanitary Sewer District CG, as designated in the City s Comprehensive Sanitary Sewer Plan, serves the entire site. All utilities are proposed to be privately owned and maintained. This development should provide hydrant spacing and locations in accordance with City Fire Department and Public Works standards.

8 Page 8 In 2004, the Eagan Technology Task Force recommended that broadband and fiber optic telecommunications networks be expanded in the city wherever possible. The applicant should submit a proposal/infrastructure plan to be approved by staff to provide telecommunications fiber to the premises (FTTP) The applicant should provide such a plan for review and approval by City staff. This development should include the installation of fiber optic cable, or a conduit for future installation, in its construction plans at the time of Building Permit. Streets/Access/Pedestrian Circulation Silver Bell Road, along the north edge of the site, is a two-lane local roadway with a concrete sidewalk in the south boulevard. Tesseract Place, currently a public cul-de-sac, is the existing access point to the development. Tesseract Place right-of-way is proposed to be vacated and converted into a private street. All access to the development is proposed via this private street off of Silver Bell Road. Nicols Road, along the west edge of the site, is in the process of being designated as a Minimum Maintenance Road, therefore is not appropriate to be used as an access to the site. The Site Plan includes the extension of the existing sidewalk from the eastern parcel along the northern side of the new proposed building. No new pedestrian connections are proposed to the public sidewalk along Silver Bell Road. No Parking/Fire lane signage should be installed in the parking lot and driveways, per Fire Department standards, to ensure emergency vehicle access. Easements/Permits/Right-of-Way The existing public drainage & utility easements and the Tesseract Place right-of-way, will be vacated, and standard easements will be dedicated with the new plat. Tesseract Place will be turned into a private street so no right-of-way will be necessary. This development should be responsible for the acquisition of all regulatory agency permits required by the affected agency prior to building permit approval Parking The City Code does not have a specific requirement of off-street parking spaces for schools; however, the City Code states the Council should determine the adequacy of parking when approving a Site Plan. The Site Plan notes the proposed parking stall count has been established based on the projected use of the tenant. The site currently has 103 stalls, three of which will be removed with site modifications. Staff is unaware of any parking concerns affiliated with the existing site. The proposed total stall count is 279 stalls for the campus. City Code requires parking stalls to be 10 x 19 with a minimum of 24 drive aisles. The existing stalls do not meet this requirement as they are 9 x 18 with 26 drive aisles. The proposed stalls are 9 x 19 with 25 drive aisles. According to the applicant s narrative, this size of a parking stall slightly reduces the amount of impervious surface area which can be used for athletic fields and better fits to typical industry standards.

9 Page 9 Site Lighting The CGD district restricts pole lights to a maximum height of 20. A minimum illumination of 0.5 footcandles is required in surface parking lots, with lighting averaging 1.5 footcandles. Lighting should not exceed 0.5 footcandles at the property lines, and no glare should be directed onto adjacent right-of-way or neighboring properties. The applicant is proposing to utilize an LED pole-mounted fixture. Wall-mounted down lighting is proposed for the building. The Photometric Lighting Plan is acceptable with modification at the time of Building Permit, illustrating levels of illumination in conformance with CGD standards at the property line. Total pole height and wall-mounted fixtures should not exceed 20. Green Space The CGD ordinance does not set any standard for green space, and storm drainage and water quality treatment are handled in area ponds. Building Architecture The CGD district contains specific provisions related to building design and exterior finish materials. The applicant s narrative speaks to the proposed deviations from the City Code standards. Height The proposed building is two stories and 30 in height which exceeds the minimum height requirement of 24. Architectural Design The CGD zoning district established architectural design criteria for buildings more than 50 in length. These criteria include providing horizontal and vertical offsets, recessed windows on the first floor, and use of different materials or textures to architecturally divide the façade into bays between 20 and 40 in width. In addition, finish materials on all sides of a building should be treated as a front side and have the same finish materials, major materials shall be complementary colors, and use of both vertical and horizontal pattern designs in the building façade. The existing MAC school is a single-story painted CMU (concrete masonry unit) building. The applicant s narrative states, Rather than replicate the existing building, the MAC High School design team chose to complement the existing building with an upgraded two story design to preserve green space on the site for student program use. The proposed building has a flat roof. The use of different materials and colors provides vertical and horizontal offsets for both the length and height of the building; however, some of these sections exceed 40 in length. While finish materials are similar on each side, the south elevation has more than double the amount of precast concrete panels than the north elevation which has a higher amount of glazing. This is due to the floor plan and the gymnasium being located in the rear of the building. Given the scale and location of the building, and type of use being a school, the acceptability of the building architecture is a policy matter to be determined by City officials.

10 Page 10 Building Materials The CGD zoning district establishes that primary materials cover at least 60% of the façade, and secondary materials occupy not more than 30% of the façade. Accent materials may make up not more than 10%. Primary materials include brick, stone and glass; secondary materials may include decorative block or integrally-colored stucco. In addition, all primary and secondary materials shall be integrally colored. The proposed plan provides the following materials and ratios: Elevations North South West East Material % s Precast Concrete Panels Glazing Metal Panels Total Applying the CGD architectural standards to the proposal, the glazing is considered a primary material ranging from 28%-56%. While not listed in the CGD standards, the Performance Standards within the Zoning Code list Architecturally precast textured concrete panels as a Class III material. The prefinished metal (6-7%) is an accent material. Metal panels are considered a Class I material when they cover an entire wall. With primary materials well below the 60% CGD standard, and no secondary materials, the proposed building materials do not meet the expectations of the CGD district. According to the project narrative, The integrally colored architectural precast is a high quality material, consistent with Class I building materials, and should not be confused with the raked concrete or painted wall panels The integrally colored architectural precast is an appropriate, durable non-degradable and low maintenance material which meets the requirements of MAC School and the intent of Section of the Eagan Zoning Ordinance. The applicant s narrative further describes why the integrally colored architectural precast panels are preferred over brick masonry or natural stone and provide a comparison to other new buildings within the Cedar Grove District. The acceptability of the proposed building materials is a policy matter to be determined by City officials. Signage The proposal includes both building mounted wall signs, a free-standing monument sign and directional signs. An existing billboard is proposed to be removed with the development of the site. Building Signs Wall signage is proposed on the north and south sides of the building. At the north end, the sign faces the parking lot and Silver Bell Road. The sign is located to the right of the cantilevered expanse of glass. On the south elevation, the sign is located to be visible from Highway 13.

11 Page 11 The CGD ordinance provides the following parameters for wall signage. Wall signs may be located within a 3 sign band, between 10 and 15 above ground. The proposal locates the wall signs at approximately 26, near the top of the two-story structure. Sign sizes appear to be below the allotted 1.5 sq. ft. per lineal foot of building frontage. The type of wall signage was not provided but should meet CGD standards. Final sign specifications including dimensions should be confirmed at the time of Sign Permit application. Freestanding Signs One free-standing sign is proposed, just west of the driveway entrance. The existing sign located east of the driveway is to be removed. The proposed sign location may conflict with a utility easement that extends along the front of the property. The monument sign location should be at least 10 from the property line and outside of the utility easement area. The applicant did not provide specifications for the monument sign other than it will be 45 sq. ft. in size. The base should be landscaped and constructed to match the principal building materials. The CGD district allows freestanding signs up to 12 in height. The sign base should be constructed of materials to match the principal building, with a minimum base height of 3 and a maximum sign area of 45 s.f. on one side. Design plans for the monument sign should be provided at the time of Sign Permit, and conformance with the CGD design standards confirmed at that time. Directional Signs Three directional signs are proposed, two along the western side of the main drive aisle and one in front of the new high school. The existing sign located east of the main drive aisle is to be removed. The applicant did not provide specifications for the directional signs other than they will be 6 sq. ft. in size. The CGD district allows directional signs up to 5 in height and no more than 6 sq. ft. in area. Directional signs must be setback at least two feet from right-of-way, lot lines and parking spaces and conform with the CGD design standards. Building Address Numbers Building address numbers should be installed consistent with the provisions of Section 2.78 of City Code. Mechanical Equipment/Trash Storage City Code requires a minimum 30 parapet for new buildings, and that mechanical units be placed at least 20 from the edge of the building. A Rooftop mechanical unit screen is shown on the Building Elevations; however, not in detail. The parapet height should be demonstrated on the permit plans, at the time of Building Permit, and placement of units 20 from the building edge. If these requirements alone do not fully screen the equipment, additional screening measures should be employed in accordance with City Code.

12 Page 12 Trash storage Trash is proposed to be stored inside the principal building, accessed through an exterior door to an access drive along the west side of the building. Landscaping The CGD zoning district includes specific design standards for landscaping including placement of trees every 25 where parking abuts the site perimeter, one overstory tree for every 500 sq. ft. of landscape area on the site, certain prohibited species and other species to be used only in certain circumstances, such as evergreen trees only in areas protected from winter wind conditions. Additionally, wherever a surface parking area faces a street frontage, such frontage should be screened with a decorative wall, railing, hedge, or a combination of these elements, to a minimum height of 2 ½ feet above the level of the parking lot, at the build-to line. The proposed Landscape Plan is acceptable with minor modifications. The Landscape Plan utilizes 6 species of shade/ornamental trees, 2 species of conifer, 5 shrub varieties and 5 species of perennials and ornamental grasses. The applicant should separate the shade and ornamental trees located within the plant schedule and verify quantities. The plan should be revised to screen the surface parking area as required near the proposed Colorado Spruce adjacent to Silver Bell Road. Throughout the site, the Colorado Spruce are shown to be installed in most cases 15 apart. The plan should be revised to accommodate the mature crown spread of these trees which is about 30 or utilize another spruce option such as Black Hills spruce. The Red Pine should also be replaced with a different species as urban conditions, wind and insects are problematic for the species. Staff suggests use of the Austrian Pine. The plantings should also meet minimum size requirements per City Code as follows: Deciduous overstory/shade 2 ½ caliper inches Deciduous understory/ornamental 1 ½ caliper inches Coniferous 6 Hedge and shrubs 3 The applicant s narrative describes the difficulty in meeting the CGD district requirements, specifically in relation to the number of trees required per the landscaped area, primarily due to the open space for recreational activities which is atypical for the CGD district. The proposed plan compliments the existing site and is typical of landscaping required on other properties outside of the CGD district. Lastly, overstory trees should be placed so as not to conflict with pole lighting or utilities such as hydrants. Overstory trees should be planted within parking islands wherever possible to maximize shade coverage of pavement areas. Tree Preservation The tree inventory submitted with this application indicates there are one hundred seventy-two (172) significant trees currently existing on site. According to the Tree Preservation Plan submitted, site improvement impacts will result in the removal of seventy-two (72) significant trees (41.9% of the total).

13 Page 13 Per the City of Eagan Tree Preservation Ordinance, allowable tree removal for this type of development proposal (single-lot, commercial) is 30% of the total significant trees. Because the proposed removal of significant trees is more than allowed without mitigation, required tree mitigation calculates to fifty (50) Category B trees (or an equivalent combination of Category A and/or C trees). The applicant has submitted a Tree Mitigation Plan that proposes nineteen (19) Category B trees be installed, which does not fulfill the required tree mitigation. The applicant should submit a revised Tree Mitigation Plan that fulfills the required tree mitigation amount of fifty (50) Category B trees (or an equivalent combination of Category A and/or C trees). Parks and Recreation This development is responsible for park and trail dedications. The park dedication was satisfied for what is presently Lot 1, with the development of the Tesseract school; however, the vacant lot has not satisfied park dedication. The pending dedications will be calculated based on actual construction plans at the time of Building Permit and collected prior to release of the Building Permit. Based on the 2015 Fee Schedule, the cash park dedication is anticipated to be $42,960 ($895/1000 s.f. of bldg. at 48,022 s.f. of building). Trail dedication is anticipated to be $8,195 (based on 6.5 net acres which includes the expansion lot and vacated Tesseract place). Financial Obligation At this time, there are no pending assessments on the parcels proposed for platting. Based upon a study by City staff of the financial obligations collected in the past and proposed use for the property, there are no outstanding charges to be collected at time of plat approval or connection to the City s utility system. SUMMARY/CONCLUSION The applicant is proposing a Rezoning and Preliminary Planned Development to allow construction of a two-story, 48,000 sq. ft., school within the Cedar Grove Redevelopment District. The proposal creates a school campus as an existing school is on the eastern side of the property, home to MAC (Mn Autism Center). The proposed development takes access from Silver Bell Road, and develops what is currently an Outlot and unplatted parcel. The majority of parking to support the school is provided within the front yard. The Site Plan provides for connections to the existing school within the site. The PD zoning provides flexibility in the application of zoning standards for mutual benefit. The developer is requesting some deviations to typical Code requirements such as for multiple buildings on one lot, setbacks exceeding the 0-10 build-to line, building materials and architecture, signage, landscaping and parking. The appropriateness of proposed deviations, as outlined in this report, is a policy matter to be determined by City officials. ACTIONS TO BE CONSIDERED To recommend approval of a Rezoning from CGD (Cedar Grove District) to PD (Planned Development) for proposed Lot 1, Block 1, Tesseract 2 nd Addition, located at 3800 Tesseract Place.

14 Page 14 To recommend approval of a Preliminary Planned Development for proposed Lot 1, Block 1, Tesseract 2 nd Addition, to allow a high school and school campus located at 3800 Tesseract Place. If approved, the following conditions shall apply: 1. A Preliminary Planned Development Agreement shall be executed. The following exhibits shall be made part of the Agreement: Preliminary Site Plan Preliminary Landscape Plan Preliminary Building Elevations Plan Preliminary Site Lighting Plan Preliminary Signage Plan 2. The property shall be platted. 3. This development shall be subject to a cash parks dedication payable at the time of Building Permit at the rates then in effect. 4. This development shall be subject to a cash trails dedication payable at the time Building Permit at the rates then in effect. 5. The applicant shall submit a revised Tree Mitigation Plan that fulfills the required tree mitigation amount of fifty (50) Category B trees (or an equivalent combination of Category A and/or C trees). 6. The construction of the school shall meet the sound attenuation requirements per the Metropolitan Council Transportation Policy Plan. 7. A Building Permit shall be obtained for the 7 chain link fence(s). 8. A Photometric Lighting Plan shall be provided at the time of Building Permit, illustrating levels of illumination in conformance with CGD standards. 9. The total light pole height and wall-mounted fixtures shall not exceed Rooftop mechanical units shall be shown on the Building Elevations at the time of building permit, and placement of units 20 from the building edge and parapet height shall be demonstrated on the permit plans. If these measures alone do not fully screen some equipment, additional screening measures shall be employed in accordance with City Code. 11. Detailed sign plans shall be submitted with the application for Sign Permits including dimensions, type of construction, and how the signs are to be lit. Conformance with City

15 Page 15 Code standards will be confirmed at that time. All signs shall require a Sign Permit prior to installation. 12. The type of Wall signage shall comply with City Code standards, located on the north and south elevations only. 13. The monument sign location shall be at least 10 from the property line and outside of the utility easement area. The base shall be landscaped and match the principal building materials. Design plans for the monument sign shall be provided at the time of Sign Permit and in conformance with the CGD design standards confirmed at that time. 14. The three directional signs shall conform with the CGD design standards. 15. Building address numbers shall be installed consistent with the provisions of Section 2.78 of City Code. 16. The Landscape Plan shall separate the shade and ornamental trees located within the plant schedule and quantities shall be verified. 17. The Landscape Plan key shall be revised to verify plantings meet minimum size requirements per City Code. 18. The Landscape Plan shall be revised to account for mature growth of the proposed conifers and replace the species with those better suited for the site. 19. The Landscape Plan shall be revised to enhance the screening of the parking lot per City Code. 20. Overstory trees shall be placed so as not to conflict with pole lighting or utilities such as hydrants. 21. Overstory trees shall be planted within parking islands wherever possible to maximize shade coverage of pavement areas. 22. A detailed grading, drainage, erosion and sediment control plan shall be prepared in accordance with current City standards and codes prior to issuance of any Building Permit. 23. All erosion/sediment control plans submitted for development and grading permits shall be prepared by a designer who has received current Minnesota Department of Transportation (MNDOT) training, or approved equal training as determined by the City Engineer in designing stormwater pollution prevention plans. 24. All personnel responsible for the construction and management of erosion/sediment control devices and the establishment of vegetation for the development, shall have

16 Page 16 received Erosion/Sediment Control site management certification through the University of Minnesota, or approved equal training as determined by the City Engineer. 25. All erosion control measures shall be installed and maintained in accordance with City code and engineering standards. 26. This development shall meet the City s Post Construction Stormwater Management Requirements (City Code 4.34) for stormwater management and surface water quality, including Runoff Rate Control, 1.1 Volume Control on the site s impervious surface area, and effective soil remediation for the site s disturbed soils that are to be revegetated. 27. Prior to receiving city approval to permit land disturbing activity, the applicant shall provide the City with soil boring logs from a minimum of four soil-borings within each of the proposed infiltration areas, extending a minimum of 10 below the bottom of the proposed infiltration feature, to evaluate and ensure suitability for infiltration. If the soil boring logs indicate incompatibility of existing sub-soil permeability with the submitted and reviewed design plans for meeting volume control requirements, the applicant shall revise the design and/or construction plans (e.g. over-excavation/soil-amendment depth, etc.) to ensure volume control requirements are fully met, in a manner acceptable to the City Engineer. 28. Prior to receiving city approval to permit land disturbing activity, the applicant shall provide construction details of proposed infiltration practices for City review, and acceptance by the City Engineer, (cross-sections, construction sequencing/protection, sizing/volume tables, details for inlets, overflows, outlets, maintenance access, soil amendment criteria, planting plans/details, etc.), to ensure infiltration practices are properly designed and constructed, and adequately protected during / after construction, to function as intended. These graphical details and notes shall be prominently included in all applicable plan sheets (e.g. Grading, Utility & Landscape plans). 29. Prior to receiving city approval to permit land disturbing activity, the applicant shall provide detailed Soil Management Strategies for City review, and acceptance by the City Engineer, that provide for assurances that at final grading the disturbed areas that are to be revegetated will have protected and/or restored soil permeability to non-compacted soil conditions, to comply with Volume Control requirements. These graphical details and notes shall be included in the Stormwater Management Plan and prominently included in all applicable plan sheets (e.g. Grading & Landscape plans). 30. Prior to receiving city approval to permit land disturbing activity, the applicant shall enter into a long-term stormwater management system maintenance agreement with the City, detailing the inspection and maintenance required to ensure proper operation and performance of the permanent stormwater management system, in a form acceptable to the City Attorney.

17 Page During infiltration practice over-excavation and sub-soil work, the applicant shall ensure that a Certified Soil Scientist will be present to verify and document that infiltration practice area sub-soils are suitable for a saturated condition infiltration rate of 0.8-inch per hour or greater (but less than 8.0-inch per hour). If the sub-soil infiltration rates are less than 0.8-inch per hour (or greater than 8.0-inch per hour), the applicant shall immediately notify the City Engineer and revise the volume control practice(s) as necessary (e.g. overexcavation/soil-amendment depth, etc.) to ensure volume control requirements are fully met. 32. Before the city issues a Certificate of Occupancy on the development site, the applicant shall provide the City Engineer as-built plans that demonstrate that all constructed stormwater conveyance structures, stormwater management facilities (forebay and infiltration practices) and soil management strategies conform to design and/or construction plans, as approved by the City. As-built volumes (for retention) shall be provided for the forebay and infiltration practices. Documentation shall be provided to verify soil management strategy compliance. The applicant shall submit to the City Engineer certification that the stormwater management facilities have been installed in accord with the plans and specifications approved. This certification shall be provided by a Professional Engineer licensed in the State of Minnesota. 33. This development shall provide hydrant spacing and locations in accordance with City Fire Department and Public Works standards. 34. The applicant shall submit a proposal/infrastructure plan to be approved by staff to provide telecommunications fiber to the premises (FTTP). This development should include the installation of fiber optic cable, or a conduit for future installation, in its construction plans at the time of Building Permit. 35. No Parking/Fire lane signage shall be installed in the parking lot and driveways, per Fire Department standards, to ensure emergency vehicle access. 36. This development shall be responsible for the acquisition of all regulatory agency permits required by the affected agency prior to building permit approval. To recommend approval of a Final Plat to create one lot upon 13 acres for proposed Lot 1, Block 1, Tesseract 2 nd Addition, located at 3800 Tesseract Place. If approved, the following conditions shall apply: 1. The developer shall comply with these standards conditions of plat approval as adopted by Council on February 2, 1993: B1, B2, B3, C1, C2, C4, E1, F1, G1 and H1 2. The property shall be platted.

Advisory Planning Commission September 27, 2016 Page 6 of 27

Advisory Planning Commission September 27, 2016 Page 6 of 27 Page 6 of 27 B. Quarry Road Addition Applicant Name: United Properties Development LLC, Rick McKelvey Location: 1555 Yankee Doodle Road; Application: Rezoning A Rezoning from A, Agriculture to PD, Planned

More information

Corridor Residential Traditional District Regulations City of St. Petersburg City Code Chapter 16, Land Development Regulations

Corridor Residential Traditional District Regulations City of St. Petersburg City Code Chapter 16, Land Development Regulations Section 16.20.060 - Corridor Residential Traditional Districts ( CRT ) Typical Buildings in the CRT District Sections: 16.20.060.1 Composition of Traditional Residential Corridors 16.20.060.2 Purpose and

More information

RECOMMENDATION: Staff recommends approval and provides the following motion for the commission s consideration:

RECOMMENDATION: Staff recommends approval and provides the following motion for the commission s consideration: PZ Case No. 17-09 Planning & Zoning Commission COMMUNITY DEVELOPMENT DEPARTMENT March 13, 2017 Subject: Consider making a recommendation on PZ Case No. 17-09; the site plans for Amega Garage Doors at 4901

More information

Neighborhood Suburban Single-Family District Regulations City of St. Petersburg City Code Chapter 16, Land Development Regulations

Neighborhood Suburban Single-Family District Regulations City of St. Petersburg City Code Chapter 16, Land Development Regulations Section 16.20.020 - Neighborhood Suburban Single-Family Districts ( NS ) Sections: Typical Block in a Neighborhood Suburban District 16.20.020.1 History and Composition of Suburban Neighborhoods 16.20.020.2

More information

ARTICLE 987. PD 987. PD 987 was established by Ordinance No , passed by the Dallas City Council on June 14, (Ord.

ARTICLE 987. PD 987. PD 987 was established by Ordinance No , passed by the Dallas City Council on June 14, (Ord. ARTICLE 987. PD 987. SEC. 51P-987.101. LEGISLATIVE HISTORY. PD 987 was established by Ordinance No. 30512, passed by the Dallas City Council on June 14, 2017. SEC. 51P-987.102. PROPERTY LOCATION AND SIZE.

More information

Neighborhood Traditional Single-Family District Regulations City of St. Petersburg City Code Chapter 16, Land Development Regulations

Neighborhood Traditional Single-Family District Regulations City of St. Petersburg City Code Chapter 16, Land Development Regulations Section 16.20.010 - Neighborhood Traditional Single-Family Districts ( NT ) Typical Houses in a Neighborhood Traditional District Typical Block in a Neighborhood Traditional District Common Features of

More information

Zoning Permits 11-1 ZONING PERMITS

Zoning Permits 11-1 ZONING PERMITS Zoning Permits 11-1 ZONING PERMITS (a) Building or structures shall be started, repaired, reconstructed, enlarged or altered only after a zoning permit has been obtained from the administrator and a building

More information

A. Applicability and Review Authority.

A. Applicability and Review Authority. 5.6 Development Plans Required for Architectural and Site Design Review in the TC: Town Center District, the R-U: Urban Residential District and the MU: Mixed Use District. Intent In order to: assure the

More information

Project Title: Major Site Review (SR16-06) for Ripon Gardens II Commercial

Project Title: Major Site Review (SR16-06) for Ripon Gardens II Commercial Planning Commission Staff Report Planning Commission Hearing November 14, 2016 Project Title: Major Site Review (SR16-06) for Ripon Gardens II Commercial Request: A request to develop a 15,996 square foot

More information

Fence and Wall Requirements

Fence and Wall Requirements Fence and Wall Requirements Definitions Decorative wall - A wall constructed of stone or other material erected for the sole purpose of providing a decorative and/or landscaped feature, and not to include

More information

Commercial Tax Abatement

Commercial Tax Abatement A confirmation letter is issued by the City upon receipt of this application. This application is not effective and not considered filed until the confirmation letter has been issued. Filing does not assure

More information

Corridor Residential Traditional District Regulations City of St. Petersburg City Code Chapter 16, Land Development Regulations

Corridor Residential Traditional District Regulations City of St. Petersburg City Code Chapter 16, Land Development Regulations 16.20.060 - Corridor Residential Traditional District ( CRT ) Figure REFERENCE Typical Buildings in the CRT District Sections: 16.20.060.1 Composition of Traditional Residential Corridors 16.20.060.2 Purpose

More information

Residential Design Standards Draft 9 August 2013

Residential Design Standards Draft 9 August 2013 RESIDENTIAL DESIGN STANDARDS ORDINANCE DRAFT 9 AUGUST 2013 17.25 Residential Design Standards 17.25.010 Purpose The purpose of this chapter is to establish minimum design standards for new residential

More information

SITE PLAN AND ARCHITECTURAL REVIEW APPLICATION

SITE PLAN AND ARCHITECTURAL REVIEW APPLICATION SITE PLAN AND ARCHITECTURAL REVIEW APPLICATION CITY OF GENEVA, NEW YORK The purpose of the site plan and architectural review process is to secure compliance with the City s Zoning Ordinance and to promote

More information

PC 10 05, Request for conditional use permit and and text amendment construct construct new North Education Education Center, Center, 5530 Zealand

PC 10 05, Request for conditional use permit and and text amendment construct construct new North Education Education Center, Center, 5530 Zealand PC 10 05, 05, Request for conditional use permit and text amendment to construct new North Education Center, 5530 Zealand Ave N Planning Commission October 5, 2010 General Information Planning Case: 10-05

More information

City of Valdosta Land Development Regulations

City of Valdosta Land Development Regulations Section 210-3 Urban Commercial Corridor Overlay District (A) Purpose. The purposes of the Urban Commercial Corridor Overlay District are to: (1) Promote the general health, safety, and welfare of the community.

More information

PLANNED UNIT DEVELOPMENT, PLANNING APPROVAL & SUBDIVISION STAFF REPORT Date: June 4, 2015

PLANNED UNIT DEVELOPMENT, PLANNING APPROVAL & SUBDIVISION STAFF REPORT Date: June 4, 2015 PLANNED UNIT DEVELOPMENT, PLANNING APPROVAL & SUBDIVISION STAFF REPORT Date: June 4, 2015 NAME SUBDIVISION NAME CC Williams Plant Subdivision CC Williams Plant Subdivision LOCATION CITY COUNCIL DISTRICT

More information

SECTION 5 EXCEPTIONS AND MODIFICATIONS

SECTION 5 EXCEPTIONS AND MODIFICATIONS Sec. 5-1 Walls and Fences. SECTION 5 EXCEPTIONS AND MODIFICATIONS All walls and fences shall be erected or constructed in compliance with the provisions of this section. These regulations shall not prohibit

More information

Submittal Requirements for Administrative Design Review of Signage

Submittal Requirements for Administrative Design Review of Signage CITY OF MERCER ISLAND, DEVELOPMENT SERVICES GROUP 9611 S.E. 36 ST., MERCER ISLAND, WA 98040 (206) 275-7605 FAX: (206) 275-7726 WWW.MERCERGOV.ORG Submittal Requirements for Administrative Design Review

More information

B-2 COMMUNITY COMMERCIAL BUSINESS DISTRICT. Uses allowed in the B-2 Community Commercial Business District are subject to the following conditions:

B-2 COMMUNITY COMMERCIAL BUSINESS DISTRICT. Uses allowed in the B-2 Community Commercial Business District are subject to the following conditions: SECTION 46-53.1 B-2 COMMUNITY COMMERCIAL BUSINESS DISTRICT A. PURPOSE The B-2 Community Commercial Business District is oriented toward retail, service businesses and multi-family residential development.

More information

5 February 12, 2014 Public Hearing APPLICANT AND PROPERTY OWNER: ERIK HOMES, L.L.C.

5 February 12, 2014 Public Hearing APPLICANT AND PROPERTY OWNER: ERIK HOMES, L.L.C. 5 February 12, 2014 Public Hearing APPLICANT AND PROPERTY OWNER: ERIK HOMES, L.L.C. STAFF PLANNER: Kristine Gay REQUEST: Special Exception for Alternative Compliance to the Oceanfront Resort District Form-Based

More information

# 17 ) UN DESERT GREEN FARMS SPECIAL USE PERMIT EXTENSION OF TIME PUBLIC HEARING

# 17 ) UN DESERT GREEN FARMS SPECIAL USE PERMIT EXTENSION OF TIME PUBLIC HEARING # 17 ) UN-101-14 DESERT GREEN FARMS SPECIAL USE PERMIT EXTENSION OF TIME PUBLIC HEARING STAFF REPORT To: Planning Commission Meeting date: December 9, 2015 Item: UN-101-14 Prepared by: Robert Eastman GENERAL

More information

# Mercyhealth Hospital Project Review for Planning and Zoning Commission

# Mercyhealth Hospital Project Review for Planning and Zoning Commission #2017-38 Mercyhealth Hospital Project Review for Planning and Zoning Commission Meeting Dates: December 6, 2017 and January 3, 2018 Requests: 1. Preliminary Planned Unit Development and 2. Special Use

More information

CITY OF WINTER PARK SETBACK/COVERAGE WORKSHEET GUIDE FOR SINGLE FAMILY ZONING

CITY OF WINTER PARK SETBACK/COVERAGE WORKSHEET GUIDE FOR SINGLE FAMILY ZONING CITY OF WINTER PARK SETBACK/COVERAGE WORKSHEET GUIDE FOR SINGLE FAMILY ZONING See Setback/Coverage Worksheet & Criteria: Pages 1-4 & Accessory Structure Guide Step 1 Step 2 Step 3 Step 4 Step 5 Step 6

More information

Neighborhood Suburban Single-Family District Regulations City of St. Petersburg City Code Chapter 16, Land Development Regulations

Neighborhood Suburban Single-Family District Regulations City of St. Petersburg City Code Chapter 16, Land Development Regulations 16.20.020 Neighborhood Suburban Single-Family District ( NS ) Figure REFRENCE Typical Houses in Neighborhood Suburban 1 Figure REFRENCE Typical Block in a Neighborhood Suburban District Sections: 16.20.020.1

More information

CHAPTER 13 R-5 MANUFACTURED MOBILE HOME PARK RESIDENTIAL DISTRICT

CHAPTER 13 R-5 MANUFACTURED MOBILE HOME PARK RESIDENTIAL DISTRICT 15.1300 CHAPTER 13 R-5 MANUFACTURED MOBILE HOME PARK RESIDENTIAL DISTRICT 15.1301 SECTION 13.01 STATEMENT OF PURPOSE To provide for manufactured home park development, of long-term duration of stay, in

More information

MIAMI 21 ARTICLE 5. SPECIFIC TO ZONES PUBLIC HEARING-FIRST READING TABLE OF CONTENTS

MIAMI 21 ARTICLE 5. SPECIFIC TO ZONES PUBLIC HEARING-FIRST READING TABLE OF CONTENTS TABLE OF CONTENTS 5.1 Generally 5.2 Natural Transect Zone (T1) and Rural Transect Zones (T2) (Reserved) 5.3 Sub-Urban Transect Zones (T3) 5.4 General Urban Transect Zones (T4) 5.5 Urban Center Transect

More information

Ordinance No Lot Surface Drainage

Ordinance No Lot Surface Drainage Ordinance No. 35-2008 - Lot Surface Drainage The Township has adopted a new Lot Surface Drainage Ordinance which amends Chapter 170, Article IX, Subdivision and Site Plan Review by adding a new Section

More information

GRADING & DRAINAGE PERMIT SOIL EROSION AND SEDIMENTATION CONTROL PERMIT PROGRAM OVERVIEW

GRADING & DRAINAGE PERMIT SOIL EROSION AND SEDIMENTATION CONTROL PERMIT PROGRAM OVERVIEW GRADING & DRAINAGE PERMIT SOIL EROSION AND SEDIMENTATION CONTROL PERMIT PROGRAM OVERVIEW Chapter 8 Building and Building Regulations, Article XIII Grading and Drainage and Article XV Soil Erosion and Sedimentation

More information

11.0 Commercial Infill

11.0 Commercial Infill 11.0 Commercial Infill 11.1 INTRODUCTION Infill is the process of building a new structure on a vacant site within an existing neighborhood. These Infill guidelines are also applicable to the review of

More information

Request Conditional Use Permit (Automobile Repair Garage) Staff Planner Jimmy McNamara

Request Conditional Use Permit (Automobile Repair Garage) Staff Planner Jimmy McNamara Applicant Property Owner Sarrow One, LLC Public Hearing December 14, 2016 City Council Election District Princess Anne Agenda Item 13 Request Conditional Use Permit (Automobile Repair Garage) Staff Planner

More information

r e s i d e n t i a l o u t s i d e v i l l a g e c e n t e r

r e s i d e n t i a l o u t s i d e v i l l a g e c e n t e r N e w A l b a n y, O h i o r e s i d e n t i a l o u t s i d e v i l l a g e c e n t e r D e s i g n G u i d e l i n e s & R e q u i r e m e n t s s e c t i o n 5 I. Overview This section applies to all

More information

DEPARTMENT OF PLANNING JEFFERSON PARISH, LOUISIANA

DEPARTMENT OF PLANNING JEFFERSON PARISH, LOUISIANA DEPARTMENT OF PLANNING JEFFERSON PARISH, LOUISIANA DESIGN REVIEW REPORT DOCKET NO: SUMMAR NO.: : : Paul D. Johnston AT LARGE: A: Chris Roberts B: Elton M. Lagasse ADVERTISING DATES: PAB PUBLIC HEARING:

More information

City of Richmond Zoning Ordinance Page 12-1

City of Richmond Zoning Ordinance Page 12-1 ARTICLE 12 BUILDING DESIGN AND COMPOSITION Section 12.01 Purpose. High quality architectural design and building composition are important elements in reinforcing a comfortable, human-scale environment,

More information

Public Hearing January 13, Request Conditional Use Permit (Auto Repair Garage) Staff Planner Carolyn A.K. Smith

Public Hearing January 13, Request Conditional Use Permit (Auto Repair Garage) Staff Planner Carolyn A.K. Smith Applicant Property Owner Holland Century Associates, LLP Public Hearing January 13, 2016 Request Conditional Use Permit (Auto Repair Garage) Staff Planner Carolyn A.K. Smith Location 3949 Holland Road

More information

INTENT OBJECTIVES HISTORIC DESIGNATIONS

INTENT OBJECTIVES HISTORIC DESIGNATIONS TOWN OF LOS GATOS RESIDENTIAL DEVELOPMENT STANDARDS FOR ALL SINGLE FAMILY AND TWO-FAMILY DWELLINGS IN ALL ZONES EXCEPT THE RESOURCE CONSERVATION AND HILLSIDE RESIDENTIAL ZONES INTENT These development

More information

# 5 ) UN THREE CUPS YARD NORTH AMERICA CULTIVATION FACILITY SPECIAL USE PERMIT PUBLIC HEARING

# 5 ) UN THREE CUPS YARD NORTH AMERICA CULTIVATION FACILITY SPECIAL USE PERMIT PUBLIC HEARING # 5 ) UN-74-16 THREE CUPS YARD NORTH AMERICA CULTIVATION FACILITY SPECIAL USE PERMIT PUBLIC HEARING STAFF REPORT To: Planning Commission Meeting date: November 9, 2016 Item: UN-74-16 Prepared by: Marc

More information

a. Structures subject to section Architectural & Site Design Standards must comply with the following additional fencing standards:

a. Structures subject to section Architectural & Site Design Standards must comply with the following additional fencing standards: 5.03.02 Fences and Walls A. All districts. 1. Whenever a property owner elects to construct a chain link fence, pursuant to the provisions herein, adjacent to an arterial or collector road in the urban

More information

Section 1 Non-Conforming Structures and Uses Allowed to Continue. 12

Section 1 Non-Conforming Structures and Uses Allowed to Continue. 12 CHAPTER 3 NONCONFORMITIES Section 1 Non-Conforming Structures and Uses Allowed to Continue. 12 Section 2 Discontinuance 12 Section 3 Change of Use... 12 Section 4 Residential Alterations 12 Section 5 Restoration..

More information

The requirements set forth in this Section shall govern the construction and/or installation of all Renewable Energy Systems:

The requirements set forth in this Section shall govern the construction and/or installation of all Renewable Energy Systems: CHAPTER 408: RENEWABLE ENERGY SYSTEMS Renewable Energy Systems are accessory uses which include Solar Energy Systems and Wind Energy Systems that provide supplemental energy to residential, nonresidential,

More information

BULLARD STREET HEYWOOD AVENUE 40' PUBLIC R/W 40' PUBLIC R/W MARKED CROSSWALK FUTURE B.O.C. LANDSCAPE SCREENING (USDG U-03 RESIDENTIAL WIDE)

BULLARD STREET HEYWOOD AVENUE 40' PUBLIC R/W 40' PUBLIC R/W MARKED CROSSWALK FUTURE B.O.C. LANDSCAPE SCREENING (USDG U-03 RESIDENTIAL WIDE) DEVELOPMENT STANDARDS A. General Provisions 1. These Development Standards form a part of the Rezoning Plan associated with the Rezoning Petition filed by CapRock, LLC ( Petitioner ) to accommodate the

More information

Canal Winchester. Town Hall 10 North High Street Canal Winchester, OH Meeting Minutes. Monday, November 13, :00 PM

Canal Winchester. Town Hall 10 North High Street Canal Winchester, OH Meeting Minutes. Monday, November 13, :00 PM Canal Winchester Town Hall 10 North High Street Canal Winchester, OH 43110 Meeting Minutes Monday, November 13, 2017 7:00 PM Planning and Zoning Commission Bill Christensen Chairman Michael Vasko Vice

More information

PLANNED UNIT DEVELOPMENT & SUBDIVISION STAFF REPORT Date: July 11, 2013

PLANNED UNIT DEVELOPMENT & SUBDIVISION STAFF REPORT Date: July 11, 2013 PLANNED UNIT DEVELOPMENT & SUBDIVISION STAFF REPORT Date: July 11, 2013 SUBDIVISION NAME DEVELOPMENT NAME LOCATION Northside LTD/Joint Venture Subdivision, Resubdivision of and Addition to Lot 3A Northside

More information

ARTICLE 5 RESIDENTIAL MANUFACTURED HOME DISTRICT. Description and Purpose CHARTER TOWNSHIP OF BRIGHTON ZONING ORDINANCE

ARTICLE 5 RESIDENTIAL MANUFACTURED HOME DISTRICT. Description and Purpose CHARTER TOWNSHIP OF BRIGHTON ZONING ORDINANCE ARTICLE RESIDENTIAL MANUFACTURED HOME DISTRICT This Article was reviewed and approved by the Michigan Department of Consumer and Industry Services, Corporation and Securities Bureau, Manufactured Home

More information

CITY OF ST. PETERSBURG PLANNING & ECONOMIC DEVELOPMENT DEPT

CITY OF ST. PETERSBURG PLANNING & ECONOMIC DEVELOPMENT DEPT CITY OF ST. PETERSBURG PLANNING & ECONOMIC DEVELOPMENT DEPT 2016 Residential LDR Update DETAILED AGENDA Workshop #1 March 08, 2016 Main Library 3745 9 th Ave N; 6 PM-8 PM 1. Introduction (15 minutes) Overview

More information

City of North Miami Beach, Florida COMMUNITY DEVELOPMENT DEPARTMENT

City of North Miami Beach, Florida COMMUNITY DEVELOPMENT DEPARTMENT City of North Miami Beach, Florida COMMUNITY DEVELOPMENT DEPARTMENT TO: Planning and Zoning Board FROM: Carlos M. Rivero, City Planner DATE: August 10, 2015 RE: Storage Facility P&Z ITEM # 15-010 OWNER

More information

CITY OF CEDAR FALLS DEPARTMENT OF DEVELOPMENTAL SERVICES INSPECTION SERVICES DIVISION PHONE Residential Accessory Structures

CITY OF CEDAR FALLS DEPARTMENT OF DEVELOPMENTAL SERVICES INSPECTION SERVICES DIVISION PHONE Residential Accessory Structures CITY OF CEDAR FALLS DEPARTMENT OF DEVELOPMENTAL SERVICES INSPECTION SERVICES DIVISION PHONE - 268-5161 Residential Accessory Structures This information has been compiled for the benefit of any person

More information

Notwithstanding article VII of this chapter, the following conditional uses may be permitted in the planned mixed use development (PMUD) zone:

Notwithstanding article VII of this chapter, the following conditional uses may be permitted in the planned mixed use development (PMUD) zone: DIVISION 14. - PLANNED MIXED USE DEVELOPMENT (PMUD) Sec. 78-1021. - Purpose. The town is a community with a rich tradition of mixed use neighborhoods and a paucity of land area dedicated for large commercial,

More information

4) Garage placement must be in compliance with Sec. 6.3.G.2 below.

4) Garage placement must be in compliance with Sec. 6.3.G.2 below. 6.3 SMALL TOWN CHARACTER OVERLAY DISTRICT 6.3.1 Small Town Character Overlay District Article 6 / Overlay Districts A) Purpose The purpose and intent of the Small Town Character Overlay District is to

More information

SIGNS (OR )

SIGNS (OR ) 1138.00 SIGNS (OR2016-8-68) 1138.10 Purpose And Scope: The purpose and scope of this section is to: A) Foster a positive business atmosphere by permitting every business to efficiently and effectively

More information

FENCE PERMIT APPLICATION

FENCE PERMIT APPLICATION Department of Building, Zoning & Housing 26789 Highland Road Richmond Heights, Ohio 44143-1429 216-383-6312 Fax: 216-383-6319 richmondheightsohio.org FENCE PERMIT APPLICATION LOCATION OF JOB LOT # SUBDIVISION

More information

Plan Name Plan No. Submitting Firm Contact Engineer. Review Date ESI Team ENGINEERS AND SURVEYORS INSTITUTE PEER REVIEW CHECKLIST CITY OF ALEXANDRIA

Plan Name Plan No. Submitting Firm Contact Engineer. Review Date ESI Team ENGINEERS AND SURVEYORS INSTITUTE PEER REVIEW CHECKLIST CITY OF ALEXANDRIA EROSION AND SEDIMENT CONTROL CHECKLIST (E&S) VIRGINIA EROSION AND SEDIMENT CONTROL HANDBOOK (1 of 2) Item # Description OK NO N/A 1 Limits of clearing and grading match on all appropriate sheets 2 Construction

More information

Residential Uses in the Historic Village Core

Residential Uses in the Historic Village Core BLACK DIAMOND DESIGN GUIDLINES for Residential Uses in the Historic Village Core Adopted June 18, 2009 Introduction and Purpose These guidelines are intended to guide infill development within the Historic

More information

ONLY ONLY BUILDING AND PARKING ENVELOPE RAMP STAIRS NEW SURFACE PARKING PROPOSED HOTEL PROPOSED TWO STORY PARKING STRUCTURE NEW SURFACE PARKING

ONLY ONLY BUILDING AND PARKING ENVELOPE RAMP STAIRS NEW SURFACE PARKING PROPOSED HOTEL PROPOSED TWO STORY PARKING STRUCTURE NEW SURFACE PARKING LOCATION MAP SITE DEVELOPMENT DATA: --ACREAGE: ± 5. ACRES -- ZONING: MUDD-O -- USES: UP TO TWO () HOTELS WITH UP TO 70 ROOMS (APPROXIMATELY 00 ROOMS IN THE EXISTING HOTEL ON THE SITE, AND UP TO 70 ROOMS

More information

Architectural Review Board Report

Architectural Review Board Report Architectural Review Board Report Architectural Review Board Meeting: December 15, 2014 Agenda Item: 7.5 To: From: Subject: Architectural Review Board Steve Traeger, Principal Urban Designer Grace Page,

More information

LDR RESIDENTIAL LAND DEVELOPMENT REGULATIONS (LDRs) CODE UPDATE D.R.C. June 7, 2017

LDR RESIDENTIAL LAND DEVELOPMENT REGULATIONS (LDRs) CODE UPDATE D.R.C. June 7, 2017 LDR 2017-01 RESIDENTIAL LAND DEVELOPMENT REGULATIONS (LDRs) CODE UPDATE D.R.C. June 7, 2017 SECTION NO. SECTION TITLE COMPLEXITY DESCRIPTION 1. 16.20.010.5. Problem Statement: Concerns have been expressed

More information

ARCHITECTURAL GUIDELINES HOLLYBROOK COVES HOA

ARCHITECTURAL GUIDELINES HOLLYBROOK COVES HOA ARCHITECTURAL GUIDELINES HOLLYBROOK COVES HOA I. General A. PURPOSE This document describes Section 5.03(c) of the Hollybrook Coves Homeowners Association By-Laws charging the Hollybrook Coves HOA with

More information

FENCES. This hand out is for REFERENCE ONLY. For more details see specific code sections.

FENCES. This hand out is for REFERENCE ONLY. For more details see specific code sections. Village of Vernon Hills Community Development Department 290 Evergreen Drive, Vernon Hills, IL 60061 Phone 847-367-3704 - Fax 847-367-2541 - http:// www.vernonhills.org FENCES This hand out is for REFERENCE

More information

Fence, Wall & Column Information Packet

Fence, Wall & Column Information Packet FENCE INFORMATION FROM SECTION 9.13 OF THE PINEHURST DEVELOPMENT ORDINANCE: (1) The purpose of this Subsection is to allow fences within districts which are architecturally compatible with each other,

More information

Commercial Medical Marijuana Operation Design Guidelines

Commercial Medical Marijuana Operation Design Guidelines City of Coalinga Community Development Department Commercial Medical Marijuana Operation Design Guidelines The provisions set forth in this document identify the desired level of design quality for all

More information

Light Industrial (I)

Light Industrial (I) C H A P T E R 32 Light Industrial (I) Sections 17.32.01 Purpose 17.32.02 Permitted Uses 17.32.03 Accessory Uses 17.32.04 Conditional Uses 17.32.05 Site Plan Review 17.32.06 Development Standards 17.32.07

More information

-01k( Rec.by:DZ. ARTICLE IX - STANDARDS FOR TELECOMMUNICATIONS TOWERS AND ANTENNAS. Section Intent

-01k( Rec.by:DZ. ARTICLE IX - STANDARDS FOR TELECOMMUNICATIONS TOWERS AND ANTENNAS. Section Intent ARTICLE IX - STANDARDS FOR TELECOMMUNICATIONS TOWERS AND ANTENNAS Section 900 - Intent The intent and purpose of this Article is to establish general guidelines for the sitting of commercial telecommunications

More information

ARTICLE 10 MANUFACTURED HOME DEVELOPMENT STANDARDS

ARTICLE 10 MANUFACTURED HOME DEVELOPMENT STANDARDS ARTICLE 10 MANUFACTURED HOME DEVELOPMENT STANDARDS 10.000 Overview. This article contains the standards of development for manufactured housing placed on individual lots and in manufactured home parks

More information

#21 ) FDP Covenant Group FINAL DEVELOPMENT PLAN

#21 ) FDP Covenant Group FINAL DEVELOPMENT PLAN STAFF REPORT #21 ) FDP-04-16 Covenant Group FINAL DEVELOPMENT PLAN To: Planning Commission Meeting date: October 12, 2016 Item: FDP-04-16 Prepared by: Robert Eastman GENERAL INFORMATION: Applicant: Owner:

More information

Garage Construction. Permit Guide. Development Center. General Information. Zoning Ordinance Requirements. Building Code Requirements

Garage Construction. Permit Guide. Development Center. General Information. Zoning Ordinance Requirements. Building Code Requirements General Information Site Card. Before starting construction, post the site card (issued by the City) in a front window visible from the street. Miss Dig. Before you dig, call Miss Dig at 800.482.7171 This

More information

RESIDENTIAL FENCE STANDARDS

RESIDENTIAL FENCE STANDARDS RESIDENTIAL FENCE STANDARDS 3.5200 PURPOSE The standards set forth in this Section are established to encourage the suitable use of land while advancing the following goals of the City: to preserve privacy,

More information

CHAPTER 7 - INFRASTRUCTURE INSPECTION AND ACCEPTANCE... 2

CHAPTER 7 - INFRASTRUCTURE INSPECTION AND ACCEPTANCE... 2 CHAPTER 7 - INFRASTRUCTURE INSPECTION AND ACCEPTANCE... 2 7.1. GENERAL.... 2 7.1.1. Inspection Restriction Dates.... 2 7.1.2. Complete Improvements.... 2 7.1.3. Public Improvements.... 2 7.1.4. Warranty

More information

ORDINANCE NO. _5063. The Board of Supervisors of the County of Santa Cruz ordains as follows: SECTION I

ORDINANCE NO. _5063. The Board of Supervisors of the County of Santa Cruz ordains as follows: SECTION I ORDINANCE NO. _5063 AN ORDINANCE AMENDING SUBDIVISION (d) OF SECTION 13.10.170 AND SECTION 13.10.400, AND ADDING COUNTY CODE SECTIONS 13.10.444, 13.10.445, 13.10.446 AND 13.10.447, ESTABLISHING A PLEASURE

More information

HISTORIC DISTRICT BOARD OF REVIEW SAVANNAH HISTORIC DISTRICT Instructions for Certificate of Appropriateness Application

HISTORIC DISTRICT BOARD OF REVIEW SAVANNAH HISTORIC DISTRICT Instructions for Certificate of Appropriateness Application HISTORIC DISTRICT BOARD OF REVIEW SAVANNAH HISTORIC DISTRICT Instructions for Certificate of Appropriateness Application This document is for information purposes only and does not need to be submitted

More information

3 PROJECT DESCRIPTION

3 PROJECT DESCRIPTION 3.1 PROJECT OVERVIEW 3 PROJECT DESCRIPTION The Rocklin 60 project (proposed project) includes the subdivision of 56.9 acres of land, construction of 179 single-family, detached dwelling units, and installation

More information

PART R3-L ZONE, LOW DENSITY MULTIPLE DWELLING DISTRICT

PART R3-L ZONE, LOW DENSITY MULTIPLE DWELLING DISTRICT PART 3.2 - R3-L ZONE, LOW DENSITY MULTIPLE DWELLING DISTRICT Uses 1 The following uses are permitted: (a) single family dwellings; (b) two family dwellings; (c) multiple dwellings; (d) churches; (e) public

More information

ARTICLE VIII. (SF-A, SF-TH) SINGLE-FAMILY ATTACHED AND TOWNHOUSE RESIDENTIAL DISTRICTS

ARTICLE VIII. (SF-A, SF-TH) SINGLE-FAMILY ATTACHED AND TOWNHOUSE RESIDENTIAL DISTRICTS (Ord. No. 2835; 07/01/03) SECTION A. PURPOSE. ARTICLE VIII. (SF-A, SF-TH) SINGLE-FAMILY ATTACHED AND TOWNHOUSE RESIDENTIAL DISTRICTS 1. The (SF-A, SF-TH) Single-Family Residential Districts are intended

More information

(b) Within the front setback area, no wall, fence or hedge shall exceed three feet six inches (3'6").

(b) Within the front setback area, no wall, fence or hedge shall exceed three feet six inches (3'6). 16.11.135: REQUIREMENTS FOR FENCES AND WALLS: (1) Setback Area Defined: The term "front setback area" for the purpose of this title shall refer to the setback area (as required by this title) along any

More information

STORMWATER AND EROSION CONTROL PERMIT

STORMWATER AND EROSION CONTROL PERMIT STORMWATER MANAGEMENT AND EROSION CONTROL PERMIT INSTRUCTIONS AND INFORMATION Any project that involves the disturbance of ANY quantity of land requires the applicant to receive approval for the project

More information

APPLICATION FOR PUBLIC INFRASTRUCTURE PERMIT

APPLICATION FOR PUBLIC INFRASTRUCTURE PERMIT APPLICATION FOR PUBLIC INFRASTRUCTURE PERMIT Engineering Division 550 Landa Street New Braunfels, Texas 78130 (830) 221-4020 1. Subdivision Plat Name: Location Description/ Nearest Intersection: Acreage:

More information

CITY OF ASTORIA PUBLIC WORKS ENGINEERING DIVISION ENGINEERING DESIGN STANDARDS FOR IN-FILL DEVELOPMENT

CITY OF ASTORIA PUBLIC WORKS ENGINEERING DIVISION ENGINEERING DESIGN STANDARDS FOR IN-FILL DEVELOPMENT CITY OF ASTORIA PUBLIC WORKS ENGINEERING DIVISION ENGINEERING DESIGN STANDARDS FOR IN-FILL DEVELOPMENT Adopted by City Council: May 21, 2007 X:\General Eng\DESIGN STANDARDS\Engineering Design Standards

More information

Commercial Remodel Permit

Commercial Remodel Permit Commercial Remodel Permit Zoning requirements Staff recommends always verifying the zoning requirements for your project before deciding to build. Warrensburg has eleven separate zoning districts, each

More information

* Car washes and automobile service stations provided that:

* Car washes and automobile service stations provided that: 10. B-3 General Commercial District A. Intent The intent of the B-3 General Business District is to create an area to serve the commercial and service needs of the general population. The objective is

More information

City of Bullhead City Development Services/Public Works. Permit Submittal Requirements FENCES

City of Bullhead City Development Services/Public Works. Permit Submittal Requirements FENCES City of Bullhead City Development Services/Public Works Permit Submittal Requirements FENCES Contact Information: Building Division (928) 763-0124 Planning & Zoning Division (928) 763-0123 Engineering

More information

MIAMI 21 AS ADOPTED JANUARY 2011

MIAMI 21 AS ADOPTED JANUARY 2011 TABLE OF CONTENTS 5.1 Generally 5.2 Natural Transect Zones (T1) and Rural Transect Zones (T2) 5.3 Sub-Urban Transect Zones (T3) 5.4 General Urban Transect Zones (T4) 5.5 Urban Center Transect Zones (T5)

More information

TOWNSHIP OF MOON ORDINANCE NO. 585

TOWNSHIP OF MOON ORDINANCE NO. 585 OFFICIAL TOWNSHIP OF MOON ORDINANCE NO. 585 AN ORDINANCE OF THE TOWNSHIP OF MOON, ALLEGHENY COUNTY, PENNSYLVANIA, AMENDING CHAPTER 208 OF THE MOON TOWNSHIP CODE OF ORDINANCES, ZONING, TO ESTABLISH THE

More information

REQUEST FOR ACTION CHASKA CITY COUNCIL DECEMBER 7, 2015

REQUEST FOR ACTION CHASKA CITY COUNCIL DECEMBER 7, 2015 REQUEST FOR ACTION CHASKA CITY COUNCIL DECEMBER 7, 2015 Agenda Item No. 12 Subject: Applicant: Locations: Goodwill and Ridgeview Medical Plaza - Concept Plan Wellington Management 3000 Hundertmark Road

More information

Department of Planning and Community Services Recommendation. Community Zoning Board Recommendations February 21, 2012

Department of Planning and Community Services Recommendation. Community Zoning Board Recommendations February 21, 2012 20112-0012 SFC PETITION TO AMEND THE FULTON COUNTY ZONING RESOLUTION TO ADD ARTICLE 12N FULTON INDUSTRIAL BUSINESS DISTRICT OVERLAY DISTRICT Department of Planning and Community Services Recommendation

More information

CONSTRUCTION SURVEY. Construction survey includes personnel, equipment, and supplies required for, but not limited to, the following:

CONSTRUCTION SURVEY. Construction survey includes personnel, equipment, and supplies required for, but not limited to, the following: CONSTRUCTION SURVEY PART 1 - GENERAL 1.01 SECTION INCLUDES Construction survey includes personnel, equipment, and supplies required for, but not limited to, the following: A. Construction Survey: 1. Project

More information

# 7 ) UN MY PLACE HOTEL SPECIAL USE PERMIT PUBLIC HEARING

# 7 ) UN MY PLACE HOTEL SPECIAL USE PERMIT PUBLIC HEARING # 7 ) UN-53-16 MY PLACE HOTEL SPECIAL USE PERMIT PUBLIC HEARING STAFF REPORT To: Planning Commission Meeting date: September 14, 2016 Item: UN-53-16 Prepared by: Marc Jordan GENERAL INFORMATION: Applicant:

More information

ADMINISTRATIVE SITE PLAN REVIEW FOR SINGLE- AND TWO-FAMILY DWELLINGS AND MULTIPLE-FAMILY DWELLINGS HAVING THREE OR FOUR DWELLING UNITS

ADMINISTRATIVE SITE PLAN REVIEW FOR SINGLE- AND TWO-FAMILY DWELLINGS AND MULTIPLE-FAMILY DWELLINGS HAVING THREE OR FOUR DWELLING UNITS Community Planning and Economic Development Development Services Division 250 South 4 th Street, Room 300 Minneapolis MN 55415-1316 612-673-3000 ADMINISTRATIVE SITE PLAN REVIEW FOR SINGLE- AND TWO-FAMILY

More information

ARTICLE XII RECREATIONAL VEHICLE PARK REGULATIONS

ARTICLE XII RECREATIONAL VEHICLE PARK REGULATIONS ARTICLE XII RECREATIONAL VEHICLE PARK REGULATIONS ARTICLE XII RECREATIONAL VEHICLE PARK REGULATIONS Section 1201 Applicability For the purpose of this Article, recreation vehicles and recreational vehicle

More information

SIGN AREA (SQ. FT.): SIGN DIMENSIONS: STREET FRONTAGE OF PROPERTY (ft):

SIGN AREA (SQ. FT.): SIGN DIMENSIONS: STREET FRONTAGE OF PROPERTY (ft): JOB SITE ADDRESS: CITY OF CHELAN SIGN PERMIT APPLICATION FORM Planning and Community Development P.O. Box 1669, 135 E. Johnson Chelan, WA 98816 (509) 682-8017 Fax: (509) 682-8050 DATE APPLIED: PERMIT NO.:

More information

Section , Article 4 of the Zoning Ordinance December 14, 2012 Page 1 of 8

Section , Article 4 of the Zoning Ordinance December 14, 2012 Page 1 of 8 Page 1 of 8 5.37-1 Fence Regulations (Amended Ordinance 1598 12/23/12) A. Intent: The intent of this section is to provide reasonable regulations for fence installation while allowing property owners the

More information

Franklin County Communique to the Planning Board

Franklin County Communique to the Planning Board Franklin County Communique to the Planning Board PETITIONER(S): Name of Petitioner: Carolina Solar Energy II, LLC Address: 400 W. Main St. Suite 503 City/State/Zip: Durham, NC 27701 LOCATION: REQUEST FOR

More information

8.6 EXTERIOR LIGHTING

8.6 EXTERIOR LIGHTING Sec. 8.5.5 / Operational/Physical Compatibility 8.6 EXTERIOR LIGHTING 8.6.1 Purpose and Intent The provision of outdoor lighting heightens nighttime safety and visibility, and is used to enhance the security

More information

TES Industrial Development SW ¼ SEC Lacombe County Outline Plan

TES Industrial Development SW ¼ SEC Lacombe County Outline Plan TES Industrial Development Lacombe County Outline Plan 112849297 June 2012 am v:\1128\active\112849297\07_reports_studies\rpt_tes_20120508.doc i Table of Contents 1.0 INTRODUCTION... 1 1.1 PURPOSE... 1

More information

CEMENTITIOUS SIDING NORMAN BRICK VENEER SET AT 1/3 COURSING CEMENTITIOUS LAP SIDING (PAINT TO MATCH BRICK COLOR) CEMENTITIOUS SIDING ALUMINUM CANOPY

CEMENTITIOUS SIDING NORMAN BRICK VENEER SET AT 1/3 COURSING CEMENTITIOUS LAP SIDING (PAINT TO MATCH BRICK COLOR) CEMENTITIOUS SIDING ALUMINUM CANOPY 10/24/2016 1:19:25 PM P:\16proj\16038_Univ Exec Park\4_Working Directory\Revit\Univ Exec Park - SD_05.rvt SIGNAGE BAND CEMENTITIOUS TRIM BAND BREEZEWAY BUILDING ACCESS CEMENTITIOUS LAP SIDING (PAINT TO

More information

COLFAX MAINSTREET OVERLAY DISTRICT

COLFAX MAINSTREET OVERLAY DISTRICT COLFAX MAINSTREET OVERLAY DISTRICT Ordinance No. 2005-09 Effective Date: April 30, 2005 City of Aurora Planning Department 15151 E. Alameda Pkwy 2nd Floor Aurora, CO 80012 Phone: 303-739-7250 Fax: 303-739-7268

More information

Holdener Farm Area P.U.D. Enumclaw,Washington DESIGN STANDARDS PHASE ONE

Holdener Farm Area P.U.D. Enumclaw,Washington DESIGN STANDARDS PHASE ONE Holdener Farm Area P.U.D. Enumclaw,Washington DESIGN STANDARDS PHASE ONE As approved by City Council June 24, 2002 City of Enumclaw Holdener Farm Area PUD Design Guidelines Phase One TABLE OF CONTENTS

More information

Staff Report. Application: A Application #: A Parcel number:

Staff Report. Application: A Application #: A Parcel number: Staff Report Application: 2016 20A Application #: 2016 20A Parcel number: 87-029-1110 Applicants: Bob and Carol Faye Muller on property described as: All that part of Government Lot 1, Section 29 Township

More information

Marbella Isles Homeowners Association, Inc.

Marbella Isles Homeowners Association, Inc. REQUEST FOR ARCHITECTURAL REVIEW Please Note: There is a $25.00 non-refundable processing fee for all requests. The application will not be processed if it is not included with application. Make check

More information

1420 Miner Street Des Plaines, IL P: desplaines.org COMMERCIAL STRUCTURES (INCLUDING ALTERATIONS AND ADDITIONS)

1420 Miner Street Des Plaines, IL P: desplaines.org COMMERCIAL STRUCTURES (INCLUDING ALTERATIONS AND ADDITIONS) 1420 Miner Street Des Plaines, IL 60016 P: 847.391.5380 desplaines.org COMMERCIAL STRUCTURES (INCLUDING ALTERATIONS AND ADDITIONS) Five sets of stamped plans and specifications (six sets if food establishment),

More information

City of Surrey PLANNING & DEVELOPMENT REPORT File:

City of Surrey PLANNING & DEVELOPMENT REPORT File: City of Surrey PLANNING & DEVELOPMENT REPORT PROPOSAL: Planning Report Date: September 13, 2010 Development Permit in order to permit the expansion of the Fraser Heights Recreation Centre. LOCATION: OWNER:

More information

Christy Usher, AICP Associate Planner Phone Fax:

Christy Usher, AICP Associate Planner Phone Fax: Item No: 2 Meeting Date: March 12, 2013 To: Planning Commission Date: March 7, 2013 Authorized By: Ron Munekawa Chief of Planning By: Christy Usher, AICP Associate Planner Phone 650 522-7215 Fax: 522-7201

More information