1 NHBC s technical newsletter August 2002 Issue 24 This edition includes: New Contaminated Land Guideline Values The introduction of Soil Guideline Values. Approved Document H (Drainage and waste disposal) A summary of key changes. Reports on the condition of flues and appliances at completion Greater emphasis on testing. European Standards and CE Marking What are they and what do you need to do? EXTRA STANDARDS EXTRA 1

2 CONTENTS 2 New Contaminated Land Guideline Values 3 Approved Document H 4 And still on drainage 4 Clarification - Approved Document L and Robust Details 4 Reports on the condition of flues and appliances at completion 5 European Standards and CE Marking New Contaminated Land Guideline Values The contaminated land exposure assessment (CLEA) model, and four supporting contaminated land reports (CLR 7-10), were published by the Department for Environment, Food and Rural Affairs (DEFRA) and the Environment Agency in March this year. These provide a scientifically based framework for the assessment of risks to human health from land contamination. When dealing with potentially contaminated sites, the most important question is: does the concentration of contaminant X pose a significant risk to human health or the environment? The CLEA model and new soil guideline values (SGVs) will help to answer this question with respect to human health. SGVs represent 'intervention values' which indicate to an assessor that soil concentrations above this level could pose an unacceptable risk to the health of site users and that further investigation or remediation is required. The primary purpose of SGVs is to determine if the existing land use poses unacceptable risks to human health under Part IIA of the Environmental Protection Act This legislation requires local authorities to identify land, in its present use, within their areas, which they consider to be contaminated. However, the SGVs will also be used in the context of development control to inform judgement for safe development. SGVs for 7 contaminants have been published so far, with values for each of three typical land uses: residential, allotments and industrial/commercial. Values for a total of more than 50 contaminants are expected eventually, although this may take several years. As they are published, the SGVs will replace the ICRCL (The Department of the Environment Interdepartmental Committee on the Redevelopment of Contaminated Land 1987) values that were published for 17 contaminants encountered on many sites. In addition the reports contain toxicological data which set out the Tolerable Daily Intakes and Index Doses for contaminants to support the derivation of the SGVs. These publications are available from: Environment Agency R & D Dissemination Centre c/o WRc, Frankland Road, Swindon, Wilts SN5 8YF Tel: publications@wrcplc.co.uk or can be downloaded from the DEFRA web site at ACTION: NHBC will expect consultants to make use of the new values, as they are published, in association with the guidance contained in NHBC Standards Chapter 4.1 and the NHBC/EA document entitled Guidance for the Safe Development of Housing on Land Affected by Contamination. 2 STANDARDS EXTRA

3 Approved Document H (Drainage and waste disposal) This article summarises the key changes in the 2002 edition of Approved Document H (England & Wales). Drainage layouts The guidance in Part H may significantly affect the layouts of drains on your developments. The requirement for 150mm diameter drains where serving more than 10 properties is well known but the Building Regulations now require drains serving more than one property to be kept clear from areas where future extensions are likely. In addition, access points should be located in places where they are accessible and apparent for maintenance in an emergency. This could be highways, public open space, unfenced front gardens and shared or unfenced driveways but not rear gardens! This change could have a significant effect on the designs of drainage schemes for your future developments. The recently published DEFRA document Protocol on Design, Construction and Adoption of Sewers in England and Wales confirms that there is a need for developers and the sewerage undertaker to work in close liaison. The intention of the protocol is to prevent the proliferation of private sewers and consequent problems of maintenance and ownership associated with them. This can be achieved by harmonising the essential elements of design and construction of sewers contained in Approved Document H with the guidance in the 5th edition of Sewers for adoption. So the message here is consult with the sewerage undertaker in accordance with the protocol prior to working up drainage schemes for approval by the building control body. It would be prudent to review your schemes now to ensure compliance with Approved Document H and the DEFRA Protocol. Surcharging of drains Many incidents of sewer flooding are due to surcharge into basements. For low lying sites (where the ground level of the site or the level of the basement is below the level of the ground at the point where the drainage connects to the existing sewer) care should be taken to ensure that dwellings are not an increased risk due to flooding. The Building Regulations now address this issue by requiring anti-flood measures such as the provision of pumped drainage or anti-flood valves depending on the risk of surcharge. So how do house builders determine the risk of surcharge? The answer is to consult the sewerage undertaker. You need to consult the sewerage undertaker whenever you intend to develop a site that is low lying or the proposal incorporates a basement. The sewerage undertaker can advise on the risk of surcharge, which will help you to determine what measures are necessary to prevent flooding. Building over sewers The requirements for building over sewers have now been incorporated into the Building Regulations. It is important that you check the sewer maps held by the sewerage undertaker to determine the location of sewers on site. Make sure you advise the building control body whenever you intend to build (or underpin) over or near to (within 3m of the centre line) a drain, sewer or disposal main shown on the map of sewers. You should also consult the owner of that sewer or drain (normally the sewerage undertaker). Building control bodies will take the requirements of the sewerage undertaker into account prior to granting approval for the works. Again consultation is the key to avoiding costly unexpected changes to designs during the development programme. Rodent control With increasing development of brownfield sites so our attention has been turned by Building Regulations to the problems of rat infestation. So how do you know if a site is at risk and requires additional protection such as rodent barriers or intercepting traps? Ask the environmental health department of the local authority whether any special measures are required for the control of rodents. Let the building control body know the result of the consultation so they can take this into account when assessing drainage designs for compliance. Solid waste storage Although Building Regulations offer detailed guidance on refuse storage and siting, more emphasis is now given on the need to consult the waste collection authority to determine their requirements. The waste collection authority has powers to specify the number and type of receptacles to be used and the location where the waste should be placed for collection. So make sure you consult the waste collection authority prior to finalising your designs for approval by the building control authority. ACTION: The 2002 edition of Approved Document H of the Building Regulations introduces some new challenges. House builders should consult with the relevant statutory authorities to minimise the effect of these on your future developments. STANDARDS EXTRA 3

4 and still on drainage here is a problem which occurred because of the movement of shrinkable clay Highly plastic clays are able to swell or shrink by up to 150mm. It is therefore important to ensure that all elements of the house construction that may be subject to movement (including the drains and other services) are able to accommodate it without adverse effect. This picture, taken from underneath a house in Essex, shows the foul drain passing through the outside wall over the top of the ground beam. The rising ground has caused the foul drain to lift and crush against the mortar droppings that have fallen down the cavity. The combination of the backfall and the constricted bore has stopped the drain from working. The cost of rectifying the drainage problem alone on 12 properties on the development was in excess of 400,000. Points to consider: Is the cavity free of mortar droppings at the base of the wall? Is the fall of the drainage system sufficient to cater for likely differential movement in the pipe run? Is there room for pipework to move uniformly if it is likely to be subjected to heave or shrinkage? Does the construction allow for differential movement where it may occur? Clarification Approved Document L and Robust Details Standards Extra 23 (page 3) In Standards Extra 23 (page 3) we advised of changes to the NHBC Standards made to align them with the 2002 edition of Approved Document L "Conservation of fuel and power" (England and Wales) and the Robust Details document. The article stated that the Standards changes would be effective for all homes from 1 October This was incorrect. NHBC would like to clarify that the changes to the Standards to align with the 2002 edition of Approved Document L and Robust Details apply only in England and Wales to homes where required by the Building Control Approval. Reports on the condition of flues and appliances at completion The Government has asked building control bodies to obtain a report detailing the condition of flues and appliances at completion stage for each installation. All flues now need to be tested to ensure their integrity and, where an appliance has been installed, a spillage test needs to be carried out to confirm the safe operation of flue and appliance. Builders are responsible for ensuring these tests have been carried out and that a report is available for review by the building control body. Now is the time to give consideration to how you will comply. Speak to your specialist contractors and make sure they know what is expected. Consider where these reports will be held so that they can be easily retrieved when requested by the building control body. Remember that if a report is not available a Final Certificate cannot be authorised. ACTION: Builders should familiarise themselves with the changes to Part J and make sure that reports are available on site. STANDARDS EXTRA 4

5 European Standards and CE Marking What are European Standards? European Standards for products are now starting to take over from the British Standards we are all familiar and comfortable with. For instance, NHBC has already recognised the relevant European Standard for chipboard flooring. The reference to BS 5669 was changed some time ago to BS EN 312 and this is how the material should be ordered, including the new grade Type P5. As time goes on, more and more European Standards will replace British Standards and manufacturers, both in the UK and across the Channel, will be making their products to the new standards. What is CE Marking and what does it tell me? CE marking(see below) indicates that the product meets the minimum requirements to allow it to enter the European market. The technical requirements are set out in European standards and the information accompanying the CE marking provides the user with some basic technical details of the product. This information will be useful to building control bodies for building regulation purposes. Although the products have to satisfy type testing and factory production control requirements, these tasks do not always have to be done by a third party, so the CE marking should not be regarded as a quality mark. Do I have to use CE marked products? Products which have CE marking can be freely traded across Europe under European law. To do this, it has been necessary for all European countries to agree the content of each standard and this has led to many delays in their preparation. Over such a large geographical area, what is not critical to Mediterranean countries can be critical to countries like the UK further north. For example, roof tiles which may be suitable for frost free climates won t be suitable to withstand our winters. It is not necessary to use CE marked products. However, by using CE marked products of the correct grade or class it will help to satisfy the building control body because they are generally obliged to accept information accompanying the mark as being correct. It s worth mentioning that under the European rules only certain products can be CE marked Why do I have to change to the new system? Many manufacturers are international companies and will want to sell their products in the UK, Europe and possibly worldwide. It is inevitable that to sell products to the widest market, manufacturers will switch to the new European Standards. In fact, British Standards as we know them, won t exist. As part of European law, the UK will have to withdraw its national standard once a European Standard is published, subject to a transitional period where both will run in parallel. What do I need to do now? Keep yourself abreast of changes to Standards. Government agencies, BSI and manufacturers will all be providing information on the new regime. For those products which are critical for Building Regulation purposes check with manufacturers on whether they have changed to new European Standards. Check that any material or product has characteristics, which are equal to or better than the current Standard. This is not always as easy as it sounds because European Standards are written in performance terms whereas British Standards have generally been prescriptive. Although this concept is a different approach to standards making, it won t mean that products will change significantly from those we use today. Where can I obtain more information? The following websites have information on CE marking; The Office of the Deputy Prime Minister ( British Standards Institution ( Example of what the CE mark may tell you. 5 STANDARDS EXTRA

6 s & s Below are the answers to a selection of questions we have recently been asked in NHBC Technical. Drainage connections to pre-formed inspection chamber bases Where pre-formed inspection chamber bases are used, does the main channel entry connection have to be used in all instances or can connections be made using the branch connections? The entry connections should ensure no deposits can accumulate within the base where they can then lodge and cause blockages. To avoid a build up of solids the main channel entry connection should be used in all cases. Where two drains meet a base from different directions, the inspection chamber should be turned and swept bends used to connect one drain to the main channel. The other drain can be connected to a side entry as shown. Diagonal bracing to double hipped roof Is diagonal bracing needed on a double hipped roof? Hipped ends will tend to provide stability, and according to BS , Code of practice for trussed rafter roofs, hipped roofs do not require diagonal bracing if the length of the roof between the hip ends is less than 1.8m. Partial fill insulation to gable walls Where partial fill insulation is placed in the cavity but does not continue to the top of the gable wall, is a cavity tray needed? Installing a cavity tray with weepholes above is good practice. The cavity tray should not significantly weaken the gable. However, provided workmanship is acceptable and insulaton is adequately retained against the inner leaf so that there is a nominal 50mm clear cavity between the insulation and the outer leaf, a cavity tray is not needed. Insulation of extract ducting Should the duct from an extract fan running in the roof void be insulated to prevent condensation running back into the fan? Condensation could cause damage to the extract fan and condensation dripping from the fan could be a nuisance to the home owner. Therefore the duct should be insulated (placed under the roof insulation where practical). Alternatively, a condensation trap should be provided with pipework to the outside, laid to a fall. 6 NHBC Technical Buildmark House, Chiltern Avenue, Amersham, Bucks HP6 5AP Tel: Fax: technical@nhbc.co.uk HB /02

Concrete specifications and BRE Special Digest 1 We detail the main changes that you need to take account of

Concrete specifications and BRE Special Digest 1 We detail the main changes that you need to take account of NHBC s technical newsletter September 2005 Issue 33 This edition includes: 2 Concrete specifications and BRE Special Digest 1 We detail the main changes that you need to take account of 3 4 5 Robust Details

More information

Part 5 Substructure and ground floors. Chapter 5.2. Suspended ground floors

Part 5 Substructure and ground floors. Chapter 5.2. Suspended ground floors Part 5 Substructure and ground floors Chapter CONTENTS SCOPE Clause Page DESIGN - General Design standards D1 1 Statutory and other requirements D2 1 Resistance to ground contaminants D3-D4 1 This Chapter

More information

Building over or close to a public sewer

Building over or close to a public sewer Building over or close to a public sewer Place holder image thameswater.co.uk/developerservices Building over or close to a public sewer Did you know Thames Water is legally responsible for more than 100,000

More information

New connection to a public sewer

New connection to a public sewer New connection to a public sewer Application form You can go to our website thameswater.co.uk/buildover and apply online or complete this form and return to Thames Water, Developer Services, Clearwater

More information

Resistance to the passage of sound

Resistance to the passage of sound The Building Regulations 2000 The Building (Approved Inspectors etc) Regulations 2000 E APPROVED DOCUMENT E1 Protection against sound from other parts of the building and E2 E3 E4 adjoining buildings Protection

More information

Resistance to the passage of sound

Resistance to the passage of sound The Building Regulations 2000 The Building (Approved Inspectors etc) Regulations 2000 E APPROVED DOCUMENT E1 Protection against sound from other parts of the building and E2 E3 E4 adjoining buildings Protection

More information

Application Pack 5. How to apply for a Connection to a Public Sewer/Lateral Drain

Application Pack 5. How to apply for a Connection to a Public Sewer/Lateral Drain Application Pack 5 How to apply for a Connection to a Public Sewer/Lateral Drain Guidance Notes The provisions of the Water Industry Act 1991 (WIA91) take precedence over these notes. We recommend that

More information

ACO Building Drainage

ACO Building Drainage ACO Building Drainage Backflow systems Installation, Operation and Maintenance Manual ACO TRIPLEX Anti-flood valve for GREYWATER drainage (wastewater without sewage) PLEASE READ THESE INSTRUCTIONS BEFORE

More information

Environment Agency Guidance on Requirements for Land Contamination Reports. July 2005

Environment Agency Guidance on Requirements for Land Contamination Reports. July 2005 Environment Agency Guidance on Requirements for Land Contamination Reports July 2005 ENVIRONMENT AGENCY GUIDANCE ON REQUIREMENTS FOR LAND CONTAMINATION REPORTS Context Who is this guidance aimed at? Developers,

More information

HP Partial Fill. Robust, long-lasting protection

HP Partial Fill. Robust, long-lasting protection 1 CONSTRUCTION TYPE: cavity walls HP Partial Fill Cavity Walls Robust, long-lasting protection HP Partial Fill slabs have a robust outer surface, designed to withstand on-site rigours and maintain a clearly

More information

Affinity Water Limited New Supplies

Affinity Water Limited New Supplies 1 of 13 Affinity Water Limited New Supplies Policy and Company Specific Requirements for Water Mains and Service Pipes Constructed by Self-Lay Organisations 2 of 13 CONTENTS 1 Introduction 3 1.1 General

More information

Robust Details Part E NHBC looks at the new Robust Details scheme, providing an alternative way of complying with new Part E Regulations

Robust Details Part E NHBC looks at the new Robust Details scheme, providing an alternative way of complying with new Part E Regulations NHBC s technical newsletter August 2004 Issue 30 This edition includes: 2 Balustradings - What is easily climbable? We look at a test on climbability of various balustrading designs 3 4 7 7 Breathable

More information

You are also similarly responsible for any part crossing any neighbouring land, including any length of private service pipe in the public highway.

You are also similarly responsible for any part crossing any neighbouring land, including any length of private service pipe in the public highway. Shared supply or lead water pipe replacement connections guidance notes Up to 25mm diameter supplies Introduction Our aim is to deliver an excellent standard of service. In order for us to do this and

More information

OSMADRAIN UNDERGROUND DRAINAGE SYSTEM OSMADRAIN UNIVERSAL GULLY SYSTEM

OSMADRAIN UNDERGROUND DRAINAGE SYSTEM OSMADRAIN UNIVERSAL GULLY SYSTEM Wavin UK (Holdings) Ltd Parsonage Way Chippenham Wiltshire SN15 5PN Tel: 01249 654121 Fax: 01249 443286 e-mail: info@wavin.co.uk website: www.wavin.co.uk APPROVAL INSPECTION TESTING CERTIFICATION TECHNICAL

More information

Technical Guidance Note

Technical Guidance Note Technical Guidance Note THE BUILDING REGULATIONS 2004 EDITION ENGLAND AND WALES REQUIREMENT A3 DISPROPORTIONATE COLLAPSE 1. INTRODUCTION (a) This technical guidance note outlines NHBC s interpretation

More information

ENGINEERING STANDARD FOR DRAIN AND SEWER SYSTEMS OUTSIDE BUILDINGS FIRST EDITION NOVEMBER 2013

ENGINEERING STANDARD FOR DRAIN AND SEWER SYSTEMS OUTSIDE BUILDINGS FIRST EDITION NOVEMBER 2013 ENGINEERING STANDARD FOR DRAIN AND SEWER SYSTEMS OUTSIDE BUILDINGS FIRST EDITION NOVEMBER 2013 This Standard is the property of Iranian Ministry of Petroleum. All rights are reserved to the owner. Neither

More information

Energy Performance Certificate

Energy Performance Certificate Energy Performance Certificate 22, Birchdale Road Appleton WARRINGTON WA4 5AR Dwelling type: Semi-detached bungalow Date of assessment: 13 August 2009 Date of certificate: 13 August 2009 Reference Number:

More information

Self lay policy. Company specific addendum to Code of Practice for the self laying of Water Mains and Services England and Wales 2 nd Edition May 2009

Self lay policy. Company specific addendum to Code of Practice for the self laying of Water Mains and Services England and Wales 2 nd Edition May 2009 Self lay policy and Company specific addendum to Code of Practice for the self laying of Water Mains and Services England and Wales 2 nd Edition May 2009 Issue 2 - May 2013 Contents Introduction Page 3

More information

Company specific addendum

Company specific addendum Self lay policy and Company specific addendum to Code of Practice for the self laying of Water Mains and Services England and Wales 2 nd Edition May 2009 Issue 1.0 - April 2015 life fl ow smoothly helping

More information

Aldersgrove Avenue 1 London, SE9. Let 1,200 per month + fees

Aldersgrove Avenue 1 London, SE9. Let 1,200 per month + fees Aldersgrove Avenue 1 London, SE9 Let 1,200 per month + fees La Casa is pleased to present this spacious, end of terrace two bedroom house. This newly decorated house is light, airy and well proportioned

More information

Storm Water Management

Storm Water Management Storm Water Management Policy September 2014 2 Sustainable drainage feature designed to control and manage flows through a series of check dams 3 Document Name: Storm Water Management Controlled Copy No:

More information

Developer Services. Building over or near a sewer. DEV 005G Guidance notes and procedure. What is a public sewer?

Developer Services. Building over or near a sewer. DEV 005G Guidance notes and procedure. What is a public sewer? Developer Services DEV 005G Guidance notes and procedure Building over or near a sewer If you are thinking of building a structure (for example, a new building, extension, conservatory, garage etc.) you

More information

Energy Performance Certificate

Energy Performance Certificate 6 Desmond Road WATFORD WD24 5LH Dwelling type: Date of assessment: Date of certificate: Reference number: Total floor area: Mid-terrace house 27 June 2008 27 June 2008 8809-9734-4820-6926-2683 63 m² This

More information

Building over or near a public sewer.

Building over or near a public sewer. Building over or near a public sewer. www.developers.thameswater.co.uk 0800 009 39 Monday to Friday, 8am to 5pm If you re planning a new building, a conservatory, a garage or any other extension to your

More information

Energy Performance Certificate

Energy Performance Certificate Energy Performance Certificate 14, Primula Drive, NORWICH, NR4 7LZ Dwelling type: Detached house Date of assessment: 11 January 2009 Date of certificate: Reference number: 11 January 2009 Total floor area:

More information

Energy Performance Certificate

Energy Performance Certificate Energy Performance Certificate 29, Cranleigh Mead, Dwelling type: Semi-detached house CRANLEIGH, GU6 7JS Date of assessment: 24 July 2008 Date of certificate: Reference number: 24 July 2008 8288-6423-4530-2904-6026

More information

Approved Document to support regulation

Approved Document to support regulation The Building Regulations 2010 Approved Document to support regulation Materials and Workmanship 2013 edition - for use in Wales* Main changes in the 2013 edition This approved document supports regulation

More information

Energy use 690 kwh/m² per year 425 kwh/m² per year. Carbon dioxide emissions 7.9 tonnes per year 4.9 tonnes per year. Lighting 53 per year 30 per year

Energy use 690 kwh/m² per year 425 kwh/m² per year. Carbon dioxide emissions 7.9 tonnes per year 4.9 tonnes per year. Lighting 53 per year 30 per year Energy Performance Certificate 70, Gorton Street BLACKPOOL FY1 3HP Dwelling type: Mid-terrace house Date of assessment: 21 September 2007 Date of certificate: 21 September 2007 Reference number: 2498-3098-6231-4823-7094

More information

DEMOLITION TRADE SPECIFICATION

DEMOLITION TRADE SPECIFICATION DEMOLITION TRADE SPECIFICATION GENERAL a) BDW Trading Limited Barratt Homes and David Wilson Homes are all trading names of BDW Trading Limited the Company. b) Site Condition The Contractor is to examine

More information

Energy Performance Certificate

Energy Performance Certificate Energy Performance Certificate 6, Heron Road Kelvedon COLCHESTER CO5 9NE Dwelling type: Detached house Date of assessment: 15 September 2008 Date of certificate: 16 September 2008 Reference number: 8908-6621-5680-4085-5096

More information

Regulation: 10 Fitness of materials Standard: B2.1 Selection and use of materials and components Comment:

Regulation: 10 Fitness of materials Standard: B2.1 Selection and use of materials and components Comment: 1st Insulation Partners Limited Insulation House Shaw Road Rotherham Yorks S65 1SN Tel: 01709 365785 Fax: 01709 365786 e-mail: firstinsulation@lineone.net CI/SfB (21.1) Ym1 (M2) Agrément Certificate No

More information

Energy Performance Certificate

Energy Performance Certificate Energy Performance Certificate 46, Sea Road Chapel St. Leonards SKEGNESS PE24 5SA Dwelling type: Detached bungalow Date of assessment: 18 July 2008 Date of certificate: 21 July 2008 Reference number: 9488-9039-6253-4398-3024

More information

Energy Performance Certificate

Energy Performance Certificate Energy Performance Certificate 129, North Road St. Andrews BRISTOL BS6 5AH Dwelling type: Mid-terrace house Date of assessment: 7 January 2009 Date of certificate: 7 January 2009 Reference number: 8281-6129-5770-1683-9006

More information

Below Ground Drain and Sewer Solutions

Below Ground Drain and Sewer Solutions BGDSS MAY 2016 Below Ground Drain and Sewer Solutions Solutions for adoptable and non-adoptable drains and sewers 1 Welcome to Polypipe At Polypipe, conceiving, designing, manufacturing and delivering

More information

PAGE 415. Part 9. External works. 9.1 Garages. 9.2 Drives, paths and landscaping

PAGE 415. Part 9. External works. 9.1 Garages. 9.2 Drives, paths and landscaping PAGE 415 Part 9 External works 9.2 Drives, paths and landscaping Part 9 External works Chapter CONTENTS SCOPE Clause DESIGN Design standards D1 1 Statutory requirements D2 1 Garage foundations D3 1 Garage

More information

Expired Report. Energy Performance Certificate. England & Wales. ) Rating. Environmental Impact (CO ². Energy Efficiency Rating

Expired Report. Energy Performance Certificate. England & Wales. ) Rating. Environmental Impact (CO ². Energy Efficiency Rating Energy Performance Certificate 2, Forest Patch Berry Hill COLEFORD GL16 8RB Dwelling type: Detached bungalow Date of assessment: 1 October 2008 Date of certificate: 3 October 2008 Reference number: 8498-6520-5349-6179-7002

More information

Extra 35. Standards. NHBC s technical newsletter. May This edition includes: Introducing Chapter a consistent approach to finishes

Extra 35. Standards. NHBC s technical newsletter. May This edition includes: Introducing Chapter a consistent approach to finishes NHBC s technical newsletter Standards Extra 35 May 2006 This edition includes: Introducing Chapter 1.2 - a consistent approach to finishes Revised Building Regulations Parts L & F Internal services get

More information

Energy Performance Certificate

Energy Performance Certificate Energy Performance Certificate 6, Chynoweth Gardens, Gulval PENZANCE TR18 3DL Dwelling Type: Semi-detached bungalow Date of Assessment: 05/03/008 Date of Certificate: 05/03/008 Reference Number: 8618-647-4330-4585-500

More information

Energy Performance Certificate

Energy Performance Certificate Energy Performance Certificate 60, Haycroft Drive Matson, GLOUCESTER GL4 6XX Dwelling Type: Detached house Date of Assessment: 25/09/2007 Date of Certificate: 02/10/2007 Reference Number: 83136721487032152022

More information

Energy Performance Certificate

Energy Performance Certificate Energy Performance Certificate 138, South Crockerford, BASILDON, SS16 4JB Dwelling type: Midterrace house Date of assessment: Date of certificate: Reference number: 84816221603027311006 Total floor area:

More information

Energy Performance Certificate

Energy Performance Certificate Energy Performance Certificate 24, King Street, Dwelling type: Mid-terrace house NORMANTON, WF6 1EW Date of assessment: 07 April 2008 Date of certificate: Reference number: 07 April 2008 8802-5334-1620-6006-7483

More information

building the future AF32 AVE100/AV110 AF110 FloPlast Limited Castle Road Eurolink Business Park Sittingbourne Kent ME10 3FP UK

building the future AF32 AVE100/AV110 AF110 FloPlast Limited Castle Road Eurolink Business Park Sittingbourne Kent ME10 3FP UK FloPlast Limited Castle Road Eurolink Business Park Sittingbourne Kent ME10 3FP UK Tel: +44 (0)1795 431731 Fax: +44 (0)1795 431188 Sales Office Direct Line: +44 (0)1795 421422 Email: sales@floplast.co.uk

More information

Approved Document. Drainage and waste disposal. The Building Regulations 2010

Approved Document. Drainage and waste disposal. The Building Regulations 2010 The Building Regulations 2010 Approved Document H1 Foul water drainage H2 Wastewater treatment systems and cesspools H3 Rainwater drainage H4 Building over sewers H5 Separate systems of drainage H6 Solid

More information

Floors Walls Roofs. Jabfill Premium. APPLICATION: Full-fill Cavity Wall Insulation PRODUCTS: Vencel Resil Limited

Floors Walls Roofs. Jabfill Premium. APPLICATION: Full-fill Cavity Wall Insulation PRODUCTS: Vencel Resil Limited Floors Walls Roofs APPLICATION: Full-fill Cavity PRODUCTS: Vencel Resil Limited Head Office: Infinity House, Anderson Way, Belvedere, Kent DA17 6BG Tel: 020 8320 9100 Fax: 020 8320 9110 Technical Services:

More information

Memorandum of Understanding

Memorandum of Understanding Memorandum of Understanding between the NSW Ministry of Health and Sydney Water Corporation July 2016 MoU between Sydney Water and NSW Ministry of Health - July 2016 Page 1 of 11 1. Introduction and purpose

More information

Via to:

Via  to: Via email to: FloodsandWaterBill@defra.gsi.gov.uk Simon Hewitt Flood and Water Management Bill Team Department for Environment, Food and Rural Affairs Area 2C Ergon House London SW1P 2AL Dear Sir, Draft

More information

Energy Performance Certificate

Energy Performance Certificate Energy Performance Certificate 56 Malvern Road CAMBRIDGE CB1 9LD Dwelling type: Date of assessment: Date of certificate: Reference number: Total floor area: Mid-terrace house 09 October 2008 10 October

More information

Sewerage connections guidance notes

Sewerage connections guidance notes Sewerage connections guidance notes Sections 106 to 109 Water Industry Act 1991 Please read these guidance notes carefully before completing the attached application form. Introduction This guide has been

More information

WASTEWATER DRAINAGE BYLAW

WASTEWATER DRAINAGE BYLAW WASTEWATER DRAINAGE BYLAW 2018 Pursuant to Section 145 of the Local Government Act 2002 and every other enabling power and authority. To come into force: 1 July 2018 For the purpose of: a) Controlling

More information

This policy will generally explain the following in regards to the City sewerage collection systems:

This policy will generally explain the following in regards to the City sewerage collection systems: CITY OF SACO POLICY ON SEWER AND STORMWATER BACK-UPS PURPOSE The purpose of this policy is to explain how and why sewer or stromwater backups occur, what to do in the event a homeowner has a backup, and

More information

LABSS INFORMATION PAPER INFOP Version 2

LABSS INFORMATION PAPER INFOP Version 2 LABSS INFORMATION PAPER INFOP05-2018 Version 2 ALTERATIONS TO EXISTING DWELLINGS External Wall Insulation System Applicable to Domestic Buildings only in relation to Administration and Supporting Information

More information

Energy Performance Certificate

Energy Performance Certificate Energy Performance Certificate 33, Wingfield Road NORWICH NR3 3HF Dwelling type: Date of assessment: Date of certificate: Reference number: Total floor area: Mid-terrace house 21 May 2009 21 May 2009 2998-4025-6205-6421-2074

More information

Energy Performance Certificate

Energy Performance Certificate Energy Performance Certificate 2, Sandpiper Close ROCHDALE OL11 5QD Dwelling type: Detached house Date of assessment: 1 July 2009 Date of certificate: 2 July 2009 Reference number: 8701-6223-6070-2459-7006

More information

Drainage and waste disposal

Drainage and waste disposal The Building Regulations 2000 H APPROVED DOCUMENT H1 H2 H3 H4 H5 H6 Foul water drainage Wastewater treatment systems and cesspools Rainwater drainage Building over sewers Separate systems of drainage Solid

More information

9 Revision B

9 Revision B JJI-JOIST TECHNICAL BULLETIN SUBJECT: Ground Floor Design & Restraint Bulletin Number: Date Issued: Sheet 1 of 11 Introduction When designing the ground floor of a residential dwelling using I-Joists,

More information

Figure 1 Part site plan showing location of house and drive (drainage not shown)

Figure 1 Part site plan showing location of house and drive (drainage not shown) Determination 2008/101 The compliance of a foul water drain at 25 Marlowe Place, Rolleston Figure 1 Part site plan showing location of house and drive (drainage not shown) 1. The matter to be determined

More information

Applying for a sewer connection Guidance Notes

Applying for a sewer connection Guidance Notes Applying for a sewer connection Guidance Notes Introduction Under Section 106 of the Water Industry Act 1991, the owner of any domestic property is entitled to have foul and surface water from their property

More information

NEWS LETTER. May 9, 2011

NEWS LETTER. May 9, 2011 PLANNING, BUILDING & DEVELOPMENT SERVICES DEPARTMENT 580-1 Street S.E. Medicine Hat, Alberta T1A 8E6 Telephone: 529-8374 FAX 502-8038 NEWS LETTER May 9, 2011 GENERAL As per requests from the construction

More information

MUNSTER SIMMS DRAINAGE SYSTEMS WHALE SMOOTHFLOW AND DRY-DECK PUMPED SHOWER DRAINAGE SYSTEMS

MUNSTER SIMMS DRAINAGE SYSTEMS WHALE SMOOTHFLOW AND DRY-DECK PUMPED SHOWER DRAINAGE SYSTEMS Munster Simms Engineering Ltd (t/a Whale Water Systems) Old Belfast Road Bangor Co Down BT19 1LT Tel: 028 9127 0531 Fax: 028 9146 6421 e-mail: info@whalepumps.com website: www.whalepumps.com APPROVAL INSPECTION

More information

Dwelling Type: Mid-terrace house

Dwelling Type: Mid-terrace house Energy Performance Certificate 7, William Way DEREHAM NR19 1TQ Dwelling Type: Mid-terrace house Date of Assessment: 06/06/008 Date of Certificate: 06/06/008 Reference Number: 848-66-400-1896-1006 Total

More information

Energy Performance Certificate

Energy Performance Certificate Energy Performance Certificate The Old Post Office Dwelling type: Detached house Sarson Lane Date of assessment: 01 July 2009 Amport Date of certificate: 01 July 2009 ANDOVER Reference number: 0298-3065-6253-6141-2070

More information

Energy Performance Certificate

Energy Performance Certificate Energy Performance Certificate 387a, Stockport Road, Dwelling type: Top-floor flat Timperley, Date of assessment: 29 July 2008 ALTRINCHAM, WA15 7UR Date of certificate: 29 July 2008 Reference number: 0645-2891-6630-0628-6061

More information

Energy Performance Certificate

Energy Performance Certificate Energy Performance Certificate 563, Warrington Road, Abram WIGAN WN2 5XY Dwelling type: Mid-terrace house Date of assessment: 03 November 2008 Date of certificate: 03 November 2008 Reference number: 0378-4979-6289-5238-6064

More information

Polysewer Gravity Sewer System SPECIFICATION

Polysewer Gravity Sewer System SPECIFICATION Polysewer Gravity Sewer System SPECIFICATION July 2014 SCOPE OF WORKS To meet the specific performance criteria detailed within this specification and accompanying drawings. The completed drainage systems

More information

1. The matter to be determined

1. The matter to be determined Determination 2017/051 Regarding the refusal to issue a code compliance certificate for a 10-year-old house with brick veneer cladding at 15 Devine Drive, Claremont Estate, Rolleston Summary This determination

More information

Physical infrastructure for high-speed electronic communications networks

Physical infrastructure for high-speed electronic communications networks The Building Regulations 2010 Physical infrastructure for high-speed electronic communications networks APPROVED DOCUMENT R R1 In-building physical infrastructure 2016 edition for use in England* 2016

More information

Energy Performance Certificate

Energy Performance Certificate Energy Performance Certificate Flat 7, Dwelling type: Mid-floor flat 19, Davenport Road, Date of assessment: 18 July 2008 COVENTRY, CV5 6QH Date of certificate: 18 July 2008 Reference number: 0446-2898-6735-0398-5321

More information

Energy Performance Certificate

Energy Performance Certificate Energy Performance Certificate 10, Roman Walk, Stoke Gifford BRISTOL BS34 8UH Dwelling type: Detached house Date of assessment: 07 August 2009 Date of certificate: 07 August 2009 Reference number: 0138-3042-6258-6551-8004

More information

FERNCO PIPE CONNECTORS AND COUPLINGS FERNCO FLEXIBLE COUPLINGS

FERNCO PIPE CONNECTORS AND COUPLINGS FERNCO FLEXIBLE COUPLINGS Flex-Seal Couplings Ltd Endeavour Works Newlands Way Valley Park Wombwell Barnsley Yorkshire S73 0UW Tel: 01226 340222 Fax: 01226 340400 e-mail: sales@flexseal.co.uk website: www.flexseal.co.uk www APPROVAL

More information

Section 106 New connection to a public sewer: Guidance notes

Section 106 New connection to a public sewer: Guidance notes Section 106 New connection to a public sewer: Guidance notes Page 1 15 May 2012 Sewer Connection Guidance Notes Section 106 and 107 of the Water Industry Act 1991 IT IS A CRIMINAL OFFENCE TO MAKE A CONNECTION

More information

Requirements for Manufacturing, Transporting, Siting, Commissioning and preparation of Park Home Bases

Requirements for Manufacturing, Transporting, Siting, Commissioning and preparation of Park Home Bases Gold Shield Code of Practice Requirements for Manufacturing, Transporting, Siting, Commissioning and preparation of Park Home Bases 1 Manufacturing Requirements 1.1 Manufacturers are responsible for providing

More information

Energy Performance Certificate

Energy Performance Certificate Energy Performance Certificate 10, Depleach Road, CHEADLE, SK8 1DZ Dwelling type: Detached house Date of assessment: 15 April 2009 Date of certificate: Reference number: 15 April 2009 84716624691000351092

More information

Pollution Control. A Range of Package Pump Systems for Residential & Commercial Developments. klargester.com

Pollution Control. A Range of Package Pump Systems for Residential & Commercial Developments. klargester.com Pollution Control All All New New 2006 2006 Pump Pump Range Range from from Klargester Klargester with with 24hr 24hr Storage Storage A Range of Package Pump Systems for Residential & Commercial Developments

More information

Energy Performance Certificate

Energy Performance Certificate Energy Performance Certificate 10, Levett Avenue, Dwelling type: Semi-detached house POLEGATE, BN26 6LW Date of assessment: 23 March 2008 Date of certificate: Reference number: 25 March 2008 2078-1079-6217-4558-8040

More information

Loss Prevention Standard

Loss Prevention Standard Loss Prevention Standard LPS 1208: Issue 2.2 This Loss Prevention Standard is the property of BRE Global Ltd. and is made publicly available for information purposes only. Its use for testing, assessment,

More information

Proposed Alterations and Extension to 17 St. John's Road, Sandymount, Dublin 4

Proposed Alterations and Extension to 17 St. John's Road, Sandymount, Dublin 4 Proposed Alterations and Extension to 17 St. John's Road, Sandymount, Dublin 4 Engineering Report April, 2014 1422 Issue 1 Casey O Rourke Associates Structural & Civil Consulting Engineers 77 Merrion Square

More information

Energy Performance Certificate

Energy Performance Certificate Energy Performance Certificate 25 Lockhart Road Ellingham BUNGAY Suffolk NR35 2HB Dwelling type: Date of assessment: Date of certificate: Reference number: Total floor area: Detached bungalow 06 April

More information

Energy Performance Certificate

Energy Performance Certificate Energy Performance Certificate 118, Teign Bank Road, Dwelling type: End-terrace house HINCKLEY, LE10 0EE Date of assessment: 23 April 2008 Date of certificate: Reference number: 23 April 2008 0449-2867-6643-0928-7045

More information

Two complete sets of plans that are legible and drawn to conventional scale are required to be submitted with the Building Permit Application Form.

Two complete sets of plans that are legible and drawn to conventional scale are required to be submitted with the Building Permit Application Form. The Homeowner s Building Application Checklist for Constructing a Residential Accessory Building This checklist provides homeowners a summary of the Building Permit submission requirements for constructing

More information

Dispute regarding the venting of a branch drain using an air admittance valve to a building at 122 Remuera Road, Auckland

Dispute regarding the venting of a branch drain using an air admittance valve to a building at 122 Remuera Road, Auckland Determination 2008/32 Dispute regarding the venting of a branch drain using an air admittance valve to a building at 122 Remuera Road, Auckland 1. The matter to be determined 1.1 This is a determination

More information

CHAPTER 3: Modern Methods of Construction (MMC)

CHAPTER 3: Modern Methods of Construction (MMC) CONTENTS 3.1.1 INTRODUCTION 3.1.2 SUITABILITY OF SYSTEMS AND COMPONENTS 3.1.3 TYPES OF MODERN METHODS OF CONSTRUCTION (MMC) 3.1.4 SUITABILITY OF SYSTEMS TO MEET WARRANTY REQUIREMENTS 3.1.5 INSULATED CONCRETE

More information

Installation & maintenance instructions

Installation & maintenance instructions One piece, KD & 2 part cold water storage tanks Installation & maintenance instructions Nicholson Plastics Ltd. GRP Specialist since 1968 Table of contents 1. Guidelines for locating water tanks... 1 2.

More information

Isolation de murs à double paroi Kerndämmung. Regulations. Certificate.

Isolation de murs à double paroi Kerndämmung. Regulations. Certificate. Electronic Copy Knauf Insulation Ltd P O Box 10 Stafford Road St Helens Merseyside WA10 3NS Tel: 01744 24022 Fax: 01744 612007 e-mail: tech@knaufinsulation.com website: www.knaufinsulation.co.uk CI/SfB

More information

Energy Performance Certificate

Energy Performance Certificate Energy Performance Certificate 2, Tree Bank Close, Dwelling type: Detached house RUNCORN, WA7 4TF Date of assessment: 30 August 2008 Date of certificate: Reference number: 31 August 2008 7708-6048-6288-5408-3000

More information

Energy Performance Certificate

Energy Performance Certificate Energy Performance Certificate 140, Pomona Street SHEFFIELD S11 8JL Dwelling type: End-terrace house Date of assessment: 15 October 008 Date of certificate: 15 October 008 Reference number: 9555-85-6803-0698-765

More information

PROCEDURE (Essex) / Linked SOP (Kent) Asbestos Management. Number: U 1005 Date Published: 22 July 2015

PROCEDURE (Essex) / Linked SOP (Kent) Asbestos Management. Number: U 1005 Date Published: 22 July 2015 1.0 Summary of Changes 1.1 This is a new joint procedure/sop for Essex Police and Kent Police. 2.0 What this Procedure is about 2.1 This document identifies how Essex Police and Kent Police shall manage

More information

Energy Performance Certificate

Energy Performance Certificate Energy Performance Certificate 106, St. Marys View, ROTHERHAM, S61 4NJ Dwelling type: Topfloor flat Date of assessment: 13 October 2008 Date of certificate: Reference number: 13 October 2008 81886420500912171092

More information

Energy Performance Certificate

Energy Performance Certificate Energy Performance Certificate 4 Wimbourne Close LLANTWIT MAJOR South Glamorgan CF61 1QW Dwelling type: Date of assessment: Date of certificate: Reference number: Total floor area: Semi-detached house

More information

CHAPTER 9: Building Services

CHAPTER 9: Building Services CONTENTS 9.1 DRAINAGE (BELOW GROUND) 9.2 DRAINAGE (ABOVE GROUND) 9.3 ELECTRICAL INSTALLATIONS 9.4 HEATING AND MECHANICAL SERVICES FUNCTIONAL REQUIREMENTS FUNCTIONAL REQUIREMENTS 9.1 DRAINAGE (BELOW GROUND)

More information

Energy Performance Certificate

Energy Performance Certificate Energy Performance Certificate 36, Farfield Avenue, Beeston, NOTTINGHAM, NG9 2PU Dwelling type: Semidetached house Date of assessment: Date of certificate: Reference number: 80116821667047872026 Total

More information

Energy Performance Certificate

Energy Performance Certificate Energy Performance Certificate 80, Rookwood Avenue, LEEDS, LS9 0NL Dwelling type: Date of assessment: Date of certificate: Reference number: Type of assessment: Total floor area: Midterrace house 84506522769012323996

More information

Energy Performance Certificate

Energy Performance Certificate Energy Performance Certificate 40, Springvale Road SHEFFIELD S10 1LH Dwelling type: Semi-detached house Date of assessment: 6 November 008 Date of certificate: 06 December 008 Reference number: 9154-856-699-038-4495

More information

Jabfill High Performance (HP)

Jabfill High Performance (HP) Jabfill High Performance (HP) Wall insulation full-fill cavity wall insulation Jabfill High Performance (HP) is a BBA-certified cavity-wall insulation system. It is designed to be installed into new masonry

More information

Building Control (Amendment) Regulations MBCA Guidance Document

Building Control (Amendment) Regulations MBCA Guidance Document Building Control (Amendment) Regulations 2014 Contents 1. Introduction 4 2. Legislative Background 5 3. Definitions 6 4. Process 7 5. Documents at tender stage 8 6. Building Control Management System 9

More information

Guidance notes for developers

Guidance notes for developers Guidance notes for developers - adoption of sewers. Section 104 of the Water Industry Act 1991 Foreword These guidelines are designed to be used in conjunction with the current version of Sewers for Adoption

More information

Energy Performance Certificate

Energy Performance Certificate Energy Performance Certificate 15, Froude Avenue, TORQUAY, TQ2 8NS Dwelling type: Date of assessment: Date of certificate: Reference number: Type of assessment: Total floor area: Detached bungalow 23689963626060911070

More information

Drainage installation: introduction

Drainage installation: introduction Drainage installation: introduction If there s one area of a new build project where the expression once it s in, there is no going back applies, it s the drainage system. Drainage is one of the first

More information

Energy Performance Certificate

Energy Performance Certificate Energy Performance Certificate 3 The Windsors BUCKHURST HILL Essex IG9 6DJ Dwelling type: Date of assessment: Date of certificate: Reference number: Total floor area: Semi-detached house 05 April 2009

More information

Product Guide low tolerances high quality

Product Guide low tolerances high quality Building the future with Ytong autoclaved aerated concrete Product Guide low tolerances high quality Introduction Distinctive building with aerated concrete Ytong blocks are a well known global name for

More information

Energy Performance Certificate

Energy Performance Certificate Energy Performance Certificate Crofters Guest House Dwelling type: Semi-detached house 9 Oxford Hill Date of assessment: 16 April 010 WITNEY Date of certificate: 16 April 010 OX8 3JU Reference number:

More information